all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
Manual | Users Manual | 5.68 MiB | April 12 2022 / October 09 2022 | delayed release | ||
1 2 |
|
Packaging Label | Users Manual | 331.53 KiB | April 12 2022 / October 09 2022 | delayed release | ||
1 2 |
|
Internal Photos | Internal Photos | 488.01 KiB | April 12 2022 / October 09 2022 | delayed release | ||
1 2 |
|
External Photos | External Photos | 503.16 KiB | April 12 2022 / October 09 2022 | delayed release | ||
1 2 |
|
Label | ID Label/Location Info | 84.17 KiB | April 12 2022 / April 13 2022 | |||
1 2 | Authorization Letter | Cover Letter(s) | 30.53 KiB | March 11 2024 | ||||
1 2 | Confidentiality Letter | Cover Letter(s) | 758.34 KiB | March 11 2024 | ||||
1 2 | Declaration Letter | Attestation Statements | 62.33 KiB | March 11 2024 | ||||
1 2 | PCII Change Request Letter | Cover Letter(s) | 20.61 KiB | March 11 2024 | ||||
1 2 | RF Exposure Report | RF Exposure Info | 330.05 KiB | March 11 2024 | ||||
1 2 | Schematics | Schematics | March 11 2024 | confidential | ||||
1 2 | Test Report | Test Report | 771.94 KiB | March 11 2024 | ||||
1 2 | Test Setup Photos | Test Setup Photos | March 11 2024 / September 08 2024 | delayed release | ||||
1 2 | US Agent | Attestation Statements | 206.06 KiB | March 11 2024 | ||||
1 2 |
|
FCC Declaration Letter | Cover Letter(s) | 2.26 MiB | April 12 2022 / April 13 2022 | |||
1 2 |
|
MPE Report | RF Exposure Info | 406.56 KiB | April 12 2022 / April 13 2022 | |||
1 2 |
|
Power of Attorney Letter | Cover Letter(s) | 189.32 KiB | April 12 2022 / April 13 2022 | |||
1 2 |
|
test setup photo | Test Setup Photos | 279.96 KiB | April 12 2022 / October 09 2022 | delayed release |
1 2 | Manual | Users Manual | 5.68 MiB | April 12 2022 / October 09 2022 | delayed release |
DeLaval BioSensors ear tag BAT1 Instruction Book DeLaval 2022. 2022-03-25, Version 7 2800012301 Original instruction Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Table of contents EU Declaration of Conformity - DeLaval BioSensors ear tag BAT1............................................... 5 Safety precautions.............................................................................................................................. 7 n DeLaval BioSensors ear tag BAT1 4.1 4.2 Foreword........................................................................................................................... 7 1 2 Disclaimer......................................................................................................................... 7 Precautionary statements................................................................................................. 7 3 Safety regulations............................................................................................................. 8 4 Safety regulations - General............................................................................. 8 Safety regulations - Operating the equipment.................................................. 9 5 Safe and healthy work routines......................................................................................... 9 6 Compliance with national regulations for the ear tag BAT1............................................ 10 7 Regulatory compliance.................................................................................................... 13 8 Warranty.......................................................................................................................... 13 9 Disposal.......................................................................................................................... 13 General description........................................................................................................................... 15 n DeLaval BioSensors ear tag BAT1 1 Introduction of the BioSensors ear tag BAT1.................................................................. 15 2 Overview of the BioSensors ear tag BAT1...................................................................... 16 Technical data for the BioSensors ear tag...................................................................... 17 3 Planning.............................................................................................................................................. 20 n DeLaval BioSensors ear tag BAT1 1 Requirements for the BioSensors ear tag BAT1............................................................. 20 Installation.......................................................................................................................................... 21 n DeLaval BioSensors ear tag BAT1 1 Connecting the BioSensors ear tag to the cow ID in DelPro Companion....................... 21 2 Attaching the BioSensors ear tag to the animal's ear..................................................... 27 3 Removing the BioSensors ear tag from the animal's ear................................................ 30 DeLaval 2022. 2022-03-25, Version 7 3 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Table of contents DeLaval 2022. 2022-03-25, Version 7 4 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. EU Declaration of Conformity Name of product:
DeLaval BioSensors ear tag BAT1 Type/model:
Report No. BAT1 D0000117103 The product complies with requirements of the following directives:
Radio equipment directive RED 2014/53/EU Restriction of the use of certain hazardous substances (RoHS) - 2011/65/EU Harmonized standards which have been used or parts thereof:
ETSI EN 301 489-1 V2.2.3 ETSI EN 301 489-3 V2.1.1 ETSI EN 301 489-33 V2.2.1 EN IEC 63000:2018 Other technical standards and specifications used:
EN 62368-1:2014 This declaration of conformity is issued under the sole responsibility of the manufacturer. Tumba 2021-09-08 Signed:
Name:
Magnus Berg Position:
Executive Vice President Department:
Product Management & Develop-
ment Person authorised to compile the technical file:
Product Manager P.O. Box 39 SE 147 21 TUMBA Sweden DeLaval 2022. 2022-03-25, Version 7 5 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. Name and address of manufacturer:
DeLaval International AB P.O. Box 39 SE 147 21 TUMBA Sweden DeLaval 2022. 2022-03-25, Version 7 6 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions Safety precautions DeLaval BioSensors ear tag BAT1 1 Foreword The safety and operating instructions must be observed by any person involved with the use or operation of this equipment. Under no circumstances must the equipment be used if it is damaged or if the operation of the equipment is not completely understood. 2 Disclaimer The information, instructions and parts listed are applicable and up-to-date when issued. DeLaval reserves the right to make changes without notice. 3 Precautionary statements Precautionary statements are safety-related warning messages intended to prevent the incor-
rect or hazardous use of equipment, machinery or software. The following list defines the different types of precautionary statements used in DeLaval doc-
umentation:
Danger: Refers to an imminent and severe risk. Failure to comply with the instruction will result in serious injury or death. Warning: Refers to a potential but severe risk. Failure to comply with the instruction may result in injury or death. Caution: Refers to a limited risk. Failure to com-
ply with the instruction may result in minor injury. Mandatory: Refers to an action or behaviour that is essential to a safe and proper use of the equip-
ment. Prohibited: Refers to an action or behaviour that is incompatible with a safe and proper use of the equipment. DeLaval 2022. 2022-03-25, Version 7 7 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions Note! Indicates important information related to a situation or behaviour where a non-immediate or potential hazard presents a risk of damage to property or equipment. This symbol indicates risk of injury. This symbol indicates risk of electric shock. Refer to ISO 7010 for other symbol definitions. 4 Safety regulations 4.1 Safety regulations - General Warning!
Intended use Do not use the equipment for any other purposes than the intended use. Warning!
Risk of injury The system must only be operated by an instructed or skilled person. Ordinary persons must keep out of the working area. Mandatory!
Read the instructions carefully before using the equipment. Contact a DeLaval representative if the instructions are not understood. Compliance with these instructions ensures the correct and safe use of the equipment. Keep the instructions for future reference. DeLaval 2022. 2022-03-25, Version 7 8 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions Prohibited!
Do not use inadequate parts or consumables Using products that do not meet the specified requirements, such as spare parts or consumables, may result in damage or injury and may void or limit the warranty. 4.2 Safety regulations - Operating the equipment Caution!
Risk of infection Bacterias and viruses may give the animal infections. Before inserting the ear tag: Always desinfect the animal ear, the
"DeLaval BioSensors ear tag BAT1", its backplate and any tool used. Contact the veterinary if the animal shows signs of infection. 5 Safe and healthy work routines n Ensure that the area is well lit. n Keep the floor dry to avoid slipping. n Wear protective clothing and appropriate shoes or boots. DeLaval 2022. 2022-03-25, Version 7 9 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions 6 Compliance with national regu-
lations for the ear tag BAT1 4 4 9 1 9 2 Fig. 1: The packaging of the "Ear tag BAT1" and its regulatory compliance marking. A:
CE - "conformit europenne". The CE-mark on the type plate indicates that the parlour fulfils the European regulations for products. The declaration by the manufacturer states the directives that are fulfilled. The Waste Electrical and Electronic Equip-
ment Directive (WEEE Directive). C: UK Conformity Assessed (UKCA) mark. D: Requirement to read the instruction book B:
before use of the ear tag. E:
F:
G:
H:
FCC ID: UCSBAT1. IC: 6576A-BAT1. The DeLaval adress. China RoHS. FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. DeLaval 2022. 2022-03-25, Version 7 10 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.AAGFEDCBICICH DeLaval BioSensors ear tag BAT1 Safety precautions Caution!
Changes and modifications not expressly approved by DeLaval can void your authority to operate this equipment under Federal Communi-
cations Commission rules. Note! This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a com-
mercial environment. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radiocommunications. Operation of this equip-
ment in a residential area is likely to cause harm-
ful interference in which case the user will be required to correct the interference at his own expense. Radiation Exposure Statement:The device complies with the requirements set forth in CFR 47 Sections 2.1093 for an uncontrolled environ-
ment. ISED Compliance Statement This device contains license-exempt transmit-
ter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
n This device may not cause interference. n This device must accept any interference, including interference that may cause unde-
sired operation of the device. Caution!
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Radiation Exposure Statement: This equip-
ment complies with IC RSS-102 radiation expo-
sure limits set forth for an uncontrolled DeLaval 2022. 2022-03-25, Version 7 11 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions environment. This equipment should be installed and operated with minimum distance 5 mm between the radiator and your body. CE Compliance Statement The manufacturer, Delaval (Gustaf de Lavals vg 15, 147 41 Tumba, Sweden), declares that the product DeLaval BioSensors ear tag BAT1 is conform to the following Directives and stand-
ards:
n 2014/53/EU (Radio Equipment Directive) Article 3.1a: Safety and Health. n IEC 62368-1: 2020 n EN 50566: 2017 n EN 62479: 2010 n IEC/IEEE 62209-1528:2020 Article 3.1b:
EMC n CISPR 32:2015+AMD1:2019 n EN 301 489-1 V2.2.3: 2019-11 n EN 301 489-33 V2.2.1: 2019-04 n EN 61000-4-3: 2020 n EN 61000-4-4: 2012 n EN 61000-4-6: 2014 n Article 3.2: RF spectrum efficiency EN 302 065-2 V2.1.1: 2016-11 2011/65/EU (RoHS) n IEC 63000:2016 This declaration of conformity is issued under the exclusive responsibility of the manufacturer. China SRRC Compliance Statement Manufacturer: DeLaval Product number: BAT1 CMIIT ID: XXXXYYZZZZ The use of ultra-wideband (UWB) equipment on aircraft is prohibited. The use of ultra-wideband (UWB) radio transmit-
ting equipment is prohibited within 1 km around the radio astronomy station site listed in the foot-
note "CHN12" of the "Regulations on Radio Fre-
quency Allocation of the People's Republic of China". When the ultra-wideband (UWB) radio transmit-
ting equipment is used, it shall not cause radio interference to the stations of other radio serv-
ices, and shall not propose interference protec-
tion requirements to the stations of other radio services. DeLaval 2022. 2022-03-25, Version 7 12 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions 7 Regulatory compliance For more information on regulatory compliance, see https://corporate.delaval.com/product-and-
material-compliance/. 8 Warranty Note! DeLaval will not take any responsibility for damage resulting from faulty installation, opera-
tion, or for improper or inadequate care and maintenance. Note! DeLaval will not take any responsibility for any damage resulting from frost. The owner/user must take the necessary measurements to pre-
vent the ambient temperature around the equip-
ment from dropping to or below freezing point. Note! Modification may create risks not covered by the original construction. Do not make any modifications which has not been approved by DeLaval. 9 Disposal When the product reaches end of life, dispose it properly in accordance with local laws and regu-
lations. Disposal of the packaging material
(EU directive 94/62/EC) This symbol indicates that the products packaging material can be recycled. Disposal of electrical and electronic equip-
ment with or without battery WEEE European Directive 2012/19/EU European Battery Directiv 2006/66/EC The symbol with a crossed-out wheelie bin on the product or its packaging indicates that the equip-
ment is electric waste, with or without a battery. The product shall not be disposed with household waste. DeLaval 2022. 2022-03-25, Version 7 13 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Safety precautions A horizontal bar beneath the bin means that the product is manufactured after August 13, 2005. To prevent inappropriate waste handling of this product, and its negative consequences on the environment and human health, all products shall be disposed of accordance with local laws and regulations. Hand it over to an official recycling facility, or use a battery disposal facility when available. Please contact the local municipal office for infor-
mation on the nearest recycling station. DeLaval 2022. 2022-03-25, Version 7 14 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 General description General description DeLaval BioSensors ear tag BAT1 1 Introduction of the BioSensors ear tag BAT1 The ear tag is part of the DeLaval BioSensors behaviour analysis system. Fig. 2: The ear tag and its backplate. The ear tag is attached to an animal's ear and communicates with "Pozyx Anchor PoE+". 8 9 6 4 8 2 1 0 7 4 8 2 Fig. 3: "Pozyx Anchor PoE+". DeLaval 2022. 2022-03-25, Version 7 15 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 General description 2 Overview of the BioSensors ear tag BAT1 8 9 2 5 8 2 Fig. 4: The BAT1 (the tag with the DeLaval logo) on the animal's ear. The top framed illustration shows the plier used to attach the BAT1 and its backplate to the ear. DeLaval 2022. 2022-03-25, Version 7 16 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.1234 DeLaval BioSensors ear tag BAT1 General description 6 9 2 5 8 2 7 8 3 5 8 2 Fig. 5: The plier with the BAT1 and its backplate. The backplate is fastened on the plier's nib (1). The plier's springing piece shall be tilted (2) and the BAT1 inser-
ted under the springing piece (3). The HHR5000 is used when connecting the BAT1 to the cow card in the app DeLaval DelPro Companion. From part A of the HHR, the animal's ISO/B transponder is read, which opens the cow card in the app DelPro Companion. From part B of the HHR the BAT1 is read and is connected to the cow card in the app DelPro Companion. The handheld reader's battery (C) is rechargable and is within its handle. Fig. 6: The DeLaval handheld reader HHR5000. 3 Technical data for the BioSen-
sors ear tag DeLaval 2022. 2022-03-25, Version 7 17 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.123FFABC DeLaval BioSensors ear tag BAT1 General description A digital accelerometer within the ear tag pro-
vides data to the ancors every 2.2 seconds. The ear tag can be out of range of an anchor for up to 15 hours, but sends all its collected data to the anchor when it is within the anchor's range again. 9 9 6 4 8 2 Fig. 7: The dimensions of the ear tag (in millimeter). DeLaval 2022. 2022-03-25, Version 7 18 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.2264544430 DeLaval BioSensors ear tag BAT1 General description The lithium battery within the ear tag is non-
chargeable and it is not possible to replace it. An ear tag should be replaced after the battery life-
time which is five years. Battery power 3.6 volt and 1.2 ampere-hour (internal non-replaceable, non rechargeable battery). Battery type ER14250 Power consumption The average power consumption is 20 microampere. Environment The ear tag is positioned on an animal's ear. The animal can be walking outdoors or inside a barn. Weight
< 30 gram Operating temperature 0 to +55 C Recommended storage temperature
+5 to +35 C Relative humidity 10-100 % relative humidity (RH) Ear tag lifetime 5 years Radio technical data of the ear tag Suported UWB Channels 5 Center frequency Bandwith 6489.6 MHz 500 MHz Frequency band 6240-6739.2 MHz Data Rate 6.81 Mbps Transmit power density
-41.3 dBm / MHz DeLaval 2022. 2022-03-25, Version 7 19 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Planning Planning DeLaval BioSensors ear tag BAT1 1 Requirements for the BioSen-
sors ear tag BAT1 n The minimum age of the animal at the time of tagging should be 12 months. n Examine the barn environment for objects that could rip an ear tag from an animal. Take note of sharp edges or hooks, espe-
cially on the headlocks. DeLaval 2022. 2022-03-25, Version 7 20 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Installation Installation DeLaval BioSensors ear tag BAT1 1 Connecting the BioSensors ear tag to the cow ID in DelPro Com-
panion 5 9 2 5 8 2 Fig. 8: Connection of the BioSensors ear tag to the cow ID in DelPro Companion. DeLaval 2022. 2022-03-25, Version 7 21 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.F DeLaval BioSensors ear tag BAT1 Installation 1. Attach the mobile phone to the handheld reader. 2. Power on the handheld reader by pressing
. its power button 9 9 2 5 8 2 1 7 4 5 8 2 5 0 1 1 7 2 Fig. 9: The handheld reader with the mobile phone. Fig. 10: The window for Bluetooth activation and pairing in a mobile phone. Fig. 11: QR code to the DeLaval apps. 3. Open the Bluetooth settings on the mobile phone and pair the mobile phone with the handheld reader. 4. Register and log into DelPro Companion. If you don't have DelPro Companion on your mobile phone then follow step 5 or 6. Otherwise, continue with step 7. Android mobile phone 5. Download DelPro Companion for Android from https://play.google.com/store/apps/
developer?id=DeLaval+International+AB. DeLaval 2022. 2022-03-25, Version 7 22 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.F DeLaval BioSensors ear tag BAT1 Installation Fig. 12: QR code to DelPro Companion. Apple iOS mobile phone 6. Download DelPro Companion for Apple iOS from https://itunes.apple.com/app/
id1440785421. 7. In DelPro Companion, go to "Settings RFID Reader" and then activate the usage of RFID reader. Choose the handheld reader HHR5000. Fig. 13: The window for RFID reader in a mobile phone. 8. Point the handheld reader towards the ani-
mal's transponder and press the hand-
held's main button
. When the transponder is read, the ani-
mal's cow card is automatically shown in "DelPro Companion". Fig. 14: Reading of a transponder. 5 3 6 0 8 2 3 7 4 5 8 2 4 9 2 5 8 2 DeLaval 2022. 2022-03-25, Version 7 23 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.F41231234 DeLaval BioSensors ear tag BAT1 Installation 9. Swipe to the last page of the cow card. Fig. 15: DelPro Companion. 10.Tap the ear tag symbol. 2 5 6 5 8 2 1 6 6 5 8 2 Fig. 16: DelPro Companion. DeLaval 2022. 2022-03-25, Version 7 24 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Installation 11.Tap the "+" symbol. Fig. 17: DelPro Companion. 12.The DelPro Companion software asks to scan the ear tag. 2 6 6 5 8 2 3 6 6 5 8 2 Fig. 18: DelPro Companion. DeLaval 2022. 2022-03-25, Version 7 25 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Installation 13.Hold the ear tag close to the handheld reader as shown in the illustration. Fig. 19: Holding the ear tag close to the handheld reader. 14.A message is displayed when the ear tag has been connected to the cow card and the ear tag is activated. 5 9 2 5 8 2 4 6 6 5 8 2 Fig. 20: DelPro Companion. DeLaval 2022. 2022-03-25, Version 7 26 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.F DeLaval BioSensors ear tag BAT1 Installation 2 Attaching the BioSensors ear tag to the animal's ear General Danger!
To avoid injuries: protect yourself during the entire tagging process Wear protective clothing, shoes or boots. Make sure that the animal is calm and that it is surrounded by calm people. Make sure never to stand in a posi-
tion so that you or anyone else can be squeezed or harmed if the animal moves. Note! Protection from animal injuries Keep the animal still during tagging to avoid that the ear is wounded. To reduce the risk for infection, tag when the weather is cool and disinfect the ear as follows:
Clean it with 0.015% Chlorine solution, 1-2%
Chlorhexidine solution or 5% Iodine solution. If the tag was used on another animal or is con-
taminated with organic material, then do the fol-
lowing:
Clean the tag with water and detergent. Dry the tag. Cleaned and new tags and backplates shall be disinfected before use with 0.015% Chlorine sol-
ution, 1-2% Chlorhexidine solution or 5% Iodine solution. Daily check the tagged ear for signs of infection during the first week after tagging. Then check the tagged ear during normal animal care, for as long as the animal wears the ear tag. Consult a veterinarian directly if pain, redness or swelling appears on the animal's ear. Do not attach the ear tag to animals younger than 12 months. Let the ear tag be at barn temperature one hour before the attachment to the animal's ear. The ear tag material might break during the attach-
ment if it is too cold. DeLaval 2022. 2022-03-25, Version 7 27 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval BioSensors ear tag BAT1 Installation Deciding on which ear and where on the ear to place the ear tag The ear tag can be placed in either the left or the right ear. Keep the number of tags per ear as low as pos-
sible, for the animal's wellbeing. The ear tag will not interfere with an RFID tag, but for weight reasons, it is recommended to place it together with the number tag. Place the ear tag on the inner side of other tags but not at the inner of the ear. Leave at least 0.5 cm of space between tags, for ventilation and proper wound healing. The ear tag shall be attached where there is no blood vessel or cartilage tissue (red in the illus-
trations below). DeLaval 2022. 2022-03-25, Version 7 28 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.1/21/41/21/41234 DeLaval BioSensors ear tag BAT1 Installation Special tool:
n Ear tagger Materials:
n Disinfectant such as 0.015% Chlorine solu-
tion, 1-2% Chlorhexi-
dine solution or 5%
Iodine solution 1. Clean the site by removing debris and wip-
ing the site with the disinfectant. 2. Clean both sides of the animal's ear with the disinfectant and let the ear dry. 3. Note! In order not to injure the animal, ensure that the ear tagger is functioning correctly. The ear tagger's pin must not be bent. In that case, the pin has to be exchanged. Tilt the ear tagger's spring clip (2) and fas-
ten the ear tag (3) under the clip. Fasten the backplate (1) and make sure that the ear tagger's pin goes all the way into the bottom of the backplate. 6 9 2 5 8 2 Fig. 21: The ear tagger's spring clip (2) with the ear tag (3) and its backplate (2). DeLaval 2022. 2022-03-25, Version 7 29 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.123 DeLaval BioSensors ear tag BAT1 Installation 4. Dip the ear tagger with the ear tag and its backplate into a disinfectant such as 0.015% Chlorine solution, 1-2% Chlorhex-
idine solution or 5% Iodine solution. Note! If the ear tagger, the ear tag or its backplate gets in contact with organic material you have to do the following:
Clean them with water and detergent. Dry them. Repeat the dipping in 0.015% Chlor-
ine solution, 1-2% Chlorhexidine sol-
ution or 5% Iodine solution. 5. Place the ear tagger over the ear from the ears bottom side. 6. When the animal holds still: Squeeze the ear tagger quick and firm until you hear a click. There will be a click when the ear tag and backplate are connected. 7. Take the ear tagger away from the cow. 8. Check the tagged ear for signs of infection daily during the first week. Consult a veterinarian directly if pain, red-
ness or swelling appears on the tagged ear. 7 9 2 5 8 2 Fig. 22: Dipping the ear tagger with the attached ear tag and backplate into disinfectant. 3 Removing the BioSensors ear tag from the animal's ear Remove the ear tag from the animal's ear with a pair of scissors, wire cutters or a detagging tool
(e.g. NEW Z Tags Multi-Cutter, article number 2150018671). Cut the backplate of the ear tag from the back of the ear. The ear tag can be reused. Before reuse, it must be disinfected with 0.015% Chlorine solution, 1-2% Chlorhexidine solution or 5% Iodine solu-
tion. This to avoid the spread of bacteria or viru-
ses. DeLaval 2022. 2022-03-25, Version 7 30 (32) 2800012301 Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. is a registered trademark of Tetra Laval Holdings & Finance S. A. and DeLaval is a registered trade/service mark of DeLaval Holding AB. Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window. DeLaval International AB Box 39 SE-147 21 Tumba SWEDEN www.delaval.com Preliminary941322_VMS Instruction Book 2006.pdf2009-09-07No.NameRangeDefaultDescription/optionsNo.NameRangeDefaultDescription/options0 = no acidic cleaning0 = no acidic cleaning1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning3 = etc.3 = etc.Maintenance an calibrationThe following points are important to sustaincorrect dosing of etergents. Note thatthese two tasks should be performed by anauthorised DeLaval service engineer.The tubes in the peristaltic pumps shouldbe replaced at least two times a year.The dosing volume (P6-P8) of thedetergent pumps should be checkedevery third month. The dosing capacity(P32-P34) may need to be adjusted.Starting cleaning or rinsingfrom the touch screenNote: Any ongoing backflush process mustfirst be finished before cleaning or rinsingcan be started.1. Ensure that the milking station is inmanual mode.2. Remove any cow that might be in themilking station.After treatment windowNote: Both gates should be closed toprevent a cow from entering before thesystem cleaning has been started. Closingand opening gates is done in the Stallcontrol window.3. Press the tab After Treatment on thetouch screen to display the After treatmentwindow.4. In the After treatment window, press theCleaning and Rinsing button. This will openthe Cleaning and rinsing window.
1 2 | Internal Photos | Internal Photos | 488.01 KiB | April 12 2022 / October 09 2022 | delayed release |
1 2 | External Photos | External Photos | 503.16 KiB | April 12 2022 / October 09 2022 | delayed release |
1 2 | Label | ID Label/Location Info | 84.17 KiB | April 12 2022 / April 13 2022 |
Note 4 Note 5 0 3 A3 64 54 44 f o t r a p e h t n o n o i t a g i l b o l a u t c a r t n o c e h t o t y n o B A l l a n o i t a n r e t n I l a v a L e D a e t u t i t s n o c y a m t n e m u c o d s h T i
. n o p u d e e r g a y s s e r p x e t n e t x e l
, 7 2 1 2 2
, 1 0 5 y t r a p d r i h t y n a o t d e s o c s d r o d e t t i i l m s n a r t
, d e c u d o r p e r i
, d e p o c e b t o n t s u m s t n e t n o c s t i d n a t n e m u c o d s h T i
. B A l a n o i t a n r e t n I l a v a L e D f o t n e s n o c e h t t u o h t i w
. 8 1 0 2 B A l a n o i t a n r e t n I l a v a L e D I T H G R Y P O C Note 7 Laser etched 5 Note 8 Laser etched Note 3 Laser etched 3x 9 0 0,5 1 T A B S C U
D I C C F 1 5 8 6 1 0 0 5 1 2 D D M Y 1 T A B
, 5 2 0 3 4 0,25 4 0,25 20 0,25 5
, 5 2 0 9 5
, 15,4 0,25 5 0,1 4 0,25 Title BAT Ear Tag Complete First angle projection Method ISO E Sheet No. 2 No. of sheets 2 Version 05 Document No. D0000100697
1 2 | FCC Declaration Letter | Cover Letter(s) | 2.26 MiB | April 12 2022 / April 13 2022 |
SGS North America Inc. " 5 620 Old Peachtree Road Applicant Declaration SUITE 100 Suwanee, Georgia 30024 United States DeLaval International AB Gustaf de Lavals vag 15 Tumba 14637 Sweden Susanne Sundstroem compliance@delaval.com
+46734131404
|, the undersigned, certify that | am an authorized signatory for the Applicant and therefore declare;
a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for:
(1) labeling the equipment with the exact FCC ID as specified in this application,
(2) compliance statement labeling pursuant to the applicable rules,
(3) compliance of the equipment with the applicable technical rules, c) ifthe Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCCs technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with 1SO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements.
(1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing.
(2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED.
(3) the Applicant shal/, upon request by SGS, at the Applicants expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a party for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: hittps://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-reaulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https:/Awww.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html eo Applicant Signature:
oe oe ae ae gf we Teamleader Product Compliance . NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Applicant Declaration Rev:0.0
1 2 | Power of Attorney Letter | Cover Letter(s) | 189.32 KiB | April 12 2022 / April 13 2022 |
DeLaval International AB Date: 2022-01-31 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: UCSBAT1 To whom it may concern:
We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch and Kobe Jian in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). |
Where our agent signs the application for certification on our behalf, | acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with DeLaval International AB. This authorization is valid until further written notice from the applicant. Print Name: Susanne Sundstroem Title: Team Leader, Product Compliance aed oe Signature:
wo 4 Stas Z es On behalf of Company: DeLaval International AB So Telephone: +46734131404 E-mail: compliance@delaval.com
1 2 | test setup photo | Test Setup Photos | 279.96 KiB | April 12 2022 / October 09 2022 | delayed release |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2024-03-11 | 6489.6 ~ 6489.6 | WBT - Wideband Transmitter | Class II permissive change or modification of presently authorized equipment |
2 | 2022-04-13 | 6489.6 ~ 6489.6 | WBT - Wideband Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2024-03-11
|
||||
1 2 |
2022-04-13
|
|||||
1 2 | Applicant's complete, legal business name |
DeLaval International AB
|
||||
1 2 | FCC Registration Number (FRN) |
0015169949
|
||||
1 2 | Physical Address |
Gustaf de Lavals vag 15, 14641 Tumba, SWEDEN
|
||||
1 2 |
39
|
|||||
1 2 |
Tumba, N/A 14621
|
|||||
1 2 |
Tumba, N/A
|
|||||
1 2 |
Sweden
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 2 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
UCS
|
||||
1 2 | Equipment Product Code |
BAT1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
S**** S****
|
||||
1 2 | Title |
Product Compliance
|
||||
1 2 | Telephone Number |
+4673********
|
||||
1 2 | Fax Number |
+4685********
|
||||
1 2 |
c******@delaval.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 2 | Name |
K****** X****
|
||||
1 2 |
K**** J********
|
|||||
1 2 | Physical Address |
No.1 Workshop, M-10, Middle Section Science & Tech
|
||||
1 2 |
No.198 Kezhu Road
|
|||||
1 2 |
Shenzhen, 518057
|
|||||
1 2 |
Guangzhou, Guangdong, 510663
|
|||||
1 2 |
China
|
|||||
1 2 | Telephone Number |
+8675********
|
||||
1 2 |
86-20********
|
|||||
1 2 | Fax Number |
N/A********
|
||||
1 2 |
K******@sgs.com
|
|||||
1 2 |
K******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
1 2 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 2 | Name |
K******** X******
|
||||
1 2 | Physical Address |
No.1 Workshop, M-10, Middle Section Science & Tech
|
||||
1 2 |
Shenzhen, 518057
|
|||||
1 2 |
China
|
|||||
1 2 | Telephone Number |
+8675********
|
||||
1 2 | Fax Number |
N/A********
|
||||
1 2 |
K******@sgs.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 09/08/2024 | ||||
1 2 | 10/09/2022 | |||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | WBT - Wideband Transmitter | ||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Biosensors ear tag | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Class II permissive change or modification of presently authorized equipment | ||||
1 2 | Original Equipment | |||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Permissive change as specified under 47 CFR 2.1043 of the FCC rules to the certified device FCC ID: UCSBAT1. Change of the battery buffering capacitors from 100uF to 22uF and performed Radiated Spurious Emissions and EIRP test for this change. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd. Sh
|
||||
1 2 |
SGS-CSTC Standards Technical Services Co., Ltd.
|
|||||
1 2 | Name |
K**** X****
|
||||
1 2 |
K**** J********
|
|||||
1 2 | Telephone Number |
+86 (********
|
||||
1 2 |
86-0-********
|
|||||
1 2 |
K******@sgs.com
|
|||||
1 2 |
k******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.250 | 6489.60000000 | 6489.60000000 | |||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15.250 | 6489.60000000 | 6489.60000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC