2024/1/15 17:10 Temperature & Humidity Monitor | Roombanker wiki Environmental Monitoring Sensor Temperature Humidity Monitor Specification Temperature & Humidity Monitor Download Spec Last update: January 12th, 2024. A compact and exquisite temperature and humidity monitor to accurately track your indoor temperature and humidity changes. It supports both Fahrenheit and Celsius versions. 1. Detection Performance Temperature Range and Accuracy From -10 to +55 Accuracy at 0.5 Humidity Range and Accuracy From 0 to 99%RH Accuracy at 5%
https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification 1/5 2024/1/15 17:10 Temperature & Humidity Monitor | Roombanker wiki 2. Features Centigrade and Fahrenheit Support unit switching between Centigrade and Fahrenheit Depends on sales region. Remote setting and testing Setting and testing from RB Link App Advanced features Power up enrolling When T&H monitor is powered up, it will automatically start paring to the hub nearby Find me When enabled, the T&H monitor starts flashing green, which can help identify the monitor from numerous devices. Signal strength detection When enabled, T&H monitor starts flashing green/orange/red showing the wireless signal strength between the hub at current installation site. Low battery notification 3. RBF wireless technology Wireless signal range Up to 1,900 m in an open space with hub Two-way communication with hub https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification 2/5 2024/1/15 17:10 Temperature & Humidity Monitor | Roombanker wiki Frequency bands 868 MHz Monitor: 863 ~ 870 MHz 915 MHz Monitor: 902 ~ 928 MHz Depends on sales region. Wireless signal modulation FSK / DSSS Encrypted communication All the data transmitted are protected by AES-CCM encryption with a random key. Frequency hopping (FHSS) To prevent radio interference and radio signal interception. Time division multiple access (TDMA) With the help of clock synchronization technology, hub will slice time into different division for different RBF wireless devices. In this way, all devices will communicate with hub in a sequence. 4. Electrical Characteristics Power Supply AA Battery 3 Up to 5 years (standby mode) 5. General https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification 3/5 2024/1/15 17:10 Temperature & Humidity Monitor | Roombanker wiki Operation Temperature From -10 to +55 (14F to 131F) Operation Humidity From 0% to 99%
Storage Temperature From -20C to 60C (-4F to 140F) Dimension(WxHxD) 64mm 64mm 28mm Weight 68.5 g 6. Compatibility Operates with all Roombanker Home Security Hubs, RBF repeaters. 7. Complete set Product Quantity Temperature Humidity Monitor 1 AA Battery Quick Start Guide 3 1 https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification 4/5 2024/1/15 17:10 Temperature & Humidity Monitor | Roombanker wiki 8. Additional information Available models RBSS-TH1-868 RBSS-TH1-915 Certifications CE, CB FCC ICASA RCM NOM Anatel Warranty Replacement and repair within 24 months of the date of sale. Batteries are not covered under warranty. https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification 5/5 FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.