ClareOne Door/Window Sensor Installation Sheet Installation The door/window sensor can be installed using the provided adhesive or screws. Mounting orientation The sensor and magnet should be placed near the top of the door with the sensor attached to the unmoving part of the closure. For example, attach the main body of the sensor to the door frame, not the door. We recommend that the sensor is placed in the top corner of the opening side of the door, see Figure 1. Figure 1: Sensor orientation The sensor and magnet each have a slightly engraved line. This line denotes where the sensors align to function properly. If the sensor and magnet, when together/closed, do not line up, the sensor will not report correctly. See Figure 2, on page 2. Part number:
ClareOne Door/Window Sensor, White (CLR-C1-DW-W) ClareOne Door/Window Sensor, Brown (CLR-C1-DW-B) Description The ClareOne Door/Window Sensor is a magnetic sensor device designed to fit seamlessly alongside a door frame or window frame. When the door or window is opened, the magnetic contact is disrupted, and then the sensor transmits an alarm notification to the ClareOne panel. Important safety instructions Before you install this sensor, be sure to:
Read, keep, and follow all instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat. Do not expose the device to water. When there is a low battery, replace with a compatible lithium ion battery. 25AUG23 Snap One, LLC. 1 / 5 DOC ID 1897 Rev 03 Figure 2: Sensor alignment 3.1.c (Optional) Mark the screw hole locations, then using a power drill, drill holes and install the 2 provided wall anchors. 3.1.d Remove the adhesive film cover. To install the door/window sensor:
1. Select the desired position for the sensor and magnet. Notes The sensor and magnet must be within 0.25 inches of each other on final installation. See Table 1, on page 4 for different gap ranges on metallic and non-metallic mounting surfaces. Verify that the sensor and magnet are aligned correctly. See Figure 2, on page 2. 2. Remove the sensors battery pull tab. 3.1.e Place the back plate against the door frame/window frame, making sure that the orientation is correct for the desired position. Note: Once the adhesive is secure, the sensor cannot be moved. 3.1.f Insert the first screw into the non-breakaway screw hole, and then use a screwdriver to partially secure the screw in the wall. Do not fully insert the screw until the second screw has secured the sensors position. 3. Adhere the sensor to the wall using the provided screws or adhesive. 3.1.g Insert a second screw into the breakaway screw hole, and then partially secure in the wall. Note: We recommend using the provided screws for installation. This method is more secure than using adhesive alone. Sensor screws 3.1.a Locate the bottom of the sensor (the slotted short end). 3.1.b Turn the sensor over, then gently slide a fingernail/fingertip into the slot pushing the sensors back plate up and away from the sensor body. 3.1.h Observe the sensor position. When satisfied with the position, use a screwdriver to fully secure each screw in the wall. 3.1.i Press the front of the sensor against the base until there is an audible snap. 25AUG23 Snap One, LLC. 2 / 5 DOC ID 1897 Rev 03 Sensor adhesive 3.2.a Select the desired position for the sensor. 3.2.b Peel one side of the adhesive tape, and then press the tape firmly against the sensor. Note: Once the adhesive is secure, the sensor cannot be moved. 3.2.c Peel the other side of the adhesive, and then press the sensor against the wall. 4. Line the magnet up with the sensor, verifying that they align properly, and then adhere the sensor to the wall using the provided screws or adhesive. Magnet screws 4.1.a Locate the bottom of the magnet (the slotted short end). 4.1.b Turn the magnet over, and then gently slide a fingernail/fingertip into the slot pushing the magnets back plate up and away from the magnet body. 4.1.c (Optional) Mark the screw hole locations, then using a power drill, drill holes and install the 2 provided wall anchors. 4.1.d Remove the adhesives film cover, and then place the back plate against the door/window, making sure that the orientation and alignment are correct for the desired position. Note: Once the adhesive is secure, the magnet cannot be moved. 4.1.e Insert the first screw into a screw hole, then use a screwdriver to partially secure the screw in the wall. Do not fully insert the screw until the second screw has secured the magnet position. 4.1.f Insert a second screw into the remaining hole, and then partially secure it in the wall. 4.1.g Observe the magnet position. When satisfied with the position, use a screwdriver to fully secure each screw in the wall. 4.1.h Press the front of the magnet against the base, until there is an audible snap. Magnet adhesive 4.2.a Select the desired position for the magnet. 4.2.b Peel one side of the adhesive tape, and then press the tape firmly against the magnet. Note: Once the adhesive is secure, the magnet cannot be moved. 4.2.c Peel the other side of the adhesive, and then press the magnet against the wall. 5. Add the sensor to the panel. See Sensor Management, ClareOne User Guide. 25AUG23 Snap One, LLC. 3 / 5 DOC ID 1897 Rev 03 6. Once added, test the sensor. Look at the ClareOne panel, and then open the door/window. Notice that the added sensor displays faulted. Note: Testing all sensors with the alarm monitoring station is strongly advised. Table 1: Sensor and magnet gap range Non-metallic surface Supports Metallic surface Open Close Direction Open Close 4. Press and hold the tab away from the circuit board, and 31 mm 29 mm 34 mm 31 mm 35 mm 31 mm X Y Z 30 mm 25 mm 36 mm 35 mm 45 mm 40 mm Battery replacement The ClareOne Door/Window Sensor requires a CR2032 battery. Once the battery is low, the panel displays a low battery icon next to the sensor in the devices list. The battery must be replaced within 7 days of the first low battery notification. If the battery is not replaced within 7 days, the sensor may not function properly. WARNING: If an incompatible replacement battery is used, or the battery is installed incorrectly explosion or damages may occur. AVERTISSEMENT: Si une batterie de remplacement incompatible est utilise ou si la batterie est installe de manire incorrecte, une explosion ou des dommages peuvent survenir. To replace the battery:
Note: Verify that the panel is not armed before changing the battery. 1. Locate the bottom of the sensor (the slotted short end). 2. Gently slide a fingernail/fingertip into the slot and pull the sensor cover out and away from the sensors base. 3. The sensor containing the battery and circuit board is no longer attached to the door/window. Locate the tab holding the circuit board in the sensor. then turn the sensor over. The circuit board comes free from the sensor shell. 5. Use a fingernail/fingertip to push the battery out of the casing, noting the polarity of the battery. 6. Slide a new CR2032 battery into the battery casing, making sure that the polarity is correct. 7. Press the circuit board back into the sensor casing, sliding it under the clips, until secure. There will be an audible snap. 8. Press the sensor back onto the base. 9. Test the sensor. Specifications Compatible panel ClareOne Transmitter frequency 433MHz TX Encrypted Yes Transmitted indications Tamper Low battery Battery type CR2032 (220mAh) Battery life Screw size Adhesive 5 years M3 16 mm 3M 4930 Sensor dimensions
(W H D) 1.69 2.52 .51 in.
(43 64.05 13 mm) Operating environment Temperature Relative humidity 32 to 122.6F (0 to 50C) 85% max Water-resistant No 25AUG23 Snap One, LLC. 4 / 5 DOC ID 1897 Rev 03 Regulatory information Manufacturer Snap One, LLC. North American standards ETL listed to: UL 634, ULC ORD634 FCC compliance FCC ID: 2AJAC-CLRC1DW This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-
located or operating in conjunction with any other antenna or transmitter. IC Compliance IC ID: 7848A-CLRC1DW ISED compliance statement:
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation. Science and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. L'metteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR d'innovation. Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage;
L'appareil doit accepter tout brouillage 2. radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Radiation Exposure statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites d'exposition aux radiations IC CNR-102 tablies pour un environnement non contrl. Cet metteur ne doit pas tre colocalis ou fonctionner en conjonction avec une autre antenne ou un autre metteur. Warranty information Snap One offers a two (2) year limited warranty on original Clare components, from the date of shipment from Snap One. To view complete limited warranty details, including limitations and exclusions, www.snapone.com/legal. Scan the code to view product warranty details. Contact information www.clarecontrols.com Integrator/Dealer Support: 866-424-4489 claresupport@clarecontrols.com Homeowners should contact their professional installer for assistance. 25AUG23 Snap One, LLC. 5 / 5 DOC ID 1897 Rev 03