MTP60 User Manual Wideband Wireless Professional Pocket Transmitter SN: ________________ Rev.01 (ref. FW 0.3) Date: 22 October 2021 MTP60 User Manual PRODUCT OVERVIEW OLED white display (128 x 64 pixels) IrDa interface 4 setup buttons LED3 of recording battery compartment latch LED4 of recharging MIC connector (LEMO 1pin) battery compartment Antenna connector (LEMO 3pin) SD card slot LED1 for audio and recording indication LED2 for RF and battery indication USB-C connector
(for power and control) 2 MTP60 User Manual LED INDICATIONS LED 1 - audio and recording indication Fixed green unit is modulating regularly Blinking red Flash when audio is clipping OFF (grey) if it doesnt modulate LED 2 - RF and battery indication Fixed red with RF OFF Fixed Green with RF ON Blinking red when battery is discharging LED 3 - recording OFF (grey) when recording is OFF Fixed red when recording is ON LED 4 - recharging status OFF (grey) when no recharging Blinking orange when is under recharging Fixed Green when recharge is completed SETUP CONTROL Use the 4 front buttons to navigate on the menu and enable quick setup:
to switch ON the transmitter to enter on a sub-menu to save the parameter to switch OFF the transmitter to exit from a sub-menu to switch ON the transmitter without audio modulation
(only tone squelch) to circle on the same level to enter on the GAIN settings (from STATUS menu) to circle on the same level to enter on the CHANNEL settings (from STATUS menu) SEL+GAIN: to enter on the menu SEL+EXIT: to mute audio EXIT+CH: to lock transmitter GAIN+CH: to start recording SEL/ON:
o o o EXIT/OFF:
o o o UP/GAIN:
o o DOWN/CH:
o o 3 MTP60 User Manual DISPLAY MENU Setup menu are accessed in sequence:
4 MTP60 User Manual PRESET menu MTP60 can recall configuration presets. o o o Factory recalls the Wisycom factory configuration. USER (U01, U02) recalls the configuration saved by menu PRESET recalls preset saved with the Wisycom Manager or pre-configured by Wisycom TUNING > Frequency menu In this menu current channel/group and frequencies can be setup. The name of the group is shown on the top right of the display. Sync group is a quick self-settable channel synchronized by receiver (with SYNC group, on the top right of the display is shown the name of the synchronized receiver). Use arrows to change value and <ENTER> to confirm. Using quick channel setup buttons (<CH>), it is possible to enter quickly in the tuning menu. TUNING > Level menu RF power can be setup to 20mW, 20mW Linear, 50mW or 100mW (depending on the Power profile, see TUNING>Pwr Profile menu). Set to ON to activate the transmission. LED2 becomes fixed green when the transmitter is tuned and RF power is ON. With this menu it is possible to set all the audio parameters: gain, modulation (Narrowband or Wideband), type of microphone, audio filters and the Tone. TUNING > Pwr on AUDIO menu SETTINGS menu Use this menu to o o o o o activate the Bluetooth interface activate the Irda interface set type of battery used configure LEDs behaviour configure brightness and time of display INFO menu Use this menu to check information about the transmitter (serial number, frequency range, firmware and hardware version) and its status (voltage, temperature and alarms). 5 MTP60 User Manual BATTERIES MTP60 works with 2 x AA battery, Lithium, NiMh or KLIC8000 lithium (5.6 Wh) (select correct type on setup controls). Battery status can be checked on internal OLED display or looking the LED2 status on front . BATTERY SUBSTITUTION Open transmitter cover and insert batteries following polarity indicated. Attention: always replace both the batteries AUDIO CONNECTOR 3 PIN LEMO CONNECTOR
(use FVB.00.003.NLN on Mic) Pin out 1=GND 3=AF 1=GND 3=AF+5.5V 1=GND 2=5.5V 3=AF MIC Mode:
2 wires:
2 wires + bias:
3 wires:
2 wires &
phantom:
2 wires + bias &
phantom:
1=GND 2=3.1V (power for PHA48 and PHA60) 3=AF 1=GND 2=3. 1V (power for PHA48 and PHA60) 3=AF+5,5V 6 ACCESSORIES AND PARTS AWF30-B1-507 For MTP60-US Band 470 -547 MHz Antenna label 507 AWF30-B1-590 For MTP60-US Band 547 - 663 MHz Antenna label 590 AWF30-B8-950 For MTP60-US Band 940 -960 MHz Antenna label 950 MTP60 User Manual Antenna label CAL48 Cable to connect an MTP30 (with option /PHA) or MTP40/40S to a PHA48 to use microphone with XL3/48V connection CAL120 AF cable (120cm), LEMO 3pole / XLR-3F connectors PHA48 Plug-on for XLR3 Mic with 48V Phantom power. To be used with CAL48 (connected to an MTP30/40/40S) NEW REV2 with 4mA Phantom current!
7 MTP60 User Manual TECHNICAL SPECIFICATIONS Frequency ranges from 470 to 1075 Mhz, depends on the country (see Configurations) Switchable channels 2400 managed in 40 groups ofr 60 frequencies completely user customizable Switching-window Up to 362 MHz, depending on band (see Configurations) Frequencies Quartz PLL frequency synthesizer circuit (25 kHz step) Frequency error 2.5 ppm, in the rated temperature range RF Power switchable typ. 20 mW/ L20 mW / 50 mW /100 mW note: in some countries high power can be disabled, for local norm!
Antenna connector LEMO-F 1 pin Modulation wideband/narrowband FM, with digital audio conditioning (FPGA) Nominal deviation 40 kHz Wideband / 25 kHz Narrowband Peak deviation 56 kHz Wideband / 35 kHz Narrowband Spurious emissions
< 2 nW Telemetry feature TX transmits also a digitally modulated sub-carrier, suitable for:
tone-squelch operating remote battery monitoring optional PTT (push to talk) operation Noise Reduction system ENS - Wisycom Extended-Sound Optimized AF bandwidth in NarrowBand Audio frequency response (dBa):
mode (NB) 45 Hz - 17 KHz (3dB) AF bandwidth in WideBand Audio frequency response (dBa):
mode (WB) Distortion 45 Hz - 20 KHz (3dB)
< 0.3 % (0.15 % typ.) SND/D ratio (Analogue) typ. 115 dB (A)rms with 40 kHz deviation; typ. 121 dB (A)rms with 56 kHz deviation Wideband typ. 115 dB (A)rms with 25 kHz deviation; typ. 121 dB (A)rms with 35 kHz deviation Audio input connector LEMO 3pin Narrowband Audio input level from -36 dBu (12mV RMS) to 26 dBu (15.5 V RMS) adjustable in 1 dB steps Max input level
+26 dBu (15.5 V) at clipping, +20 dBu (7.75 V) at nominal level Managing interface Bluetooth 5 long range, USB-C, IrDA LED 2 RGB LEDs indication with (red, green and blue) LED 2:
Fixed Red with RF OFF Fixed Green with RF ON Blinking RED when battery is dicharging LED 1 Green unit is modulating regularly Red Flash when clipping OFF (grey) if it doesnt modulate Fixed RED when recordin in ON Battery lifetime indication 10 steps PTT function Pin 3 of the AF connector can be setup to an external push button Display High contrast OLED white display (128 x 64 pixels) Power supply 2 x AA battery, KLIC8000 lithium (5.6 Wh) or NiMh Power consumption 250mA@ 2.6V average (display off, 100mW power) Temperature range
-10 - +55 C Dimensions 75,7mm x 61,4mm x 19mm (HxWxD) without clip Weight Approx. 91 g. without batteries (133 g. with batt.) 8 MTP60 User Manual Compliance Model MTP60-EU MTP60-EUX In Compliance with EN 301 489-1/-9 EN 600065 EN 300 422-1/-2 EN 301 489-1/-9 EN 600065 EN 300 422-1/-2 EN 300 454-1/-2 MTP60-US PART 74 & PART 15 FCC-ID: POUMTP60 MTP60-CA RSS-123, RSS-102 IC: 11967A-MTP60 Max Power Country 50mW Europe 100mW*1 Europe 100mW USA 100mW Canada
*1 MTP60-EUX is not an SRD device, thus it requires specific authorization by your local frequency authority!
Before putting the device into operation, please observe the respective country-specific regulations!
9 MTP60 User Manual MANUFACTURER DECLARATIONS In compliance with the following requirements RoHS Directive (2002/95/EC) WEEE Directive (2002/96/EC) Please dispose of the diversity transmitter at the end of its operational lifetime by taking it to your local collection point or recycling center for such equipment Battery Directive (2006/66/EC) The supplier batteries or rechargeable batteries can be recycled. Please dispose of them as special waste or return them to your specialist dealer. In order to protect the environment, only dispose of exhausted batteries. ITALY ONLY Obblighi di informazione agli utilizzatori ai sensi dellart. 13 del Decreto Legislativo 25 luglio 2005, n. 151 Attuazione delle Direttive 2002/95/CE, 2002/96/CE e 2003/108/CE, relative alla riduzione delluso di sostanze pericolose nelle apparecchiature elettriche ed elettroniche, nonch allo smaltimento dei rifiuti Smaltimento di apparecchiature elettriche ed elettroniche di tipo professionale Il simbolo del cassonetto barrato riportato sullapparecchiatura o sulla sua confezione indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti. La raccolta differenziata della presente apparecchiatura giunta a fine vita organizzata e gestita dal produttore. Lutente che vorr disfarsi della presente apparecchiatura dovr quindi contattare il produttore e seguire il sistema che questo ha adottato per consentire la raccolta separata dellapparecchiatura giunta a fine vita. Ladeguata raccolta differenziata per lavvio successivo dellapparecchiatura dismessa al riciclaggio, al trattamento e allo smaltimento ambientale compatibile contribuisce ad evitare possibili effetti negativi sullambiente e sulla salute e favorisce il reimpiego e/o riciclo dei materiali di cui composta lapparecchiatura. Lo smaltimento abusivo del prodotto da parte del detentore comporta lapplicazione delle sanzioni am-
ministrative previste dalla normativa vigente. Smaltimento batterie usate Questo prodotto pu contenere batterie. Questo simbolo apposto sulle batterie significa che non possono essere smaltite insieme a normali rifiuti domestici, bens devono essere depositate negli appositi punti di raccolta delle batterie. Iscrizione al Registro A.E.E. n. IT09100000006319 10 MTP60 User Manual Statements regarding FCC and Industry Canada THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. WARNING: Wisycom srl. is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the users authority to operate the equipment. The FCC and IC identifier is visible in the display when the device is switched on and it is also available by accessing the Options> Info> Regulatory submenus. EN This device complies with Industry Canada license-exempt RSS-123 and RSS-210 standard. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter IC: 11967A-MTP60 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. FR Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence RSS-123 et RSS-210. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Le prsent metteur radio IC: 11967A-MTP60 a t approuv par Industrie Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal et l'impdance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur. Antenna types (50 Ohm impedance, max gain 2.1dBi) AWF30-B1-507: band 470 - 547 MHz AWF30-B1-590: band 547 - 663 MHz AWF30-B8-950: band 940 - 960 MHz This equipment complies has been evaluated for and shown compliant with the FCC and ISED RF Exposure limits. The unit of measurement for RF exposure is Specific Absorption Rate (SAR). The FCC SAR limits for is 1.6W/Kg per 1g of tissue 11 MTP60 User Manual The maximum SAR levels tested has been shown to be 1.2 W/kg at head with 0mm of separation distance from the body. This device operates on a no-interference, no-protection basis. Should the user seek to obtain protection from other radio services operating in the same TV bands, a radio license is required. For further details, consult Innovation, Science and Economic development Canada's Client Procedures Circular CPC-2-1-28, Voluntary Licensing of License-Exempt Wireless Microphones in TV Bands. SAFETY INSTRUCTION Read this safety instruction and the manual first Follow all instructions and information. Do not lose this manual. Do not use this apparatus under the rain or near the water. Do not install the apparatus near heaters or in hot environments, do not use outside the operating temperature range. Do not open the apparatus, only qualified service technician are enabled to operate on it. The apparatus needs servicing when it is not properly working or is damaged by liquids, moisture or other objects are fallen in the apparatus. Use only accessories or replacement parts authorized or specified by the manufacturer. Clean the apparatus only with dry cloths, do not use liquids. Report the serial number and the purchasing date in front of the manual. It is needed to have proper replacement parts or accessories from the manufacturer. When replacement parts are needed, use only replacement parts authorized from the manufacturer. Substitution with not authorized parts could result in electric shock, hazards or fire. Keep attention on all the labels with warnings or hazards on the apparatus. 12 DECLARATION OF CONFORMITY MTP60 User Manual 13 MTP60 User Manual 14 Via Tiepolo, 7/E - 35019 Tombolo (PD) Italy Tel. +39 -0424 -382605 Fax +39 - 0424 - 382733 www.wisycom.com e-mail: sales@wisycom.com