SiXC2W Convert to Wireless / Convert to Wireless Quick Installation Guide The Honeywell SiXC2W is an eight zone hardwire to wireless converter used with controllers that support Honeywells SiX series devices. It is useful in retrofit 12-
volt security system applications where existing contact wiring was used. It uses those existing wired contacts and converts them to wireless. FEATURES Provides 12-volts for devices such as motion detectors, glass breaks, etc. NOTE: Only two devices may be powered using the auxiliary output on the SiXC2W. Provides 24-hour battery backup (4-hour if external devices are connected). NOTE: It immediately sends a power loss signal to the controller in the event the power is lost. When no battery is connected, low battery message will send to control panel. When battery is connected, and if battery voltage drops below 3.6VDC, a low battery message sends to the control panel. When only the battery is connected, and if the battery voltage 3.4 V, system will shut down. Support one button calibration Automatic zone configuration Easy setup in three steps Cover tamper protection IMPORTANT!
Not to be used for fire, heat, or carbon monoxide detectors. CALIBRATING The calibration process enables the SiXC2W to learn what zones are to be active and what value EOL resistors are used. IMPORTANT!
Unused zones that are open ARE NOT recognized and reported. 1. Ensure all zones are connected and not faulted. 2. On the SiXC2W, press and release the top middle 3. button. Indicator LED #2 will flash Red for 1/2 second; then LED #3 turns steady Green. 4. Calibration is in process 5. DONE. The SiXC2W is calibrated and ready to enroll in the control panel. NOTES:
If the SiXC2W loses both AC and battery backup power, the zone calibration data is retained. If there is an existing resistor, it MUST have a value between 1K and 10K.The unit comes with eight (8) 2.2K resistors for zones that dont have one. IMPORTANT!
Once the SiXC2W is calibrate, any change in the zone resistance the module must be re-calibrated. Guide d'installation rapide The Honeywell SiXC2W is an eight zone hardwire to wireless converter used with controllers that support Honeywells SiX series devices. It is useful in retrofit 12-volt security system applications where existing contact wiring was used. It uses those existing wired contacts and converts them to wireless CARACTRISTIQUES Provides 12-volts for devices such as motion detectors, glass breaks, etc. NOTE: Only two devices may be powered using the auxiliary output on the SiXC2W. Provides 24-hour battery backup. (4-hour if external devices are connected). NOTE:
It immediately sends a power loss signal to the controller in the event the power is lost. When no battery is connected, low battery message will send to control panel. When battery is connected, and if battery voltage drops below 3.6VDC, a low battery message sends to the control panel. When only the battery is connected, and if the battery voltage 3.4 V, system will shut down. Support one button calibration Automatic zone configuration Easy setup in three steps Cover tamper protection IMPORTANT!
Not to be used for fire, heat, or carbon monoxide detectors. CALIBRATING The calibration process enables the SiXC2W to learn what zones are to be active and what value EOL resistors are used. IMPORTANT!
Unused zones that are open ARE NOT recognized and reported 1. Ensure all zones are connected and not faulted. 2. On the SiXC2W, press and release the top middle 3. button. Indicator LED #2 will flash Red for 1/2 second;
then LED #3 turns steady Green. 4. Calibration is in process 5. DONE. The SiXC2W is calibrated and ready to enroll in the control panel. NOTES:
If the SiXC2W loses both AC and battery backup power, the zone calibration data is retained. If there is an existing resistor, it MUST have a value between 1K and 10K.The unit comes with eight (8) 2.2K resistors for zones that dont have one. IMPORTANT!
Once the SiXC2W is calibrate, any change in the zone resistance the module must be re-calibrated. ENROLLING / ENROLLING Lyric Control Lyric Controller Enrollment Process, See Controllers installation instructions for its proper programming process. For Lyric Gateway Use AlarmNet 360 to enroll and program this sensor. Lyric Control Lyric Controller Enrollment Process, See Controllers installation instructions for its proper programming process. For Lyric Gateway Use AlarmNet 360 to enroll and program this sensor. For Other Controls For other controls that support SiX series devices, see the controllers installation app for details NOTE: Once enrolled in a system, the SiXC2W cannot be used with another controller until it is removed from the current controller. See the Controllers instructions for details. For Other Controls For other controls that support SiX series devices, see the controllers installation app for details NOTE: Once enrolled in a system, the SiXC2W cannot be used with another controller until it is removed from the current controller. See the Controllers instructions for details. MOUNTING / MONTAGE Signal strength:
Rang of 1-4 bars (green), should be a minimum 1 green bar for the zone being programmed. Four Red Bards indicate poor signal strength; the device should be relocated. See the controllers instruction for bar indication signal strength values. Icon Description 4 Green Bars Signal Strength 3 Green Bars 2 Green Bars 1 Green Bar Good 4 Red Bars Relocate TAMPER/LOW BATTERY REPORTING The SiXC2W reports this condition to the control. If a low battery or tamper condition exists all zones used on the module shows a trouble on the control. TAMPER/LOW BATTERY REPORTING The SiXC2W reports this condition to the control. If a low battery or tamper condition exists all zones used on the module shows a trouble on the control. IMPORTANT:
The first battery test occurs 1 hour after power up. To quickly verify a good backup battery, unplug and then plug back in the power supply; the system will perform a battery test within 1 minute. IMPORTANT:
The first battery test occurs 1 hour after power up. To quickly verify a good backup battery, unplug and then plug back in the power supply; the system will perform a battery test within 1 minute. LED INDICATIONS LED # / LED #
1 (Green / Green) 2 (Red / Red) 3 (Green / Green) 4 (Green and Red /
Green and Red) Functions / Functions Blinks once upon RF signal transmission (HW zone trigger/tamper and/or a fault message), slow blink for a cover tamper, quick blinks for enrollment or deletion / Blinks once upon RF signal transmission (HW zone trigger/tamper and/or a fault message), slow blink for a cover tamper, quick blinks for enrollment or deletion Blinks 1s / 1s off when module needs calibrating / Blinks 1s /
1s off when module needs calibrating Steady on when the module has been calibrated. / Steady on when the module has been calibrated. Green: 5VDC Power from the plug-in transformer is present Red (blinking 1sec on / 1 sec off): Running on battery, DC power not present. / Green: 5VDC Power from the plug-in transformer is present Red (blinking 1sec on / 1 sec off):
Running on battery, DC power not present. Approval Listings / Approbations Homologations:
FCC / IC - ETL Listed to UL268 & 521 cETL Listed to ULC S530 & S531 Other Standards / Autres normes: RoHS FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and Industry Canadas license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la partie 15 des rgles de la FCC et exempt de licence RSS dIndustrie Canada. Son fonctionnement est soumis aux conditions suivantes:
(1) Cet appareil ne doit pas causer dinterfrences nuisibles. (2) Cet appareil doit accepter toute interfrence reue y compris les interfrences causant une rception indsirable. SPECIFICATIONS / SPCIFICATIONS:
Voltage Transformer Part # ................................... 300-10259 Input Voltage ............................................... 100 ~ 240VAC, 50 ~60 Hz Operating Voltage ..................................... 5VDC Maximum Transformer Distance ...... 9.8ft. (3m) Voltage Output ........................................... 12VDC @ 100mA (Up to three sets of 2024 Battery/ Pile ................................................. P/N 300-10342 Environmental Operating Temp ......................................... 14 F (-10C) to 140F (60C) Relative Humidity ...................................... 95%, Non-condensing / 95% max. sans NOTE: Charging the lithium battery stops when temperature is below 32F
(0C) gauge wiring) condensation Physical Dimensions .................................................. Length 7.0 in (178 mm) x Mounting Hardware ................................. Double stick tape and screws Zone Resistance ......................................... 1K to 10K Ohm EOL Resistors Zone Wiring .................................................. 1,000ft (Each Zone) Width 4.5 in (114 mm) x Depth 1.5 in (38mm) Radio Frequency Transmission Range ................................ 300ft (91.5m) BATTERY REMOVAL AND INSTALLATION Caution: The batteries used in this device may present a fire or chemical burn hazard if mistreated. Do not recharge, disassemble, heat above 212F
(100C) or dispose of in fire. Use Panasonic CR123A or DURACELL DL123, DL 123A Lithium batteries. Use of other batteries may present a risk of fire or explosion. Keep used batteries away from children. Dispose of used batteries properly. Remove old batteries. Wait 10 seconds and then replace with four new batteries. To avoid a low battery indication when installing new batteries, both batteries must be installed within 15 seconds of installing the first one. Any low battery condition that may have occurred should clear when the back plate is installed. Mise en garde : Les piles utilises dans ce dispositif peuvent prsenter des risques d'incendie ou de brlure chimique si elles sont mal traites. Ne rechargez pas, ne dsassemblez pas, ne faites pas chauffer et ne jetez pas au feu les piles plus de 100 C (212 F). Utilisez des piles au lithium Panasonic CR123A ou DURACELL DL123, DL 123A. L'utilisation d'autres types de piles peut prsenter des risques de feu ou d'explosion. Gardez les vieilles piles hors de la porte des enfants. Dbarrassez-vous des batteries utilises de faon approprie. Retirez les vieilles piles. Attendez 10 secondes et remplacer-les par quatre nouvelles piles. Pour viter une indication de piles faibles lorsque vous installez de nouvelles piles, les dos (2) piles doivent tre installes en de de 15 secondes aprs l'installation de la premire. Toute condition de pilles faibles qui aurait pu se produire devrait tre rtablie une fois la plaque arrire installe. REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. POUR LES LIMITES DU SYSTME DALARME AU COMPLET, REPORTEZ-
VOUS AU GUIDE DINSTALLATION DU PANNEAU DE COMMANDE Voir les instructions d'installation compltes 800-24139-
https://mywebtech.honeywell.com/. See Honeywell Installation Guide P/N 800-24139 https://mywebtech.honeywell.com/. Support / Pour de lassistance en ligne, visitez :
https://mywebtech.honeywell.com/
U.S. warranty / U.S. garantie: www.honeywell.com/security/hsc/resources/wa For patent info, see: / Pour des informations sur les brevets, voir :
www.honeywell.com/patents MyWebTech Warranty / Garantie Patents / brevets 2018 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved.