submitted | available | document details (if available) | source link |
---|---|---|---|
Microsoft Word - K0903V1-E_6160RF-ii.doc e311757 Acrobat Distiller 4.05 for Windows |
various | Users Manual | Users Manual | 130.98 KiB |
K0903V1 2/06 Rev. E ADEMCO 6160RF ADEMCO 6160RF ADEMCO 6160RF ADEMCO 6160RF Keypad/Transceiver Keypad/Transceiver Keypad/Transceiver Keypad/Transceiver Installation and Setup Guide Installation and Setup Guide Installation and Setup Guide Installation and Setup Guide GENERAL INFORMATION The ADEMCO 6160RF keypad/transceiver is a combination unit that combines the functions of the following devices:
6160 Alphanumeric Addressable Keypad 5881H RF Receiver 5800TM Transmitter Module The 6160RF Keypad/Transceiver may be used on any control panel that supports 5800 Series wireless devices
(e.g., VISTA-10P, VISTA-15P, and VISTA-20P). FEATURES Supports wireless key transmitters (e.g.; 5804) and bi-directional transmitters (e.g.; 5804BD, 5828/5828V). Supports wireless keys with high-security (encryption) capability (e.g.; 5804E, 5834-4). Provides a nominal range of 200 feet for RF transmitters (some transmitters have a shorter range). Supports RF jam detection when the receiver is enabled. Capable of sending status signals (Armed, Ready, etc.) to bi-directional units such as 5804BD, 5804BDV and 5814, 5819, 5819BRS, 5819WHS, and 5828/5828V. 2. Pass the wiring from the control panel through 5828/5828V. UUUULLLL The following 5800 series transmitters are not intended for use in UL installations: 5802, 5804, 5804BD, 5804BDV, 5804E, INSTALLING THE 6160RF Locate the 6160RF in an area and at a height where it is convenient for user operation. The 6160RF must be at least 10 ft from the control panel to ensure proper operation of the RF receiver. Mounting and Wiring The 6160RF has terminal blocks for connection to power and data wires. Removing the keypads case back provides access to the terminal blocks. The 6160RF can be surface mounted directly to walls, or to a single- or double-gang electrical box. Follow these steps to mount and wire the keypad:
1. Push the two case release snaps at the bottom of the opening in the case back. (see the control panels instructions for proper run lengths.) a. If surface wiring is being used, wiring may be routed through the top or the bottom left-side breakout in the case back. The breakouts must be punched out using a screwdriver before mounting the case back. wire tie point on the inside of the case back with a tie wrap (not supplied). 3. Mount the case back to a wall or to an electrical b. If desired, wires may be strain-relieved to the the keypad with the blade of a medium screwdriver (this will push in the release snap), then pull that side of the case back away. Insert the screwdriver in the side of the keypad
(between the front and back case) and gently twist to release the side locking tab. Repeat for the other side. Refer to Figure 1 for location of the case back release snaps and locking tabs. ARMED READY NOTE:
TO REMOVE REAR COVER PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT COVER UP. box using the 25mm-long self-tapping screws supplied (mollies for drywall are not supplied). 4. Connect the power and data wires from the control panel to the terminals on the 6160RF as indicated in Figure 2 and Table 1. Y +
++++
G MOUNTING RELEASE SNAPS LOCKING TAB Figure 1. Removing the Case Back 1 V
-
3 0 0
-
F R 0 6 1 6 WIRING TERMINALS
(TO CONTROL PANEL) Figure 2 - 6160RF Wiring Details 1 V
-
2 0 0
-
F R 0 6 1 6 Table 1 - Wiring Table Keypad GM (Data Out)
-
+
LY (Data In) Control Panel Data In
-Aux Pwr (GND)
+Aux Pwr Data Out Wire Color Green Black Red Yellow APPLICATION GUIDELINES FOR THE 6160RF Use the following guidelines when planning an installation:
5. Reattach the keypad to the mounted case back. Attach the top of the keypad first, and then press the bottom section down until it snaps into place securely. 6. Peel off protective film on the LED panel and install the keypad labels as required. If This is the only transceiver on the system, And You want to use both the receiver and transmitter function on a single-partition system, There is another receiver or transceiver on the system, You want to use only the transmitter function on a second partition, You want to use only the transmitter function on a single-
partition system, Then Set the keypad to a device address assigned to the desired partition.*
Enable the receiver. Program a system House ID in the control panel (this will enable the transmitter function).**
Set the wireless devices that will communicate with this 6160RF to the same system House ID. Set the keypad to a device address assigned to the desired partition.*
Disable the receiver. Program a DIFFERENT House ID in the 6160RF than is programmed in the control panel.*/ **
Set the wireless devices that will communicate with this 6160RF to the same House ID as the 6160RF. Set the keypad to a device address assigned to the Partition 1. Disable the receiver. Program a House ID in the 6160RF that matches the system House ID programmed in the control panel.*
Set the wireless devices that will communicate with this 6160RF to the same House ID. Notes:
* On VISTA-40 panels and above, wireless keypads (e.g., 5804BD) can only be used on a single partition. This partition is programmed in field 1*48, and must match the partition assigned to the 6160RF. Wireless keys can be used on more than one partition, using a House ID programmed in the 6160RF and the devices. In this case, the wireless keys must be assigned to the same partition as the 6160RF.
** On VISTA-20P panels, the 6160RF will use the House ID programmed in the panel for the partition to which it is assigned. Wireless keypads can only be used on Partition 1. PROGRAMMING THE 6160RF Refer to the following procedure to program the 6160RF:
STEP DESCRIPTION Enter the program mode by pressing the [1] and [3] keys simultaneously for a few seconds within 60 seconds after applying power.
(Keypad Address) Enter the two-digit keypad address. Press the [] key to continue. Notes: (1) Refer to the control panels installation instructions for the acceptable keypad addresses.
(2) On the VISTA-40 and above the 6160RFs partition assignment must match the RF keypad partition assignment programmed in field
(1*48). 1. 2. 3.
(Receiver Enable) Enter [1] to enable, or [0] to disable Receiver. Enable the receiver if RF transmitters or wireless keypads are programmed into the control and no other receivers are enabled. Press the [] key to continue. RECEIVER RECEIVER RECEIVER RECEIVER ON [0= OFF]
OFF]
ON [0 ON [0 ON [0 OFF]
OFF]
1= ON 0 = OFF
- 2 -
DISPLAY CHOICES CON ADDRESS = XX XX XX XX CON ADDRESS CON ADDRESS CON ADDRESS 00-31 STEP 4. 5. 6. 7. DESCRIPTION
(Receiver Address) If receiver is enabled, enter the two-digit receiver address. (00-30). Note: Refer to the control panels installation instructions for the acceptable receiver addresses. Press the [] key to continue.
(House ID) This prompt will only appear if the receiver is disabled. If the receiver is enabled the 6160RF will use the House ID programmed in the panel. Refer to Application Guidelines section when selecting a House ID. To program a House ID: Enter 01-31. To disable the transmitter: Enter 00 Note: Each device that will receive status from the 6160RF must be set to the same House ID as the 6160RF (refer to Application Guidelines section). Press the [] key to continue.
(Enable High Security Mode) Enter [1] to select High Security Mode. Note: If the High Security mode is enabled, the 6160RF will only recognize encrypted devices. If this mode is disabled, the 6160RF will process commands both encrypted and non-encrypted devices. Press the [] key to continue.
(Disable High Security Devices) Press the [] key to skip this prompt and exit Program Mode. Notes: (1) The [] key must be pressed several times in order to save the DISPLAY REC ADDRESS= XXXXXXXX REC ADDRESS REC ADDRESS REC ADDRESS CHOICES 00-30 HOUSE ID = XX XX XX XX HOUSE ID HOUSE ID HOUSE ID 00-31 HIGH SECURITY HIGH SECURITY HIGH SECURITY HIGH SECURITY OFF [1]]]] = ONONONON OFF [1 OFF [1 OFF [1 1= Enable 0 = Disable DISABLE HS DEV?
DISABLE HS DEV?
DISABLE HS DEV?
DISABLE HS DEV?
NO [1]]]] = YESYESYESYES NO [1 NO [1 NO [1 1= YES 0 = NO
(2) If you need to disable encrypted devices, refer to the Disabling High programmed data. Security Devices section. ACTIVATING HIGH SECURITY DEVICES This following procedure should be followed if using High-Security (encrypted) devices. STEP 1. 2. 3. DESCRIPTION Follow the normal procedure for programming the device into the control panel (refer to the Installation Instructions for the device that you are programming). Exit out of Programming Mode. Put the control panel in Go/ No Go Test mode. (See the Installation Guide for the panel being installed.) Follow the instructions supplied with each wireless device to enroll the device in High-security mode. After each device is enrolled the 6160RF will momentarily display SECURITY DEVICE along with the device number and its serial number. Note: The 6160RF will support a maximum of 8 devices. If you attempt to enroll additional devices the keypad will display EXCEEDED NUMBER ALLOWED DEVICES. DISABLING HIGH SECURITY DEVICES This mode gives you the ability to disable high security on all wireless keys that have been enrolled in the 6160RF. This is particularly useful if a user loses a wireless key.
STEP 1. 2. 3. Once high-security (encrypted) devices have been disabled, they will only operate if the 6160RF is set to listen to both encrypted and non-encrypted devices (programming step 6, above). To completely disable the devices, they must be deleted from the control panel. DESCRIPTION After the keypad has been powered for at least 60 seconds hold down the [1] and [3] keys at the same time for 3 seconds. The current keypad address will be displayed. (You cannot change the keypads address at this point.) Press the [] key to continue.
(Delete High Security Devices) Press the [1] key to remove all high-
security (encrypted) devices. Press the [] key to continue. If YES was selected in Step 2 the unit will display a confirm request to delete the stored high security device. Press the [1] key to accept, followed by the [] key to exit the programming mode. DISPLAY CON ADDRESS=XXXXXXXX CON ADDRESS CON ADDRESS CON ADDRESS CHOICES 00-31 DISABLE HS DEV?
DISABLE HS DEV?
DISABLE HS DEV?
DISABLE HS DEV?
NO [1]]]]=YESYESYESYES NO [1 NO [1 NO [1 ARE YOU SURE?
ARE YOU SURE?
ARE YOU SURE?
ARE YOU SURE?
NO [1]=YESYESYESYES NO [1]
NO [1]
NO [1]
1= YES 0 = NO 1= YES 0 = NO
- 3 -
TROUBLESHOOTING The error messages listed in the following table cause the 6160RF to produce a single ding tone. The table describes the error messages and the corrective actions. Display Low Bat (with zone no.) Open Ckt Check 100 Check 1xx*
Probable Cause Low battery in the wireless device. No data is being received from the control panel. 1. The control panel does not see the 6160RF Receiver, or the Receiver is not functioning. 2. Another device on the keypad terminals is not communicating to the control panel. Corrective Action 1. Replace the battery if the wireless transmitter has a replaceable battery. 2. Replace the transmitter if the wireless transmitter does not have a replaceable battery. Verify that the keypad LY (yellow) wire is connected properly. 1a. Verify that the keypad LY (yellow) and GM (green) wires are connected properly. 1b. Verify that the controls receiver address is correct. 2. Verify the wiring connections between the control and all other devices.
*xx= the device address of the receiver. SPECIFICATIONS Physical:
Wiring:
Range:
Frequency: 345 MHz 5-3/8 H x 7-3/8 W x 1-1/4 D
(137mm x 187mm x 32mm) Refer to Table 1 200 ft (60.9 m) nominal Current:
Display:
Sounder:
50mA Standby Backlighting on and Sounder on 2 x 16 alphanumeric supertwist LCD, backlit Tone Generator Integrated Circuit. (fire alarm is loud pulsing tone;
burglary/audible panic alarm is continuous tone) 150mA FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL PANEL BEING INSTALLED IN CONJUCTION WITH THIS DEVICE. The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FEDERAL COMMUNICATIONS COMMISSION STATEMENTS CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
If using an indoor antenna, have a quality outdoor antenna installed.
Reorient the receiving antenna until interference is reduced or eliminated.
Move the radio or television receiver away from the receiver/control.
Move the antenna leads away from any wire runs to the receiver/control.
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. FCC/IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la partie 15 des rgles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute interference reue y compris les interferences causant une reception indsirable. WARRANTY INFORMATION For the latest warranty information, please go to:
http://www.security.honeywell.com/hsc/resources/wa K0903V1?
K0903V1 2/06 Rev. E 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright 2011 Honeywell International Inc. www.honeywell.com/security
This product uses the FCC Data API but is not endorsed or certified by the FCC