Important Information The LYNX Plus Series control is equipped with a redesigned circuit board featuring relocated battery and communication port connections and redesigned antennas. Please refer to the figure below and to the Summary of Connections when making wiring connections and routing cables. WIRE ROUTING TUNNELS TIE-WRAP POINT MOUNTING HOOKS TERMINAL STRIP TELEPHONE CONNECTION LOCAL SOUNDER DISABLE SWITCH LYNX Plus Wiring and Connection Overview TIE WRAP TIE WRAP MOUNT NOTE ENSURE ALL WIRING IS ROUTED THROUGH WIRE STRAIN RELIEF CLIP WIRE STRAIN RELIEF CLIP BATTERY CABLE POWERLINE CARRIER DEVICE CONNECTOR GSMVLP4G AUDIO CABLE CONNECTOR 1000-300-006-V5 EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL. POWER SHUTDOWN NOTE: AT 6.0VDC THE SYSTEM WILL NOT OPERATE. UL INSTALLATIONS THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAGE WARNING TO PREVENT RISK OF SHOCK, DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT EARTH GROUND INCOMING TELEPHONE LINE PREMISES TELEPHONE TIP RING TIP RING HARD WIRED ZONE 2k OHMS EOLR 6-14VDC 120mA max. BELL TO 24HR 110VAC UNSWITCHED OUTLET NOTE USE ONLY THE K10145WH/K10145X10 OR K10145CN CLASS 2 TRANSFORMERS PROVIDED K10145WH/K10145X10 OR K10145CN PLUG-IN TRANSFORMER 9VAC, 25VA 8 POS JACK T 2 R 3 1 T HAND SET R HWZ SOUND OUT 4 5 6 7 8 9 AC 10 AC 11 INCOMING PHONE LINE EARTH GROUND PHONE ZONE SOUNDERS AC ON 85dB SIREN DISABLE SWITCH ALL OUTPUT CIRCUITS ARE POWER LIMITED. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2
(NATIONAL FIRE PROTECTION ASSOC., BATTERY MARCH PARK, QUINCY, MA 02169). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. LYNX PLUS SERIES ALSO COMPLIES WITH THE FOLLOWING:
CANADIAN STANDARDS ASSOCIATION (CSA) C22.1, CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS. THE LYNX PLUS SERIES CONTROLS ARE COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS:
P/N LYNXRCHKIT-SC P/N LYNXRCHKIT-HC P/N LYNXRCHKIT-SHA REPLACE EVERY FOUR YEARS WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM GSMVLP4G COMMUNICATIONS PORT STANDARD/HIGH-CAPACITY BATTERY CONNECTOR SUPER HIGH-CAPACITY BATTERY CONNECTOR POWERLINE CARRIER DEVICE CONNECTOR GSMVLP4G AUDIO CABLE CONNECTOR FCC ID: CFS8DLLYNXPLUS2
(LYNX PLUS SERIES) COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No. 5GBUSA-25623-AL-E RINGER EQUIVALENCE: 0.0043B WARNING THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CIRCUIT
(ZONE) 02 - 25 ZT16 CONTROL UNIT DELAY-SEC 30 seconds SMOKE DETECTOR MODEL DELAY-SEC 10 seconds 5806 LYNX PLUS SERIES SUMMARY OF CONNECTIONS 1000-300-SOC-V5 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright 2012 Honeywell International Inc. 800-13012M 800-13012 9/12 Rev. A www.honeywell.com/security