1 2 5800PIRRES-AP Wireless Motion Sensor - Installation Instructions 1 LOCATION / EMPLACEMENT No / Non / No Satisfactory 2 OPEN /
OUVERTURE 7.5 - 8 ft
(2.3 - 2.4 m) 4 MOUNT / INSTALLATION TOP 1
- Use only left OR right side corner mounting holes. Recommended Screws: #6 (3.5 mm) 2 B ACCESSORIES / ACCESSOIRES SMB-10 1
(P/N 0-000-110-01) SMB-10C
(P/N 0-000-111-01) SMB-10T 1
(P/N 0-000-155-01) IS2500-HSLK 1 35 x 40 (11 m x 12 m) IS2500-PALK 2 35 x 40 (11 m x 12 m) 1 Not verified by ETL. Swivel Mount Bracket Swivel Mount Ceiling Bracket Swivel Mount Bracket w/Tamper High Security Lens Kit Pet Alley Lens Kit Mounting Height:
1 7 9 ft (2.1 m 2.7 m). 2 4 ft (1.2 m). 3 CONNECT THE BATTERY, ENROLL THE SENSOR, CONDUCT GO / NO GO TEST, AND PERFORM WALK TEST / METTRE LES PILES EN PLACE , See page 2 for ENROLL THE SENSOR, CONDUCT GO / NO GO more information /
TEST, AND PERFORM WALK TEST See page 2 for more information Panasonic CR123A /
Duracell DL123 & DL123A /
Honeywell 466 Observe correct polarity /
Observe correct polarity A DETECTION PATTERNS / COUVERTURE DE DETECTION 35' / 11m Wide Angle Animal Immune Lens
(P/N 5-532-719-00) Top View / Vue de Dessus 13'
4m 20'
6m 7'
2m 35'
11m 27'
8m 0 20'
6m 1 2 3 4 5 6 7 8 18 19 20 12 13 14 15 16 17 13'
4m 7'
2m 0 7'
2m 13'
4m 20'
6m Side View / Vue de Cote 7'
2m 13'
4m 0 7'6"
(2.3m) 0 9 10 11 20'
6m 27'
8m 35'
11m PRELIMINARY DRAFT 8/24/09
- 1 -
5800PIRRES-AP Wireless Motion Sensor - Installation Instructions ENROLL THE SENSOR Enroll the sensor in the control panel prior to its usage in the system. Refer to the control panel instructions for programming details. Program the sensor as an RF type (supervised RF) device. To enroll: connect the battery and wait for power up to end
(see LED Indications table). When prompted for the serial number, activate the sensor (wave a hand in front of the lens) to enroll the sensor. SPECIFICATIONS Power: Battery* (included). 1 x 3 V, Lithium;
CR123A / DL123 / DL 123A / 466 315 MHz 14 to 131 F (-10 to 55 C) Battery Life, years (typical): 5 RF Frequency:
Operating Temperature:
(for indoor use environment) Relative Humidity, no condensation:
Detectable Walk Rate:
Temperature Compensation: Advanced Dual Slope 95% max. 0.7 7ft/Sec. (0.2 2.0m/Sec.)
* Battery Caution: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212 F (100 C), or incinerate. Dispose of used batteries promptly. Keep away from children. APPROVALS / LISTINGS FCC IC C-Tick CE SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. cETLus Listed COMPLIANCE NOTES Product must be tested at least once each year. Product must be installed within the protected area only. FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules and RSS-210 of the IC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la partie 15 des rgles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer dinterfrences nuisibles. (2) Cet appareil doit accepter toute interfrence reue y compris les interfrences causant une rception indsirable. Loop 1 Pulse count 2; Up to 80 lbs. Animal Immunity LED INDICATIONS Condition Power Up Walk Test Indicator LED Blinks once per second (for < 45 seconds) ON for 3 seconds = Loop 1 / Low Sensitivity Alarm Flickers rapidly for 3 seconds = walk test period ended MOUNT THE SENSOR (See page 1) Before mounting the transmitter permanently, conduct Go/No Go tests (see control panel manual) to verify adequate signal strength and reorient or relocate the sensor if necessary. For Animal (Pet) Immunity:
Install the sensor where animals cannot come within 6 ft
(1.8 m) of the sensor by climbing on furniture or other objects. Aim the sensor away from stairways, furniture or other objects that can be climbed on by animals. Do not use optional swivel mount brackets. WALK TESTING The 10 minute walk test mode begins after power up, and can be restarted by removing and replacing the battery. As you walk through the detection pattern, the sensor LED will light for 3 seconds to indicate each alarm detection. Note: In walk test mode all transmissions will be sent as they occur. During normal operation, only one transmission sequence will occur within a 3-minute period to conserve battery life. TROUBLESHOOTING Problem: The system displays a low battery message. Solution: Replace the battery within 7 days. 2009 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico. For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security PRELIMINARY DRAFT 8/24/09
- 2 -
800-13192-
P/N 800-13192 Rev A 10/12