5800FLOOD Flood Detector & Temperature Sensor INSTALLATION INSTRUCTIONS Instructions dinstallation The ADEMCO 5800FLOOD Flood Detector & Temperature Sensor is a wireless transmitter used with Honeywells alarm systems that support 5800 series devices. Applications include bathrooms, laundry rooms, boilers and basements etc. The 5800FLOOD:
Ce contact de porte / fentre sans fil est conu pour tre utilis avec les panneaux de commande Honeywell qui supportent les dispositifs de la srie 5800. Applications include bathrooms, laundry rooms, boilers and basements etc. The 5800FLOOD:
can serve as a hot and/or cold temperature sensor via internal thermal sensor
(sends alarm to control when temperature is lower than 45F (Cold condition) or above 95F, (Hot condition). can serve as a Water leakage or Flood Detector via built-in metal contacts on the bottom of the unit
(sends alarm to control within approximately 40 seconds after water has come in contact with the metal probes.) does not require external probes functions (modes) set by programming pre-defined device loop numbers (see table 1) to separate zones in the control panel. provides tamper supervision, which sends a trouble signal to the control if the units cover is removed. INSTALLATION Check Signal Strength: Before installing permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength from the planned location. Adjust the device location as necessary. Water Leak Detection Place the device on the floor or other desired location near any area that potentially can be subject to a water leak condition
(ex. floor near or inside a kitchen cabinet, near the base of a refrigerator, in a bathroom, basement, etc.). Make sure the metal contacts at the bottom of the enclosure are clean and free of any debris before positioning the unit in place. To ensure the unit remains in place, use the double-sided tape to adhere unit to the floor or other surface. IMPORTANT: After a water leak detection event, make sure the contacts and the unit are completely dry and free of any debris before relocating the device. Temperature Sensing Mount the device low on a wall in the desired location with double-sided adhesive tape (supplied). If used solely as a temperature sensor, the 5800FLOOD can be mounted low on a wall with double-sided adhesive tape
(supplied). can serve as a hot and/or cold temperature sensor via internal thermal sensor
(sends alarm to control when temperature is lower than 45F (Cold condition) or above 95F, (Hot condition). can serve as a Water leakage or Flood Detector via built-in metal contacts on the bottom of the unit
(sends alarm to control within approximately 40 seconds after water has come in contact with the metal probes.) does not require external probes functions (modes) set by programming pre-defined device loop numbers (see table 1) to separate zones in the control panel. provides tamper supervision, which sends a trouble signal to the control if the units cover is removed. INSTALLATION Check Signal Strength: Before installing permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength from the planned location. Adjust the device location as necessary. Water Leak Detection Place the device on the floor or other desired location near any area that potentially can be subject to a water leak condition
(ex. floor near or inside a kitchen cabinet, near the base of a refrigerator, in a bathroom, basement, etc.). Make sure the metal contacts at the bottom of the enclosure are clean and free of any debris before positioning the unit in place. To ensure the unit remains in place, use the double-sided tape to adhere unit to the floor or other surface. IMPORTANT: After a water leak detection event, make sure the contacts and the unit are completely dry and free of any debris before relocating the device. Temperature Sensing Mount the device low on a wall in the desired location with double-sided adhesive tape (supplied). If used solely as a temperature sensor, the 5800FLOOD can be mounted low on a wall with double-sided adhesive tape
(supplied). IMPORTANT:
Do not install this device on or near metal objects, Avoid IMPORTANT:
Do not install this device on or near metal objects, Avoid locating the device near wiring such as AC, telephone, HVAC, computer data cables, etc. locating the device near wiring such as AC, telephone, HVAC, computer data cables, etc. Avoid mounting the detector near heat generating devices
(e.g. ovens, heat vents, furnaces, boilers) or on a metal cabinet. DO NOT remove the circuit board from the back case. PROGRAMMING (Setting the Operating Mode) Table 1 lists the functions of the 5800FLOOD with their respective loop numbers. Program each desired loop function as a separate zone in the control panel. 1. Enter the controls Zone Programming mode. 2. Assign a zone number for each loop used. Loop = 1, 2, or 3 (see table for loop functions) Zone Type = choose a zone type based on desired operation
(ex. 24-Hr. Aux, Waterflow) Input Type = 03 (Supervised RF) 3. When prompted for the serial number, press and release the units tamper switch twice. Alternatively, you can manually enter the sensor serial number found on the units label. Avoid mounting the detector near heat generating devices
(e.g. ovens, heat vents, furnaces, boilers) or on a metal cabinet. DO NOT remove the circuit board from the back case. PROGRAMMING (Setting the Operating Mode) Table 1 lists the functions of the 5800FLOOD with their respective loop numbers. Program each desired loop function as a separate zone in the control panel. 1. Enter the controls Zone Programming mode. 2. Assign a zone number for each loop used. Loop = 1, 2, or 3 (see table for loop functions) Zone Type = choose a zone type based on desired operation
(ex. 24-Hr. Aux, Waterflow) Input Type = 03 (Supervised RF) 3. When prompted for the serial number, press and release the units tamper switch twice. Alternatively, you can manually enter the sensor serial number found on the units label. Table 1 Mode Loop Fault Occurs When After Restore when After Flood Loop 3 probe contacts water 40 sec Temperature is.. no contact with water and contacts are dry Temperature is.. 40 sec Loop 1 below 45F (7C) Loop 2 above 95F (35C) 15 min above 45F (7C) below 95F (35C) 15 min Temperature Cold Hot Table 1 (French) Mode Loop Fault Occurs When After Restore when After no contact with water and contacts are dry Temperature is.. 40 sec Flood Loop 3 probe contacts water 40 sec Temperature Cold Temperature is.. Loop 1 below 45F (7C) above 45F (7C) 15 min below 95F (35C) 15 min Loop 2 above 95F (35C) Hot TESTING 1. With the control panel in Test mode, remove & replace device cover to activate. TESTING 1. With the control panelin Test mode, remove & replace device cover to activate. 2. System keypad should beep and display each programmed 2. System keypad should beep and display each programmed zone (loop). zone (loop). 3. Exit controls test mode. MAINTAINING PROPER OPERATION To maintain the detector in proper working condition, it is important that you observe the following:
Replace the battery when a low battery condition is reported. Make sure the unit is situated flat on the floor, or any other 3. Exit controls test mode. MAINTAINING PROPER OPERATION To maintain the detector in proper working condition, it is important that you observe the following:
Replace the battery when a low battery condition is reported. Make sure the unit is situated flat on the floor, or any other surface and make sure the contacts are not blocked by debris or dirt as these will affect conductivity of water in the area. surface and make sure the contacts are not blocked by debris or dirt as these will affect conductivity of water in the area. Clean and dry the metal probes before reusing the device Clean and dry the metal probes before reusing the device following the water leak detection. following the water leak detection. It is recommended to get the advice of the alarm company to relocate the device. It is recommended to get the advice of the alarm company to relocate the device. BATTERY REPLACEMENT BATTERY REPLACEMENT After removing the battery; wait at least 30 seconds before installing the new one. Use only the following 3V Lithium batteries:
Panasonic CR123A Duracell DL123A Huiderui CR123A Honeywell 466 CAUTION: Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 212F
(100C) or incinerate. Dispose of used batteries properly. Keep away from children. NOTE: Constant exposure to high or low temperature or high humidity may reduce battery life. After removing the battery; wait at least 30 seconds before installing the new one. Use only the following 3V Lithium batteries:
Panasonic CR123A Duracell DL123A Attention de batterie : Risque d'incendie, d'explosion et de brlures. Ne rechargez pas, dmonter, chauffer au-dessus de 212 F (100C), ou incinrer. Dbarrassez-vous des batteries utilises de faon approprie. Gardez partir des enfants. Huiderui CR123A Honeywell 466 NOTE : Une exposition constante des tempratures leves ou basses ou un taux d'humidit leve peut rduire la dure de vie de la pile. 3V Lithium, CR123A
(battery life ~4-5 years) 3A maximum SPECIFICATIONS Battery Type Standby Current Consumption Low Battery Detection 2.8V 20mV Unit (Battery) Shut Down 1.8V 20mV RF Frequency RF Range 344.94MHZ (5800 protocol) 200ft (60m) nominal indoors from wireless transmitters (the actual range to be determined with the security system in the Test mode). Operational Temperature 14F to 104F (-10C to +40C) Cold- Hot Alert detection < 45F for Cold, and 95F for Hot Water Sensing Probes Water Leak Detection Dimensions POUR LES DTAILS CONCERNANT LES LIMITATIONS DU SYSTME DANS SON ENSEMBLE, REPORTEZ-VOUS AUX INSTRUCTIONS DINSTALLATION DU PANNEAU DE COMMANDE AVEC LEQUEL LE DISPOSITIF EST UTILIS.
(<7.2C for Cold, and 35C for Hot) Stainless steel contacts Reports alarm within 30-40 seconds. 3.1 L x 1.6 W x 2.0 D max.
(7.9cm L x 4.1mm W x 5.8mm D max.) SPECIFICATIONS Battery Type Standby Current Consumption Low Battery Detection 2.8V 20mV Unit (Battery) Shut Down 1.8V 20mV RF Frequency RF Range 3V Lithium, CR123A
(battery life ~4-5 years) 3A maximum 344.94MHZ (5800 protocol) 200ft (60m) nominal indoors from wireless transmitters (the actual range to be determined with the security system in the Test mode). Operational Temperature 14F to 104F (-10C to +40C) Cold- Hot Alert detection < 45F for Cold, and 95F for Hot Water Sensing Probes Water Leak Detection Dimensions
(<7.2C for Cold, and 35C for Hot) Stainless steel contacts Reports alarm within 30-40 seconds. 3.1 L x 1.6 W x 2.0 D max.
(7.9cm L x 4.1mm W x 5.8mm D max.) REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. FCC / IC STATEMENT FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC rules and Industry Canadas license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized changes or modifications could void the user's authority to operate the equipment. Cet appareil est conforme la partie 15 des rgles de la FCC & et exempt de licence RSS dIndustrie Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer dinterfrences nuisibles. (2) Cet appareil doit accepter toute interfrence reue y compris les interfrences causant une rception indsirable. Support and Warranty / Soutien et Garantie For online support information, please go to: https://mywebtech.honeywell.com/
Pour de lassistance en ligne, visitez : https://mywebtech.honeywell.com/
For the latest warranty information, go to: www.honeywell.com/security/hsc/resources/wa Pour les dernires informations de garantie, s'il vous plat aller :
www.honeywell.com/security/hsc/resources/wa For patent information, see www.honeywell.com/patents Pour des informations sur les brevets, voir www.honeywell.com/patents MyWebTech Warranty Garantie Patents Brevets Honeywell is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Honeywell des marque dpose de Honeywell International Inc. Toutes les autres marques de commerce appartiennent leurs propritaires respectifs. Tous droits rservs. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 2017 Honeywell International Inc. www.honeywell.com/security 800-23123j 800-23123 8/17 Rev A