69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 1 Friday, April 29, 2011 12:04 PM System Installation Guide TL9160 Wireless Thermostat Kit With Equipment Interface Module Franais : voir la page 25 Espagnol : vea la pgina 49 Installation guide for:
Wireless equipment interface module Wireless remote control Wireless outdoor air sensor TL9160 wireless thermostat IMPORTANT INSTRUCTIONS ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. Must be installed by a trained, experienced technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Need Help?
For assistance with this product please visit http://customer.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 2 Friday, April 29, 2011 12:04 PM Installation Guide System installation at a glance The equipment interface module (EIM) allows you to control a baseboard heater, a convector or a fan-forced heater in 120-volt or 240-volt application from a TL9160 wireless thermostat 1. heater Thermostat Thermostat EIM inside heater Outdoor sensor EIM in remote junction box Electrical panel Remote control Supply wires Wireless connection Installation procedure Install the equipment interface module (EIM)............................................... Pages 3 - 5 Install batteries in wireless devices ..................................................................... Page 6 Link all devices to wireless network ............................................................. Pages 6 - 9 Exit wireless setup ............................................................................................ Page 10 Customize thermostat (installer setup)..................................................... Pages 10 - 17 Mount thermostat and outdoor sensor .............................................................. Page 18 For error codes, see page 19. To verify the signal strength, see page 20. To replace a wireless device, see page 20. For specifications and replacement parts, see page 22. SAVE THESE INSTRUCTIONS 2 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 3 Friday, April 29, 2011 12:04 PM TL9160 Install the Equipment Interface Module (EIM) Determine the location The equipment interface module (EIM) consists of a relay and an antenna. They can be installed either in the wiring compartment of the baseboard heater or in a 4x4 junction box. NOTE: Install EIMs at a minimum distance of 2 feet (0.6 m) of each other. This minimum distance still applies even if the EIMs are on opposite sides of a wall. 2. Installing the EIM in the baseboard heater You can install the EIM in the wiring compartment of the heater if you have any of the heaters listed in the following table:
Relay Antenna Manufacturer / brand Cadet Global Commander King Electrical Marley Ouellet Stelpro TPI NOTE: The product has been tested for compatibility with the heaters listed above. If your heater is not in the list, install the EIM on an electrical box or replace it with one listed. Series F CCB K, CB, KP, M 2500, BKOC, QMKC ODBA, ODI, ODIA, OFM, OPR CBB, N, SCA, SCAS 2900C, 2900S, 3700, 3900 Install the EIM in a 4x4 electrical box Install the EIM in a 4x4 electrical box:
if you have a convector or fan-forced heater. if you cannot install or do not wish to install the EIM in the wiring compartment of the heater. NOTE: The electrical box can be installed anywhere in the house; for example, near the main electrical panel. 3 Relay Antenna 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 4 Friday, April 29, 2011 12:04 PM Installation Guide Installation in the heater ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum. NOTE: First, disconnect the heater wires from the supply wires. If the heater has a built-in thermostat, remove it. 1) Remove the knockout on the side of the heater. 2) Remove the locknut from the antenna and peel off the adhesive backing. Feed the antenna wires through the knockout and install the antenna vertically as shown. Put the locknut and tighten. N L : For 120V application L2 L1 : For 240V application e e u u B B l l d d e e R R k k c c a a B B l l 3) Peel off the adhesive backing of the relay and stick the relay on the back panel inside the wiring compartment with the relay wires directed upwards. 4) Connect the heater wires and the supply wires to the relay wires as shown. 5) Insert the antenna plug into the relay receptacle until you hear a click. Install plug if applicable. 6) Put the heater cover back. (If a built-in thermostat was removed, install one of the supplied plugs to cover the hole on the existing cover.) Apply power to the heater. Do not install the antenna cover yet. 4 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 5 Friday, April 29, 2011 12:04 PM Installation in a 4x4 junction box TL9160 ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if the supply wires are made of aluminum. 1) Mount the junction box on the wall. Punch out a knockout on the side of the electrical box where the AC wires come in. Punch out another one or two knockouts for the heater and supply wires. Install strain relief bushings. 2) Remove the locknut from the antenna and peel off the adhesive backing. Feed the antenna wires through a knockout and mount the antenna vertically as shown. Put the locknut and tighten. N L : For 120V application L2 L1 : For 240V application e e u u B B l l d d e e R R k k c c a a B B l l To heater 3) Peel off the adhesive backing of the relay module and stick the relay inside the electrical box with the relay wires directed upwards (as shown). 4) Feed the supply wires and heater wires through a knockout and connect them to the relay module. 5) Insert the antenna plug in the relay receptacle until you hear a click. Install a cover plate and apply power to the heater. Do not put the antenna cover back yet. 6) 5 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 6 Friday, April 29, 2011 12:04 PM Installation Guide Install batteries in wireless devices Thermostat Remote control Outdoor air sensor Install 2 AA alkaline batteries Install 3 AA alkaline batteries Install 2 AA lithium batteries Link all devices to wireless network Start wireless setup Press the CONNECT button on the antenna to place it in wireless setup. When the amber light changes to a green flashing light, you can begin to link devices to the wireless network
(see pages 7-10). NOTE 1: If the amber light changes to a red light instead, there is another EIM currently in wireless setup. Press the CONNECT button on the other EIM to exit its wireless setup. NOTE 2: If the green flashing light disappears
(after a delay of 15 minutes) before you have time to link all your devices, press the CONNECT button again. Press and release LED *
* Flashing green: Ready for connection Steady green: Connection established Steady red: Connection failure 3. 4. 6 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 7 Friday, April 29, 2011 12:04 PM TL9160 Link thermostat and EIM to wireless network Perform the following steps on the thermostat:
NOTE: You can skip step 2 if you do not have a wireless remote control or do not have more than one wireless thermostat in your house.
#
Display Button Step 1) 2) 3) 4) The Link menu appears when you connect the thermostat to wireless network for the first time. Press OK to select Zone. or Press to change the zone name (see page 15) and press OK. Press OK to select Connect. DONE confirms the connection is successful. Press Exit once to link another EIM (see page 8) or 3 times to return to home screen. 7 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 8 Friday, April 29, 2011 12:04 PM Installation Guide Link additional EIM to wireless network (if applicable) NOTE: Perform steps 1 to 6 for each additional EIM. You can link a maximum of 8 EIMs to the wireless neywork. 1) If the green light on the EIM that was last linked is still flashing, press its CONNECT button. The green light will become steady. 2) Press the CONNECT button on the next EIM you wish to link and wait for its green flashing light. NOTE: Skip steps 3 and 4 if the Link menu is still displayed on the thermostat (as shown in step 5).
#
3) 4) 5) 6) Display Button Step Press and hold the right center button for 5 secs. From the installers setup menu, press to select Link and press OK. If necessary, press select Connect More and press OK. to DONE appears to confirm the connection is successful. Press Exit and go back to step 1 once to link another EIM or 3 times to return to home screen. 8 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 9 Friday, April 29, 2011 12:04 PM TL9160 Link outdoor sensor to wireless network (if applicable) 1) Make sure the green light on the EIM is flashing;
this indicates the wireless setup is still active. If not, activate the wireless setup (see page 6). NOTE: If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM connected to the same network as the thermostat. For example, to display the outdoor temperature on thermostat Y, you can activate the wireless setup from either EIM B or C, not A. Press and release 2) Press the CONNECT button on the back of the sensor. 3) After 15 seconds, check if the thermostat is displaying a value for the outdoor temperature reading. NOTE: If you have more than one wireless thermostat, repeat steps 1 and 3 for each thermostat. Bathroom wireless network Bedroom wireless network Outdoor sensor Thermostat X Thermostat Y EIM A Remote control EIM B EIM C Link remote control to wireless network (if applicable) 1) Make sure the green light on the EIM is flashing, which indicates the wireless setup is still active. If not, activate the wireless setup (see page 6). NOTE: If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM connected to the same network as the thermostat. For example, to link the remote control to thermostat Y, you can activate the wireless setup from either EIM B or C, not A. 2) Refer to the remote control guide for connection to the wireless network. 9 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 10 Friday, April 29, 2011 12:04 PM Installation Guide Exit wireless setup 1) Press the CONNECT button at the EIM. The green flashing light on the antenna will change to a steady green light. NOTE: If you do not press the CONNECT button, the EIM will automatically exit wireless setup after 15 minutes of inactivity. 2) Put the cover back on the antenna module. 5. 6. Customize the thermostat Hidden installers setup menu button To display the installers setup menu from the home screen, press and hold the right center button for 5 secs. OK button Press OK to accept the setting on the screen and move to the next parameter or menu. NOTE: Pressing OK saves the new setting or confirms you accept the current setting. Exit button Press Exit to return to the previous menu or to the home screen. NOTE: If you press Exit right after changing a setting, the new setting will not be saved. Make sure you press OK to save the new setting before you press Exit. 10 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 11 Friday, April 29, 2011 12:04 PM TL9160 F 12h To modify, see Default setting Choices C / F 12h / 24h Default settings Parameter Temperature unit Time format Minimum setpoint Maximum setpoint Anti-freeze Lock Zone Adaptive Intelligent Recovery Schedule NOTE: To set the date & time, the schedule and the automatic daylight savings, refer to Users Guide. Page 11 Page 11 Page 12 Page 12 Page 13 On None 52 On On Pages 13-14 Pages 14-15 1, ..., 57 On / Off On / Off 41F (5C) 86F (30C) Page 16 Page 17 None / Partial / All On / Off Temperature unit / Time format Follow this procedure to select the temperature unit (C or F) and time format (12h or 24h). NOTE: The time format selection is available only if the thermostat is in programmable mode.
#
1) Display Button Step From the installers setup menu, press OK to select the Format menu. 2) 3) If necessary, press to change the temperature unit. Press OK. or If necessary, press to change the time format. Press OK. or 11 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 12 Friday, April 29, 2011 12:04 PM Installation Guide Minimum and maximum setpoints Follow this procedure to set the minimum and maximum setpoint temperature.
#
1) Display Button Step From the installers setup menu, press to select Setpoints and press OK. 2) 3) 4) 5) 6) Press OK to select Min. If necessary, press or to change the minimum setpoint. Press OK. Press OK to select Max. If necessary, press or to change the maximum setpoint. Press OK.
(Pressing Exit will cancel the change.) Press Exit once to return to installers setup menu or twice to return to home screen. 12 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 13 Friday, April 29, 2011 12:04 PM TL9160 Anti-freeze When this function is on, the EIM will maintain the room temperature at 55F (13C) if it loses communication with the thermostat or if the thermostat sensor is defective. The protection automatically turns on when the EIM is linked to the thermostat. Leave the protection on unless the EIM is installed in a junction box in a separate room from the heater. To turn off the protection, proceed as follows:
#
1) Display Button Step From the installers setup menu, press as needed to select Anti-Freeze and press OK. 2) 3) Lock By default, the setting lock is disabled. or Press OFF. Press OK. to set to Press Exit once to return to installers setup menu or twice to return to home screen. If you leave at None, you have full access to all thermostat settings. If you select Part (Partial), you can change the room temperature only. If you select All, no button is available. You cannot change any setting except for the installers setup menu. 13 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 14 Friday, April 29, 2011 12:04 PM Installation Guide
#
1) 2) 3) Display Button Step From the installers setup menu, press to select Lock and press OK. to select All, or Press Part (partial) or None. Press OK. Press Exit once to return to installers setup menu or twice to return to home screen. Zone The zone name is used to identify the thermostat on the wireless remote control. By default, the zone name of the thermostat is Thermostat (zone 52). If you have a wireless remote control and several wireless thermostats, change the zone name of the thermostat to identify it from the other thermostats. For example, if the thermostat is in the living room, set the zone to 31.
#
1) Display Button Step From the installers setup menu, press to select Link and press OK. 2) Press OK to select Zone. 14 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 15 Friday, April 29, 2011 12:04 PM TL9160 3) 4) Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 or Press value. Press OK. to set the Press Exit once to return to installers setup menu or twice to return to home screen. Name Basement Bathroom Bathroom 1 Bathroom 2 Bathroom 3 Bedroom Bedroom 1 Bedroom 2 Bedroom 3 Bedroom 4 Boat House Bonus Room Computer Room Den Dining Room Zone 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Name Exercise Room Family Room Fireplace Foyer Game Room Garage Great Room Guest Room Gym Kid's Room Kitchen Kitchen 1 Kitchen 2 Laundry Room Zone 30 31 32 33 34 35 36 37 38 39 40 41 42 43 Name Library Living Room Lower Level Master Bath Master Bed Media Room Music Room Nursery Office Office 1 Office 2 Pantry Play Room Pool Room Name Porch Rec Room Sewing Room Spa Storage Room Studio Sun Room Theater Thermostat Upper Level Utility Room Zone 44 45 46 47 48 49 50 51 52 53 54 55 Walk In Closet 56 Wine Cellar 57 Workshop 15 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 16 Friday, April 29, 2011 12:04 PM Installation Guide Adaptive Intelligent Recovery Available only if you use the thermostat in programmable mode. When Adaptive Intelligent Recovery is on, the thermostat learns how long your heater takes to reach the set temperature. The thermostat will then determine when to activate heating so the desired temperature is attained at the desired time. The thermostat re-assesses the heating start time daily based on the previous days performance. When Adaptive Intelligent Recovery is off, heating starts at the set time.
#
1) Display Button Step From the installers setup menu, press to select Recovery and press OK. 2) 3) or Press and press OK. to select Off Press Exit to return to home menu. Schedule The thermostat is factory-set as a 7-day programmable thermostat. To set it as a non-programmable thermostat, proceed as follows:
Display
#
1) Button Step From the installers setup menu, press to select Schedule and press OK. 2) 16 or Press and press OK. to select Off 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 17 Friday, April 29, 2011 12:04 PM TL9160 Copy Use this function to copy the configuration settings, the schedule settings or both to the other wireless thermostats if you have several wireless thermostats in your house. This function is available only if the thermostat is connected either to a remote control or to an outdoor sensor. The parameters are copied to the other thermostats that are also connected to the remote control or to the outdoor sensor.
#
1) Display Button Step From the installers setup menu, press as needed to select Copy and press OK. or to select Press Schedule, Configuration or both (Schedule Configuration). Press OK. Wait may appear for several minutes. When the installers setup menu appears, press Exit to return to home menu. 2) 3) System test 1) Set the temperature above the room ambient temperature. 2. Wait for Heat On to display on the thermostat. 3. Verify if the heater can become hot . 4. Press Cancel. 17 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 18 Friday, April 29, 2011 12:04 PM Installation Guide Mount thermostat and outdoor sensor Follow the guidelines below when mounting the thermostat:
Do NOT install the thermostat in an area where it can be exposed to water or rain. Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes. Install the thermostat on an inside wall facing the heater. For a new installation, choose a location about 1.5 m (5 ft.) above the floor. Keep the thermostat's top and bottom air vents (openings) clean and unobstructed at all times. Two mounting plates are provided for mounting the thermostat on the wall or on a junction box. 7. 1) Recessed mounting on a wall 1a) Mark the four corners and join them to create a rectangular outline. 1b) Cut along the outline to create an opening in the wall. 1c) Secure the mounting plate to the wall using provided wall anchors and screws. 1) Mounting on a wall 1) Mounting on a junction box 2) Installing faceplate Secure the mounting plate to the wall using provided wall anchors and screws. Secure the mounting plate to a junction box using provided mechanical screws. Use the mounting plate that has no center opening. Complete the thermostat installation by pressing the faceplate against the mounting plate. 18 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 19 Friday, April 29, 2011 12:04 PM TL9160 3) Install the outdoor sensor (optional) Press and release Hold sensor where you intend to install it and press the CONNECT button. If sensor is communicating with the thermostat, the latter will display the outdoor temperature. Mount the sensor vertically on an exterior wall, at least 6 inches below any overhang. Choose a location protected from direct sunlight. Error codes Display Description Place sensor securely in bracket, facing away from wall. 8. LO HI
- -
E27 E128 E129 E130 E134 E137 E138 E152 The indoor temperature is below 0C (32F). The indoor temperature is above 60C (140F). The temperature reading is currently unavailable or the sensor is defective. If the error does not clear after 15 seconds, the thermostat is defective and must be replaced. Call customer assistance. The wireless network setup must be redone. Attempting to connect incompatible wireless devices. Invalid address. Call customer assistance. Low signal strength. Move wireless device to a different location and try again. Maximum number of devices is exceeded. Make sure Connected light on EIM is flashing and you are 2+ feet away from EIM. Incorrect order 19 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 20 Friday, April 29, 2011 12:04 PM Installation Guide Verifying the signal strength between the EIM and the thermostat9. NOTE: If you have several EIMs linked to the thermostat, the displayed value is between the thermostat and the first linked EIM. The signal strength ranges from 0 (no signal) to 10 (strongest).
#
1) Display Button Step 2) 3) 5) From the home screen, press and hold the right center button for 5 secs. to select Link and Press press OK. to select Press Strength and press OK. The signal strength is displayed. Press Exit once to return to installers setup menu or twice to return to home screen. Replacing wireless devices Thermostat To replace the thermostat, install batteries in the new thermostat (see page 6) and link it to the wireless network (see page 6). To customize the thermostat, see page 10. NOTE: If you have more than one EIM in the wireless network, you can link the thermostat from any of the EIMs. Remote control or outdoor sensor To replace the remote control or the outdoor sensor, install batteries in the new device (see page 6) and link it to the wireless network (see page 9). 10. 20 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 21 Friday, April 29, 2011 12:04 PM TL9160 NOTE 1: If you have more than one EIM in the wireless network, you can link the wireless device from any of the EIMs. NOTE 2: If you have more than one wireless thermostat, link the remote control or the outdoor sensor to the wireless network of each wireless thermostat. Equipment interface module (EIM) To replace an EIM, undo the current network and create a new one as follows:
NOTE: Skip steps 1 and 2 if you have only one EIM in the wireless network. 1) Remove the antenna cover from each EIM in the network: place one finger on the top and another finger on the bottom (as shown by red arrows), squeeze the cover and pull it out. 2) Press, for 10 seconds, the CONNECT button on any EIM that has a green light. Repeat this step until the green light on every EIM in the network is off. If the thermostat displays 0 device connected as shown on the right, go to step 7. Otherwise proceed with steps 4 to 6. 3) Display Button Step From the home screen, press and hold the right center button for 5 secs. to select Link and Press press OK. to select Remove Press and press OK. The thermostat will display 0 device connected.
#
4) 5) 6) 7) If you have a remote control, remove its link from the wireless network. (This will also remove the remote control link to any other wireless network.) 8) Remove the defective EIM and install a new one (see pages 3 - 5). 9) Create a wireless network and link all wireless devices (EIM, thermostat, outdoor sensor and remote control). See pages 6 to 10. 21 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 22 Friday, April 29, 2011 12:04 PM Installation Guide Specifications & replacement parts Thermostat Temperature setpoint range:
Temperature setpoint resolution:
Temperature display range:
Temperature display resolution:
Heating cycle rate:
Programming:
41F - 86F (5C - 30C) 1F (0.5C) 32F - 104F (0C - 40C) 1F/ 0.5C standard 15 minutes 5-2 days, 7 days, 1 day or Non-Programmable 11. Operating Ambient Temperature Thermostat:
Remote control:
EIM (relay):
EIM (antenna):
Outdoor air sensor:
Operating Relative Humidity Thermostat:
Remote control:
EIM (relay):
EIM (antenna):
Outdoor air sensor:
32F - 122F (0C - 50C) 32F - 120F (0C - 48.9C)
-4F - 158F (-20C - 70C)
-4F - 158F (-20C - 70C)
-40F - 140F (-40C - 60C) 5% - 90% (non-condensing) 5% - 90% (non-condensing) 5% - 95% (non-condensing) 5% - 95% (non-condensing) 0% - 100% (condensing) Physical Dimensions (height, width, depth) Thermostat:
EIM (relay):
EIM (antenna):
Outdoor air sensor:
Electrical Ratings (EIM) Supply:
Minimum load:
Maximum load:
5.13 x 3.22 x 1.14 inches (130 x 82 x 29 mm) 3.03 x 2.49 x 1.28 inches (73 x 63 x 29 mm) 2.89 x 2.63 x 1.16 inches (71 x 62 x 33 mm) 5.00 x 3.50 x 1.68 inches (127 x 89 x 43 mm) 120/208/240 VAC, 50/60 Hz 0.4 A (resistive only) 12.5 A (resistive only) Accessories & Replacement Parts Item Equipment Interface Module (EIM) Remote control Outdoor air sensor Antenna cover (white) Antenna cover (almond) Part Number TLM1110R1000 REM5000R1001 C7089R1013 50055751-002 50055751-004 22 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 23 Friday, April 29, 2011 12:04 PM TL9160 Regulatory information FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) 2) This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Increase the separation between the equipment and receiver. Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. EIM, thermostats and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Remote control This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Section 7.1.3 of RSS-GEN Operation is subject to the following two conditions:
1) This device may not cause interference, and 2) This device must accept any interference, including interference that may cause undesired operation of the device. Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that necessary for successful communication. 23 69-2474EFS (Honeywell YTL9160 System Installation Guide).book Page 24 Friday, April 29, 2011 12:04 PM