submitted | available | document details (if available) | source link |
---|---|---|---|
69-2427EFS-01 - MRCH1 Remote Controller Technical Communications Adobe PDF Library 8.0 |
various | Manual 1 | Users Manual | 3.72 MiB |
Operating Manual Operating Manual MRCH1 Remote Controller 69-2427EFS-01 Quick Reference Card Grasp and pull to see basic operating instructions at a glance. Battery Holder Press down and pull to remove batteries. Batteries should be replaced once a year
(see page 28). CAUTION: EQUIPMENT DAMAGE HAZARD. Please refer to the equipment Operating Manual for recommended operating temperatures. M28450A Need Help?
For assistance with this product please visit http://controls.mehvac.com or call Mitsubishi Electric toll-free at 888-990-7546 Read and save these instructions. 2010 Mitsubishi Electric & Electronics USA, Inc. Suwanee, GA 30024. Patents pending. All Rights Reserved. The three diamond logo is a registered trademark of Mitsubishi Electric Corporation www.mitsubishipro.com Franais : voir la page 34 Espaol: vea la pgina 68 Appendices Advanced functions......................... 24 Battery replacement ........................ 28 In case of difficulty .......................... 31 Regulatory information .................... 32 Limited warranty .............................. 33 Contents About your new remote controller Programming at a glance .................. 2 Quick reference to controls .............. 3 Quick reference to display screen .... 4 Programming & Operation Set the time and day ......................... 5 Select the fan setting ........................ 6 Select the system setting.................. 7 Multi-zone configurations ................. 8 Drying mode ...................................... 9 Program schedules ......................... 10 Program schedule overrides ........... 13 System changeover ......................... 17 Portable Central Controller ............. 18 Outdoor air sensor .......................... 19 Additional features .......................... 20 1 69-2427EFS01 Operating Manual About your remote controller Your new remote controller is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed:
1. 2. 3. 4. Set time and day (required for proper operation) Select fan setting Select system setting Program schedules:
while space is occupied (assumes arrival at 8 am and departure at 10 pm) ................................................................ See pages 10-11
.......................... See page 5
................................................................................. See page 6
.......................................................................... See page 7 Preset to energy-saving levels ONE TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 13-16). 69-2427EFS01 2 Franais : voir la page 34 Espaol: vea la pgina 68 Quick reference to controls Digital display (see page 4) Temperature buttons Press to adjust temperature settings Battery holder (see page 28) Function buttons Press to select the function displayed just above each button.
(Functions change depending on the task.) M28451A Hold button Press to override programmed temperature control (see page 16) 3 69-2427EFS01 Operating Manual Quick reference to display screen Optimal Start
(see page 23) Current inside temperature Current program period occupied/unoccupied or Wake/Leave/Return/Sleep
(see pages 10-11) Set Clock/Day/
Schedule
(see pages 5 and 12) Low battery warnings
(see page 28) Current time
(see page 5) Recovery Indoor ReplaceBattery Heat Setting Temperature setting
(see pages 1216) occupied1 Set Clock/Day Schedule Fan Auto AM System Heat Locked
(see page 23) More
(see pages 2023) Locked More M32209 Fan Setting Auto/On/Selectable
(see page 6) System setting Cool/Heat/Drying/Auto/Off (see page 7) Note: Options may vary depending on your equipment. 69-2427EFS01 4 Franais : voir la page 34 Espaol: vea la pgina 68 1. 2. 3. Set the time and day Press SET CLOCK/DAY/SCHEDULE, then adjust time Set Clock/Day Schedule Fan Auto System Heat More M32218 Press SET DAY, then select current day Set Day Set Day Mo Done Set Schedule M32211 SET CLOCK/DAY/SCHEDULE, then Press press s or t to set clock. Press select the day of week. Press DONE to save. SET DAY, then press s or t to Note: If the SET CLOCK/DAY/SCHEDULE option is not displayed, press DONE or CANCEL. Note: If the display flashes Set Clock, the remote controller will follow your settings for the weekday occupied1 (or Wake) time period until you reset the time and day. 5 69-2427EFS01 Operating Manual Select the fan setting Set Clock/Day Schedule Fan Auto System Heat Fan System Lo Hi Heat Set Clock/Day Schedule Press FAN to select Auto or selectable fan speed. In Auto fan mode the equipment deter-
mines the optimal fan speed to meet the set temperature. When system switch is Off, press FAN to circulate air. The fan will run at the users selected fan speed. More M32212 More M32213 Note: Selectable fan speed options may vary depending on your equipment. 69-2427EFS01 6 Franais : voir la page 34 Espaol: vea la pgina 68 Select the system setting Fan Auto Fan Auto Fan Auto System Cool System Heat System Drying Fan Auto System Auto Set Clock/Day Schedule Set Clock/Day Schedule Set Clock/Day Schedule Set Clock/Day Schedule More M32214 More M32215 More M32300 More M32301 Press SYSTEM to select:
Cool: Remote controller controls only in the cooling mode. Heat: Remote controller controls only in the heating mode. Drying: Remote controller directs indoor unit to remove moisture out of the air. May result in temperatures below your cool setting. Auto: Remote controller automatically selects heating or cooling depending on the indoor temperature. Off: Indoor unit is off. Note: Options may vary depending on your equipment. 7 69-2427EFS01 Operating Manual Multi-zone configurations Indoor Wait Heat Setting occupied1 Set Clock/Day Schedule Fan Auto AM System Heat More M28946 In multi-zone configurations, each zone is typically set to the same mode (Cool, Heat, or Drying). If zones are set to different modes, the first indoor unit to call for heat or cool will take priority. Other zones go into standby, and Wait will be displayed on the screen. 69-2427EFS01 8 Franais : voir la page 34 Espaol: vea la pgina 68 Drying mode (if configured) Set Clock/Day Schedule Fan Auto System Drying More M28947 Drying mode removes moisture from the air and works differently depending on the type of equipment installed. The tem-
perature setting might or might not be displayed. The indoor unit will determine the Drying mode temperature setting. The setting will be either:
the cool temperature setting, or 3F (2C) below room temperature. 9 69-2427EFS01 Operating Manual Commercial program default settings This remote controller is pre-set to use energy saving program settings. We recom-
mend these settings, since they can reduce your heating/cooling expenses. (See page 12 to adjust times and temperatures of each time period.) Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) occupied1
(8:00 am) unoccupied1
(10:00 pm) occupied 2 unoccupied 2 70 55
--
--
75 85
--
--
70 55
--
--
75 85
--
--
occupied 2 and unoccupied 2 periods may be programmed as needed, depending on installed configuration. 69-2427EFS01 10 Franais : voir la page 34 Espaol: vea la pgina 68 Residential program default settings This remote controller is pre-programmed to use commercial energy saving program settings. For use in a home, change the program to match your schedule. (See page 12 to adjust times and temperatures of each time period.) Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) Wake
(8:00 am) Leave
(10:00 pm) Return Sleep 70 55
--
--
75 85
--
--
(or cancel period) 70 55
--
--
(or cancel period) 75 85
--
--
May cancel Leave, Return and Sleep periods. 11 69-2427EFS01 Operating Manual To adjust program schedules Set Clock/Day Schedule Fan Auto System Heat Set Day Done More M32218 Set Schedule M32219 1. Press SET CLOCK/DAY/SCHEDULE, then SET SCHEDULE. 2. Press s or t to set your weekday occupied1/Wake time (MonFri), then press NEXT. 3. Press s or t to set the heat temperature for this time period, then press NEXT. 4. Press s or t to set the cool temperature for this time period, then press NEXT. 5. Set time and temperature for the next time period (unoccupied1/Leave). Repeat steps 4 and 5 for each weekday time period. 6. Press NEXT to set weekend time periods (Sat-
Sun), then press DONE to save & exit. Note: You may cancel a period using the CANCEL PERIOD button. If configured, you may power the system completely off during the period by using the POWER OFF PERIOD button. 69-2427EFS01 12 Franais : voir la page 34 Espaol: vea la pgina 68 Schedule override (commercial only) Press to temporarily adjust temperature. Indoor Indoor75 Cancel Cancel Fan Auto Fan Auto Hold PM Hold Until 6:00 System System Auto Heat PM Heat Cool Setting Setting 75 More More M32221 M28461 Press to resume program schedule If a person is present during an unoccupied period, press HOLD to temporarily use occupied tempera-
ture. Each additional press of HOLD extends the HOLD UNTIL duration by 1 hour to a limit set by the installer. The timer will expire automati-
cally or schedule may be manually resumed by pressing CANCEL. Note: Permanent hold not available on commercial configuration. 13 69-2427EFS01 Operating Manual Holiday override (commercial only) Hold Until Days Hold Until Days Done Done Reset 69-2427EFS01 If the building will be unoccupied for more than one day, you can use Holiday override to main-
tain an unoccupied temperature. Press MORE until the Hold Until screen appears. Press s or t to set the number of days, then press NEXT. Press s or t to set the heat or cool tempera-
ture setting, then press DONE. The cool temperature setting can only be set higher and the heat temperature setting can only be set lower than the unoccupied program schedule. To clear the Holiday override from the home screen, press CANCEL. 14 M28948 Cool Setting Select Heat/Cool M28950 Franais : voir la page 34 Espaol: vea la pgina 68 Temporary hold (residential only) Press to temporarily adjust temperature. Indoor Hold Until PM Cancel Fan Auto System Auto Cool Setting More M32221 Press to resume program schedule Temperature will be maintained until the time shown Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. The new temperature will be maintained only until the next programmed time period begins (see page 11). To cancel the temporary setting at any time, press CANCEL. 15 69-2427EFS01 Operating Manual Permanent hold (residential only) Press to permanently adjust temperature. Hold Hold Heat Setting Cool Setting 75 Indoor Indoor75 Cancel Cancel Fan Fan Auto Auto PM PM 6:00 System System Auto Heat More More M32222 M28461 Press to resume program schedule 69-2427EFS01 Temperature will be maintained until CANCEL button is pressed. 16 Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods. The HOLD feature turns off the program schedule and allows you to adjust the temperature manually, as needed. The system will maintain the set temperature until you manually change it or you press CANCEL to resume the program schedule. System Changeover Fan Auto System Auto Set Clock/Day Schedule Press until screen displays Auto Franais : voir la page 34 Espaol: vea la pgina 68 More M32217 System Changeover is a feature used in climates where both air conditioning and heating are often used on the same day. When the system is set to Auto, the remote controller automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 2 degrees apart, depending how your remote con-
troller was configured. The remote controller will automatically adjust settings to maintain this 2
(or more) degree separation. Note: The Auto system setting may not appear, depending on how your remote controller was configured. 17 69-2427EFS01 Operating Manual Portable Central Controller (optional) The optional Portable Central Controller can manage temperatures of multiple split-zoning systems from almost anywhere on the property. The Portable Central Controller also works with other RedLINK devices used with other types of heating and cooling equipment. One Portable Comfort Control can adjust up to 16 zones on a single property. Note: The remote controller may take up to 15 seconds to respond to commands entered at the Portable Central Controller. 69-2427EFS01 18 Outdoor air sensor (optional) Franais : voir la page 34 Espaol: vea la pgina 68 The outdoor air sensor allows outdoor air temperature and humidity to be shown on your remote controller. The outdoor air sensor also works with other RedLINK devices used with other types of heating and cooling equipment. Only use AA lithium batteries for the outdoor air sensor. 19 69-2427EFS01 Operating Manual Remote Controller additional features To display outdoor temperature and humidity If you have an outdoor air sensor, press MORE to display the current outdoor temperature and humidity. Press DONE to exit. Outdoor Outdoor Humidity Done FindRemote More M32302 To find a lost Portable Central Controller If you misplace a Portable Central Controller, press MORE, then FIND REMOTE. The Portable Central Controller will beep for two minutes to help you locate it. Press anywhere on the display screen of the Portable Central Controller to stop the beeping. 69-2427EFS01 20 Remote Controller additional features (continued) Franais : voir la page 34 Espaol: vea la pgina 68 To set up/down airflow direction
(vane control) If you would like to manually set the airflow direction, press MORE, then s or t to select the desired posi-
tion, Auto or Oscillate. Ceiling Set Airflow Direction Floor Done M32305 Note: Auto position is determined by the system equipment to provide maxi-
mum efficiency and comfort. Top and bottom positions may change after 1 hour to prevent condensation. Note: Airflow direction positions may vary depending on your equipment. 21 69-2427EFS01 Operating Manual Remote Controller additional features (continued) Set a timer to automatically power off the indoor unit (if configured) Press MORE until Power Off At is displayed. Press s or t to set the time at which you would like the unit to turn off. Press DONE to exit. Note: This is not a recurring timer. This timer can be set up to 24 hours in advance. Depending on how this feature was installed, the indoor unit will either:
A) Stay turned Off indefinitely until the user changes the system mode. B) Stay turned Off until the next scheduled period Example:
If a room will be unoccupied at 10:00 PM, press MORE until Power Off At appears. Press s until 10:00 PM. Press DONE to exit. To clear the Power Off At timer from the home screen, press CANCEL. Heat Setting Power at:
Off Indoor PM Fan Auto System Auto Cancel 69-2427EFS01 22 More M32304 Franais : voir la page 34 Espaol: vea la pgina 68 Remote Controller additional features (continued) Optimal Start: This feature eliminates the guesswork when setting your schedule. It allows the remote controller to learn how long your Split-Zoning System takes to reach programmed temperature settings, so the temperature is reached at the time you set. Locked: To prevent tampering, features can be fully or partially locked. When a selected feature is locked, the word Locked is displayed on the screen for approximately 5 seconds. Reset Clean Filter: When Remote Controller is flashing Clean Filter, press More and then press Reset. See page 25 to change or remove filter timer. Clean Filter 23 69-2427EFS01 Done Reset More M28980 Operating Manual Advanced functions Press and hold the MORE button until the display changes. WAIT will be displayed for up to 40 seconds. Function Option More M289872 Done Back Next M32303 Press DONE to save & exit. WAIT will be displayed for up to 30 seconds. Press s or t to change option
(see pages 25-27). Press NEXT to display next function screen
(see pages 25-27). M28488A 69-2427EFS01 24 Franais : voir la page 34 Espaol: vea la pgina 68 Advanced functions Press s/t to change option, then press NEXT. Filter Change Reminder Function 107 Options:
This feature displays an alert to remind you to change the filter in the indoor unit. 1 = 100 Hours 2 = 2500 Hours 3 = OFF (no reminder to change filter) Fahrenheit or Celsius Display Function 139 Options:
Press s/t to change the display. 0 = Fahrenheit 1 = Celsius Schedule Format Function 148 Options:
Press s/t to change the schedule format. 0 = 5-2 (Monday Friday) (Sat-Sun) 1 = 5-1-1 (Monday Friday) (Sat) (Sun) Optimal Start Function 150 Options:
See page 23 for description of feature. 1 = ON 0 = OFF 25 69-2427EFS01 Operating Manual Advanced functions Full Lockout Function 160 Options:
This feature prevents users from changing all settings. 0 = No 1 = Yes Lockout On/Off Function 162 Options:
This feature prevents users from changing the system setting to OFF. 0 = No 1 = Yes Lockout System Mode Function 164 Options:
This feature prevents users from changing the system setting to Heat, Cool, Auto, Drying. 0 = No 1 = Yes Lockout Fan Mode Function 165 Options:
This feature prevents users from changing the fan setting. 0 = No 1 = Yes 69-2427EFS01 26 Franais : voir la page 34 Espaol: vea la pgina 68 Advanced functions Lockout Temperature Setting Function 166 Options:
This feature prevents users from changing the temperature setting. 0 = No 1 = Yes Lockout Set Clock/Day/Schedule Function 168 Options:
This feature prevents users from changing the clock, current day and the schedule. 0 = No 1 = Yes Maximum Heat Temperature Setting Allowed Function 170 Options:
This feature prevents users from changing the Heat temperature setting above the selected temperature limit. Temperature setting range may vary based on equipment installed. 90 = 90F (32C) Temperature Limit 40-89 = 40 to 89F (4.5 to 31.5C) Minimum Cool Temperature Setting Allowed Function 172 This feature prevents users from changing the Cool temperature setting below the selected temperature limit. Temperature setting range may vary based on equipment installed. 50 = 50F (10C) Temperature Limit 51-99 = 51 to 99F (10.5 to 37C) 27 69-2427EFS01 Options:
Operating Manual Battery replacement (remote controller) Press down and pull to remove. Replace Battery M28466A Insert fresh AA alkaline batteries, then reinstall battery holder. Install fresh batteries when the REPLACE BATTERY warning begins flashing. The warning flashes about two months before the batteries are depleted. Remove the battery holder and install 2 fresh AA alkaline batteries. Do not use rechargeable batteries. After batteries are installed, the remote controller will automatically restore communication with the wireless network within a few minutes. Note: If batteries are inserted within 2 minutes, the time and day will not have to be reset. All other settings are retained in memory. 69-2427EFS01 M28442 M28442 28 Battery replacement (Portable Central Controller) Franais : voir la page 34 Espaol: vea la pgina 68 Install fresh batteries when the REPLACE BATTERY warning begins flashing. The warning flashes about two months before the batteries are depleted. Remove the battery cover and install 3 fresh AA alkaline batteries. Do not use rechargeable batteries. After batteries are installed, the Portable Central Controller will automatically restore communication with the wireless network within a few minutes. M28475 29 69-2427EFS01 Operating Manual Battery replacement (outdoor air sensor) Remove sensor from bracket M28443A Remove cover and install 2 fresh AA lithium batteries 69-2427EFS01 Replace outdoor sensor batteries when the Replace Battery Outdoor warning begins flashing on the remote controller. The warning flashes about two months before the batteries are depleted. Remove the sensor from the bracket, remove the cover and install 2 fresh AA lithium batteries. Do not use rechargeable batteries. After batteries are installed, the sensor will automatically restore communication with the wireless network within a few minutes. M28444 M28444 30 Franais : voir la page 34 Espaol: vea la pgina 68 In case of difficulty Indoor unit does not respond Check circuit breaker and reset if necessary. Make sure power switch at equipment is on. Wait 5 minutes for the system to respond. Remote contoller has lost radio contact with the wireless network (usually because of a power outage). To restore power:
Check circuit breaker and reset if necessary. Make sure power switch at indoor unit is on. After power is restored, the remote controller will automatically restore wireless communication within a few minutes. The system requires a minimum on time for component protection. Please wait up to 6 minutes. Screen displays No Signal Displayed indoor temperature is above/below temperature setting 31 69-2427EFS01 Operating Manual Regulatory information FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1 2 This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Wireless receiver, remote controller and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Portable Central Controller This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/
uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter. Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions:
this device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device. 1 2 69-2427EFS01 32 Franais : voir la page 34 Espaol: vea la pgina 68 Limited warranty Refer to warranty statement in equipment documentation. 33 69-2427EFS01 Aide-mmoire Tirer sur la carte pour voir les instructions de base en un coup dil. Support des piles Appuyer et tirer sur le support pour retirer les piles. Les piles doivent tre remplaces une fois par an (voir page 62). MISE EN GARDE : RISQUE DE DOMMAGES DE LQUIPEMENT. Merci de consulter le manuel dutilisation de lquipement pour les tempratures de service recommandes. M28450A Besoin daide?
Pour obtenir de laide avec ce produit, merci de visiter http://controls.mehvac.com ou dappeler Mitsubishi Electric au numro gratuit 888-990-7546 Lire et conserver ces instructions. 2010 Mitsubishi Electric & Electronics USA, Inc. Suwanee, GA 30024. Brevets en instance. Tous droits rservs. Le logo trois losanges est une marque dpose de Mitsubishi Electric Corporation www.mitsubishipro.com English: see page 1 Espaol: vea la pgina 68 Contenu propos de votre nouveau rgulateur distance Visualisation de la programmation .. 36 Rfrence rapide des commandes .............................. 37 Rfrence rapide de lcran daffichage ....................................... 38 Programmation et fonctionnement Rgler lheure et le jour ................... 39 Slectionner le rglage du ventilateur ................................... 40 Slectionner le mode du systme .. 41 Configurations multizones .............. 42 Mode de schage ............................ 43 Programmes .................................... 44 Drogations au programme ............ 47 Commutation du systme ............... 51 Rgulateur central portatif .............. 52 Capteur dair extrieur .................... 53 Caractristiques supplmentaires .. 54 Annexes Fonctions volues ......................... 58 Remplacement des piles ................. 62 En cas de problme ........................ 65 Informations rglementaires ........... 66 Garantie limite ................................ 67 35 69-2427EFS01 Mode demploi propos du rgulateur distance Le nouveau rgulateur distance est prprogramm et prt tre utilis. Il suffit de rgler le jour et lheure. Vrifier ensuite les rglages ci-dessous et les modifier si ncessaire :
1. 2. 3. 4. Rgler le jour et lheure
(requis pour un fonctionnement correct) ..................................... Voir page 39
......................................... Voir page 40 Slectionner le rglage du ventilateur
................................................... Voir page 41 Slectionner le mode du systme Programmes :
dnergie lorsque lespace est occup (en supposant une arrive 8 h et un dpart 22 h).......................................... Voir pages 44-45 Prrgls aux niveaux dconomie COMMANDE DE TEMPRATURE PAR SIMPLE PRESSION : Il est possible de droger au programme tout moment et de rgler manuellement la temprature (voir pages 47-50). 69-2427EFS01 36 English: see page 1 Espaol: vea la pgina 68 Rfrence rapide des commandes Affichage numrique (voir p. 38) Boutons de temprature Appuyer sur ces boutons pour rgler la temprature Support des piles
(voir page 62) Boutons de fonction Appuyer pour slectionner la fonction affiche juste au-dessus de chaque bouton. (Les fonctions changent en fonction de la tche.) M28451A Bouton de maintien (Hold) Appuyer pour droger la commande de temprature programme (voir page 50). 37 69-2427EFS01 Mode demploi Rfrence rapide de lcran daffichage Dmarrage optimal
(voir page 57) Temprature intrieure courante Priode du programme en cours occup/inoccup/rveil/
dpart/retour/sommeil
(voir pages 44-45) Rgler lheure/le jour/le programme
(voir pages 39 and 46) Avertissements de piles faibles (voir page 62) Heure courante
(voir page 39) Recovery Indoor ReplaceBattery Heat Setting Rglage de la temprature
(voir pages 4650) occupied1 Set Clock/Day Schedule Fan Auto AM System Heat Verrouill
(voir page 57) Plus (More)
(voir pages 5457) Locked More M32209 Rglage du ventilateur Auto/Marche/Slectionnable
(voir page 40) Mode du systme Refroidissement/Chauffage/Schage/
Auto/Arrt (voir page 41) Remarque : Les options peuvent varier en fonction de lquipement 69-2427EFS01 38 English: see page 1 Espaol: vea la pgina 68 Rgler lheure et le jour Appuyer sur SET CLOCK/DAY/SCHEDULE (Rgler heure/jour/
calendrier), puis rgler lheure. Set Clock/Day Schedule Fan Auto System Heat More M32218 Appuyer sur SET DAY (Rgler le jour), puis slectionner le jour en cours. Set Day Set Day Mo Done Set Schedule M32211 39 1. Appuyer sur SET CLOCK/DAY/SCHEDULE puis appuyer sur s ou t pour rgler lheure. 2. Appuyer sur SET DAY puis appuyer sur s ou t pour choisir le jour de la semaine 3. Appuyer sur DONE (Termin) pour enregistrer les rglages. Remarque : Si loption SET CLOCK/DAY/
SCHEDULE nest pas affiche, appuyer sur DONE (Termin) ou CANCEL (Annuler). Remarque : Si les mots Set Clock
(Rgler lheure) clignotent lcran, le rgulateur distance respectera les rglages prvus pour la priode occupied1 (occup1) (ou Wake
[Rveil]) jusqu ce que lheure et le jour soient rgls. 69-2427EFS01 Mode demploi Slectionner le rglage du ventilateur Set Clock/Day Schedule Fan Auto System Heat Fan System Lo Hi Heat Set Clock/Day Schedule More M32212 More M32213 Remarque : Les options de vitesses de ventilateur slectionnables peuvent varier en fonction de lquipement. Appuyer sur FAN (Ventilateur) pour slectionner la vitesse automatique ou slectionnable du ventilateur. En mode automatique, lquipement dtermine la vitesse optimale du ventilateur en fonction de la temprature rgle. Lorsque le systme est sur Arrt, appuyer sur FAN pour faire circuler lair. Le ventilateur tourne la vitesse slectionne par lutilisateur. 69-2427EFS01 40 English: see page 1 Espaol: vea la pgina 68 Slectionner le mode du systme Fan Auto Fan Auto Fan Auto Fan Auto Set Clock/Day Schedule Set Clock/Day Schedule Set Clock/Day Schedule Set Clock/Day Schedule System Cool System Heat System Drying System Auto More M32214 More M32215 More M32300 More Remarque : Les options peuvent varier en fonction de lquipement. M32301 Appuyer sur SYSTEM pour slectionner :
Cool (Refroidissement) : Le rgulateur distance ne commande quen mode de refroidissement. Heat (Chauffage) : Le rgulateur distance ne commande quen mode de chauffage. Drying (Schage) : Le rgulateur distance commande lunit intrieure de retirer lhumidit de lair. Ceci peut entraner des tempratures infrieures au rglage. Auto(matique) : RC passe automatique-
ment du systme de chauffage au systme de refroidissement en fonction de la tem-
prature lintrieur. Off (Arrt) : Lunit intrieure est arrte. 41 69-2427EFS01 Mode demploi Configurations multizones Indoor Wait Heat Setting occupied1 Set Clock/Day Schedule Fan Auto AM System Heat More M28946 Dans les configurations multizones, chaque zone est gnralement rgle sur le mme mode (refroidissement, chauffage ou schage). Si les zones sont rgles sur diffrents modes, lunit intrieure appelant la premire le chauffage ou le refroidissement a la priorit. Les autres zones se mettent en mode de veille et Wait (Attente) saffiche sur lcran. 69-2427EFS01 42 English: see page 1 Espaol: vea la pgina 68 Mode de schage (si configur) Set Clock/Day Schedule Fan Auto System Drying More M28947 Le mode de schage permet de retirer lhumidit de lair et fonctionne diffremment en fonction du type dquipement install. Le rglage de temprature peut ou non tre affich. Lunit intrieure dtermine le rglage de temprature du mode de schage. Le rglage est soit :
le rglage de temprature de refroidissement, soit 2 C (3 F) infrieur la temprature ambiante. 43 69-2427EFS01 Mode demploi Rglages par dfaut du programme commercial Ce rgulateur distance est prrgl pour utiliser les rglages du programme dconomie dnergie. Il est recommand dutiliser ces rglages, car ils peuvent rduire les cots de chauffage et de refroidissement. (Voir page 46 pour rgler lheure et la temprature de chaque priode.) occupied1/
occup1
(08:00) unoccupied1/
inoccup1
(22:00) occupied 2/
occup 2 unoccupied 2/
inoccup 2 Heat/Chauffage
(Lun.-Ven.) Cool/Refroidissement
(Lun.-Ven.) Heat/Chauffage
(Sam.-Dim.) Cool/Refroidissement
(Sam.-Dim.) 70 55
--
--
75 85
--
--
70 55
--
--
75 85
--
--
Les priodes occupied 2 (occup 2) et unoccupied 2 (inoccup 2) peuvent tre programmes selon le besoin, en fonction de la configuration installe. 69-2427EFS01 44 English: see page 1 Espaol: vea la pgina 68 Rglages par dfaut du programme rsidentiel Ce rgulateur distance est prrgl pour utiliser les rglages du programme dconomie dnergie commercial. Pour une utilisation domicile, changer le programme en fonction de lemploi du temps. (Voir page 46 pour rgler lheure et la temprature de chaque priode.) Heat/Chauffage Cool/Refroidissement Heat/Chauffage Cool/Refroidissement
(Lun.-Ven.)
(Lun.-Ven.)
(Sam.-Dim.)
(Sam.-Dim.) Wake/Rveil
(08:00) Leave/Dpart
(22:00) Return/Retour Sleep/Coucher 70 55
--
--
75 85
--
--
(ou annuler la priode) 70 55
--
--
(ou annuler la priode) 75 85
--
--
Les priodes de dpart, retour et sommeil peuvent tre annules. 45 69-2427EFS01 Mode demploi Pour rgler le programme Set Clock/Day Schedule Fan Auto System Heat Set Day Done More M32218 Set Schedule M32219 Remarque : Une priode peut tre annule en utilisant le bouton CANCEL PERIOD (Annuler la priode). Si configur pour cela, le systme peut tre compltement dsactiv durant la priode en utilisant le bouton POWER OFF PERIOD (Priode dsactive). 1. Appuyer sur SET CLOCK/DAY/SCHEDULE, puis sur SET SCHEDULE. 2. Appuyer sur s ou t pour rgler lheure occupied1/Wake des jours de la semaine
(Lun-Ven), puis appuyer ensuite sur NEXT. 3. Appuyer sur s ou t pour rgler la temprature du chauffage pour cette priode, puis appuyer sur NEXT. 4. Appuyer sur s ou t pour rgler la temprature de refroidissement pour cette priode, puis appuyer sur NEXT. 5. Rgler la temprature et lheure de la priode suivante (unoccupied1/Leave). Rpter les tapes 4 et 5 pour chaque priode des jours de la semaine. 6. Appuyer sur NEXT pour rgler les priodes de la fin de semaine (Sam-Dim), puis appuyer sur DONE pour enregistrer le programme et quitter. 69-2427EFS01 46 English: see page 1 Espaol: vea la pgina 68 Drogation au programme (commercial uniquement) Appuyer pour ajuster provisoirement la temprature. Indoor Indoor75 Cancel Cancel Fan Auto Fan Auto Hold PM Hold Until 6:00 System System Auto Heat PM Heat Cool Setting Setting 75 More More M32221 Appuyer pour revenir au programme. M28461 Si une personne est prsente durant une priode inoccupe, appuyer sur HOLD (Maintien) pour activer provisoire-
ment la temprature de priode occu-
pe. Chaque pression supplmentaire sur HOLD en augmente la dure dune heure jusqu une limite rgle par linstallateur. La minuterie expire automatiquement ou le programme peut tre manuelle-
ment repris en appuyant sur CANCEL. Remarque : Maintien permanent non disponible sur la configuration commerciale. 47 69-2427EFS01 Mode demploi Drogation pour les vacances (commercial uniquement) Done Hold Until Days Hold Until Days Done Reset Si le btiment sera inoccup pendant plus dune journe, la fonction de drogation pour les vacances peut tre util-
ise pour maintenir une temprature de zone inoccupe. Appuyer sur MORE jusqu ce que lcran Hold Until
(Maintenir jusqu) saffiche. Appuyer sur s ou t pour rgler le nombre de jours, puis appuyer sur NEXT. Appuyer sur s ou t pour rgler la temprature de chauffage ou de refroidissement, puis appuyer sur DONE. Le rglage de la temprature de refroidissement ne peut tre quaugment et celui de la temprature de chauffage que rduit par rapport au programme inoccup. Pour annuler la drogation pour vacances de lcran daccueil, appuyer sur CANCEL. M28948 Cool Setting Select Heat/Cool M28950 69-2427EFS01 48 Maintien provisoire (rsidentiel uniquement) Appuyer pour ajuster provisoirement la temprature English: see page 1 Espaol: vea la pgina 68 Indoor Hold Until PM Cancel Fan Auto System Auto Cool Setting More M32221 La temprature est maintenue jusqu lheure indique Appuyer pour revenir au programme Appuyer sur s ou t pour ajuster immdiatement la temprature. Cette fonction permet de droger provisoirement la temprature de consigne de la priode en cours. La nouvelle temprature de consigne restera en vigueur jusquau dbut de la prochaine priode seulement (voir page 45). Pour annuler cette drogation, il suffit dappuyer nimporte quel moment sur CANCEL. 49 69-2427EFS01 Mode demploi Maintien permanent (rsidentiel uniquement) Appuyer ici pour modifier la temprature en permanence. Hold Hold Heat Setting Cool Setting 75 Indoor Indoor75 Cancel Cancel Fan Fan Auto Auto PM PM 6:00 System System Auto Heat More More M32222 M28461 La temprature sera maintenue jusqu ce que le bouton CANCEL soit press. Appuyer pour revenir au programme 69-2427EFS01 50 Appuyer sur HOLD pour ajuster la temp-
rature de faon permanente. Cette fonction permet de droger la temprature de consigne pour toutes les priodes. La fonction de maintien HOLD met le programme hors service et permet dajuster la temprature manuellement, au besoin. Le systme maintient la temprature rgle jusqu ce quelle soit manuellement modifie ou que CANCEL soit press pour revenir au programme.
This product uses the FCC Data API but is not endorsed or certified by the FCC