Operating Manual FocusPRO TH6320R Wireless Thermostat Termstato inalmbrico Thermostat Sans Fil Quick Reference Card Grasp and pull to see basic operating instructions at a glance. Battery Holder Press down and pull to remove batteries. Batteries should be replaced once a year
(see page 16). CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50F (10C). Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 Read and save these instructions U.S. Registered Trademark. Patents pending. Copyright 2008 Honeywell International Inc. All rights reserved. Contents Espaol: vea la pgina 20 Franais : voir la page 40 About your new thermostat Programming at a glance............2 Quick reference to controls ........3 Quick reference to display ..........4 Programming & Operation Set time and day ........................5 Fan settings (auto/on) ................6 System settings (heat/cool)..........7 Program schedules ....................8 Program schedule overrides ....10 Auto-changeover (heat/cool) ....12 Remote control ..........................13 Display outdoor climate ............14 Find lost remote control............14 Special features ........................15 Appendices Battery replacement..................16 In case of difficulty ....................18 Limited warranty........................19 Regulatory information..............60 11 About your new thermostat Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed:
1 Set time and day (required for proper operation)...............See page 5 2 Select fan setting (Auto/On)....................................................See page 6 3 Select system setting (Heat/Cool) .........................................See page 7 4 Program schedules: Preset to energy-saving levels while youre at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to bed at 10 pm).........................................................See pages 8-9 ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 10-11). 2 Quick reference to controls Digital display (see page 4) Battery holder (see page 16) Temperature buttons Press to adjust temperature settings (see page 10-11) Hold button Press to override programmed temperature control (see page 11) Function buttons Press to select the function displayed just above each button.
(Functions change depending on the task.) 3 Quick reference to display screen Current inside temperature Low battery warnings
(see pages 16-17) Current time/day
(see page 5) Recovery
(see page 15) Current program period Wake/Leave/Return/Sleep
(see pages 8-9) Set Clock/Day/Schedule
(see pages 5 & 9) Fan setting Auto/On (see page 6) Indoor Recovery Replace Battery Heat 75 6:30 AM Setting 75 Aux Heat On Fan Auto System Heat More Wake Set Clock/Day Schedule Temperature setting
(see pages 9-11) Auxiliary heat
(Only for heat pumps with auxiliary heat) System status Heat On/Cool On
(If flashing, see p. 15) System setting Heat/Cool/Auto/Off/Em Heat (see page 7) More Press to view outdoor climate (if outdoor sensor is installed), or to find a misplaced remote control if installed (see page 14) 4 Set the time and day Press SET CLOCK/DAY/SCHEDULE, then adjust time 4:30 PM Set Clock/Day Schedule Fan Auto System Heat More Press SET DAY, then select current day Wed Set Day Set Schedule Done 1 Press SET CLOCK/DAY/SCHEDULE, then press or to set clock. 2 Press SET DAY, then press or to select the day of week. 3 Press DONE to save. Note: If the SET CLOCK/DAY/SCHEDULE option is not displayed, press DONE or CANCEL. Note: If the display flashes Set Clock, the thermostat will follow your settings for the weekday Wake time period until you reset the time and day. 5 Select the fan setting Set Clock/Day Schedule Set Clock/Day Schedule Fan Auto System Heat More Fan On System Heat More Note: Options may vary depending on your heating/
cooling equipment. Press FAN to select Auto or On. In Auto mode (the most commonly used setting), the fan runs only when the heating or cooling system is on. If set to On, the fan runs continuously. 6 Select the system setting Set Clock/Day Schedule Fan Auto System Heat More Set Clock/Day Schedule Fan Auto System More Cool Note: Options may vary depending on your heating/
cooling equipment. Press SYSTEM to select:
Heat: Thermostat controls only the heating system.
Cool: Thermostat controls only the cooling system.
Off: All systems are off.
Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature.
Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat. Compressor is locked out. 7 EnergyStar settings for maximum cost savings This thermostat is pre-set to use EnergyStar program settings. We recom-
mend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.) Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) Wake
(6:00 am) Leave
(8:00 am) Return
(6:00 pm) Sleep
(10:00 pm) 70 62 70 62 78 85 78 82 8 70 62 70 62 78 85 78 82
[Or cancel period]
[Or cancel period]
[Or cancel period]
[Or cancel period]
To adjust program schedules Set Clock/Day Schedule Done Fan Auto System Heat More Set Day Set Schedule Set Schedule 6:00 AM 70 Heat Setting Mon Tue Wed Thu Fri Wake Done Cancel Period Next 1 Press SET CLOCK/DAY/SCHEDULE, then SET SCHEDULE. 2 Press or to set your weekday Wake time (Mon-Fri), then press NEXT. to set the temperature 3 Press or for this time period, then press NEXT. 4 Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period. 5 Press NEXT to set weekend time periods (Sat-Sun), then press DONE to save & exit. Note: Make sure the thermostat is set to the system you want to program (Heat or Cool). 9 Program schedule override (temporary) Press to temporarily adjust temperature Indoor 75 6:00 PM Hold Until Heat Setting 75 Cancel Fan Auto System Heat More Press to resume program schedule Temperature will be maintained until time shown 10 or to immediately Press adjust the temperature. This will temporarily override the temper-
ature setting for the current time period. The new temperature will be maintained only until the next programmed time period begins
(see page 8). To cancel the temporary setting at any time, press CANCEL. Program schedule override (permanent) Press to permanently adjust temperature Indoor 75 6:00 PM Hold Heat Setting 75 Cancel Fan Auto System Heat More Press to resume program schedule Press HOLD to permanently adjust the temperature. This will over-
ride the temperature settings for all time periods. The Hold feature turns off the program schedule and allows you to adjust the thermostat manually, as needed. Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press CANCEL to resume the pro-
grammed schedule. 11 Auto Changeover (heat/cool) Set Clock/Day Schedule Fan Auto System More Auto Press until screen displays Auto Note: The Auto system setting may not appear, depending on how your thermostat was installed. Auto Changeover is a feature used in climates where both air conditioning and heating are often used on the same day. When the system is set to Auto, the ther-
mostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 3 degrees apart. The thermostat will auto-
matically adjust settings to maintain this 3-degree separation. 12 Remote control Temperature is measured at location of remote control 72 Remote has Control at Thermostat Cancel Fan Auto 75 Reading at Remote More The optional remote control can act as a mobile thermostat, to maintain a comfortable temperature as you move from room to room. When the system is responding to temperatures measured at the Remote, the thermostat will display Remote has Control. Press CANCEL to restore temperature control to the thermostat (the system will only respond to temperatures measured at the thermostat). Note: The thermostat may take up to 15 seconds to respond to commands entered at the remote control. See Remote Control Operating Manual for more information. 13 Additional features Set Clock/Day Schedule Fan Auto System Heat More Press to display more options Outdoor temperature Outdoor humidity Outdoor85 Outdoor Humidity 50
FindRemote Done To display outdoor climate If you have an outdoor air sensor, press MORE to display the current outdoor tem-
perature and humidity. Press DONE to exit. To find a lost remote control If you misplace a remote control, press MORE, then FIND REMOTE. The remote will beep for two minutes to help you locate it. Press anywhere on the display screen to stop the beeping. Press to find a lost remote control 14 Special features Built-in compressor protection: This feature helps prevent damage to the compressor in your air conditioning or heat pump system. Damage can occur if the compressor is re-started too soon after shutdown. This feature forces the compressor to wait for a few minutes before restarting. During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). Adaptive Intelligent Recovery: This feature eliminates guesswork when setting your schedule. It allows the thermostat to learn how long your fur-
nace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. Note: When Adaptive Intelligent Recovery is in effect, the thermostat will display Recovery. 15 Battery replacement (thermostat) Press and pull to remove Insert fresh AA alkaline batteries, then reinstall battery holder Install fresh batteries when the REPLACE BATTERY warning begins flashing. The warn-
ing flashes about two months before the batteries are depleted. Remove the battery holder and install 2 fresh AA alkaline batteries. After batteries are installed, the thermo-
stat will automatically restore communi-
cation with the wireless network within a few minutes. Note: If batteries are inserted within t2 minutes, the time and day will not have to be reset. All other settings are retained in memory. 16 Battery replacement (outdoor air sensor) Remove sensor from bracket Replace outdoor sensor batteries when the REPLACE BATTERY OUTDOOR warning begins flashing on the thermostat. The warning flashes about two months before the bat-
teries are depleted. Remove the sensor from the bracket, remove the cover and install 2 fresh AA lithium batteries. After batteries are installed, the sensor will automatically restore communication with the wireless network within a few minutes. 17 Remove cover and install 2 fresh AA lithium batteries In case of difficulty Heating or cooling system does not respond
Check circuit breaker and reset if necessary.
Make sure power switch at heating & cooling system is on.
Make sure furnace door is closed securely.
Wait 5 minutes for the system to respond. Screen displays No Signal Thermostat has lost radio contact with the wireless network (usually because of a power outage). To restore power:
Check circuit breaker and reset if necessary.
Make sure power switch at heating & cooling system is on.
Make sure furnace door is closed securely. After power is restored, the thermostat will automatically restore wireless communication within a few minutes. 18 Up to 5-year limited warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defec-
tive or malfunctions, Honeywell shall repair or replace it (at Honeywell's option). If the product is defective,
(i) return it, with a bill of sale or other dated proof of pur-
chase, to the place from which you purchased it; or
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a con-
sumer. Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUEN-
TIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, 19 FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of inci-
dental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HON-
EYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE, IS HEREBY LIMITED TO THE THREE-YEAR DURA-
TION OF THIS WARRANTY. Some states do not allow limita-
tions on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limite, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9. When the product is registered on-line at www.warranty.Honeywell.com, the standard manufacture coverage stated above extends to a period of (5) years. Tarjeta de referencia Sujete la tarjeta y jale de ella para ver rpida-
mente las instrucciones bsicas de funcionamiento. Soporte de las bateras Presione y jale para retirar las bateras. Las bateras deben reemplazarse una vez al ao.
(vea la pg. 16). PRECAUCIN: RIESGO DE DAO AL EQUIPO. Para evitar posibles daos al compre-
sor, no haga funcionar el sistema de refrigeracin cuando la temperatura exterior sea inferior a 50 F (10 C). Necesita ayuda?
Consulte sobre este producto en http://yourhome.honeywell.com o llamando sin cargo a atencin al cliente de Honeywell 1-800-468-1502 Lea y guarde estas instrucciones Marca registrada de los EE. UU. Patentes en trmite. Copyright 2008 Honeywell International Inc. Todos los derechos reservados. ndice Espaol: vea la pgina 20 Franais : voir la page 40 Acerca de su termostato nuevo Programacin rpida ................22 Referencia de los controles ......23 Referencia de la pantalla ..........24 Programacin y funcionamiento Configuracin de la hora/da ....25 Configuracin del ventilador ....26 Configuracin del sistema ........27 Cronogramas del programa......28 Anulacin del cronograma del programa ............................30 Funcin Auto Changeover
(Heat/Cool) ................................32 Control remoto ..........................33 Visualizacin de la temperatura exterior..................34 Bsqueda del control remoto extraviado ..................................34 Funciones especiales................35 Apndices Reemplazo de las bateras ......36 En caso de inconvenientes ......38 Garanta limitada ......................39 Informacin reguladora ............60 21 Acerca de su termostato nuevo Su termostato nuevo est preprogramado y listo para funcionar. Todo lo que tiene que hacer es configurar la hora y el da. Luego, revise las sigu-
ientes configuraciones y, si es necesario, cmbielas:
1 Configuracin de la hora/da (necesaria).........................Vea la pg. 25 2 Seleccin de la configuracin del ventilador (Auto/On) ....Vea la pg. 26 3 Seleccin de la configuracin del sistema (Heat/Cool)...Vea la pg. 27 4 Cronogramas del programa: predeterminados en niveles de ahorro de energa mientras est en el trabajo o duerme............................................................Vea las pgs. 28-29 CONTROL DE TEMP. AL TACTO: puede anular la configuracin del cronograma en cualquier momento y ajustar manualmente la temperatura (vea las pgs. 30 a 31). 22 Referencia rpida de los controles Pantalla digital (vea la pg. 24) Soporte de las bateras
(vea la pg. 36) Botones de la temperatura Presione para ajustar las configuraciones de temperatura
(vea las pgs. 30 a 31) Botn Hold Presione para anular el control de temperatura programada (vea la pg. 31) Botones de funciones Presione para elegir la funcin que se muestra encima de cada botn. 23 Referencia rpida de la pantalla Temperatura interior actual Avisos de batera baja
(vea pgs. 36-37) Hora y da actuales
(vea pg. 25) Recovery
(vea pg. 35) Perodo del programa Wake/Leave/Return/Sleep
(vea pg. 28-29) Set Clock/Day/Schedule
(vea pgs. 25 & 29) Config. del ventilador Auto/On (svea pg. 26) Indoor Recovery Replace Battery Heat 75 6:30 AM Setting 75 Aux Heat On Fan Auto System Heat More Wake Set Clock/Day Schedule Config. de la temp.
(vea p. 29-31) Calefaccin auxiliar
(solo para bombas de calor con calefaccin auxiliar) Estado del sistema Heat On/Cool On
(si destella, vea p. 25) Config. del sistema Heat/Cool/Auto/Off/Em Heat (vea pg. 27) 24 More Presione para ver la temperatura exterior (si se instal un sensor exterior) o para buscar un control remoto extraviado si est instalado
(vea pg. 24) Configuracin de la hora y el da Presione SET CLOCK/DAY/SCHEDULE y luego ajuste la hora 1 Presione SET CLOCK/DAY/SCHEDULE y 4:30 PM luego presione configurar la hora. o para Set Clock/Day Schedule Fan Auto System Heat More Presione SET DAY y luego seleccione el da Wed Set Day Set Schedule Done 2 Presione SET DAY y luego pre-
para seleccionar sione el da de la semana. o 3 Presione DONE para guardar. Nota: si no se muestra la opcin SET CLOCK/DAY/SCHEDULE, presione DONE o CANCEL. Nota: si en la pantalla aparece el mensaje Set Clock, el termostato seguir sus configuraciones para el perodo Wake de los das de sem-
ana, hasta que vuelva a configurar la hora y el da. 25 Seleccin de la configuracin del ventilador Set Clock/Day Schedule Set Clock/Day Schedule Fan Auto System Heat More Fan On System Heat More Presione FAN para seleccionar Auto u On. En el modo Auto, la configuracin ms comnmente utilizada, el ventilador fun-
ciona solamente cuando est encendido el sistema de calefaccin o refrigeracin. Si se configura en On, el ventilador funciona continuamente. Nota: las opciones pueden variar segn el equipo de calefaccin/
refrigeracin. 26 Seleccin de la configuracin del sistema Set Clock/Day Schedule Fan Auto System Heat More Set Clock/Day Schedule Fan Auto System More Cool Nota: las opciones pueden variar segn el equipo de calefaccin/
refrigeracin. Nota: para evitar posibles daos al compresor, no haga funcionar el sistema de refrigeracin cuando la temperatura exterior sea inferior a 50F (10C). Presione SYSTEM para seleccionar:
Heat: el termostato controla sola-
mente el sistema de calefaccin.
Cool: el termostato controla sola-
mente el sistema de refrigeracin.
Off: los sistemas de calefaccin y refrigeracin estn apagados.
Auto: el termostato elige cundo calentar o refrigerar, segn la temperatura interior.
Em Heat (solamente para bombas de calor con calefaccin auxiliar): el termostato controla la calefaccin auxiliar y de emergencia. El compre-
sor se bloquea. 27 Configuraciones de EnergyStar para mayores ahorros en los costos Este termostato est configurado previamente para utilizar las configura-
ciones del programa EnergyStar . Recomendamos estas configuraciones debido a que reducen los gastos de calefaccin y refrigeracin hasta en un 33%. (Vea la pg. siguiente para ajustar las horas y las temperaturas de cada perodo). Heat (Lun-Vier) Cool (Lun-Vier) Heat (Sb-Dom) Cool (Sb-Dom) Wake
(6:00 am) Leave
(8:00 am) Return
(6:00 pm) Sleep
(10:00 pm) 70 62 70 62 70 62 70 62 78 85 78 82 78 85 78 82 28 Para ajustar los cronogramas del programa Set Clock/Day Schedule Done Fan Auto System Heat More Set Day Set Schedule Set Schedule 6:00 AM 70 Heat Setting Mon Tue Wed Thu Fri Wake Done Cancel Period Next Nota: asegrese de que el termostato est configurado en el sistema que desea programar
(Heat o Cool). 1 Presione SET CLOCK/DAY/SCHEDULE y luego SET SCHEDULE. 2 Presione o para configurar la hora Wake (de lunes a viernes) y luego presione NEXT. o para configurar la 3 Presione temperatura para este perodo y luego presione NEXT. 4 Configure la hora y la temperatura para el prximo perodo (Leave). Repita los pasos 2 y 3 para cada da de la semana. 5 Presione NEXT para configurar los perodos para el fin de semana (de sbado a domingo) y luego presione DONE para guardar y salir. 29 Anulacin del cronograma del programa (temporal) Presione para ajustar temporalmente la temp. Indoor 75 6:00 PM Hold Until Heat Setting 75 Cancel Fan Auto System Heat More La temperatura se mantendr hasta la hora que se muestra Presione para volver al cronograma del programa 30 o para ajustar la Presione temperatura inmediatamente. Esto anular temporalmente la configuracin de la temperatura para el perodo actual. La nueva temperatura se mantendr solamente hasta que comience el prximo perodo programado (vea la pg. 28). Para cancelar esta configuracin en cualquier momento, presione CANCEL. Anulacin del cronograma del programa (permanente) Presione para ajustar permanentemente la temp. Indoor 75 6:00 PM Hold Heat Setting 75 Cancel Fan Auto System Heat More Presione para volver al cronograma del programa 31 Presione HOLD para ajustar perma-
nentemente la temperatura. Esto anular las configuraciones de temperatura para todos los perodos. La funcin Hold apaga el crono-
grama del programa y le permite ajustar el termostato manualmente, segn sea necesario. La temperatura que usted config-
ure se mantendr las 24 horas del da, hasta que la cambie manual-
mente o presione CANCEL para volver al cronograma programado. Funcin Auto Changeover (Heat/Cool) Set Clock/Day Schedule Fan Auto System More Auto Presione hasta que la pantalla muestre Auto Nota: quizs la configuracin Auto del sistema no aparezca, segn cmo haya sido instala-
do el termostato. Auto Changeover es una funcin utiliza-
da en climas donde, a menudo, se usan el acondicionador de aire y la calefac-
cin en el mismo da. Cuando el sistema est configurado en Auto, el termostato elige automticamente cundo calentar o refrigerar, segn la temperatura interior. Las configuraciones de calor y fro deben tener, al menos, 3 grados de diferencia. El termostato ajustar automticamente las configuraciones para mantener esta diferencia de 3 grados. 32 Control remoto La temperatura se mide en la ubicacin del control remoto 72 Remote has Control at Thermostat Cancel Fan Auto 75 Reading at Remote More El control remoto opcional puede funcionar como termostato mvil para mantener una temperatura agradable mientras pasa de una habitacin a otra. Cuando el sistema responda a las tem-
peraturas medidas en el control remoto, el termostato mostrar el mensaje Remote has Control. Presione CANCEL para restablecer el con-
trol de temperatura en el termostato (el sistema solo responder a las tempera -
turas medidas en el termostato). Nota: el termostato puede demorar hasta 15 segundos en responder a los comandos ingresados en el control remoto. Consulte el Manual de funcionamiento del control remoto para obtener ms informacin. 33 Funciones adicionales Set Clock/Day Schedule Fan Auto System Heat More Presione para mostrar ms opciones Temperatura exterior Humedad exterior Outdoor85 Outdoor Humidity 50
FindRemote Done Presione para buscar un control remoto extraviado Visualizar la temperatura exterior Si tiene un sensor de aire exterior, pre-
sione MORE para visualizar la temperatura y la humedad exteriores actuales. Presione DONE para salir. Buscar un control remoto extraviado Si extravi un control remoto, presione MORE y luego FIND REMOTE. El control remoto emitir un pitido durante dos minutos para ayudarlo a ubicarlo. Presione en cualquier lugar de la pantalla de control remoto para detener el pitido. 34 Caractersticas especiales Proteccin del compresor incorporada: esta funcin ayuda a evitar daos al compresor en su acondicionador de aire o en su sistema de bomba de calor. El compresor puede daarse si se vuelve a iniciar inmediatamente despus de ser apagado. Esta caracterstica hace que el compresor demore unos minutos antes de volver a iniciarse. Durante el tiempo de espera, la pantalla mostrar el mensaje Cool On (o Heat On si tiene una bomba de calor). Adaptive Intelligent Recovery: esta funcin elimina la necesidad de con-
jeturas a la hora de configurar un cronograma. Permite que el termostato sepa cunto demora su sistema de calefaccin y su aire acondicionado para alcanzar las configuraciones de temperatura programadas, de manera que se alcance esa temperatura a la hora que usted configur. Nota: cuando la funcin Adaptive Intelligent Recovery est activada, el termostato mostrar Recovery. 35 Reemplazo de las bateras (termostato) Presione y jale para retirar Instale las bateras alcalinas AA nuevas y vuelva a colocar el soporte de las bateras Instale las bateras nuevas cuando el aviso REPLACE BATTERY comience a destellar. El aviso destellar durante, aproximada-
mente, dos meses antes de que se agoten las bateras. Retire el soporte de las bateras e instale 2 bateras alcalinas AA nuevas. Despus de instalar las bateras, el ter-
mostato restablecer automticamente la comunicacin con la red inalmbrica en pocos minutos. Nota: si coloca las bateras a los dos minutos, no tendr que volver a configurar la hora y el da. Las dems configuraciones permanecen en la memoria. 36 Reemplazo de las bateras (sensor de aire exterior) Retire el sensor del soporte Reemplace las bateras del sensor exteri-
or cuando el aviso REPLACE BATTERY OUTDOOR comience a destellar en el termostato. El aviso destellar durante, aproximada-
mente, dos meses antes de que se agoten las bateras. Retire el sensor del soporte, quite la tapa e instale 2 bateras AA de litio nuevas. Despus de instalar las bateras, el sensor restablecer automticamente la comuni-
cacin con la red inalmbrica en pocos minutos. 37 Quite la tapa e instale 2 bateras AA de litio nuevas En caso de inconvenientes El sistema de calefaccin o refrigeracin no responde
Controle el interruptor de circuito y, si es necesario, reincielo.
Asegrese de que el interruptor de energa del sistema de calefaccin y efrigeracin est encendido.
Asegrese de que la puerta del sistema de calefaccin est bien cerrada.
Espere 5 minutos para que responda el sistema. La pantalla muestra No signal El termostato perdi contacto con la red inalmbrica (generalmente, debido a un corte de energa). Para restaurar la energa:
Controle el interruptor de circuito y, si es necesario, reincielo.
Asegrese de que el interruptor de energa del sistema de calefaccin y refrigeracin est encendido.
Asegrese de que la puerta del sistema de calefaccin est bien cerrada. Despus de restaurar la energa, el termostato restablecer automtica-
mente la comunicacin inalmbrica en pocos minutos. 38 Garanta limitada por hasta 5 aos Honeywell garantiza, por el trmino de tres (3) aos a partir de la fecha de compra por parte del consumidor, que este producto, sin incluir las bateras, no presentar defectos en los materiales ni en lo referente a la mano de obra, en condi-
ciones normales de uso y de servicio. Si en algn momento durante el perodo de vigencia de la garanta se determina que el producto es defectuoso o que funciona mal, Honeywell lo reparar o lo reemplazar (a eleccin de Honeywell). Si el producto presenta defectos,
(i) devulvalo, con la factura de venta o cualquier otro com-
probante de compra, al lugar donde lo compr o
(ii) llame al Servicio al cliente de Honeywell al 1-800-468-
1502. El Servicio al cliente decidir si el producto debe ser devuelto a la siguiente direccin: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, o si se le puede enviar un producto de reemplazo. Esta garanta no cubre los gastos de extraccin ni de rein-
stalacin. Esta garanta no se aplicar si Honeywell demues-
tra que el defecto o el mal funcionamiento fueron causados por daos que se produjeron mientras el producto estaba en posesin de un consumidor. La nica responsabilidad de Honeywell ser la de reparar o reemplazar el producto dentro de los trminos mencionados anteriormente. HONEYWELL NO SER RESPONSABLE DE LA PRDIDA NI DAO DE NINGN TIPO, QUE INCLUYE CUALQUIER DAO INCIDENTAL O CONSECUENTE QUE RESULTE, DIRECTA O INDIRECTAMENTE, DE CUALQUIER INCUMPLIMIENTO DE CUALQUIER GARANTA, EXPRESA O IMPLCITA, O DE CUALQUIER OTRA FALLA DE ESTE PRO-
DUCTO. Algunos estados no permiten la exclusin ni la lim-
itacin de los daos incidentales o consecuentes, por lo que es posible que esta limitacin no se aplique en su caso. ESTA GARANTA ES LA NICA GARANTA EXPRESA QUE HONEYWELL REALIZA SOBRE ESTE PRODUCTO. LA DURACIN DE CUALQUIERA DE LAS GARANTAS IMPLCITAS, INCLUIDAS LAS GARANTAS DE APTITUD E IDONEIDAD PARA UN FIN DETERMINADO, QUEDA, POR EL PRESENTE, LIMITADA A LA DURACIN DE TRES AOS DE ESTA GARANTA. Algunos estados no permiten limitaciones en cuanto a la duracin de una garanta implcita, por lo que es posible que la limitacin anterior no se aplique en su caso. Esta garanta le otorga derechos legales especficos y es posible que usted goce de otros derechos que varan segn el estado. Si tiene preguntas sobre esta garanta, escriba a Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 o llame al 1-800-468-1502. En Canad, escriba a Retail Products ON15-02H, Honeywell Limited/Honeywell Limite, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9. Si el producto est registrado en lnea en www.warranty.Honeywell.com, la cobertura de fabricacin estndar arriba mencionada se prolongar por un perodo de cinco (5) aos. 39 Aide-mmoire Tirer sur la carte pour voir les instructions de base en un coup dil. Porte-piles Appuyer vers le bas et tirer pour retirer les piles. Les piles devraient tre rem-
places une fois par anne (voir la page 56). MISE EN GARDE : RISQUE DE DOMMAGE MATRIEL. Pour viter dendommager le compresseur, ne pas faire fonctionner le systme de refroidissement lorsque la temprature extrieure est infrieure 10 C (50 F). Vous faut-il de laide ?
Pour obtenir de lassistance concernant ce produit, visitez http://yourhome.honeywell.com ou appelez gratuitement lassistance client dHoneywell au 1-800-468-1502 Lisez et sauvez ces instructions Marque de commence enregistre aux tats-Unis. Brevets en instance. Copyright 2008 Honeywell International Inc. Tous droits rservs. Table des matires Espaol: vea la pgina 20 Franais : voir la page 40 Un mot sur votre nouvel appareil Programmation en un coup dil..42 Coup dil sur les commandes 43 Coup dil sur laffichage ........44 Programmation et Fonctionnement Rglage de lheure et du jour ..45 Rglages du ventilateur ............46 Rglages du systme................47 Horaires programms................48 Drogations lhoraire..............50 Commutation chaud-froid automatique ..............................52 Tlcommande ..........................53 Affichage de la temp. extrieure ..54 Retrouver une tlcommande gare ........................................54 Caractristiques spciales........55 Annexes Remplacement des piles ..........56 En cas de difficult....................58 Garantie limite ........................59 Information sur la rglementation ..........................60 41 Un mot sur votre nouvel appareil Votre nouveau thermostat est prprogramm et prt lemploi. Il suffit de rgler lheure et la date. Il faudra ensuite vrifier si les rglages prvus conviennent et les modifier au besoin :
1 Rgler lheure et le jour .........................................................Voir page 45 2 Slectionner le rglage du ventilateur ................................Voir page 46 3 Slectionner le rglage du systme ....................................Voir page 47 4 Horaire programm : Horaire conomiseur prrgl pour les priodes de travail et de sommeil (en supposant que le rveil est 6:00, le dpart de la maison 8:00, le retour 18:00 et le coucher 22:00) ............................................Voir pages 48-49 Rgler la temprature au moyen dune seule touche : Il est possible de droger lhoraire programm en tout temps et de rgler manuellement la temprature (voir pages 50-51). 42 Coup dil sur les commandes Affichage numrique (voir p. 44) Porte-piles (voir p. 56) Boutons de rglage de la temprature Appuyer sur le bouton pour rgler la temprature
(voir p. 50-51) Bouton de Hold Appuyer pour droger au programme (voir la page 51) Boutons de fonction Appuyer pour slectionner la fonction affiche sous chaque bouton. (Le changement de fonction dpend de la tche accomplie.) 43 Coup dil sur laffichage Temprature ambiante Avertissement de piles
(voir p. 56-57) Heure/jour en cours
(voir p. 45) Recovery
(voir p. 55) Priode du programme Wake/Leave/Return/Sleep
(voir p. 48-49) Set Clock/Day/Schedule
(voir p. 45-49) Rglage du ventilateur Auto/On (voir p. 46) Indoor Recovery Replace Battery Heat 75 6:30 AM Setting 75 Aux Heat On Fan Auto System Heat More Wake Set Clock/Day Schedule Point consigne de temp. (voir p. 49-51) Chauffage auxiliaire
(Pour thermopompes avec chauffage auxil-
iaire seulement) tat du systme Heat On/Cool On
(Si laffichage clignote, voir p. 55) Rglage du systme Heat/Cool/Auto/Off/Em Heat (voir p. 47) 44 More Appuyer pour voir la temp. extrieure (si un capteur extrieur est install), ou pour retrouver une tlcommande gare selon le cas
(voir p. 54) Rgler lheure et le jour Appuyer sur SET CLOCK/DAY/SCHEDULE et rgler lheure. 1 Appuyer SET CLOCK/DAY/SCHEDULE, 4:30 PM Set Clock/Day Schedule Fan Auto System Heat More Appuyer sur SET DAY, puis slectionner le jour en cours Wed Set Day Set Schedule Done 45 ou pour rgler puis lheure. 2 Appuyer SET DAY, puis ou pour slectionner le jour de la semaine. 3 Appuyer DONE pour enregistrer. Remarque : Si loption SET CLOCK/DAY/SCHEDULE nest pas affiche, appuyer DONE ou CANCEL. Remarque : Si les mots Set Clock clignotent lcran, le thermostat respectera la consigne prvue pour la priode de rveil (WAKE) jusqu ce que le jour et lheure soient rgls. Slectionner le rglage du ventilateur Set Clock/Day Schedule Set Clock/Day Schedule Fan Auto System Heat More Fan On System Heat More Remarque : Les choix peuvent varier en fonction du systme de chauffage-refroidissement. Appuyer sur la touche du ventilateur (FAN) pour slectionner son mode de fonction-
nement (Auto ou On). En mode de fonctionnement automa-
tique (AUTO), qui est le rglage le plus frquent, le ventilateur fonctionne seule-
ment quand le systme de chauffage ou de refroidissement est en marche. Si cet interrupteur est rgl ON, le ventilateur fonctionne sans interruption. 46 Slectionner le rglage du systme Set Clock/Day Schedule Fan Auto System Heat More Set Clock/Day Schedule Fan Auto System More Cool Remarque : Les choix peuvent varier en fonction du systme de chauffage-refroidissement. Remarque : Pour viter dendommager le compresseur, ne pas faire fonctionner le sys-
tme de refroidissement lorsque la temprature extrieure est infrieure 50 F (10 C). Appuyer SYSTEM pour slectionner :
Heat : Thermostat commande le fonc-
tionnement du systme de chauffage.
Cool : Thermostat commande le fonctionnement du systme de refroidissement.
Off : Tous les systmessont larrt.
Auto : Thermostat passe automatique-
ment du systme de chauffage au sys-
tme de refroidissement en fonction de la temp. lintrieur.
EmHeat : (Thermopompes avec chauffage auxiliaire seulement) : Le thermostat commande le fonction-
nement du chauffage auxiliaire et du chauffage durgence. Le compresseur est mis sous scurit. 47 Rglage EnergyStar pour une conomie dnergie maximale Le thermostat est prrgl aux points de consigne EnergyStar. Nous recom-
mandons de conserver ces points de consigne, puisquils pourraient faire rduire de jusqu 33 % les frais de chauffage-refroidissement. (Voir la page suivante comment rgler lheure et la temprature de consigne pour chacune des priodes.) Heat (Lun-Ven) Cool (Lun-Ven) Heat (Sam-Dim) Cool (Sam-Dim) Wake
(6:00 am) Leave
(8:00 am) Return
(6:00 pm) Sleep
(10:00 pm) 70 62 70 62 70 62 70 62 78 85 78 82 78 85 78 82 48 Rglage de lhoraire Set Clock/Day Schedule Done Fan Auto System Heat More Set Day Set Schedule Set Schedule 6:00 AM 70 Heat Setting Mon Tue Wed Thu Fri Wake Done Cancel Period Next 1 Appuyer SET CLOCK/DAY/SCHEDULE, puis SET SCHEDULE. 2 Appuyer ou pour rgler lheure du rveil des jours de semaine
(Lun-Ven), puis appuyer ensuite NEXT. 3 Appuyer ou pour rgler la temprature de consigne pour cette priode, puis appuyer NEXT. 4 Rgler la temp. et lheure de la priode suivante (Leave, ou dpart). Rpter tapes 2 et 3 pour chaque priode des jours de semaine. 5 Appuyer NEXT pour rgler les priodes Remarque : Sassurer que le thermostat est rgl au systme que lon souhaite faire fonctionner (Heat ou Cool). Sam-Dim, puis appuyer DONE pour enregistrer le programme. 49 Drogation (temporaire) au programme Appuyer pour ajuster temporairement la temp. Indoor 75 6:00 PM Hold Until Heat Setting 75 Cancel Fan Auto System Heat More Appuyer pour reprendre lhoraire programm La temprature sera maintenue jusqu lheure affiche 50 ou pour ajuster Appuyer immdiatement la temprature. Cette fonction permet de droger la temprature de consigne de la priode en cours. La nouvelle temprature de consigne restera en vigueur jusquau dbut de la prochaine priode seulement (voir la page 48). Pour annuler le rglage temporaire, appuyer sur CANCEL. Drogation (permanente) au programme Appuyer pour modifier la temp. en permanence. Indoor 75 6:00 PM Hold Heat Setting 75 Cancel Fan Auto System Heat More Appuyer pour reprendre lhoraire programm 51 Appuyer HOLD pour ajuster la tem-
prature en permanence. Cette fonction permet de droger la temprature de consigne pour toutes les priodes. La fonction de maintien Hold met le programme hors service et permet dajuster le thermostat manuellement, au besoin. Peu importe la temp. rgle, le thermostat maintiendra cette mme temp. toute la journe (24 heures) jusqu ce que le point de consigne soit modifi manuellement ou quon appuie sur la touche CANCEL pour annuler la fonction de maintien et revenir au programme. Commutation chaud-froid automatique Set Clock/Day Schedule Fan Auto System More Auto Appuyer jusqu ce que lcran affiche Auto Remarque : Le rglage Auto peut ne pas apparatre, selon la faon dont le thermostat a t install. Cette caractristique est employe dans les endroits o le chauffage et le refroidissement sont parfois en service le mme jour. Lorsque le systme fonc-
tionne en mode Auto, le thermostat slectionne automatiquement le chauffage ou le refroidissement selon la temprature lintrieur. Il doit absolument y avoir au moins trois degrs dcart entre les points de con-
signe de chauffage et de refroidisse-
ment. Le thermostat ajustera automa-
tiquement les points de consigne pour conserver ces trois degrs dcart. 52 Tlcommande La temprature est mesure lemplacement de la tlcommande 72 Remote has Control at Thermostat Cancel Fan Auto 75 Reading at Remote More Remarque : Il faut parfois jusqu 15 secondes avant que le thermo-
stat ragisse aux commandes entres la tlcommande. Voir le Mode demploi de la tlcom-
mande pour obtenir plus de ren-
seignements. La tlcommande optionnelle peut servir de thermostat mobile afin de maintenir une temprature agrable mesure quon se dplace de pice en pice. Lorsque le systme ragit aux tempra-
tures mesures la tlcommande, le thermostat affiche les mots Remote has Control. Appuyer CANCEL pour que la rgulation de la temprature revienne au thermostat (le systme ragira seulement aux tempra-
tures mesures au thermostat). 53 Caractristiques additionnelles Set Clock/Day Schedule Fan Auto System Heat More Appuyer pour afficher dautres options Temprature extrieure Humidit extrieure Outdoor85 Outdoor Humidity 50
FindRemote Done Pour afficher la temprature extrieure Sil y a un capteur dair extrieur, appuy-
er MORE pour afficher la temprature et lhumidit extrieures. Appuyer DONE pour quitter. Pour retrouver une tlcommande gare Pour retrouver une tlcommande gare, appuyer MORE, puis FIND REMOTE. La tlcom-
mande mettra un son pendant deux min-
utes pour donner lutilisateur le temps de la retrouver. Appuyer nimporte o sur lcran pour interrompre la tonalit. Appuyer pour retrouver une tlcommande gare 54 Caractristiques spciales Protection intgre du compresseur : Cette fonction sert viter dendommager le compresseur qui fait partie du systme de refroidisse-
ment ou de la thermopompe. Le compresseur pourrait en effet tre endom-
mag sil redmarre trop rapidement aprs avoir t mis larrt. Cette fonction oblige le compresseur attendre 5 minutes avant de redmarrer. Pendant cette attente, les mots Cool On (ouHeat On si le systme utilis est une thermopompe) clignotent lcran. Adaptive Intelligent Recovery : Cette caractristique qui vite des tton-
nements lutilisateur au moment dtablir son horaire. Elle permet au ther-
mostat dapprendre combien de temps il faut au systme de chauffage ou de refroidissement pour atteindre la temprature souhaite pour que la tem-
prature dsire soit atteinte lheure prvue. Remarque : Quand la fonction de reprise auto-adaptative est en service, le thermostat affiche Recovery. 55 Remplacement des piles (thermostat) Appuyer et tirer pour retirer les piles Insrer deux piles alca-
lines neuves de taille AA, puis remettre en place le porte-piles Installer des piles neuves lorsque lavertissement de remplacement des piles REPLACE BATTERY commence clignoter lcran. Ce message clignote pendant environ deux mois avant que les piles ne soient compltement puises. Retirer le porte-piles et insrer 2 piles neuves alcalines AA. Une fois les piles insres, le thermostat rtablira automatiquement la communica-
tion avec le rseau sans fil au bout de quelques minutes. Remarque : Si les piles sont insres moins de 2 minutes), il ne sera pas ncessaire de rgler nouveau lheure et le jour. 56 Remplacement des piles (capteur dair extrieur) Retirer le capteur de son support Remplacer les piles du capteur extrieur lorsque lavertissement REPLACE BATTERY OUT-
DOOR commence clignoter au thermostat. Ce message clignote pendant environ deux mois avant que les piles ne soient compltement puises. Retirer le capteur de son support, retirer le couvercle et insrer deux piles AA neuves au lithium. Une fois les piles insres, le capteur rtablira automatiquement la communica-
tion avec le rseau sans fil au bout de quelques minutes. 57 Retirer le couvercle et installer deux piles AA neuves au lithium En cas de difficult Le systme de chauffage ou de refroidissement ne rpond pas
Sassurer que le coupe-circuit nest pas dclench et le remettre en position de marche au besoin.
Sassurer que le bouton de marche-arrt du systme de chauffage ou de refroidissement est la position de marche.
Sassurer que la porte de lappareil de chauffage est bien ferme.
Attendre 5 minutes pour laisser au systme le temps de ragir. Lcran affiche No signal Le thermostat a perdu le signal radio avec le rseau sans fil (habituellement la suite dune panne de courant). Pour rtablir lalimentation :
Sassurer que le coupe-circuit nest pas dclench et le remettre en position de marche au besoin.
Sassurer que le bouton de marche-arrt du systme de chauffage ou de refroidissement est la position de marche.
Sassurer que la porte de lappareil de chauffage est bien ferme. Une fois lalimentation rtablie, le thermostat rtablira automatiquement la communication avec le rseau sans fil au bout de quelques minutes. 58 Garantie limite jusqu 5 ans Honeywell garantit ce produit, lexception de la pile, contre tout vice de fabrication ou de matire dans la mesure o il en est fait une utilisation et un entretien convenables, et ce, pour trois (3) ans partir de la date dachat par le consommateur. En cas de dfectuosit ou de mauvais fonctionnement pendant la priode de garantie, Honeywell remplacera ou rparera le produit (au gr de Honeywell) dans un dlai raisonnable. Si le produit est dfectueux,
(i) le retourner, accompagn dune preuve dachat indiquant la date dachat, au dtaillant auprs de qui il a t achet, ou
(ii) sadresser au Service la clientle de Honeywell en composant le 1-800-468-1502. Les Services la clientle dtermineront alors si le produit doit tre retourn ladresse suivante : Honeywell Return Goods, Dock 4 MN 10-
3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, ou si un produit de remplacement peut vous tre expdi. La prsente garantie ne couvre pas les frais de retrait ou de rinstallation. La prsente garantie ne sappliquera pas sil est dmontr que la dfectuosit ou le mauvais fonction-
nement est d un endommagement du produit alors que le consommateur lavait en sa possession. La responsabilit de Honeywell se limite rparer ou rem-
placer le produit conformment aux modalits susmention-
nes. HONEYWELL NEST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES, Y COMPRIS LES DOM-
MAGES INDIRECTS OU ACCESSOIRES DCOULANT DIRECTEMENT OU INDIRECTEMENT DUNE VIOLATION 59 QUELCONQUE DUNE GARANTIE, EXPRESSE OU TACITE, APPLICABLE AU PRSENT PRODUIT NI DE TOUTE AUTRE DFECTUOSIT DU PRSENT PRODUIT. Certaines provinces ne permettent pas lexclusion ou la restriction des dommages indirects et, par consquent, la prsente restriction peut ne pas sappliquer. LA PRSENTE GARANTIE TIENT LIEU DE TOUTES LES AUTRES GARANTIES EXPRESSES ACCORDES PAR HON-
EYWELL POUR CE PRODUIT, ET LES GARANTIES DE VALEUR MARCHANDE ET DE CONFORMIT UNE FIN PARTICULIRE SONT PAR LES PRSENTES EXCLUES APRS LA PRIODE DE UN AN DE LA PRSENTE GARANTIE. Certaines provinces ne permettent pas de limiter la dure des garanties tacites et, par consquent, la prsente limitation peut ne pas sappliquer. La prsente garantie donne au consommateur des droits lgaux spcifiques et peut-tre certains autres droits qui peuvent varier dune province lautre Pour toute question concernant la prsente garantie, prire dcrire aux Services la clientle de Honeywell ladresse suivante : Honeywell Customer Relations, 1985 Douglas Drive, Golden Valley, MN 55422, ou encore composer le 1-800-468-1502. Au Canada, prire de sadresser au service des Produits de dtail, Honeywell Limited/Honeywell Limite, 35, Dynamic Drive, Scarborough (Ontario) M1V 4Z9. Lorsque le produit est inscrit en ligne ladresse www.warranty.Honeywell.com, la garantie standard du fabri-
cant dcrite ci-dessus est prolonge jusqu cinq (5) ans. Regulatory information FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:
1 This device may not cause harmful interference, and 2 This device must accept any interference received, includ-
ing interference that may cause undesired operation. FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa-
tion. This equipment generates uses and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the inter-
ference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. Exposure Limits To comply with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a sepa-
ration distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Industry Canada Statement per Section 4.0 of RSP-100 The term "IC:" before the certification / registration number only signifies that the Industry Canada technical specifica-
tions were met. Industry Canada Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions:
1 this device may not cause interference, and 2 this device must accept any interference, including interfer-
ence that may cause undesired operation of the device. Limites dexposition Pour tre conformes aux limites dexposition aux radiofrquences tablies par la FCC et Industrie Canada pour le grand public/lexposition non contrle, la ou les antennes employes par le transmetteur doivent tre installes sur une structure extrieure permanente au moins 20 cm de distance de toute personne et ne peuvent tre situes au mme endroit quune autre antenne ou un autre transmetteur ou fonctionner conjointement avec une autre antenne ou un autre transmetteur. Dclaration dIndustrie Canada selon larticle 4.0 de la PNR-100 Les lettres IC devant le numro dinscription/homologation signifient que lappareil respecte les normes techniques dIndustrie Canada. Industrie Canada Alina 7.1.5 de CNR-GEN Le fonctionnement de ce systme est assorti aux deux conditions suivantes :
1 Lappareil ne peut causer dinterfrences nuisibles, et 2 Lappareil doit accepter les interfrences reues, y compris celles qui pourraient nuire son fonctionnement. 60 Informacin reguladora Declaracin de conformidad con las regulaciones FCC
(Seccin 15.19) (solo en los EE. UU.) Este dispositivo cumple con la Seccin 15 de las regulaciones FCC. El funcionamiento est sujeto a las dos condiciones siguientes:
1 Este dispositivo no debe causar interferencia perjudicial. 2 Este dispositivo deber aceptar cualquier interferencia que se reciba, incluso la interferencia que pudiese causar el fun-
cionamiento no deseado. Advertencia de la FCC (Seccin 15.21) (solo en los EE. UU.) Los cambios o las modificaciones que no hayan sido expre-
samente aprobados por la parte responsable del cumplimien-
to de las regulaciones podran anular la autoridad del usuario para hacer funcionar el equipo. Declaracin de la FCC sobre interferencias (Seccin 15.105(b)) (solo en los EE. UU.) Este equipo fue probado y cumple con los lmites de los dis-
positivos digitales clase B, conforme a la Seccin 15 de las regulaciones FCC. Estos lmites estn diseados para ofrecer una proteccin razonable contra la interferencia perjudicial en una instalacin residencial. Este equipo genera usos y puede irradiar energa de frecuencia de radio y, si no se instala y se utiliza segn las instrucciones, puede producir una interferencia perjudicial en la comunicacin radial. Sin embargo, no se garantiza que no habr interferencia en una instalacin particular. Si este equipo produce una interferencia perjudicial en la recepcin televisiva o radial, lo cual puede determinarse al apagar y encender el equipo, se recomienda que el usuario intente cor-
regir la interferencia con una o ms de las siguientes medidas:
Vuelva a orientar y ubicar la antena receptora.
Aumente la distancia entre el equipo y el receptor.
Conecte el equipo a un tomacorriente en un circuito difer-
ente a aquel en el que est conectado el receptor.
Consulte con su distribuidor o con un tcnico experto en radio/televisin para recibir ayuda. Lmites de exposicin Para cumplir con los lmites de exposicin RF que establecen la FCC y Industry Canada para la poblacin en gener-
al/exposicin no controlada, la o las antenas usadas para este transmisor deben instalarse a una distancia de separacin de, al menos, 20 cm de todas las personas, y no deben colocarse ni utilizarse junto con otra antena o transmisor. Declaracin de Industry Canada conforme a la Seccin 4.0 de RSP-100 El trmino IC: antes de la certificacin/el No. de registro solo significa que se cumplieron las especificaciones tcnicas de Industry Canada. Seccin de Industry Canada 7.1.5 de RSS-GEN El funcionamiento est sujeto a las dos condiciones sigu-
ientes:
1 Este dispositivo no debe causar interferencia. 2 Este dispositivo deber aceptar cualquier interferencia, incluso la interferencia que pudiese causar el funcionamiento no deseado del dispositivo. 61 For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 Need Help?
Consulte sobre este producto en http://yourhome.honeywell.com o llamando sin cargo a atencin al cliente de Honeywell 1-800-468-1502 Necesita ayuda?
Pour obtenir de lassistance concernant ce produit, visitez http://yourhome.honeywell.com ou appelez gratuitement lassistance client dHoneywell au 1-800-468-1502 Vous faut-il de laide ?
Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://yourhome.honeywell.com Honeywell Limited-Honeywell Limite 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 69-2093EFS-01 06-2008 2008 Honeywell International Inc. U.S. Registered Trademark. All rights reserved. Printed in USA.
1 | Manual 2 | Users Manual | 3.14 MiB |
System Installation Guide RedLINK Wireless System With TrueZONE Panel & Wireless Adapter Espaol: vea la pgina 16 Franais : voir la page 31 Provides wireless control of TrueZONE Panels. (See zone panel information for heat/cool stage capacity. ) Installation guide for:
FocusPRO wireless thermostats
Wireless remote control
Wireless outdoor air sensor DISCONNECT POWER BEFORE BEGINNING INSTALLATION. Can cause electrical shock or equipment damage. MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal. Must be installed by a trained, experienced technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. U.S. Registered Trademark. Copyright 2008 Honeywell International Inc. All rights reserved. RedLINK Installation Guide (TrueZONE) System installation at a glance Thermostat Thermostat Outdoor air sensor Remote control Wireless adapter TrueZONE panel HVAC equipment Installation procedure This document covers linking and installation procedures for FocusPRO wireless thermostats and RedLINK accessories in TrueZONE applications. Before you begin, you must mount, wire & configure the TrueZONE panel and wireless adapter (see TrueZONE Installation Guide), then follow steps below. 1 2 3 4 5 You must configure the TrueZONE panel before you begin Install batteries in wireless devices ................................Page 3 Link all devices to wireless network ..........................Pages 3-5 Exit wireless setup ............................................................Page 6 Customize thermostat (installer setup) ....................Pages 6-10 Mount thermostat and outdoor sensor..........................Page 11 To replace system components if needed, see page 13 If you have more than one TrueZONE Panel: Thermostats are linked to specific zone panels. Optional accessories must be linked to each zone panel separately. 2 Espaol: vea la pgina 16 Franais : voir la page 31 1 Install batteries in wireless devices When system wiring is complete and TrueZONE panel is configured for RF, install batteries in all devices. Make sure batteries are inserted properly (see illustrations below). Thermostat Install 2 fresh AA batteries Programmable models only Install quick reference card Remote control (optional) Outdoor air sensor (optional) Install 3 fresh AA batteries Install 2 fresh AA lithium batteries 2 Link all devices to wireless network Press CONNECT Make sure the Connected light on the wireless adapter is flashing green. If the light stops flashing before you have linked all devices, press CONNECT again. If light does not flash, another EIM/wireless adapter may be in wireless setup mode. Exit wireless setup at the other EIM/wireless adapter. Flashing status light times out after 15 minutes of inactivity. Press CONNECT again if necessary. 3 Continued on next page >>
RedLINK Installation Guide (TrueZONE) Link thermostats to wireless network Zone number Wireless Setup0 1 Back Next Press or to set a zone number for this thermostat (1 to 4), then press NEXT. Zone name Wireless Setup 36 52 Press or to change the name or location of this zone, then press NEXT. Example: 31 = Living room Back Next See complete zone list on page 8 Wireless Setup Wireless Setup Press CONNECT to establish a link to the wireless network. If E1 appears, see error codes on page 12. Back Connect Wireless Setup Wireless Setup Connected Done After a brief pause, the confirmation screen at left should be displayed, to verify that the wireless connection has been established. Press DONE to display the home screen. 4 Link remote control to wireless network (optional) Espaol: vea la pgina 16 Franais : voir la page 31 CONNECT WIRELESS SETUP Press to link another zone panel Press to save and exit YES NO CONNECT MORE?
1 Make sure the Connected light on the wireless adapter is flashing. 2 Press CONNECT at the remote. There will be a short delay as the remote seeks a signal from the wireless network. 3 When the screen displays Connected, press DONE. 4 Press NO at the next screen to save and exit. (Or press YES and repeat steps 1-4 to link another zone panel.) If E1 appears, see error codes on page 12. The linking procedure may time out if there is no keypress within 30 minutes. To begin again, press and hold the blank space (or arrow if present) in the lower right corner of the screen until the display changes (about 3 seconds) Link outdoor sensor to wireless network (optional) Press and release 1 Make sure the Connected light on the wireless adapter is flashing. 2 Press the CONNECT button on the back of the sensor. 3 Check thermostat to verify that the outdoor sensor is working. After about 15 seconds, the thermostat should display outdoor temperature and humidity.
(If you are installing more than one zone panel, repeat steps 1-3 for each.) 5 RedLINK Installation Guide (TrueZONE) 3 Exit wireless setup Press CONNECT at the wireless adapter to exit wireless setup (light should stop flashing). Note: The wireles adapter will automatically exit wireless setup after 15 minutes of inactivity. Note: If installing more than one zone panel, you must exit wireless setup before installing an additional zone panel. 4 Customize thermostat (installer setup) Follow the steps below to begin installer setup. At each function screen, press or to change the setting as desired, then press NEXT to advance to the next function screen. See tables on pages 7-9 for a description of options for each function. 0 1 Done Back Next Press or to change setting
(see tables on pages 7-9) FAN To begin, press and hold the FAN and buttons until the display changes (about 3 seconds). Function Setting 1 0 Done Back Next Press NEXT to display next function screen Press DONE to save & exit. 6 Espaol: vea la pgina 16 Franais : voir la page 31 Installer setup tables Setup functions Settings & Options (factory default in bold) 0 1 2 3 5 6 7 8 9 10 12 13 14 Zone number System type 0 No zoning (single thermostat used with THM5320R EIM)
[Options: select zone 1, 2, 3 or 4]
0 1 heat/1 cool conventional 1 1 heat/1 cool heat pump (no aux. heat) 2 Heat only (includes Series 20) 3 Heat only with fan 4 Cool only 5 2 heat/1 cool heat pump 6 2 heat/2 cool conventional 7 2 heat/1 cool conventional 8 1 heat/2 cool conventional 9 2 heat/2 cool heat pump 10 3 heat/2 cool heat pump Changeover valve
(O/B terminal) 0 O/B terminal controls valve in cooling 1 O/B terminal controls valve in heating Fan control
(conventional heat) 0 Gas/Oil heat (equipment controls fan) 1 Electric furnace (thermostat controls fan) Stage 1 heat cycle rate (CPH= cycles per hour) Stage 2 heat cycle rate (CPH) Stage 3 heat cycle rate (CPH) 5 Gas or oil furnaces (less than 90% efficiency) 1 Steam or gravity systems 3 Hot water systems & furnaces of over 90% efficiency 9 Electric furnaces
[Cycle rate options: 1 to 12 CPH]
5 Gas or oil furnaces (less than 90% efficiency) 1 Steam or gravity systems 3 Hot water systems & furnaces of over 90% efficiency 9 Electric furnaces
[Cycle rate options: 1 to 12 CPH]
5 Gas or oil furnaces (less than 90% efficiency) 1 Steam or gravity systems 3 Hot water systems & furnaces of over 90% efficiency 9 Electric furnaces
[Cycle rate options: 1 to 12 CPH]
Emergency heat cycle rate (CPH) 9 Electric furnace
[Cycle rate options: 1 to 12 CPH]
Stage 1 compres-
sor cycle rate 3 Recommended cycle rate
[Cycle rate options: 1 to 6 CPH]
Stage 2 compres-
sor cycle rate 3 Recommended cycle rate
[Cycle rate options: 1 to 6 CPH]
Manual/Auto changeover 0 Manual (User options: Heat/Cool/Off) 1 Automatic (User options: Heat/Cool/Auto/Off) Adaptive Intelligent Recovery Applies only to Model TH6320 0 Off **
1 On Temperature display 0 Fahrenheit 1 Celsius
** See page 9 7 RedLINK Installation Guide (TrueZONE) Installer setup tables Setup functions Settings & Options (factory default in bold) 15 Compressor off time (minimum) 5 5 minute compressor off time **
[Options: 0 to 4 minutes]
16 Schedule format Applies only to Model TH6320 0 Weekday/weekend program schedule 1 Weekday/Saturday/Sunday program schedule 26 27 28 32 33 35 Auxiliary heat control Maximum heat setpoint Minimum cool setpoint Temp. display offset (indoor) Applies only to Model TH5320 0 Comfort **
1 Economy 90 Max. heat temperature setting is 90F (32C)
[Options: 40 to 90F (4.5 to 32C)]
50 Min. cool temperature setting is 50F (10C)
[Options: 50 to 99F (10 to 37C)]
0 Thermostat displays actual temperature
[Options: -3 to +3F offset (-1.5 to +1.5C)]
Temp. display offset (outdoor) 0 Thermostat displays actual temperature
[Options: -5 to +5F offset (-2.5 to +2.5C)]
Humidity display offset (outdoor) 3 Thermostat displays actual humidity
[Other options: 0 = -15%, 1 = -10%, 2 = -5%, 4 = 5%, 5 = 10%, 6 = 15% offset]
36 Zone name 39 Wireless setup 90 RESET 52 Thermostat 1 Basement 2 Bathroom 3 Bathroom 1 4 Bathroom 2 5 Bathroom 3 6 Bedroom 7 Bedroom 1 8 Bedroom 2 9 Bedroom 3 10 Bedroom 4 11 Boat House 12 Bonus Room 13 Computer Room 14 Den 15 Dining Room 16 Exercise Room 17 Family Room 18 Fireplace 19 Foyer 20 Game Room 21 Garage 22 Great Room 23 Guest Room 24 Gym 25 Kids Room 26 Kitchen 27 Kitchen 1 28 Kitchen 2 29 Laundry Room 30 Library 31 Living Room 32 Lower Level 33 Master Bath 34 Master Bed 35 Media Room 36 Music Room 37 Nursery 38 Office 39 Office 1 40 Office 2 41 Pantry 42 Play Room 43 Pool Room 44 Porch 45 Rec Room 46 Sewing Room 47 Spa 48 Storage Room 49 Studio 50 Sun Room 51 Theater 52 Thermostat 53 Upper Level 54 Utility Room 55 Walk In Closet 56 Wine Cellar 57 Workshop 0 Disconnect thermostat from wireless system 1 Thermostat is connected to wireless system 0 No reset 1 Reset installer options & program schedule to factory default settings
** See page 9 8 Special functions Espaol: vea la pgina 16 Franais : voir la page 31 Adaptive Intelligent Recovery (Setup Function 13): Allows the thermostat to learn how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the scheduled time. Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During this time, Heat On/Cool On flashes on the display. Comfort/Economy (Setup Function 26):
If you choose Comfort, auxiliary heat will respond quickly to meet the temperature setpoint. If you choose Economy, the system will wait longer. Auxiliary heat will be activated only if the setpoint is not reached within a reasonable time. 9 RedLINK Installation Guide (TrueZONE) System test Follow the procedure below to test for proper operation. System test number 02 System status 0 Done Back Next Press or to check system status Press NEXT to advance to next test Press DONE to terminate system test To begin, press and hold the and buttons until the display changes (about 3 seconds) System Test System Status 02 Wireless test 10 Heating system 0 Off 1 Test radio signal (after a brief pause, screen displays 1-10 to show signal strength; 5 or higher recommended) 0 Heat and fan turn off 1 Heat turns on 2 Stage 2 heat turns on 3 Stage 3 heat turns on 20 Emergency heating system 0 Heat and fan turn off 1 Heat and fan turn on 30 Cooling system 0 Compressor and fan turn off 1 Compressor and fan turn on 2 Stage 2 compressor turns on 40 Fan system 0 Fan turns off 1 Fan turns on 70 Thermostat information
(for reference only) 71 Software revision number (major revisions) 72 Software revision number (minor revisions) 73 Configuration identification code (major) 74 Configuration identification code (minor) 75 Production configuration date code (week) 76 Production configuration date code (year) CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection (minimum off time) is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly. 10 5 Mount thermostat & outdoor sensor Espaol: vea la pgina 16 Franais : voir la page 31 3/16 holes for drywal 7/32 holes for plaster Mounting screw Wall anchor Detach wallplate Wallplate Outdoor sensor (optional) Mount the sensor on a vertical exterior wall, at least 6 inches below any overhang. Choose a location protected from direct sunlight. Place sensor securely in bracket, facing away from wall Press and release To check location before mounting: Restore thermostat Home screen, then hold the sensor where you intend to install it and press the CONNECT button. If sensor is working properly, thermostat will switch to display outdoor temperature and humidity. 11 RedLINK Installation Guide (TrueZONE) Verify proper setup When wireless setup is complete, make sure the Connected light on the wireless adapter is solid green (see below), then follow the steps in the Checkout section of the TrueZONE installation guide to verify proper operation. Wireless status light
Solid green: wireless adapter is working properly and communicating with wireless devices.
Flashing green: Linking to wireless devices (light flashes for 15 minutes after you press CONNECT).
Solid red: Communication problem. Check wireless adapter and other wireless devices. Error codes (thermostat & remote control) If E1 appears during setup, check error code number (right side of screen):
Attempting to connect incompatible wireless devices. Verify that thermostat zone number matches number assigned at zone panel. Verify that this zone number is configured at the zone panel as an RF thermostat. Low signal strength. Move wireless device to a different location and try again. 29 30 31 34 38 Make sure Connected light on wireless adapter is flashing and you are 2+ feet away from wireless adapter. 12 Espaol: vea la pgina 16 Franais : voir la page 31 Replacing system components Thermostat To replace a thermostat, install batteries and follow the procedure on page 4 to link it to the wireless network. If necessary, modify settings as needed
(see tables on pages 7-9). Remote control & outdoor sensor To replace a remote control or outdoor air sensor, install batteries and follow the procedure on page 5 to link it to the wireless network. TrueZONE panel & wireless adapter After installing a new zone panel or wireless adapter, you must re-set the thermostat and remote control to communicate with the new equipment, as described below. At the thermostat:
1 Press and hold the FAN and buttons for 3 seconds. 2 Press BACK twice to display Function 39 (wireless setup). 3 Press to change Function 39 setting to 0 (disconnect from old equipment). 4 Follow the procedure on page 4 to link to new equipment. At the remote control:
1 Press and hold the blank space (or arrow if present) in the lower right corner of the screen until the display changes (about 3 seconds). 2 Press REMOVE , then YES to disconnect from old equipment. 3 Follow the procedure on page 5 to link to new equipment. Press and hold for about 3 seconds 13 RedLINK Installation Guide (TrueZONE) Specifications & replacement parts Operating Ambient Temperature Thermostat: 32 to 120 F (0 to 48.9 C) Remote control: 32 to 120 F (0 to 48.9 C) Wireless Adapter: -40 to 165 F (-40 to 73.9 C) Outdoor air sensor: -40 to 140 F (-40 to 60 C) Operating Relative Humidity Thermostat: 5% to 90% (non-condensing) Remote control: 5% to 90% (non-condensing) Wireless Adapter: 5% to 95% (non-condensing) Outdoor air sensor: 0% to 100% (condensing) Physical Dimensions (height, width, depth) Thermostat: 3-9/16 x 5-13/16 x 1-1/2 inches (91 x 147 x 38 mm) Wireless Adapter: 5-9/16 x 4-3/8 x 1-1/4 inches (141 x 112 x 32 mm) Outdoor air sensor: 5 x 3-1/2 x 1-11/16 inches (127 x 89 x 43 mm) Accessories & Replacement Parts Item Wireless adapter FocusPRO wireless thermostat (programmable) FocusPRO wireless thermostat (non-programmable) Remote control Outdoor air sensor Battery holder Cover plate (covers marks left by old thermostats) Part Number THM4000R1000 TH6320R1004 TH5320R1002 REM5000R1001 C7089R1013 50007072-001 50002883-001 14 Espaol: vea la pgina 16 Franais : voir la page 31 Regulatory information FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation. FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver. connected.
Consult the dealer or an experienced radio/TV technician for help. Wireless adapter, thermostats and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for general population/ uncon-
trolled exposure, the antenna(s) used for these transmitters must be installed to provide a sep-
aration distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Remote control This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure. Industry Canada Statement per Section 4.0 of RSP-100 The term "IC:" before the certification / registration number only signifies that the Industry Canada technical specifications were met. Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions:
1 this device may not cause interference, and 2 this device must accept any interference, including interference that may cause undesired operation of the device. 15 Gua de instalacin del sistema Sistema inalmbrico RedLINK Con panel TrueZONE y adaptador inalmbrico Espaol: vea la pgina 16 Franais : voir la page 31 Permite el control inalmbrico de los paneles TrueZONE. (Vea la informacin sobre el panel de zona para conocer la capacidad de las etapas de calefaccin/refrigeracin). Gua de instalacin para:
Termostatos inalmbricos FocusPRO
Control remoto inalmbrico
Sensor de aire exterior inalmbrico DESCONECTE LA ENERGA ANTES DE COMENZAR LA INSTALACIN. Puede causar una descarga elctrica o daos al equipo. AVISO SOBRE MERCURIO: si este producto reemplaza un control que contiene mer-
curio en un tubo sellado, no coloque el control anterior en la basura. Comunquese con la oficina de gestin de residuos de su localidad para obtener instrucciones sobre cmo reciclar o desechar el producto de manera adecuada. La instalacin debe ser realizada por un tcnico capacitado y experimentado. Lea detenidamente estas instrucciones. Si no sigue estas instrucciones, corre el riesgo de daar el producto o de provocar una situacin peligrosa. Marca registrada de los EE. UU. Copyright 2008 Honeywell International Inc. Todos los derechos reservados. Instalacin rpida del sistema Espaol: vea la pgina 16 Franais : voir la page 31 Termostato Termostato Sensor de aire exterior Control remoto Adaptador inalmbrico Panel TrueZONE Equipo de HVAC Procedimiento de instalacin Este documento incluye los procedimientos de conexin e instalacin de los termostatos inalmbricos FocusPRO y de los accesorios RedLINK en las aplicaciones TrueZONE. Antes de comenzar, debe instalar, conectar y configurar el panel TrueZONE y el adaptador inalmbrico (vea la Gua de instalacin TrueZONE), luego siga los pasos que se detallan a continuacin. 1 2 3 4 5 Debe configurar el panel TrueZONE antes de comenzar Instalacin de las bateras en los dispositivos inalmbricos........... ...................................Pg. 18 Conexin de los dispositivos a la red inalmbrica ....Pgs. 18-20 Salida del modo Wireless Setup ....................................Pg. 21 Personalizacin del termostato
(configuracin de instalacin) ................................Pgs. 21-25 Instalacin del termostato y del sensor exterior.........................................................Pg. 26 Si necesita reemplazar los componentes del sistema, vea la pg. 28 Si tiene ms de un panel TrueZone: los termostatos se conectan a paneles de zona especficos. Los accesorios opcionales se pueden conectar a cada panel de zona por separado. 17 RedLINK Installation Guide (TrueZONE) 1 Instalacin de las bateras en los dispositivos inalmbricos Cuando el cableado del sistema est completo y el panel TrueZONE est configurado para RF, coloque las bateras en todos los dispositivos. Compruebe que las bateras estn insertadas correctamente (refirase a la ilustracin de ms abajo). Termostato Solo en modelos programables Instale 2 bateras AA nuevas Instale la tarjeta de referencia rpida Control remoto (opcional) Sensor de aire exterior (opcional) Instale 3 bateras AA nuevas Instale 2 bateras AA de litio nuevas 2 Conexin de los dispositivos a la red inalmbrica Presione CONNECT Asegrese de que la luz de Connected en el adaptador inalmbrico est destellando en color verde. Si la luz deja de destellar antes de que conecte los dispositivos, presione CONNECT nuevamente. La luz intermitente deja de destellar despus de 15 minutos de inactividad. Presione CONNECT nuevamente si es necesario. Si la luz no destella, es posible que otro EIM/adaptador inalmbrico est en el modo Wireless Setup. Salga del modo Wireless Setup en el otro EIM/adaptador inalmbrico. Contina en la pg. siguiente >>
18 Conexin del termostato a la red inalmbrica Espaol: vea la pgina 16 Franais : voir la page 31 Nmero de zona Wireless Setup0 1 Presione o para configurar un nmero de zona para este termostato (de 1 a 4) y luego presione NEXT. Back Next Nombre de zona Wireless Setup 36 52 Presione o para cambiar el nombre o la ubicacin de esta zona y luego presione NEXT. Ejemplo: 31 = Living room Back Next Vea la lista completa de zonas en la pg. 23. Wireless Setup Wireless Setup Presione CONNECT para establecer una conexin a la red inalmbrica. Si aparece E1, vea los cdigos de error en la pg. 33. Back Connect Wireless Setup Wireless Setup Connected Done Despus de una pausa breve, debe aparecer la pantalla de confirmacin a la izquierda, para verificar que se estableci la conexin inalmbrica. Presione DONE para mostrar la pantalla principal. 19 RedLINK Installation Guide (TrueZONE) Conexin del control remoto a la red inalmbrica (opcional) CONNECT WIRELESS SETUP 1 Asegrese de que la luz de Connected en panel de zona est destellando. 2 Presione CONNECT en el control remoto. Habr una breve demora mientras el control remoto busca una seal procedente de la red inalmbrica. Presione para conectar otro otro panel de zona Presione para guardar y salir 3 Cuando la pantalla muestre Connected, presione DONE. YES NO CONNECT MORE?
4 En la pantalla siguiente, presione NO para guardar y salir. (O presione YES y repita los pasos del 1 al 4 para conectar otro panel de zona). Si aparece E1, vea los cdigos de error en la pg. 27. Es posible que el procedimiento de conexin se interrumpa si no presiona ninguna tecla en 30 minutos. Para volver a comenzar, presione y mantenga presionado el espacio en blanco
(o la flecha, si la hubiera) en la esquina inferior derecha de la pantalla hasta que la visualizacin cambie (3 segundos, aprox.) Conexin del sensor exterior a la red inalmbrica (opcional) Presione y suelte 1 Asegrese de que la luz de Connected en panel de zona est destellando. 2 Presione el botn CONNECT en la parte posterior del sensor. 3 Controle el termostato para compro-
bar que el sensor exterior est fun-
cionando. Despus de unos 15 segundos, el termostato debe mostrar la temperatura y la humedad exteriores. (Si est instalando ms de un panel de zona, repita los pasos del 1 al 3 con cada uno). 20 Espaol: vea la pgina 16 Franais : voir la page 31 3 Salida del modo Wireless Setup Presione CONNECT en panel de zona para salir del modo Wireless Setup (la luz debe dejar de destellar). Nota: el panel de zona saldr automticamente del modo Wireless Setup despus de 15 minutos de inactividad. Nota: si est instalando ms de un panel de zona, debe salir del modo Wireless Setup antes de instalar un panel de zona adicionales. 4 Personalizacin (configuracin de instalacin) Siga los pasos que se detallan a continuacin para comenzar la configu-
racin de instalacin. En cada pantalla de funciones, presione o para cambiar la configuracin segn lo desee, luego presione NEXT para avanzar hasta la siguiente pantalla de funciones. Vea las tablas de las pgs. 22 a 24 para obtener una descripcin de las opciones de cada funcin. FAN 0 1 Done Back Next Para comenzar, presione y mantenga presionados los botones FAN y hasta que la visualizacin cambie (3 segundos, aprox.) Funcin Configuracin 1 0 Presione o para cambiar la con-
figuracin (vea las tablas de las pgs. 28 a 30) Done Back Next Presione NEXT para mostrar la siguiente pantalla de funciones Presione DONE para guardar y salir 21 RedLINK Installation Guide (TrueZONE) Tablas de la configuracin de instalacin Funciones Opciones (Negrita: las configuraciones predeterminadas ) 0 1 2 3 5 6 7 8 9 10 12 13 14 Nmero de zona 0 Sin zona (se utiliza un solo termostato con el EIM THM5320R)
[opciones: seleccione la zona 1, 2, 3 4]
Tipo de sistema 0 Convencional 1 calentador/1 refrigerador 1 Bomba de calor 1 calentador/1 refrigerador (sin AuxHeat) 2 Calefaccin nicamente (incluye la Serie 20) 3 Calefaccin nicamente con ventilador 4 Refrigeracin nicamente 5 Bomba de calor de 2 calentadores/1 refrigerador 6 Convencional de 2 calentadores/2 refrigeradores 7 Convencional de 2 calentadores/1 refrigerador 8 Convencional de 1 calentador/2 refrigeradores 9 Bomba de calor de 2 calentadores/2 refrigeradores 10 Bomba de calor de 3 calentadores/2 refrigeradores Vlvula de cambio
(terminal O/B) 0 El terminal O/B controla la vlvula en la refrigeracin 1 El terminal O/B controla la vlvula en la calefaccin Ventilador (calefac-
cin convencional) 0 Calefaccin a gas/aceite (el quipo controla el ventilador) 1 Calefaccin elctrico (el termostato controla el ventilador) ndice del ciclo de calefaccin en la etapa 1 (CPH =
ciclos por hora) Calefaccin en la etapa 2 (CPH) Calefaccin en la etapa 3 (CPH) 5 Calefaccin a gas o aceite (< 90% de eficacia) 1 Sistemas por vapor o gravedad 3 Sistemas por agua caliente y calefaccin > 90% de eficacia 9 Sistemas de calefaccin elctricos
[Opciones de ndices de ciclos: de 1 a 12 CPH]
5 Calefaccin a gas o aceite (< 90% de eficacia) 1 Sistemas por vapor o gravedad 3 Sistemas por agua caliente y calefaccin > 90% de eficacia 9 Sistemas de calefaccin elctricos
[Opciones de ndices de ciclos: de 1 a 12 CPH]
5 Calefaccin a gas o aceite (< 90% de eficacia) 1 Sistemas por vapor o gravedad 3 Sistemas por agua caliente y calefaccin > 90% de eficacia 9 Sistemas de calefaccin elctricos
[Opciones de ndices de ciclos: de 1 a 12 CPH]
Calefaccin de emergencia (CPH) 9 Sistemas de calefaccin elctricos
[Opciones de ndices de ciclos: de 1 a 12 CPH]
Compresor en la etapa 1 3 ndice recomendado de ciclos
[Opciones de ndices de ciclos: de 1 a 6 CPH]
Compresor en la etapa 2 3 ndice recomendado de ciclos
[Opciones de ndices de ciclos: de 1 a 6 CPH]
Cambio manual/
automtico 0 Manual (opciones para el usuario: Heat/Cool/Off) 1 Automtico (opciones para el usuario: Heat/Cool/Auto/Off) Adaptive Intelligent Recovery Se aplica solo al modelo TH6320 0 Apagado **
1 Encendido Indicador de temperatura 0 Fahrenheit 1 Celsius
** Vea la pg. 24 22 Tablas de la configuracin de instalacin Espaol: vea la pgina 16 Franais : voir la page 31 Funciones Opciones (Negrita: las configuraciones predeterminadas ) Tiempo apagado del compresor (mn.) 5 5 minutos
[Opciones: 0 a 4 minutos] **
Formato del cronograma Se aplica solo al modelo TH6320 0 Cronograma para das de semana/fin de semana 1 Cronograma para das de semana/sbado/domingo Control de la cale-
faccin auxiliar Se aplica solo al modelo TH5320 0 Confort **
1 Economa Punto de referen-
cia de calor (mx.) Punto de referen-
cia de fro (mn.) 90 La temperatura de calefaccin mx. es de 90F (32C)
[Opciones: 40 a 90F (4,5 a 32C)]
50 La temperatura de refrigeracin mn. es de 50F (10C)
[Opciones: 50 a 99F (10 a 37C)]
Ajuste pantalla de temp. (interiores) 0 El termostato muestra la temperatura real
[Opciones: ajuste de -3 a +3F offset (-1,5 a +1,5C)]
Ajuste pantalla de temp. (exteriores) 0 El termostato muestra la temperatura real
[Opciones: ajuste de -5 a +5F offset (-2,5 a +2,5C)]
Ajuste pantalla de humedad
(exteriores) Nombre de la zona 15 16 26 27 28 32 33 35 36 3 El termostato muestra la humedad real
[Opciones: ajuste de 0 = -15%, 1 = -10%, 2 = -5%, 4 = 5%, 5 = 10%, 6 = 15% offset]
52 Thermostat 1 Basement 2 Bathroom 3 Bathroom 1 4 Bathroom 2 5 Bathroom 3 6 Bedroom 7 Bedroom 1 8 Bedroom 2 9 Bedroom 3 10 Bedroom 4 11 Boat House 12 Bonus Room 13 Computer Room 14 Den 15 Dining Room 16 Exercise Room 17 Family Room 18 Fireplace 19 Foyer 20 Game Room 21 Garage 22 Great Room 23 Guest Room 24 Gym 25 Kids Room 26 Kitchen 27 Kitchen 1 28 Kitchen 2 29 Laundry Room 30 Library 31 Living Room 32 Lower Level 33 Master Bath 34 Master Bed 35 Media Room 36 Music Room 37 Nursery 38 Office 39 Office 1 40 Office 2 41 Pantry 42 Play Room 43 Pool Room 44 Porch 45 Rec Room 46 Sewing Room 47 Spa 48 Storage Room 49 Studio 50 Sun Room 51 Theater 52 Thermostat 53 Upper Level 54 Utility Room 55 Walk In Closet 56 Wine Cellar 57 Workshop 0 Desconecte el termostato del sistema inalmbrico 1 El termostato est conectado al sistema inalmbrico 0 Sin reinicio 1 Restablezca las opciones de instalacin y programe el cronograma segn las configuraciones predeterminadas
** Vea la pg. 24 23 39 Configuracin inalmbrica 90 REINICIO RedLINK Installation Guide (TrueZONE) Funciones especiales Adaptive Intelligent Recovery (funcin de configuracin 13): permite que el termostato sepa cunto demora el sistema de calefaccin y el aire acondicionado para alcanzar las configuraciones de temperatura programadas, de manera que se alcance esa temperatura a la hora programada. Proteccin del compresor (funcin de configuracin 15): hace que el compresor demore unos minutos antes de volver a iniciarse, para evitar daos. Durante este momento de espera, aparece el mensaje Heat On/Cool On en la pantalla. Confort/economa (funcin de configuracin 26):
Si elige la opcin confort, la calefaccin auxiliar responder rpidamente para alcanzar el punto de referencia de la temperatura. Si elige la opcin economa, el sistema demorar ms. La calefaccin auxiliar se activar solo si no se alcanza el punto de referencia en un tiempo razonable. 24 Espaol: vea la pgina 16 Franais : voir la page 31 Prueba del sistema Siga el procedimiento que se detalla a continuacin para verificar el funcionamiento adecuado. Nmero de la prueba del sistema 02 Estado del sistema 0 Done Back Next Para comenzar, presione y mantenga presionados los botones y hasta que la visualizacin cambie (3 segundos, aprox.) Presione o para verificar el estado del sistema Presione NEXT para avanzar Presione DONE para finalizar la prueba del sistema Prueba del sistema Estado del sistema 02 Prueba inalmbrica 10 Sistema de calefaccin 0 Apagado 1 Se prueba la seal de radio (luego de una pausa breve, la pantalla muestra de 1 a 10 para indicar la potencia de la seal;
se recomienda 5 o ms) 0 Se apagan la calefaccin y el ventilador 1 Se enciende la calefaccin 2 Se enciende la calefaccin en la etapa 2 3 Se enciende la calefaccin en la etapa 3 20 30 40 70 Calefaccin de emergencia 0 Se apagan la calefaccin y el ventilador 1 Se encienden la calefaccin y el ventilador Sistema de refrigeracin 0 Se apagan el compresor y el ventilador 1 Se encienden el compresor y el ventilador 2 Se enciende el compresor en la etapa 2 Sistema de ventilacin 0 Se apaga el ventilador 1 Se enciende el ventilador Informacin del termostato (solo para referencia) 71 Nmero de la revisin de software (revisiones ms importantes) 72 Nmero de la revisin de software (revisiones secundarias) 73 Cdigo de identificacin de la configuracin (ms importante) 74 Cdigo de identificacin de la configuracin (secundario) 75 Cdigo de la fecha de configuracin de la produccin (semana) 76 Cdigo de la fecha de configuracin de la produccin (ao) PRECAUCIN: RIESGO DE DAO AL EQUIPO. Se evita la proteccin del compresor
(tiempo de apagado mnimo) durante la prueba. Para prevenir daos al equipo, evite encender y apagar rpidamente el compresor. 25 RedLINK Installation Guide (TrueZONE) 5 Instalacin del termostato y del sensor exterior 3/16 (4,8 mm) para paneles de yeso 7/32 (5,6 mm) para yeso Tornillo de fijacin Tarugo de pared Placa de pared desmontable Sensor exterior (opcional) Placa de pared Instale el sensor en una pared exterior vertical, a 6 pulgadas (15,2 cm) como mnimo, debajo de cualquier alero. Elija una ubicacin donde no haya luz solar directa. Coloque bien el sensor en el soporte, orientado en direccin opuesta a la pared Presione y suelte Para verificar la ubicacin antes de instalarlo:
vuelva a la pantalla principal del termostato, luego sostenga el sensor donde desea instalarlo y presione el botn CONNECT. Si el sensor funciona correctamente, el termostato mostrar la temperatura y la humedad exteriores. 26 Espaol: vea la pgina 16 Franais : voir la page 31 Verificacin de la configuracin adecuada Una vez que haya finalizado la configuracin inalmbrica, asegrese de que la luz de Connected en el adaptador inalmbrico est de color verde fijo
(vea la ilustracin a continuacin) y luego siga los pasos de la seccin Revisin de la gua de instalacin de TrueZONE para verificar el funcionamiento correcto. Luz indicadora del estado de la comunicacin inalmbrica
Verde fijo: el adaptador inalmbrico funciona correctamente y se comunica con los dispositivos inalmbricos.
Verde intermitente: se est conectando a los dispositivos inalmbricos (la luz destella durante 15 minutos despus de que presiona CONNECT).
Rojo fijo: problemas con la comuni-
cacin. Controle el adaptador inalmbrico y los dems dispositivos inalmbricos. Cdigos de error (termostato y control remoto) Si aparece E1 durante la configuracin, vea el nmero del cdigo de error
(en el lado derecho de la pantalla):
29 30 31 34 38 Intenta conectar dispositivos inalmbricos incompatibles. Verifique que el nmero de zona del termostato concuerde con el nmero asignado en el panel de zona. Verifique que este nmero de zona est configurado en el panel de zona como un termostato RF. Baja potencia de seal. Mueva el dispositivo inalmbrico hacia otro lugar e intente nuevamente. Asegrese de que la luz de Connected en el adaptador inalmbrico est destellando y de que usted est a 2 pies (61 cm) o ms del adaptador inalmbrico. 27 RedLINK Installation Guide (TrueZONE) Reemplazo de los componentes del sistema Termostato Para reemplazar el termostato, instale las bateras y siga los procedimientos de la pg. 4 para conectarlo a la red inalmbrica. Si es preciso, modifique las configuraciones segn sea necesario (vea las tablas de las pgs. 22 a 24). Control remoto y sensor exterior Para reemplazar el control remoto o el sensor de aire exterior, instale las bateras y siga los procedimientos de la pg. 20 para conectarlo a la red inalmbrica. Panel TrueZONE y adaptador inalmbrico Despus de instalar un panel de zona o adaptador inalmbrico nuevo, vuelva a configurar el termostato y el control remoto para que tengan comunicacin con el equipo nuevo, como se describe a continuacin. En el termostato:
1 Presione y mantenga presionados los botones FAN y durante 3 segundos. 2 Presione BACK dos veces para mostrar la funcin 39 (modo Wireless Setup). 3 Presione para cambiar la configuracin de la funcin 39 a 0
(desconctelo del equipo anterior). 4 Siga el procedimiento de la pg. 19 para conectarlo al equipo nuevo. En el control remoto:
1 Presione y mantenga presionado el espacio en blanco (o la flecha, si la hubiera) en la esquina inferior derecha de la pantalla hasta que la visualizacin cambie (3 segundos, aprox.). 2 Presione REMOVE y luego YES para desconectarlo del equipo anterior. 3 Siga el procedimiento de la pg. 20 para conectarlo al equipo nuevo. Presione y mantenga presionado durante 3 segundos, aprox. 28 Espaol: vea la pgina 16 Franais : voir la page 31 Especificaciones y piezas de repuesto Temperatura ambiente de funcionamiento Termostato: 32 a 120 F (0 a 48,9 C) Control remoto: 32 a 120 F (0 a 48,9 C) Adaptador inalmbrico: -40 a 165 F (-40 a 73,9 C) Sensor de aire exterior: -40 a 140 F (-40 a 60 C) Humedad relativa de funcionamiento Termostato: 5% a 90% (sin condensacin) Control remoto: 5% a 90% (sin condensacin) Adaptador inalmbrico: 5% a 95% (sin condensacin) Sensor de aire exterior: 0% a 100% (condensacin) Dimensiones fsicas (altura, ancho, profundidad) Termostato: 3-9/16 x 5-13/16 x 1-1/2 pulgadas (91 x 147 x 38 mm) Adaptador inalmbrico: 8-1/8 x 8 x 1-7/8 pulgadas (206 x 203 x 47 mm) Sensor de aire exterior: 5 x 3-1/2 x 1-11/16 pulgadas (127 x 89 x 43 mm) Accesorios y piezas de repuesto Artculo Adaptador inalmbrico Termostato inalmbrico FocusPRO (programable) Termostato inalmbrico FocusPRO(no programmable) Control remoto Sensor de aire exterior Soporte de las bateras Placa de cubierta
(cubre las marcas que dejan los termostatos anteriores) Nmero de pieza THM4000R1000 TH6320R1004 TH5320R1002 REM5000R1001 C7089R1013 50007072-001 50002883-001 29 RedLINK Installation Guide (TrueZONE) Informacin reguladora Declaracin de conformidad con las regulaciones FCC (Seccin 15.19) (solo en los EE. UU.) Este dispositivo cumple con la Seccin 15 de las regulaciones FCC. El funcionamiento est sujeto a las dos condiciones siguientes:
1 Este dispositivo no debe causar interferencia perjudicial. 2 Este dispositivo deber aceptar cualquier interferencia que se reciba, incluso la interferencia que pudiese causar el funcionamiento no deseado. Advertencia de la FCC (Seccin 15.21) (solo en los EE. UU.) Los cambios o las modificaciones que no hayan sido expresamente aprobados por la parte responsable del cumplimiento de las regulaciones podran anular la autoridad del usuario para hacer funcionar el equipo. Declaracin de la FCC sobre interferencias (Seccin 15.105(b)) (solo en los EE. UU.) Este equipo fue probado y cumple con los lmites de los dispositivos digitales clase B, con-
forme a la Seccin 15 de las regulaciones FCC. Estos lmites estn diseados para ofrecer una proteccin razonable contra la interferencia perjudicial en una instalacin residencial. Este equipo genera usos y puede irradiar energa de frecuencia de radio y, si no se instala y se uti-
liza segn las instrucciones, puede producir una interferencia perjudicial en la comunicacin radial. Sin embargo, no se garantiza que no habr interferencia en una instalacin particular. Si este equipo produce una interferencia perjudicial en la recepcin televisiva o radial, lo cual puede determinarse al apagar y encender el equipo, se recomienda que el usuario intente corregir la interferencia con una o ms de las siguientes medidas:
Vuelva a orientar y ubicar la antena receptora.
Aumente la distancia entre el equipo y el receptor.
Conecte el equipo a un tomacorriente en un circuito diferente a aquel en el que est conec-
tado el receptor.
Consulte con su distribuidor o con un tcnico experto en radio/televisin para recibir ayuda. Adaptador inalmbrico, termostatos y sensor exterior Para cumplir con los lmites de exposicin RF que establecen la FCC y Industry Canada para la poblacin en general/exposicin no controlada, la o las antenas usadas para estos trans-
misores deben instalarse a una distancia de separacin de, al menos, 20 cm de todas las per-
sonas, y no deben colocarse ni utilizarse junto con otra antena o transmisor. Control remoto Este transmisor porttil y su antena cumplen con los lmites de exposicin RF que establecen la FCC y Industry Canada para la poblacin en general/exposicin no controlada. Declaracin de Industry Canada conforme a la Seccin 4.0 de RSP-100 El trmino IC: antes de la certificacin/el No. de registro solo significa que se cumplieron las especificaciones tcnicas de Industry Canada. Seccin 7.1.5 de RSS-GEN El funcionamiento est sujeto a las dos condiciones siguientes:
1 Este dispositivo no debe causar interferencia. 2 Este dispositivo deber aceptar cualquier interferencia, incluso la interferencia que pudiese causar el funcionamiento no deseado del dispositivo. 30 Guide dinstallation du systme Systme sans fil RedLINK avec tableau TrueZONE et adaptateur sans fil Espaol: vea la pgina 16 Franais : voir la page 31 Pour la commande sans fil des tableaux TrueZONE.
(Voir linformation sur le tableau de zonage pour connatre le nombre dtages de chauffage-refroidissement.) Guide dinstallation pour :
Thermostat sans fil FocusPRO
Tlcommande sans fil
Capteur dair extrieur sans fil COUPER LALIMENTATION LECTRIQUE AVANT DEFFECTUER LE RACCORDE-
MENT. Peut provoquer des chocs lectriques ou endommager le matriel. AVIS SUR LE MERCURE : Si le nouveau thermostat remplace un ancien rgulateur contenant un contact mercure, ne pas mettre lancien rgulateur aux poubelles. Communiquer avec le service local de cueillette des dchets pour obtenir de linformation sur le recyclage ou sur la bonne faon de disposer dun ancien rgulateur contenant un contact mercure. Doit tre install par un technicien dexprience ayant reu la formation pertinente. Lire attentivement les instructions. Le fait de ne pas les suivre risque dendommager le produit ou de constituer un danger. Marque de commence enregistre aux tats-Unis. Copyright 2008 Honeywell International Inc. Tous droits rservs. RedLINK Installation Guide (TrueZONE) Installation du systme en un coup doeil Thermostat Thermostat Capteur dair extrieur Matriel de CVCA Adaptateur sans fil Tableau TrueZONE Tlcommande Installation Le prsent document porte sur la connexion et linstallation de thermostats FocusPRO et daccessoires REDLINK sans fil au sein dune application TrueZONE. Avant de commencer, il faut installer, raccorder et configurer le tableau TrueZONE et ladaptateur sans fil (voir le Guide dinstallation TrueZone), puis suivre les tapes ci-dessous. 1 2 3 4 5 Configurer le tableau TrueZONE avant de commencer Insertion des piles dans lappareil sans fil ....................Page 33 Relier tous les appareils au rseau sans fil............Pages 33-35 Quitter la configuration des appareils sans fil ..............Page 36 Personnaliser (configuration par linstallateur) ......Pages 36-40 Installation du thermostat et du capteur extrieur........Page 41 Pour remplacer les composants du systme au besoin, voir la page 43 Sil y a plus dun module dinterface avec le matriel (EIM) : Les thermostats sont lis des modules dinterface particuliers. Les accessoires en option doivent tre lis chaque EIM sparment. 32 Espaol: vea la pgina 16 Franais : voir la page 31 1 Insertion des piles dans lappareil sans fil Une fois le raccordement du systme termin et le tableau TrueZONE configur RF, installer les piles dans tous les dispositifs. Sassurer quelles sont installes correctement (Voir illustration ci-dessous). Thermostat Insrer 2 piles AA neuves Thermostats programmables seulement Insrer laide-mmoire Tlcommande (optionnelle) Capteur dair extrieur (optionnel) Insrer 3 piles AA neuves Insrer 2 piles au lithium AA neuves 2 Relier tous les appareils au rseau sans fil Appuyer sur CONNECT Sassurer que le voyant vert Connected de ladaptateur sans fil clignote. Si le voyant cesse de clignoter avant que tous les appareils soient relis, appuyer nouveau sur le bouton CONNECT. Le voyant dtat cesse de clignoter aprs 15 minutes dinactivit. Appuyer sur le bouton CONNECT nouveau au besoin. Si le voyant ne clignote pas, il se pourrait quun autre EIM/adaptateur sans fil soit en mode de configuration dun appareil sans fil. Quitter le mode de configuration lautre EIM ou adaptateur sans fil. suivre >>
33 RedLINK Installation Guide (TrueZONE) Relier le thermostat au rseau sans fil Numro de zone Wireless Setup0 1 Appuyer sur ou pour rgler un numro de zone pour ce thermostat (1 4), puis appuyer sur NEXT. Back Next Nom de zone Wireless Setup 36 52 Appuyer sur ou pour modifier le nom ou lemplacement de cette zone, puis appuyer sur NEXT. Exemple : 31 = Living Room Back Next Voir la liste complte des zones la page 38. Wireless Setup Wireless Setup Appuyer sur CONNECT pour tablir un lien avec le rseau sans fil. Si lcran affiche E1, voir les codes derreur la page 42. Back Connect Wireless Setup Wireless Setup Connected Done Aprs une courte pause, lcran de confir-
mation gauche devrait apparatre, indi-
quant que la connexion sans fil a bien t tablie. Appuyer sur DONE pour revenir lcran daccueil. 34 Relier la tlcommande au rseau sans fil (optionnel) Espaol: vea la pgina 16 Franais : voir la page 31 CONNECT WIRELESS SETUP Appuyer pour relier un autre EIM Appuyer pour enregistrer et quitter YES NO CONNECT MORE?
1 Sassurer que le voyant Connected de ladaptateur sans fil clignote. 2 Appuyer sur CONNECT de la tlcom-
mande. Il y a aura un court dlai pen-
dant que la tlcommande recherche le signal du rseau sans fil. 3 Lorsque lcran affiche Connected, appuyer sur DONE. 4 Appuyer sur NO lcran suivant pour sauvegarder la configuration et quitter. (Ou appuyer sur YES et rpter les tapes 1 4 pour relier un autre tableau de zonage.) Si lcran affiche E1, voir les codes derreur la page 42. Le raccordement au rseau sans fil peut prendre fin automatiquement aprs 30 minutes dinactivit sur les touches. Pour recommencer, appuyer sur lespace vierge (ou sur la flche, selon le cas) dans le coin infrieur droit de lcran jusqu ce que lcran change (au bout denviron 3 secondes). Relier le capteur dair extrieur au rseau sans fil (optionnel) Appuyer et le relcher 1 Sassurer que le voyant Connected du EIM clignote (voir la page 43). 2 Appuyer sur le bouton CONNECT larrire du capteur. 3 Observer le thermostat pour vrifier que le capteur dair extrieur fonc-
tionne. Aprs environ 15 secondes, le thermostat devrait afficher la tem-
prature et lhumidit extrieures.
(Sil y a plus dun EIM installer, rpter les tapes 1 3 pour chacun.) 35 RedLINK Installation Guide (TrueZONE) 3 Quitter la configuration du rseau sans fil Appuyer sur CONNECT au EIM pour quitter la configuration du rseau sans fil
(le voyant devrait cesser de clignoter). Remarque : Le EIM quittera automatiquement la configuration du rseau sans fil aprs 15 minutes dactivit. Remarque : Lors de linstallation de plus dun thermostat et plus dun EIM, il faut quitter la configuration du rseau sans fil avant linstallation dun thermostat et dun EIM additionnels. 4 Personnalisation (mode de configuration par linstallateur) Suivre les tapes ci-dessous pour commencer la configuration. chaque cran de fonction, appuyer sur ou pour obtenir le rglage dsir, puis appuyer sur NEXT pour passer lcran de fonction suivant. Voir les tableaux aux pages 39 40 pour obtenir une description de chacune des fonctions. 0 1 Done Back Next Appuyer sur ou pour modifier le rglage (voir les pages 39 40). FAN Appuyer les boutons FAN et jusqu ce que laffichage change (au bout denviron 3 secondes). Fonction Rglage 1 0 Done Back Next Appuyer sur NEXT pour faire afficher lcran de fonction suivant. Appuyer sur DONE pour enregistrer et quitter. 36 Espaol: vea la pgina 16 Franais : voir la page 31 Tableaux de configuration par linstallateur Fonctions Options (rglages de lusine en gras) 0 1 2 3 5 6 7 8 9 10 12 13 14 Numro de zone Type de systme 0 Pas de zonage (un seul thermostat employ avec le EIM THM5320R
[Options : slectionner la zone 1, 2, 3 ou 4]
0 Chauffage-refroidissement classique 1 chaud/1 froid 1 Thermopompe 1 chaud/1 froid (sans chauffage auxiliaire) 2 Chauffage seulement (y compris Srie 20) 3 Chauffage seulement avec ventilateur 4 Refroidissement seulement 5 Thermopompe 2 chaud/1 froid 6 Chauffage-refroidissement classique 2 chaud/2 froid 7 Chauffage-refroidissement classique 2 chaud/1 froidl 8 Chauffage-refroidissement classique 1 chaud/2 froid 9 Thermopompe 2 chaud/2 froid 10 Thermopompe 3 chaud/2 froid Vanne dinversion
(borne O/B) 0 La borne O/B fait passer la vanne au mode de refroidissement 1 La borne O/B fait passer la vanne au mode de chauffage Ventilateur
(chauffage classique) 0 Chauffage au gaz/mazout (ventilateur command par le systme) 1 Chauffage llectricit (ventilateur command par le thermostat) Cycles de chauffage
(tage 1) CPH=
cycles par heure Cycles de chauffage
(tage 2) (CPH) Cycles de chauffage
(tage 3) (CPH) 5 Chauffage au gaz ou au mazout (< 90 % defficacit) 1 Systmes vapeur ou gravit 3 Systmes eau chaude et appareils de chauffage > 90 % defficacit 9 Appareils de chauffage lectriques
[Options de cycles par heure : 1 12]
5 Chauffage au gaz ou au mazout (< 90 % defficacit) 1 Systmes vapeur ou gravit 3 Systmes eau chaude et appareils de chauffage > 90 % defficacit 9 Appareils de chauffage lectriques
[Options de cycles par heure : 1 12]
5 Chauffage au gaz ou au mazout (< 90 % defficacit) 1 Systmes vapeur ou gravit 3 Systmes eau chaude et appareils de chauffage > 90 % defficacit 9 Appareils de chauffage lectriques
[Options de cycles par heure : 1 12]
Cycles de chauffage durgence (CPH) 9 Appareils de chauffage lectriques
[Options de cycles par heure : 1 12]
Cycles de com-
presseur (tage 1) Cycles de com-
presseur (tage 2) 3 Cycles par heure recommands
[Options de cycles par heure : 1 6]
3 Cycles par heure recommands
[Options de cycles par heure : 1 6]
Commutation chaud-
froid manuelle/auto 0 Manuel (Options de lutilisateur : Heat/Cool/Off) 1 Automatique (Options de lutilisateur : Heat/Cool/Auto/Off) Adaptive Intelligent Recovery Sapplique seulement au modle TH6320 0 larrt **
1 En marche Affichage de la temprature 0 Fahrenheit 1 Celsius
** Voir la page 41 37 RedLINK Installation Guide (TrueZONE) Tableaux de configuration par linstallateur Fonctions Options (rglages de lusine en gras) 15 Temps darrt du compresseur (min.) 16 Type de programme 5 5 minutes (les mots Heat On/Cool On clignotent lcran )
[Options : 0 4 minutes]
Sapplique seulement au modle TH6320 0 Horaire de semaine/fin de semaine 1 Horaire de semaine/samedi/dimanche 26 27 28 32 33 35 36 Rgulation du chauffage auxiliaire Sapplique seulement au modle TH5320 0 Confort **
1 conomique Point de consigne de chauffage (max.) Point de consigne de refroidissement (min.) 90 Point de consigne de chauffage maximal de 90 F (32 C)
[Options : 40 90 F (4,5 32 C)]
50 Point de consigne de refroidissement minimal de 50 F (10 C)
[Options : 50 99 F (10 37 C)]
cart avec la temp. affiche (intrieure) 0 Le thermostat affiche la temprature relle
[Options : -3 +3 F dcart (-1.5 +1.5 C)]
cart avec la temp. affiche (extrieure) 0 Le thermostat affiche la temprature relle
[Options : -5 +5 F dcart (-2.5 +2.5 C)]
cart avec lhumidit affiche
(extrieure) Nom de la zone 3 Le thermostat affiche lhumidit relle
[Options : 0 = -15 %, 1 = -10%, 2 = -5 %, 4 = 5 %, 5 = 10 %, 6 = 15 % dcart]
52 Thermostat 1 Basement 2 Bathroom 3 Bathroom 1 4 Bathroom 2 5 Bathroom 3 6 Bedroom 7 Bedroom 1 8 Bedroom 2 9 Bedroom 3 10 Bedroom 4 11 Boat House 12 Bonus Room 13 Computer Room 14 Den 15 Dining Room 16 Exercise Room 17 Family Room 18 Fireplace 19 Foyer 20 Game Room 21 Garage 22 Great Room 23 Guest Room 24 Gym 25 Kids Room 26 Kitchen 27 Kitchen 1 28 Kitchen 2 29 Laundry Room 30 Library 31 Living Room 32 Lower Level 33 Master Bath 34 Master Bed 35 Media Room 36 Music Room 37 Nursery 38 Office 39 Office 1 40 Office 2 41 Pantry 42 Play Room 43 Pool Room 44 Porch 45 Rec Room 46 Sewing Room 47 Spa 48 Storage Room 49 Studio 50 Sun Room 51 Theater 52 Thermostat 53 Upper Level 54 Utility Room 55 Walk In Closet 56 Wine Cellar 57 Workshop 39 Configuration sans fil 90 RARMER 0 Dbrancher le thermostat du rseau sans fil 1 Thermostat reli au rseau sans fil 0 Pas de rarmement 1 Rarmer les options de linstallateur et le programme aux rglages de lusine
** Voir la page 41 38 Espaol: vea la pgina 16 Franais : voir la page 31 Fonctions spciales Adaptive Intelligent Recovery (Configuration de la fonction 13) : Permet au thermostat dapprendre combien de temps il faut au systme de chauffage ou de refroidissement pour atteindre la temprature souhaite pour que la temprature dsire soit atteinte lheure prvue. Protection du compresseur (Configuration de la fonction 15) : Cette fonction oblige le compresseur attendre quelques minutes avant de redmarrer . Pendant ce temps, les mots HeatOn/Cool On clignotent lcran. Confort/conomie (Configuration de la fonction 26) :
En mode confort, le chauffage auxiliaire ragira rapidement pour atteindre le point de consigne de temprature. En mode conomie, le systme attendra plus longtemps. Le chauffage auxili-
aire ne sera activ que si le point de consigne nest pas atteint au bout dun temps raisonnable. 39 RedLINK Installation Guide (TrueZONE) Test du systme Suivre les tapes ci-dessous pour vrifier le bon fonctionnement du systme. Numro de test du systme tat du systme 02 0 Done Back Next Appuyer sur les boutons et jusqu ce que laffichage change (au bout denviron 3 secondes). Appuyer sur ou pour vrifier ltat du systme Appuyer sur NEXT pour passer au test suivant Appuyer sur DONE pour mettre fin la vrification Test du systme tat du systme 02 Test du rseau sans fil 0 larrt 1 Vrifier le signal radio (aprs une courte pause, lcran affiche 1-10 pour indiquer la force du signal; 5 ou plus recommand) 10 Systme de chauffage 0 Le systme de chauffage et le ventilateur se mettent larrt 1 Le systme de chauffage se met en marche (tage 1) 2 Le systme de chauffage se met en marche (tage 2) 3 Le systme de chauffage se met en marche (tage 3) 20 30 Systme de chauffage durgence 0 Le systme de chauffage et le ventilateur se mettent larrt 1 Le systme de chauffage et le ventilateur se mettent en marche Systme de refroidissement 0 Le compresseur et le ventilateur se mettent larrt 1 Le compresseur et le ventilateur se mettent en marche 2 compresseur se met en marche (tage 2) 40 Ventilateur 0 Le ventilateur se met larrt 1 Le ventilateur se met en marche 70 Information sur le thermostat
(pour rfrence seulement) 71 Numro de rvision du logiciel (rvisions majeures) 72 Numro de rvision du logiciel (rvisions mineures) 73 Code didentification de la configuration (majeure) 74 Code didentification de la configuration (mineure) 75 Code de date de la configuration la fabrication (semaine) 76 Code de date de la configuration la fabrication (anne) MISE EN GARDE : RISQUE DE DOMMAGE MATRIEL. Le systme ne tient pas compte du temps darrt minimal du compresseur pendant le test par linstallateur. Pour viter dendommager le matriel, viter les cycles de fonctionnement trop rapides du compresseur. 40 Espaol: vea la pgina 16 Franais : voir la page 31 5 Installer le thermostat et le capteur extrieur 3/16 po si le mur est en placopltre 7/32 po si le mur est en pltre Vis de fixation Cheville dancrage Dtacher la plaque murale Plaque murale Capteur extrieur (optionnel) Installer le capteur sur un mur extrieur la verticale, au moins 6 pouces (15 cm) de tout surplomb. Choisir un emplacement o le capteur sera labri des rayons du soleil. Fixer fermement le capteur sur le support, en mettant le dos de lappareil contre le mur. Appuyer et le relcher Pour vrifier lemplacement avant linstallation :
Revenir lcran daccueil du thermostat, tenir le capteur lendroit o lon souhaite linstaller et appuyer sur le bouton CONNECT. Si le capteur fonctionne correctement, le thermostat passera laffichage de la temprature et de lhumidit extrieures. 41 RedLINK Installation Guide (TrueZONE) Vrifier la configuration Lorsque la configuration du rseau sans fil est termine, sassurer que le voyant vert Connect reste allum ladaptateur sans fil (voir ci-dessous), puis suivre les tapes de la section Vrification du guide dinstallation TrueZONE pour vrifier le bon fonctionnement. Voyant dtat du rseau sans fil
Allum vert en continu : ladaptateur sans fil fonctionne correctement et communique avec les appareils sans fil.
Vert clignotant : tablit le lien avec le rseau sans fil (le voyant clignote pen-
dant 15 minutes aprs que lutilisateur ait appuy sur le bouton CONNECT).
Allum rouge en continu : Problme de communication. Vrifier ladaptateur sans fil et les autres appareils sans fil. Codes derreur (thermostat et tlcommande) Si lcran affiche E1 au cours de linstallation, vrifier le numro du code derreur
(dans la partie droite de lcran) :
29 30 31 34 38 Tentative de configuration dappareils incompatibles. Vrifier si le numro du thermostat de zone correspond au numro attribu au tableau de zonage. Vrifier si le numro de zone est configur au tableau de zonage en tant que thermostat radiofrquences. Signal trop faible. Dplacer lappareil sans fil un autre endroit et essayer nouveau. Sassurer que les voyants Connect de ladaptateur sans fil clignotent et que le thermostat ou la tlcommande sont 2 pieds et plus de ladaptateur sans fil. 42 Espaol: vea la pgina 16 Franais : voir la page 31 Remplacement des composants du systme Thermostat Pour remplacer un thermostat, insrer des piles neuves dans le nouvel appareil et suivre les tapes dcrites la page 34 pour le relier au rseau sans fil. Au besoin, modifier les paramtres (voir les tableaux aux pages 37 39). Tlcommande et capteur extrieur Pour remplacer une tlcommande ou un capteur dair extrieur, insrer des piles neuves dans le nouvel appareil et suivre les tapes dcrites la page 5 pour le relier au rseau sans fil. Tableau TrueZONE et adaptateur sans fil Aprs linstallation dun nouveau tableau de zonage ou adaptateur sans fil, il faut rarmer le thermostat pour quil puisse communiquer avec le nouveau matriel, selon la description qui suit. Au thermostat :
1 Appuyer pendant environ 3 secondes sur les boutons FAN et . 2 Appuyer sur le bouton BACK deux fois pour afficher la fonction 39
(configuration du rseau sans fil). 3 Appuyer sur pour faire passer le paramtre 39 au rglage 0
(se dconnecter de lancien matriel). 4 Suivre les tapes la page 34 pour connecter le nouvel appareil au rseau. la tlcommande :
1 Appuyer environ 3 secondes sur lespace vierge (ou la flche, selon le cas) dans le coin infrieur droit de lcran jusqu ce que laffichage change. 2 Appuyer sur le bouton REMOVE, puis sur YES pour dconnecter lancien matriel. 3 Suivre les tapes la page 35 pour connecter le nouvel appareil au rseau. Appuyer sur le bouton environ 3 secondes 43 RedLINK Installation Guide (TrueZONE) Caractristiques techniques et pices de rechange Gamme de temprature ambiante de service Thermostat : 32 120 F (0 48,9 C) Tlcommande : 32 120 F (0 48,9 C) Adaptateur sans fil : -40 165 F (-40 73,9 C) Capteur dair extrieur : -40 140 F (-40 60 C) Humidit relative de service Thermostat : 5 % 90 % (sans condensation) Tlcommande : 5 % 90 % (sans condensation) Adaptateur sans fil : 5 % 95 % (sans condensation) Capteur dair extrieur : 0 % to 100 % (condensation) Encombrement (hauteur, largeur, profondeur) Thermostat : 91 x 147 x 38 mm (3-9/16 x 5-13/16 x 1-1/2 po) Adaptateur sans fil : 206 x 203 x 47 mm (8-1/8 x 8 x 1-7/8 po) Capteur dair extrieur : 127 x 89 x 43 mm (5 x 3-1/2 x 1-11/16 po) Accessoires/Pices de rechange Article Numro de la pice Adaptateur sans fil Thermostat sans fil FocusPRO (programmable) Thermostat sans fil FocusPRO (non programmable) Tlcommande Capteur dair extrieur Porte-piles Plaque de recouvrement (sert masquer les marques laisses par les anciens thermostats THM4000R1000 TH6320R1004 TH5320R1002 REM5000R1001 C7089R1013 50007072-001 50002883-001 44 Espaol: vea la pgina 16 Franais : voir la page 31 Information sur la rglementation Dclaration de conformit la FCC (partie 15,19) (tats-Unis seulement) Cet appareil est conforme la Partie 15 des rgles de la FCC. Le fonctionnement de ce sys-
tme est assorti aux deux conditions suivantes :
1 Lappareil ne peut causer dinterfrences nuisibles, et 2 Lappareil doit accepter les interfrences reues, y compris celles qui pourraient nuire son fonctionnement. Avis de la FCC (partie 15,21) (tats-Unis seulement) Toute modification qui nest pas autorise expressment par la partie responsable de la con-
formit de lappareil aux rgles en vigueur pourrait rendre lutilisateur inapte faire fonctionner le matriel. Dclaration sur linterfrence selon la FCC (partie 15,105 (b)) (tats-Unis seulement) Ce dispositif a t test et dclar conforme aux normes spcifies dans la partie 15 des rglements de la FCC (Federal Communications Commission) concernant les dispositifs numriques de classe B. Ces limites sont conue pour offrir une protection raisonnable contre les interfrences nocives pouvant survenir lorsque le produit est utilis dans un environnement rsidentiel. Ce dispositif produit, utilise et met de lnergie radiolectrique qui peut perturber les communications radio sil nest pas install et utilis conformment aux instructions du fab-
ricant. Toutefois, rien ne garantit quil ny aura pas dinterfrences dans une installation don-
ne. Si lappareil produit des interfrences qui nuisent la rception radio ou tl, ce quon peut dterminer en mettant lappareil en service et hors service, lutilisateur est invit corriger la situation de lune ou lautre des faons suivantes :
Rorienter ou dplacer lantenne de rception.
Augmenter lespace qui spare lappareil du rcepteur.
Brancher lappareil une prise faisant partie dun circuit diffrent de celui du rcepteur.
Consulter un dtaillant ou technicien radio-tl dexprience pour obtenir de laide. Adaptateur sans fil, thermostats et capteur extrieur Pour tre conformes aux limites dexposition aux radiofrquences tablies par la FCC et Industrie Canada pour le grand public/lexposition non contrle, la ou les antennes employes par le transmetteur doivent tre installes au moins 20 cm de distance de toute personne et ne peuvent tre situes au mme endroit quune autre antenne ou un autre trans-
metteur ou fonctionner conjointement avec une autre antenne ou un autre transmetteur. Tlcommande Le transmetteur portatif et son antenne sont conformes aux limites dexposition aux radiofrquences tablies par la FCC et Industrie Canada pour le grand public/lexposition non contrle. Dclaration dIndustrie Canada selon larticle 4.0 de la PNR-100 Les lettres IC devant le numro dinscription/homologation signifient que lappareil respecte les normes techniques dIndustrie Canada. Article 7.1.5 de CNR-GEN Le fonctionnement de ce systme est assorti aux deux conditions suivantes :
1 Lappareil ne peut causer dinterfrences nuisibles, et 2 Lappareil doit accepter les interfrences reues, y compris celles qui pourraient nuire son fonctionnement. 45 Need Help?
For assistance with this product please visit http://customer.honeywell.com or call Honeywell Customer Care toll-free at 1-800-828-8367 Necesita ayuda?
Consulte sobre este producto en http://customer.honeywell.com o llamando sin cargo a atencin al cliente de Honeywell 1-800-828-8367 Vous faut-il de laide ?
Pour obtenir de lassistance concernant ce produit, visitez http://customer.honeywell.com ou appelez gratuitement lassistance client dHoneywell au 1-800-828-8367 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://yourhome.honeywell.com Honeywell Limited-Honeywell Limite 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10%
post-consumer paper fibers. 69-2090EFS-01 06-2008 2008 Honeywell International Inc. U.S. Registered Trademark.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2008-08-19 | 903 ~ 926.4 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2008-08-19
|
||||
1 | Applicant's complete, legal business name |
Ademco Inc
|
||||
1 | FCC Registration Number (FRN) |
0004788345
|
||||
1 | Physical Address |
1985 Douglas Drive
|
||||
1 |
Golden Valley, Minnesota 55422-3922
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@curtis-straus.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
HS9
|
||||
1 | Equipment Product Code |
TH6320R01
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
P******** W********
|
||||
1 | Title |
Sr. Compliance Engr
|
||||
1 | Telephone Number |
763-9********
|
||||
1 | Fax Number |
763-9********
|
||||
1 |
P******@Honeywell.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Thermostat | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | Yes | ||||
1 | Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
LS Research, LLC
|
||||
1 | Name |
R**** U****
|
||||
1 | Telephone Number |
262-3********
|
||||
1 | Fax Number |
262 3********
|
||||
1 |
r******@lsr.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 20 | 903.00000000 | 926.40000000 | 0.0130000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC