ION-U Optical Remote Unit ION-U L 7/8/85/17/19 User's Manual MF0147A0A DISCLAIMER:
This document has been developed by CommScope, and is intended for the use of its customers and customer support personnel. The information in this document is subject to change without notice. While every effort has been made to eliminate errors, CommScope disclaims liability for any difficulties arising from the interpretation of the information contained herein. The information contained herein does not claim to cover all details or variations in equipment, nor to provide for every possible incident to be met in connection with installation, operation, or maintenance. This document describes the performance of the product under the defined operational conditions and does not cover the performance under adverse or disturbed conditions. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchasers purposes, contact CommScope. CommScope reserves the right to change all hardware and software characteristics without notice. COPYRIGHT:
Copyright 2013 CommScope Inc. All Rights Reserved. This document is protected by copyright. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical photocopying, recording, or otherwise without the prior written permission of CommScope. TRADEMARKS All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. Andrew Wireless Systems GmbH, 04-February-2013 Page 2 Users Manual for ION-U 7/8/85/17/19 Table of contents TABLE OF CONTENTS 1. GENERAL 1.1. 1.2. USED ABBREVIATIONS HEALTH AND SAFETY WARNINGS ABOUT COMMSCOPE 1.3. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT INTRODUCTION 1.4. 1.5. PURPOSE THE ION-U L 7/8/85/17/19 REMOTE UNIT 2. FUNCTIONAL DESCRIPTION 2.1. 2.2. SISO AND MIMO OPERATION ION-U 7/8/85/17/19 PORTS 3. COMMISSIONING 3.1. 3.1.1. 3.1.2. 3.2. 3.2.1. 3.2.2. 3.2.3. 3.2.4. 3.2.5. 3.2.6. 3.2.7. 3.2.8. 3.2.9. 3.3. 3.3.1. 3.3.2. MECHANICAL INSTALLATION General Wall-Mounting Procedure ELECTRICAL INSTALLATION General Connections Grounding (Earthing) Mains Power Connection Antenna Connection Expansion Ports Connections Alarm Port Pwr/Ctrl Port Control Connector RS-232 - Local Interface OPTICAL-FIBER-CABLE CONNECTION - RULES Optical cable installation Commissioning 4. ALARMS 4.1. 4.2. BITE AND ALARMS HANDLING OF ALARMS MF0147A0A 7 7 8 11 12 15 15 15 17 17 18 20 20 20 21 24 24 26 28 29 31 32 33 33 34 35 37 39 40 40 40 Page 3 4.3. 4.4. 4.5. STATUS LED ALARMS EXTERNAL ALARM INPUTS TROUBLESHOOTING 5. MAINTENANCE 5.1. 5.2. GENERAL RU POWER SUPPLY REPLACEMENT 6. APPENDIX 6.1. 6.2. 6.3. 6.4. 6.5. ILLUSTRATIONS ELECTRICAL SPECIFICATIONS ENVIRONMENTAL AND SAFETY SPECIFICATIONS MECHANICAL SPECIFICATIONS SPARE PARTS INDEX 7. Table of contents 41 42 43 44 44 45 49 49 50 50 50 51 52 Page 4 Users Manual for ION-U 7/8/85/17/19 figures and tables FIGURES AND TABLES figure 3-2 Remote unit, SISO .................................................................................... 17 figure 3-3 Remote unit, MIMO Two units paired ....................................................... 17 figure 3-4 RU Connectors and Status LED ............................................................... 18 figure 4-1 Wall-mounting bracket .............................................................................. 21 figure 4-2 RU threaded pins ...................................................................................... 21 figure 4-3 RU placed on wall mounting bracket ........................................................ 22 figure 4-4 Install M6x12 screws and washers ........................................................... 22 figure 4-5 Attach M6 nut to threaded pins ................................................................. 23 figure 4-6 Completed SISO RU Mount ..................................................................... 23 figure 4-9 ION-U L 7/8/85/17/19 Connectors ............................................................ 26 figure 4-10 Grounding bolt ........................................................................................ 28 figure 4-11 Grounding bolt, schematic view .............................................................. 28 figure 4-12 AC power cable ...................................................................................... 29 figure 4-13 DC power cable ...................................................................................... 29 figure 4-14 Vdc/100 power cable .............................................................................. 30 figure 4-15 Connect Mains plug ................................................................................ 31 figure 4-16 N-type antenna connection ..................................................................... 32 figure 4-17 Expansion ports ...................................................................................... 33 figure 4-18 Alarm Connector ..................................................................................... 33 figure 4-19 Pwr/Ctrl Connector ................................................................................. 34 figure 4-20 RS-232 connector ................................................................................... 34 figure 4-21 Remove optics cover .............................................................................. 37 figure 4-22 Remove sealing nut ................................................................................ 37 figure 4-23 Remove split-seal ................................................................................... 37 figure 4-24 Insert fiber optic cables through sealing nut ........................................... 38 figure 4-25 Insert cables through clamp ring............................................................. 38 figure 4-26 Place cables into split-seal ..................................................................... 38 figure 4-27 Press split-seal into opening ................................................................... 39 figure 4-28 Tighten sealing nut ................................................................................. 39 figure 5-1 Alarm triggering ........................................................................................ 40 figure 6-1 Disconnect Mains power .......................................................................... 45 figure 6-2 RU power supply location ......................................................................... 45 figure 6-3 8 RU power supply screws ....................................................................... 46 figure 6-4 RU power supply with cables ................................................................... 46 figure 6-5 RU power supply input cable .................................................................... 46 figure 6-6 RU power supply output cable .................................................................. 47 figure 6-7 Ru with power supply removed ................................................................ 47 figure 6-8 Ru with replacement power supply ........................................................... 47 figure 6-9 Ru insert power supply ............................................................................. 48 figure 6-10 Reconnect Mains power ......................................................................... 48 figure 7-1 Installation drawing ................................................................................... 49 MF0147A0A Page 5 figures and tables table 1-1 List of international contact addresses ....................................................... 14 table 4-1 Specified torques ....................................................................................... 20 table 4-2: ION-U L 7/8/85/17/19 Connectors ............................................................ 27 table 4-3 AC power cable ......................................................................................... 29 table 4-4 DC power cable ......................................................................................... 29 table 4-5 Vdc/100 power cable ................................................................................. 30 table 4-6 Alarm Connector ........................................................................................ 33 table 4-7 Pwr/Ctrl Connector .................................................................................... 34 table 4-8 RS-232 connector, pin assignment ............................................................ 34 table 5-1 Status LED alarms ..................................................................................... 42 Page 6 Users Manual for ION-U 7/8/85/17/19 1 General 1. General 1.1. Used Abbreviations 3GPP AC/DC AIMOS ALC BITE BTS CE CD CPD DL DoC EDGE EN EP ESD ETS EU GSM GND GUI ICP3 ID No ION IP ISO LED LMT LTE MIMO MS MU NF OTRx PDU PG PIM Pin Pout R&TTE Rev RF RU RX SNMP TS TX UL UMTS UPS VSWR WCDMA WDM 3rd Generation Partnership Project Alternating current / Direct Current Andrew Integrated Management and Operating System Automatic Level Control Built-In Test Equipment Base Transceiver Station
"Conformit Europenne" ("European Conformity") Compact Disk Channel Power Detection Downlink Declaration of Conformity Enhanced Data Rates for GSM Evolution European Norm Extension Port Electrostatic Discharge European Telecommunication Standard Extension Unit Global System for Mobile Communication Ground (Earth) Graphical User Interface Intercept Point 3rd order Identification Number Intelligent Optical Network Ingress Protection International Organization for Standardization Light Emitting Diode Local Maintenance Terminal Long Term Evolution Multiple Input Multiple Output Mobile Station Main Unit Noise Figure Optical Transceiver = SRMU (Subrack Master Unit) Power Distribution Unit Packing Gland Passive Intermodulation Input power Output power Radio & Telecommunications Terminal Equipment Revision Radio Frequency Remote Unit Receiver Simple Network Management Protocol Technical Specification Transmitter Uplink Universal Mobile Telecommunication System Uninterruptible Power Supply Voltage Standing Wave Ratio Wideband Code Division Multiple Access Wavelength Division Multiplex MF0147A0A Page 7 1.2. Health and Safety Warnings 1 General 1. Danger: Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments. 3. Danger: Before opening the unit, disconnect mains power. 4. Danger: Due to power dissipation, the remote unit may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. 5. Warning: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. 6. Warning: It is the responsibility of the network provider to implement prevention measures to avoid health hazards associated with radiation from the antenna(s) connected to the unit. 7. Warning: Make sure, access is restricted to qualified personnel. 8. Warning: Only licence holders for the respective frequency range are allowed to operate this unit. 9. Warning: Make sure the repeater settings are correct for the intended use (refer to the manufacturer product information) and regulatory requirements are met. 10. Warning: Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer. This could cause fires, electric shock, or other injuries. 11. Warning: For installations, which have to comply with FCC RF exposure requirements, the antenna selection and installation must be completed in a way to ensure compliance with those FCC requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss between the repeater and antenna, the minimum distance D to be maintained between the antenna location and human beings is calculated according to this formula:
where P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in addition to the antenna gain minus the loss between the repeater and the antenna. Page 8 Users Manual for ION-U 7/8/85/17/19
]/[][][24cmmWmWcmPDPD 1 General PD (mW/cm) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general population / uncontrolled exposures which is o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz o 1 for frequencies from 1500MHz to 100.000MHz RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 12. Warning: For installations which have to comply with Europe an EN50385 exposure compliance requirements, the following Power Density limits/guidelines
(mW/cm) according to ICNIRP are valid:
0.2 for frequencies from 10 MHz to 400 MHz o o F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz o 1 for frequencies from 2 GHz to 300 GHz 13. Caution: Keep operating instructions within easy reach and make them available to all users. 14. Caution: Corresponding local particularities and regulations must be observed. For national deviations, please refer to the respective documents included in the manual CD that is delivered with the unit. 15. Caution: Although the remote unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the repeaters antenna connectors for protection against atmospheric discharge. 16. Caution: ESD precautions must be observed! Before commencing maintenance work, use the available grounding (earthing) system to connect ESD protection measures. 17. Note: For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 18. Note: This unit complies with European standard EN60950. MF0147A0A Page 9 1 General Equipment Symbols Used Please observe the meanings of the following symbols used in our equipment:
Symbol Compliance Meaning
---
Alert sign to R&TTE Symbol Indicates conformity with the R&TTE directive 1999/5/EC certified by the notified body no. 0700. Page 10 Users Manual for ION-U 7/8/85/17/19 1 General About CommScope CommScope is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Part of the CommScope portfolio are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization. CommScope has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world. Andrew Wireless Systems GmbH based in Buchdorf/ Germany, which is part of CommScope, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage and capacity solution for wireless networks in both indoor installations and outdoor environments, e.g. tunnels, subways, in-trains, airport buildings, stadiums, skyscrapers, shopping malls, hotels and conference rooms. Andrew Wireless Systems GmbH operates a quality management system in compliance with the requirements of ISO 9001 and TL 9000. All equipment is manufactured using highly reliable material. To maintain highest quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation. This product meets the requirements of the R&TTE directive and the Declaration of Conformity (DoC) itself. A current version of the CE DoC is included in this manual CD delivered *. Any updated version of the DoC is available upon request from the local sales offices or directly from CommScope via the local Customer Support at one of the addresses listed in the following chapter. According to the DoC, our "CE"-marked equipment can be used in all member states of the European Union. Note: Exceptions of and national deviations from this intended use may be possible. To observe corresponding local particularities and regulations, please refer to the respective documents (also in national language) which are included in the manual CD delivered.
* In case the Declaration of Conformity (DoC) for the product was not included in the manual CD delivered, it is available upon request from the local sales offices or directly from CommScope at one of the addresses listed in the following chapter. To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions. For technical assistance and support, please also contact the local office or CommScope directly at one of the addresses listed in the following chapter. MF0147A0A Page 11 1 General 1.3. International Contact Addresses for Customer Support Canada CommScope Canada Mail 505 Consumers Road, Suite 803 Toronto M2J 4V8 Canada Phone
+1-905-878-3457 (Office)
+1-416-721-5058 (Cell) Americas:
United States Andrew LLC, A CommScope Company Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Phone +1-888-297-6433 Fax
+1-905-878-3297 Fax
+1-919-329-8950 E-mail Peter.Masih@commscope.com, wisupport.us@commscope.com Caribbean & South American Region
(CALA) E-mail wisupport.us@commscope.com Caribbean (CALA) & Central American Region CommScope Cabos do Brasil Ltda. CommScope Mexico S.A. de C.V. Mail CALA Tech Support for Distributed Coverage & Capacity Solutions
(DCCS) products:
Rua Guaporanga, 49 Praa Seca Rio de Janeiro RJ ZIP: 21320-180 Brazil Mail CALA Tech Support for Distributed Coverage & Capacity Solutions
(DCCS) products:
Av. Insurgentes Sur 688, Piso 6 Col. Del Valle, CP: 03100 Mexico City Mexico Phone
+1-815-546-7154 (Cell)
+55-15-9104-7722 (Office) Phone
+52-1-55-5419-5260 (Cell)
+52-55-1346-1900 (Office) Fax
+ 55-15-2102-4001 Fax
+52-55-1346-1901 E-mail wisupport@commscope.com E-mail wisupport@commscope.com APAC Countries:
China, India and Rest of Asia Australia & New Zealand Andrew International Corporation Andrew Corporation (Australia) Pty Ltd. Mail Room 915, 9/F Chevalier Commercial Centre 8 Wang Hoi Rd Kowloon Bay Hong Kong Phone
+852-3106-6100 Fax
+852-2751-7800 Mail Unit 1 153 Barry Road Campbellfield VIC 3061 Australia Phone +613-9300-7969 Fax
+613-9357-9110 E-mail wisupport.China@commscope.com E-mail wisupport.Australia@commscope.com Page 12 Users Manual for ION-U 7/8/85/17/19 1 General Mail Europe:
United Kingdom Scandinavia Andrew Wireless Systems UK Ltd Andrew Norway (AMNW) Unit 15, Ilex Building Mulberry Business Park Fishponds Road Wokingham Berkshire RG41 2GY England Mail P.O. Box 3066 Osloveien 10 Hoenefoss 3501 Norway Phone +44-1189-366-792 Fax
+44-1189-366-773 E-mail wisupport.uk@commscope.com Phone
+ 47 32-12-3530 Fax
+ 47 32-12-3531 E-mail wisupport@commscope.com Germany France Andrew Wireless Systems GmbH CommScope France Mail Industriering 10 86675 Buchdorf Germany Phone +49-9099-69-0 Fax
+49-9099-69-930 Mail Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie France Phone
+33-1 82 97 04 00 Fax
+33-1 47 89 45 25 E-mail wisupport@commscope.com E-mail wisupport@commscope.com Austria Switzerland Andrew Wireless Systems (Austria) GmbH CommScope Wireless Systems AG Mail Weglgasse 10 2320 Wien-Schwechat Austria Phone +43-1706-39-99-10 Fax
+43-1706-39-99-9 Mail Tiergartenweg 1 CH-4710 Balsthal Switzerland Phone
+41-62-386-1260 Fax
+41-62-386-1261 E-mail wisupport.austria@commscope.com E-mail wisupport.ch@commscope.com Italy Iberia Region - Spain & Portugal CommScope Italy S.r.l., Faenza, Italy Mail Via Mengolina, 20 48018 Faenza (RA) Italy Phone
+39-0546-697111 Fax
+39-0546-682768 Andrew Espaa S.A. A CommScope Company Avda. de Europa, 4 - 2 pta. Parque Empresarial de la Moraleja Alcobendas, Madrid 28108 Spain Mail Phone
+34-91-745-20 40 Fax
+34-91-661-87 02 E-mail wisupport.italia@commscope.com E-mail wisupport.iberia@commscope.com MF0147A0A Page 13 1 General Czech Republic CommScope Solutions Czech Republic C-Com, spol. s r.o U Moru 888 53006 Pardubice Czech Republic
+49 871 9659171 (Office)
+49 171 4001166 (Mobile) Mail Phone Fax
+49 871 9659172 E-mail wisupport@commscope.com Africa & Middle East:
Middle East & North Africa South Africa CommScope Solutions International Inc. Andrew Wireless Solutions Africa (PTY)
(Branch) LTD Mail PO Box 48 78 22 Unit 3206, Floor 32, Jumeirah Business Center 5, Jumeirah Lakes Towers, Dubai United Arab Emirates Mail 11 Commerce Crescent West Eastgate, Sandton PO Box 786117 Sandton 2146 South Africa Phone
+971 4 390 09 80 Fax
+971 4 390 86 23 Phone
+ 27 11-719-6000 Fax
+ 27 11-444-5393 E-mail wisupport@commscope.com E-mail wisupport@commscope.com table 1-1 List of international contact addresses Page 14 Users Manual for ION-U 7/8/85/17/19 0 Introduction Introduction 1.4. Purpose Cellular telephone systems transmit signals in two directions between base transceiver station (BTS) and mobile stations (MS) within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system. Such a system contains an optical Master Unit and several Remote Units. The number of the Remote Units depends on the hardware and software configuration. The Remote Units are connected to the Master Unit with optical links. The Master Unit is the connection to the base transceiver stations. The configuration of a Master Unit depends on the number of the Remote Units and the frequency range. RF signals are transported to the remote units via optical fibers. 1.5. The ION-U L 7/8/85/17/19 Remote Unit The ION-U 7/8/85/17/19 is a low power remote unit for Cell700, LMR800, Cell850, AWS, and Extended PCS1900 Band Applications. The unit is compatible with analog, GSM, EDGE, IS-95, CDMA2000, EVDO, W-CDMA, HSDPA, and LTE modulation standards. It is used in conjunction with a Master Unit in the ION optical distribution system. This system transports multiple signals simultaneously, providing a cost-
effective solution for distributing capacity from one or more base stations. The ION-U 7/8/85/17/19 transports signals on the RF layer in a very inexpensive manner. This means that multiple operators and multiple technologies are moved simultaneously from a cluster of base stations to a remote location over the same fiber. The ION optical distribution system is a cost-effective coverage solution for dense urban areas, tunnels, subway, airports, convention centers, high-rise buildings, and other locations where physical structures increase path loss. It has been specifically designed to reduce zoning problems and to provide homogeneous coverage and capacity. MF0147A0A Page 15 0 Introduction The ION-U L 7/8/85/17/19 is capable of supporting both SISO and MIMO. RF signals are transported to the remote units via single mode fiber at 1310 nm. MIMO is achieved with the use of 4 fibers and the pairing of two interlinking RUs. The system includes an Automatic Gain Control (AGC) that avoids field adjustments and reduces design, installation, and optimization time. The ION is easily set-up and supervised via a graphical user interface (GUI). Remote Units can be commissioned using built-in is compensated through the AGC. Autolevelling allows the output power to be levelled as specified in the system configuration. The entire system may be monitored remotely via an Andrew OMC. This platform uses SNMP protocol and is compliant to X.733 standard. Should a sophisticated interface not be required, the Master Unit can be directly connected to the alarm interface of a base station via a LAN (local area network) or its contact relay. Features at a glance:
test equipment. Optical Loss Full band, fully transparent operations Compatible with Analog, GSM, EDGE, IS-95, CDMA2000, EVDO, W-CDMA, HSDPA, and LTE modulation standards 5 dB optical budget compensated through AGC Enhanced communication channel for remote control/setting and SW download Independent uplink automatic level control (ALC) on each band 1 antenna port External alarm inputs Wideband auxiliary channel Internal swappable power supply adapter Centralized power supply optionally available Page 16 Users Manual for ION-U 7/8/85/17/19 2 Functional Description 2. Functional Description In the Downlink (DL) path, the remote unit provides:
Optical to RF conversion of the input optical signal Automatic Gain Control (AGC) of each converted signal to compensate for optical losses RF amplification of the converted RF signal for transmission while maintaining a good signal-to-noise ratio RF filtering to reject spurious emissions In the Uplink (UL) path, the remote unit provides:
RF amplification to boost the signals received by the antennas to maintain a good signal-to-noise ratio RF filtering to reject spurious emissions Automatic Level Control (ALC) to adjust the RF signal level to meet blocking requirements RF-to-optical conversion of the signal, which is convey to the output optical port 2.1. SISO and MIMO Operation The modular architecture of the ION-U 7/8/85/17/19 supports both SISO and MIMO operation. MIMO operation is achieved by pairing two RUs. The following figures show views of a single ION-U 7/8/85/17/19 remote unit for SISO applications and two ION-U 7/8/85/17/19 remote units paired for MIMO applications. figure 2-1 Remote unit, SISO figure 2-2 Remote unit, MIMO Two units paired MF0147A0A Page 17 2.2. ION-U 7/8/85/17/19 Ports 2 Functional Description The RF, optical, mains power, alarm, power control, and expansion ports are located on the bottom of the RU as shown in figure 2-3. C D B E A F G H I J K G DL optical port H UL optical port I Mains power connector J RF antenna port K Grounding (earthing) bolt A Local Port RS-232 B Status LED C Pwr/Ctrl connector D Alarm connector E Expansion UL port F Expansion DL port figure 2-3 RU Connectors and Status LED Antenna Port The RU has one duplex N-female antenna port for transmitting and receiving signals to and from distributed antennas. This RF port can be connected directly to an antenna (i.e. using RF jumper cables) or through splitters, allowing additional antennas to be fed by the RU. J Status LED The status LED provides a visual warning of an alarm condition. The color of the LED indicates the severity of the alarm. Expansion Ports The Expansion UL and Expansion DL ports are used to connect to a CommScope expansion unit to provide additional bands. are QMA female connectors that E F Page 18 Users Manual for ION-U 7/8/85/17/19 2 Functional Description Optical Ports The LC-APC optical connectors are used to send and receive the signals between the RU and the Master Units OTRx modules. The DL optical port The UL optical port G H receives downlink signals from the MU OTRx. transmits uplink signals to the MU OTRx. Mains Connector The RU receives its power through the Mains connector
. The type of connector is dependent on the RU model. A 4-pin Amphenol connector is used for AC models and standard DC models. A 7-pin Amphenol connector is used for DC models powered by a duel cable supply. I Pwr/Ctrl Connector The Pwr/Ctrl connector supports an optional fan unit. The RU provides power and fan speed control to the fan unit and receives alarms from it through this 7-pin Binder connector. C Alarm connector The RU has two alarm relay inputs that can be used to monitor and report alarms from external devices. The Alarm connector is a 5-pin Binder connector. D Local Port RS-232 is standard DB-9 female connector used for external modem The RS-232 port communication with an optional extension unit and for local connection to a laptop PC. A MF0147A0A Page 19 3. Commissioning 3.1. Mechanical Installation 3 Commissioning 3.1.1. General Read the health and safety warnings in chapter 1.2. 1. Warning: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. Warning: It is recommended to use the mounting hardware delivered by the the manufacturer only. specifications for stationary use of the Remote Unit must not be exceeded. Note: Exceeding the specified load limits may cause the loss of warranty!
If different mounting hardware is used, 3. Warning: The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 4. Caution: Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 5. Note: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables. 6. Note: Observe all additional rules or restrictions regarding mounting that apply to specific Remote Unit types. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Remote Unit. Specified torques must be observed for certain mounting procedures according to the following table:
Type Tallow-drop screws Thread Specified torques M 4 3.3 Nm Spacing Hex
(plastic) nuts M 8 M 4 PG 13.5 PG 29 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm bolts M 8 PG PG
(aluminium) table 3-1 Specified torques Users Manual for ION-U 7/8/85/17/19 Page 20 3 Commissioning 3.1.2. Wall-Mounting Procedure 1. Check the suitability of the wall-mounting kit and the wall. 2. Install the
(not wall-mounting bracket using 4 M6 screw anchors included*) according to the drilling layout. Confirm that the bracket is securely fastened to the wall.
* The M6 screw anchors are not included as part of the RU delivery because the suitable type depends on the on-site conditions (wall structure and materials). Therefore, use screw are appropriate for the mounting surface. anchors that figure 3-1 Wall-mounting bracket 3. Attach the M6 threaded pins to the Remote Unit (on the both sides). figure 3-2 RU threaded pins MF0147A0A Page 21 3 Commissioning bracket 4. Install the Remote Unit on the wall-mounting by lifting the RU into place and lowering the bracket. The M6 pins must align with the slots in the bracket to support the RU. it down onto figure 3-3 RU placed on wall mounting bracket 5. Fasten the lower section of the Remote Unit to the bracket using a washer and a M6x12 screw (on both sides). Slide a washer over each screw and then the screw and tighten it securely. insert figure 3-4 Install M6x12 screws and washers Page 22 Users Manual for ION-U 7/8/85/17/19 B0303A8AM6x12 screwWasherB0303A9A figure 3-5 Attach M6 nut to threaded pins 3 Commissioning 6. Fasten the Remote Unit to the bracket using a washer and M6 nut. Slide the washer over the threaded pins that were installed in step 3 and then screw the nut onto the pins
(on both sides) and tighten securely. 7. Confirm that all screws and nuts have been fastened and the unit is securely mounted to the wall. MIMO mounting instructions figure 3-6 Completed SISO RU Mount MF0147A0A Page 23 M6 nutWasherB0303AAA 3 Commissioning 3.2. Electrical Installation 3.2.1. General Read the health and safety warnings in chapter 1.2. 1. Warning: This unit contains dangerous voltages. Loss of life, severe personal injury, or property damage can be the result if the instructions contained in this manual are not followed. 2. Caution: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Caution: Although the remote unit is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the remote unit for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 4. Caution: If the mains connector of the remote unit is not easily accessible, a disconnect device in the mains power circuit must be provided within easy reach. 5. Caution: Before connecting or disconnecting the mains connector at the remote unit, ensure that mains power supply is disconnected. 6. Caution: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by IEC/EN60950-1) and an overcurrent limiting device are connected between mains power and the Remote Unit. 7. Caution: A connection of the mains supply to a power socket requires the power socket to be nearby the remote unit. 8. Caution: Incorrectly wired connections can destroy electrical and electronic components. 9. Caution: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. Note: Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the CommScope e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. Page 24 Users Manual for ION-U 7/8/85/17/19 3 Commissioning 11. Caution: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised. 12. Caution: The unit complies with the surge requirement according to EN 61000-4-
5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection (external surge protection) is recommended depending on the individual application in order to avoid damage caused by overcurrent. 13. Caution: Observe the labels on the front panels before connecting or disconnecting any cables. MF0147A0A Page 25 3 Commissioning 3.2.2. Connections The ION-U RU ports and connectors shown below are located at the base of the RU. figure 3-7 ION-U L 7/8/85/17/19 Connectors ION-U L 7/8/85/17/19 Connectors/Indicators Purpose This connector is used for external modem communication with an optional extension unit and for local connection to a laptop PC. This LED provides a visual warning of an alarm condition. The color of the LED indicates the severity of the alarm. This connector supports an optional fan unit. The RU provides power and fan speed control to the fan unit and receives alarms from it. This connector provides alarm contacts that are used to monitor and report alarms generated by other equipment. This connector is used to connect to the UL port of an expansion unit to provide additional bands of coverage Type DB-9 Female LED Binder 712 series 7-pin Binder 712 series 5-pin QMA Female Users Manual for ION-U 7/8/85/17/19 Port/Conn LOCAL RS-232 STATUS PWR/CTRL ALARM EXPANSION UL Page 26 3 Commissioning Port/Conn EXPANSION DL ION-U L 7/8/85/17/19 Connectors/Indicators Purpose This connector is used to connect to the DL port of an expansion unit to provide additional bands of coverage Type QMA Female OPTICS UL This connector is used to connect an optical fiber LC-APC OPTICS DL MAINS
(Vac/Vdc) MAINS
(Vdc/100) cable to send uplink signal back to the OTRx module of the ION-U master unit This connector is used to connect an optical fiber cable to receive downlink signal from the OTRx module of the ION-U master unit This connector provides the power to RU models that use standard AC (85 to 265 Vac) or RU models that use standard DC (-60 to -38 Vdc) power. This connector provides the power to RU models used in locations where the power drawn on each cable must be limited to a maximum of 100 VA. LC-APC Amphenol C016 Series, 4-Pin Amphenol C016 Series, 7-Pin Grounding Bolt Ground (earth) bolt for connecting the mandatory M8 bolt, hex ANT RF ground cable to the RU This connector is used for transmitting and receiving signals to and from an antenna or antenna splitter. nut, & washers N-type female table 3-2: ION-U L 7/8/85/17/19 Connectors MF0147A0A Page 27 3 Commissioning 3.2.3. Grounding (Earthing) The RU must be grounded (earthed). 1. Connect an earth-bonding cable to the grounding bolt connection provided on the outside of the remote unit (near the Mains connector) as shown in figure 3-8. Do not use the grounding connection to connect external devices. figure 3-8 Grounding bolt figure 3-9 Grounding bolt, schematic view 2. After loosening the hex nut, connect the earth-bonding cable between the two washers as illustrated in the figures above. 3. Then, fasten all parts again by tightening the the hex nut. 4. Connect the other end of the ground wire to a suitable permanent ground following local electrical code practices. Page 28 Users Manual for ION-U 7/8/85/17/19 3 Commissioning 3.2.4. Mains Power Connection Before connecting electrical power to the units, the system must be grounded
(earthed) as described in the previous chapter. The Mains power must be connected to the Mains connector of the unit for operation of the RU. A power cable is delivered with each RU. The type of power cable delivered is dependent on the type of power supply in the RU. The AC power cable is a 3.2 m (10.5 ft) 16 AWG cable with a 4-pin Amphenol C016 series plug on one end to connect to the RU Mains connector. The other end of the cable is un-terminated with 3 end splices to connect to the AC power source. A 10 m
(33.7 ft) AC power cable (part no. 7573605-00) is also available as an option. The AC power cable is shown in figure 3-10. 4-Pin Amphenol C016 Series figure 3-10 AC power cable Color Brown Blue n.c Pin Name 1 Phase 2 Neutral 3 4 Ground Yellow /
Green n.c. table 3-3 AC power cable The standard DC power cable is a 3.2 m (10.5 ft) 13 AWG cable with a 4-pin Amphenol C016 series plug on one end to connect to the RU Mains connector. The other end of the cable is un-terminated with 2 end splices to connect to the -48 Vdc power source. The standard DC power cable is shown in figure 3-11. 4-Pin Amphenol C016 Series Pin Name Color 1 2 3 4 n.c 48V 0V n.c. n.c Black Red n.c figure 3-11 DC power cable table 3-4 DC power cable MF0147A0A Page 29 blueAmphenol 4-Pinfemale connectorProtective Cap3x end splicebrownyellow / greenB0302ASARU MainsConnector4321blackAmphenol 4-Pinfemale connectorProtective Cap2x end spliceredB0302ATARU MainsConnector4321 3 Commissioning The Vdc/100 power cable is available for locations where the power drawn on each cable must be limited to a maximum of 100 VA. This cable is a 3.2 m (10.5 ft) 16 AWG cable with a 7-pin Amphenol C016 series plug on one end to connect to the RU Mains connector. The other end of the cable is un-terminated with 4 end splices to connect to the -48 vdc power source. 7-Pin Amphenol C016 Series Pin Name Color 0V 48V n.c. 0V 1 2 3 4 5 6 7 Ground 48V n.c figure 3-12 Vdc/100 power cable table 3-5 Vdc/100 power cable For the AC power supply connection, a minimum cross section of 1.5 mm2 is required and for the DC power supply connection, a minimum cross section of 2.5 mm2 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. Note: Do not connect or disconnect the power cable at the mains connector while power is on. Turn off mains* power before connecting the power cable at the remote unit, then, engage mains power again.
* Mains power must be interruptible with an external mains breaker. For the mains breaker, observe the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240-Volt service. For the DC power supply, observe the local regulations of the DC service provider. Use the following method to install and connect the Mains power to the RU:
1. Locate the Mains power cable that was delivered with the RU. 2. Locate or install a suitable power junction box or receptacle near the RU and route the power cable from the power source to the RU. Do not connect the cable to the RUs Mains connector at this time. The power source must be interruptible. Page 30 Users Manual for ION-U 7/8/85/17/19 12457Amphenol 7-Pinfemale connectorProtective Cap4x end spliceB0302AUARU MainsConnector 3 Commissioning 3. The Mains cable must be properly secured observing local regulations and electrical codes. Be sure to allow enough slack in the cable at the RU to plug or unplug the cable into the Mains connector of the RU. 4. Wire the power cable to the junction box or receptacle. Refer to the color code and pin numbers shown in figure 3-10 (AC cable), figure 3-11 (DC cable), or figure 3-12 (Vdc/100 cable) depending on the type of power supply used by the RU. 5. With the cables Mains plug disconnected from the RU, turn the circuit breaker on, unscrew the plugs protective cover, and carefully test the plug with a voltmeter to ensure that the voltage and polarity are correct. 6. Once the testing has been completed, turn off the circuit breaker. 7. Unscrew the protective cover from the Mains connector of the RU. 8. Insert the plug into the Mains connector (figure 3-13) and tighten the clamping ring until it is hand tight. Do not over-tighten the clamping ring. Clamping ring Mains plug Mains connector figure 3-13 Connect Mains plug 3.2.5. Antenna Connection The Remote Unit has one N-type antenna connector (figure 3-14). For mounting the cable connector, it is recommended to refer to the corresponding documentation of the connector manufacturer. The bending radius of the antenna cables must remain within the given specifications. MF0147A0A Page 31 3 Commissioning The selection of cable and antenna is an important consideration. On the one hand, a cable with higher loss is less expensive but, on the other hand, it impairs performance. Use an appropriate torque wrench for the coupling torque of N-type connectors (2 N-m / 20 in lb), with 13/16 in opening to tighten the N-type antenna connectors. For example, use torque wrench of item no. 244379 available from the CommScope e-catalog. Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the Remote Unit. To minimize passive inter-modulation (PIM) distortion, attention must be paid to the physical condition of the connector junctions. Do not use connectors that show signs of corrosion on the metal surface. Prevent the ingress of water into the connector. Attach and torque the connectors properly. 1. Route the antenna cable from the antenna or splitter to the base of the RU. 2. Cut the cable to length and terminate the cable with an N-type male connector. 3. Remove the red plastic protective cover from the N-type female connector. 4. Using an appropriate torque wrench, connect the cable to the antenna port of the RU. N-type antenna connector Antenna cable figure 3-14 N-type antenna connection 3.2.6. Expansion Ports Connections The Expansion ports are QMA-F connectors that are used to connect to an expansion unit to provide additional bands of coverage. Page 32 Users Manual for ION-U 7/8/85/17/19 3 Commissioning 1. Connect an RF cable with QMA male connectors between the UL Expansion port connector of the RU to the UL port of the expansion unit. Press the QMA connector of the cable onto the UL port of the RU until it clicks into place to connect the cable. 2. Connect an RF cable with QMA male connectors between the DL Expansion port connector of the RU to the DL port of the expansion unit. Press the QMA connector of the cable onto the DL port of the RU until it clicks into place to connect the cable. UL To Expansion unit DL figure 3-15 Expansion ports 3.2.7. Alarm Port The Alarm port provides alarm contacts that are used to monitor and report alarms generated by other equipment. The connector is a 5-pin Binder 712 series connector. 5-Pin Binder 712 Pin 1 2 3 4 5 Series Assignment EXT1_Alarm EXT1_GND n.c. EXT2_Alarm EXT_GND table 3-6 Alarm Connector figure 3-16 Alarm Connector 3.2.8. Pwr/Ctrl Port The Pwr/Ctrl port is used to handle an optional fan unit. The connector will provide power to the fan unit and will allow the RU to control the fan speed. The connector is a 7-pin Binder 712 series connector. MF0147A0A Page 33 51B303ALA figure 3-17 Pwr/Ctrl Connector 3 Commissioning 7-Pin Binder 712 Series Assignment
+V_FAN Fan1 Alarm In Fan1 (PWM) Out GND_FAN Fan2 Alarm In Fan2 (PWM) Out n.c Pin 1 2 3 4 5 6 7 table 3-7 Pwr/Ctrl Connector 3.2.9. Control Connector RS-232 - Local Interface This DB-9 female connector is used for external modem communication with a possible extension unit and for local connection with a laptop. DB-9 Female PIN Assignment 1 2 3 4 5 6 7 8 Not connected (n.c.) RS232 Rx RS232 Tx n.c. GND (RS232) n.c. n.c. n.c. figure 3-18 RS-232 connector table 3-8 RS-232 connector, pin assignment Page 34 Users Manual for ION-U 7/8/85/17/19 71B303AMA1659B303APA 3 Commissioning 3.3. Optical-Fiber-Cable Connection - Rules Main optical system parameters:
Fiber:
Single mode fiber, type is 9.5/125 m Fiber-cable connectors LC/APC ION-U system:
The pigtails for the connection between Master Unit and Remote Unit must have a sufficient length. Protection for the optical fibers must be provided where the fibers feed into the units. The system attenuation of the optical fibers, including the connectors, must not exceed 5 dB. System attenuation and attenuation of optical components must be determined. This can be achieved by measuring attenuation and reflection with an appropriate measuring instrument. For pigtails, a total value of < 0.4 dB (measured to a reference plug) can be assumed due to the dead zone of the reflectometer. These measurements must be made with a sufficient length of optical fiber, at the input and output of the device which has to be measured. Fiber-System Installation:
Fiber-cable connectors have to be of the same type (LC/APC) as the connectors used for the unit. The fiber-optic cables are connected to the optical transceiver. Angled connectors are not compatible with straight optical connectors;
non-compatibility of connectors will result in permanent damage to both connectors. Before connecting the fiber cables, follow the procedure below to ensure optimized performance. It is important for these procedures to be carried out with care:
Remove fiber-optic protective caps just before making the fiber connections. Do not leave any LC/APC connectors open as they may attract dirt. Unused optical connectors must always be covered by their caps. Do not bend the fiber-optic cable in a tight radius (< 5 cm) as this may cause damage to the cable and interrupt transmission. Using high-grade alcohol and lint-free cotton cleaning swabs, clean the end of the fiber-optic cable that will be inserted in the optical connectors on the donor interface box. Use a fiber end-face inspection tool to scan both, the class fiber and its surrounding area. Check for dirt on the cladding, chips/pits, dirt on the ferrule, and scratches. MF0147A0A Page 35 3 Commissioning Connect the fiber-optic cables by inserting the cable end into the laser receptacle. Do not use any index-matching gels or fluids of any kind in these connectors. Gels are intended for laboratory use and attract dirt in the field. Note:
Care should be taken when connecting and disconnecting fiber-
optic cables - use the connector housing to plug or unplug a fiber. Scratches and dust significantly affect system performance and may permanently damage the connector. Always use protective caps on fiber-optic connectors not in use. Cleaning Procedure for Fiber-Optical Components:
Any contamination in the fiber connection results in additional optical transmission loss which could cause whole system failure. It is thus recommended that every fiber connector be inspected and cleaned prior to mating. The goal is to eliminate any dust or contamination and to provide a clean environment for the fiber-optic connection. When you clean fiber components, always complete the following steps carefully:
1. Turn off the ION-U system (laser sources) before you inspect fiber connectors. Never look into a fiber while the system lasers are on!
2. Check the connectors or adapters with a fiberscope before cleaning. 3. If the connector is dirty, clean it with a lint-free wipe (dry cleaning). 4. Inspect the connector. 5. If the connector is still dirty, repeat the dry cleaning technique. 6. Inspect the connector. 7. If the connector is still dirty, clean it with 99% isopropyl alcohol (wet cleaning) followed immediately with a dry clean in order to ensure no residue is left on the endface. 8. Repeat steps 5 through 7 until endface is clean. Note: For a more detailed description, please refer to:
http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186 a0080254eba.shtml Page 36 Users Manual for ION-U 7/8/85/17/19 3 Commissioning 3.3.1. Optical cable installation 1. Locate the Optics connector cover on the lower right side of the RU. Loosen the four cover screws, remove the cover, and set it aside. Removing this cover allows access to the UP and DL optical connectors. Cover Screws Optical Connectors figure 3-19 Remove optics cover 2. Remove the sealing nut from the optical cable gland at the bottom of the RU. Sealing nut figure 3-20 Remove sealing nut 3. Remove the split-seal by pulling it downward and out of the clamp ring. Cable gland clamp ring Split-seal Cable gland clamp ring with split seal removed figure 3-21 Remove split-seal 4. Insert the UL and DL optical cables through the sealing nut as shown in figure 3-22. MF0147A0A Page 37 3 Commissioning Sealing nut figure 3-22 Insert fiber optic cables through sealing nut 5. Then insert the optical cables through the opening in the cable gland clamp ring 6. Connect the optical cables to the proper UL and DL LC/APC connectors. Connect LC/APC Optical Cables Clamp ring figure 3-23 Insert cables through clamp ring 7. Separate the two halves of the split-seal. Place each cable into one of the grooves in the lower half of the split-seal. Place the other half of the split-seal over the fiber optic cables. Split-seal figure 3-24 Place cables into split-seal Split-seal Split-seal grooves Page 38 Users Manual for ION-U 7/8/85/17/19 3 Commissioning 8. Press the split-seal up into the clamp ring opening. Split-seal figure 3-25 Press split-seal into opening Sealing nut 9. Tighten the sealing nut securely. Sealing nut figure 3-26 Tighten sealing nut 10. Replace the optics metal cover and tighten the four screws that were loosened in step 1. 3.3.2. Commissioning Read the health and safety warnings in chapter 3.3.2 Commissioning as well as the description carefully to avoid mistakes and proceed step-by-step as described!
Do not operate the remote unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load. Only qualified personnel should carry out the electrical, mechanical, commissioning, and maintenance activities that require the unit to be powered on when open. When opening the remote unit do not damage the warranty labels on the internal devices. The warranty is void if the seals are broken. Ensure that all connections have been performed according to chapter 3.2.2 Connections. MF0147A0A Page 39 4. Alarms 4.1. Bite and Alarms 4 Alarms The Built-In Test concept comprises the monitoring of the power supplies, the power amplifiers, and the optical interface. All alarms that occur can be checked via software at the master unit. 4.2. Handling of Alarms As soon as the software acknowledges a valid alarm, a message is transmitted to the master unit. If the reason for the alarm has been cleared or if the alarm should continue, a new alarm message will not be repeated. If there is an interruption of at least five seconds after acknowledgement, a new alarm message will be generated. figure 4-1 Alarm triggering Page 40 Users Manual for ION-U 7/8/85/17/19 V1651A2clearAlarm LEDAlarm transmitAlarm causeraise> 5 s< 5 sraise> 5 sclear 4 Alarms 4.3. Status LED Alarms For local supervision, a status LED on the connector panel of the remote unit adjacent to the Expansion ports provides a visual warning of an alarm condition. The color of the LED indicates the severity of the alarm. Detailed alarm information is available through the ION-U software interface. This table lists the alarm conditions and possible on-site measures that could be performed to resolve the issues responsible for triggering the alarms. Alarm Name Description Remedy Fan Failure DL optical power fail Temperature Alarm VSWR Alarm RF Low Output CELL700 RF Low Output CELL 850 RF Low Output LMR 800 RF Low Output PCS 1900E Received optical power below minimum threshold temperature too high bad RF cabling /
mismatched antenna RF signal too low RF signal too low RF signal too low RF signal too low RF Low Output AWS RF signal too low check ventilation and environment check fiber connections and transmitted optical power check ventilation and environment Default Severity critical major LED Red Red warning Green check cable / antenna critical Yellow check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling minor Green minor Green minor Green minor Green minor Green DL CELL 700 band alarm DL LMR800+CELL850 alarm DL PCS 1900E band alarm hw failure in RF section change unit critical Red hw failure in RF section change unit critical Red hw failure in RF section change unit critical Red DL AWS band alarm hw failure in RF section change unit critical Red UL CELL 700 band alarm UL LMR800+CELL850 band alarm UL PCS 1900E band alarm UL AWS band alarm UL Overdrive/ALC Limiting CELL 700 UL Overdrive/ALC Limiting LMR800+CELL850 UL Overdrive/ALC Limiting PCS 1900E UL Overdrive/ALC Limiting AWS Internal bus alarm UL Laser Alarm hw failure in RF section change unit critical Red hw failure in RF section change unit critical Red hw failure in RF section change unit change unit critical critical Red Red hw failure on RF section too high RF signal feeding device too high RF signal feeding device RF signal feeding device too high RF signal feeding device too high internal I2CBUS communication malfunction Uplink laser fail (cooling or current failure) check unit/attenuator configuration minor Green check unit/attenuator configuration minor Green check unit/attenuator configuration minor Green check unit/attenuator configuration minor Green change unit change unit critical Red major Red External 1 Alarm external input alarm check external device/ check alarm connection major Yellow MF0147A0A Page 41 Alarm Name Description Remedy External 2 Alarm external input alarm RF High Output CELL700 RF High Output CELL 850 RF High Output LMR 800 RF High Output PCS 1900E RF signal too high RF signal too high RF signal too high RF signal too high RF High Output AWS RF signal too high Power Supply 1 Alarm Power Supply 2 Alarm internal power supply alarm internal power supply alarm 4 Alarms Default Severity LED major Yellow major Green major Green major Green major Green major Green check external device/ check alarm connection check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling check BTS output level/attenuator configuration/RF cabling change/verify unit major Red change/verify unit major Red Power Supply 1 exceeded load threshold Power Supply 2 exceeded load threshold power supply load too high change/verify unit minor Green power supply load too high change/verify unit minor Green Power Supply 1 partial availability Power Supply 2 partial availability internal power supply alarm / partial power available internal power supply alarm / partial power available change/verify unit major Green change/verify unit major Green High Power Consumption Low Power Consumption power supply load too high change/verify unit minor Green power supply load too low change/verify unit minor Green table 4-1 Status LED alarms 4.4. External Alarm Inputs With the external alarm inputs, it is possible to monitor the status of connected devices, e.g. a UPS, via software. All alarm inputs are normally high (5 V) without connection. The polarity (high/ low) can be set via the software at the Master Unit (for details please see the appropriate ION-U software manual). The device to be monitored must be connected so that the alarm contacts will be closed in case of an alarm (I max = 8 mA). The alarm inputs are potential-free with common ground (earth). Subminiature circular connectors series 712 with five contacts, which are contained in the alarm kit, can be ordered directly from the Binder Connector Group, the manufacturer, or indirectly from CommScope. For the designation of the alarm kit see chapter 6.5 Spare Parts. Page 42 Users Manual for ION-U 7/8/85/17/19 4 Alarms 4.5. Troubleshooting The status of the remote unit can be checked via the master unit (for details please refer to the ION-U software manual). Locally, the status can be checked at the LED, see chapter 4.3 Status LED Alarms. MF0147A0A Page 43 5. Maintenance 5.1. General 5 Maintenance Read the health and safety warnings in chapter 1.2. Note:
The remote unit does not require preventative maintenance measures. Maintenance of the ION-U L 7/8/85/17/19 should be performed by replacing only components that are described in this chapter. In order to maintain the warranty, avoid unintentional damage to the seals on the modules. The spare parts list, includes only units that can be replaced in the field without tuning or soldering work. Note: When sending back the unit, use appropriate packaging. Use of is strongly for shipping the unit the original packaging recommended!
Note:
Note:
Note:
Defective parts should only be replaced by original parts from the supplier. All service work performed inside the housing is performed at the users own risk. Ensure the Remote Unit has been disconnected from mains power during maintenance. Label any unlabelled cables before disconnecting them to ensure correct reconnection. For most maintenance procedures, appropriate tools are required to ensure correct handling. All of these tools can be ordered from the supplier. Note: All Remote Unit screws have a right-hand thread, and are tightened by turning the screws clockwise and loosened by turning them counter-clockwise with an appropriate tool. Due to the design of the remote unit, the power supply is the only component that should be replaced in the field. Please contact the supplier for replacement of any other components. Page 44 Users Manual for ION-U 7/8/85/17/19 5 Maintenance 5.2. RU Power Supply Replacement The power supply for the RU is a field replaceable module. The type of power supply used by the RU (AC, DC, or Vdc/100) is dependent on the model number of the RU. Before starting any maintenance on the RU, read the health and safety warnings in chapter 1.2 and the electrical installation general information in chapter 4.2.1. 1. Switch off the circuit breaker supplying power to the RU. 2. Once you have confirmed that the power has been shutdown, remove power connector from the RU. Mains 3. Locate the power supply on the right side of the Remote Unit. Mains plug figure 5-1 Disconnect Mains power Power supply MF0147A0A figure 5-2 RU power supply location Page 45 4. Use a #2 Phillips head or slotted screwdriver to loosen the 8 universal slot/Phillips captive power supply screws the and carefully remove supply. The weight of the power supply must be supported as you loosen the screws to prevent damage to the supply. 5. Carefully remove the power supply from the unit. Do not attempt to support the weight of the supply with the attached input and output cables. 6. Locate the input cable connector the power supply on the right side of the supply. for 7. Loosen the 3 Phillips head terminal screws and remove the connector. 5 Maintenance Loosen 8 universal slot/Phillips screws Mains connector figure 5-3 8 RU power supply screws figure 5-4 RU power supply with cables figure 5-5 RU power supply input cable Page 46 Users Manual for ION-U 7/8/85/17/19 5 Maintenance 8. Locate the output connector for the power supply on the left side of the supply. 9. Loosen the 2 Phillips head screws and remove the output connector. figure 5-6 RU power supply output cable 10. Remove the defective supply. 11. Replace the defective power supply with the new power supply. It is very important to confirm that the replacement supply is the same type as the original supply. The AC, DC, and Vdc/100 supplies are not interchangeable. 12. Reconnect the input and output connectors, and tighten the terminal screws. associated figure 5-7 Ru with power supply removed figure 5-8 Ru with replacement power supply MF0147A0A Page 47 5 Maintenance 13. Insert the power supply into the RU carefully to avoid damaging any cables. The supply must be supported until the 8 universal slot/Phillips captive power supply screws have been tightened. 14. Tighten the slot/Phillips supply screws. 8 universal captive power figure 5-9 Ru insert power supply 15. Reconnect the Mains power plug. 16. Switch on the breaker and for proper the RU check operation. Page 48 figure 5-10 Reconnect Mains power Users Manual for ION-U 7/8/85/17/19 6 Appendix 6. Appendix 6.1. Illustrations Need drawings with dimensions here figure 6-1 Installation drawing MF0147A0A Page 49 6.2. Electrical Specifications 6 Appendix Please refer to the ION-U_LP_RU_US_PA-106156-EN.GB.pdf data sheet for the Remote Units electrical specifications. 6.3. Environmental and Safety Specifications Please refer to the ION-U_LP_RU_US_PA-106156-EN.GB.pdf data sheet for the Remote Units environmental and safety specifications. 6.4. Mechanical Specifications Please refer to the ION-U_LP_RU_US_PA-106156-EN.GB.pdf data sheet for the Remote Units mechanical specifications. Page 50 Users Manual for ION-U 7/8/85/17/19 7 Index 6.5. Spare Parts The following table lists the spare parts available for the Remote Unit. The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of the delivery. Maintenance of the ION-U L 7/8/85/17/19 should be performed on an FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty. If a FRU which is not included in the following list needs to be replaced, please contact customer service for additional instructions. ION-U L 7/8/85/17/19 Spare Parts List Designation:
Need Spare Parts Need Accessories and part numbers Accessories ID No:
Need ID Numbers The manufacturer reserves the right to replace the spare parts listed above by equivalent substitutes!
Note: Only the spare parts listed above are FRUs (= Field Replaceable Units) and can be replaced by the user. For replacement of any other parts, please send the entire Remote Unit back to the manufacturer. MF0147A0A Page 51 7. Index A Abbreviations .......................................................... 7 ALARM ................................................................. 27 Alarm connector ................................................... 20 Alarm port ....................................................... 27, 34 Alarms Bite and Alarms ............................................... 41 External Inputs ................................................. 43 Handling of Alarms .......................................... 41 Status LED ....................................................... 42 Amphenol C016 series plug.................................. 30 ANT RF ................................................................ 28 Antenna Port ....................................................... 19 B Block Diagram ION-U L 7/8/85/9/17/19 RU.............................. 17 C CE Declaration of Conformity (DoC) ..................... 11 Commissioning General ............................................................ 40 CommScope ......................................................... 11 Connection Rules Optical-Fiber Cables ........................................ 36 Connections Antenna ..................................................... 32, 33 Connector Panel .............................................. 27 Power .............................................................. 30 Contact Addresses Customer Support ................................ 12, 13, 14 Customer Support Addresses................... 12, 13, 14 D Declaration of Conformity (DoC) ........................... 11 E EXPANSION DL ................................................... 28 Expansion ports .................................................... 33 Expansion Ports ................................................. 19 EXPANSION UL ................................................... 27 F Fiber-Optical Components Cleaning Procedure ......................................... 37 System Installation ........................................... 36 7 Index H Health and Safety Warnings ................................... 8 I Illustrations ........................................................... 50 Installation Electrical .......................................................... 25 Mechanical ...................................................... 21 ION-U 7/8/85/9/17/19 ........................................... 15 ION-U 7/8/85/9/17/19 RU Ports ............................ 19 M MAINS (Vac/Vdc) ................................................. 28 MAINS (Vdc/100) ................................................. 28 Mains connector ............................................. 20, 30 Maintenance ......................................................... 45 MIMO applications ................................................ 18 Mounting Wall .................................................................. 22 O Optical cable installation ....................................... 38 Optical Ports ....................................................... 20 OPTICS UL .......................................................... 28 P PWR/CTRL ........................................................... 27 Pwr/Ctrl connector .......................................... 20, 27 R RS-232 ................................................................. 27 RS-232 port .......................................................... 20 RU AC power cable .............................................. 30 RU DC power cable .............................................. 30 RU Power Supply Replacement ........................... 46 RU Vdc/100 power cable ...................................... 31 S SISO applications ................................................. 18 Spare Parts .......................................................... 52 Specifications Electrical .......................................................... 51 Environmental and Safety ................................ 51 Mechanical ...................................................... 51 Status ................................................................... 27 G T Grounding (Earthing) ............................................ 29 Grounding Bolt ...................................................... 28 Page 52 Troubleshooting .................................................... 44 Users Manual for ION-U 7/8/85/17/19