all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 |
|
Installation Instruction | Users Manual | 249.45 KiB | April 28 2021 | |||
1 2 3 |
|
Users Manual | Users Manual | 3.04 MiB | April 28 2021 | |||
1 2 3 |
|
Internal Photos | Internal Photos | 2.88 MiB | April 28 2021 | |||
1 2 3 |
|
External Photos | External Photos | 1.32 MiB | April 28 2021 | |||
1 2 3 |
|
Label Information | ID Label/Location Info | 912.56 KiB | April 28 2021 | |||
1 2 3 | Block Diagram | Block Diagram | April 28 2021 | confidential | ||||
1 2 3 |
|
LTC Request | Cover Letter(s) | 325.19 KiB | April 28 2021 | |||
1 2 3 | Operational Description | Operational Description | April 28 2021 | confidential | ||||
1 2 3 |
|
Power of Attorney Letter | Cover Letter(s) | 167.70 KiB | April 28 2021 | |||
1 2 3 | Parts List Part 1 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 10 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 2 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 3 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 4 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 5 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 6 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 7 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 8 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Part 9 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 |
|
RF Exposure | RF Exposure Info | 232.70 KiB | April 28 2021 | |||
1 2 3 | Schematics | Schematics | April 28 2021 | confidential | ||||
1 2 3 |
|
Test Report Part 1 | Test Report | 4.76 MiB | April 28 2021 | |||
1 2 3 |
|
Test Report Part 2 | Test Report | 5.31 MiB | April 28 2021 | |||
1 2 3 |
|
Test Report Part 3 | Test Report | 4.75 MiB | April 28 2021 | |||
1 2 3 |
|
Test Report Part 4 | Test Report | 4.94 MiB | April 28 2021 | |||
1 2 3 |
|
Test Report Part 5 | Test Report | 4.26 MiB | April 28 2021 | |||
1 2 3 | Tune Up Information | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Waiver | Operational Description | April 28 2021 | confidential | ||||
1 2 3 |
|
Label Attestation | Attestation Statements | 2.33 MiB | April 28 2021 | |||
1 2 3 | Opertional Description | Operational Description | April 28 2021 | confidential | ||||
1 2 3 | Parts List Class A | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List Control Board | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List DL700 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List DL800 | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List DSP | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List LED | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List MUX | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List PLL-SUb | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List RF Class A | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 | Parts List UL | Parts List/Tune Up Info | April 28 2021 | confidential | ||||
1 2 3 |
|
Test Repot | Test Report | 4.07 MiB | April 28 2021 | |||
1 2 3 | Attestation Statements | |||||||
1 2 3 | ID Label/Location Info | |||||||
1 2 3 | ID Label/Location Info | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Report | |||||||
1 2 3 | Test Setup Photos |
1 2 3 | Installation Instruction | Users Manual | 249.45 KiB | April 28 2021 |
Installation Instruction The Remote Unit, Extension Unit or Master Unit must be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. Health and Safety for Mechanical Installation 1. Caution: Risk of injury by the considerable weight of the unit falling. Ensure there is adequate manpower to handle the weight of the system. 2. Caution: Risk of serious personal injury by equipment falling due to improper installation. The installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components. The screws and dowels (wall anchors) used should also be appropriate for the structure of the supporting wall. 3. Caution: Explosive atmospheres. To avoid explosion or fire, do not operate this equipment in the presence of flammable gases or fumes. 4. Caution: Lightning danger. Do not install or make adjustments to this equipment during an electrical storm. 1.1.2. Property Damage Warnings for Mechanical Installation 1. Attention: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. Otherwise, the lifespan and performance of the repeater may be reduced. 2. Attention: Due to power dissipation, the unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 3. Attention: The repeater must be installed in a vertical position. 4. Notice: Exceeding the specified load limits may cause the loss of warranty. 5. Notice: Do not place cables or tools that may damage the repeater in close proximity to it. 6. Notice: Do not wear jewelry or metal accessories when installing this repeater. 7. Notice: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables. 8. Notice: Check all cables for shorts and opens. Verify that there are no cables with loose or poor connections. RF leakage could cause oscillation to occur under some conditions. 9. Notice: If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. The specifications for stationary use of the Unit must not be exceeded. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Unit. 10. Notice: A spacing of 40 mm (1.58 inch) around the unit is required. Specified torques must be observed for certain mounting procedures according to the following table:
Pins Type Thread Specified torques M 6 3.3 Nm Hex nuts M 6 3.3 Nm Screws M6 3.3 Nm table Specified torques 1.2. ELECTRICAL INSTALLATION 1.2.1. Health and Safety for Electrical Installation Read and observe chapter 1.3 Health and Safety. 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 1.2.2. Property Damage Warnings for Electrical Installation 1. Attention: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 2. Attention: If the mains connector of the PSR is not easily accessible, a disconnect device in the mains power circuit must be provided within easy reach. 3. Attention: A connection of the mains supply to a power socket requires the power socket to be nearby the PSR. 4. Attention: Before connecting or disconnecting the mains connector at the PSR, ensure that mains power supply is disconnected. 5. Attention: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by IEC/EN60950-1) and an overcurrent limiting device are connected between mains power and the PSR. 6. Attention: Incorrectly wired connections can destroy electrical and electronic components. 7. Notice: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V
(see electrochemical contact series). 8. Notice: Use an appropriate torque wrench for the coupling torques:
for 4.3-10 type connectors (5 Nm, 44 in lb) with 22mm (7/8) in opening, e.g. item no. TW-4310 Do NOT use your hands or any other tool (e.g. a pair of pliers). This might cause damage to the connector and lead to a malfunction of the PSR. 9. Notice: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised. 10. Notice: Observe the labels on the front panels before connecting or disconnecting any 11. Notice: Unused connectors must be closed with their protective covers to ensure water cables. tightness. 1.3. HEALTH AND SAFETY 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 3. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the units inner conductor of the antenna port(s). Disconnect mains before connecting or replacing antenna cables. 4. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the antenna(s) connected to the unit. Implement prevention measures to avoid the possibility of close proximity to the antenna(s) while in operation. 1.3.1. Property Damage Warnings 1. Attention: Due to power dissipation, the psr may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. 2. Attention: Only authorized and trained personnel are allowed to open the unit and get access to the inside. 3. Notice: Although the PSR is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the PSR for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 4. Notice: ESD precautions must be observed. Before commencing maintenance work, use the available grounding (earthing) system to connect ESD protection measures. 5. Notice: Only suitably qualified personnel are allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 6. Notice: Keep operating instructions within easy reach and make them available to all users. 7. Notice: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. 8. Notice: Only license holders for the respective frequency range are allowed to operate this unit. 9. Do not disassemble the unit. 10. Notice: Make sure the repeater settings are correct for the intended use (refer to the manufacturer product information) and regulatory requirements are met. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer. 1.3.2. Compliance 1. Notice: For installations, which have to comply with FCC RF exposure requirements, the antenna selection and installation must be completed in a way to ensure compliance with those FCC requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss between the repeater and antenna, the minimum distance D to be maintained between the antenna location and human beings is calculated according to this formula:
where P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in addition to the antenna gain minus the loss between the repeater and the antenna. PD (mW/cm) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general population / uncontrolled exposures which is o o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz 1 for frequencies from 1500MHz to 100,000MHz RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 2. Notice: For installations which have to comply with European EN50385 exposure compliance requirements, the following Power Density limits/guidelines (mW/cm) according to ICNIRP are valid:
o o o 0.2 for frequencies from 10 MHz to 400 MHz F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz 1 for frequencies from 2 GHz to 300 GHz 3. Notice: Installation of this equipment is in full responsibility of the installer, who has also the responsibility, that cables and couplers are calculated into the maximum gain of the antennas, so that this value, which is filed in the FCC Grant and can be requested from the FCC data base, is not exceeded. The industrial boosters are shipped only as a naked booster without any installation devices or antennas as it needs for professional installation. 4. Notice: For installations which have to comply with FCC/ISED requirements:
English:
This device complies with FCC Part 15. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Health Canadas Safety Code 6. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas http://www.hc-sc.gc.ca/ewh-
requirement. semt/pubs/radiation/radio_guide-lignes_direct-eng.php. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Information obtained can be at
]/[][][24cmmWmWcmPDPD=
Antenna Stmt for ISED:
This device has been designated to operate with the antennas having a maximum gain of 9 dBi. Antennas having a gain greater than 9 dBi are prohibited for use with this device without consent by ISED regulators. The required antenna impedance is 50 ohms. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance (as specified in table 1: Antenna Distances) from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. French:
Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Les informations peuvent tre obtenues: http://www.hc-sc.gc.ca/ewh-
semt/pubs/radiation/radio_guide-lignes_direct-fra.php Antenne Stmt pour ISDE:
Ce dispositif a t dsign pour fonctionner avec les antennes ayant un gain maximal de 9 dBi. Antennes ayant un gain plus grand que 9 dBi sont interdites pour une utilisation avec cet appareil sans le consentement des organismes de rglementation dISDE. Limpdance dantenne requise est 50 ohms. Lantenne (s) utilis pour cet metteur doit tre install pour fournir une distance de sparation minimale (comme indiqu dans la table 1) par rapport toute personnes et ne doit pas tre co-localises ou oprant en conjonction avec une autre antenne ou metteur. Les utilisateurs et les installateurs doivent tre fournis avec des instructions dinstallation de lantenne et des conditions de fonctionnement de lmetteur pour satisfaire la conformit aux expositions RF. 5. Notice: The unit complies with Overvoltage Category II. It also complies with the surge requirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection (external surge protection) is recommended depending on the individual application in order to avoid damage caused by overcurrent. For Canada and US, components used to reduce the Overvoltage Category shall comply with the requirements of IEC 61643-series. As an alternative, components used to reduce the Overvoltage Category may comply with ANSI/IEEE C62.11, CSA Certification Notice No. 516, CSA C22.2 No. 1, or UL 1449. Suitability of the component for the application shall be determined for the intended installation. 6. Notice: Corresponding local particularities and regulations must be observed. 7. Note: For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 8. Note: For a Class B digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Connect the equipment into an outlet on a circuit different from that to which the receiver Increase the separation between the equipment and receiver. is connected.
- Consult the dealer or an experienced RF technician for help. 9. Note: This unit complies with European standard EN62368-1. Equipment Symbols Used / Compliance Please observe the meanings of the following symbols used in our equipment and the compliance warnings:
Symbol Compliance Meaning / Warning For industrial (Part 90) signal booster, Class B:
This is a 90.219 Class B device. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-
boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. For industrial (Part 90) signal booster, Class A:
This is a 90.219 Class A device. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-
boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED licensee to operate this device. AVERTISSEMENT: Ce produit NEST PAS un appareil de CONSOMMATION. Il est conu pour tre install par un installateur approuv par un titulaire de licence dISDE. Pour utiliser cet appareil, vous DEVEZ dtenir une LICENCE dISDE ou avoir obtenu le consentement exprs dun titulaire de licence autoris par ISDE. To be sold exclusively to mobile operators or authorized installers no harmonized frequency bands, operation requires license. Intended use:
EU and EFTA countries Indicates conformity with the RED directive 2014/53/EU and/or RoHS directive 2011/65/EU.
FCC
ISED CE CE Indicates conformity with the RED directive 2014/53/EU and RoHS directive 2011/65/EU certified by the notified body no. 0700. Required Antenna Distances Model Antenna gain without cable loss [dBi]
Maximum Distance DL Maximum Distance UL FCC ISED FCC ISED m inches m inches m inches m inches PSR 700/800 9 0.687 27.05 0.999 39.33 0.345 13.58 0.502 19.76 Table 1: Antenna Distances WEEE Recycling Country specific information about collection and recycling arrangements per the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations is available on CommScopes website. http://www.commscope.com/About-Us/Corporate-Responsibility-and-Sustainability/Environment/#recycling
1 2 3 | Users Manual | Users Manual | 3.04 MiB | April 28 2021 |
Users Manual Public Safety Repeaters PSR 700/800 MF0123A1F DISCLAIMER:
This document has been developed by CommScope and is intended for the use of its customers and customer support personnel. The information in this document is subject to change without notice. While every effort has been made to eliminate errors, CommScope disclaims liability for any difficulties arising from the interpretation of the information contained herein. The information contained herein does not claim to cover all details or variations in equipment, nor to provide for every possible incident to be met in connection with installation, operation, or maintenance. This document describes the performance of the product under the defined operational conditions and does not cover the performance under adverse or disturbed conditions. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchasers purposes, contact CommScope. CommScope reserves the right to change all hardware and software characteristics without notice. COPYRIGHT:
Copyright 2021 CommScope Inc. All Rights Reserved. This document is protected by copyright. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical photocopying, recording, or otherwise without the prior written permission of CommScope. TRADEMARKS All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope. Names of products mentioned herein are used for identification purposes only and may be trademarks and / or registered trademarks of their respective companies. Andrew Wireless Systems GmbH, 15-April-2021 Page 2 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Table of Contents TABLE OF CONTENTS 1. GENERAL USED ABBREVIATIONS HEALTH AND SAFETY PROPERTY DAMAGE WARNINGS COMPLIANCE ABOUT COMMSCOPE CONTACTING COMMSCOPE CommScope Mobility Solutions (CMS) Technical Support Accessing DCCS User Documentation Technical Training 2. INTRODUCTION PURPOSE PSR 700/800 MHZ 0.5/2W 3. FUNCTIONAL DESCRIPTION 4. COMMISSIONING MECHANICAL INSTALLATION Health and Safety for Mechanical Installation Property Damage Warnings for Mechanical Installation Wall Mounting Procedure ELECTRICAL INSTALLATION Health and Safety for Electrical Installation Property Damage Warnings for Electrical Installation Connections Grounding (Earthing) Connection of the Antenna Cables Cleaning Procedure for RF Cable Connectors Antenna Cable Connector Assembly PSR Alarms Connection LAN Connection Power Connection 5. SETTING UP THE WEB GUI LAN SETTINGS AT LOCAL PC NETWORK MANAGEMENT REQUIREMENTS EULA ACCEPTANCE PAGE LOGIN PAGE MAIN PAGE 1.1. 1.2. 1.3. 1.4. 1.5. 1.6. 1.6.1. 1.6.2. 1.6.3. 2.1. 2.2. 4.1. 4.1.1. 4.1.2. 4.1.3. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 5.1. 5.2. 5.3. 5.4. 5.5. 6 6 7 7 8 12 13 13 13 13 14 14 14 15 17 17 17 18 19 22 22 22 23 23 24 25 27 29 31 32 34 34 35 35 36 36 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 3 Table of Contents 6. STATUS LEDS, PSR ALARMS, AND TROUBLESHOOTING 5.6. 5.6.1. 5.6.2. 5.6.3. 5.6.4. 5.6.5. 5.6.6. 5.6.7. 5.6.8. 5.6.9. 5.6.10. 5.6.11. 5.6.12. 5.6.13. 5.6.14. 5.6.15. 5.7. 5.7.1. 5.7.2. 5.7.3. 5.7.4. 5.7.5. 5.7.6. 5.7.7. 7.1. 7.2. 7.3. 8.1. 8.2. 8.3. 8.3.1. 8.3.2. 8.3.3. 8.3.4. 8.4. 8.5. SYSTEM SETTINGS License Upgrade Software Upgrade Restore Factory Defaults My Account Management IP Settings OMC Connection Alarm Settings General RF Setting Channelized ALC (Class A Only) 700 MHz Channels (Class A Only) 800 MHz Channels (Class A Only) Digital Channels (Class B mode) Site Location Time and Date Summary SYSTEM OPERATION Active Alarm Alarm History Event History Antenna Isolation Check VSWR Check and Donor Calibration 700MHz Band Overview 800MHz Band Overview 7. MAINTENANCE GENERAL RESET TO FACTORY DEFAULTS CLEANING THE HEAT SINK 8. APPENDIX BBU/UPS REQUIREMENTS ILLUSTRATIONS SPECIFICATIONS RF Performance Mechanical Specifications Power Specifications Environmental and Safety Specifications SPARE PARTS 9. LIST OF CHANGES 10. INDEX Page 4 AVAILABLE CONFIGURATIONS AND SW FEATURE KEYS MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 37 37 38 39 40 41 42 43 44 45 45 46 47 48 48 49 50 50 51 52 53 53 54 54 55 56 56 57 58 59 59 59 62 62 64 64 65 65 66 67 68 Figures and Tables FIGURES AND TABLES figure 3-1 System overview example of a PSR 700/800 MHz .................................. 15 figure 3-2 Configuration of a PSR 700/800 MHz 0.5/2W, analogue variant .............. 16 figure 3-3 Configuration of a PSR 700/800 MHz 0.5/2W, digital variant ................... 16 figure 4-1 Connectors of PSR 700/800 MHz ............................................................. 23 figure 4-2 Grounding bolt (left) and schematic view (right) ....................................... 23 figure 4-3 PSR alarms cable ..................................................................................... 29 figure 4-4 AC wires, installation example .................................................................. 32 figure 4-5 DC wires, installed .................................................................................... 33 figure 7-1 Location of Control Board ......................................................................... 57 figure 7-2 Reset button on Control Board ................................................................. 57 figure 8-1 External configuration ............................................................................... 59 figure 8-2 Cabinet measurements ............................................................................ 60 figure 8-3 Cabling plan (with BBU for DC installations) ............................................ 61 table 1-1 Required antenna distances ...................................................................... 10 table 4-1 Specified torques ....................................................................................... 18 table 4-2 Accessories for wall mounting ................................................................... 19 table 4-3 Power supply connection (AC) .................................................................. 32 table 6-1 Status LED indication and troubleshooting ................................................ 55 table 8-1 Digital filters (narrowband) for Class A repeaters ...................................... 63 table 8-2 Digital filters (broadband) for Class A repeaters ........................................ 63 table 8-3 Selectable passbands for class B repeaters .............................................. 63 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 5 1. General 1. General 1.1. Used Abbreviations AC/DC AHJ AIMOS ALC Alternating current / Direct Current Authority Having Jurisdiction Andrew Integrated Management and Operating System Automatic Level Control Battery Backup Unit Built-In Test Equipment Base Transceiver Station
"Conformit Europenne" ("European Conformity") Compact Disk Code of Federal Regulations Downlink Declaration of Conformity EDGE EN ESD ETS EULA Enhanced Data Rates for GSM Evolution European Norm Electrostatic Discharge European Telecommunication Standard End User License Agreement Global System for Mobile Communication Ground Graphical User Interface Intercept Point 3rd order Identification Number Intelligent Optical Network Ingress Protection Innovation, Sciences et Dveloppement conomique Canada Innovation, Science and Economic Development Canada; formerly IC / Industry Canada International Organization for Standardization Light Emitting Diode Local Maintenance Terminal Long Term Evolution Multiple Input Multiple Output Mobile Station Main Unit National Electrical Code for the United States Noise Figure The National Fire Protection Association Packing Gland Passive Intermodulation Public Safety Repeater Radio & Telecommunications Terminal Equipment Radio Frequency Receiver Simple Network Management Protocol Transmitter Uplink / Underwriter Laboratories Universal Mobile Telecommunication System Uninterruptible Power Supply United States of America WCDMA Wideband Code Division Multiple Access WDM Wavelength Division Multiplex MF0123A1F_FCC_uc Manual for PSR 700/800 MHz BBU BITE BTS CE CD CFR DL DoC GSM GND GUI ICP3 ID No ION IP ISDE ISED ISO LED LMT LTE MIMO MS MU NEC NF NFPA PG PIM PSR R&TTE RF RX SNMP TX UL UMTS UPS US Page 6 1. General WEEE Waste Electrical and Electronic Equipment (Directive) 1.2. Health and Safety 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 3. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the units inner conductor of the antenna port(s). Disconnect mains before connecting or replacing antenna cables. 4. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the antenna(s) connected to the unit. Implement prevention measures to avoid the possibility of close proximity to the antenna(s) while in operation. 1.3. Property Damage Warnings 1. Attention: Due to power dissipation, the PSR (Public Safety Repeater) may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. 2. Attention: Only authorized and trained personnel are allowed to open the unit and get access to the inside. 3. Notice: Although the PSR is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the PSR for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 4. Notice: ESD precautions must be observed. Before commencing maintenance work, use the available grounding (earthing) system to connect ESD protection measures. 5. Notice: Only suitably qualified personnel are allowed to work on this unit and only installation, operation and familiar with all safety notices, after becoming maintenance procedures contained in this manual. 6. Notice: Keep operating instructions within easy reach and make them available to all users. 7. Notice: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 7 1. General 8. Notice: Only license holders for the respective frequency range are allowed to operate this unit. 9. Notice: Do not disassemble the unit. 10. Notice: Make sure the repeater settings are correct for the intended use (refer to the manufacturer product information) and regulatory requirements are met. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer. 1.4. Compliance 1. Notice: For installations, which have to comply with FCC RF exposure requirements, the antenna selection and installation must be completed in a way to ensure compliance with those FCC requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss between the repeater and antenna, the minimum distance D to be maintained between the antenna location and human beings is calculated according to this formula:
where P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in addition to the antenna gain minus the loss between the repeater and the antenna. PD (mW/cm) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general population / uncontrolled exposures which is o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz o 1 for frequencies from 1500MHz to 100,000MHz RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 2. Notice: For installations which have to comply with European EN50385 exposure compliance requirements, the following Power Density limits/guidelines (mW/cm) according to ICNIRP are valid:
0.2 for frequencies from 10 MHz to 400 MHz o o F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz o 1 for frequencies from 2 GHz to 300 GHz 3. Notice: Installation of this equipment is in full responsibility of the installer, who has also the responsibility, that cables and couplers are calculated into the maximum gain of the antennas, so that this value, which is filed in the FCC Grant and can be requested from the FCC data base, is not exceeded. The industrial boosters are shipped only as a naked booster without any installation devices or antennas as it needs for professional installation. 4. Notice: Installation environment: Although this unit is fully designed for proper operation in a location not protected from the weather, the intended installation location is a dry room with an ambient temperature of about 25C (77F). Page 8 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz
]/[][][24cmmWmWcmPDPD=1. General 5. Notice: For installations which have to comply with FCC requirements:
This device complies with FCC Part 15. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Information http://www.hc-sc.gc.ca/ewh-
at semt/pubs/radiation/radio_guide-lignes_direct-eng.php. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. obtained can be 6. Notice: The unit complies with Overvoltage Category II. It also complies with the surge requirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection
(external surge protection) is recommended depending on the individual application in order to avoid damage caused by overcurrent. For Canada and US, components used to reduce the Overvoltage Category shall comply with the requirements of IEC 61643-series. As an alternative, components used to reduce the Overvoltage Category may comply with ANSI/IEEE C62.11, CSA Certification Notice No. 516, CSA C22.2 No. 1, or UL 1449. Suitability of the component for the application shall be determined for the intended installation. 7. Notice: Corresponding local particularities and regulations (in particular, National Electrical Code NFPA 70, Fire Code NFPA 1, Life Safety Code NFPA 101, International Fire Code) must be observed. 8. Note: For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 9. Note: Class B broadband operations that include the ESMR frequency bands 817-
824 MHz and 862-869 MHz are permitted only when installed indoors due to section 90.219(d)(7) of the FCC rules which says: Except for distributed antenna systems
(DAS) installed in buildings, the passband of a [Part 90] Class B booster should not encompass both commercial services (such as ESMR and Cellular Radiotelephone) and part 90 Land Mobile and Public Safety Services. 10. Note: Follow the Good Engineering Practices and be a Good RF Neighbor:
Good engineering practice must be used in regard to the signal boosters noise radiation. Accordingly, the gain of the signal booster should be set so that the ERP of the output noise from the signal booster should not exceed the level of -43 dBm in 10 kHz measurement bandwidth. In the event that the noise level measured exceeds that value, the signal booster gain should be decreased accordingly. Also, please note that in general, the ERP of noise on a spectrum more than 1 MHz outside of the pass band should not exceed -70 dBm in a 10 kHz measurement bandwidth. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 9 1. General 11. Note: For a Class B digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Connect the equipment into an outlet on a circuit different from that to Increase the separation between the equipment and receiver. which the receiver is connected.
- Consult the dealer or an experienced RF technician for help. 12. Note: This unit complies with European standard EN62368-1. 13. Note: The complete ERRC (Emergency Responder Radio Coverage) system is only compliant with UL 2524 if all devices connected to the PSR, such as the battery backup unit and the dedicated annunciator, comply with UL 2524 as well. Required Antenna Distances This system is a RF Transmitter and continuously emits RF energy. Maintain a minimum clearance from the antenna as specified in the table below while the system is operating. Whenever possible, power down the unit before servicing the antenna. Model Minimum Distance DL Minimum Distance UL Antenna gain without cable loss [dBi]
9 table 1-1 Required antenna distances inches 27.05 m 0.687 FCC FCC m 0.345 inches 13.58 PSR 700/800 WEEE Recycling Do not put the units into the garbage but dispose of them properly according to local and/or regional regulations. Country specific information about collection and recycling arrangements per the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations is available on CommScopes website. http://www.commscope.com/About-Us/Corporate-Responsibility-and-Sustainability/Environment/#recycling Page 10 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 1. General Equipment Symbols Used / Compliance Please observe the meanings of the following symbols used in our equipment and the compliance warnings:
Symbol Compliance Meaning / Warning register For industrial (Part 90) signal booster, Class A or B:
This is a 90.219 Class A or B device. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. This booster can be configured as a Class A or Class B signal booster. If configured as Class B signal Booster (as defined in 47 CFR 90.219), you the signal booster online at MUST www.fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. For industrial (Part 90) signal booster, Class B:
This is a 90.219 Class B device. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. To be sold exclusively to mobile operators or authorized installers no harmonized frequency bands, operation requires license. Intended use: EU and EFTA countries Indicates conformity with the RED directive 2014/53/EU and/or RoHS directive 2011/65/EU. Indicates conformity with the RED directive 2014/53/EU and RoHS directive 2011/65/EU certified by the notified body no. 0700.
FCC CE CE MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 11 1. General 1.5. About CommScope CommScope is the foremost supplier of one-stop, end-to-end radio frequency (RF) solutions. Part of the CommScope portfolio are complete solutions for wireless infrastructure from top-of-the-tower base station antennas to cable systems and cabinets, RF site solutions, signal distribution, and network optimization. For patents see www.cs-pat.com. CommScope has global engineering and manufacturing facilities. In addition, it maintains field engineering offices throughout the world. Andrew Wireless Systems GmbH based in Buchdorf/Germany, which is part of CommScope, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage and capacity solution for wireless networks in both indoor installations and outdoor environments, e.g. tunnels, subways, in-trains, airport buildings, stadiums, skyscrapers, shopping malls, hotels and conference rooms. Andrew Wireless Systems GmbH operates a quality management system in compliance with the requirements of ISO 9001 and TL 9000. All equipment is manufactured using highly reliable material. To maintain highest quality of the products, comprehensive quality monitoring is conducted at all fabrication stages. Finished products leave the factory only after a thorough final acceptance test, accompanied by a test certificate guaranteeing optimal operation. Hereby Andrew Wireless Systems declares that the radio equipment type Repeater is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available from CommScope. According to the DoC, our CE-marked equipment can be used in all member states of the European Union. To make the most of this product, we recommend you carefully read the instructions in this manual and commission the system only according to these instructions. For technical assistance and support, please refer to the CMS Technical Support contact information in the next chapter. Page 12 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 1. General 1.6. Contacting CommScope 1.6.1. CommScope Mobility Solutions (CMS) Technical Support For additional information, please contact CMS Technical Support:
Telephone Helplines: Call one of the Telephone Helpline numbers listed below to get live support, 24 hours a day. Global 24X7
+1 888-297-6433
(Toll free for U.S. and Canada) EMEA 8:00-17:00 (UTC +1)
+ 800 73732837
(Toll free for parts of EMEA and Australia)
+ 49 909969333
(Toll charge incurred) Calls to an EMEA Helpline outside of the 8:00 to 17:00 time frame will be forwarded to the 24x7 Helpline. Online Support: Click on the following URL link to submit tickets using the online CMS Technical Support Form:
http://www.commscope.com/wisupport Alternatively, enter the preceding URL into your web browser, and then press ENTER on your keyboard or scan the QR code. 1.6.2. Accessing DCCS User Documentation To access the Customer Portal of DCCS (Distributed Coverage and Capacity Solutions), scan the QR Code to the right or go to http://www.commscope.com/membership. Follow the prompts and click DCCS to open the site. A user account and password are required. Please register for an account if you dont have one. Once you have access, click to select a product line link to access the documentation for that product. 1.6.3. Technical Training To access the CommScope University Training site, please use the following web address http://www.commscopeuniversity.com or scan the QR code to the right. Both online and classroom training are available. Instructor-led courses are conducted in North America and Europe. Before choosing a course, please verify the region. For training related questions, please contact us:
Americas: DASTrainingUS@CommScope.com EMEA: DASTrainingEMEA@CommScope.com MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 13 2. Introduction 2. Introduction 2.1. Purpose This manual contains information and procedures for the operation of the CommScope Public Safety Repeaters PSR 700/800 MHz 0.5/2W Class A and Class B. The purpose of this document is to provide a step-by-step procedure to help experienced technicians or engineers install and commission an in-building wireless enhancement system using CommScope repeaters. Follow the instructions in this guide to minimize risks associated with modifying a live system and preclude service interruptions. This document assumes the technician or engineer understands the basic principles and functionality involved with repeater and in-building systems. This guide has been written to address the practical concerns of the installer. 2.2. PSR 700/800 MHz 0.5/2W This pick-up repeater comes in two variants, one is a digital, channelized Class A repeater and the second is an analogue Class B repeater. Both can be used stand-
alone or in combination with an ERA system. They are designed to cover the 700 and 800 MHz public safety bands and can be used to establish a wireless connection between a BTS and a passive or active DAS. Via feature keys, this repeater can be configured as a single- or dual-band version with an output power of 0.5 W or 2 W per band. With its battery backup support (only available in combination with a BBU/UPS), UL Type 4X housing, dry alarm contacts and its integrated oscillation detection and healing mechanism, a fully NFPA 1221 and IFC compliance can be guaranteed. The implemented channel-based muting functionality prevents desensitization of the BTS by switching off UL channels without traffic. The class A variant supports up to 32 channels in a range between 12.5 kHz and 75 kHz, where every channel can be muted while no traffic is active. A detailed filter description can be found in table 8-1 and table 8-2. With the class B variant, the operator can choose between 3, 10 and 18 MHz pass band bandwidths, where every pass band can be muted while no traffic is active. Features at a glance UL 2524, NFPA 1221 and IFC compliant Compact, high-performance, economical public safety signal source Complies with relevant public safety specifications High performance digital programmable architecture supports up to 32 channels per band with .5W and 2W power output Automatic Gain Control (AGC) and channelized uplink squelch ensure clear voice Output power and band capacity can be field-upgraded via license key (see chapters transmission 5.6.1 and 8.4) Web-based GUI and SNMP support for intelligent configuration and monitoring Page 14 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 3. Functional Description 3. Functional Description The following figure shows an example of a PSR 700/800 MHz integrated into a possible network setup. The Annunciator and Battery Backup Unit (BBU)* depicted in this illustration are only examples (for DC installations) since they are not provided by CommScope and may look differently in the actual setup. For AC installations, a UPS*
has to be used instead of a BBU. figure 3-1 System overview example of a PSR 700/800 MHz
[1] The usage of the individual connectors is described in chapter 4.2.3.
[2] For the connection of the alarm cable, see chapter 4.2.8.
[3] For the connection of the power cable (not part of the delivery), see chapter 4.2.10.
* Note: For the BBU/UPS observe the requirements specified in chapter 8.1. The block diagrams on the next page illustrate signal processing taking place inside the PSR 700/800 MHz, both for the analogue and digital variant. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 15 3. Functional Description figure 3-2 Configuration of a PSR 700/800 MHz 0.5/2W, analogue variant figure 3-3 Configuration of a PSR 700/800 MHz 0.5/2W, digital variant Page 16 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning 4. Commissioning Read and observe the health, safety, and property damage warnings as well as the description carefully to avoid mistakes and proceed step-by-step as described. Attention: Do not operate the PSR without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load. Notice: Only qualified personnel should carry out the electrical, mechanical, commissioning, and maintenance activities that require the unit to be open. Ensure that all connections have been performed according to chapter 4.2.3 Connections. To safeguard correct operation, a device that guarantees uninterruptible power supply (e.g. an appropriate BBU/UPS) has to be connected to the PSR (see chapter 4.2.10). Unless otherwise agreed to in writing by CommScope, CommScopes general limited product warranty (http://www.commscope.com/Resources/Warranties/) shall be the warranty governing the PSRs, including the installation, maintenance, usage and operation of the PSRs. 4.1. Mechanical Installation 4.1.1. Health and Safety for Mechanical Installation Caution: Risk of injury by the considerable weight of the unit falling. Ensure there is adequate manpower to handle the weight of the system. Caution: Risk of serious personal injury by equipment falling due to improper installation. The installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components. The screws and dowels (wall anchors) used should also be appropriate for the structure of the supporting wall. Caution: Explosive atmospheres. To avoid explosion or fire, do not operate this equipment in the presence of flammable gases or fumes. Caution: Lightning danger. Do not install or make adjustments to this equipment during an electrical storm. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 17 4. Commissioning 4.1.2. Property Damage Warnings for Mechanical Installation 1. Attention: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. Otherwise, the lifespan and performance of the repeater may be reduced. 2. Attention: Due to power dissipation, the unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 3. Attention: The repeater must be installed in a vertical position. 4. Notice: Exceeding the specified load limits may cause the loss of warranty. 5. Notice: Do not place cables or tools that may damage the repeater in close proximity to it. 6. Notice: Do not wear jewelry or metal accessories when installing this repeater. 7. Notice: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables. 8. Notice: Check all cables for shorts and opens. Verify that there are no cables with loose or poor connections. RF leakage could cause oscillation to occur under some conditions. 9. Notice: If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. The specifications for stationary use of the Unit must not be exceeded. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Unit. 10. Notice: A spacing of 300 mm (11.81 inch) around the unit is required. Specified torques must be observed for certain mounting procedures according to the following table:
Type Thread Specified torques Pins M6 Hex nuts M6 3.3 Nm / 29.2 in lb Screws M6 table 4-1 Specified torques Page 18 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning 4.1.3. Wall Mounting Procedure Before starting the procedure, read and observe all warnings and notices in chapters 4.1.1 and 4.1.2. You will need the following contents of the accessory kit for installation:
Part M6*50mm tapping screws Washer DIN 126 M6 Nut / Washer Number of parts 5 5 2/2 Used for Fastening the bracket to the wall
(only four of each are required) Fastening the bolts (one per side) table 4-2 Accessories for wall mounting Notice: For the four M6*50mm tapping screws, you will also need four appropriate screw anchors (one for each screw) that are not part of the delivery as the anchor type is dependent on the on-site conditions (wall structure and materials). Use screw anchors that are rated for the mounting surface. The PSR is installed in the wall mounting bracket for delivery and must be removed for the mounting procedure. The easiest way to do this, is to place the assembly on the floor or a low table with the PSR cover facing downwards and the mounting bracket on top as shown below. When you do so, make sure to provide a smooth surface (e.g. by laying a soft cloth underneath) so that the cover is not scratched or damaged in the process. Then, use an M6 Phillips (cross recess) screwdriver to loosen the six screws
(3 per side) by which the PSR is fastened to the bracket. Make sure to keep these screws as they will be required again:
Then, take the bracket off but take care not to damage the threads of the bolts at the PSR (one at each side), which serve to hang the unit on the bracket later. Also take care not to lose the two clips around the bolts (one at each side) which serve to ease positioning of the unit when inserting it back into the bracket. If a clip falls off, keep it for later use. When the unit has been removed, the bracket can be installed on the wall as explained in the following. Use the bracket as a template to mark the positions of the four drill holes at the mounting surface / wall:
MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 19 4. Commissioning At the four positions marked with the bracket as the template, drill four holes into the wall using a drill bit that matches the thickness of the M6 wall anchors (not part of the delivery; see Notice under table 4-2). Then, insert each of the four wall anchors into the holes:
Gently tap the wall anchors with a hammer to fully insert them into the wall. While holding the bracket in place, insert the four M6 x 40 mm tapping screws into the wall anchors and tighten them to fasten the bracket to the wall. Confirm that the bracket is securely fastened before moving to the next step. When the bracket is securely fastened to the wall, insert the PSR into the bracket by positioning the two bolts (one at each side) in the corresponding grooves of the bracket. Also, reinstall the positioning clips in case they fell off before:
Page 20 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning Notice: When positioning the PSR in the bracket, be careful not to damage the threads of the bolts by pushing or pulling the unit too hard in the process. When the PSR is correctly positioned, fasten the unit again with the six M6 screws that you unscrewed before (three at each side) using the M6 Phillips (cross recess) screwdriver:
Finally, use a standard 10 mm wrench (or open-ended wrench) to fasten the bolts with the M6 washers and nuts of the accessory kit:
MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 21 4.2. Electrical Installation 4. Commissioning 4.2.1. Health and Safety for Electrical Installation Read and observe chapter 1.2 Health and Safety. 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 4.2.2. Property Damage Warnings for Electrical Installation 1. Attention: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 2. Attention: The BBU/UPS must be installed within easy reach and it must be equipped with a disconnect device. 3. Attention: Before connecting or disconnecting the BBU at/from the PSR, ensure that the BBU/UPS is not connected to the mains power supply. 4. Attention: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by NEC, NFPA 70) and an overcurrent limiting device are connected between mains power and the PSR. 5. Attention: Incorrectly wired connections can destroy electrical and electronic components. 6. Notice: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 7. Notice: Use an appropriate torque wrench for the coupling torques:
for 4.3-10 type connectors (5 Nm, 44 in lb) with 22mm (7/8) in opening, e.g. item no. TW-4310 Do NOT use your hands or any other tool (e.g. a pair of pliers). This might cause damage to the connector and lead to a malfunction of the PSR. 8. Notice: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised. 9. Notice: Observe the labels on the front panels before connecting or disconnecting any cables. watertightness. 10. Notice: Unused connectors must be closed with their protective covers to ensure 11. Check all cables for shorts and opens. Verify that there are no cables with loose or poor connections. RF leakage could cause oscillation to occur under some conditions. Page 22 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning 4.2.3. Connections Access for mains con-
nection, e.g. for BBU /
UPS (not part of delivery) DO NOT USE Measurement probe for donor antenna *
Connector for donor antenna Measurement probe *
for coverage antenna LAN/Ethernet connector figure 4-1 Connectors of PSR 700/800 MHz
* Note: Whenever they are not used, the measurement probes must be terminated with Connector for coverage antenna Connector for alarm cable the (golden) SMA terminations. 4.2.4. Grounding (Earthing) Grounding must be carried out. Connect an earth-bonding cable to the grounding bolt inside the PSR. To get access to the grounding bolt, the front door must be opened by unlocking both locks at the left side of the cabinet with the supplied key. To the feed grounding cable into the housing through this opening, remove the plastic cap. available The 1/2 common thread can be used to connect conduit. The PSR is designed to operate under AC (89-264 VAC), DC (-62 to -34 VDC) / max load 160W. A Ground wire needs to be connected correctly without removing or changing the Ground lug of the supply conductors:
PSU GND cable, pre-
installed by supplier:
Unscrew and remove it;
install the local GND cable; then connect it again on top of the local GND cable. Local power cable GND, to be connected by installer between the PSR cabinet and the pre-installed PSU GND cable (which must be unscrewed first so that it will be located on top). figure 4-2 Grounding bolt (left) and schematic view (right) After loosening the M4 hexagon nut, connect the ring terminal of the earth-bonding cable to the grounding bolt as illustrated above. Then, fasten all parts again with the M4 hexagon nut. Do not use the grounding connections to connect external devices. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 23 4. Commissioning Note: Ground of a second unit has to be connected to the same equipotential bonding terminal as the repeater. Use bonding cables of the same length, as short as possible and with a large wire cross section. Follow local electrical code practices. 4.2.5. Connection of the Antenna Cables The PSR has 4.3-10-type antenna connector. Please refer to section 4.2.3 for its location. Refer to the corresponding documentation of the connector manufacturer for mounting the cable connectors. The bending radius of the antenna cables must remain within the given specifications. Choose the type of cable best suited for the antenna. Consider that a cable with higher loss is less expensive but impairs performance. Notice: Use an appropriate torque wrench for the coupling torques:
for 4.3-10 type connectors (5 Nm, 44 in lb) with 22 mm (7/8) in opening, e.g. item no. TW-4310
Do NOT use your hands or any other tool (e.g. a pair of pliers)! This might cause damage to the connector and lead to a malfunction of the signal booster. Attention: To minimize passive inter-modulation (PIM) distortion, attention has to be paid to the physical condition of the connector junctions:
Do not use connectors that show signs of corrosion on the metal surface. Prevent the ingress of water or dirt into the connector. Use protective caps for the connectors when not mounted. Before mounting clean the connectors with dry compressed air. Before mounting clean the mating surfaces of the connector with a lint-free alcohol-drenched cloth on a wooden or non-metallic item. Attach and torque the connectors properly. Avoid metallic abrasion when mounting the connectors by only screwing the connecting nut, but not turning the whole connector. Use a torque wrench to fasten the connector, see above. Clean the protective caps before mounting for antenna cable replacement. Note: To use the integrated Donor Antenna Disconnection Alarm (required by UL2524), the antenna and antenna cable must fulfill special requirements;
see chapter 5.7.5 VSWR Check and Donor Calibration for details. Page 24 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning 4.2.6. Cleaning Procedure for RF Cable Connectors The figures in this chapter illustrate the cleaning procedure and do not show the actual unit. 1. What is needed for the cleaning?
a. Isopropyl alcohol b. Compressed air c. Lint-free wipe d. Cotton buds 2. Remove protective cap from the RF connector. Caution: Risk of injury by flying particles when compressed air is used. Wear protective clothing, especially protective glasses. 3. Remove metal chips and small particles from the mating and inner surfaces of the connector using compressed air. Warning: Flammable material. Risk of fire. Keep away from sources of ignition. Caution: Eye irritant product. Risk of eye irritation. Avoid contact with eyes and skin. Wear protective clothing, especially protective glasses. 4. Clean the connector winding with lint-free wipe drenched with isopropyl alcohol. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 25 4. Commissioning 5. Clean the lip of the inner ring with a cotton bud drenched with isopropyl alcohol. 6. Clean the inside surface of the inner ring with a cotton bud drenched with isopropyl alcohol. 7. Clean the inside of the center conductor spring tines with a cotton bud drenched with isopropyl alcohol. 8. Clean in the similar way the connector of the connected cable. Remove protective caps from the unit connector first. 9. Remove metal chips and small particles from the mating and inner surfaces of the connector using compressed air. Page 26 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning 10. Continue with the winding area using lint-free wipe drenched with isopropyl alcohol. 11. Continue with the inside mating surface of the inner ring. 12. Clean the outside surface of the center pin. 4.2.7. Antenna Cable Connector Assembly The figures in this chapter illustrate the connection procedure and do not show the actual unit. 1. What is needed for the connector assembly?
a. Torque wrench. b. (Adjustable) counter wrench MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 27 4. Commissioning 2. Join the connectors and turn the coupling nut until the thread grips. 3. Push in the connector until it clicks. 4. Fasten the coupling nut hand-tight. Do not turn the connector but the coupling nut only. Torque wrench 5. Retain the cable connector with the counter wrench and fasten the coupling nut with the torque wrench until the torque is applied (torque wrench clicks). For angled antenna connectors use your hand to retain the cable connector and fasten the coupling nut with the torque wrench. Make sure only the coupling nut is turned, not the cable connector. Counter wrench Page 28 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning 4.2.8. PSR Alarms Connection For the location of the ALARM RELAY connector, refer to chapter 4.2.3. The corresponding cable is part of the delivery:
figure 4-3 PSR alarms cable Note: The correct connection of this cable to the dedicated annunciator at the site, which must be part of the buildings fire alarm system, is the sole responsibility of the installer. Note: The connected dedicated annunciator must be capable of detecting a single ground or open. End-of-line resistors with a value of 2.2 k Ohm are installed between the normally open and common relay contacts to support the supervision. Note: The source connected to the ALARM RELAY connector (i.e. the dedicated annunciator) must be power limited as defined by UL 2524 Chapter 44.1.2 Note: The length of the connected cable must not exceed 30 meters (98.5 ft). Technical parameters for the delivered alarms cable Coupling:
Environmental characteristics: Ambient temperature:
Material:
Thread locking IP rating:
-40C ~ +90C IP67 Technical parameters for the alarm relays Rated current/voltage:
Contact resistance:
Insulation resistance:
1A / 24VDC
<=100m Ohm max. 1000M Ohm min. (500VDC) MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 29 4. Commissioning PSR Alarm Function Description PSU Fail Alarm This alarm is raised if there is a problem with internal power supply. If the output level is higher than the DL shutdown level, the amplifier is turned off and the DL shutdown alarm is activated. The shutdown cycle is 60 seconds. DL Shutdown Alarm UL Shutdown Alarm If the output level is higher than the UL shutdown level, the amplifier is turned off and the UL shutdown alarm is activated. The shutdown cycle is 60 seconds. Manual Amp Off This alarm is raised when the user turns off the Amplifier manually. Service Antenna VSWR Alarm This alarm occurs when the current VSWR ratio is higher than the set VSWR ratio. If it is lower than the set VSWR ratio, it is cleared immediately. Donor Antenna Malfunction Alarm DL HPA Fail Alarm UL HPA Fail Alarm This alarm is caused by one of the following reasons:
This alarm occurs when the current VSWR ratio is higher than the set VSWR ratio. If it is lower than the set VSWR ratio, it is cleared immediately. This alarm is raised when the DL input power level is below -90 dBm. This alarm is raised if the DL high power amplifier HPA is on and an overcurrent or low current state is detected. Under this condition, the HPA is automatically switched off. This alarm is raised if the UL high power amplifier HPA is on and an overcurrent or low current state is detected. Under this condition, the HPA is automatically switched off. PLL Lock Detector Alarm This alarm occurs when the PLL is unlocked. In addition, all high-
power amplifiers will be switched off. Isolation Alarm This alarm occurs when the isolation between donor and coverage antenna is not at least 20 dB above the repeater gain. Temperature Alarm This alarm occurs when the repeater is used outside of its specified temperature range. (>80 Celsius device temperature) Donor Antenna Disconnection Alarm Without UL traffic the donor antenna is checked every 3 minutes to see if it is connected. The alarm is based on the donor antenna calibration described in chapter 5.7.5 VSWR Check and Donor Calibration. Note: For possible countermeasures, please refer to chapter 6 Status LEDs, PSR Alarms, and Troubleshooting. Page 30 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning Pinning of M12 Circular Plug-12P (male) Relay Pin 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 Name Color brown blue white green pink yellow black gray red violet orange NC NO CC NC NO CC NC NO CC NC NO CC light green PSR alarm monitoring Relay picture Donor Antenna Connection 11 Detail view A Dry Contacts PSR alarm Information Pins 10,11,12 Pins 4,5,6 Pins 7,8,9 Pins 1,2,3 Relay 1 Relay 2 Relay 3 Relay 4 NC+CC NO+CC NC+CC NC+CC NC+CC NO+CC NC+CC NC+CC NO+CC NC+CC NC+CC NC+CC Dry Contacts PSR Alarm Information Donor Antenna Disconnection DL Shutdown Alarm UL Shutdown Alarm PLL Lock Detector Alarm Isolation Alarm NC+CC NO+CC NC+CC NC+CC Oscillation Alarm NC+CC NO+CC NC+CC NC+CC Temperature Alarm NC+CC NO+CC NC+CC NC+CC Service Antenna VSWR Alarm Donor Antenna Malfunction DL HPA Fail Alarm NC+CC NC+CC NC+CC NO+CC NC+CC NC+CC NO+CC NC+CC NC+CC NO+CC NC+CC NC+CC NC+CC NC+CC NO+CC NC+CC UL HPA Fail Alarm NC+CC NC+CC NC+CC NO+CC Manual Amp Off NC+CC NC+CC NC+CC NO+CC System Failure
(failure of critical system components) Antenna Failure
(malfunction of the donor/ser-
vice antennas) PA Failure
(failure of active RF-emitting devices Normal (NC+CC), Alarm (NO+CC) NC 1,4,7,10 / NO 2,5,8,11 / CC 3,6,9,12 Alarm Status. Relay Contact:
4.2.9. LAN Connection For local access to the PSR user interface via LAN (supplementary use; not mandatory for operation), connect an RJ485 network cable to the NMS/GUI connector (location see figure 4-1). Make sure that your local PC meets the requirements specified in chapter 5.1 LAN Settings at Local PC. This connector is power limited as defined by UL 2524 Chapter 44.1.2 and therefore there is no need to run the connected cable through conduit. Note: The length of the connected cable must not exceed 30 meters (98.5 ft). MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 31 4.2.10. Power Connection 4. Commissioning Before connecting electrical power to the PSR, the system must be grounded as described in section 4.2.4 Grounding (Earthing). To get access to the terminal blocks the front door must be opened. To open the door, the locks must be opened with the supplied keys. As illustrated in section 4.2.4, remove the plastic cap to feed the supply cable into the housing. The available 1/2 common thread can be used to connect conduit. After the system has been grounded as explained in section 4.2.4, the neutral and hot wire (AC system) or the negative and positive wire (DC system) must be connected to the internal power supply unit as described in table 4-2 Power supply connection (AC) and table 4-3 Power supply connection (DC). To connect the wires remove the protective plastic cover, loose the desired screw and connect the spade terminals as illustrated in figure 4-4 AC wires, installation example or figure 4-5 DC wires, installed, respectively. Polarity of cable end Neutral Hot Green/Yellow Cable end:
spade terminal spade terminal ring terminal Connect to terminal:
N L Ground bolt table 4-3 Power supply connection (AC) PSU GND cable
(pre-installed by supplier 27 DC cable from PSU (pre-installed by supplier Network and alarm cables (pre-installed by supplier Example of local power cable (to be provided by installer) figure 4-4 AC wires, installation example Notice: For the installation, observe that a minimum air gap of inch (6.4 mm) must be maintained between the local power cable wires and the network/alarm cables that are pre-installed by the supplier. A good practice is to cut the local cable to a suitable size so that it will be led directly (without being wound up) from the opening in the cabinet to the power connectors (N, L). In that way the air gap can be kept as shown in the example above. Page 32 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 4. Commissioning Polarity of cable end Positive Negative Green/Yellow Cable end:
spade terminal spade terminal ring terminal Connect to terminal:
DCIN+
DCIN-
Ground bolt table 4-3 Power supply connection (DC) PSU GND cable (pre-
installed by supplier Network and alarm cables (pre-installed by supplier Example of DC wires of local power cable (to be provided by installer) figure 4-5 DC wires, installed Notice: For the installation, observe that a minimum air gap of inch (6.4 mm) must be maintained between the local power cable wires and the network/alarm cables that are pre-installed by the supplier. A good practice is to cut the local cable to a suitable size so that it will be led directly (without being wound up) from the opening in the cabinet to the power connectors (DCIN+/DCIN-). In that way, the air gap can be kept as shown in the example above. Note: Observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. Note: Do not install or deinstall the power wires at the POWER terminal blocks while power is on. Turn off mains power * before connecting the power wires at the PSR, then, engage mains again.
* Mains power must be interruptible with an external delayed-actions mains breaker. For the mains breaker use current state-of-the-art material. The following table can be used as reference but please make sure that your local requirements / local regulations of the AHJ are kept. Supply source Inrush current 115 VAC 20 A Nominal current (max.) 1.5 A 230 VAC 48 VDC 40 A 0.75 A 45 A 3.5 A Examples mains breakers for suitable 3 A Class C 2 A Class K 7 A Class C 4 A Class K 8 A Class C 5 A Class K MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 33 5. Setting up the Web GUI 5. Setting up the Web GUI NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER INVOLVED PARTIES This product incorporates field-programmable software. In order for the product to comply with the requirements in the Standard for In-building 2-Way Emergency Radio Communication Enhancement Systems, UL 2524 certain programming features or options must be limited to specific values or not used at all as indicated below. Program feature or option Permitted in UL 2524 (Y/N) Possible settings Settings permitted in UL 2524 Deactivate Alarms Delay Alarms N Y 1, 5, 10, 60, 600, 1380 minutes 1 minute for all alarms 5, 10, 60, 600, 1380 minutes only for donor antenna malfunction alarm 5.1. LAN Settings at Local PC In order to have access to the Web GUI, the following network adapter settings need to be set at the local PC. Setting a static IP address in the same address range (see below 192.168.1.5) is required:
Access the LAN settings of your local PC and click Properties:
Select Internet Protocol Version 4
(TCP/IPv4) and click Properties:
Enter the IP address. Click OK. Page 34 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.2. Network Management Requirements The Web GUI uses Ethernet TCP/IP communication, and as protocol SNMPv2 MIB is used. Default Ethernet telecommunication specification:
URL Address: http://192.168.1.150 Default Username: admin Default Password: admin Browser: Chrome Internet Browser 5.3. EULA Acceptance Page When a user connects first time or after a factory reset, the EULA Acceptance page appears. Tag to Accept the EULA and click Continue. If you do not accept the EULA, login to the repeater is not possible. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 35 5.4. Login Page 5. Setting up the Web GUI Enter Username and password exactly:
Default Username:
admin admin Default Password:
If you enter Username and Password incorrectly, the following message is shown:
After three false trials input of username and password will be locked for 30 seconds. 5.5. Main Page In the upper header of the main page you can select between the two main menus System Settings (see chapter 5.6) and System Operation (see chapter 5.7) by clicking the corresponding tab to get access to their individual submenus by the corresponding links in the left frame. The following buttons are also available in the upper header:
Reboot system: The entire system reboots (about 10 seconds are required.) Logout: User logging out of system. The lower header provides the following information:
Version: the installed SW version is displayed Alarm Status: If no alarm is present, the indication is Clear; if at least one critical alarm is present, the indication is Critical. Clicking on the coloured alarm status field (Clear or Critical) opens the Active Alarm page (see chapter 5.7.1). Temperature: The system temperature is displayed. Page 36 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.6. System Settings 5.6.1. License Upgrade A license upgrade is always required in case of feature upgrades. The corresponding license key (SW feature key) has to be entered in the Update License Key field as described below. Device Information: Information on Device ID, MAC Address, Serial No, and S/W Version is displayed Update License Key (= SW Feature Key) If you want to upgrade a license, you can enter the new license key and click the Save button. For a list of available license keys, see chapter 8.4 Available Configurations and SW Feature Keys. If dual band is unlocked, single band is automatically unlocked as well. If Power level 2 W is unlocked, 0.5W is automatically unlocked. Band Authorization:
Power Level Authorization:
MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 37 5. Setting up the Web GUI 5.6.2. Software Upgrade Proceed as follows:
Note: The SW update process will take approximately 3min 45sec overall. A loss of service for about 3 min 15 sec has to be expected. Get an update file from CommScope Technical Support (see chapter 1.6.1) and store the file at a suitable location where you can access it. Click the Choose File button and select the software update file from where you stored it previously. Open the file and click the Update button to start the software update. NOTE:
Do not turn off the device during software updates since this might result in system corruption. During the update process the following information is displayed:
When the update is complete, you automatically move to the Login page. Page 38 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.6.3. Restore Factory Defaults Note: Be aware that only RF Settings (i.e. OMC IP Address, Band / Channel settings, Broad and Narrow Band Mute Threshold Level, Return Loss Threshold, User ATTN) will be saved in the backup file. All "General RF Setting" buttons e.g. ALC, HPA stay at their current positions. Description of buttons:
Save Backup: The system's RF Setting information is downloaded to your PC as backup.dat file. Restore File / Choose File: Click to select the backup file to be opened. Restore: The RF Setting information is restored from the backup file. Factory Default: The RF Setting information is restored to Factory Default status. Both the Alarm History log and Event History log files are deleted, and the system is rebooted. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 39 5. Setting up the Web GUI 5.6.4. My Account Management This page serves to enter your account data. My Information:
You can update Username, Company, Contact Number, Email Address, and Role information. Confirm your settings with the Update button. Change Password:
To change your password, enter the new one in both fields and confirm with the Change Password button. The following password requirements which are also listed on the page must be observed:
It must be between 8 and 16 characters long. It must contain only Latin-based alphanumeric characters. It must contain at least one capital letter, one small letter, and one number. In case you forget or inadvertently change this information, a reset to factory defaults is required. To do so, refer to chapter 6. Page 40 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.6.5. IP Settings The factory default IP settings are as follows:
IP Address: 192.168.1.150 Subnet Mask: 255.255.255.0 Broadcast: 192.168.1.255 Gateway: 192.168.1.1 Primary DNS: 0.0.0.0 Secondary DNS: 0.0.0.0 Note: If you change these settings as described below make sure to safely store the new IP settings: You will always need them to reach the PSR. To change the settings (e.g. to integrate the PSR into an existing network), type in the corresponding data and click the Save button to confirm. The following message appears:
Click the OK button to confirm the changed IP Settings and the system will reboot. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 41 5. Setting up the Web GUI 5.6.6. OMC Connection The following parameters can be entered:
OMC Server IP Address:
A total of 5 OMC Server IP Addresses can be entered. Factory default IP Address: 0.0.0.0 Alarm Notification:
Heartbeat ON / OFF function Heartbeat Interval time set function: 1 to 1440 min can be set. Click the Save button to confirm the changed OMC Connection settings and the PSR will reboot for the SNMP daemon to restart. Page 42 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.6.7. Alarm Settings This page serves to mask / unmask alarms:
Click the corresponding symbol in the Active column to set the respective alarm ON
(blue) or OFF (dark grey). This setting has the following effect:
Active ON: When an alarm is triggered, the corresponding alarm LED and alarm relay are selected and a MIB Notification Alarm is generated. Active OFF: When an alarm is triggered, neither the corresponding alarm LED nor the alarm relay are selected, and the MIB Notification Alarm is also masked. Delay: All alarms related to the installation can be delayed between 1 minute and 23 hours. The status "OFF" means that the time between an alarm condition and the corresponding alarm depends on the measurement cycle, e.g. 3 minutes for
"Donor Antenna Disconnection Alarm". The alarm settings cannot exceed the programmable limits indicated in the table at the beginning of chapter 5. Click the Save button to confirm the settings. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 43 5. Setting up the Web GUI 5.6.8. General RF Setting Band Selection: If the Feature Key ID is dual-band (as in the example below) both the 700 MHz Band and 800 MHz Band can be selected. If the Feature Key ID is single-
band, you can select either the 700 MHz Band or the 800 MHz Band. Only the items corresponding to the Feature Key ID, including RF Settings, are Active. Analog Band Selection [Class B]: (only available for analog Class B variant): The 800 MHz passband can be set to 851 - 869 MHz, 851 - 861 MHz and 851 - 854 MHz. DOWNLINK / UPLINK:
Band: The band to which the settings in this line correspond is displayed. Gain. This parameter shows the current PSR gain (default setting is 90 dB): This value can be reduced with the User ATTN setting (see below). ALC: Use this button to switch ALC ON /OFF, however deactivating ALC can cause the system to exceed allowed FCC levels. HPA: Use this button to switch High Power Amplifier ON /OFF. If switched to OFF, the entire band is deactivated. User ATTN: The PSR gain can be reduced by 0 (= default) to 30 dB in steps of 0.5 dB to a minimum value of 60 dB. For additional adjustments per channel see chapters 5.6.10 and 5.6.11. RL Threshold: The return loss threshold used for the VSWR Check (see chapter 5.7.5) can be set in the range from 0 to 30 dB. Broad Mute Level: Set the UL mute threshold level [broadband] (-105 to -60 dBm).*
Narrow Mute Level: Set the UL mute threshold level [narrowband] (-110 to -60 dBm).*
If the UL input power falls below the set threshold, UL squelch/mute is activated. Default is -105 dBm
for broadband channels and -110 dBm for narrowband channels (Class A only). For Class B type units, the whole band will be muted. With UL squelch/mute active, the UL gain is reduced by 30 dB. With the Mute ON/OFF button, muting can be generally deactivated/activated. The button indicates the currently chosen muting status. Once you have finished RF setting, press the Save button to change the settings. Page 44 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.6.9. Channelized ALC (Class A Only) If the input power for one active channel results in an output power that exceeds the maximum output power per channel, the related channel gain is automatically and individually reduced. The maximum possible output power per channel depends on the enabled power class (0.5 W or 2 W) and the number of active channels and can be calculated by dividing the maximum possible output power per band by the number of active channels. Examples are shown in the following table. Maximum UL output power per channel Maximum DL output power per channel Power class Active Channels 1 4 8 16 32 0.5 W 27 dBm 21 dBm 18 dBm 15 dBm 12 dBm 2 W 27 dBm 21 dBm 18 dBm 15 dBm 12 dBm 0.5 W 27 dBm 21 dBm 18 dBm 15 dBm 12 dBm 2 W 33 dBm 27 dBm 24 dBm 21 dBm 18 dBm The user gain setting is immediately restored when the channel output power is equal to or below the maximum possible value. 5.6.10. 700 MHz Channels (Class A Only) 700 MHz Band Digital Filter Channels Configuration:
Broadband (LTE): CH1, CH2 Filter BW: OFF, 5, 10, 17 MHz*
Narrowband: CH3 ~ CH34 Filter BW: OFF, 12.5, 25, 50, 75, 100, 150, 250 kHz*
* Filters above 75 kHz are only available in Class B mode. For a detailed explanation on using this mode, refer to chapter 5.6.12 and strictly observe the important COMPLIANCE Notice in this chapter. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 45 5. Setting up the Web GUI For filter details also observe table 8-1 Digital filters (narrowband) for Class A repeaters or table 8-2 Digital filters (broadband) for Class A repeaters, respectively. Center Freq. Setting: Set up the Center Freq. per each channel. Center Freq. Range: 758.000000 ~ 775.000000 (MHz) Ref: DL Freq. Digital Gain Setting: DL/UL gain control per each channel *
Digital Gain Control Range: +/- 5 dB in steps of 0.5 dB Start Freq.: Calcuate Center Freq - (Bandwidth/2) (display Only) Stop Freq.: Calculate Center Freq + (Bandwidth/2) (display Only)
* An additional gain offset between -5 and +5 dB can be set for each defined channel to compensate components with frequency-dependent insertion loss, e.g. external filters or splitters. The end-to-end gain (total system gain) including external components (not antennas) must not exceed a gain of 90 dB. If you require more detailed information with an example of an end-to-end gain equation, ask our Technical Support (for contact data, please refer to chapter 1.6.1). Once you have finished Channel settings, press the Save button to change the settings. 5.6.11. 800 MHz Channels (Class A Only) 800 MHz Band Digital Filter Channels Configuration Broadband (LTE): CH1, CH2 Filter BW : OFF, 5, 10, 17 MHz*
Narrowband: CH3 ~ CH34 Filter BW : OFF, 12.5, 25, 50, 75, 100, 150, 250 kHz
* Filters above 75 kHz are only available in Class B mode. For a detailed explanation on using this mode, refer to chapter 5.6.12 and strictly observe the important COMPLIANCE Notice in this chapter. For filter details also observe table 8-1 Digital filters (narrowband) for Class A repeaters. Page 46 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI Center Freq. Setting: Set up the Center Freq. per each Channel. Center Freq. Range: 851.000000 ~ 869.000000 (MHz) Ref: DL Freq. Digital Gain Setting: DL/UL gain control per each channel *
Digital Gain Control Range: +/- 5 dB in steps of 0.5 dB Start Freq.: Calcuate Center Freq. - (Bandwidth/2) (Display Only) Stop Freq.: Calcuate Center Freq. + (Bandwidth/2) (Display Only)
* An additional gain offset between -5 and +5 dB can be set for each defined channel to compensate components with frequency-dependent insertion loss, e.g. external filters or splitters. The end-to-end gain (total system gain) including external components (not antennas) must not exceed a gain of 90 dB. If you require more detailed information with an example of an end-to-end gain equation, ask our Technical Support (for contact data, please refer to chapter 1.6.1). Once you have finished Channel settings, press the Save button to change the settings. 5.6.12. Digital Channels (Class B mode) Special circumstances, such as high carrier density combined with low group delay or a combined use of FirstNets Band 14 with narrow PS carriers, require a mix of the flexible filters of a class A repeater and the low group delay of a class B repeater. To cover these requirements as well, the digital class A repeater has been designed and granted by FCC to be easily configured as a class A or class B repeater. COMPLIANCE Notice:
When using Class B mode, you MUST register the PSR as a Class B signal booster (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-boosters/registration. To use the Class B mode, simply choose a filter above 75 kHz (marked in red), observe the WARNING message, and accept it by pressing Ok. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 47 5.6.13. Site Location Use this page to enter the Site Location information:
5. Setting up the Web GUI 5.6.14. Time and Date Use this page to enter the Time and Date information:
CompanyName:
You can enter up to 30 characters. Address:
You can enter up to 30 characters. City:
You can enter up to 30 characters. State/Province/Territory:
You can enter up to 10 characters. Zip/Postal Code:
You can enter up to 10 characters. Contact:
You can enter up to 20 characters. Click the Save button to save the Site Location information on the device. Time Zone: When Time Zone is selected, the daylight-saving time is applied. Date and Time: Press the Refresh button to get the current repeater date and time; the user can change the Date and Time manually. Save Button: Save the changed Date/Time and Time Zone on the Device. Save with PC Time: Save the date/time of the connected PC to the device (you should have set the Time Zone before). Note Date/Time is reset if PSR power is off for more than 2 days. Page 48 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.6.15. Summary Use this page to display a summary of all device, RF, and Alarm settings. The user can download the summary to PC by using the "Create Report" button located at the end of the summary. Summary File: The summary file is named as occurred date and time and the file is saved in the chosen folder, e.g. summary_190729AA0005_20201117_1509.html. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 49 5. Setting up the Web GUI 5.7. System Operation 5.7.1. Active Alarm 1) You can view the currently active alarms. 2) Alarm test is a function that performs an alarm simulation: This includes sending SNMP traps as well as activating the related LED and relay. Alarm Count: Auto / Manual Alarm count displayed. Alarm History Storage:
When Alarm Test is ON, the alarm is stored as a manually triggered alarm in the alarm history. Test Duration:
When Alarm Test is switched ON, a 10-minute counter starts. After the counter has reached zero, the alarm test is switched OFF automatically. The individual remaining time is displayed in the Test Duration column. Temperature Alarm test is not available. Page 50 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.7.2. Alarm History If an Alarm occurs in the Repeater, it will be stored in the Alarm History. If the user switches On the Alarm Test to test the alarm, it is stored as a manually trigged alarm in the alarm history. The alarm history can be cleared by using the Clear Alarm History button. Alarm History Log File: The Alarm Event file is named as occurred date and the file is saved in the chosen folder, e.g. 20190226.log. Alarm History Log File Content: Saved as a Csv file, separated by commas, e.g. 2019021613:00:22, Critical,Auto,PSU Fail Alarm Download the Alarm History Log File to PC: The user can download the Alarm History log file to PC, and then perform the download function by compressing all of the Alarm Log files at one time. Alarm History Search Function: You can search by Event Date, Alarm Item, Alarm Trigger, and Alarm Level, e.g. when Manual AMP is entered in the Search window, only the detected alarm is displayed. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 51 5.7.3. Event History 5. Setting up the Web GUI This page shows the user log in information and history of changes to the RF settings. The event history can be cleared by using the Clear Event History button. Event History Log File: Event file is named as occurred date, and the file is saved on System Event History Folder, e.g. 20190226.log. Event History Log File Content: Saved as a Csv file, separated by commas, e.g. 2019021613:00:22,David,logged in Download the Event History Log File to PC: The user can download the Event History log file to PC, and then perform the download function by compressing all of the Event Log files at one time. Event History Search Function: You can search by Event Date, Event, and User Name. Page 52 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 5. Setting up the Web GUI 5.7.4. Antenna Isolation Check The progress is displayed:
Click the TEST button to start the Antenna Isolation Check. When the Isolation Check is completed, the Isolation value and Maximum Gain are displayed (maximum gain is calculated with Isolation minus 20 dB):
Maximum Gain: 90 (Green color), Maximum Gain : 89~ 60 dB (Orange color), Maximum Gain: < 60dB (Red color) Isolation Fail 5.7.5. VSWR Check and Donor Calibration Click the Refresh button to display the current VSWR Ratio. Click the Donor Calibration button to start the calibration. If the Return loss value is less than the Threshold value, the VSWR Fail Alarm is generated. The shading will change from green to red in case of an alarm. The threshold (RL Threshold) under which an alarm will be generated can be set in the General RF Setting (see chapter 5.6.8). MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 53 5. Setting up the Web GUI With the donor calibration, the reference level for the Donor Antenna Disconnection
(DAD) Alarm can be set. Follow the procedure described below to successfully activate the donor antenna connection supervision. I. Connect the donor antenna cable* without antenna to BDA II. Press the Donor Calibration button on page System Operation--> VSWR Check III. The DAD alarm will appear within 3 minutes IV. The DAD alarm shall disappear within 3 minutes after donor antenna** is connected
* A maximum donor antenna cable loss of 8 dB at 900 MHz (ca. 328 ft /100 m with CNT-600) is supported. Please use a donor cable with a larger diameter or install a UL2524 certified 3rd party device capable of supervising the antenna connection in case longer cable runs are necessary.
** An antenna with at least 7 dB RL must be used 5.7.6. 700MHz Band Overview This page displays the current 700 MHz band setting and the Input/Output Power Level. If you want to check the status again, you can click the 700 MHz Band menu button or F5 refresh key to perform the status check. Automatic gain reduction is indicated by orange color. 5.7.7. 800MHz Band Overview This page shows the current 800 MHz band setting and the Input/Output Power Level. If you want to check the status again, you can click the 800 MHz Band menu button or F5 Key to perform the status check. Page 54 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 6. Status LEDs, PSR Alarms, and Troubleshooting 6. Status LEDs, PSR Alarms, and Troubleshooting For local supervision, three multi-color LEDs (Power, OSC, and Alarm) are part of the front panel to display unit status information. During booting and SW update, all three LEDs blink green, indicating that initialization and isolation measurement are in process. When the boot process is finished, and the repeater works properly, all three LEDs are green to indicate normal operation. The table below shows possible PSR alarm conditions indicated by the LEDs as well as possible countermeasures. Status LED Power LED Indication Red PSR alarm condition DC/DC failure Red Blinking Isolation Alarm Trouble & Status condition Possible countermeasure Try to reboot the unit; if this is of no effect, the unit has to be sent back to the supplier. Insufficient isolation between antennas Increase isolation between donor and coverage antenna above gain + 20dB. OSC LED Green Blinking VSWR Alarm UL/DL VSWR Alarm, Antenna failure OSC &
Alarm LED Red Blinking PLL Lock Detector Alarm PLL is unlocked antennas Check for proper connection and between for antenna ports. Check obstacles close to antennas. Check for short-circuit of antenna cables. Reset unit via Reset button in Web GUI*. If the alarm is still present, contact your supplier. Red HPA Fail Alarm UL/DL High Power Amplifier failure Reset unit via Reset button in Web GUI*. If the alarm is still present, contact your supplier. Alarm LED Red Blinking Shutdown Alarm Green Blinking Manual Amp Off UL/DL Shutdown or Temperature Alarm Amplifier turned off by factory setting or by user. Make sure that RF input power and ambient temperature are within specified limits and try a manual restart. Turn amplifier on via Web GUI.
* Do not use the HW Reset button in the unit for this purpose, as it will set back all data to factory defaults. Only use the HW button (as described in chapter 7.2) if the IP address or password was inadvertently changed or forgotten. table 6-1 Status LED indication and troubleshooting MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 55 7. Maintenance 7. Maintenance 7.1. General Read and observe chapter 1.2 Health and Safety. Caution: The unit reaches high temperature in operation. Risk of burns by hot surface. Do not touch the unit before it has sufficiently cooled down. Note: The repeater does not require preventative maintenance measures. Note: We recommend checking the cleanliness of the unit and in particular of the heat sink at appropriate intervals depending on the degree of dust and dirt at the installation site. If necessary, any dusty or dirty areas / parts should be cleaned from debris at regular intervals, which also depend on the degree of debris at the installation site. Unless otherwise agreed to in writing by CommScope, CommScopes general limited product warranty (http://www.commscope.com/Resources/Warranties/) shall be the warranty governing the unit, including the installation, maintenance, usage and operation of the units. Note:
Ensure the repeater has been disconnected from mains power during maintenance. Note: When sending back the unit, use appropriate packaging (see also section 8.3.2 Mechanical Specifications for details). Use of the original packaging for shipping the unit is strongly recommended. Note:
Note:
Defective parts should only be replaced by original parts from the supplier. All service work performed inside the housing is performed at the users own risk. Label any unlabeled cables before disconnecting them to ensure correct reconnection. For some maintenance procedures, appropriate tools may be required to ensure correct handling. All of these tools can be ordered from the supplier. Note:
All repeater screws have a right-hand thread and are tightened by turning the screws clockwise and loosened by turning them counter-clockwise with an appropriate tool. The following spare parts are also listed with their corresponding IDs in chapter 8.5. Description Alarm cable 2m AWG 26 Key for Lock For installation / connection, refer to chapter 4.2.8
Note:
Ensure that all relevant compliance rules listed in chapter 1.4 are observed when the system is powered up again after maintenance. Page 56 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 7. Maintenance 7.2. Reset to Factory Defaults If the IP address or password was inadvertently changed or forgotten so that access to the Web GUI is not possible, a Reset button inside the unit is provided. Note:
Be aware that this button will set back ALL data to factory defaults. Notice: As using the Reset button requires the unit to be in operation while open, only suitably qualified personnel are allowed carry out the procedure described in the following and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. Note: Read and observe chapter 7.1 before starting with the procedure. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. Use the key provided with the unit to unlock both locks at the left side of the cabinet and unlatch them. Then, you can open the cabinet door. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Make sure not to touch anything but the Reset button. The Reset button is located on the Control Board (located in the top right corner of the repeater):
figure 7-1 Location of Control Board figure 7-2 Reset button on Control Board Press the button for 5 seconds and a restart of the Web GUI will be initiated, setting back the settings to the factory defaults:
IP Address: 192.168.1.150 Heartbeat ON OMC Connection IP Address: 0.0.0.0 30min Heartbeat Interval:
Thus, you can login to the Web GUI with the default password again. Note: Do not forget to close the cabinet, latch the two locks and lock them with the key. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 57 7. Maintenance 7.3. Cleaning the Heat Sink Note: Read and observe chapter section 7.1 before starting with the procedure. Then, proceed as follows:
Checking the cleanliness of the heat sink is recommended at appropriate intervals depending on the degree of dust and dirt at the installation site. If necessary, any dusty or dirty areas / parts should be cleaned as explained in the following:
Read and observe chapter 1.2 Health and Safety as well as the instructions in section 7.1 General before starting with the cleaning. Disconnect the mains cable from the POWER connector (see figure 4-1). Caution: The unit reaches high temperature in operation. Risk of burns by hot surface. Do not touch the unit before it has sufficiently cooled down. Use a soft brush to remove dust and dirt from the fins of the heat sink. After cleaning reconnect power cable. Page 58 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 8. Appendix 8. Appendix 8.1. BBU/UPS Requirements 1) In order to obtain a system that is compliant with UL 2524, the BBU/UPS must be compliant with UL 2524 too. 2) Choose a BBU/UPS capacity that fits to the responsible AHJs (Authority Having Jurisdiction) requirements. You can use this table for reference:
BBU capacity (48 VDC) Single Band Dual Band 12 h 31 Ah 40 Ah UPS capacity (110 VAC) Single Band Dual Band 12 h 16 Ah 19 Ah 24 h 61 Ah 80 Ah 24 h 32 Ah 38 Ah 3) The BBU/UPS output voltage must be within the range of the specified input voltage range of the BDA:
BBU DC operating range UPS AC input rating AC operating range
-62 to -34 VDC 104 ~ 240 VAC 89 to 264 VAC 8.2. Illustrations figure 8-1 External configuration MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 59 8. Appendix figure 8-2 Cabinet measurements Page 60 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 8. Appendix The following cabling plan shows the example of a DC installation with a BBU; the setup of AC installations using a UPS is the same (for details on the UPS installation, refer to the corresponding installation manual of the UPS):
figure 8-3 Cabling plan (with BBU for DC installations) MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 61 700MHz Band 800MHz Band 8.3. Specifications 8.3.1. RF Performance Frequency range UL Frequency range DL Instantaneous bandwidth RF technology Duplex UL/DL output power max. per band for 2 W type UL/DL output power max. per band for 0.5 W type Frequency range UL Frequency range DL Instantaneous bandwidth RF technology Duplex UL/DL output power max. per band for 2 W type UL/DL output power max. per band for 0.5 W type 8. Appendix 788 to 805 MHz 758 to 775 MHz 17 MHz P25 + LTE (758 768 MHz) FDD 27/33 dBm / carrier @ 1 carrier 24/30 dBm / carrier @ 2 carriers 21/27 dBm / carrier @ 4 carriers 18/24 dBm / carrier @ 8 carriers 27/27 dBm / carrier @ 1 carrier 24/24 dBm / carrier @ 2 carriers 21/21 dBm / carrier @ 4 carriers 18/18 dBm / carrier @ 8 carriers 806 to 824 MHz 851 to 869 MHz 18 MHz P25 FDD 27/33 dBm / carrier @ 1 carrier 24/30 dBm / carrier @ 2 carriers 21/27 dBm / carrier @ 4 carriers 18/24 dBm / carrier @ 8 carriers 27/27 dBm / carrier @ 1 carrier 24/24 dBm / carrier @ 2 carriers 21/21 dBm / carrier @ 4 carriers 18/18 dBm / carrier @ 8 carriers All figures are typical values, unless otherwise stated. All data is subject to change without notice. Page 62 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 8. Appendix Channel Bandwidth
(kHz) 12.5 25 50 75 100 150 200 3 dB Bandwidth
(kHz) 23 46 92 138 184 276 459 Delay typ.
(s) 98.5 52 27.5 20 16 12 9 No. 1 2 3 4 5 6 7 13 26 52 78 105 155 255 Rejection Fc(kHz) Ripple
(dB) 72 dBc 71 dBc 72 dBc 78 dBc 88 dbc 74 dbc 78 dbc 0.49 0.46 0.49 0.52 0.54 0.56 0.61 Channel Distance *
(kHz) 31.25 56.25 106.25 156.25 206.25 312.5 512.5 table 8-1 Digital filters (narrowband) for Class A repeaters
* The center frequencies of two filters with the same bandwidth must have at least this distance; center frequencies are set in the channel pages of the System Settings (see chapter 5.6.10 and 5.6.11). No. 1 2 Channel Bandwidth
(MHz) 3 dB Bandwidth
(kHz) Delay typ. (s) Channel Distance *
(kHz) 5 10 4950 9470 5 5 5000
table 8-2 Digital filters (broadband) for Class A repeaters
* The center frequencies of two filters with the same bandwidth must have at least this distance; center frequencies are set in the channel pages of the System Settings (see chapter 5.6.10 and 5.6.11). Selectivity Paramenter Band 700 MHz 800 MHz Channel Bandwidth 17 MHz 3 MHz 10 MHz 18 MHz Value Delay RF_IN RF_OUT Rejection 3.5 s 40 dBc @ 2 MHz table 8-3 Selectable passbands for class B repeaters All figures are typical values, unless otherwise stated. All data is subject to change without notice. MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 63 8. Appendix 8.3.2. Mechanical Specifications Parameter Size *
Weight Connectors Mounting Type Heat Dissipation Specification 400 x 480 x 170 mm
(15.75 x 18.9 x 6.69 in) 19 kg (41.89 lb) Antenna port Monitoring port Battery Back-up port
(not for customer use) Remark W x L x H
4.3.10 (female) SMA (female) -30dB coupling YJ3102R-16-10S Dry Contacts for alarming NMS/Local GUI Wall Mounting Natural Convection M12 12Pin Female Circular Connector Panel Mount RJ-45 Ethernet (17-101754)
Spacing required: 300 mm (11.81 in) around unit All data is subject to change without notice. 8.3.3. Power Specifications Parameter Power consumption Dual Band Power consumption Single Band AC Power supply input range DC Power supply operating range Voltage Current (Single Band) Current (Dual Band) Voltage Current (Single Band) Current (Dual Band) Value Typ. 140 W, Max. 160 W. Typ. 100 W, Max. 120 W. 104 ~ 240 VAC / 60 Hz (50 Hz / 60 Hz) 1.15 0.5 A 1.38 0.6 A
-62 ~ -34 VDC 1.63 2.97 A 2.13 3.88 A All figures are typical values, unless otherwise stated. All data is subject to change without notice. Page 64 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 8. Appendix 8.3.4. Environmental and Safety Specifications Environmental Sealing class UL Type 4X / IP66 Storage (ETS 300 019 2 1, class 1.2) Temperature Vibration (sinusoidal) Vibration (random) Shock Humidity Water
- 25 to + 70 C 5 62 Hz / 0.5 mm displacement 0.2 g @ 62 200 Hz, 3 x 5 sweeps 0.02 m2/s3 10 50 Hz
+12 dB / Oct. 5 10 Hz
-12 dB / Oct. 50 100 Hz 3 x 30 min none
+ 30 C / 93 % / 96 h none Stationary use Operating temperature Humidity
-25 to +50 C *
+32C / 93% / 24 hours
* The ambient temperature intended for installation and operation is 25C (77F), but the PSR is fully functional between -25 and +50C. All data is subject to change without notice. 8.4. Available Configurations and SW Feature Keys The Feature Key IDs (listed at the end of this chapter) do not distinguish between Class A, B and DC, AC type. A detailed list of available configurations is provided below. Class A:
AC Configurations PSR 700 OR 800 MHZ 2W CLASS A AC PSR 700 AND 800 MHZ 2W CLASS A AC PSR 700 OR 800 MHZ 0.5W CLASS A AC PSR 700 AND 800 MHZ 0.5W CLASS A AC PSR 700/800 MHZ 0.5/2W LOCKED CLASS A AC DC Configurations PSR 700 OR 800 MHZ 2W CLASS A DC PSR 700 AND 800 MHZ 2W CLASS A DC PSR 700 OR 800 MHZ 0.5W CLASS A DC PSR 700 AND 800 MHZ 0.5W CLASS A DC PSR 700/800 MHZ 0.5/2W LOCKED CLASS A DC ID No. 7831758-0001 7831758-0011 7831758-0012 7831758-0013 7831758-0014 ID No. 7831758-0002 7831758-0021 7831758-0022 7831758-0023 7831758-0024 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 65 8. Appendix Class B:
AC Configurations PSR 700 OR 800 MHZ 2W CLASS B AC PSR 700 AND 800 MHZ 2W CLASS B AC PSR 700 OR 800 MHZ 0.5 CLASS B AC PSR 700 AND 800 MHZ 0.5W CLASS B AC PSR 700/800 MHZ 0.5/2W LOCKED CLASS B DC DC Configurations PSR 700 OR 800 MHZ 2W CLASS B DC PSR 700 and 800 MHz 2W Class B DC PSR 700 or 800 MHz 0.5W Class B DC PSR 700 AND 800 MHZ 0.5W CLASS B DC PSR 700/800 MHZ 0.5/2W LOCKED CLASS B DC ID No. 7831851-0001 7831851-0011 7831851-0012 7831851-0013 7831851-0014 ID No. 7831851-0002 7831851-0021 7831851-0022 7831851-0023 7831851-0024 Feature Keys:
Feature Key ID 7835720 7835721 7835687 7835689 785359 Feature Description 2W, Dual Band 2W, Single Band 0.5W, Dual Band 0.5W, Single Band Lock Device Note: In order to get new feature keys, contact CommScope Technical Support (see chapter 1.6.1). 8.5. Spare Parts The following spare parts are available for the PSR 700/800 MHz:
Material ID 7841377 7841374 Description Alarm cable 2m AWG 26 Key for Lock The manufacturer reserves the right to replace the parts listed above by equivalent substitutes. Page 66 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz 9. List of Changes 9. List of Changes Version Changes MF0123A1E MF0123A1F
- Additional filters and Class B mode information added in chapters 5.6.10 and 5.6.11
- Chapter 5.6.12 on Class B mode added
- Additional filters added in table 8-1
- Restriction for Canada removed in chapter 8.3.1
(editorial) Release Date 22-March-2021 15-April-2021 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz Page 67 10. Index 10. Index A About CommScope .............................................. 12 B Block diagrams ..................................................... 15 C Cabinet Measurements ........................................ 60 Cabling Plan ......................................................... 61 Commissioning, general ....................................... 17 Compliance............................................................. 8 Connections Antenna ........................................................... 24 Connectors ...................................................... 23 LAN .................................................................. 31 Power .............................................................. 32 Contacting CommScope ....................................... 13 D Declaration of Conformity (DoC) ........................... 12 I Illustrations, External Configuration ...................... 59 Installation, Electrical ............................................ 22 Installation, Mechanical ........................................ 17 M Maintenance ......................................................... 56 Mechanical installation, wall mounting.................. 19 P Property Damage Warnings ................................... 7 PSR alarm relay ................................................... 29 PSR Alarms .......................................................... 55 S Specifications Environmental and Safety ................................ 65 Mechanical ...................................................... 64 Power .............................................................. 65 Status LEDs ......................................................... 55 F Functional description ........................................... 15 T Troubleshooting .................................................... 55 G Grounding (Earthing) ............................................ 23 U UL Squelch ........................................................... 44 H Health and Safety ................................................... 7 Page 68 MF0123A1F_FCC_uc Manual for PSR 700/800 MHz
1 2 3 | External Photos | External Photos | 1.32 MiB | April 28 2021 |
External Photos PSR 700/800 Class A (Digital) 7831758-xxxx
1 2 3 | Label Information | ID Label/Location Info | 912.56 KiB | April 28 2021 |
COMMSCSPE"
PSR 700 or 800 MHz 2W Class A AC ID No. : 7831758-0001 ISN : YYMMDDBA0001 Rev. : 00 arene MAC : XX.XX.XX.XX.XX.XX input : 100-240 V~, 2.0-0.6 A S0/60HZ FOC ID : XSS-PSR7EA NC : 2237E-PSRTBA Model: PSR TBA NEMA 4x For ROHS inquires Commscope inc Corke Abbey, Bray Co. Dubin, Feland Attn; Legal Department Made in Keres
@x LISTED ITE 341277 C 65.0 COMMSCSGPE"
PSR 700 or 800 MHz 2W Class A DC ID No. : 7831758-0002 ISN : YYMMDDBA0001 Rev. : 00 JUNE 2018 MAC : XX.XX.XX.XX.XX.XX Ingut:~48 Vdc. 4.08 FCC ID :XSS-PSRTEA IC :2257E-PSR7BA Model: PSRTIB A NEMA SX For ROHS ingur Commscope inc Corke Abbey, Bray Co. Dubin, retand At; Legal Department Mage in Korea. x LISTED LE 341277 C 65.0 COMMSCOPE"
PSR 700 or 800 MHz 2W Class AAC ID No. : 7831758-0001 IN a rai _SN: 190805AA0001 T Rey, : : QQ AUGUST 2019 |
MAC : FB.36.9B.E8. 19.F3
. Input : 100-240 V~, 2.0-0.6 A, S0/60Hz FCC ID : XS5-PSR78A IC : 2237E-PSR78A Model : PSR 7/8 A NEMA 4X For ROHS inquiries inc Corke Abbey, Bray Commscope Co. Dublin, Ireland Attn; Legal Department Made in Korea
/ARNING. This is NOT a CONSUMER device. tis designed for installation by FCC (or ISED in Canada) licensees and bualiied installers. You MUST have an FCC LICENSE or the express
(eee of an FCC licensee to operate this device (or ISED license or nsee consent in Canada). In the USA, unauthorized use may result in significant feiture penalties, including penalties in excess of $100,000 for each continuing violation. AVERTISSEMENT: Ce produit N'EST PAS un appareil de CONSOMMATION.
| est concu pour tre install par un installateur approuve par un titulaire de licence diSDE. Pour utiliser cet appareil, vous DEVEZ dtenir une LICENCE d'ISDE bu avoir obtenu le consentement expres d'un titulaire de licence autoris par ISDE. TENDED USE: EU AND EFTA COUNTRIES
'0 be sold exclusively to mobile operators or authorized installers, 10 harmonised frequency bands, operation needs license.
"Andrew Wireless Systems GmbH Industriering 10; 86675 Buchdort / Germany
-cycling information can be obtained from the WEEE recycling selection at www.CommScope.com For Patents See www.CS-pat.com ID: 7677757-04 NOT a CONSUMER device, It is designed for by FCC LICENSEES and QUALIFIED INSTALLERS, You 3 NSE or express consent of an FCC Licensee to a booster can be configured as a Class A or Class red as Class B signal Booster (as defined In CER 90.219), you MUST register this signal booster online at
.govisignal-boosters/registration, Unauthorized use may result in at forfeiture penalties, including penalties in excess of $100,000 for each continuing viola ID No. : 7&31758-0001 @
HNN USTED E E341277 00 MAY 2020 C MAC : F8.36.9B.12.97.AB
1 2 3 | LTC Request | Cover Letter(s) | 325.19 KiB | April 28 2021 |
Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Date: 01.0ct.2019 Product Certification K6nigswinkel 10 D 32825 Blomberg FCC ID: XS5-PSR78A To Whom it may concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby requests long-term confidential treatment of information accompanying this application as outlined below:
kX] Schematics Parts List Block Diagram &] Tune-Up Info Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentilality) withheld from the public disclosure for an initial period of 180 days LC until: LJ not applicable CJ External Photos [_] Test Setup Photos XX] Internal Photos XX] Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. Thank you for your attention in this matter. Applicants Company Andrew Wireless Systems GmbH address ; Industriering 10 86675 Buchdorf
. Andrew Signature 1 ee FutteWireless Systems GmbH Job Title and Dept. : Specialist Reliability Compliance ee ae Ersteller: D. Brandhorst Revision: 00 Erstelldatum: 02.01.2012 Datum: 00.00.0000 Seite 1 von 1
1 2 3 | Power of Attorney Letter | Cover Letter(s) | 167.70 KiB | April 28 2021 |
COMMSCOPE PHOENIX TESTLAB GmbH Product Certification Department K6nigswinkel 10 32825 Blomberg Germany To Whom It May Concern:
Please be advised that |, Wolfgang Oelrich from Andrew Wireless Systems, a COMMSCOPE Company authorizes the following person from Andrew Wireless Systems (AWS):
Mr. Frank Futter To act on my behalf to handle and sign applications of Type Approval for FCC and ISED for AWS products. This Authorization is limited until it is formally withdrawn. It does not cover the authorization at FCC which is still drawn on my name. Contact Person Wolfgang Oelrich Position in the Company Manager Quality Date of Signatory 09.April 2019
/ tll Signator
(Signature of the applicant)
1 2 3 | Label Attestation | Attestation Statements | 2.33 MiB | April 28 2021 |
COMMSCGSPE one amen 0 lndustnering 10 To whom it may concern According to KDB 935210 D0O2, INDUSTRIAL (PART 20) SIGNAL BOOSTER, we as manufacturer, Andrew Wireless Systems GmbH, Buchdorf declare that the warning below:
WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. and the warning according to RSS-131 Issue 3 WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED licensee to operate this device. AVERTISSEMENT : Ce produit NEST PAS un appareil de CONSOMMATION. II est conu pour tre install par un installateur approuv par un titulaire de licence d@ ISDE. Pour utiliser cet apparel, vous DEVEZ dtenir une LICENCE dISDE ou avoir obtenu le consentement exprs dun titulaire de licence autoris par ISDE. or a combined, from FCC and ISED accepted warning Label WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC (or ISED in Canada) licensees and I qualified installers. You MUST have an FCC LICENSE or the express consent of an FCC licensee to operate this device (or ISED license or licensee consent in Canada). In the USA, unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. AVERTISSEMENT: Ce produit N'EST PAS un appareil de CONSOMMATION. Il est concu pour tre install par un installateur approuv par un titulaire de licence d'ISDE. Pour utiliser cet appareil, vous DEVEZ dtenir une LICENCE d'lSDE ou avoir obtenu le consentement exprs d'un titulaire de licence autoris par ISDE. INTENDED USE: EU AND EFTA COUNTRIES To be sold exclusively to mobile operators or authorized installers, no harmonised frequency bands, operation needs ec Andrew Wireless Systems GmbH Industriering 10; 86675 Buchdorf / Germany Recycling information can be obtained from the WEEE recycling selection at so www.CommScope.com For Patents See www.CS-pat.com ID: 7677757-04 According to KDB 935210 D02, PART 90 SIGNAL BOOSTER SPECIFIC REQUIREMENTS, we as manufacturer, Andrew Wireless Systems GmbH, Buchdorf declare that the warning below:
WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters
(as defined in 47 CFR 90.219) online at www fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. ID: 7837505-00 can be seen at:
- Product itself as label
- Packaging as label
- manual
- data sheet
- sales brochure
- all other electronic media where customer has access Andrew
: ireless Systems GmbH Buchdorf, 24. Oct. 2019 Industriering 10 86675 Buchdort AWS GmbH F.Futter Specialist Reliability Compliance
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-04-28 | 851 ~ 862 | B9B - Part 90 Class B Industrial Booster (non-SMR) | Original Equipment |
2 | 862 ~ 869 | B2I - Part 20 Industrial Booster (CMRS) | ||
3 | 2019-11-21 | 851 ~ 869 | B9A - Part 90 Class A Industrial Booster (non-SMR) |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 | Effective |
2021-04-28
|
||||
1 2 3 |
2019-11-21
|
|||||
1 2 3 | Applicant's complete, legal business name |
Andrew Wireless System
|
||||
1 2 3 | FCC Registration Number (FRN) |
0019152750
|
||||
1 2 3 | Physical Address |
Industriering 10
|
||||
1 2 3 |
Buchdorf, N/A
|
|||||
1 2 3 |
Germany
|
|||||
app s | TCB Information | |||||
1 2 3 | TCB Application Email Address |
S******@phoenix-testlab.de
|
||||
1 2 3 |
v******@phoenix-testlab.de
|
|||||
1 2 3 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
1 2 3 |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
|||||
app s | FCC ID | |||||
1 2 3 | Grantee Code |
XS5
|
||||
1 2 3 | Equipment Product Code |
PSR78A
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 | Name |
W****** O******
|
||||
1 2 3 | Title |
Manager Quality
|
||||
1 2 3 | Telephone Number |
+49-9******** Extension:
|
||||
1 2 3 | Fax Number |
+49-9********
|
||||
1 2 3 |
w******@commscope.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 2 3 | Yes | |||||
1 2 3 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 05/19/2020 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 | Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) | ||||
1 2 3 | B2I - Part 20 Industrial Booster (CMRS) | |||||
1 2 3 | B9A - Part 90 Class A Industrial Booster (non-SMR) | |||||
1 2 3 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Public Safety Repeater | ||||
1 2 3 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | Yes | ||||
1 2 3 | No | |||||
1 2 3 | Modular Equipment Type | Does not apply | ||||
1 2 3 | Purpose / Application is for | Original Equipment | ||||
1 2 3 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 | No | |||||
1 2 3 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 | Grant Comments | Output power listed is the maximum conducted at antenna port. The final ERP is addressed at time of licensing when the antenna gain, antenna height, and loss are jointly considered. Maximum antenna gain and ERP for operations under Part 90.219(e)(1) are limited to 9 dBi and 5 Watt respectively. This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. RF exposure of simultaneous transmission including multiple units is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). This device is approved with the incorporated licensed B9A and B2I transmitter certified under the same FCC ID. | ||||
1 2 3 | Output power listed is the maximum conducted at antenna port. The final ERP is addressed at time of licensing when the antenna gain, antenna height, and loss are jointly considered. Maximum antenna gain and ERP for operations under Part 90.219(e)(1) are limited to 9 dBi and 5 Watt respectively. This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. RF exposure of simultaneous transmission including multiple units is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). | |||||
1 2 3 | Device supports LTE Modulations. Output power listed is the maximum conducted at antenna port. The final ERP is addressed at time of licensing when the antenna gain, antenna height, and loss are jointly considered. Maximum antenna gain and ERP for operations under Part 90.219(e)(1) are limited to 9 dBi and 5 Watt respectively. This filing contains compliance information and test data for incumbent/duly-authorized public safety narrowband operations in Public Safety Broadband (FirstNet) spectrum. RF exposure of simultaneous transmission including multiple units is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). | |||||
1 2 3 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 | Firm Name |
7layers GmbH
|
||||
1 2 3 | Name |
B****** R********
|
||||
1 2 3 | Telephone Number |
0049 ********
|
||||
1 2 3 | Fax Number |
0049 ********
|
||||
1 2 3 |
B******@7layers.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 9 | PF | 758 | 768 | 2.1 | Amp | F3E | |||||||||||||||||||||||||||||||||
1 | 2 | 9 | 758 | 768 | 2.1 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 3 | 9 | 758 | 768 | 2.1 | Amp | D7W | ||||||||||||||||||||||||||||||||||
1 | 4 | 9 | 769 | 775 | 2 | Amp | F3E | ||||||||||||||||||||||||||||||||||
1 | 5 | 9 | 769 | 775 | 2 | Amp | D7W | ||||||||||||||||||||||||||||||||||
1 | 6 | 9 | 769 | 775 | 2 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 7 | 9 | 851 | 862 | 2 | Amp | F3E | ||||||||||||||||||||||||||||||||||
1 | 8 | 9 | 851 | 862 | 2 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 9 | 9 | 851 | 862 | 2 | Amp | D7W | ||||||||||||||||||||||||||||||||||
1 | 1 | 9 | 788 | 798 | 0.5 | Amp | F3E | ||||||||||||||||||||||||||||||||||
1 | 11 | 9 | 788 | 798 | 0.5 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 12 | 9 | 788 | 798 | 0.5 | Amp | D7W | ||||||||||||||||||||||||||||||||||
1 | 13 | 9 | 799 | 805 | 0.5 | Amp | F3E | ||||||||||||||||||||||||||||||||||
1 | 14 | 9 | 799 | 805 | 0.5 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 15 | 9 | 799 | 805 | 0.5 | Amp | D7W | ||||||||||||||||||||||||||||||||||
1 | 16 | 9 | 806 | 817 | 0.5 | Amp | F3E | ||||||||||||||||||||||||||||||||||
1 | 17 | 9 | 806 | 817 | 0.5 | Amp | F1D | ||||||||||||||||||||||||||||||||||
1 | 18 | 9 | 806 | 817 | 0.5 | Amp | D7W | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 90S | 862 | 869 | 3 | Amp | F3E | ||||||||||||||||||||||||||||||||||
2 | 2 | 90S | 862 | 869 | 3 | Amp | F1D | ||||||||||||||||||||||||||||||||||
2 | 3 | 90S | 862 | 869 | 3 | Amp | D7W | ||||||||||||||||||||||||||||||||||
2 | 4 | 90S | 817 | 824 | 0.6 | Amp | F3E | ||||||||||||||||||||||||||||||||||
2 | 5 | 90S | 817 | 824 | 0.6 | Amp | F1D | ||||||||||||||||||||||||||||||||||
2 | 6 | 90S | 817 | 824 | 0.6 | Amp | D7W | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 9 | EF PF | 758 | 768 | 2 | Amp | G7D | |||||||||||||||||||||||||||||||||
3 | 2 | 9 | EF PF | 788 | 789 | 0.5 | Amp | G7D | |||||||||||||||||||||||||||||||||
3 | 3 | 9 | 769 | 775 | 2 | Amp | F3E | ||||||||||||||||||||||||||||||||||
3 | 4 | 9 | 769 | 775 | 2 | Amp | F1D | ||||||||||||||||||||||||||||||||||
3 | 5 | 9 | 769 | 775 | 2 | Amp | D7W | ||||||||||||||||||||||||||||||||||
3 | 6 | 9 | 851 | 869 | 2 | Amp | F3E | ||||||||||||||||||||||||||||||||||
3 | 7 | 9 | 851 | 869 | 2 | Amp | F1D | ||||||||||||||||||||||||||||||||||
3 | 8 | 9 | 851 | 869 | 2 | Amp | D7W | ||||||||||||||||||||||||||||||||||
3 | 9 | 9 | 799 | 805 | 0.5 | Amp | F3E | ||||||||||||||||||||||||||||||||||
3 | 1 | 9 | 799 | 805 | 0.5 | Amp | F1D | ||||||||||||||||||||||||||||||||||
3 | 11 | 9 | 799 | 805 | 0.5 | Amp | D7W | ||||||||||||||||||||||||||||||||||
3 | 12 | 9 | 806 | 824 | 0.5 | Amp | F3E | ||||||||||||||||||||||||||||||||||
3 | 13 | 9 | 806 | 824 | 0.5 | Amp | F1D | ||||||||||||||||||||||||||||||||||
3 | 14 | 9 | 806 | 824 | 0.5 | Amp | D7W |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC