all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Manual 1 | Users Manual | 2.15 MiB | ||||
1 |
|
Manual 2 | Users Manual | 1.46 MiB | ||||
1 | Attestation Statements | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | ID Label/Location Info | |||||||
1 | RF Exposure Info | |||||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | Manual 1 | Users Manual | 2.15 MiB |
ADSL2 Barricade N Draft 11n Wireless 4-port Annex A ADSL2/2+ Modem Router SMC7904WBRA-N Router with built-in ADSL2/2+ Modem From SMCs line of award-winning connectivity solutions 20 Mason Irvine, CA 92618 Phone: (949) 679-8000 August 2007 R.01 F/W 0.11 Information furnished is believed to be accurate and reliable. However, no responsibility is assumed by our company for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of our company. We reserve the right to change specifications at any time without notice. Copyright 2007 by SMC Networks, Inc. 20 Mason Irvine, CA 92618 All rights reserved. Trademarks:
SMC is a registered trademark; and Barricade is a trademark of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders. LIMITED WARRANTY Limited Warranty Statement: SMC Networks, Inc. (SMC) warrants its products to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term. SMC will endeavor to repair or replace any product returned under warranty within 30 days of receipt of the product. The standard limited warranty can be upgraded to a Limited Lifetime* warranty by registering new products within 30 days of purchase from SMC or its Authorized Reseller. Registration can be accomplished via the enclosed product registration card or online via the SMC web site. Failure to register will not affect the standard limited warranty. The Limited Lifetime warranty covers a product during the Life of that Product, which is defined as the period of time during which the product is an Active SMC product. A product is considered to be Active while it is listed on the current SMC price list. As new technologies emerge, older technologies become obsolete and SMC will, at its discretion, replace an older product in its product line with one that incorporates these newer technologies. At that point, the obsolete product is discontinued and is no longer an Active SMC product. A list of discontinued products with their respective dates of discontinuance can be found at:
http://www.smc.com/index.cfm?action=customer_service_warranty. All products that are replaced become the property of SMC. Replacement products may be either new or reconditioned. Any replaced or repaired product carries either a 30-day limited warranty or the remainder of the initial warranty, whichever is longer. SMC is not responsible for any custom software or firmware, configuration information, or memory data of Customer contained in, stored on, or integrated with any products returned to SMC pursuant to any warranty. Products returned to SMC should have any customer-installed accessory or add-on components, such as expansion modules, removed prior to returning the product for replacement. SMC is not responsible for these items if they are returned with the product. Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC. Proof of purchase may be required. Any product returned to SMC without a valid Return Material Authorization (RMA) number clearly marked on the outside of the package will be returned to customer at customers expense. For warranty claims within North America, please call our toll-free customer support number at (800) 762-4968. Customers are responsible for all shipping charges from their facility to SMC. SMC is responsible for return shipping charges from SMC to customer. i LIMITED WARRANTY WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMERS SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMCS OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMERS OR ANY THIRD PERSONS MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD. LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), SHALL SMC BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS.
* SMC will provide warranty service for one year following discontinuance from the active SMC price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-year warranty from date of purchase. SMC Networks, Inc. 20 Mason Irvine, CA 92618 ii COMPLIANCES Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver Increase the separation between the equipment and receiver is connected Consult the dealer or an experienced radio/TV technician for help This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IEEE 802.11b or 802.11g operation of this product in the U.S.A. is firmware-limited to channels 1 through 11. SMC contact for these products in US is:
SMC Networks North America 20 Mason Irvine, CA 92618. USA Tel 800-762-4968 Tony Stramandinoli iii COMPLIANCES FCC - Part 68 This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US: ACYDL01B7904WBRAN. If requested, this number must be provided to the telephone company. The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US: ACYDL01B7904WBRAN. The digits represented by 01 are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details. If your equipment causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But if advance notice is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC. Your telephone company may make changes in it is facilities, equipment, operations or procedures that could affect the proper functioning of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. If you experience trouble with this telephone equipment, Please contact the following address and phone number for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. Company: SMC Networks North America Address: 20 Mason, Irvine, CA 92618. USA Telephone number: 800-762-4968 iv COMPLIANCES CE Mark Declaration of Conformance for EMI and Safety
(EEC) This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following references have been applied in order to prove presumption of compliance with the R&TTE Directive 1999/5/EC:
EN 300 328 EN 301 489 EN 60950-1 SMC contact for these products in Europe is:
SMC Networks Europe, Edificio Conata II, Calle Fructus Gelabert 6-8, 2o, 4a, 08970 - Sant Joan Desp, Barcelona, Spain. Countries of Operation & Conditions of Use in the European Community This device is intended to be operated in all countries of the European Community. Requirements for indoor vs. outdoor operation, license requirements and allowed channels of operation apply in some countries as described below:
Note: The user must use the configuration utility provided with this product to ensure the channels of operation are in conformance with the spectrum usage rules for European Community countries as described below. This device will automatically limit the allowable channels determined by the current country of operation. Incorrectly entering the country of operation may result in illegal operation and may cause harmful interference to other system. The user is obligated to ensure the device is operating according to the channel limitations, indoor/outdoor restrictions and license requirements for each European Community country as described in this document. This device may be operated indoors or outdoors in all countries of the European Community using the 2.4 GHz band: Channels 1 - 13. v COMPLIANCES Declaration of Conformity in Languages of the European Community English Finnish Dutch French Swedish Danish German Greek Italian Hereby, SMC Networks, declares that this Radio LAN device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Valmistaja SMC Networks vakuuttaa tten ett Radio LAN device tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen. Hierbij verklaart SMC Networks dat het toestel Radio LAN device in overeenstemming is met de essentile eisen en de andere relevante bepalingen van richtlijn 1999/5/EG Bij deze SMC Networks dat deze Radio LAN device voldoet aan de essentile eisen en aan de overige relevante bepalingen van Richtlijn 1999/
5/EC. Par la prsente SMC Networks dclare que l'appareil Radio LAN device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE Hrmed intygar SMC Networks att denna Radio LAN device str I verensstmmelse med de vsentliga egenskapskrav och vriga relevanta bestmmelser som framgr av direktiv 1999/5/EG. Undertegnede SMC Networks erklrer herved, at flgende udstyr Radio LAN device overholder de vsentlige krav og vrige relevante krav i direktiv 1999/5/EF Hiermit erklrt SMC Networks, dass sich dieser/diese/dieses Radio LAN device in bereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet".
(BMWi) Hiermit erklrt SMC Networks die bereinstimmung des Gertes Radio LAN device mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG. (Wien) Con la presente SMC Networks dichiara che questo Radio LAN device conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. vi COMPLIANCES Spanish Por medio de la presente SMC Networks declara que el Radio LAN device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE Portuguese SMC Networks declara que este Radio LAN device est conforme com os requisitos essenciais e outras disposies da Directiva 1999/5/CE. NCC Statement
(1)
(2)
(3)
( 4 )
(5) , vii COMPLIANCES Safety Compliance Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfltig durch. 2. Heben Sie diese Anleitung fr den spteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gert vom Stromnetz zu trennen. Verwenden Sie keine Flssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung. 4. Die Netzanschlu steckdose soll nahe dem Gert angebracht und leicht zugnglich sein. 5. Das Gert ist vor Feuchtigkeit zu schtzen. 6. Bei der Aufstellung des Gertes ist auf sicheren Stand zu achten. Ein Kippen oder Fallen knnte Beschdigungen hervorrufen. 7. Die Belftungsffnungen dienen der Luftzirkulation, die das Gert vor berhitzung schtzt. Sorgen Sie dafr, da diese ffnungen nicht abgedeckt werden. 8. Beachten Sie beim Anschlu an das Stromnetz die Anschluwerte. 9. Verlegen Sie die Netzanschluleitung so, da niemand darber fallen kann. Es sollte auch nichts auf der Leitung abgestellt werden. 10. Alle Hinweise und Warnungen, die sich am Gert befinden, sind zu beachten. 11. Wird das Gert ber einen lngeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer berspannung eine Beschdigung vermieden. 12. Durch die Lftungsffnungen drfen niemals Gegenstnde oder Flssigkeiten in das Gert gelangen. Dies knnte einen Brand bzw. elektrischen Schlag auslsen. 13. ffnen sie niemals das Gert. Das Gert darf aus Grnden der elektrischen Sicherheit nur von authorisiertem Servicepersonal geffnet werden. 14. Wenn folgende Situationen auftreten ist das Gert vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu berprfen:
a. Netzkabel oder Netzstecker sind beschdigt. b. Flssigkeit ist in das Gert eingedrungen. c. Das Gert war Feuchtigkeit ausgesetzt. d. Wenn das Gert nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen. e. Das Gert ist gefallen und/oder das Gehuse ist beschdigt. f. Wenn das Gert deutliche Anzeichen eines Defektes aufweist. 15. Zum Netzanschlu dieses Gertes ist eine geprfte Leitung zu verwenden. Fr einen Nennstrom bis 6 A und einem Gertegewicht grer 3 kg ist eine Leitung nicht leichter als H05VV-F, 3G, 0.75 mm2 einzusetzen. Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 betrgt 70 dB(A) oder weniger. viii TABLE OF CONTENTS Introduction . 1-1 About the Barricade . 1-1 Features and Benefits . 1-2 Applications . 1-3 Installation . 2-1 Package Contents . 2-1 System Requirements . 2-2 Hardware Description . 2-2 LED Indicators . 2-3 Rear Panel . 2-5 ISP Settings . 2-6 Connect the System . 2-6 Connect the ADSL Line . 2-6 Attach to Your Network Using Ethernet Cabling . 2-7 Connect the Power Adapter . 2-7 Connection Illustration . 2-8 Configuring Client PC . 3-1 TCP/IP Configuration . 3-1 Windows 2000 . 3-2 Disable HTTP Proxy . 3-3 Obtain IP Settings from Your Barricade . 3-3 Windows XP . 3-5 Disable HTTP Proxy . 3-5 Obtain IP Settings from Your Barricade . 3-6 Configuring Your Macintosh Computer . 3-7 Disable HTTP Proxy . 3-8 vii TABLE OF CONTENTS Configuring the Barricade . 4-1 Navigating the Management Interface . 4-2 Making Configuration Changes . 4-2 Setup Wizard . 4-3 Time Zone . 4-3 Wireless Settings . 4-4 ADSL Settings . 4-6 Parameter Setting - Country or ISP Not Listed . 4-7 Summary . 4-15 Configuration parameters . 4-17 System . 4-19 WAN . 4-22 LAN . 4-31 Wireless . 4-32 NAT . 4-44 Routing . 4-49 Firewall . 4-53 SNMP . 4-66 UPnP . 4-69 ADSL . 4-70 DDNS . 4-73 Tools . 4-74 Status . 4-79 Finding the MAC address of a Network Card . 4-82 Windows 2000/XP . 4-82 Macintosh . 4-82 Linux . 4-82 viii TABLE OF CONTENTS Troubleshooting . A-1 Cables . B-1 Ethernet Cable . B-1 Specifications . B-1 Wiring Conventions . B-1 RJ-45 Port Connection . B-2 Pin Assignments . B-3 ADSL Cable . B-5 Specifications . B-5 Wiring Conventions . B-5 Specifications . C-1 ix CHAPTER 1 INTRODUCTION Congratulations on your purchase of the 802.11n ADSL2 BarricadeTM, hereafter referred to as the Barricade. We are proud to provide you with a powerful yet simple communication device for connecting your local area network (LAN) to the Internet. For those who want to surf the Internet in the most secure way, this router provides a convenient and powerful solution. About the Barricade The Barricade provides Internet access to multiple users by sharing a single-user account. It is simple to configure and can be up and running in minutes. The Barricade is compliant with the next generation IEEE 802.11n draft v2.0 specification while maintaining full backwards compatibility with the current 802.11b/g standards. 802.11n builds upon previous 802.11 standards by adding MIMO
(multiple-input multiple-output). MIMO uses multiple transmitter and receiver antennas to allow for increased data throughputs for up to 300 Mbps. This provides sufficient bandwidth to stream HD video, listen to digital music, play online games, transfer large files, make VoIP calls and surf the Internet simultaneously. 1-1 INTRODUCTION Features and Benefits Intergrated ADSL modem for connecting to ADSL line Fully backward compatible with 802.11 g/802.11 b networks Wireless speeds up to 300 Mbps. Increased speed and coverage - up to 5 times the speed of 802.11g Local network connection via four 10/100 Mbps Ethernet ports DHCP for dynamic IP configuration, and DNS Proxy/Relay for domain name mapping Firewall with Stateful Packet Inspection, client privileges, intrusion detection, and NAT NAT also enables multi-user Internet access via a single user account, and virtual server functionality (providing protected access to Internet services such as web, FTP, e-mail, and Telnet) VPN pass-through (IPSec-ESP Tunnel mode, L2TP, PPTP) User-definable application sensing tunnel supports applications requiring multiple connections Easy setup through a web browser on any operating system that supports TCP/IP Compatible with all popular Internet applications 1-2 Applications APPLICATIONS Many advanced networking features are provided by the Barricade:
Wired and Wireless LAN The Barricade provides connectivity to 10/100 Mbps devices, and wireless connection speed up to 300 Mbps. This router is fully compliant with specifications defined in IEEE 802.11b, IEEE 802.11g and IEEE 802.11n draft v2.0 standards, making it easy to create a network in small offices or homes.
Internet Access This device supports Internet access through an ADSL connection. Since many DSL providers use PPPoE to establish communications with end users, the Barricade includes built-in clients for these protocols, eliminating the need to install these services on your computer.
Shared IP Address Using only one ISP account, multiple users on your network can access the Internet at the same time.
Virtual Server If you have a fixed IP address, you can set the Barricade to act as a virtual host for network address translation. Remote users access various services at your site using a constant IP address. Then, depending on the requested service (or port number), the Barricade can route the request to the appropriate server (at another internal IP address). This secures your network from direct attack by hackers, and provides more flexible management by allowing you to change internal IP addresses without affecting outside access to your network. 1-3 INTRODUCTION
DMZ Host Support Allows a networked computer to be fully exposed to the Internet. This function is used when NAT and firewall security prevent an Internet application from functioning correctly.
Security The Barricade supports security features that deny Internet access to specified users, or filter all requests for specific services that the administrator does not want to serve. The Barricades firewall also blocks common hacker attacks, including IP Spoofing, Land Attack, Ping of Death, IP with zero length, Smurf Attack, UDP port loopback, Snork Attack, TCP null scan, and TCP SYN flooding.
Virtual Private Network (VPN) The Barricade supports three of the most commonly used VPN protocols PPTP, L2TP, and IPSec. These protocols allow remote users to establish a secure connection to their corporate network. If your service provider supports VPNs, then these protocols can be used to create an authenticated and encrypted tunnel for passing secure data over the Internet (i.e., a traditionally shared data network). The VPN protocols supported by the Barricade are briefly described below. Point-to-Point Tunneling Protocol Provides a secure tunnel for remote client access to a PPTP security gateway. PPTP includes provisions for call origination and flow control required by ISPs. L2TP merges the best features of PPTP and L2F Like PPTP, L2TP requires that the ISPs routers support the protocol. IP Security Provides IP network-layer encryption. IPSec can support large encryption networks (such as the Internet) by using digital certificates for device authentication. 1-4 CHAPTER 2 INSTALLATION Before installing the BarricadeTM, verify that you have all the items listed under the Package Contents list. If any of the items are missing or damaged, contact your local distributor. Also be sure that you have all the necessary cabling before installing the Barricade. After installing the Barricade, refer to Configuring the BarricadeTM on page 4-1. Package Contents After unpacking, check the contents of the box to be sure you have received the following components:
ADSL2 Barricade N (SMC7904WBRA-N) Power adapter One CAT-5 Ethernet cable (RJ-45) One Telephone patch cables (RJ-11) Documentation CD One Warranty information card Immediately inform your dealer in the event of any incorrect, missing, or damaged parts. If possible, please retain the carton and original packing materials in case there is a need to return the product. 2-1 INSTALLATION System Requirements You must meet the following minimum requirements:
ADSL Internet service 2.4 GHz 802.11n draft wireless adapter or 2.4 GHz 802.11b/g wireless adapter installed on each PC. Alternatively an Ethernet adapter can be used. Internet Explorer 5.5 or above, Netscape 4.7 or above, Mozilla Firefox 1.0 or above Hardware Description The Barricade contains an integrated ADSL2+ modem and connects to the Internet or to a remote site using its WAN port. This device can be connected directly to your PC or to a local area network using any of the four Fast Ethernet LAN ports. Access speed to the Internet depends on your service type. Full-rate ADSL provides up to 8 Mbps downstream and 1 Mbps upstream. G.lite (or splitterless) ADSL provides up to 1.5 Mbps downstream and 512 kbps upstream. ADSL2+ Provides up to 24 Mbps downstream and 1 Mbps upstream. However, you should note that the actual rate provided by specific service providers may vary dramatically from these upper limits. Data passing between devices connected to your local area network can run at up to 100 Mbps over the Fast Ethernet ports. Data rates up to 300 Mbps are possible with the 802.11n function enabled. The Barricade includes an LED display on the front panel for system power and port indications that simplifies installation and network troubleshooting. 2-2 HARDWARE DESCRIPTION LED Indicators The power and port LED indicators and the WPS button on the top panel are illustrated in the following figure and table. Figure 2-1. Top View Item Power ADSL Sync ADSL Data WLAN Status On Off On Flashing Off Blinking Off On Blinking Description The Barricade is receiving power. Normal operation. Power off or failure. ADSL connection is functioning correctly. The Barricade is establishing an ADSL link. ADSL connection is not established. ADSL port is sending/receiving data. No data is being transferred. Wireless link established. Data is been transmitted via wireless link. 2-3 INSTALLATION Status Off On Fast Flash Slow Flash Off On Flashing Off Item WLAN WPS LAN
(4 LEDs) WPS button Description No wireless link. Successful WPS connection. WPS connection failed. The Barricade is establishing WPS connection. WPS function is off. Ethernet connection is established. The indicated LAN port is sending or receiving data. There is no LAN connection on the port. This button is located on the top panel, press this button for at least 4 seconds when activating the WPS function. Note: with successful WPS connection, the WPS LED indicator will be off after 300 seconds. 2-4 HARDWARE DESCRIPTION Rear Panel SMC7904BRA-N contains the following ports on the rear panel:
Figure 2-2. Rear Panel Item ADSL Port LAN1 to LAN4 Reset Button Power Inlet Power On/Off switch Description Connect your ADSL line to this port (RJ-11 port). Fast Ethernet ports (RJ-45). Connect devices on your local area network to these ports (i.e., a PC, hub, or switch). Use this button to reset the Barricade and restore the default factory settings. To reset without losing configuration settings, see Reset on page 4-78. Connect the included power adapter to this inlet. Warning: Using the wrong type of power adapter may damage the Barricade. Use this switch to turn on/off the power. 2-5 INSTALLATION ISP Settings Please collect the following information from your ISP before setting up the Barricade:
ISP account user name and password Protocol, encapsulation and VPI/VCI circuit numbers DNS server address IP address, subnet mask and default gateway (for fixed IP users only) Connect the System The Barricade can be positioned at any convenient location in your office or home. No special wiring or cooling requirements are needed. You should, however, comply with the following guidelines:
Keep the Barricade away from any heating devices. Do not place the Barricade in a dusty or wet environment. You should also remember to turn off the power, remove the power cord from the outlet, and keep your hands dry when you install the Barricade. Connect the ADSL Line Connect the supplied ADSL cable from the port labelled ADSL on the Splitter/Microfilter to the ADSL port on your Barricade. When inserting the plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Note: The ADSL port of SMC7904WBRA-N is RJ-11. 2-6 CONNECT THE SYSTEM Attach to Your Network Using Ethernet Cabling The four LAN ports on the Barricade auto-negotiate the connection speed to 10 Mbps or 100 Mbps, as well as the transmission mode to half duplex or full duplex. Use RJ-45 cables to connect any of the four LAN ports on the Barricade to an Ethernet adapter on your PC. Otherwise, cascade any of the LAN ports on the Barricade to an Ethernet hub or switch, and then connect your PC or other network equipment to the hub or switch. When inserting an RJ-45 connector, be sure the tab on the connector clicks into position to ensure that it is properly seated. Warning: Do not plug a phone jack connector into an RJ-45 port. This may damage the Barricade. Note: Use 100-ohm shielded or unshielded twisted-pair cable with RJ-45 connectors for all Ethernet ports. Category 5 cable is recommended. Make sure each twisted-pair cable length does not exceed 100 meters (328 feet). Connect the Power Adapter Plug the power adapter into the power socket on the rear of the Barricade, and the other end into a power outlet. Check the power indicator on the front panel is lit. If the power indicator is not lit, refer to Troubleshooting on page A-1. In case of a power input failure, the Barricade will automatically restart and begin to operate once the input power is restored. 2-7 INSTALLATION Connection Illustration The connection diagram shows how to connect the Barricade. 2-8 CHAPTER 3 CONFIGURING CLIENT PC After completing hardware setup by connecting all your network devices, you need to configure your computer to connect to the Barricade. See:
Windows 2000 on page 3-2 Windows XP on page 3-5 Configuring Your Macintosh Computer on page 3-7 depending on your operating system. TCP/IP Configuration To access the Internet through the Barricade, you must configure the network settings of the computers on your LAN to use the same IP subnet as the Barricade. The default IP settings for the Barricade are:
IP Address: 192.168.2.1 Subnet Mask: 255.255.255.0 Note: These settings can be changed to fit your network requirements, but you must first configure at least one computer to access the Barricades web configuration interface in order to make the required changes. (See Configuring the Barricade on page 4-1 for instruction on configuring the Barricade.) 3-1 CONFIGURING CLIENT PC Windows 2000 1. On the Windows desktop, click Start/Settings/Network and Dial-Up Connections. 2. Click the icon that corresponds to the connection to your Barricade. 3. The connection status screen will open. Click Properties. 4. Double-click Internet Protocol (TCP/IP). 5. If Obtain an IP address automatically and Obtain DNS server address automatically are already selected, your computer is already configured for DHCP. If not, select this option. 3-2 WINDOWS 2000 Disable HTTP Proxy You need to verify that the HTTP Proxy feature of your web browser is disabled. This is so that your browser can view the Barricades HTML configuration pages. See page 3-5 for details. Obtain IP Settings from Your Barricade Now that you have configured your computer to connect to your Barricade, it needs to obtain new network settings. By releasing old DHCP IP settings and renewing them with settings from your Barricade, you can verify that you have configured your computer correctly. 1. On the Windows desktop, click Start/Programs/
Accessories/
Command Prompt. 2. In the Command Prompt window, type IPCONFIG /RELEASE and press the ENTER key. 3-3 CONFIGURING CLIENT PC 3. Type IPCONFIG /RENEW and press the ENTER key. Verify that your IP Address is now 192.168.2.xxx, your Subnet Mask is 255.255.255.0 and your Default Gateway is 192.168.2.1. These values confirm that your ADSL Router is functioning. 4. Close the Command Prompt window. Your computer is now configured to connect to the Barricade. 3-4 WINDOWS XP Windows XP 1. On the Windows desktop, click Start/Control Panel. 2. In the Control Panel window, click Network and Internet Connections. 3. The Network Connections window will open. Double-click the connection for this device. 4. On the connection status screen, click Properties. 5. Double-click Internet Protocol (TCP/IP). 6. If Obtain an IP address automatically and Obtain DNS server address automatically are already selected, your computer is already configured for DHCP. If not, select the options. Disable HTTP Proxy You need to verify that the HTTP Proxy feature of your web browser is disabled. This is so that your browser can view the Barricades HTML configuration pages. Follow these steps to disable the HTTP proxy:
Open your web browser, go to Tools/Internet Options, select the Connections tab, click LAN Setting. Make sure the checkbox for Use a proxy server for your LAN is not checked. 3-5 CONFIGURING CLIENT PC Obtain IP Settings from Your Barricade Now that you have configured your computer to connect to your Barricade, it needs to obtain new network settings. By releasing old DHCP IP settings and renewing them with settings from your Barricade, you can verify that you have configured your computer correctly. 1. On the Windows desktop, click Start/Programs/Accessories/
Command Prompt. 2. In the Command Prompt window, type IPCONFIG /RELEASE and press the ENTER key. 3. Type IPCONFIG /RENEW and press the ENTER key. Verify that your IP Address is now 192.168.2.xxx, your Subnet Mask is 255.255.255.0 and your Default Gateway is 192.168.2.1. These values confirm that your ADSL router is functioning. 4. Close the Command Prompt window. Your computer is now configured to connect to the Barricade. 3-6 CONFIGURING YOUR MACINTOSH COMPUTER Configuring Your Macintosh Computer You may find that the instructions here do not exactly match your operating system. This is because these steps and screenshots were created using Mac OS 10.2. Mac OS 7.x and above are similar, but may not be identical to Mac OS 10.2. Follow these instructions:
1. Pull down the Apple Menu
. Click System Preferences. 2. Double-click the Network icon in the Systems Preferences window. 3-7 CONFIGURING CLIENT PC 3. If Using DHCP Server is already selected in the Configure field, your computer is already configured for DHCP. If not, select this Option. 4. Your new settings are shown on the TCP/IP tab. Verify that your IP Address is now 192.168.2.xxx, your Subnet Mask is 255.255.255.0 and your Default Gateway is 192.168.2.1. These values confirm that your Barricade is functioning. 5. Close the Network window. Now your computer is configured to connect to the Barricade. Disable HTTP Proxy You need to verify that the HTTP Proxy feature of your web browser is disabled. This is so that your browser can view the Barricades HTML configuration pages. The following steps are for Internet Explorer. Internet Explorer 1. Open Internet Explorer and click Explorer/
Preferences. 2. In the Internet Explorer Preferences window, under Network, select Proxies. 3-8 CONFIGURING YOUR MACINTOSH COMPUTER 3. Uncheck all check boxes and click OK. 3-9 CHAPTER 4 CONFIGURING THE BARRICADE After you have configured TCP/IP on a client computer, you can configure the Barricade using your web browser. To access the Barricades management interface, enter the default IP address in your web browser: http://192.168.2.1. Enter the default password: smcadmin, and click LOGIN. Note: Password is case sensitive. 4-1 CONFIGURING THE BARRICADE Navigating the Management Interface The Barricades management interface consists of a Setup Wizard and 13 menu items. Use the Setup Wizard to quickly set up the Barricade. Go to SETUP WIZARD on page 4-3 for details. For configuration details of the 13 menu items, refer to Configuration parameters on page 4-17. Making Configuration Changes Configurable parameters have a dialog box or a drop-down menu. Once a configuration change has been made on a screen, click the APPLY or SAVE SETTINGS or NEXT button at the bottom of the screen to enable the new setting. Note: To ensure proper screen refresh after a command entry, be sure that Internet Explorer 5.5 is configured as follows: Under the menu Tools/Internet Options/General/Temporary Internet Files/Settings, the setting for Check for newer versions of stored pages should be Every visit to the page. 4-2 SETUP WIZARD SETUP WIZARD Time Zone Click on SETUP WIZARD and NEXT, you will see the time zone screen. Select your local time zone from the drop down menu. This information is used for log entries and client filtering. If you want to automatically synchronize the ADSL router with a public time server, check the Enable Automatic Time Server Maintenance box. Select the desired servers from the drop down menu. Click NEXT to continue. 4-3 CONFIGURING THE BARRICADE Wireless Settings Configure the wireless settings on this screen. Parameter SSID SSID Broadcast Wireless Mode Description This is the Service Set ID. The SSID must be the same on the router and all of its wireless clients. Select to enable/disable the brocasting of SSID, turning off the brocasting of SSID increases your network security. This device supports 11n, 11g and 11b wireless networks. Make your selection depending on the type of wireless network that you have. SMC recommend using Mixed 802.11n, 802.11g and 802.11b to provide compatibility with 11n, 11g and 11b wireless clients. 4-4 Parameter Channel Bandwidth Extension Channel SETUP WIZARD Description The radio channel used by the wireless router and its clients to communicate with each other. This channel must be the same on the router and all of its wireless clients. The router will automatically assign itself a radio channel, or you may select one manually. Select the bandwidth:
20 MHz: Sets the operation bandwidth as 20 MHz. when 20 MHz is selected, there would be no extension channel available. 20/40 MHz: Allows automatic detection of the operation bandwidth between 20 and 40 MHz. Choosing this mode allows you to use the extension channel. This is the optional channel for use. Setting the Bandwith to 20/40 MHz allows you to use this extension channel as the secondary channel for doubling the bandwith of your wireless network. Notes: 1. When the main or primary channel is set to 1, channel 5 will be used as the extension channel. If the main channel is set to 9, channel 5, or channel 13 can be used as the extension channel. 2. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user. 4-5 CONFIGURING THE BARRICADE ADSL Settings Select your Country and Internet Service Provider. This will automatically configure the Barricade with the correct Protocol, Encapsulation and VPI/VCI settings for your ISP. If your ISP uses Protocols PPPoA or PPPoE you will need to enter the username and password supplied by your ISP. If your ISP uses Protocol RFC1483 Routed you will need to enter the IP address, Subnet Mask, and Default Gateway supplied by your ISP. If your Country or Internet Service Provider is not listed in this screen, you will need to manually enter settings. Go to Parameter Setting -
Country or ISP Not Listed on page 4-7 in the manual. Note: If your ISP has not provided you with a DNS address and the protocol is PPPoA, PPPoE or 1483 Bridging, you can leave this field blank. The Barricade will then automatically obtain the DNS address. Click NEXT to continue. 4-6 SETUP WIZARD Parameter Setting - Country or ISP Not Listed If your Country or Internet Service Provider is not listed, select Other. This will allow you to manually configure your ISP settings. For manual configuration you will need to know the Protocol, DNS Server, Encapsulation and VPI/VCI settings used by your ISP. If you have a static IP address you will also need to know the IP address, Subnet Mask and Gateway address. Please contact your ISP for these details if you do not already have them. After selecting Other, then select the Protocol that your ISP uses from the drop down menu. 4-7 CONFIGURING THE BARRICADE PPPoE Parameter VPI/VCI Encapsulation Username Password Confirm Password Description Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down menu. Enter user name provided by your ISP. Enter password provided by your ISP. Confirm password Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the settings. 4-8 PPPoA SETUP WIZARD Parameter VPI/VCI Encapsulation Username Password Confirm Password Description Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down list. Enter user name provided by your ISP. Enter password provided by your ISP. Confirm password Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the settings. 4-9 CONFIGURING THE BARRICADE 1483 Bridging (DHCP) Parameter DNS Server VPI/VCI Encapsulation Description Enter the DNS Server IP address provided by your ISP. If your ISP has not provided you with a DNS address, leave this field blank. The Barricade will automatically obtain the DNS address from your ISP. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down menu. Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the setting. 4-10 1483 Bridging (Static) SETUP WIZARD Parameter IP Address Subnet Mask Default Gateway DNS Server VPI/VCI Encapsulation Description Enter your ISP supplied static IP address here Enter the subnet mask address provided by your ISP. Enter the gateway address provided by your ISP. Enter the DNS Server IP address provided by your ISP. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down list. Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the settings. 4-11 CONFIGURING THE BARRICADE 1483 Routing Parameter IP Address Subnet Mask Default Gateway DNS Server VPI/VCI Encapsulation Description Enter the IP address provided by your ISP. Enter the subnet mask address provided by your ISP. Enter the gateway address provided by your ISP. Enter the DNS Server IP address provided by your ISP. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down menu. Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the settings. 4-12 SETUP WIZARD Bridging Parameter Management IP Address VPI/VCI Encapsulation Description Management IP address of the Barricade
(Default:192.168.2.1). When configured in
"Bridging" mode you will be able to manage the Barricade using this IP address. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down menu. Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the settings. 4-13 CONFIGURING THE BARRICADE 1483 Routing (DHCP) Parameter DNS Server VPI/VCI Encapsulation Description Enter the DNS Server IP address provided by your ISP. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down menu. Click NEXT to continue to the Confirm settings screen. Go to Summary on page 4-15 in the manual for details about the settings. 4-14 SETUP WIZARD Summary The summary screen shows values of the configuration parameters. Check ADSL operation mode (WAN), Network Layer Parameters (WAN) and ISP parameters are correct. Parameter Wireless Parameters SSID SSID Broadcast Wireless mode Channel Time Zone Parameters Description Service Set ID, SSID must be the same on the Router, and all its wireless clients. Enable SSID broadcasting on the wireless network for easy connection for the wireless clients. Disable SSID broadcast for increased security. The Router supports 11n, 11g, and 11b wireless networks. This is the radio channel used for wireless communication. Time Zone NTP Primary server Secondary server This is the time zone that you have selected. Enable or disable of the Network time protocol. The IP address of the time server. The IP address of the time server. 4-15 CONFIGURING THE BARRICADE Parameter ADSL Operation Mode (WAN) Description ISP Protocol VPI/VCI The name of the ISP you have selected from list. The WAN protocol of your ISP. If you are unsure if the selected protocol is correct check with your ISP. Virtual Path Identifier (VPI) and Virtual Circuit Identifier
(VCI). If you are unsure the VPI/VCI values are correct check with your ISP. AAL5 Encapsulation Shows the packet encapsulation type. If you are unsure the selected Encapsulation is correct check with your ISP. Go to page 4-21 for a detailed description. Network Layer Parameters (WAN) IP Address Subnet Mask Default Gateway DNS Server ISP Parameters Username Password WAN IP address (only displayed if you have static IP). WAN subnet mask (only displayed if you have static IP). WAN gateway (only displayed if you have static IP). The IP address of the DNS server. If the DNS address field was left blank in previous steps the address will be displayed as 0.0.0.0. The ISP assigned user name. The password (hidden). If the parameters are correct, click FINISH to save these settings. Your Barricade is now set up. Go to Troubleshooting on page A-1 if you cannot make a connection to the Internet. 4-16 CONFIGURATION PARAMETERS Configuration parameters There are 13 main menu items located on the left side of the screen. Each main menu item is described in the following table. Menu System WAN LAN Wireless NAT Routing Firewall SNMP UPnP ADSL DDNS Description Sets the local time zone, the password for administrator access, and the IP address of a PC that will be allowed to manage the Barricade remotely. Configures the Internet connection settings. Sets the TCP/IP configuration for the Barricade LAN interface and DHCP clients. Configure the wireless parameters. Configures Address Mapping, virtual server and special applications. Sets the routing parameters and displays the current routing table. Configures a variety of security and specialized functions including:
Access Control, URL blocking, Internet access control scheduling, intruder detection, and DMZ. Community string and trap server settings. Enable/disable the Universal Plug and Play function. Sets the ADSL operation type and shows the ADSL status. Configures Dynamic DNS function. 4-17 CONFIGURING THE BARRICADE Menu Tools Status Description Contains options to backup & restore the current configuration, restore all configuration settings to the factory defaults, update system firmware, or reset the system. Provides WAN connection type and status, firmware and hardware version numbers, system IP settings, as well as DHCP, NAT, and firewall information. Displays the number of attached clients, the firmware versions, the physical MAC address for each media interface, and the hardware version and serial number. Shows the security and DHCP client log. 4-18 CONFIGURATION PARAMETERS System Time Zone Select your local time zone from the drop down menu. This information is used for log entries and client filtering. For accurate timing of log entries and system events, you need to set the time zone. Select your time zone from the drop down menu. If daylight savings is used in your area, check the box to enable the function, and select the start/end dates. If you want to automatically synchronize the ADSL router with a public time server, check the Enable Automatic Time Server Maintenance box. Select the desired servers from the drop down menu. 4-19 CONFIGURING THE BARRICADE Password Settings Use this screen to change the password for accessing the management interface. Passwords can contain from 3~12 alphanumeric characters and are case sensitive. Note: If you lost the password, or you cannot gain access to the user interface, press the blue reset button on the rear panel, holding it down for at least 10 seconds to restore the factory defaults. The default password is smcadmin. Enter a maximum Idle Time Out (in minutes) to define a maximum period of time for which the login session is maintained during inactivity. If the connection is inactive for longer than the maximum idle time, it will perform system logout, and you have to log in again to access the management interface. (Default: 10 minutes) 4-20 CONFIGURATION PARAMETERS Remote Management By default, management access is only available to users on your local network. However, you can also manage the Barricade from a remote host by entering the IP address of a remote computer on this screen. Check the Enabled check box, and enter the IP address of the Host Address and click Save Settings. Note: If you enable this function and specify an IP address of 0.0.0.0, any remote host can manage the Barricade. For remote management via WAN IP address you need to connect using port 8080. Simply enter WAN IP address followed by:8080, for example, 211.20.16.1:8080. 4-21 CONFIGURING THE BARRICADE WAN Specify the WAN connection parameters provided by your Internet Service Provider (ISP). The following three items are configurable:
ATM PVC Clone MAC DNS 4-22 CONFIGURATION PARAMETERS ATM PVC To configure your Internet Connection settings, select ATM PVC, then VC1. Click the VC to set the detailed parameters. The Barricade can support up to 8 Virtual Circuits (VC's). Multiple VC's, in general, are only used in the case of Triple Play
(Internet/Voice/Video) services. Example: VC1 = Internet, VC2 = Voice, VC3 = Video. Unless stated by your ISP, you will use a single VC. In this case "VC1"should be used. Parameter VC1 to VC8 VPI/VCI Encapsulation Description Click on the desired VC to configure the connection parameters. Displays the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) configured for the corresponding VC. Displays the Encapsulation configured for the corresponding VC. Encapsulation specifies how to handle multiple protocols at the ATM transport layer. VC-MUX: Point-to-Point Protocol over ATM Virtual Circuit Multiplexer (null encapsulation) allows only one protocol running per virtual circuit with less overhead. LLC: Point-to-Point Protocol over ATM Logical Link Control (LLC) allows multiple protocols running over one virtual circuit (using slightly more overhead). Protocol Displays the Protocol configured for the corresponding VC. 4-23 CONFIGURING THE BARRICADE ATM Interface 1483 Bridging Enter the settings provided by your ISP. In Bridging mode the Barricade will act as a bridge passing the IP addressing directly to the attached client PC. Parameter VPI/VCI Encapsulation QoS Class PCR/SCR/MBS Description Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop-down menu. ATM QoS classes including CBR, UBR and VBR QoS Parameters - PCR (Peak Cell Rate), SCR
(Sustainable Cell Rate) and MBS (Maximum Burst Size) are configurable. 4-24 CONFIGURATION PARAMETERS PPPoA Parameter VPI/VCI Encapsulation QoS Class PCR/SCR/MBS IP assigned by ISP IP Address Subnet Mask Connect Type Idle Time
(Minute) Username Password Description Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop-down menu. ATM QoS classes including CBR, UBR and VBR QoS Parameters - PCR, SCR and MBS are configurable. Select Yes if the IP address was provided by your ISP Enter the IP address provided by your ISP. For dynamic IP leave this field blank. Enter the subnet mask address provided by your ISP. For dynamic IP leave this field blank. Sets connection mode to Always connected, Auto-Triggered by traffic or Manual connection. For flat rate services use Always connected. Enter the maximum idle time for the Internet connection. After this time has been exceeded the connection will be terminated. This setting only applies when the Connect Type is set to Auto-Triggered by traffic. Enter user name. Enter password. 4-25
1 | Manual 2 | Users Manual | 1.46 MiB |
CONFIGURING THE BARRICADE Parameter Confirm Password MTU Description Confirm password Leave the Maximum Transmission Unit (MTU) at the default value unless instructed by your ISP 1483 Routing Parameter IP Address Subnet Mask Default Gateway VPI/VCI Encapsulation QoS Class PCR/SCR/MBS DHCP Client Description Enter the IP address provided by your ISP. Enter the subnet mask address provided by your ISP. Enter the gateway address provided by your ISP. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop down list. ATM QoS classes including CBR, UBR and VBR QoS Parameters - PCR, SCR and MBS are configurable. Check the box if your ISP assigns an IP address dynamically. 4-26 CONFIGURATION PARAMETERS PPPoE Parameter VPI/VCI Encapsulation QoS Class PCR/SCR/MBS IP assigned by ISP IP Address Subnet Mask Connect Type Idle Time
(Minute) Username Password Description Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop-down menu. ATM QoS classes including CBR, UBR and VBR QoS Parameters - PCR, SCR and MBS are configurable. Select yes, if your ISP assigns IP address dynamically. If you have selected No in the previous field, type in the IP address provided by your ISP. Enter the subnet mask address provided by your ISP. Sets connection mode to Always connected, Auto-Triggered by traffic or Manual connection. For flat rate services use Always connected. Enter the maximum idle time for the Internet connection. After this time has been exceeded the connection will be terminated. This setting only applies when the Connect Type is set to Auto-Triggered by traffic. Enter user name. Enter password. 4-27 CONFIGURING THE BARRICADE Parameter Confirm Password MTU Description Confirm password Leave the Maximum Transmission Unit (MTU) at the default value unless instructed by your ISP. IP Over RFC1483 bridged Parameter IP Address Subnet Mask Default Gateway VPI/VCI Encapsulation QoS Class PCR/SCR/MBS DHCP Client Description Enter the IP address provided by your ISP. Enter the subnet mask address provided by your ISP. Enter the gateway address provided by your ISP. Enter the Virtual Path Identifier (VPI) and Virtual Circuit Identifier (VCI) supplied by your ISP. Select the encapsulation used by ISP from the drop-down menu. ATM QoS classes including CBR, UBR and VBR QoS Parameters - PCR, SCR and MBS are configurable. Check the box if your ISP assigns an IP address dynamically. 4-28 CONFIGURATION PARAMETERS Clone MAC Address Some ISPs require you to register your MAC address with them. If this is the case, and you have previously registered the MAC address of another device, the MAC address of the Barricade must be changed to the MAC address that you have registered with your ISP. 4-29 CONFIGURING THE BARRICADE DNS A Domain Name Server (DNS) is an index of IP addresses and Web addresses. If you type a Web address into your browser, such as www.smc.com, a DNS server will find that name in its index and find the matching IP address: xxx.xxx.xxx.xxx. Most ISPs provide a DNS server for speed and convenience. Since your Service Provider may connect to the Internet with dynamic IP settings, it is likely that the DNS server IP's are also provided dynamically. However, if there is a DNS server that you would rather use, you need to specify the IP address here. 4-30 CONFIGURATION PARAMETERS LAN The LAN settings menu allows you to change the default IP address of the Barricade, modify the DHCP server settings. Parameter LAN IP IP Address IP Subnet Mask DHCP Server Lease Time IP Address Pool Start IP Address/
End IP address Domain Name Description The IP address of the Barricade. The subnet mask of the Barricade. This option allows you to enable or disable the DHCP server function. By default DHCP is enabled. Allows you to select a pre-defined lease time for IP addresses assigned using DHCP. For home networks this may be set to Forever, which means there is no time limit on the IP address lease. Specify the start/end IP address of the DHCP pool. Do not include the gateway address of the Barricade in the client address pool. If you change the pool range, make sure the first three octets match the gateways IP address, i.e., 192.168.2.xxx. If your network uses a domain name, enter it here. Otherwise, leave this field blank. 4-31 CONFIGURING THE BARRICADE Wireless The router also operates as a wireless access point, allowing wireless computers to communicate with each other. To configure this function, all you need to do is enable the wireless function, define the radio channel, the domain identifier, and the security options. Enable or disable Wireless module function: select to enable or disable the wireless function. 4-32 CONFIGURATION PARAMETERS Channel and SSID You must specify a common radio channel and SSID (Service Set ID) to be used by the router and all of its wireless clients. Be sure you configure all of its clients to the same values. Parameter SSID SSID Broadcast Wireless Mode Channel Description This is the Service Set ID. The SSID must be the same on the router and all of its wireless clients. Select to enable/disable the brocasting of SSID. Enable this function for easy connection for the clients. Disable this function for increased security. The Router supports 11n, 11g, and 11b wireless networks. SMC recommend using Mixed 802.11n, 802.11g and 802.11b to provide compatibility with 11n, 11g and 11b wireless clients. This is the radio channel used for wireless communication. 4-33 CONFIGURING THE BARRICADE Parameter Bandwidth Extension Channel Protected Mode 802.11e/WMM QoS Description Select the bandwidth:
20 MHz: Sets the operation bandwidth as 20 MHz. when 20 MHz is selected, there would be no extension channel available. 20/40 MHz: Allows automatic detection of the operation bandwidth between 20 and 40 MHz. Choosing this mode allows you to use the extension channel. This is the optional channel for use. Setting the Bandwith to 20/40 MHz allows you to use this extension channel as the secondary channel for doubling the bandwith of your wireless network. In most situations, best performance is achieved with Protected Mode turning Off. If you are operating in an environment with heavy 802.11b traffic or interference, best performance may be achieved with Protected Mode turning On. Select to turn on/turn off the QoS function. Notes: 1. When bandwidth is set to 20 MHz, there would be no extension channel that can be selected. The extension channel is based on the main or primary channel. When the main channel is set to channel 1, channel 5 will be used as the extension channel. When the main channel is set to 9, the extension channel can be channel 5 or 13. 2. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user. 4-34 CONFIGURATION PARAMETERS Access Control Using the Access Control functionality, you can restrict access based on MAC address. Each PC has a unique identifier known as a Medium Access Control (MAC) address. With MAC filtering enabled, the computers whose MAC address you have listed in the filtering table will be able to connect (or will be denied access) to the router. Enable MAC Filtering: select to enable or disable this function. Access Rule for registered MAC address: select to allow/deny access for the registered MAC addresses. Selecting Allow means only MAC addresses registered here will be able to connect to the router. Selecting Deny means only the MAC addresses registered here will be denied access to the router. Wireless DHCP Client List: use the drop down list to quickly copy the current entry to the table. MAC Filtering Table: you can enter up to 32 stations to the table. 4-35 CONFIGURING THE BARRICADE Security To make your wireless network safe, you should turn on the security function. Allowed Client Type:
No WEP, No WPA - this means no security mechanism will be used on your wireless network. WEP only - this menas only WEP will be used for your wireless communication. WPA only - this means only WPA will be used for the wireless network. 4-36 CONFIGURATION PARAMETERS WEP Parameter WEP Mode Key Entry Method Key Provisioning Description Select 64 bit, or 128 bit. Select Hex, or ASCII. Select Static, or Dynamic. If you select Static, you will need to configure the Static WEP Key Setting section. If you choose Dynamic, then 802.1X authentication should be enabled. To automatically generate encryption keys using the passphrase function, when Key Entry Method is set to Hex, enter a string into the passphrase field, then click Generate. Select the Default Key ID from the drop-down menu and click SAVE SETTINGS. To manually configure the encryption key, enter five hexadecimal pairs of digits for each 64-bit key, or enter 13 pairs for the single 128-bit key. Note: A hexadecimal digit is a number or letter in the range 0-9 or A-F. The passphrase can consist of up to 32 alphanumeric characters. 4-37 CONFIGURING THE BARRICADE WPA Wi-Fi Protected Access (WPA) combines temporal key integrity protocol
(TKIP) and 802.1X mechanisms. It provides dynamic key encryption and 802.1X authentication service. The router supports both WPA and WPA2. Parameter WPA mode Cypher suite Authentication Pre-shared key type Pre-shared Key Group Key Re_Keying 4-38 Description Select WPA, WPA2 or mixed mode. Select the encryption cypher for use. Choose 802.1X or Pre-shared Key to use as the authentication method. 802.1X: for the enterprise network with a RADIUS server. Pre-shared key: for the SOHO network environment without an authentication server. Select the key type to be used in the Pre-shared Key. Enter the key string here. Define the time period for re-obtain the key. CONFIGURATION PARAMETERS 802.1X If 802.1X is used in your network, then you should enable this function for the router. Parameter 802.1X authentication Session Idle Timeout Re-Authentication Period Quiet Period Server Type RADIUS Server Parameters Description Choose to enable or disable this function. Defines a maximum period of time for which the connection is maintained during inactivity. Defines a maximum period of time for which the authentication server will dynamically re-assign a session key to a connected client. Defines a maximum period of time for which the router will wait between failed authentications. Select RADIUS. Server IP Server Port Enter the authentication server IP address. Enter the port number. 4-39 CONFIGURING THE BARRICADE Parameter Secret Key NAS-ID Description The secret key shared between the authentication server and its clients. Defines the request identifier of the Network Access Server. WPS (Wi-Fi Protected Setup) The Barricade was implemented with the ease-of-use Wi-Fi Protected Setup (WPS). WPS makes a secure wireless network much easier to achieve by using a PIN number and the Push Button Control (PBC). Enable or disable WPS features: select to enable or disable. Generate New PIN: click this button to create a new PIN. Restore Default PIN: click this button to restore the PIN. 4-40 CONFIGURATION PARAMETERS PIN Enter the PIN of the client device and click Start PIN. Then start WPS on the client device from it's wireless utility or WPS application within 2 minutes. Take the following steps for easy network security settings. 1. Power on your client device supporting WPS PIN code method. 2. Start WPS PIN process on client device. For instructions on how to do this refer to the client devices user manual. 3. Enter the PIN code of client device. Note: The PIN code is generally printed on the bottom of the unit or displayed in the utility. 4. Click the Start PIN button on the screen. 4-41 CONFIGURING THE BARRICADE PBC (Push Button Configuration) To achieve successful WPS connection, you can use one of the following ways:
(1) push and hold the WPS button on this router for 4 seconds or
(2) click the Start PBC button on this screen. Now click the WPS button on the client device which you are connecting. Make sure the client device is powered on. Note: This connection procedure must be done within 2 minutes after pressing the WPS button on the router. 4-42 CONFIGURATION PARAMETERS Manual For client devices without the WPS function, you should manually configure the client device with the settings on this screen. 4-43 CONFIGURING THE BARRICADE NAT Network Address Translation (NAT) allows multiple users to access the Internet sharing one public IP. Enable or disable NAT module function: select to enable or disable this function. 4-44 CONFIGURATION PARAMETERS Address Mapping Allows one or more public IP addresses to be shared by multiple internal users. This also hides the internal network for increased privacy and security. Enter the Public IP address you wish to share into the Global IP field. Enter a range of internal IPs that will share the global IP into the from field. 4-45 CONFIGURING THE BARRICADE Virtual Server If you configure the Barricade as a virtual server, remote users accessing services such as web or FTP at your local site via public IP addresses can be automatically redirected to local servers configured with private IP addresses. In other words, depending on the requested service (TCP/UDP port number), the Barricade redirects the external service request to the appropriate server (located at another internal IP address). For example, if you set Type/Public Port to TCP/80 (HTTP or web) and the Private IP/Port to 192.168.2.2/80, then all HTTP requests from outside users will be transferred to 192.168.2.2 on port 80. Therefore, by just entering the IP address provided by the ISP, Internet users can access the service they need at the local address to which you redirect them. The more common TCP service ports include:
HTTP: 80, FTP: 21, Telnet: 23, and POP3: 110. A list of ports is maintained at the following link:
http://www.iana.org/assignments/port-numbers. 4-46 CONFIGURATION PARAMETERS Special Application Some applications require multiple connections, such as Internet gaming, video-conferencing, and Internet telephony. These applications may not work when Network Address Translation (NAT) is enabled. If you need to run applications that require multiple connections, use these screens to specify the additional public ports to be opened for each application. Use the Popular applications drop down menu to quickly copy the entry to the table. 4-47 CONFIGURING THE BARRICADE NAT Mapping Table This screen displays the current NAPT (Network Address Port Translation) address mappings. Click Refresh to update the table. 4-48 CONFIGURATION PARAMETERS Routing These screens define routing related parameters, including static routes and RIP (Routing Information Protocol) parameters. Static Route Parameter Index Network Address Subnet Mask Gateway Description Check the box of the route you wish to delete or modify. Enter the IP address of the remote computer for which to set a static route. Enter the subnet mask of the remote network for which to set a static route. Enter the WAN IP address of the gateway to the remote network. Click Add to add a new static route to the list, or check the box of an already entered route and click Modify. Clicking Delete will remove an entry from the list. 4-49 CONFIGURING THE BARRICADE RIP Parameter General RIP Parameters RIP mode Auto summary Description Globally enables or disables RIP. If Auto summary is disabled, then RIP packets will include sub-network information from all sub-networks connected to the router. If enabled, this sub-network information will be summarized to one piece of information covering all sub-networks. Table of current Interface RIP parameter Interface Operation Mode Version 4-50 The WAN interface to be configured. Disable: RIP disabled on this interface. Enable: RIP enabled on this interface. Silent: Listens for route broadcasts and updates its route table. It does not participate in sending route broadcasts. Sets the RIP (Routing Information Protocol) version to use on this interface. Parameter Poison Reverse Authentication Required CONFIGURATION PARAMETERS Description A method for preventing loops that would cause endless retransmission of data traffic. None: No authentication. Password: A password authentication key is included in the packet. If this does not match what is expected, the packet will be discarded. This method provides very little security as it is possible to learn the authentication key by watching RIP packets. MD5: An algorithm that is used to verify data integrity through the creation of a 128-bit message digest from data input (which may be a message of any length) that is claimed to be as unique to that specific data as a fingerprint is to a specific individual. Authentication Code Password or MD5 Authentication key. RIP sends routing-update messages at regular intervals and when the network topology changes. When a router receives a routing update that includes changes to an entry, it updates its routing table to reflect the new route. RIP routers maintain only the best route to a destination. After updating its routing table, the router immediately begins transmitting routing updates to inform other network routers of the change. 4-51 CONFIGURING THE BARRICADE Routing Table Parameter Description Flags Indicates the route status:
C = Direct connection on the same subnet. S = Static route. R = RIP (Routing Information Protocol) assigned route. I = ICMP (Internet Control Message Protocol) Redirect route. Destination IP address. The subnetwork associated with the destination. This is a template that identifies the address bits in the destination address used for routing to specific subnets. Each bit that corresponds to a 1 is part of the subnet mask number; each bit that corresponds to 0 is part of the host number. The IP address of the router at the next hop to which frames are forwarded. The local interface through which the next hop of this route is reached. When a router receives a routing update that contains a new or changed destination network entry, the router adds 1 to the metric value indicated in the update and enters the network in the routing table. Network Address Netmask Gateway Interface Metric 4-52 CONFIGURATION PARAMETERS Firewall The Barricade Routers firewall inspects packets at the application layer, maintains TCP and UDP session information including time-outs and the number of active sessions, and provides the ability to detect and prevent certain types of network attacks. Network attacks that deny access to a network device are called Denial-of-Service (DoS) attacks. DoS attacks are aimed at devices and networks with a connection to the Internet. Their goal is not to steal information, but to disable a device or network so users no longer have access to network resources. The Barricade protects against the following DoS attacks: IP Spoofing, Land Attack, Ping of Death, IP with zero length, Smurf Attack, UDP port loopback, Snork Attack, TCP null scan, and TCP SYN flooding.
(For details see page 4-60.) The firewall does not significantly affect system performance, so we advise enabling the function to protect your network. Select Enable and click the SAVE SETTINGS button. 4-53 CONFIGURING THE BARRICADE Access Control Access Control allows users to define the outgoing traffic permitted or not-permitted through the WAN interface. The default is to permit all outgoing traffic. Parameter Enable Filtering Function Normal Filtering Table Description Enable or Disable Access control function. Displays descriptive list of filtering rules defined. 4-54 CONFIGURATION PARAMETERS To create a new access control rule:
1. Click Add PC on the Access Control screen. The Access Control Add PC screen will appear. 2. Define the appropriate rule settings for client PC services. 3. Click OK and then click SAVE SETTINGS to save your settings. 4-55 CONFIGURING THE BARRICADE MAC Filter The MAC Filter allows you to define what client PC's can access the Internet. When filtering function is enabled only the MAC addresses defined in the MAC Filtering table will have access to the Internet. All other client devices will be denied access. You can enter up to 32 MAC addresses in this table. MAC Address Control: select enable or disable. MAC Filtering Table: enter the MAC address in the space provided. 4-56 CONFIGURATION PARAMETERS URL Blocking The Barricade allows the user to block access to web sites by entering either a full URL address or just a keyword. This feature can be used to protect children from accessing violent or pornographic web sites. You can define up to 30 sites here. 4-57 CONFIGURING THE BARRICADE Schedule Rule You may filter Internet access for local clients based on rules. Each access control rule may be activated at a scheduled time. Define the schedule on the Schedule Rule screen, and apply the rule on the Access Control screen. 4-58 CONFIGURATION PARAMETERS Follow these steps to add a schedule rule:
1. Click Add Schedule Rule on the Schedule Rule screen. The Edit Schedule Rule screen will appear. 2. Define the appropriate settings for a schedule rule. 3. Click OK and then click SAVE SETTINGS to save your settings. 4-59 CONFIGURING THE BARRICADE Intrusion Detection Intrusion Detection Feature Stateful Packet Inspection (SPI) and Anti-DoS firewall protection (Default:
Enabled) The Intrusion Detection Feature of the Barricade Router limits access for incoming traffic at the WAN port. When the SPI feature is turned on, all incoming packets will be blocked except for those types marked in the Stateful Packet Inspection section. RIP Defect (Default: Enabled) If an RIP request packet is not acknowledged to by the router, it will stay in the input queue and not be released. Accumulated packets could cause the input queue to fill, causing severe problems for all protocols. Enabling this feature prevents the packets from accumulating. Discard Ping to WAN (Default: Disabled) Prevent a ping on the Barricades WAN port from being routed to the network. Scroll down to view more information. 4-60 CONFIGURATION PARAMETERS 4-61 CONFIGURING THE BARRICADE Stateful Packet Inspection This is called a stateful packet inspection because it examines the contents of the packet to determine the state of the communications; i.e., it ensures that the stated destination computer has previously requested the current communication. This is a way of ensuring that all communications are initiated by the recipient computer and are taking place only with sources that are known and trusted from previous interactions. In addition to being more rigorous in their inspection of packets, stateful inspection firewalls also close off ports until connection to the specific port is requested. When particular types of traffic are checked, only the particular type of traffic initiated from the internal LAN will be allowed. For example, if the user only checks FTP Service in the Stateful Packet Inspection section, all incoming traffic will be blocked except for FTP connections initiated from the local LAN. Stateful Packet Inspection allows you to select different application types that are using dynamic port numbers. If you wish to use the Stateful Packet Inspection (SPI) to block packets, click on the Yes radio button in the Enable SPI and Anti-DoS firewall protection field and then check the inspection type that you need, such as Packet Fragmentation, TCP Connection, UDP Session, FTP Service, H.323 Service, or TFTP Service. When hackers attempt to enter your network, we can alert you by e-mail Enter your email address. Specify your SMTP and POP3 servers, user name, and password. 4-62 CONFIGURATION PARAMETERS Connection Policy Enter the appropriate values for TCP/UDP sessions as described in the following table. Parameter Fragmentation half-open wait Defaults 10 sec TCP SYN wait TCP FIN wait TCP connection idle timeout UDP session idle timeout H.323 data channel idle timeout 30 sec 5 sec 3600 seconds
(1 hour) 30 sec 180 sec Description Configures the number of seconds that a packet state structure remains active. When the timeout value expires, the router drops the unassembled packet, freeing that structure for use by another packet. Defines how long the software will wait for a TCP session to synchronize before dropping the session. Specifies how long a TCP session will be maintained after the firewall detects a FIN packet. The length of time for which a TCP session will be managed if there is no activity. The length of time for which a UDP session will be managed if there is no activity. The length of time for which an H.323 session will be managed if there is no activity. 4-63 CONFIGURING THE BARRICADE DoS Criteria and Port Scan Criteria Set up DoS and port scan criteria in the spaces provided (as shown below). Parameter Total incomplete TCP/UDP sessions HIGH Total incomplete TCP/UDP sessions LOW Incomplete TCP/UDP sessions
(per min) HIGH Incomplete TCP/UDP sessions
(per min) LOW Maximum incomplete TCP/UDP sessions number from same host Incomplete TCP/UDP sessions detect sensitive time period Maximum half-open fragmentation packet number from same host Half-open fragmentation detect sensitive time period Flooding cracker block time Defaults Description 300 sessions Defines the rate of new unestablished sessions that will cause the software to start deleting half-open sessions. Defines the rate of new unestablished sessions that will cause the software to stop deleting half-
open sessions. Maximum number of allowed incomplete TCP/UDP sessions per minute. 250 sessions 250 sessions 200 sessions Minimum number of allowed incomplete TCP/UDP sessions per minute. 10 300 msec 30 10000 msec 300 second Maximum number of incomplete TCP/UDP sessions from the same host. Length of time before an incomplete TCP/UDP session is detected as incomplete. Maximum number of half-open fragmentation packets from the same host. Length of time before a half-open fragmentation session is detected as half-open. Length of time from detecting a flood attack to blocking the attack. Note: The firewall does not significantly affect system performance, so we advise enabling the prevention features to protect your network. 4-64 CONFIGURATION PARAMETERS DMZ If you have a client PC that cannot run an Internet application properly from behind the firewall, you can open the client up to unrestricted two-way Internet access. Enter the IP address of a DMZ (Demilitarized Zone) host on this screen. Adding a client to the DMZ may expose your local network to a variety of security risks, so only use this option as a last resort. 4-65 CONFIGURING THE BARRICADE SNMP Use the SNMP configuration screen to display and modify parameters for the Simple Network Management Protocol (SNMP). Select the SNMP Operation mode from the drop down menu. 4-66 CONFIGURATION PARAMETERS Community A computer attached to the network, called a Network Management Station (NMS), can be used to access this information. Access rights to the agent are controlled by community strings. To communicate with the Barricade, the NMS must first submit a valid community string for authentication. Parameter Community Access Valid Description A community name authorized for management access. Management access is restricted to Read Only (Read) or Read/Write (Write). Enables/disables the entry. Note: Up to five community names may be entered. 4-67 CONFIGURING THE BARRICADE Trap Specify the IP address of the NMS to notify when a significant event is detected by the agent. When a trap condition occurs, the SNMP agent sends an SNMP trap message to any NMS specified as a trap receiver. Parameter IP Address Community Version Description Traps are sent to this address when errors or specific events occur on the network. A community string (password) specified for trap management. Enter a word, something other than public or private, to prevent unauthorized individuals from accessing information on your system. Sets the trap status to disabled, or enabled with V1 or V2c. The v2c protocol was proposed in late 1995 and includes enhancements to v1 that are universally accepted. These include a get-bulk command to reduce network management traffic when retrieving a sequence of MIB variables, and a more elaborate set of error codes for improved reporting to a Network Management Station. 4-68 CONFIGURATION PARAMETERS UPnP The Universal Plug and Play architecture offers pervasive peer-to-peer network connectivity of PCs of all form factors, intelligent appliances, and wireless devices. UPnP enables seamless proximity network in addition to control and data transfer among networked devices in the office, home and everywhere within your network. UPnP allows the device to automatically:
join a network obtain an IP address convey its capabilities and learn about the presence and capabilities of other devices. Check Enable to activate this function. 4-69 CONFIGURING THE BARRICADE ADSL ADSL (Asymmetric Digital Subscriber Line) is designed to deliver more bandwidth downstream (from the central office to the customer site) than upstream. This section is used to configure the ADSL operation type and shows the ADSL status. ADSL Parameters This screen is designed for the engineer to test the ADSL loop condition. Therefore, it is advised that users should not change the settings here at all. Parameter Operation Mode Automatic T1.413 Issue 2 Description G.992.1 (G.DMT) G.992.2 (G.Lite) G.992.3 ADSl2 G.992.5 ADSL2+
4-70 CONFIGURATION PARAMETERS ADSL Status The Status screen displays information on connection line status, data rate, operation data and defect indication, and statistics. Parameter Status Line Status Data Rate Upstream Downstream Description Shows the current status of the ADSL line connection. Maximum upstream data rate. Maximum downstream data rate. Operation Data/Defect Indication Noise Margin Output Power Attenuation Maximum upstream and downstream noise margin. Maximum fluctuation in the output power. Maximum reduction in the strength of the upstream and downstream signal. 4-71 CONFIGURING THE BARRICADE Parameter Fast Path FEC Correction Interleaved Path FEC Correction Fast Path CRC Error Interleaved Path CRC Error Loss of Signal Defect Loss of Frame Defect Loss of Power Defect Fast Path HEC Error Interleaved Path HEC Error Statistics Received Cells Transmitted Cells Description There are two latency paths that may be used: fast and interleaved. For either path, a forward error correction (FEC) scheme is employed to ensure higher data integrity. For maximum noise immunity, an interleaver may be used to supplement FEC. An interleaver is basically a buffer used to introduce a delay, allowing for additional error correction techniques to handle noise. Interleaving slows the data flow and may not be optimal for real-time signals such as video transmission. The number of Fast Path Cyclic Redundancy Check errors. The number of Interleaved Path Cyclic Redundancy Check errors. Momentary signal discontinuities. Failures due to loss of frames. Failures due to loss of power. Fast Path Header Error Concealment errors. Interleaved Path Header Error Concealment errors. Number of cells received. Number of cells transmitted. 4-72 CONFIGURATION PARAMETERS DDNS Dynamic Domain Name Service (DDNS) provides users on the Internet with a method to tie their domain name to a computer or server. DDNS allows your domain name to follow your IP address automatically by having your DNS records changed when your IP address changes. This DNS feature is powered by DynDNS.org or NO-IP.com or TZO.com. With a DDNS connection you can host your own web site, email server, FTP site, and more at your own location even if you have a dynamic IP address. 4-73 CONFIGURING THE BARRICADE Tools Use the Tools menu to ping, trace route, backup the current configuration, restore a previously saved configuration, update firmware, and reset the Barricade. Ping Utility This tool allows you to test your network connection. You can specify a domain name or a valid IP address of the remote host for ping test. Enter the address in the Destination address field, then click Execute. The result will show in the Test Result area. 4-74 CONFIGURATION PARAMETERS Trace Route Utility Traceroute is a TCP/IP utility which allows the user to determine the route packets take to reach a particular host. Enter the information in the IP Address or Domain Name field, and click the Traceroute button. 4-75 CONFIGURING THE BARRICADE Configuration Tools Choose a function and click Next. Backup Router Configuration: this allows you to save the Barricades configuration to a file. Restore from saved Configuration file: this function is used to restore the previously saved backup configuration file. Restore router to Factory Defaults: this resets the Barricade back to the original default settings. 4-76 CONFIGURATION PARAMETERS Firmware Upgrade Use this screen to update the firmware or user interface to the latest versions. 1. Download the upgrade file from the SMC web site first, and save it to your hard drive. 2. Then click Browse... to look for the downloaded file. Click BEGIN UPGRADE. Check the Status screen Information section to confirm that the upgrade process was successful. 4-77 CONFIGURING THE BARRICADE Reset Click REBOOT ROUTER to reset the Barricade. The reset will be complete when the power LED stops blinking. If you perform a reset from this screen, the configurations will not be changed back to the factory default settings. Note: If you use the Reset button on the back panel, the Barricade performs a power reset. If the button is pressed for over 10 seconds, all the LEDs will illuminate and the factory default settings will be restored. 4-78 CONFIGURATION PARAMETERS Status The Status screen displays WAN/LAN connection status, firmware, and hardware version numbers, illegal attempts to access your network, as well as information on DHCP clients connected to your network. The security log may be saved to a file by clicking Save and choosing a location. Scroll down to view more information on the Status screen. 4-79 CONFIGURING THE BARRICADE 4-80 CONFIGURATION PARAMETERS The following items are included on the Status screen:
Parameter INTERNET Release Renew GATEWAY Description Displays WAN connection type and status. Click on this button to disconnect from the WAN. Click on this button to establish a connection to the WAN. Displays system IP settings, as well as DHCP Server and Firewall status. ATM PVC Disabled Connect INFORMATION Displays the number of attached clients, the firmware versions, the physical MAC address for each media interface and for the Barricade, as well as the hardware version and serial number. Displays ATM connection type and status. The ATM connection is disabled. Click on this button to establish a connection to the ATM connection. Displays attempts to access your network. Click on this button to save the security log file. Click on this button to delete the access log. Click on this button to refresh the screen. Save Clear Refresh Security Log DHCP Client Log Displays information on DHCP clients on your network. 4-81 CONFIGURING THE BARRICADE Finding the MAC address of a Network Card Windows 2000/XP Click Start/Programs/Command Prompt. Type ipconfig /all and press ENTER. The MAC address is listed as the Physical Address. Macintosh Click System Preferences/Network. The MAC address is listed as the Ethernet Address on the TCP/IP tab. Linux Run the command /sbin/ifconfig. The MAC address is the value after the word HWaddr. 4-82 APPENDIX A TROUBLESHOOTING This section describes common problems you may encounter and possible solutions to them. The Barricade can be easily monitored through panel indicators to identify problems. Troubleshooting Chart Symptom LED Indicators Power LED is Off Action Check connections between the Barricade, the external power supply, and the wall outlet. If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or external power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses, or surges at the power outlet. If you still cannot isolate the problem, then the external power supply may be defective. In this case, contact Technical Support for assistance. A-1 TROUBLESHOOTING Troubleshooting Chart Symptom LED Indicators Link LED is Off Action Verify that the Barricade and attached device are powered on. Be sure the cable is plugged into both the Barricade and the corresponding device. Verify that the proper cable type is used and that its length does not exceed the specified limits. Be sure that the network interface on the attached device is configured for the proper communication speed and duplex mode. Check the adapter on the attached device and cable connections for possible defects. Replace any defective adapter or cable if necessary. Network Connection Problems Cannot ping the Barricade from the attached LAN Verify that the IP addresses are properly configured. For most applications, you should use the Barricades DHCP function to dynamically assign IP addresses to hosts on the attached LAN. However, if you manually configure IP addresses on the LAN, verify that the same network address (network component of the IP address) and subnet mask are used for both the Barricade and any attached LAN devices. Be sure the device you want to ping (or from which you are pinging) has been configured for TCP/IP. A-2 TROUBLESHOOTING Troubleshooting Chart Action Symptom Management Problems Cannot connect using the web browser Forgot or lost the password Be sure to have configured the Barricade with a valid IP address, subnet mask, and default gateway. Check that you have a valid network connection to the Barricade and that the port you are using has not been disabled. Check the network cabling between the management station and the Barricade. Press the Reset button on the rear panel (holding it down for at least 10 seconds) to restore the factory defaults. A-3 APPENDIX B CABLES Ethernet Cable Caution: DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards. Specifications Cable Types and Specifications Cable 10BASE-T 100BASE-TX Cat. 5 100-ohm UTP Type Cat. 3, 4, 5 100-ohm UTP Max. Length 100 m (328 ft) 100 m (328 ft) Connector RJ-45 RJ-45 Wiring Conventions For Ethernet connections, a twisted-pair cable must have two pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be red and the other, red with white stripes. Also, an RJ-45 connector must be attached to both ends of the cable. B-1 CABLES Each wire pair must be attached to the RJ-45 connectors in a specific orientation. The following figure illustrates how the pins on an Ethernet RJ-45 connector are numbered. Be sure to hold the connectors in the same orientation when attaching the wires to the pins. Figure B-1. RJ-45 Ethernet Connector Pin Numbers RJ-45 Port Connection Use the straight-through CAT-5 Ethernet cable provided in the package to connect the Barricade to your PC. When connecting to other network devices such as an Ethernet switch, use the cable type shown in the following table. Attached Device Port Type MDI-X MDI Connecting Cable Type Straight-through Crossover B-2 ETHERNET CABLE Pin Assignments With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6 for receiving data. RJ-45 Pin Assignments Pin Number 1 2 3 6 1: The + and - signs represent the polarity of the wires Assignment1 Tx+
Tx-
Rx+
Rx-
that make up each wire pair. Straight-Through Wiring If the port on the attached device has internal crossover wiring (MDI-X), then use straight-through cable. Straight-Through Cable Pin Assignments End 1 1 (Tx+) 2 (Tx-) 3 (Rx+) 6 (Rx-) End 2 1 (Tx+) 2 (Tx-) 3 (Rx+) 6 (Rx-) B-3 CABLES Crossover Wiring If the port on the attached device has straight-through wiring (MDI), use crossover cable. Crossover Cable Pin Assignments End 1 1 (Tx+) 2 (Tx-) 3 (Rx+) 6 (Rx-) End 2 3 (Rx+) 6 (Rx-) 1 (Tx+) 2 (Tx-) B-4 ADSL CABLE ADSL Cable Use standard telephone cable to connect the RJ-11 telephone wall outlet to the RJ-11 ADSL port on the ADSL Router. Caution: Do not plug a phone jack connector into an RJ-45 port. Specifications Cable Types and Specifications Cable ADSL Line Type Standard Telephone Cable Connector RJ-11 Wiring Conventions For ADSL connections, a cable requires one pair of wires. Each wire is identified by different colors. For example, one wire might be red and the other, red with white stripes. Also, an RJ-11 connector must be attached to both ends of the cable. Each wire pair must be attached to the RJ-11 connectors in a specific orientation. The following figure illustrates how the pins on the RJ-11 connector are numbered. Be sure to hold the connectors in the same orientation when attaching the wires to the pins. Figure B-2. RJ-11 Connector Pin Numbers B-5 CABLES e t i h W
e u B l l e u B
e t i h W e g n a r O
e t i h W e t i h W
e g n a r O e t i h W
e u B l l e u B
e t i h W k c a B l d e R n e e r G w o l l e Y R1 T1 T2 R1 T1 R2 T2 R1 T1 R2 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 6x2 Jack 6x4 Jack 6x4 Jack T = Tip R = Ring Pin 1 2 3 4 5 6 Signal Name Not used Line 2 Tip Line 1 Ring Line 1 Tip Line 2 Ring Not used Figure B-3. RJ-11 Pinouts Wire Color Black or White/Orange Red or Blue/White Green or White/Blue Yellow or Orange/White B-6 APPENDIX C SPECIFICATIONS Physical Characteristics Ports Four 10/100Mbps RJ-45 ports One ADSL port (RJ-11) ADSL Features Supports DMT line modulation Supports Annex A Full-Rate ADSL: up to 8 Mbps downstream, up to 1 Mbps upstream (G.992.1 &T1.413, Issue 2) and ADSL2 (G.992.3) and ADSl2+ (G.992.5) Supports G.Lite ADSL: up to 1.5 Mbps downstream, up to 512 Kbps upstream Dying GASP support ATM Features RFC1483 Encapsulation (IP, Bridging and encapsulated routing) PPP over ATM (LLC &VC multiplexing) (RFC2364) Classical IP (RFC1577) Traffic shaping (UBR, CBR) OAM F4/F5 support PPP over Ethernet Client Management Features Firmware upgrade via web based management web based management (configuration) Power Indicators Event and History logging Network Ping Traceroute C-1 SPECIFICATIONS Security Features Password protected configuration access User authentication (PAP/CHAP) with PPP Firewall NAT NAPT VPN pass through (IPSec-ESP Tunnel mode,L2TP, PPTP) LAN Features IEEE 802.1D (self-learning transparent Bridging) DHCP Server DNS Proxy Static Routing, RIPv1 and RIP Temperature: IEC 68-2-14 0 to 40 degrees C (Standard Operating)
-40 to 70 degree C (Non-operation) Humidity 10% to 90% (Non-condensing) Vibration: IEC 68-2-36, IEC 68-2-6 Shock: IEC 68-2-29 Drop: IEC 68-2-32 Dimensions: 143mm(L) x 94mm(D) x 32mm(H) Weight: 500 g Input Power: 15 V 0.8A IEEE Standards IEEE 802.3, 802.3u, 802.11g, 802.1D , 802.11 n draft ITU G.dmt, ITU G.Handshake, ITU T.413 issue 2 - ADSL full rate Standards Conformance Electromagnetic Compatibility CE, ETSI, R&TTE, FCC part 15 class B & FCC part 68 Safety EN 60950-1 C-2 Wireless Frequency Band 802.11b/g/n Radio: 2.4 GHz USA - FCC 2412~2462 MHz (Ch1~Ch11) Europe - ETSI 2412~2472 MHz (Ch1~Ch13) France 2457~2472 MHz (Ch10~Ch13) Modulation Technology: DSSS, OFDM Operating Channels:
IEEE 802.11b compliant:
11 channels (US, Canada) 13 channels (ETSI) 4 channels (France) IEEE 802.11g compliant:
11 channels (US, Canada) 13 channels (Europe) IEEE draft 802.11n 20MHz compliant:
11 channels (US, Canada) 13 channels (Europe) IEEE draft 802.11n 40MHz compliant:
7 channels (US, Canada) 9 channels (Europe) Signal Type: DSSS/OFDM Operating Frequency: 2.412 - 2.462GHz SPECIFICATIONS C-3 SMC7904WBRA-N SMCWBR11-G
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2007-11-16 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2007-11-16
|
||||
1 | Applicant's complete, legal business name |
Arcadyan Technology Corporation
|
||||
1 | FCC Registration Number (FRN) |
0009258708
|
||||
1 | Physical Address |
No.8, Sec.2, Guangfu Rd.
|
||||
1 |
Hsinchu, N/A 30071
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@curtis-straus.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
RAX
|
||||
1 | Equipment Product Code |
7904WBRA-N
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S******** L********
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
s******@arcadyan.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Advance Data Technology Corporation (Hsin Chu)
|
||||
1 | Name |
E******** L****
|
||||
1 | Physical Address |
81-1 Luliaoken, 9th Lin, Wulung Tsuen Chiunglin
|
||||
1 |
Hsinchu, 307
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
e******@adt.com.tw
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Advance Data Technology Corporation
|
||||
1 | Name |
E******** L****
|
||||
1 | Physical Address |
81-1 Luliaoken, 9th Lin, Wulung Tsuen Chiunglin
|
||||
1 |
Hsinchu, 307
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
e******@adt.com.tw
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Draft 11n Wireless 4-Port Annex A ADSL2/2 Router | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is the maximum combined conducted output power. Device is a draft 802.11n Router operating in a 2x3 Spatial Multiplexing MIMO configuration as described in this filing. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch
|
||||
1 | Name |
R****** C****
|
||||
1 | Telephone Number |
886-2********
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
r******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | MO | 2412.00000000 | 2462.00000000 | 0.1760000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC