EP3011 Quick Installation Guide 1. Product Overview 1.1 Interface
(1) Interfaces
(2) LEDs Interface & Button Description SW POWER WAN RST LAN Power On/Off 24VDC, 1A 1 RJ45, WAN 10/100/1000 auto-sensing, auto-MDX, 24V 0.5A PoE Long press over 10 seconds to restore factory settings 2 RJ45, LAN 10/100 auto-sensing, auto-MDX Description No. Name 1 Power 2 WLAN 3 LTE (if connect to LTE ODU) Power On No Power Supply Status Steady On OFF Steady On Wi-Fi enabled Wi-Fi disabled OFF Blinking Wi-Fi is starting LTE is connected Steady On LTE is disconnected OFF Blinking LTE is starting 1 No. Name 4 Signal (if connect to LTE ODU) Status Steady On OFF Blinking Description The more the lights on, the stronger the signal No signal or weak signal Only the first LED on the left is blinking The two LEDs on the left are blinking Three LEDs blinking Attaching to the LTE network Attached successfully Scanning the LTE network 2. Specifications Item Description Standard IEEE 802.11b/g/n/ac(WA) or 802.11bgn(WN) Channel Bandwidth 20MHz, 40MHz or 20MHz, 40MHz, 80MHz Frequency TXRX MIMO Peak Rate Modulate Sensitivity Antenna Type Antenna Gain 2.4GHz, 5GHz or 2.4G only 2T2R 22 802.11b: 11Mbps 802.11g: 54Mbps 802.11n: 300Mbps 802.11ac: 866Mbps DSSS/CCK, OFDM
-64 dBm@65Mbit/s, typical for 802.11n/ac
-65 dBm@54Mbit/s, typical for 802.11g
-76 dBm@11Mbit/s, typical for 802.11b Internal omni-antenna 5dBi 3. Installation Guide 3.1 Support Materials Before installation, prepare the following support materials:
Item Ethernet cable Ground wire Outdoor Shield CAT5E Shorter than 330 feet 16mm yellow-green wire Description 3.2 Installation CAUTION:
NO OTHER DEVICES ARE ALLOWED TO BE CONNECT WITH IDUs WAN PORT EXCEPT BAICELLS OUD PRODUCTS (EG7035E/L and EG7010A/C) Operations in the 5.15-5.25GHz band are restricted to indoor usage only. 4. Configuration Guide 4.1 Log in The EP3011 manages, configures, and maintains the device by web management page. The steps to log in are as follows:
1. In the address column of browser, type in http://192.168.150.1, then press Enter, login in page is shown in Figure 4-1. Figure 4-1 Login Page 2. Enter the user name and password, click "LOGIN". After password authentication, you can log on to the web management page. The default user name and password is admin. For security, it is recommended that you open the firewall, and keep your login password, WLAN FTP passwords and password well. 4.2 View Status In the overview area, you can view the device information and LTE status, such as Product name, Software version, PLMN, IMSI, RSRP, RSRQ, CINR, SINR, Tx Power, Cell ID, PCI, and so on, as shown in Figure 4-2. Figure 4-2 View Status 4.3 Basic Configuration 4.3.1 LTE Setting To set the LTE Network, perform the following steps:
1. Choose LTE. 2. In the LTE Setting area, configure the LTE network. 4.3.2 Set Connection Method To set the LTE network connection method, perform the following steps:
1. Choose LTE>connection Method, enter the setting connection method page, as shown in Figure 4-3. Figure 4-3 Set Connection Method 2. In the connection Method area, set the connection method 3. There are two methods to connect the LTE network, it is needed to choose a method between Auto and Manual, if you want to auto connect to the LET network you should choose the Auto, otherwise you should choose Manual. 4. Click SAVE & APPLY. Regulatory Compliance FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. ISEDC Compliance This device complies with Innovation, Science, and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Innovation, Science et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.