All-in-One Telehealth Video Terminal Quick Start Guide 1 Appearance and Interface The terminal can be placed on horizontal desktop or installed on the TV and wall with bracket. Desktop Installation Place the terminal on the desktop, keep the desktop steady and pay attention to the anti-slip. Install on TV with Bracket (optional) Install on Wall with Bracket No. 1 Interface DC 12V 2 3 4 USB 3.0 USB 3.0 HDMI IN 5 HDMI OUT1 6 7 8 9 HDMI OUT2 Touch LAN PC 10 11 LINE IN LINE OUT Description Power interface Connect to U-disk, mouse, keyboard and other USB devices. Connect to U-disk, mouse, keyboard and other USB devices. Connect to PC or camera, support audio input. Connected to the terminal and HDTV with HDMI cable, support audio output and it will be muted automatically while use the built-in speaker. Connected to the terminal and HDTV with HDMI cable. Connect to tablet and other control device. Connect the terminal to the network with the network cable. Used as a camera and speakerphone when connect to PC. 3.5mm audio input interface 3.5mm audio output interface 2 Installation and Connection Warning Operating this equipment in a residential environment may cause radio interference. Connection The cable connections shown in the following figure contains optional configurations and for reference only. Please connect the cables according to actual needs. 3 Product Dimension PC LINE IN LINE OUT DC 12V USB 3.0 USB 3.0 HDMI IN HDMI OUT1 HDMI OUT2 Touch LAN P o w e r A d a p t e r U S B C a b l e U S B C a b l e H D M I C a b l e i A u d o C a b l e H D M I C a b l e i A u d o C a b l e H D M I C a b l e N e t w o r k C a b l e N e t w o r k C a b l e 0
. 5 3 1 2
. 9 9 12:34 12:34 min max min max JOHN DOE JOHN DOE MainStr eet, number, Cit y Name(Country) 123-456-789 www.yourdomain.com yourname@ domain.com 114.7 Power Plug MIC PC Computer Mixer HDTV Speaker HDTV Tablet Switch Power Connect 4 Troubleshooting Connect the power cord to the supplied power adapter, and then connect the terminal to the power outlet with the power adaptor. No Response Network Connect Connect LAN with the network cable;
Or, connect the LAN via Wi-Fi. Audio Input Audio input via the built-in microphone;
Or, connect a microphone to the USB interface with the USB Please try to reboot APS100. Not Enough Storage Space 1) System storage space is low, please make sure you have 250MB of free space and reboot APS100. 2) The total storage of APS100 is 8G, when storage space is not enough, please try to clear some data to release the storage. cable. Wi-Fi Network Cannot Access the Internet Connect a mixer to the LINE IN interface with the 3.5mm cable. Please contact with Caregility IT department to check whether the Audio Output Audio output via the built-in speaker;
device has the permission to access the Internet. Or, connect TV to the HDMI OUT1 interface with the HDMI cable;
Or, connect a speaker to the LINE OUT interface with the 3.5mm 5 Cleaning Guide cable. Image Input Image input via the built-in camera. Connect camera to the HDMI IN interface with the HDMI cable;
Or, connect a PC or other devices to the HDMI IN interface with the HDMI cable. Image Output Connect TV and other display devices to the HDMI OUT1 interface with the HDMI cable to output the main image. Connect TV and other display devices to the HDMI OUT2 interface with the HDMI cable to output the second image. For the Whole Camera Cleaning The user can take a rag, dip in Ethyl Alcohol Absolute to wipe the appearance gently. For the Speaker Cover Cleaning Fabric model: CY-B51-1, the main component is polyester fiber, the surface of the fabric is treated with waterproof technology, and the backside viscose technology is added. Cleaning Precautions Wipe with soft brush at room temperature. No long-term alkali resistance, please choose a neutral volatile cleaning agent.
*Although we have done and passed the corrosion resistance test of chemical reagents, for the long-term cleaning and maintenance of APS100, it is recommended to use Ethyl Alcohol Absolute for cleaning. 6 Important Safety Instructions 8 ISED Compliance Statements Parts of the ME EQUIPMENT that are not serviced or maintained This device contains licence-exempt transmitter(s)/receiver(s) that while in use with the patient. comply with Innovation, Science and Economic Development Instructions provided indicating not to position ME EQUIPMENT Canadas licence-exempt RSS(s). Operation is subject to the to make it difficult to operate the disconnection device. following two conditions: (1 )This device may not cause Warning statement that addressed the HAZARDS the ME interference.(2)This device must accept any interference, including EQUIPMENT. interference that may cause undesired operation of the device. Unplug the power cable to power off. Lmetteur/rcepteur exempt de licence contenu dans le prsent Do not leave the equipment in an uncontrolled environment appareil est conforme aux CNR dInnovation, Sciences et where the storage temperature is below -20 C (-4 F) or above 60 Dveloppement conomique Canada applicables aux appareils C (140 F) and the relative humidity is below 30% or above 75%
radio exempts de licence. Lexploitation est autorise aux deux it may damage the equipment. conditions suivantes :(1)Lappareil ne doit pas produire de 7 FCC Compliance Statements brouillage; (2)Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This device complies with Part 15 of the FCC Rules. Operation is This equipment complies with IC RSS-102 radiation exposure limits subject to the following two conditions: (1) this device may not set forth for an uncontrolled environment. This equipment should cause harmful interference, and (2) this device must accept any be installed and operated with minimum distance 20cm between interference received, including interference that the radiator and your body. may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection Cet quipement est conforme aux limites d'exposition aux radiations IC CNR-102 tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 20cm entre le radiateur et votre corps. against harmful interference in a residential installation. This a) The device for operation in the band 5150-5250 MHz is only for equipment generates, uses and can radiate radio frequency energy indoor use to reduce the potential for harmful interference to and, if not installed and used in accordance with the instructions, co-channel mobile satellite systems;
may cause harmful interference to radio communications. b) The maximum antenna gain permitted for devices in the band However, there is no guarantee that interference will not occur in a 5725-5825 MHz shall comply with the e.i.r.p. limits specified for particular installation. point-to-point and non point-to-point operation as If this equipment does cause harmful interference to radio or appropriate. television reception, which can be determined by turning the c) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont equipment off and on, the user is encouraged to try to correct the rservs uniquement pour uneutilisation lintrieur afin de interference by one or more of the following measures:
rduire les risques de brouillage prjudiciable aux systmes de satellites mobiles utilisant les mmes canaux;
Le gain maximal dantenne permis (pour les dispositifs utilisant la bande 5725-5825 MHz). doit se conformer la limite de p.i.r.e. spcifie pour lexploitation point point et non point point, selon le cas.
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. 9 EMC Guidance 10 Product Specifications Warning: Dont use near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. Warning: Use of this equipment adjacent to or stacked with other You should now recycle your waste electrical goods and in doing so equipment should be avoided because it could result in improper help the environment. This symbol means an electrical product operation. If such use is necessary, this equipment and the other should not be disposed of with normal household waste. Please equipment should be observed to verify that they are operating ensure it is taken to a suitable facility for disposal when finished with. normally. Warning: Use of accessories, transducers, and cables other than those specified or provided by the manufacturer of this equipment Hereby, Caregility declare that the radio equipment type APS100 is compliance with Directive 2014/53/EU. could result in increased electromagnetic emissions or decreased The equipment has passed IEC certification entries, and electromagnetic immunity of this equipment and result in CB mark is allowed to be added legally. improper operation. Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 in (30 cm) to any part of the equipment, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result. Compliance Group 1 Guidance and Manufacturers Declaration Electromagnetic Emissions Emissions test RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations/
flicker emissions IEC 61000-3-3 Complies Class B Class A Users are recommended to read this manual before using this device. Operating Environment:
Temperature: 0C ~ 40C Relative Humidity: 10% ~ 80% R.H. Atmospheric Pressure: 80kPa ~ 106kPa Storage Environment:
Temperature: -20C ~ 60C Relative Humidity: 30% ~ 75% R.H Atmospheric Pressure: 70kPa ~106kPa;
Product Information:
Manufacturer Name: Caregility Manufacturer Address: 81 Corbett Way Eatontown, NJ 07724, United States of America Model Name: APS100 Adapter: It is part of ME equipment Device Input: 12V 3A Power Input: AC100-240V~50/60Hz 1.2A Serial No.: APS100YYYYMMDDXXXX (e.g. APS100202210140001) Infrared Light: Wave crest 850nm, optical power 550mW (max.) Intended Use: The APS100 is intended to provide two-way video and audio between the remote clinician and the patient bedside. 079.79.1101XXX_V1.0