JY clke Sco EM658 SPECIFICATION 1.Button Key One key only 2.Features 2.1 Indoor and Outdoor Temperature Display 2.2 Monitor up to 4 remotes 2.3 C/F selectable, Defaultis F 2.4 Power up auto learn house code, 4 remotes must be same. 2.5 Low battery indication with low battery icon 2.6 Indoor and Outdoor Temperature (no Humidity function) 2.7 Losing signal indication
@ If there is no reading received, it shows the last reading
@ Last reading will being to flash after about 60 minutes of no reception to remind user there is a problems.(flash every 5 seconds)
@ Display will return to normal once a new reading is received 2.8 Button key function
@ At normal mode, push (less than 2 seconds) the button to change indoor or outdoor temperature, change from indoor to CH1, CH2, CH3, CH4 . Push once to advance a step.
@ At indoor temperature display mode, hold the button for 2 seconds to select CIF.
@ At outdoor temperature display mode, hold the button for 2 seconds to reset the house code of channels. 2.9 Default Value: Degree F 3. Specification 3.1 Temperature Resolution: 1C( because Deltech dont need decimal) 3.2 Temperature range: 0C to +55C(+32F to +132) :
Out of temperature range shows Lo or Hi 3.3 Accuracy for temperature: +/-1.5C(+/-2.7F) 3.7 Sampling rate: Indoor thermometer 2 times per minute. OUTDOOR UNIT SPECIFICATION 1.Button key:
<1> Set(To set house code and device code)
<2> 'C/*F (Change display unit when pressed) 2.Feature:
2.1 With LCD display with temperature 2.2 4 remote channels selection 2.3 Antenna icon indicating the signal transmission, antenna icon display at least for 1 second. 2.4 C/F selectable, Default is F 2.5 Low Battery Indication with Low Battery Icon 2.6 30 house code and 4 devices code to be selected using SET key.(Holding 2 seconds to set house code and device code) 3. Specification:
3.1 Temperature range(with the extension wire probe sensor):-20C to +70 C;Default is F.Out of temperature range shows Lo or Hi. Transmitter operation range:-20C to +70C (Operation range base on good battery condition) 3.2 Accuracy for temperature:+/-1.5C (in transmitter operation range) 3.3 Resolution:0.1 degree for temperature 3.4 Transmission range: 100 feet in open area 3.5 Sampling rate: two times per minute for temperature 3.6 Tx cycle: about 1 minute RECEIVED 1 7 ger 2002 casonse ats XY 3]
fA & > BAA RA G CASON ELECTRONICS HOLDINGS CO., LTD. UNIT 13-16, 17/F., TOWER A, REGENT CENTRE, 63 WO YI HOP ROAD, KWAI CHUNG, N.T. H.K. FAX: (852) 24891184 URL wwrvee onelec com E-MAIL: info@cason.com.hk
: Www.Cason-!
C) Reorient or relocate the receiving antenna. LI Increase the separation between the equipment and receiver. i) Connect the equipment Into an outlet on a circuit different from that to which the receiver is connected. 1 Consult the dealer or an experienced radio / TV technician for help.