PSS-29ZBS(R) / PSM-29ZBS(R) Power Switch Series Introduction The Power Switch series include the following models:
PSS-29ZBS: ZigBee Power Switch PSS-29ZBSR: ZigBee Power Switch with Router function PSM-29ZBS: ZigBee Power Switch with Meter PSM-29ZBSR: ZigBee Power Switch with Meter and Router function The Power Switches are capable of receiving wireless signals from the coordinator in the Zigbee network to toggle On/Off of appliances that are attached to it. The Power Switch utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission. Models with Meter functions (PSM-29ZBS / PSM-29ZBSR) have the extra feature of keeping tracks of energy consumption with built-in power meter and transmit the data to coordinator regularly. Models with router function (PSS-29ZBSR / PSM-29ZBSR) also serve as a router in the ZigBee network. After being included in the ZigBee network, it allows other ZigBee device to join the network through the Power Switch. Model No. PSS-29ZBS PSS-29ZBSR PSM-29ZBS PSM-29ZBSR Parts Identification 1. Function Button aka LED indicator Meter No No Yes Yes No Yes No Yes ZigBee Router The Function Button also doubles as the LED Indicator. The function button is used to control the Power Switch. The LED indicator is used to indicate Power Switch status. LED Indication:
The LED indicator lights up in the following conditions:
- On:
The Power Switch is turned on.
- Off:
The Power Switch is turned off.
- Flashes twice:
The Power Switch has successfully joined a ZigBee network.
- Flashes 5 times The Power Switch has successfully bound with a controller
- Flashes every 20 minutes The Power Switch has lost connection to its current ZigBee network
(PSS-29ZBS and PSM-29ZBS only) Function Button Usage:
- Press the button to toggle on/off the Power Switch
- Press and hold the button for 10 seconds then release to reset the Power Switch.
- Press and hold the button for 3 seconds then release to bind with a controller ZigBee Network Setup
ZZiiggBBeeee DDeevviiccee GGuuiiddeelliinnee 1 ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and are coordinated for data exchange and signal transmission.
JJooiinniinngg tthhee ZZiiggBBeeee NNeettwwoorrkk As a ZigBee device, the Power Switch needs to join a ZigBee network to receive commands and transmit energy consumption information. Follow the steps bellow to join the Power Switch into a ZigBee network. 1. Plug in the Power Switch into a power outlet. 2. Press and hold the function button for 10 seconds as the Power Switch resets and starts searching for existing ZigBee network. Please make sure the permit-to-join feature on the router or coordinator of your ZigBee network is enabled. 3. If the Power Switch successfully joins a ZigBee network, the LED Indicator will flash twice to confirm. 4. After joining the ZigBee network, the Power Switch will be registered in the network automatically. Please check the Zigbee network coordinator, system control panel or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful. 5. If registration and joining to the network is unsuccessful, please check your ZigBee network coordinator, system control panel or CIE setting to ensure the permit-to-join function is available, and then use the Factory Reset function below to join the ZigBee network.
BBiinnddiinngg wwiitthh CCoonnttrroolllleerr After joining the ZigBee network, the Power Switch can bind itself with a controller device which can be used to turn on/off the Power Switch. To bind the Power Switch and the device:
1. Press and hold the Function Button for 3 seconds, then release the button. The Power Switch will send binding request to the coordinator. 2. Refer to your controller manual to send binding request for the device within 16 seconds. 3. If binding is successful, the Power Switch LED indicator will flash 5 times to confirm. You can now use the controller to adjust power output level for the Power Switch. 4. If binding is unsuccessful, please retry the binding process.
FFaaccttoorryy RReesseett If you want to remove the Power Switch from current network and join a new network, you need to use the Factory Reset function to clear the Power Switch from its stored setting and information first before it can join another network. To perform Factory Reset:
1. Press and hold the switch button for 10 seconds, release the button until the LED Indicator flash once. 2. The Power Switch has been reset to factory default setting with all its previous network information removed. It will now actively search for available ZigBee network again and join the network automatically. 3. If the Power Switch successfully joins a ZigBee network, the LED Indicator will flash twice to indicate.
ZZiiggBBeeee RRoouutteerr DDeevviiccee CCaappaacciittyy ((PPSSSS--2299ZZBBSSRR // PPSSMM--2299ZZBBSSRR OOnnllyy)) The Power Switch models with Router function allow other ZigBee devices to join the ZigBee Network through the Router. The Power Switch Router has maximum capacity of 40 devices/routers; the Power Switch Meter Router has maximum capacity of 10/routers. Model No. Maximum ZigBee Device
+ Router Capacity PSS-29ZBSR PSM-29ZBSR 40 10 Operation
IInnssttaallllaattiioonn
Plug the Power Switch into a power outlet.
Plug the appliance into the socket of the Power Switch. The appliance must be in ON status.
IMPORTANT NOTE: The Power Switch does not have a backup battery and will be powered down when AC power fails. DO NOT use the Power Switch as router for your security sensor or alarm control devices such as Door Contact, PIR Sensoretc., otherwise the sensors will lose connection to ZigBee network if the Power Switch is disconnected from AC power. Plan the installation locations of these security sensors without using the Power Switch and only use a router with backup battery for them. The router function of the Power Switch should ONLY be used to provide signal range extension for other Power Switches/Dimmer.
AApppplliiaannccee CCoonnttrrooll
After the Power Switch has successfully joined a ZigBee network, the coordinator can remotely turn on/off the Power Switch to control the appliance 2
You can also press the button on the Power Switch to toggle its on/off status
If you have bound a controller with the Power Switch, you can also use the controller to turn on/off the Power Switch.
If the Power Switch is removed from power outlet, after replugging the Power Switch, its previous on/off status will be restored within 1 minute.
EEnneerrggyy CCoonnssuummppttiioonn MMoonniittoorr ((PPSSMM--2299ZZBBSS // PPSSMM--2299ZZBBSSRR OOnnllyy))
Power Switch models with built-in meter will transmit a signal with its power consumption data every 10 minutes to the ZigBee network coordinator.
Whenever the Power Switch energy output changes by +/- 2W, it will automatically transmit a signal with power consumption data to the ZigBee network coordinator for update.
The Power Switch transmits a signal with power data to coordinator whenever accumulated power usage increases by 0.1kW/hr.
If the Power Switch power output is below 20W, the power measurement error may become greater and the data may be inaccurate.
To clear the Power Switch of its accumulated power consumption data, follow steps below:
1. 2. 3. Unplug the Power Switch from power outlet. Press and hold the function button and plug in the Power Switch again when holding down the button. Keep holding the button and release after 3 seconds. The accumulated power consumption data will be cleared.
MMaaxxiimmuumm OOppeerraattiioonn LLooaadd
For 120V: the maximum operation load is 15A Resistive or 1/2hp or Tungsten lamp load: 5A
If the Power Switch is overheating, It will cut off power automatically as a safety measure. The Power Switch must be unplugged and replugged after cut off to resume normal operation. Appendix (For developers only)
CClluusstteerr IIDD Device ID: On Off Output :0x0002 / Mains Power Outlet :0x0009 Endpoint:0x0A Server Side Basic (0x0000) Identify(0x0003) Groups(0x0004) Scenes(0x0005) On/Off(0x0006) Mandatory Optional Metering(0x0702)(PSM-29ZBS/PSM-29ZBSR Only)
AAttttrriibbuuttee ooff BBaassiicc CClluusstteerr IInnffoorrmmaattiioonn Identifier Name Type Range 0x0000 ZCLVersion 0x0001 ApplicationVersion 0x0003 HWVersion 0x0004 ManufacturerName 0x0005 0x0006 0x0007 ModelIdentifier DateCode PowerSource Unsigned 8-bit integer Unsigned 8-bit integer Unsigned 8-bit integer Character String Character String Character String 8-bit 0x0010 LocationDescription 0x0011 PhysicalEnvironment Character String 8-bit 0x00 0xff 0x00 0xff 0x00 0xff 0 32 bytes 0 32 bytes 0 16 bytes 0x00 0xff 0 32 bytes 0x00 0xff 3 Access Read only Read only Read only Read only Read only Read only Read only Read /
Write Read /
Write Default 0x01 0x00 0 Climax Technology
(Model Version) 0x00 Client Side None None Mandatory
/ Optional M O O O O O M O O 0x0012 DeviceEnabled Boolean 0x00 0x0 1 Read /
Write 0x01 M
AAttttrriibbuuttee ooff IIddeennttiiffyy CClluusstteerr IInnffoorrmmaattiioonn Identifier 0x0000 Identifier 0x0000 Type Name Range IdentifyTime Unsigned 16-bit integer Access Read /
Write
AAttttrriibbuutteess ooff tthhee GGrroouuppss cclluusstteerr IInnffoorrmmaattiioonn Access Read only
AAttttrriibbuutteess ooff tthhee SScceenneess cclluusstteerr IInnffoorrmmaattiioonn Range x0000000 NameSupport 8-bit bitmap 0x00 0xffff Name Type Default 0x0000 Default
-
Identifier 0x0000 0x0001 Name NameSupport CurrentScene 0x0002 CurrentGroup Type 8-bit bitmap Unsigned 8-bit integer Unsigned 16-bit integer Boolean Range x0000000 0x00 0xff 0x0000 0xfff7 Access Read only Read only Read only Read only Read only Default 0x00 0x00 0x00 0x00
-
0x0003 0x0004 SceneValid NameSupport 0x00 0x01 x0000000
AAttttrriibbuuttee ooff OOnn//OOffff CClluusstteerr IInnffoorrmmaattiioonn 8-bit bitmap Mandatory
/ Optional M Mandatory
/ Optional M Mandatory
/ Optional M M M M M Mandatory
/ Optional Identifier 0x0000 Name OnOff Type Range Access Read only Default 0x00 M
AAttttrriibbuutteess ooff tthhee MMeetteerriinngg cclluusstteerr IInnffoorrmmaattiioonn ((RReeaaddiinngg IInnffoorrmmaattiioonn 0x00 0x01 Boolean AAttttrriibbuuttee SSeett)) ((PPSSMM--2299ZZBBSS // PPSSMM--2299ZZBBSSRR OOnnllyy)) Identifier Name Type Range Access 0x00 CurrentSummation Delivered Unsigned 48-bit Integer 0x000000000000 to 0xFFFFFFFFFFFF Read Only Default Mandatory
/ Optional M
AAttttrriibbuutteess ooff tthhee MMeetteerriinngg cclluusstteerr IInnffoorrmmaattiioonn ((FFoorrmmaattttiinngg AAttttrriibbuuttee SSeett)) ((PPSSMM--2299ZZBBSS // PPSSMM--2299ZZBBSSRR OOnnllyy)) Range Name Identifier 0x00 0x01 0x02 0x03 0x04 0x06 UnitofMeasure Multiplier Divisor SummationFormating DemandFormating MeteringDeviceType Type 8-bit Enumeration Unsigned 24-bit Integer Unsigned 24-bit Integer 8-bit BitMap 8-bit BitMap 8-bit BitMap Access Default Mandatory
/ Optional 0x00 to 0xFF Read Only 0x00 0x000000 0xFFFFFF 0x000000 to to 0xFFFFFF 0x00 to 0xFF 0x00 to 0xFF 0x00 to 0xFF Read Only 1 Read Only 10000 Read Only Read Only Read Only 0xF9 0x93 0x00 M O O M O M
AAttttrriibbuutteess ooff tthhee MMeetteerriinngg cclluusstteerr IInnffoorrmmaattiioonn ((HHiissttoorriiccaall AAttttrriibbuuttee SSeett))
((PPSSMM--2299ZZBBSS // PPSSMM--2299ZZBBSSRR OOnnllyy)) Identifier Name Type Range Access Default Mandatory
/ Optional Read Only 0x00 O 0x00 InstantaneousDemand Signed 24-bit Integer
-8,388,607 to 8,388,607 4 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 5