submitted | available | document details (if available) | source link |
---|---|---|---|
January 11 2020 | January 11 2020 | HT-A9 英文说明书 2019.8.19 带wifi pengzo Acrobat Distiller 11.0 (Windows) |
various | User manual | Users Manual | 530.64 KiB | January 11 2020 |
Thermal Imaging Camera Instruction Manual Dongguan Xintai Instrument Co.,Ltd. Add: Building F, No. 22 Yuhua Street, Hongye Industrial Zone, Tangxia Town, Dongguan City, Guangdong Province Postcode:523710 Tel:+86-769-82612006 Fax:+86-769-82612005 Website:www.hytechcn.com.cn www.xintest.com.cn www.xintest.en.alibaba.com Email:kevin@xintest.com.cn User Manual Version 1.0. September 122019. HT-A8 HT-A9 Contents Preface Limited Warranty and Limited Responsibility Safety Instruction Preliminary Acquaintance with Infrared Thermal Imager Overview Cleaning of the Products Lens Maintenance Charging of the Battery and Description Performance Index Product Description 1. Instruction to Structure 2. Display Description 3. Key Description Initial Operation Introduction to the Menu 1.Image Overlapping Submenu 1.1. Description of Image Overlapping 1.2. Application of Image Overlapping 2. Introduction to Image Sub-menu 2.1. View Image 2.2. Delete Images
3. Introduction to Color Palette Sub-menu 3.1. Color Palette Description 3.2. Application of Color Palette 4. Introduction to Emissivity Sub-menu 4.1. Emissivity Description 4.2. Emissivity Setting 4.3. The Emissivity Value of Common Materials 5. Introduction to Setting Sub-menu 5.1. Auto Shutdown Setting 5.2. Intensity Settings 5.3. Language Settings 5.4. Unit Setting 5.5. Time Format Setting 5.6. Time Setting 5.7. Enable/disable of the Highest and Lowest Temperature Cursor 5.8. Wireless WIFI on and off Troubleshooting After-sale Service of the Product
www.xintest.com.cn www.xintest.com.cn Preface Respected users:
How are you! Thank you for purchasing our instrument. In order to use it in a better manner, we remind you to read the instruction for use carefully before use and keep it properly so as to look up in the future use. Limited warranty and limited responsibility Xintai Instruments and Apparatus Co., Ltd guarantees that the product enjoys warranty service of one year from the purchase date. But the warranty is not applicable to fuse and disposable battery or the damage caused by improper operation, accidents, negligence, misuse, remodeling, pollution and abnormal condition of the operation environment. The distributor has no right to provide any warranty in the name of Xintai Instruments and Apparatus Co., Ltd. Xintai Instruments and Apparatus Co., Ltd authorizes the retail dealers to provide new products or unused products to final customers but does not authorize them to provide guarantee with wider scope or different contents. Only the products that are purchased through distributors authorized by Xintai Instruments and Apparatus Co., Ltd or products that the purchaser paid according to proper international price can enjoy the warranty support of our company. When the product bought in a country is sent to another country for repair, Xintai Instruments and Apparatus Co., Ltd reserves the right to charge the import fees for the parts and components to be repaired or replaced from the purchasers. When warranty service is repaired, please contact the service center authorized by Xintai Instruments and Apparatus Co., Ltd to obtain the authorization information for return. Then post the product together with problem description to the service center with postage and insurance expenses prepaid. Our company will not undertake any responsibility for any damage occurred during the process of transportation. The product will be posted to the purchaser after repair with the transportation expenses paid by the purchasers. If the product failure is verified by negligence, misuse, pollution, change, accidents or improper operation or handling after inspection, including the over voltage failure caused by use without following the rated value stipulated by the product or daily service wear the of the parts, our company will estimate the repair expenses and carry out repair after obtaining the consent of the purchasers. The product will be posted back to the purchaser after repair with the transportation expenses paid by the purchasers. The guarantee is the only compensation that users can be obtained and does not include other express or implied guarantees. Xintai Instruments and Apparatus Co., Ltd will not undertake any responsibility for any special, indirect, accidental or subsequent damage or loss, including any data loss caused by any reasons or inference. Because some countries or states do not allow implied warranties and incidental or consequential damages.Restrictions, so the above limitation of liability and regulations may not apply to every buyer. The users shall make promise that they familiarize with the application field and occasi on. The purchase indicates that the users are deemed to know the suitability for the products. www.xintest.com.cn 1 2 www.xintest.com.cn Safety Instruction Warning Please ensure that you have read and understood the safety precautions described in the following text before using the product so that you can operate it correctly. The safety precautions described in the following text guides you to operate the product and its accessories correctly and safely to avoid damage and loss to you,other people and the device. Considerations Please observe the following guide in order not to damage the product:
Dont assemble or dismantle the product without permission. The product is a type of super precise equipment. Dont try to dismantle, assemble or remodel any part of the product. Repair of the product should be made by technical personnel designated by Xintai Company. Avoid damage to probe of the product Note: dont put the product close to strong heat source directly (such as electric iron). Otherwise, it may damage the probe of the product. Product hum When the product works, there is light sound of clicking every several seconds. This is normal phenomenon that the lens captures images. The warning describes the acts that may cause harm to users. Please observe the following operation in order to avoid electric shock or personal injury. Warning: Dont aim the laser pointer at human or animal's eyes. The laser given out by the laser pointer may harm the vision. If the product case is damaged, dont use it continuously. Please contact the local distributors or agents of Xintai under such condition. During the process of use, if the product is found with smoke, spark and the burnt smell, please stop using at once. In case of such condition, the product power supply should be powered off first.After the smoke and peculiar smell disappears completely, please contact the local distributors or agents of Xintai. Dont remodel the adapter and the data line. Otherwise, such remodeling may cause short circuit or fire. www.xintest.com.cn 3 4 www.xintest.com.cn Dont weld the battery without permission. Do not touch the electric wire with wet hands. Such operation may damage the battery and result in leakage and explosion of the battery. Avoid that the battery is impacted (such as collusion and falling, etc). Such condition may damage the battery case or result in that the battery leaks or explode. Please pull off the adapter on the power socket when charging is not made. The adapter may get overheated if it is connected with power supply for a long time. This may cause overheating, deformation and fire. Please ensure that the plug of the adapter is inserted into the specified power socket. The adapter plug may be different due to the regions. Please make confirmation whether the specification of the adapter is consist with the specification of electric appliances in your region. Otherwise, this may cause overheating of the equipment, electric shock, fire, chemical leakage inside the battery, explosion and other serious consequences. When the plug of the adapter or wire is damaged, stop using immediately. Dont change the battery unless the plug of the charger is inserted into the socket completely. It is possible to cause electric shock when touching the electric wire with wet hands. When pulling out the electric wire, hold the electric wire head rightly to pull out the wire. Dont pull off the electric wire directly. Otherwise, the electric wire may be broken, causing electric shock and fire. Forbid dip the product into water caught in rain. If the case contact with any liquid, please wipe it dry immediately. If water or other liquid enters the inside of the instrument, please power off the power supply at once. Continuous use may result in product damage. Clean the dust on the adapter plug and the data line. When it is exposed to dusty and dump environment for a long time, the dirt surrounding the electric equipment will accumulate moisture. This may cause short circuit and fire. Please use the original adapter of the company to charge the product. The use of non-original power supply accessories may cause equipment overheating, electric shot, fire, and leakage of chemicals inside the battery,explosion and other serious consequences. Dont use abradant, isopropanol or solvent to clean the enclosure of the device. Such operation may cause the product case to be damaged. www.xintest.com.cn 5 6 www.xintest.com.cn The product temperature may increase after a long time of charging. You may feel scorching heat when the hands touch the sensors. Problem caused by water condensation Dont bring the instrument into low temperature environment from high tempera-ture environment in a short time or from low temperature environment to high temperature environment. This may result in that the inside of the instrument and appearance produce water condensation. In such condition, the instrument should be placed into portable box or plastic bag. Before use, make it restore to the environmental temperature and take it out to use. If the product has water condensation inside, please power it off immediately.Otherwise, the instrument may be damaged. Operation is not allowed unless the water condensation disappears. Avoid that the product is impacted (such as collision and falling, etc). Such operation may cause the product to be damaged. Please avoid such operation. Long-time storage and regular charging. The product should be placed at a cool and dry environment if it not used for a long time. If the product installed with battery is stored for a long time, charging should be made regularly. Otherwise, the battery will run out and the service life will be shortened. Preliminary Acquaintance with Infrared Thermal Imager For a long time, infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries. The application field includes electric power, metallurgy, petro-chemistry, machinery,coal, traffic, fire control and national defense, etc. It can not only carries out real-time detection at high voltage, high current and high speed operation to perform real-time detection for production and instrument but also need not power off the power supply, stop the machine or stop the production to find the potential problems and prevent occurrence of malfunction. The non contact modern detection technology is safe, reliable and quick. It is a type of technical revolution compared with traditional contact detection method. The infrared thermal imaging technology is widely used in the following fields:
Power equipment, transmission, transformer line inspection;
Hidden fire source search in fire protection;
Personnel search and rescue in the fire, and fire command;
Analyze the location and heat loss of leak points in heat pipes and heating equipment;
Determining the location of the heating fault of the operating train;
Security department night monitoring. www.xintest.com.cn 7 8 www.xintest.com.cn Overview This product is an infrared camera that integrates surface temperature measurement and real-time thermal image. The traditional inferred thermometer needs to measure every component one by one while it is not necessary for infrared imaging camera, thus saving time. The potential problems may be displayed on color display screen clearly. Moreover, the central point measurement cursor is used to locate quickly and accurately to measure the temperature of the target object. In order to increase the differentiation, the product is provided with a visible light camera. The thermal images and visible images are stored in the device and can be read through USB or stored in a computer to generate a report or for print. With small volume, the product is easy to operate and has strong function. it is the ideal selection for electric power, electronic manufacturing, Industrial inspection and other fields. The following major functions increase the products accuracy and usability:
The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface. The highest temperature and lowest temperature cursor may guide the users to the areas with highest and lowest temperature of the thermal images. The selectable color palette. Cleaning of the Products Please use damp cloth or weak soap to clean the enclosure of the device. Dont use abradant, isopropanol or solvent to clean. The lens and screen should be cleaned with use of cleaning agents for professional optical glasses. Lens Maintenance Prevent damage of the infrared lens Clean the infrared lens carefully. The lens is provided with refined anti-reflection coating. Dont clean with force to prevent damage of the anti-reflection coating.The selectable color palette. Use a cleaning solution for lens maintenance, such as alcohol-based commercial lens cleaners, alcohol, and a lint-free cloth or paper towel. Compressed air tanks can be used to remove loose particles. Clean the lens:
The compressed air tank or dry nitrogen ion gun (if applicable) may be used to blow the loose particles on the lens surface. Dip the lint free cloth in alcohol. Squeeze the excessive alcohol in the cloth or apply the lint free cloth on dry cloth lightly. Wipe the lens surface by making circular motion. Then discard the cloth. If it is necessary to repeat above step, please use new cloth to dip with the cleaning solution to wipe. www.xintest.com.cn 9 10 www.xintest.com.cn Charging of the Battery and Description Performance Index Use USB data line to charge:
The product has built-in chargeable 26650 lithium batteries. When the battery level is low, the top right of the screen will display
.Please charge in time through Micro USB interface. Pull off the USB line after fully charging. Note: When the battery is completely empty, there will be an abnormality. It is recommended to use the battery when it is sufficient. To make the lithium ion battery can play the perfect performance:
Dont place the battery on the charger exceeding 24 hours. The thermal imaging device should be charged for two hours at least every three months so as to extend the battery service life to the greatest extent. Dont try to charge the battery in extremely cold environment. Model HT-A8 HT-A9 Display screen 3.5-inch full-view TFT display 3.5-inch full-view TFT display Infrared image resolution 220160 320240 Visible image resolution 300000pixel 300000pixel 640480 5642 LCD resolution Field angle Thermal sensitivity 640480 3527
Frame rate of thermal images 9Hz Focus mode Wavelength coverage Fixed 8-14um Emissivity Color palette Temperature measurement range Measurement accuracy Adjustable from 0.01 to 1.00 Rainbow, iron oxide red, cold color, black & white, white & black
www.xintest.com.cn 11 12 www.xintest.com.cn Storage capacity Built-in 8G (Actually available 6.6G) File format USB Power supply JPG Micro USB 2.0 Built-in chargeable 26650 battery Detachable Working time 3-4 hours Setting command Unitlanguagedatetimeinformation Language EnglishChineseItalianGerman Automatic power-off time Selectable: 5 minutes/20 minutes/
not power off automatically Product size Product weight 256mm97.2mm128.9mm 588g Work temperature 0to 45 Storage temperature
-20 to 60 Relative humidity
< 85%RH Product Description 1. Instruction to Structure Display screen Keypad Handheld www.xintest.com.cn 13 14 www.xintest.com.cn 1 Micro Please open the cap in use Visible light camera Infrared imaging sensor Image capture key Battery 2. Display Description WiFi Current emissivity Central point temperature The highest temperature cursor Temperature cursor at central point Battery power The lowest temperature cursor Color code Time Maximum value/minimum value of field temperature Color code: used to mark the color corresponding to the relative temperature from low to high in the field of version. The central point temperature cursor: used to indicate the central position in the screen area. The cursor color displays white. The temperature value is displayed top left corner of the screen. The highest temperature cursor: used to indicate the highest temperature position in the screen area. It will move with the movement of the highest temperature. The cursor displays red. The temperature value is displayed at bottom left corner of the screen. 2 www.xintest.com.cn 15 16 www.xintest.com.cn The lowest temperature cursor: used to indicate the lowest temperature position in the screen area. It will move with the movement of the lowest temperature. The cursor displays red. The temperature value is displayed at the central position of the screen. 3. Key description Menu key/On/off key Selection key/Entry key Navigation key: Up, down, left and right Initial Operation Product boot/shutdown Press and hold the / MENU button for more than 3 seconds to turn the Thermal Imaging on or off. LCD screen display After turning on the power, the screen shows the thermal imaging status. Note:
Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures. Witching between infrared thermal image and visible image press or key to switch the degree of fusion between inferred thermal images and visible images (the degree of fusion is 0%, 25%, 50%, 75% and 100%). Image capture Press the image capture key. When the capture is successful, the screen will display save photo? prompt. Select "Yes" or "No" to delete the image, press the " " " " button to Switch the selection,then press the SELECT/ENTER button to confirm.Yes, you can press the capture button again if you are sure to save the image. www.xintest.com.cn 17 18 www.xintest.com.cn The function to hide highest/lowest temperature column at the screen bottom under the operation after normal start up, press key and the screen bottom will display highest/lowest temperature column. Press can also hide it. Image output The saved images through capture may be checked and output by connecting with a computer through Micro USB. Read images Open the USB protective cover as shown in . Use USB line to connect the USB port and then computer to read the images or save it into computers.images or save it into computers. 2 The supported operating system through verification includes:
winxp, win7, win 8, win10, Apple system. It is suggested to use the attached USB line or USB line with higher quality. Note:
When connecting with a computer, pull off the data line after selecting pop out device safely to avoid causing file system damage and other problems. If unable to save and other problems occur, you may find the hard disc in the computer and fix it. Introduction to the Menu Press the left of /MENU key and the menu bar appears. They are Image overlapping, Image, Color palette, Emissivity and Setting submenus. 1.Image Overlapping Submenu 1.1. Description of Image Overlapping Image overlapping makes it easier for users to understand the infrared images by using aligned visible images and infrared images. The use of image overlapping can capture the visible image of every infrared image so as to display the temperature distribution in the target region correctly and share with other people more effectively. 1.2. Application of Image Overlapping Press the / MENU button to enter the main menu, and select
(Image registration) in the main menu. Press the SELECT/ENTER button to enter the image overlap adjustment mode.Press the navigation keys (up, down, left and right buttons) to perform the visible image shift operation. Press the SELECT/ENTER button to exit the image blending mode
(Note: If there is no operation for more than 6 seconds, the image blending mode will be automatically exited). www.xintest.com.cn 19 20 www.xintest.com.cn 2. Introduction to Image Sub-menu 2.1. View Image Press the / MENU button to enter the main menu, and select
(image) in the main menu.
As shown in the figure, Then press key to enter image list. Press or key in navigation to select the image. Then press SELECT/ENTER key to view image. When viewing the images, press key to view the precious image, Press to view the next image. Press SELECT/ENTER key to return. Press /MENU key to exit from the menu. 2.2. Delete Images While viewing the image, press the button, the screen will display Delete photo? Select "Yes" or "No" to delete the image, press the
" "" " button to Switch the selection, then press the SELECT/ENTER button to confirm.When the image is deleted, No Image will be displayed. Press SELECT/ENTER to return to the menu and press /MENU to exit the menu. 3. Introduction to Color Palette Sub-menu 3.1. Color Palette Description The palette can be used to change the pseudo-color display of the infrared image on the display. Some tune Swatches are better suited for specific applications and can be set up as needed. The palette is divided into: rainbow, iron red, cool, white hot, black hot, five palettes. These palettes work best with high thermal contrast and provide additional color contrast between high and low temperatures. Suitable selection of color palette displays the details of the target objective better. Rainbow, iron oxide red and cold color palettes focus on display of color. Such color palettes are very suitable for high heat contrast and are used to improve the color contrast between high temperature and low temperature. But the black &
white and white & black color palettes provide even linear color. The following is the image of the same object with selection of different color palettes. www.xintest.com.cn 21 22 www.xintest.com.cn 4. Introduction to Emissivity Sub-menu 4.1. Emissivity Description The emissivity of the product can be adjusted from 0.01 to 1.00 with the default value of 0.95. Many common objects and materials (such as timber, water, skin and textile fabric) can reflect the heat energy effectively. So it is easy to obtain relatively correct measurement value. The emissivity is usually set as 0.95 when the coarse objects that are easy to give out energy. For semi-matte objects that give out less energy, the emissivity is usually about 0.85 and the emissivity of semi-gloss objects is 0.6. The shiny objects are divided into materials with low radiation coefficient. The emissivity is usually set as 0.3 at the time of measurement. Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement. The surface emissivity will produce giant impact on surface temperature measured by the product. Understanding the surface emissivity will enable you to obtain correct temperature measurement result. Rainbow Iron oxide red Cold color White heat Black heat 3.2. Application of Color Palette
As shown in the figure, press /MENU key to enter the main menu and select (color palette) option and press key to enter the color palette list. Press and keys in navigation to select the color palette. Then press SELECT/ENTER key to select the color palette. Press to return. Press / MENU key to exit from the menu. www.xintest.com.cn 23 24 www.xintest.com.cn 4.2. Emissivity Setting The product is provided with four types of object measurement modes:
Coarse object (0.95) Semi-matte object (0.85) Semi-shiny object (0.60) Shiny object (0.30) According to the characteristics of the measured objects, users may set the emissivity value through the self-define option (please refer to the table of emissivity of common materials). The operating step is as the following:
As shown in the figure, press / MENU key to enter the main menu and select (emissivity) option and press key to enter the emissivity list. Press and keys in navigation key to select the emissivity. Then press SELECT/ENTER key to determine selection of the emissivity. Press key again to return. If you select "self-defined" emissivity, press the " SELECT/ENTER " button to enter the editing state.Press / keys to select the number to be changed, press keys to change the value. After themodification is completed, press SELECT/ENTER to confirm, then press to return. The / MENU button exits the menu.
www.xintest.com.cn 25 26 www.xintest.com.cn 4.3. The Emissivity Value of Common Materials 5. Introduction to Setting Sub-menu Substance Thermal radiation Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics 0.90~0.98 0.94 0.96 0.90 0.92~0.96 0.92~0.96 0.96~0.98 0.83 0.90~0.95 0.90~0.94 Marble 0.94 Gypsum 0.80~0.90 Mortar Brick 0.89~0.91 0.93~0.96 Substance Black cloth Human skin Foam Thermal radiation 0.98 0.98 0.75~0.80 Charcoal dust 0.96 Paint Matte paint Black rubber Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide Textile 0.80~0.95 0.97 0.94 0.85~0.95 0.90 0.70~0.94 0.81 0.78 0.78~0.82 0.90 www.xintest.com.cn 27 Press /MENU key to select the (setting) option in the main menu. Press key again to enter the setting sub-menu. Settings Auto shutdown Intensity Auto shutdown Intensity Language Language Unit
Time format Unit Time Format Set time Set time NO 5min 20min Low Medium Hight English Chinese Italian German Celsius Fahrenheit 24 hour AM/PM Year Month Day Hour Minute Second 2019 09 18 15 15 15 Spot WiFi 28 Spot WiFi Off On Off On www.xintest.com.cn 5.1. Auto Shutdown Setting After entering the "Settings" sub-menu, select " / MENU" (automatic shutdown), press navigationThe button in the button enters the auto power off setting. Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes. 5.2. Intensity Settings After selecting (brightness), press the button in the navigation key to enter the brightness setting. Can be set to low or medium or bright. 5.3. Language Settings After selecting " " (language), press the " " button in the navigation key to enter the language setting. Available in 4 languages: English, Chinese, Italian, German. 5.4. Unit Setting After selecting (unit), press the button in the navigation key to enter the temperature unit setting. Can be set to Celsius or Fahrenheit. 5.5. Time Format Setting
After you select " "(time format), press the " " key in the navigation key to enter the time format setting. Can be set to 24 hours or 12 hours. 5.6. Time Setting As shown in the figure, after selecting (set time), press in the navigation key to enter the setting time.
Press / to select year/month/day/hour/minute. After selecting, press SELECT/ENTER key to enter the edit state. Press and keys to select the figure to be changed. Press / key to change the value. After completing the change, press SELECT/ENTER to enter. After the time setting is completed, press key to return. Press / MENU exit from the menu. www.xintest.com.cn 29 30 www.xintest.com.cn 5.7. Enable/Disable of the Highest and Lowest Temperature Cursor As shown in the figure, after selecting (cold hotspot), press the button in the navigation key to enter the cold hotspot setting. 5.8. Wireless WIFI on and off As shown in the figure, after selecting (WiFi), press the button in the navigation key to enter the WIFI setting.
Press / key to select enable or disable the option. Press / key to select on or off the option. Then press SELECT/ENTER key to determine selection. Then press SELECT/ENTER key to determine selection. After the setting is completed,press key to return. Press
/ MENU key to exit from the menu. After the setting is completed,press key to return. Press
/ MENU key to exit from the menu. www.xintest.com.cn 31 32 www.xintest.com.cn After enabling WIFI, use the mobile device to search for WIFI. The hotspot name is ThermalCamera-xxxxxx (xxxxxx is the last six digits of the MAC);
access the device through the IP address 192.168.230.1. In the mobile device, you can set the color palette, blending degree, emissivity, maximum/minimum value, language conversion, and synchro-
nize to the machine. The settings on the machine can also be synchronized to the mobile device (Note: if not converted, on the mobile Refresh on the device). Click on the photo on the mobile device and the image is saved on the machine as shown below. Click Image in the mobile device to enter the image view, press the image to download the image, long press the image to save to the mobile device, click Infrared Video Stream to return to the video stream webpage, as shown below. www.xintest.com.cn 33 34 www.xintest.com.cn Troubleshooting If you encounter with any problem when using the thermal image device, please use the following table for repair.If the problems are not solved, please cut off the power supply and contact with the manufacturer. Failure phenomenon The thermal imaging device cannot start The thermal imaging device powers off automatically Failure cause The battery is not installed The power of the battery is used up The power of the battery is used up Solution Install the battery Replace with new battery or charge it Replace with new battery or charge it The time set for automatic power off is due Restart or change the time for automatic power off after restarting
(refer to 5.1) After-sale Service of the Product Respected customers:
Thank you for purchasing the product of our company. The product carries a warranty period from the date of sale. During the warranty period of the product, if installation and use is made according to the user manual at normal environment and conditions, users may enjoy free repair service by warranty voucher for faulty product caused by raw materials and manufacturing process. The warranty voucher should be kept properly by the users and will not be reissued if lost. In order to avoid problems during the use process, our company suggests that you familiarize with the user manual of the product first before the product is used. The following conditions are not within the warranty scope:
1. Unable to show the original of effective warranty voucher. 2. The product installation does not comply with product requirements and relevant specification, which causes damage;
3. The damage is caused due to that users use and store it improperly or dismantle and repair it without permission and other reasons;
4. Damage caused by natural disasters (earthquake, flood and lightning stroke) and external disasters;
5. Exceed the warranty period. Considerations:
1. If the product malfunction, repair or replacement with new or good product is made according to the condition after the product is inspected. 2. For product exceeding the warranty period, determine whether to repair or replace the part after inspection for the product is performed. Relevant expense will be charged for all types of repair and replacement of parts and components according to actual condition. 1. The product enjoys warranty service within one year from the purchase date if it is used normally and not dismantled and is confirmed by warranty personnel for product quality problem. Repair will be provided at any condition. 2. The warranty voucher should be filled at the time of purchase. It should be carried for product maintenance. Customers name Purchase date Product type Distributor Warranty record:
www.xintest.com.cn 35 36 www.xintest.com.cn FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
*RF warning for Portable device:
The device has been evaluated to meet general RF exposure requirement. The device can be used
portable exposure condition without restriction.
This product uses the FCC Data API but is not endorsed or certified by the FCC