all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.27 MiB | April 09 2014 | |||
1 | Attestation Statements | April 09 2014 | ||||||
1 | Cover Letter(s) | April 09 2014 | ||||||
1 | Cover Letter(s) | April 09 2014 | ||||||
1 | External Photos | April 09 2014 | ||||||
1 | Internal Photos | April 09 2014 | ||||||
1 | ID Label/Location Info | April 09 2014 | ||||||
1 | Operational Description | April 09 2014 | ||||||
1 | RF Exposure Info | April 09 2014 | ||||||
1 | Test Report | April 09 2014 | ||||||
1 | Test Setup Photos | April 09 2014 |
1 | User Manual | Users Manual | 2.27 MiB | April 09 2014 |
TABLE OF CONTENTS TABLE OF CONTENTS Conventions Copyright 0-vii 0-ix Product Overview Package Contents Product Overview 1-1 1-2 Key Features . 1-2 Benefits . 1-3 Technical Specification . 1-4 Wireless Specification . 1-4 Hardware Specification . 1-4 Software Specification. 1-4 1-5 Product Interface Installation System Requirements 2-1 I TABLE OF CONTENTS Installing the Device 2-2 Pre-Installation Guidelines . 2-2 Installing the Device . 2-2 Wall Mounting the Device . 2-3 Pole Mounting the Device . 2-4 Web Configuration Logging In 3-1 Best Practices . 3-2 Basic Network Settings System Status Using Save/Reload Viewing System Information Viewing Wireless Client List Viewing System Log Viewing Connection Status Viewing DHCP Client Table II 4-1 4-1 4-2 4-4 4-5 4-6 4-7 TABLE OF CONTENTS Router Setup System Setup Viewing WDS Link List Configuring WAN Settings Configuring Operation Mode Configuring IP Settings Configuring Spanning Tree Settings 4-8 4-9 4-9 4-10 4-11 4-12 4-12 Static IP. 4-12 Dynamic IP. 4-13 Point-to-Point Protocol over Ethernet (PPPoE). 4-14 Point-to-Point Tunnelling Protocol (PPTP) . 4-15 4-17 4-18 4-19 4-21 4-22 4-22 Access Point Mode. 4-22 Client Bridge Mode . 4-24 WDS Bridge Mode . 4-26 Configuring LAN Settings Configuring VPN Pass-Through Configuring Port Forwarding Configuring Demilitarized Zone Configuring Wireless Settings Configuring Wireless LAN III TABLE OF CONTENTS Configuring Wireless Security Client Router Mode . 4-28 4-30 Wired Equivalent Privacy (WEP) . 4-30 Wi-Fi Protected Access Pre-Shared Key (WPA-PSK) . 4-31 Wi-Fi Protected Access 2 Pre-Shared Key (WPA2-PSK). 4-32 Wi-Fi Protected Access Pre-Shared Key (WPA-PSK) Mixed . 4-33 Wi-Fi Protected Access (WPA) . 4-34 Wi-Fi Protected Access 2 (WPA2) . 4-35 Wi-Fi Protected Access (WPA) Mixed . 4-36 4-37 4-38 4-39 Wireless Traffic Shaping. 4-39 4-40 4-40 4-41 4-42 4-44 4-45 4-46 Configuring Administrator Account Configuring Management VLAN Configuring SNMP Configuring Backup/Restore Settings Configuring Auto Reboot Settings Configuring Firmware Upgrade Configuring Wireless MAC Filter Configuring WDS Link Settings Configuring Advanced Network Settings Management Setup IV TABLE OF CONTENTS Configuring System Time Configuring Wi-Fi Schedule 4-47 4-48 Add a Schedule Service . 4-48 Schedule Services Table. 4-49 4-50 4-51 4-52 4-53 4-54 4-55 Configuring Command Line Interface Configuring Logging Configuring Diagnostics Viewing Device Discovery Configure Denial of Service Protection Logging Out V TABLE OF CONTENTS Federal Communication Commission Interference Statement Appendix A Europe EU Declaration of Conformity WorldWide Technical Support Appendix B Appendix C A-1 B-1 C-1 VI CONVENTIONS Example:
Indicates information used to demonstrate or explain an associated concept. N/A:
Indicates that a component or a procedure is not applica-
ble to this model. Prerequisite:
Indicates a requirement that must be addressed before proceeding with the current function or procedure. Conventions The following conventions are used to give the user additional information about specific procedures or content. It is important to pay attention to these conventions as they provide informa-
tion to prevent damage to equipment or personal injury. General Conventions The following general conventions are used in this document.
CAUTION!
CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES. CAU-
TIONS APPEAR IN CAPITAL LETTERS TO EMPHASIZE THAT THE MESSAGE CONTAINS VITAL HEALTH AND SAFETY INFORMATION. WARNING!
Warning information appears before the text it references to emphasize that the content may prevent damage to the device or equipment. Important:
Indicates information that is important to know for the proper completion of a procedure, choice of an option, or completing a task. Note:
Indicates additional information that is relevant to the cur-
rent process or procedure. VII CONVENTIONS Typographical Conventions The following typographical conventions are used in this docu-
ment:
Italics Indicates book titles, directory names, file names, path names, and program/process names. Constant width Indicates computer output shown on a computer screen, includ-
ing menus, prompts, responses to input, and error messages. Constant width bold Indicates commands lines as entered on the computer. Vari-
ables contained within user input are shown in angle brackets (< >). Bold Indicates keyboard keys that are pressed by the user. VIII Copyright This user guide and its content is copyright of EnGenius Net-
works, 2014. All rights reserved. Any redistribution or reproduction in part or in whole in any form is prohibited. Do not distribute, transmit, store in any form of electronic retrieval system or commercially exploit the content without the expressed written permission of EnGenius Networks. COPYRIGHT IX Product Overview Chapter 1 PRODUCT OVERVIEW PACKAGE CONTENTS 1.1 Package Contents The EnStation package contains the following items:
EnStation PoE Injector with Power Adapter 24V PoE Injector Quick Installation Guide Mounting Screw Set Wall Mount Kit Pole Mount Strap 1-1 PRODUCT OVERVIEW PRODUCT OVERVIEW 1.2 Product Overview Thank you for choosing EnStation2. The EnStation2 is a long range, high performance IEEE 802.11b/g/n network solution that provides Access Point, Client Bridge, WDS, and Client Router functions in a single device. In addition to providing the latest wireless technology, the EnStation2 supports Power over Ethernet and Power by Adapter capabilities, which allow the device to be installed eas-
ily in nearly any indoor or outdoor location. Advanced features include power level control, traffic shaping, and Real time RSSI indication. A variety of security features help to protect your data and pri-
vacy while you are online. Security features include Wi-Fi Pro-
tected Access (WPA PSK/WPA2 PSK), 64/128/156 bit WEP Encryption, and IEEE 802.1x with RADIUS. Key Features High-speed data rates up to 300 Mbps make the EnStation2 ideally suited for handling heavy data payloads such as MPEG video streaming High output power up to 26 dBm delivers superior range and coverage Fully Interoperable with IEEE 802.11b/IEEE 802.11g/IEEE 802.11n-compliant devices Multi-function capabilities enable users to use different modes in various environments 1-2 Point-to-point and point-to-multipoint wireless connectiv-
ity enable data transfers between two or more buildings Channel bandwidth selection allows the appropriate band-
width to be used to reach various distances RSSI indicator makes it easy to select the best signal for Access Point connections Power-over-Ethernet capabilities allow for flexible installa-
tion locations and cost savings Four SSIDs let clients access different networks through a single Access Point, and assign different policies and functions for each SSID WPA2/WPA/ WEP/ IEEE 802.1x support and MAC address filtering ensure secure network connections PPPoE/PPTP function support make it easy to access the Internet via Internet Service Provider (ISP) service authentication SNMP Remote Configuration Management helps adminis-
trators remotely configure or manage the Access Point QoS (WMM) support enhances performance and user experiences PRODUCT OVERVIEW BENEFITS Wireless extensions to Ethernet networks WLANs enable network managers in dynamic environments to minimize overhead caused by moves, extensions to networks, and other changes. Wired LAN backup Network managers can implement WLANs to provide backup for mission-critical applications running on wired networks. Mobility within training/educational facilities Training sites at corporations and students at universities are a few examples where wireless connectivity can be used to facili-
tate access to information, information exchanges, and learn-
ing. Benefits The EnStation2 is the ideal product around which you can build your WLAN. The following list summarizes a few key advan-
tages that WLANs have over wired networks:
Ideal for hard-to-wire environments There are many scenarios where cables cannot be used to con-
nect networking devices. Historic and older buildings, open areas, and busy streets, for example, make wired LAN installa-
tions difficult, expensive, or impossible. Temporary workgroups WLANs make it easy to provide connectivity to temporary work-
groups that will later be removed. Examples include parks, ath-
letic arenas, exhibition centers, disaster-recovery shelters, temporary offices, and construction sites. Ability to access real-time information With a WLAN, workers who rely on access to real-time informa-
tion, such as doctors and nurses, point-of-sale employees, mobile workers, and warehouse personnel, can access the data they need and increase productivity, without having to look for a place to plug into the network. Frequently changed environments WLANs are well suited for showrooms, meeting rooms, retail stores, and manufacturing sites where workplaces are rear-
ranged frequently. 1-3 TECHNICAL SPECIFICATION PRODUCT OVERVIEW Technical Specification Wireless Specification IEEE802.11b/g/n, 2T2R, 300Mbps 2.400 to 2.484 GHz Hardware Specification Physical Interface: 2 x 10/100Mbps LAN Ports, 1 x Reset Button Power Supply: Passive PoE, 24V/0.6A Power Adapter Dimension: 190(D)x38mm(H) Operation Temperature: -20C ~ 60C Embedded high gain directional antenna Software Specification Operation Mode: Client Bridge, Access Point, Client Router, WDS AP, WDS Bridge, WDS Station Multiple SSID, Preferred SSID PPPoE, PPTP, L2TP Pass-through WMM, Traffic Shaping CLI Interface, SNMP v1/v2c/v3 Recovery Page Port Forwarding/DMZ Narrow Bandwidth 1-4 PRODUCT OVERVIEW 1.3 Product Interface PRODUCT INTERFACE BACK PANEL VIEW DESCRIPTION F WAN LED
(Access Point or Client Bridge Mode) OFF=EnStation radio is off and the device is not sending or receiving data over the wireless LAN ON=EnStation radio is on, and the device is not sending or receiving data over the wireless LAN. Blinking=EnStation radio is on, and the device is sending or receiving data over the wireless LAN. G Signal Indicator LED (Client Bridge, WDS Station and Client Router Mode) Figure 1-1: Back Panel View BACK PANEL VIEW LAN Port(PoE) LAN Port Reset Button Power LED LAN(2) LEDs DESCRIPTION The PoE interface allows EnStation to be powered using the supplied PoE injector To configure EnStation, connect to an Ethernet adapter in a computer for accessing more information To reset factory settings, press button more than 10seconds. OFF=EnStation is not receiving power ON=EnStation is receiving power OFF=EnStation is not connected to the network ON=Enstation is connected to the network but not sending or receiving data A B C D E 1-5 Installation Chapter 2 INSTALLATION SYSTEM REQUIREMENTS 2.1 System Requirements To install the EnStation2, you need the following:
ComputComputer (Windows, Linux, Mac OS X Operating System) Web Browser (Internet Explorer, FireFox, Chrome, Safari) Network Interface equipped: (one of the following) Wired connectivity: Network Interface with an open RJ-45 Ethernet Port Wireless Connectivity:
Embedded 802.11n Wi-Fi wireless networking, IEEE 802.11b/g compatible Wi-Fi Card, USB Wi-Fi Dongle (802.11 b/g/n) An existing router or access point (AP) with SSID broad-
cast 1x CAT5e Ethernet Cable 2-1 INSTALLATION INSTALLING THE DEVICE Installing the Device To install the EnStation2, use the following procedure to mount the device on a pole and refer to the figure below. 1. Remove the bottom cover protecting the RJ-45 connec-
tors. Insert an Ethernet cable into the RJ-45 port labeled LAN. 2. 3. Install the bottom cover to protect the RJ-45 connectors. 4. Remove the power cord and PoE injector from the box and plug the power cord into the DC port of the PoE injec-
tor.
CAUTION!
ONLY USE THE POWER ADAPTER SUPPLIED WITH THE ENSTATION2. USING A DIFFERENT POWER ADAPTER MIGHT DAMAGE THE ENSTATION2. 2.2 Installing the Device Installing the EnStation2 on a pole or wall optimizes the wire-
less access range. Note:
Only experienced installation professionals who are famil-
iar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities should install the EnStation2. Pre-Installation Guidelines Select the optimal location for the equipment using the following guidelines:
The EnStation2 should be mounted on a 1"-4" pole. Its location should enable easy access to the unit and its con-
nectors for installation and testing. The higher the placement of the antenna, the better the achievable link quality. The antenna should be installed to provide a direct, or near line of sight with the Base Station antenna. The antenna should be aligned to face the general direction of the Base Station. 2-2 INSTALLATION WALL MOUNTING THE DEVICE 5. Plug the other end of the Ethernet cable into the PoE port of the PoE injector. Wall Mounting the Device 1. Plug the dynamic stick into the bracket firstly. 2. Combine the sealing nut and the assembled kit, as well as tighten it. 3. Put the mock washer on dynamic stick. 4. Assemble the mounting kit with the CPE. 5. Drill the hole to input the mounting screws. 6. Use the included screws to input the mounting screws. 7. Let the hole of the bracket to aim at the screws on the wall and hang the device to fix it. Figure 2-1: Installing the EnStation2 6. Turn over the EnStation2. Then insert the pole mounting strap through the middle hole of the EnStation2. Use a screwdriver to unlock the pole-mounting ring putting it through the EnStation2. 7. Mount the EnStation2 securely to the pole by locking the strap tightly. This completes the installation procedure. Figure 2-2: Wall Mounting the Device 2-3 INSTALLATION POLE MOUNTING THE DEVICE Pole Mounting the Device 1. Plug the dynamic stick into the bracket firstly. 2. Combine the sealing nut and the assembled kit, as well as tighten it. 3. Put the mock washer on dynamic stick. 4. Assemble the mounting kit with the CPE. 5. Thread the open end of the pole strap through the two tabs on the bracket. 6. Lock and tighten pole strap to secure bracket to the pole. Figure 2-3: Pole Mounting the Device 2-4 Web Configuration Chapter 3 WEB CONFIGURATION 3.1 Logging In The EnStation2 has a built-in Web Configurator that lets you manage the unit from any location using a Web browser that supports HTTP and has Javascript installed. After configuring the computer for TCP/IP using the procedure appropriate for your operating system, use that computers Web browser to log in to the EnStation2 Web Configurator. 1. Launch your Web browser. 2. In the browser address bar, type 192.168.1.1 and press the Enter key. Note:
If you changed the EnStation2 LAN IP address, enter the correct IP address. Figure 3-1: Web Browser Address Bar LOGGING IN 3. When the login screen appears, enter admin for the user-
name in the top field and admin for the password in the bottom field. Figure 3-2: Windows Security Login Dialog 4. Click Login to continue or Reset to abort the login. You are now ready to use the instructions in the following chap-
ters to configure the EnStation2. 3-1 WEB CONFIGURATION BEST PRACTICES Best Practices Perform the following procedures regularly to make the EnStation2 more secure and manage the EnStation2 more effectively. Change the default password Use a password that is not easy to guess and that contains different characters, such as numbers and letters. The EnStation2 username cannot be changed. For more information, see Configur-
ing Administrator Account. Back up the configuration and be sure you know how to restore it. Restoring an earlier working configuration can be useful if the EnStation2 becomes unstable or crashes. If you forget your password, you will have to reset the EnStation2 to its factory default settings and lose any cus-
tomized override settings you configured. However, if you back up an earlier configuration, you will not have to com-
pletely reconfigure the EnStation2. You can simply restore your last configuration. For more information, see Config-
uring Backup/Restore Settings. 3-2 Basic Network Settings Chapter 4 BASIC NETWORK SETTINGS 4.1 System Status SYSTEM STATUS View the summary of the current system status including system (hardware/software version, date/time), wired network (LAN) and wireless network (WLAN) information. 4.1.1 Using Save/Reload Save and apply the settings shown in the Unsaved changes list, or cancel the unsaved changes and revert to the previous set-
tings that were in effect. 4-1 BASIC NETWORK SETTINGS VIEWING SYSTEM INFORMATION 4.1.2 Viewing System Information Displays status information about the current operating mode. System Information shows the general system information such as operating mode, system up time, firmware version, serial number, kernel version, and application version. LAN Settings shows Local Area Network settings such as the LAN IP address, subnet mask, and MAC address. 4-2 BASIC NETWORK SETTINGS VIEWING SYSTEM INFORMATION WAN Settings shows Wide Area Network settings such as the MAC address, connection type, connection status, LAN IP address, subnet mask, primary and secondary DNS. Current Wireless Settings shows wireless information such as frequency and channel. Since the EnStation2 supports multiple-
SSIDs, information about each SSID, such as its ESSID and security settings, are displayed. 4-3 BASIC NETWORK SETTINGS VIEWING WIRELESS CLIENT LIST 4.1.3 Viewing Wireless Client List Displays a list of clients associated to the EnStation2, along with the MAC addresses and signal strength for each client. To remove an SSID client from the list, click the button that appears in the Kick and Ban column. Click the Refresh button to update the client list. 4-4 BASIC NETWORK SETTINGS VIEWING SYSTEM LOG 4.1.4 Viewing System Log The EnStation2 automatically logs events to internal memory. Note:
The oldest events are deleted from the log when memory is full. Click the Refresh button to update the client list or the Clear button to remove all events. 4-5 BASIC NETWORK SETTINGS VIEWING CONNECTION STATUS 4.1.5 Viewing Connection Status Displays the current status of the network. The WLAN information shown includes network type, SSID, BSSID, connection status, wireless mode, current channel, security, data rate, noise level, and signal strength. The WAN information shown includes the MAC address, connection type, connection status, IP address, IP subnet mask, primary DNS and secondary DNS. Click the Refresh button to update the client list or the Clear button to remove all events. 4-6 BASIC NETWORK SETTINGS VIEWING DHCP CLIENT TABLE 4.1.6 Viewing DHCP Client Table Displays the clients that are associated to the EnStation2 through DHCP. The MAC addresses and signal strength for each client are also shown. Click the Refresh button to update the client list. 4-7 BASIC NETWORK SETTINGS VIEWING WDS LINK LIST 4.1.7 Viewing WDS Link List Displays the clients that are associated to the EnStation2 through WDS. The MAC addresses, link status and signal strength for each client are also shown. Click the Refresh button to update the client list. 4-8 BASIC NETWORK SETTINGS 4.2 System Setup SYSTEM SETUP The following sections explain the features and functionality of the EnStation2 in access point mode, client bridge mode, WDS access point mode, WDS bridge mode, WDS station mode and client router mode. 4.2.1 Configuring Operation Mode Set the primary function of the device. The function that is selected affects which items are available in the main menu. Device Name Enter a name for the device. The name you type appears in SNMP management. This name is not the SSID and is not broadcast to other devices. Operation Mode Use the radio button to select an operating mode. Click Save & Apply to save changes or Cancel to abort. 4-9 BASIC NETWORK SETTINGS CONFIGURING IP SETTINGS 4.2.2 Configuring IP Settings Configure the EnStation2 LAN settings for the EnStation2 using a static or dynamic IP address. IP Network Setting Configure the network connection type using either a static IP or dynamic IP. IP Address Enter the LAN IP address of the EnStation2. Subnet Mask Enter the subnet mask of the EnStation2. Default Gateway Enter the default gateway of the EnStation2. Primary DNS Enter the primary DNS address of the EnStation2. Secondary DNS Enter the secondary DNS address of the EnStation2. Use Link-Local Address Click to enable a link-local address for the device. IPv6 IP Address Enter the IPv6 LAN IP address of the EnStation2. IPv6 Subnet Prefix Length Enter the IPv6 subnet prefix length of the EnStation2. IPv6 Default Gateway Enter the IPv6 default gateway of the EnStation2. IPv6 Primary DNS Enter the IPv6 primary DNS of the EnStation2. IPv6 Secondary DNS Enter the IPv6 secondary DNS of the EnStation2. Click Apply to save the settings or Cancel to discard changes. 4-10 BASIC NETWORK SETTINGS CONFIGURING SPANNING TREE SETTINGS 4.2.3 Configuring Spanning Tree Settings Spanning Tree Status Enable or disable the EnStation2 Spanning Tree function. Bridge Hello Time Specify Bridge Hello Time, in seconds. This value determines how often the EnStation2 sends hello packets to communicate information about the topology throughout the entire Bridged Local Area Network Bridge Max Age Specify Bridge Max Age, in seconds. If another bridge in the spanning tree does not send a hello packet for a long period of time, it is assumed to be dead. Bridge Forward Delay Specify Bridge Forward Delay, in seconds. Forwarding delay time is the time spent in each of the Listening and Learning states before the Forwarding state is entered. This delay is provided so that when a new bridge comes onto a busy network, it looks at some traffic before participating. Priority Specify the Priority number. Smaller numbers have greater priority. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-11 BASIC NETWORK SETTINGS 4.3 Router Setup ROUTER SETUP 4.3.1 Configuring WAN Settings Configure the WAN settings for the EnStation2 using a static or dynamic IP address, PPPoE or PPTP. Static IP Setting a static IP address allows an administrator to set a specific IP address for the router and guar-
antees that it can not be assigned a different address. Account Name Enter the account name provided by your ISP. Domain Name Enter the domain name provided by your ISP. MTU The maximum transmission unit (MTU) specifies the largest packet size permitted for an internet transmission. The factory default MTU size for static IP is 1500. The MTU size can be set between 576 and 1500. IP Address Enter the routers WAN IP address. Subnet Mask Enter the routers WAN subnet mask. Default Gateway Enter the WAN gateway address. Primary DNS Enter the primary DNS server address. 4-12 BASIC NETWORK SETTINGS DYNAMIC IP Secondary DNS Enter the secondary DNS server address. Discard Ping on WAN Check to Enable to recognize pings on the EnStation2 WAN interface or Disable to block pings on the EnStation2 WAN interface. Note: Pinging IP addresses is a common method used by hackers to test whether the IP address is valid. Blocking pings provides some extra security from hackers. Click Accept to save the settings or Cancel to discard changes. Dynamic IP Dynamic IP addressing assigns a different IP address each time a device connects to an ISP service provider. The service is most commonly used by ISP cable providers. Account Name Enter the account name provided by your ISP. Domain Name Enter the domain name provided by your ISP. MTU The maximum transmission unit (MTU) specifies the largest packet size permitted for an internet transmission. The factory default MTU size for Dynamic IP is 1500. The MTU size can be set between 576 and 1500. Get Automatically From ISP Click the radio button to obtain the DNS automatically from the DHCP server. Use These DNS Servers Click the radio button to set up the Primary DNS and Secondary DNS servers manually. Discard Ping on WAN Check to Enable to recognize pings on the EnStation2 WAN interface or Disable to block pings on the EnStation2 WAN interface. Note: Pinging IP addresses is a common method used by hackers to test whether the IP address is valid. Blocking pings provides some extra security from hackers. Click Accept to save the settings or Cancel to discard changes. 4-13 BASIC NETWORK SETTINGS POINT-TO-POINT PROTOCOL OVER ETHERNET (PPPOE) Point-to-Point Protocol over Ethernet (PPPoE) Point-to-Point Protocol over Ethernet (PPPoE) is used mainly by ISPs that provide DSL modems to connect to the Internet. MTU Enter the maximum transmission unit (MTU). The MTU specifies the largest packet size permitted for an internet transmission (PPPoE default: 1492). The MTU size can be set between 576 and 1492. Login Enter the username assigned by an ISP. Password Enter the password assigned by an ISP. Service Name Enter the service name of an ISP
(optional). Connect on Demand Select the radio button to specify the maximum idle time. Internet connection will disconnect when it reach the maximum idle time, but it will automatically connect when user tries to access the network. Keep Alive Select whether to keep the Internet connection always on, or enter a redial period once the internet lose connection. Get Automatically From ISP Click the radio button to obtain the DNS automatically from the ISP. Use These DNS Servers Click the radio button to set up the Primary DNS and Secondary DNS servers manually. Discard Ping on WAN Check to Enable to recognize pings on the EnStation2 WAN interface or Disable to block pings on the EnStation2 WAN interface. Note: Pinging IP addresses is a common method used by hackers to test whether the IP address is valid. Blocking pings provides some extra security from hackers. Click Accept to save the settings or Cancel to discard changes. 4-14 BASIC NETWORK SETTINGS POINT-TO-POINT TUNNELLING PROTOCOL (PPTP) Point-to-Point Tunnelling Protocol (PPTP) The point-to-point tunnelling protocol (PPTP) is used in association with virtual private networks
(VPNs). There a two parts to a PPTP connection:
the WAN interface settings and the PPTP settings. MTU Enter the maximum transmission unit (MTU). The MTU specifies the largest packet size permitted for an internet transmission (PPPoE default: 1400). The MTU size can be set between 1200 and 1400. IP Address Enter the routers WAN IP address. Subnet Mask Enter the routers WAN subnet IP address. Default Gateway Enter the routers WAN gateway IP address. PPTP Server Enter the IP address of the PPTP server. Username Enter the username provided by your ISP. Password Enter the password provided by your ISP. Connect on Demand If you want the EnStation2 to end the Internet connection after it has been inactive for a period of time, select this option and enter the number of minutes you want that period of inactivity to last. Keep Alive If you want the EnStation2 to periodically check your Internet connection, select this option. Then specify how often you want the EnStation2 to check the Internet connection. If the connection is down, the EnStation2 automatically re-establishes your connection Get Automatically From ISP Obtains the DNS automatically from ISP. 4-15 BASIC NETWORK SETTINGS POINT-TO-POINT TUNNELLING PROTOCOL (PPTP) Use These DNS Servers Click the radio button to set up the Primary DNS and Secondary DNS servers manually. Discard Ping on WAN Check to Enable to recognize pings on the EnStation2 WAN interface or Disable to block pings on the EnStation2 WAN interface. Note: Pinging IP addresses is a common method used by hackers to test whether the IP address is valid. Blocking pings provides some extra security from hackers. Click Accept to save the settings or Cancel to discard changes. 4-16 BASIC NETWORK SETTINGS CONFIGURING LAN SETTINGS 4.3.2 Configuring LAN Settings IP Address Enter the LAN port IP address. IP Subnet Mask Enter the LAN IP subnet mask. WINS Server IP Enter the WINS Server IP. Use Router As DHCP Server Check this option to enable the EnStation2 internal DHCP server. Starting IP Address Specify the starting IP address range for the pool of allocated for private IP addresses. The starting IP address must be on the same subnet as the ending IP address;
that is the first three octets specified here must be the same as the first three octets in End IP Address. Ending IP Address Specify the ending IP address range for the pool of allocated for private IP addresses. The ending IP address must be on the same subnet as the starting IP address; that is the first three octets specified here must be the same as the first three octets in Start IP Address. WINS Server IP Enter the IP address of the WINS server. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-17 BASIC NETWORK SETTINGS CONFIGURING VPN PASS-THROUGH 4.3.3 Configuring VPN Pass-Through VPN Pass-through allows a secure virtual private network (VPN) connection between two computers. Enabling the options on this page opens a VPN port and enables connections to pass through the EnStation2 without interruption. PPTP Pass-through Check this option to enable PPTP pass-through mode. L2TP Pass-through Check this option to enable L2TP pass-through mode. IPSec Pass-through Check this option to enable IPSec pass-through mode. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-18 BASIC NETWORK SETTINGS CONFIGURING PORT FORWARDING 4.3.4 Configuring Port Forwarding Port forwarding enables multiple server applications on a LAN to serve clients on a WAN over a single WAN IP address. The router accepts incoming client packets, filters them based on the destination WAN, or public, port and protocol and forwards the packets to the appropriate LAN, or local, port. Unlike the DMZ feature, port forwarding protects LAN devices behind the firewall. NO. Displays the sequence number of the forwarded port. Name Displays the name of the forwarded port. Protocol Displays the protocol to use for mapping from the following: TCP, UDP or Both. Start Port Displays the LAN port number that WAN client packets will be forward to. End Port Displays the port number that the WAN client packets are received. Server IP Displays the IP address of the server for the forwarded port. Enable Click to enable or disable the forwarded port profile. Modify Click to modify the forwarded port profile. Delete Click to delete the forwarded port profile. Click Add Entry to add port forwarding rules. Click Accept to confirm the changes. 4-19 BASIC NETWORK SETTINGS CONFIGURING PORT FORWARDING Service Name Enter a name for the port forwarding rule. Protocol Select a protocol for the application: Choices are Both, TCP, and UDP. Starting Port Enter a starting port number. Ending Port Enter an ending port number. All ports numbers between the starting and ending ports will forward users to the IP address specified in the IP Address field. IP Address Enter the IP address of the server computer on the LAN network where users will be redirected. Click Save to apply the changes or Cancel to return previous settings. 4-20 BASIC NETWORK SETTINGS CONFIGURING DEMILITARIZED ZONE 4.3.5 Configuring Demilitarized Zone Configuring a device on the LAN as a demilitarized zone (DMZ) host allows unrestricted two-way Internet access for Internet applica-
tions, such as online video games, to run from behind the NAT firewall. The DMZ function allows the router to redirect all packets going to the WAN port IP address to a particular IP address on the LAN. The difference between the virtual server and the DMZ func-
tion is that a virtual server redirects a particular service or Internet application, such as FTP, to a particular LAN client or server, whereas a DMZ redirects all packets, regardless of the service, going to the WAN IP address to a particular LAN client or server.
WARNING!
The PC defined as a DMZ host is not protected by the firewall and is vulnerable to malicious network attacks. Do not store or manage sensitive information on the DMZ host. DMZ Hosting Select Enable DMZ to activate DMZ functionality. DMZ Address Enter an IP address of a device on the LAN. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-21 BASIC NETWORK SETTINGS CONFIGURING WIRELESS LAN 4.4 Configuring Wireless LAN 4.4.1 Configuring Wireless Settings Instructions on how to configure the wireless and security settings for each of the possible operating modes.
WARNING!
Incorrectly changing these settings may cause the device to stop functioning. Do not modify the settings in this section without a thor-
ough understanding of the parameters. Access Point Mode The EnStation2 supports Access Point Mode. In this mode, users with a wireless client device within range can connect to the EnStation2 to access the WLAN. Wireless Mode Wireless mode supports 802.11b/
g/n mixed modes. Channel HT Mode The default channel bandwidth is 20/40 MHz. The larger the channel, the better the transmission quality and speed. Extension Channel Select upper or lower channel. Your selection may affect the Auto channel function. Channel / Frequency Select the channel and frequency appropriate. Auto Check this option to enable auto-channel selection. 4-22 BASIC NETWORK SETTINGS ACCESS POINT MODE AP Detection AP Detection can select the best channel to use by scanning nearby areas for Access Points. Current Profile Configure up to four different SSIDs. If many client devices will be accessing the network, you can arrange the devices into SSID groups. Click Edit to configure the profile and check whether you want to enable extra SSIDs. Click Accept to confirm the changes or Cancel to cancel and return previous settings. SSID Specify the SSID for the current profile. VLAN ID Specify the VLAN tag for the current profile. Suppressed SSID Check this option to hide the SSID from clients. If checked, the SSID will not appear in the site survey. Station Separation Click the appropriate radio button to allow or prevent communication between client devices. Wireless Security See the Wireless Security section. Click Save to accept the changes or Cancel to cancel and return previous settings. 4-23 BASIC NETWORK SETTINGS CLIENT BRIDGE MODE Client Bridge Mode Client Bridge Mode lets you connect two LAN segments via a wireless link as though they are on the same physical network. Since the computers are on the same subnet, broadcasts reach all machines. As a result, DHCP information generated by the server reach all client computers as though the clients residing on one physical network. Wireless Mode Wireless mode supports 802.11b/
g/n mixed modes. SSID Specify the SSID if known. This field is completed automatically if you select an Access Point in the Site Survey. Site Survey Scans nearby locations for Access Points. You can select a discovered Access Point to establish a connection. Prefer BSSID Enter the MAC address if known. If you select an Access Point in the Site Survey, this field is completed automatically. Wireless Security For details on wireless security settings, see Configuring Wireless Security. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-24 BASIC NETWORK SETTINGS CLIENT BRIDGE MODE Profile If you used the Site Survey, the Web Configurator shows nearby Access Points. To connect to an Access Point, click the Access Points BSSID. Wireless Security See Configuring Wireless Security. Click Refresh to scan again. 4-25 BASIC NETWORK SETTINGS WDS BRIDGE MODE WDS Bridge Mode Unlike traditional bridging. WDS Bridge Mode allows you to create large wireless networks by linking several wireless access points with WDS links. WDS is normally used in large, open areas, where pulling wires is cost prohibitive, restricted or physically impossible. Wireless Mode Wireless mode supports 802.11b/g/n mixed modes. Channel HT Mode The default channel bandwidth is 40 MHz. The larger the channel, the better the transmission quality and speed. Extension Channel Select upper or lower channel. Your selection may affect the Auto channel function. Channel / Frequency Select the channel and frequency appropriate. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-26 BASIC NETWORK SETTINGS WDS BRIDGE MODE Security Select the type of WDS security: None, WEP, or AES. WEP Key Enter the WEP key. AES Pass phrase Enter the AES pass phrase. MAC Address Enter the MAC address of the Access Point to which you want to extend wireless connectivity. Mode Select Disable or Enable to disable or enable WDS. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-27 BASIC NETWORK SETTINGS CLIENT ROUTER MODE Client Router Mode In Client Router Mode, you can access the Internet wirelessly with the support of a WISP. In AP Router Mode, the EnStation2 can access the Internet via a cable or DSL modem. In this mode, the EnStation2 can be configured to turn off the wireless network name
(SSID) broadcast, so that only stations that have the SSID can be connected. The EnStation2 also provides wireless LAN 64/128/
156-bit WEP encryption security, WPA/WPA2, and WPA-PSK/WPA2-PSK authentication, as well as TKIP/AES encryption security. It also supports VPN pass-through for sensitive data secure transmission. Wireless Mode Wireless mode supports 802.11b/
g/n mixed modes. SSID Specify the SSID if known. This field is completed automatically if you select an Access Point in the Site Survey. Site Survey Scans nearby locations for Access Points. You can select a discovered Access Point to establish a connection. Prefer BSSID Enter the MAC address if known. If you select an Access Point in the Site Survey, this field is completed automatically. Wireless Security See Configuring Wireless Security. Click Accept to confirm the changes or Cancel to cancel and return previous settings. 4-28 BASIC NETWORK SETTINGS CLIENT ROUTER MODE Profile If you used the Site Survey, the Web Configurator shows nearby Access Points. To connect to an Access Point, click the Access Points BSSID. Wireless Security See Configuring Wireless Security. Click Refresh to scan again. 4-29 BASIC NETWORK SETTINGS CONFIGURING WIRELESS SECURITY 4.4.2 Configuring Wireless Security The Wireless Security Settings section lets you configure the EnStation2s security modes: WEP, WPA-PSK, WPA2-PSK, WPA-PSK Mixed, WPA, WPA2, and WPA Mixed. We strongly recommend you use WPA2-PSK. Wired Equivalent Privacy (WEP) Security Mode Select WEP from the drop-down list to begin the configuration. Auth Type Select Open System or Shared. Input Type Select an input type of Hex or ASCII. Key Length Level of WEP encryption applied to all WEP keys. Select a 64/128/152-bit password lengths. Default Key Specify which of the four WEP keys the EnStation2 uses as its default. Key1 - Key4 Specify a password for the security key index. For security, each typed character is masked by a dot. Click Save to save the changes or Cancel to cancel and return previous settings. Note:
802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-30 BASIC NETWORK SETTINGS WI-FI PROTECTED ACCESS PRE-SHARED KEY (WPA-PSK) Wi-Fi Protected Access Pre-Shared Key (WPA-PSK) Security Mode Select WPA-PSK from the drop-down list to begin the configuration. Encryption Select Both, TKIP, or AES as the encryption type. Both = uses TKIP and AES. TKIP = automatic encryption with WPA-PSK; requires pass-
phrase. AES = automatic encryption with WPA2-PSK; requires passphrase. Passphrase Specify the security password. For security, each typed character is masked by a dot. Group Key Update Interval Specify how often, in seconds, the group key changes. Click Save to save the changes or Cancel to cancel and return previous settings. Note:
802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-31 BASIC NETWORK SETTINGS WI-FI PROTECTED ACCESS 2 PRE-SHARED KEY (WPA2-PSK) Wi-Fi Protected Access 2 Pre-Shared Key (WPA2-PSK) Security Mode Select WPA2-PSK from the drop-down list to begin the configuration. Encryption Select Both, TKIP, or AES as the encryption type. Both = uses TKIP and AES. TKIP = automatic encryption with WPA-PSK; requires pass-
phrase. AES = automatic encryption with WPA2-PSK; requires passphrase. Passphrase Specify the security password. For security, each typed character is masked by a dot. Group Key Update Interval Specify how often, in seconds, the group key changes. Click Save to save the changes or Cancel to cancel and return previous settings. Note:
802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-32 BASIC NETWORK SETTINGS WI-FI PROTECTED ACCESS PRE-SHARED KEY (WPA-PSK) MIXED Wi-Fi Protected Access Pre-Shared Key (WPA-PSK) Mixed Security Mode Select WPA2-PSK Mixed from the drop-down list to begin the configuration. Encryption Select Both, TKIP, or AES as the encryption type. Both = uses TKIP and AES. TKIP = automatic encryption with WPA-PSK; requires pass-
phrase. AES = automatic encryption with WPA2-PSK; requires passphrase. Passphrase Specify the security password. For security, each typed character is masked by a dot. Group Key Update Interval Specify how often, in seconds, the group key changes. Click Save to save the changes or Cancel to cancel and return previous settings. Note:
WPA-PSK Mixed can allow multiple security modes at the same time. 802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-33 BASIC NETWORK SETTINGS WI-FI PROTECTED ACCESS (WPA) Wi-Fi Protected Access (WPA) Security Mode Select WPA from the drop-down list to begin the configuration. Encryption Select Both, TKIP, or AES as the encryption type. Both = uses TKIP and AES. TKIP = automatic encryption with WPA-PSK; requires pass-
phrase. AES = automatic encryption with WPA2-PSK; requires passphrase. Radius Server Specify the IP address of the RADIUS server. Radius Port Specify the port number that your RADIUS server uses for authentication. Default port is 1812. Radius Secret Specify RADIUS secret furnished by the RADIUS server. Group Key Update Interval Specify how often, in seconds, the group key changes. Radius Accounting Select to enable or disable RADIUS accounting. Radius Accounting Server Specify the IP address of the RADIUS accounting server. Radius Accounting Port Specify the port number that your RADIUS accounting server uses for authentication. Default port is 1813. Radius Accounting Secret Specify RADIUS accounting secret furnished by the RADIUS server. Interem Accounting Interval Specify the interem accounting interval (60 - 600 seconds). Click Save to save the changes or Cancel to cancel and return previous settings. Note:
802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-34 BASIC NETWORK SETTINGS WI-FI PROTECTED ACCESS 2 (WPA2) Wi-Fi Protected Access 2 (WPA2) Security Mode Select WPA2 from the drop-down list to begin the configuration. Encryption Select Both, TKIP, or AES as the encryption type. Both = uses TKIP and AES. TKIP = automatic encryption with WPA-PSK; requires pass-
phrase. AES = automatic encryption with WPA2-PSK; requires passphrase. Radius Server Specify the IP address of the RADIUS server. Radius Port Specify the port number that your RADIUS server uses for authentication. Default port is 1812. Radius Secret Specify RADIUS secret furnished by the RADIUS server. Group Key Update Interval Specify how often, in seconds, the group key changes. Radius Accounting Select to enable or disable RADIUS accounting. Radius Accounting Server Specify the IP address of the RADIUS accounting server. Radius Accounting Port Specify the port number that your RADIUS accounting server uses for authentication. Default port is 1813. Radius Accounting Secret Specify RADIUS accounting secret furnished by the RADIUS server. Interem Accounting Interval Specify the interem accounting interval (60 - 600 seconds). Click Save to save the changes or Cancel to cancel and return previous settings. Note:
802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-35 BASIC NETWORK SETTINGS WI-FI PROTECTED ACCESS (WPA) MIXED Wi-Fi Protected Access (WPA) Mixed Security Mode Select WPA Mixed from the drop-down list to begin the configuration. Encryption Select Both, TKIP, or AES as the encryption type. Both = uses TKIP and AES. TKIP = automatic encryption with WPA-PSK; requires pass-
phrase. AES = automatic encryption with WPA2-PSK; requires passphrase. Radius Server Specify the IP address of the RADIUS server. Radius Port Specify the port number that your RADIUS server uses for authentication. Default port is 1812. Radius Secret Specify RADIUS secret furnished by the RADIUS server. Group Key Update Interval Specify how often, in seconds, the group key changes. Radius Accounting Select to enable or disable RADIUS accounting. Radius Accounting Server Specify the IP address of the RADIUS accounting server. Radius Accounting Port Specify the port number that your RADIUS accounting server uses for authentication. Default port is 1813. Radius Accounting Secret Specify RADIUS accounting secret furnished by the RADIUS server. Interem Accounting Interval Specify the interem accounting interval (60 - 600 seconds). Click Save to save the changes or Cancel to cancel and return previous settings. Note:
802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will change from 802.11n to 802.11g. 4-36 BASIC NETWORK SETTINGS CONFIGURING WIRELESS MAC FILTER 4.4.3 Configuring Wireless MAC Filter Note:
This section applies to Access Point and WDS Access point mode. Wireless MAC Filters are used to allow or deny network access to wireless clients according to their MAC addresses. You can manu-
ally add a MAC address to restrict the permission to access EnStation2. The default setting is Disable Wireless MAC Filters. ACL Mode Determines whether network access is granted or denied to clients whose MAC addresses appear in the MAC Address table on this page. Choices are Disable, Deny MAC in the list, or Allow MAC in the list. MAC Address Filter Enter the MAC address of the device. Click Add to add the MAC address to the MAC Address table. Click Apply to apply the changes. 4-37 BASIC NETWORK SETTINGS CONFIGURING WDS LINK SETTINGS 4.4.4 Configuring WDS Link Settings Using WDS Link Settings, you can create a wireless backbone link between multiple access points that are part of the same wireless network. This allows a wireless network to be expanded using multiple Access Points without the need for a wired backbone to link them, as is traditionally required. Security Select the type of WDS security: None, WEP, or AES. WEP Key Enter the WEP key. AES Passphrase Enter the AES passphrase. MAC Address Enter the MAC address of the Access Point to which you want to extend wireless connectivity. Mode Select Disable or Enable to disable or enable WDS. Click Accept to confirm the changes or Cancel to cancel and return previous settings. Note:
The Access Point to which you want to extend wireless connectivity must enter the EnStation2s MAC address into its configuration. For more information, refer to the documentation for the Access Point. Not all Access Point supports this feature. 4-38 BASIC NETWORK SETTINGS CONFIGURING ADVANCED NETWORK SETTINGS 4.4.5 Configuring Advanced Network Settings Configure the advanced wireless settings for your access point using the screens in this section. Leave these settings to their default values if you are not sure what values to enter. Data Rate Select a data rate from the drop-down list. The data rate affects throughput. If you select a low data rate value, for example, the throughput is reduced but the transmission distance increases. Transmit Power Lets you increase or decrease transmit power. Higher transmit power may prevent connections to the network, while the lower transmit power can prevent clients from connecting to the device. RTS/CTS Threshold Specify the threshold package size for RTC/CTS. A small number causes RTS/CTS packets to be sent more often and consumes more bandwidth. Distance Specify the distance between Access Points and clients. Longer distances may drop high-speed connections. Aggregation Merges data packets into one packet. This option reduces the number of packets, but increases packet sizes. Wireless Traffic Shaping Enable Traffic Shaping Enable or disable the regulation of packet flow leaving an interface for improved QoS. Incoming Traffic Limit Specify the wireless transmission speed used for downloading. Outgoing Traffic Limit Specify the wireless transmission speed used for uploading. Total Percentage Specify the total percentage of the wireless traffic that is shaped. SSID1 to SSID4 Specify the percentage of the wireless traffic that is shaped for a specific SSID. 4-39 BASIC NETWORK SETTINGS MANAGEMENT SETUP 4.5 Management Setup The Management section lets you configure administration, management VLAN, SNMP settings, backup/restore settings, firmware upgrade, time settings, and log settings. This chapter describes these settings. 4.5.1 Configuring Administrator Account Click the Administration link under the Management menu to change the user name and password used to log on to the EnStation2 Web Configurator. The default user name is admin and the default password is admin. Changing these settings protects the EnStation2 configuration settings from being accessed by unauthorized users. New Name Enter a new username for logging in to the Web Configurator. New Password Enter a new password for logging in to the Web Configurator Confirm Password Re-enter the new password for confirmation. Click Save/Apply to apply the changes or Cancel to return previous settings. Remote Management Enable or disable remote management. Remote Upgrade Specify whether the EnStation2 firmware can be upgraded remotely. Remote Management Port If remote management is enabled, enter the port number to be used for remote management. For example: If you specify the port number 8080, enter http://<IP address>:8080 to access the EnStation2 Web Configurator. Click Accept to apply the changes or Cancel to return previous settings. 4-40 BASIC NETWORK SETTINGS CONFIGURING MANAGEMENT VLAN 4.5.2 Configuring Management VLAN Click the Management VLAN link under the Management menu to assign a VLAN tag to the packets. A VLAN is a group of computers on a network whose software has been configured so that they behave as if they were on a separate Local Area Network (LAN). Computers on VLAN do not have to be physically located next to one another on the LAN. Management VLAN ID If your network includes VLANs and if tagged packets need to pass through the Access Point, enter the VLAN ID. Otherwise, click No VLAN tag. Click Accept to confirm the changes or Cancel to cancel and return previous settings. Note:
If you reconfigure the Management VLAN ID, you may lose your connection to the EnStation2. Verify that the DHCP server supports the reconfigured VLAN ID and then reconnect to the EnStation2 using the new IP address. 4-41 BASIC NETWORK SETTINGS CONFIGURING SNMP 4.5.3 Configuring SNMP SNMP is used in network management systems to monitor network-attached devices for conditions that warrant administrative atten-
tion. SNMP Enable or disable the EnStation2 SNMP function. Contact Enter the contact details of the device. Location Enter the location of the device. Community Name (Read Only) Enter the password for accessing the SNMP community for read-only access. Community Name (Read/Write) Enter the password for accessing the SNMP community for read and write access. Trap Destination Address Enter the IP address where SNMP traps are to be sent. Trap Destination Community Name Enter the password of the SNMP trap community. SNMPv3 Enable or Disable the SNMPv3 feature. User Name Specify the username for SNMPv3. Auth Protocol Select the authentication protocol type: MD5 or SHA. Auth Key (8-32 Characters) Specify the authentication key for authentication. Priv Protocol Select the privacy protocol type: DES. Priv Key (8-32 Characters) Specify the privacy key for privacy. 4-42 BASIC NETWORK SETTINGS CONFIGURING SNMP Engine ID Specify the engine ID for SNMPv3. Click Save/Apply to apply the changes or Cancel to return previous settings. 4-43 BASIC NETWORK SETTINGS CONFIGURING BACKUP/RESTORE SETTINGS 4.5.4 Configuring Backup/Restore Settings Click the Backup/Restore Setting link under the Management menu to save the EnStation2s current settings in a file on your local disk or load settings onto the device from a local disk. This feature is particularly convenient administrators who have several EnStation2 devices that need to be configured with the same settings. This page also lets you return the EnStation2 to its factory default settings. If you perform this procedure, any changes made to the EnStation2 default settings will be lost. Save A Copy of Current Settings Click Backup to save the current configured settings. Restore Saved Settings from A File To restore settings that have been previously backed up, click Browse, select the file, and click Restore. Revert to Factory Default Settings Click Factory Default to restore the EnStation2 to its factory default settings. 4-44 BASIC NETWORK SETTINGS CONFIGURING AUTO REBOOT SETTINGS 4.5.5 Configuring Auto Reboot Settings Click the Auto Reboot Settings link under the Management menu to enable or disable the Auto Reboot funciton. This feature is par-
ticularly convenient to administrators for the scheduling of auto rebooting on the device. This page also allows you to set the frequency of this function. Auto Reboot Setting Select Enable from the drop-down menu to setup this function. Frequency of Auto Reboot Select the frequency interval using the drop-down menus. Save/Apply Click Save/Apply to set the new configuration. Cancel Click Cancel to delete the settings. 4-45 BASIC NETWORK SETTINGS CONFIGURING FIRMWARE UPGRADE 4.5.6 Configuring Firmware Upgrade Firmware is system software that operates and allows the administrator to interact with the router.
WARNING!
Upgrading firmware through a wireless connection is not recommended. Firmware upgrading must be performed while connected to an Ethernet (LAN port) with all other clients disconnected. The firmware upgrade procedure can take several minutes. Do not power off the EnStation2 during the firmware upgrade, as it can cause the device to crash or become unusable. To update the firmware version, follow these steps:
1. Download the appropriate firmware approved by EnGenius Networks from an approved web site. Note:
Save the firmware file to a local hard drive. 2. Click Choose File. 3. Browse the file system and select the firmware file. 4. Click Upload. 5. The EnStation2 restarts automatically after the upgrade completes. 4-46 BASIC NETWORK SETTINGS CONFIGURING SYSTEM TIME 4.5.7 Configuring System Time Change the system time of the EnStation2 by manually entering the information, synchronizing the device with a PC, or setup auto-
matic updates through a network time (NTP) protocol server. Manually Set Date and Time Enter the date and time values in the date and time fields or click the Synchronize with PC button to get the date and time values from the administrators PC. Automatically Get Date and Time Select a time zone from the drop-down list and check whether you want to enter the IP address of an NTP server or use the default NTP server. Enable Daylight Saving Click to enable or disable daylight savings time. Select the start and stop times from the Start Time and Stop Time dropdown lists. Click Save/Apply to apply the changes or Cancel to return previous settings. 4-47 BASIC NETWORK SETTINGS CONFIGURING WI-FI SCHEDULE 4.5.8 Configuring Wi-Fi Schedule Use the Wi-Fi schedule function to control the wireless power ON/OFF service that operates on a routine basis. Add a Schedule Service Create a schedule service type and date/time parameters for a specific service. Schedule Name Enter the description of the schedule service. Service Select the type of schedule service, either Wireless Power ON or Wireless Power OFF. Day Select the days of the week to enable the schedule service. Time of Day Set the start time that the service is active. Click Add to append the schedule service to the sched-
ule service table, or Cancel to discard changes. 4-48 BASIC NETWORK SETTINGS SCHEDULE SERVICES TABLE Schedule Services Table The Schedule function relies on the GMT time setting acquired from a network time protocol (NTP) server. For details on how to con-
nect the EnStation2 to an NTP server, see Configuring System Time. Schedule Table Displays a list of scheduled services for the EnStation2. The properties of each service displayed are:
# Displays the ID number of the service in the table. Name Displays the description of the service. Service Displays the type of service, either Wireless Power ON or Wireless Power OFF. Schedule Displays the schedule information of when the service is active. Select Select one or more services to edit or delete. Click Delete Selected to delete the selected services or Delete All to delete all services. Click Apply to save the settings or Cancel to discard changes. 4-49 BASIC NETWORK SETTINGS CONFIGURING COMMAND LINE INTERFACE 4.5.9 Configuring Command Line Interface Most users will configure the EnStation2 through the graphical user interface (GUI). However, for those who prefer an alternative method there is the command line interface (CLI). The CLI can be access through a command console, modem or Telnet connec-
tion. CLI Select to enable or disable the ability to modify the EnStation2 via a command line interface (CLI). Click Save/Apply to apply the changes or Cancel to return previous settings. 4-50 BASIC NETWORK SETTINGS CONFIGURING LOGGING 4.5.10 Configuring Logging Display a list of events that are triggered on the EnStation2 Ethernet and wireless interfaces. You can consult this log if an unknown error occurs on the system or when a report needs to be sent to the technical support department for debugging purposes. Syslog Enable or disable the EnStation2 syslog function. Log Server IP Address Enter the IP address of the log server. Local Log Enable or disable the local log service. Click Save/Apply to apply the changes or Cancel to return previous settings. 4-51 BASIC NETWORK SETTINGS CONFIGURING DIAGNOSTICS 4.5.11 Configuring Diagnostics The diagnosis feature allow the administrator to verify that another device is available on the network and is accepting request pack-
ets. If the ping result returns alive, it means a device is on line. This feature does not work if the target device is behind a firewall or has security software installed. Target IP / Domain Name Enter the IP address you would like to search. Ping Packet Size Enter the packet size of each ping. Number of Pings Enter the number of times you want to ping. Start Ping Click Start Ping to begin pinging. Trace route target Enter an IP address or domain name you want to trace. Start Traceroute Click Start Traceroute to begin the traceroute operation. Target Address Enter the IP address of the target PC. Time period Enter time period for the speed test. Check Interval Enter the interval for the speed test. Start Speed Test Click Start Speed Test to begin the speed test operation. IPv4 Port Displays the IPv4 port number of the EnStation2. IPv6 Port Displays the IPv6 port number of the EnStation2. 4-52 BASIC NETWORK SETTINGS VIEWING DEVICE DISCOVERY 4.5.12 Viewing Device Discovery Device Name Displays the name of the devices connected to the network. Operation Mode Displays the operation mode of the devices connected to the network. IP Address Displays the IP address of the devices connected to the network. System MAC Address Displays the system MAC address of the devices connected to the network. Firmware Version Displays the firmware version of the devices connected to the network. 4-53 BASIC NETWORK SETTINGS CONFIGURE DENIAL OF SERVICE PROTECTION 4.5.13 Configure Denial of Service Protection Use TCP SYN Cookies Protection Click to enable TCP SYN cookies protection. SYN Flood Attack Protection Click to enable or disable SYN Flood Attack Protection. Match Interval Per Second Enter the allowed number of packets per second. Limit Packets Enter the maximum number of packets allowed per request. UDP Flood Attack Protection Click to enable or disable UDP Flood Attack Protection. Match Interval Per Second Enter the allowed number of packets per second. Limit Packets Enter the maximum number of packets allowed per request. Ping Attack Protection Click to enable or disable ping attack protection. Click Save/Apply to apply the changes or Cancel to return previous settings. 4-54 BASIC NETWORK SETTINGS 4.5.14 Logging Out Click Logout to logout from the EnStation2. LOGGING OUT 4-55 APPENDIX A Appendix A FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause unde-
sired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a partic-
ular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turn-
ing the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. A-1 APPENDIX A FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 24cm between the radiator & your body. A-2 APPENDIX B Appendix B EUROPE EU DECLARATION OF CONFORMITY Europe EU Declaration of Conformity This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R&TTE Directive 1999/5/EC:
EN60950-1 Safety of Information Technology Equipment EN50385 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz) EN 300 328 Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equip-
ment operating in the 2,4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive EN 301 489-1 Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements EN 301 489-17 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment B-1 APPENDIX B EUROPE EU DECLARATION OF CONFORMITY esky
[Czech]
Dansk
[Danish]
Deutsch
[German]
Eesti
[Estonian]
English Espaol
[Spanish]
[Greek]
Franais
[French]
Italiano
[Italian]
Latviski
[Latvian]
[Jmno vrobce] tmto prohlauje, e tento [typ zazen] je ve shod se zkladnmi poadavky a dalmi pslunmi ustanovenmi smrnice 1999/5/ES. Undertegnede [fabrikantens navn] erklrer herved, at flgende udstyr [udstyrets typebetegnelse]
overholder de vsentlige krav og vrige relevante krav i direktiv 1999/5/EF. Hiermit erklrt [Name des Herstellers], dass sich das Gert [Gertetyp] in bereinstimmung mit den grundlegenden Anforderungen und den brigen einschlgigen Bestimmungen der Richtlinie 1999/5/EG befindet. Kesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tp = type of equipment]
vastavust direktiivi 1999/5/E phinuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele stetele. Hereby, [name of manufacturer], declares that this [type of equipment] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
[name of manufacturer] [type of equipment]
1999/5/. Par la prsente [nom du fabricant] dclare que l'appareil [type d'appareil] est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Ar o [name of manufacturer / izgatavotja nosaukums] deklar, ka [type of equipment / iekrtas tips]
atbilst Direktvas 1999/5/EK btiskajm prasbm un citiem ar to saisttajiem noteikumiem. B-2 APPENDIX B EUROPE EU DECLARATION OF CONFORMITY Lietuvi
[Lithuanian]
Nederlands
[Dutch]
Malti
[Maltese]
Magyar
[Hungarian]
Polski
[Polish]
Portugus
[Portuguese]
Slovensko
[Slovenian]
Slovensky
[Slovak]
Suomi
[Finnish]
Svenska
[Swedish]
iuo [manufacturer name] deklaruoja, kad is [equipment type] atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming is met de essentile eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma mal-tiijiet essenzjali u ma provvedimenti orajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Alulrott, [gyrt neve] nyilatkozom, hogy a [... tpus] megfelel a vonatkoz alapvet kvetelmnyeknek s az 1999/5/EC irnyelv egyb elrsainak. Niniejszym [nazwa producenta] owiadcza, e [nazwa wyrobu] jest zgodny z zasadniczymi wymogami oraz pozostaymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
[Nome do fabricante] declara que este [tipo de equipamento] est conforme com os requisitos essenciais e outras disposies da Directiva 1999/5/CE.
[Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi relevantnimi doloili direktive 1999/5/ES.
[Meno vrobcu] tmto vyhlasuje, e [typ zariadenia] spa zkladn poiadavky a vetky prslun ustanovenia Smernice 1999/5/ES.
[Valmistaja = manufacturer] vakuuttaa tten ett [type of equipment = laitteen tyyppimerkint]
tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen. Hrmed intygar [fretag] att denna [utrustningstyp] str I verensstmmelse med de vsentliga egenskapskrav och vriga relevanta bestmmelser som framgr av direktiv 1999/5/EG. B-3 APPENDIX C Appendix C WorldWide Technical Support WORLDWIDE TECHNICAL SUPPORT REGION/COUNTRY OF PURCHASE SERVICE CENTRE CANADA web site email contact numbers hours of operation SERVICE INFORMATION www.engeniuscanada.com rma@engeniuscanada.com Toll Free: (+1) 888-397-2788 Local: (+1) 905-940-8181 Monday - Friday 9:00AM to 5:30PM EST (GMT-5) LOS ANGELES, USA web site www.engeniustech.com email contact numbers hours of operation support@engeniustech.com Toll Free: (+1) 888-735-7888 Local: (+1) 714-432-8668 Monday - Friday 8:00 AM to 4:30 PM PST (GMT-8) Canada USA C-1 APPENDIX C WORLDWIDE TECHNICAL SUPPORT REGION/COUNTRY OF PURCHASE SERVICE CENTRE MIAMI, USA Mexico, Central and Southern America NETHERLANDS DUBAI, UAE Europe Africa Middle East Russia CIS / Armenia, Azerbaijan, Belarus, Georgia, Kazakhstan, Kyrgyzstan, Moldova, Tajikistan, Turkmenistan, Ukraine, Uzbekistan Turkey Afghanistan Pakistan Bangladesh, Maldives, Nepal, Bhutan, Sri Lanka web site email contact numbers hours of operation web site email SERVICE INFORMATION
[ES] es.engeniustech.com
[PT] pg.engeniustech.com miamisupport@engeniustech.com Miami: (+1) 305-887-7378 Sao Paulo, Brazil: (+55)11-3957-0303 D.F., Mexico:(+52)55-1163-8894 Monday - Friday 8:00 AM to 5:30PM EST (GMT-5) www.engeniusnetworks.eu support@engeniusnetworks.eu contact numbers
(+31) 40-8200-887 hours of operation web site email contact numbers Monday - Friday 9:00 AM - 5:00 PM (GMT+1) www.engenius-me.com support@engenius-me.com Toll Free:
U.A.E.: 800-EnGenius 800-364-364-87 General:
(+971) 4357-5599 hours of operation Sunday - Thursday 9:00 AM - 6:00 PM (GMT+4) C-2 APPENDIX C WORLDWIDE TECHNICAL SUPPORT REGION/COUNTRY OF PURCHASE SERVICE CENTRE SERVICE INFORMATION Singapore, Cambodia, Indonesia, Malaysia, Thailand, Philippines, Vietnam China, Hong Kong, Korea India South Africa Oceania Others SINGAPORE TAIWAN, R.O.C. web site email contact numbers hours of operation web site email www.engeniustech.com.sg/e_warranty_form techsupport@engeniustech.com.sg Toll Free:
Singapore: 1800-364-3648 Monday - Friday 9:00 AM - 6:00 PM (GMT+8) www.engeniusnetworks.com technology@senao.com Note:
* Service hours are based on the local time of the service center.
* Please visit the website for the latest information about customer service. C-3
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2014-09-04 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2014-09-04
|
||||
1 | Applicant's complete, legal business name |
EnGenius Technologies
|
||||
1 | FCC Registration Number (FRN) |
0021371836
|
||||
1 | Physical Address |
1580 Scenic Avenue
|
||||
1 |
Costa Mesa, California 92626
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@curtis-straus.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
A8J
|
||||
1 | Equipment Product Code |
ENSTA2
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M****** L****
|
||||
1 | Title |
General Manager
|
||||
1 | Telephone Number |
888.7******** Extension:
|
||||
1 | Fax Number |
714.4********
|
||||
1 |
m******@engeniustech.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 2.4GHz b/g/n N300 CPE | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is the maximum combined conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 24 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation in accordance with FCC multi-transmitter product guidelines. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch
|
||||
1 | Name |
R**** C********
|
||||
1 | Telephone Number |
+886-******** Extension:
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
r******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | MO | 2412.00000000 | 2462.00000000 | 0.2940000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC