Fluidmesh 1100/1200VOLO/3100 MITO series User manual Firmware Version 6.0. Fluidmesh 1100/1200VOLO/3100 MITO Series Copyright 2005-2013 Fluidmesh Networks LLC. WARNING ONLY QUALIFIED PERSONNEL SHOULD INSTALL THIS UNIT. THE IN-
STALLATION SHOULD CONFORM TO ALL LOCAL CODES. IN SOME COUNTRIES, A CERTIFIED ELECTRICIAN MAY BE REQUIRED. CAUTION When open, the apparatus should not be dripping or splashing. No object lled with liquid shall be placed on the apparatus. NOTICE TO USERS Copyright Fluidmesh Networks LLC. All rights reserved. This manual or the software described herein, in whole or in part, shall not be reproduced, translated or reduced to any machine-readable form without prior written approval from Fluidmesh Networks LLC. FLUIDMESH NETWORKS LLC, PROVIDES NO WARRANTY WITH RE-
GARD TO THIS MANUAL, THE SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DISCLAIMS ANY IM-
PLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL, THE SOFT-
WARE OR SUCH OTHER INFORMATION. IN NO EVENT SHALL FLU-
IDMESH NETWORKS, INC. BE LIABLE FOR ANY INCIDENTAL, CON-
SEQUENTIAL OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THIS MANUAL, THE SOFTWARE OR OTHER INFORMATION CON-
TAINED HEREIN OR THE USE THEREOF. Fluidmesh Networks LLC, reserves the right to make any modification to this manual or the information contained herein at any time without notice. The software described herein may also be governed by the terms of a separate user license agreement. Fluidmesh is a registered trademark of Fluidmesh Networks LLC, Mesh-
Wizard, EasyMesh, FMQuadro, FluidThrottle, Endo, MITO are trademarks of Fluidmesh Networks, Inc. Microsoft, Windows, Internet Explorer are registered trademarks of Mi-
crosoft Corporation in the United States and/or other countries. 1 Ethernet is a registered trademark of Xerox Corporation. All other brands and product names are trademarks or registered trade-
marks of their respective owners. 2 Contents 1 Manual Overview 2 Precautions 3 Installation and System Set-up 3.1 Fluidmesh 1100 MITO Series . . . 6 7
. 8 8 9 9 10
. 10 11
. 12
. 13
. 13 14
. 14 15
. . . . 3.1.1 Proper Installation Procedures . . 3.1.2 Powering on an FM1100 . . 3.1.3 Status and Link LEDs . . 3.1.4 Factory Default Hardware Reset 3.1.5 Integrated Panel Antenna . . . . . . . . . . . 3.2 Fluidmesh 3100 MITO Series . . 3.2.1 Proper Installation Procedures . . 3.2.2 Powering on an FM3100 . . 3.2.3 Status and Link LEDs . . 3.2.4 Factory Default Hardware Reset 3.2.5 Integrated Panel Antenna . . . . . . . . . . . . . . 3.3 Fluidmesh 1200VOLO .. . . . . . . . . . . . . . . . . . . 16 3.3.1 Proper Installation Procedures . . . . . . . . . . . . . 17 3.3.2 Powering on an 1200 VOLO. . .. . . . . . . . . . . . . 17 3.3.3 Status and Link LEDs . . . . . . . . . . . . . . . . . . 18 3.3.4 Factory Default Hardware Reset . . . . . . . . . . . . 18 Integrated Panel Antenna . . . . . . . . . . . . . . . . 19 3.3.5 4 Fluidmesh Architecture Overview 4.1 Point-to-Point Wireless Bridge . . 4.2 Mesh Network Architecture . . 4.3 Point-to-Multipoint Architecture: FluidMAX . . . . . . 20 20
. 21 22 3 5 Fluidmesh Network Addressing 5.1 Bridge IP Addressing . . 24 24 5.1.1 Connecting and Conguring IP Devices and Cameras 25 25
. 26 5.2.1 Network Addressing . . . . . . . . . . 5.2 Mesh Addressing . . 6 Software Plug-ins 6.1 Plug-in Activation/Deactivation Procedure . . 29
. 30 7 Web-based Interface and Conguration
. . . . . 33
. 33 7.1 Software and Hardware Requirements . . 34 7.2 Logging-in to the Web-based Interface . . 7.3 End-user License Agreement and Region of Operation . 35 7.4 MeshWizard . . 37
. 37 7.5 Web-based Interface Menus . . 7.6 General Mode . . 38
. 38 7.7 Wireless Settings . . 42 7.8 Advanced Wireless Settings . . 7.9 Antenna Alignment Tools and Physical Statistics . . 43
. 45 7.10 Frequency Scan Tool . . 47 7.11 FMQuadro (Mesh End only)
. . . . . . . . . . . . . . . . . . . . . . . . quired) . . . . . . . . . . . . 7.11.1 VLAN Tagging Conguration (Software Plug-in Re-
. . 53
. 54 7.12 Firmware Upgrade . . 56 7.13 Plug-in Management . . 57 7.14 Advanced Tools . . . 7.15 Multicast . . 58
. . 7.16 PoE Passthrough (FM1100 and FM1200 only) . . . . . . . . . 59 7.17 Change Password . . 59
. 59
. . . 7.18 Status . . 60 7.19 Reboot and Reset to Factory Default . . 7.20 On-line Help . . . . 60
. . . . . . . . . . . . . . . . . . . . . . . . . . 4 8 Troubleshooting 8.1 I am unable to get the log-in screen . . 8.2 I am unable to log-in into the Web-based interface . . 8.3 I forgot the administrator password . . . 8.4 In Bridge Mode I get no Link or the Link LED is always red or
. . . 61
. 61
. 61
. 62 I am getting a weak Wireless link (below 60% signal strength) 62 5 1 Manual Overview This manual describes how to install and operate the Fluidmesh VOLO and MITO series products. More specifically, this manual contains a general overview of the Fluidmesh 1100 MITO, Fluidmesh 1200 VOLO and the Fluidmesh 3100 MITO in Section 3.1, Section 3.2 and Section 3.3 respectively. Please refer to Fig. 1.1(a), Fig. 1.1(b) and Fig.1.1(c) for a representation of each product. This users manual also includes a complete overview of the network architectures that can be created using Fluidmesh technology, and is discussed in Section 4. The Fluidmesh net-
work addressing is described in Section 5. The use of Fluidmesh software plug-ins, their features, and their installation procedures in a network fol-
lows in Section 6. The Web-based Graphical User Interface (GUI) is then described in Section 7. Please note that, unless otherwise explicitly speci-
fied, the Web GUI presentation refers to the Fluidmesh 1100, Fluidemesh 1200 and the Fluidmesh 3100. Screenshots shown in this manual are explanatory examples and may be different from the ones that appear when you run the Web-based configuration software.
(a) Fluidmesh 1100 MITO (b) Fluidmesh 3100 MITO
(c) Fluidmesh 1200 VOLO Figure 1.1: Fluidmesh 1100 MITO, Fluidmesh 1200 VOLO and Fluidmesh 3100 MITO front view. 6 2 Precautions Fluidmesh Networks products are for professional use only. Fluidmesh Networks products have been designed with safety in mind. However, if not used properly, they can cause fires which may lead to serious bodily injuries. To avoid such accidents, make sure that you are properly qualified to install these products. In Case of Breakdown In case of system breakdown, discontinue use and immediately contact your authorized Fluidmesh Networks dealer or Fluidmesh Networks LLC. directly. In Case of Abnormal Operations If the unit emits smoke or an unusual smell, if water or other foreign mat-
ter enters the enclosure, or if your drop the unit or damage the enclosure, power off the unit immediately and contact your authorized Fluidmesh Net-
works dealer or Fluidmesh Networks LLC directly. 7 3 Installation and System Set-up This section describes how to install and set up Fluidmesh products. Specif-
ically, the Fluidmesh 1100 MITO, Fluidmesh 1200 VOLO and Fluidmesh 3100 MITO series are described in Section 3.1, Section 3.2 and Section 3.3 respectively. 3.1 Fluidmesh 1100 MITO Series The Fluidmesh 1100 MITO (part number FM1100M-HW, for simplicity re-
ferred to as FM1100) is designed for wireless operations . The hardware is multi-band panel an-tenna which can be mounted and oriented using the supplied pole-mounting adapter as depicted in Fig. 3.1 and Fig. 3.2 Figure 3.1: Fluidmesh 1100 enclosure (back). The FM1100 can operate both as a point-to-point wireless bridge or as a single radio mesh unit. The former operating mode is described in Sec-
tion 4.1 whereas the latter is discussed in Section 4.2. 8 Figure 3.2: Fluidmesh 1100 pole mounting adapter, Ethernet ports and reset button. 3.1.1 Proper Installation Procedures The FM1100 comes with a pole-mounting adapter, shown in Fig. 3.2, that allows the installer to change the alignment of the antenna along the hor-
izontal axis. Plastic or metal tie wraps can be used to install the unit on a pole. 3.1.2 Powering on an FM1100 The unit can be powered only with the Power-over-Ethernet injector pro-
vided with the FM1100 (Fig. 3.3). The PoE injector does not comply with the 802.3af standard and therefore it cannot be substituted with a different injector. Figure 3.3: Fluidmesh 1100 Power-over-Ethernet injector. The PoE injector must be powered 100-240V 50-60Hz AC using the AC 9 LED # (Color) 1 (Red) 2 (Orange) 3 (Green) 4 (Green) Boot Status Booting core system Booting wireless system Booting routing engine Booting unit conguration Link Quality poor/link absent fair good very good Table 3.1: FM1100 Boot/Link Status LEDs Color Scheme adapter included. 3.1.3 Status and Link LEDs A panel on the back of the FM1100, shown in Fig. 3.4, provides seven
(7) LEDs which can be used to check the unit and the link quality status. From the left-hand side, the rst 3 green LEDs indicate the unit power, the Ethernet port #1 activity and the Ethernet port #2 activity, respectively. The remaining 4 colored LEDs indicate the level of the link signal and can be used for antenna alignment purposes. During the unit boot-up process, the 4 colored LEDs indicate the boot status and can be used for problem detection. In fact, the LEDs light up in sequence from the leftmost one (red) to rightmost one (bright green). If the LEDs lighting up sequence does not complete, then an error has been detected during the booting process. Please refer to Table 3.1 for details. Figure 3.4: From left to right status LEDs, link/boot LEDs. 3.1.4 Factory Default Hardware Reset The FM1100 can be reset to factory default using the RESET button placed nearby the Ethernet ports as shown in Fig. 3.2. To reset the FM1100 to factory default settings, power up the unit and wait approximately 40 sec-
onds for the unit to boot up. Once the unit is up and running, press the reset button for 5 seconds. The FM1100 will restore the factory default set-
tings and automatically reboot. After the reset, the default IP address of 192.168.0.10/255.255.255.0 is restored and the administrator password is set to admin. The RESET button can also be used to reboot the unit when pressed for 1 second. 10 3.1.5 Integrated Panel Antenna The FM1100 has an integrated panel antenna that can operate at 4.9-6.0 GHz. A separate or external antenna cannot be installed or mounted. The gain of the antenna is 15 dBi at 4.9-6.0 GHz. The specications of the integrated panel antenna are reported Table 3.2. Gain at 4.9-6.0 GHz Frequency Range Polarization 3 dB Beam Angle @ 5470 MHz Front to Back Ratio 14.6-16.1 dBi 4940-6075 MHz Dual Linear 43 degrees 22 dB Table 3.2: Antenna Specications 11 3.2 Fluidmesh 3100 MITO Series The Fluidmesh 3100 MITO (part number FM3100M-HW, for simplicity re-
ferred to as FM3100) is designed for wireless operations. The hardware is multi-band sector antenna which can be mounted and oriented using the supplied pole-mounting adapter as depicted in Fig. 3.5 and Fig. 3.6. Figure 3.5: Fluidmesh 3100 enclosure. The FM3100 can operate both as a point-to-point wireless bridge or as a single radio mesh unit . The former operating mode is described in Sec-
tion 4.1 whereas the latter is discussed in Section 4.2. 12 Figure 3.6: Fluidmesh 3100 pole mounting adapter. 3.2.1 Proper Installation Procedures The FM3100 comes with a pole-mounting adapter, shown in Fig. 3.6, that allows the installer to change the alignment of the antenna along both the vertical and the horizontal axis. 3.2.2 Powering on an FM3100 The unit can be powered only with the Power-over-Ethernet injector pro-
vided with the FM3100 (Fig. 3.7). The PoE injector does not comply with the 802.3af standard and therefore it cannot be substituted with a different injector. Figure 3.7: Fluidmesh 3100 Power-over-Ethernet injector. The PoE injector must be powered 100-240V 50-60Hz AC using the AC adapter included. 13 LED # (Color) 1 (Red) 2 (Orange) 3 (Green) 4 (Green) Boot Status Booting core system Booting wireless system Booting routing engine Booting unit conguration Link Quality poor/link absent fair good very good Table 3.3: FM3100 Boot/Link Status LEDs Color Scheme 3.2.3 Status and Link LEDs A panel on the back of the FM3100, shown in Fig. 3.8, provides six (6) LEDs which can be used to check the unit and the link quality status. From the left-hand side, the rst 2 green LEDs indicate the unit power, the Ethernet port activity, respectively. The remaining 4 colored LEDs indicate the level of the link signal and can be used for antenna alignment purposes. During the unit boot-up process, the LEDs indicate the boot status and can be used for problem detection. Specically, the 4 colored LEDs light up in sequence from the leftmost one (red) to rightmost one (bright green). If the LEDs lighting up sequence does not complete, then an error has been detected during the booting process. Please refer to Table 3.3 for details. Figure 3.8: From left to right status LEDs, link/boot LEDs. 3.2.4 Factory Default Hardware Reset The FM3100 can be reset to factory default using the proper RESET button present on the PoE injector provided with the unit as shown in Fig. 3.7. To reset the FM3100 to factory default settings, power up the unit and wait approximately 40 seconds for the unit to boot up. Once the unit is up and running, press the reset button for 5 seconds. The FM3100 will restore the factory default settings and automatically reboot. The LEDs will blink when the unit receives the reset to factory default signal. After the reset, the default IP address of 192.168.0.10/255.255.255.0 is restored and the administrator password is set to admin. The RESET button can also be used to reboot the unit when pressed for 1 second. 14 3.2.5 Integrated Panel Antenna The FM3100 has an integrated 93 degrees sector antenna that can oper-
ate at 4.9-6.0 GHz. A separate or external antenna cannot be installed or mounted. The gain of the antenna is 15 dBi at 4.9-6.0 GHz. The specica-
tions of the integrated panel antenna are reported Table 3.4. Gain at 4.9-6.0 GHz Frequency Range Polarization 3 dB Beam Angle @ 5470 MHz Front to Back Ratio 15 dBi 4940-6075 MHz Dual Linear 93 degrees 22 dB Table 3.4: Antenna Specications 15 3.3 Fluidmesh 1200 VOLO The Fluidmesh 1200 VOLO(part number FM1200V-HW, for simplicity re-
ferred to as FM1200) is designed for wireless operations. The hardware is multi-band sector antenna which can be mounted and oriented using the supplied pole-mounting adapter as depicted in Fig. 3.9 and Fig. 3.10. Figure 3.9: Fluidmesh 1200 enclosure. The FM1200 can operate both as a point-to-point wireless bridge or as a single radio mesh unit. The former operating mode is described in Sec-tion 4.1 whereas the latter is discussed in Section 4.2. 16 LED # (Color) 1 (Red) 2 (Orange) 3 (Green) 4 (Green) Boot Status Booting core system Booting wireless system Booting routing engine Booting unit conguration very good Link Quality poor/link absent fair good Table 3.5: FM1200 Boot/Link Status LEDs Color Scheme 3.3.3 Status and Link LEDs A panel on the side of the FM1200, shown in Fig. 3.12, provides six (6) LEDs which can be used to check the unit and the link quality status. From the buttom up, the first 2 green LEDs indicate the unit power, the Ethernet port activity, respectively. The remaining 4 colored LEDs indicate the level of the link signal and can be used for antenna alignment purposes. During the unit boot-up process, the LEDs indicate the boot status and can be used for problem detection. Specifically, the 4 colored LEDs light up in sequence from the leftmost one (red) to rightmost one (bright green). If the LEDs lighting up sequence does not complete, then an error has been detected during the booting process. Please refer to Table 3.5 for details. Figure 3.12: From buttom up status LEDs, link/boot LEDs. 3.3.4 Factory Default Hardware Reset The FM1200 can be reset to factory default using the proper RESET button present on the PoE injector provided with the unit as shown in Fig. 3.11. To reset the FM1200 to factory default settings, power up the unit and wait approximately 40 seconds for the unit to boot up. Once the unit is up and running, press the reset button for 5 seconds. The FM1200 will restore the factory default settings and automatically reboot. The LEDs will blink when the unit receives the reset to factory default signal. After the reset, the default IP address of 192.168.0.10/255.255.255.0 is restored and the administrator password is set to admin. The RESET button can also be used to reboot the unit when pressed for 1 second. 18 Integrated Panel Antenna 3.3.5 The FM1200 has an integrated 93 degrees sector antenna that can oper-
ate at 4.9-6.0 GHz. A separate or external antenna cannot be installed or mounted. The gain of the antenna is 15 dBi at 4.9-6.0 GHz. The specifica-
tions of the integrated panel antenna are reported Table 3.4. Gain at 4.9-6.0 GHz Frequency Range Polarization 3 dB Beam Angle @5470 MHz Front to Back Ratio 15 dBi 4940-6075 MHz Dual Linear 93 degrees 22 dB Table 3.6: Antenna Specifications 19 4 Fluidmesh Architecture Overview The FM1100, FM1200 and the FM3100 series can be used to create any kind of network architecture such as point-to-point links and mesh networks. More-over, thanks to the innovative FluidMAX patent pending technology, point-to-multipoint links can be created. This also gives to the user the ability to create mixed networks architectures leading to higher performance and flexibility in the deployment. In the following section we describe how to build point-to-point, point-to- multipoint, and mesh networks with the Fluidmesh products. 4.1 Point-to-Point Wireless Bridge A wireless bridge enables two local networks (i.e., network segments) to communicate with each other . The wireless bridge 20 is dened as transparent because its activity is transparent to the network hosts. In other words, the wireless bridge forwards packets from one net-
work segment to the other according to a forwarding table which is built by learning the network topology from the analysis of the incoming trafc. In this conguration, no explicit interaction between the wireless bridge and the network hosts takes place. The two network segments, connected to both sides of the wireless bridge, will share the same IP addressing class. Thus, each network host must use a unique IP address, i.e., it is not allowed to have two devices sharing the same IP address. 4.2 Mesh Network Architecture This section describes the Fluidmesh mesh networking architecture and the basic functionalities of the FM1100/FM1200/FM3100 series. For the sake of clarity, we will refer to a generic FM unit whenever the discussion applies to the FM1100, FM1200 and the FM3100 series. Fluidmesh Networks develops wireless networking solutions based on the innovative mesh networking architecture which presents unmatched advan-
tages in terms of reliability and exibility compared to any traditional wire-
less solution. Using Fluidmesh technology for your network allows you to take advantage of this powerful architecture. An example of wireless mesh network is shown in Fig. 4.3. In a wireless mesh network, every FM unit transmits the data packets coming from the devices directly attached to it and also acts as an intelligent router able to forward packets coming from other FM units through the optimal path. 21 In a redundant and reliable mesh network, every stream of data packets has multiple available paths to reach the base station, and the network forwards the packets through the optimal path at any point in time. The absence of any single point of failure increases its reliability compared to any other transmission technology, either wireless or wired. 4.3 Point-to-Multipoint Architecture: FluidMAX Developing FluidMAX1, Fluidmesh embraced the Point-to-Multipoint archi-
tecture improving its features and capabilities to meet the needs of system integrators in the security and industrial automation indus-try. The FluidMAX technology is based on a centralized Medium Access Control (MAC) protocol and allows Fluidmesh customers to create point-to-
multipoint networks using the FM units. With the FluidMAX technology, an FM unit can thus be used at the center of the star topology in a point-to-multipoint fashion using sector antennas or antenna splitters with multiple directional antennas. The unit operating at the center of the star topology plays the role of Master and is in charge of coordinating communications to and from the other units which thus act as Slaves. As a result, the hidden and exposed terminal problems are eliminated by the centralized FluidMAX MAC protocol which supports up 1Patent pending. 22 to 100 Mb/s maximum throughput.2 By reducing the number of slaves, the supported rate per slave can be increased provided that the sum of the throughput requirements of the slaves is lower than or equal to 100 Mb/s. FluidMAX is fully automatic and integrated within the mesh architecture. By continuously monitoring the network topology, FM units are able to auto-
matically select whether to operate the FluidMAX MAC protocol or remain in the initial mesh operating mode. Consequently, no additional congura-
tion is needed to enable the FluidMAX features because the communica-
tion protocol is automatically chosen by the FluidMAX protocol based on the detected network topology. 2We assume the default channel width of 40 MHz. 23 5 Fluidmesh Network Addressing 5.1 Bridge IP Addressing The FM unit can be operated in bridge mode to create a single point-
to-point connection between two network segments as described in Sec-
tion 4.1. Each FM unit is provided with a default IP address for its wired Ethernet port(s), which is:
No IP address is associated to the wireless interface. 192.168.0.10 When you set up a wireless bridge using two FM units for the rst time, both units will have the same default IP address equal to 192.168.0.10. It is recommended to change the IP address of one of the two units in order to unambiguously address and congure the system with no confusion (see Fig. 5.1). Figure 5.1: Wireless network architecture and initial bridge conguration. 24 5.1.1 Connecting and Conguring IP Devices and Cameras The FM3100 mounts one Ethernet port and the FM1100 and FM1200 is equipped with 2 Ethernet ports that can be used to connect a camera or other Ethernet-compatible device. You should directly connect any device using an Ethernet cable to the PoE injector. Use a patch Ethernet cable to connect the PoE injector to the FM unit. FM1100 the second Ethernet port can be used to power any 12-18V passive PoE device. Therefore, multiple FM unit can be connected together in a daisy chain fashion if required. The camera or the device attached to the FM unit should use an IP address belonging to the same class of the devices on the other network segment of the wireless bridge. The default IP address class is 192.168.0.0/255.255.255.0. 5.2 Mesh Addressing The FM units have two modes of operation which are used to develop mesh network architectures:
Mesh Point Mode Mesh End Mode Mesh Point Mode: it is the default mode for the FM unit. Each unit in the eld that is not connected to the wired LAN backbone must be set in Mesh Point Mode. Mesh End Mode: in the Fluidmesh network, an FM unit that is connected to the main wired LAN must be set in Mesh End Mode. The Mesh End unit is the junction point between the wireless network and any IP-based wired network. Regardless of its conguration, any FM unit comes from the factory with a unique unit ID with the following format:
5.a.b.c where the triplet (a,b,c) unambiguously identies the unit and cannot be changed. The unit ID is used to identify the units throughout the Web-
based Graphical User Interface (GUI). 25 Figure 5.2: Fluidmesh network addressing. 5.2.1 Network Addressing The Fluidmesh layer 2 addressing allows configuring each FM unit and each device connected to the FM units according to the IP address class used within the private LAN to which the Mesh End unit is connected. A sample network configuration is shown in Fig. 5.2. The Fluidmesh network logically becomes part of the private LAN where
(usually) the control room resides. Therefore, both the FM units and any other edge device should be provided with a private LAN IP address and will be accessed through that specified IP address. Consider the example depicted in Fig. 5.2 where the private LAN IP ad-
dress class is 192.168.150.0 with netmask 255.255.255.0. Each device is configured with an IP address belonging to this class. Please note that each IP address must be univocal within the entire network to avoid ad-
dress conflicts. The default IP address of each FM unit is 192.168.0.10 with netmask 255.255.255.0. Finally, please note that the default factory-
set 5.a.b.c unit IDs are still valid and used to unambiguously identify each FM unit. Multiple FM units can be connected together through a network switch to form clusters of radios if needed. The Fluidmesh proprietary routing proto-
col will be run automatically on the cabled segment of the network. Please note that the units must be operated in Mesh Point mode only to activate the cluster feature. 26 Connecting and Conguring an Ethernet Edge-device The FM unit Ethernet ports can be used to connect all kinds of Ethernet edge devices (e.g. IP Cameras, Video-Servers, Wi-Fi Access Points, etc.). Any Ethernet device can be congured either manually or automatically through a DHCP server. A manual IP setting is recommended in any video-surveillance system where the cameras need to have a xed custom IP address to be accessed by the video-recording software. Figure 5.3: Network conguration with two port-based VLANs. VLAN Tagging (Software Plug-in Required) Virtual LAN (VLAN) tagging (or IEEE 802.1q) is a networking standard al-
lowing multiple switched networks to transparently share the same physical hardware without the leakage of information between networks. For exam-
ple, consider a company with several departments. With VLAN tagging, a separate private logical network is made available for each department while using only one physical corporate network. Each VLAN is identied by a specic number called VLAN ID (VID) which is also used for tagging packets belonging to the same VLAN. Because VLANs are based on logi-
cal instead of physical connections, several types of VLANs exist based on the criteria adopted to logically separate networks. The traditional VLAN scheme is port-based where each physical Ethernet port is congured specifying membership in a VLAN. However, if there are requirements that 27 individuals or devices must be segregated regardless of their physical lo-
cation, the MAC-based VLANs can be used. In this case, the network is congured with an access list mapping individual MAC addresses to VLAN membership. Other, less common, types of VLANs exist like the protocol-
based VLANs, where the protocol type is used to separate networks. VLAN tagging is usually supported by network switches with advanced capabilities. The wireless networks can be viewed as a large distributed switch with VLAN support. Two different types of VLAN tagging mecha-
nisms are supported: port-based and mac-based VLANs. Fig 5.3 reports a network conguration example where two VLANs are set up, i.e. using VID #2 and VID #3. Each VLAN uses a separate IP address class and the devices belonging to the VLANs must be congured accordingly. The Fluidmesh VLAN implementation is compatible with the specication of the IEEE 802.1q standard and, thus, the Fluidmesh network can interop-
erate with other VLAN-aware network devices. VLAN trunking between the Fluidmesh network and the Ethernet switches is also supported to enable carrying VLAN membership information throughout the wireless and wired network segments. The VLAN tagging can be enabled and congured through the Web inter-
face as described in Section 7.11.1. Multicast Streaming To enable multicast video-streams from IP cameras or video-encoders, no multicast group setting is required. Every multicast packet will be forwarded by the Mesh Point unit towards the closest Mesh End unit. Please refer to Section 7.15 for additional details. 28 6 Software Plug-ins the users needs. On The Fluidmesh 1100 MITO (part number FM1100M-HW), Fluidmesh 1200VOLO (part number FM1200V-HW) and the Fluidmesh 3100 MITO (part number FM3100M-HW) feature the innovative FluidThrot-tle technology which provides a variable software-upgradable capacity of the Ethernet port based on the Fluidmesh 1100 and Fluidemsh1200, the user can purchase software-based Plug-ins to increase the maximum capacity of the Ethernet port from 1 Mb/s to 100 Mb/s depending on the systems bandwidth requirements. On the Fluidmesh 3100, the user can purchase software-based Plug-ins to increase the maximum capacity of the Ethernet port from 10 Mb/s to 100 Mb/s depending on requirements. The FluidThrottle technology follows the cost-effective What You Need Is What You Get philosophy which provides the user with maximum flexibility in choosing (and paying for) what he/she exactly needs. FM1100M-HW and FM1200V-HW part numbers include the hardware and the default Ethernet Port Capacity of 1 Mb/s. FM3100M-HW part number includes the hardware and the default Ethernet Port Capacity of 10 Mb/s. the systems band-width FM1100 FM3100 Description Part Number FM1100M-02 Ethernet Capacity up to 2.5 Mb/s FM1100M-05 Ethernet Capacity up to 5 Mb/s FM1100M-10 Ethernet Capacity up to 10 Mb/s FM1100M-30 Ethernet Capacity up to 30 Mb/s FM1100M-60 Ethernet Capacity up to 60 Mb/s FM1100M-UN Ethernet Capacity up to 100 Mb/s FM3100M-30 Ethernet Capacity up to 30 Mb/s FM3100M-60 Ethernet Capacity up to 60 Mb/s FM3100M-UN Ethernet Capacity up to 100 Mb/s FM-AES FM-49 FM-LF 128-bit AES Encryption 4.9 GHz Band Licensed Frequencies Table 6.1: Software Plug-in upgrades. 29 the Serial Number are accepted) in order to get the Activation Code. Please refer to Section 7.13 to input the Activation Code into the unit Web interface. To provide the maximum exibility in the Plug-in management, Fluidmesh allows the deactivation of any installed Plug-in in order to transfer it to an-
other Fluidmesh unit. Specically, each Plug-in can be deactivated via the Web interface of the unit according to the procedure described in Sec-
tion 7.13. A Deactivation Code is provided by the unit which can be input in the Fluidmesh Plug-in Management Web Page on Fluidmesh Extranet to generate a fresh License Code as depicted in Fig. 6.2(b). The latter can then be used to generate a new Activation Code to activate the Plug-in for a different unit. 31
(a) Plug-in Activation
(b) Plug-in Deactivation Figure 6.2: Activation/Deactivation Code Generation Web interface avail-
able at www.uidmesh.com. 32 7 Web-based Interface and Conguration Every FM unit can be congured and managed using a Web-based Graph-
ical User Interface (GUI). By default, each FM unit is congured in Bridge Mode with the Bridge IP address 192.168.0.10 and netmask 255.255.255.0. To change the settings on the units, you need to log-in to the Web-based interface. 7.1 Software and Hardware Requirements To log-in to the Web GUI, you need a PC with a Web-browser, an Ethernet port, and an Ethernet cable. Requirements List:
Cat5 Crossover Ethernet cable with RJ45 connectors. PC with the following characteristics:
Windows XP or Windows 2000. In this manual, we assume use of Windows XP and every instruction or screenshot is based on this assumption. The device can also be congured using other operating systems, such as Linux, MAC OS, or older versions of Windows. Microsoft Internet Explorer 6. In this manual, we assume use of Microsoft Internet Explorer 6 or newer. A Fluidmesh device can also be congured using other browsers such as older ver-
sions of Internet Explorer, Firefox or Safari but the conguration using these browsers has not been thoroughly tested. Wired Ethernet Network Card. Hardware Requirements. Typical PC hardware allowing for proper operations of Windows XP and Microsoft Internet Ex-
plorer 6. 33 Figure 7.1: Log-in window. 7.2 Logging-in to the Web-based Interface Power up the device after making sure the antennas are properly con-
nected. Wait for about one minute for the initialization to be completed. Connect an Ethernet cable with RJ45 connectors between a computer and the Fluidmesh device that you want to congure. Congure the wired Ethernet port of your computer according to the de-
fault class C IP address of the device, e.g., IP: 192.168.0.30, Netmask:
255.255.255.0. If you do not know how to congure your Windows PC, please refer to Sec-
tion 8 where the manual IP conguration process is described. Disable the Access the Internet using a proxy server function. To disable this function, go to Control Panel > Internet Options > Connections > LAN Settings and uncheck the Enable box. Disable the wireless Wi-Fi card of your PC if present to avoid routing issues between the two network inter-
faces of your computer. Open a Web-browser such as Internet Explorer and type the following URL:
http://192.168.0.10 Make sure not to omit the initial http://. Some browsers might not work without the http:// prex preceding the numeric address. A log-in form asking for a username and a password should appear as shown in Fig. 7.1. To preserve the security of your system, make sure you change the default password once the entire installation is completed. In case the log-in form does not appear, please refer to Section 8. 34 The default username and a password are:
Username: admin Password: admin Figure 7.2: End-user license agreement. 7.3 End-user License Agreement and Region of Op-
eration The rst time you log-in, you will be asked to accept the terms of the end-
user license agreement and select the country where you will be operating the unit (Fig. 7.2 is an example for an FM1100 unit). You must accept the terms of the license agreement in order to activate the device. If you do not wish to accept the terms of the license agreement, please turn off the unit and contact Fluidmesh Networks. Choosing a wrong country/regulatory do-
main setting may lead to an illegal wireless conguration. Once the license is accepted, the unit can be congured. Two congu-
ration methods are available as shown in Fig. 7.3(a): MeshWizard and Classic. The former consists of a simple four step wizard to congure the basic settings of the unit (see Section 7.4), whereas the latter is the classic Fluidmesh Web-based GUI for advanced conguration (see Section 7.5). 35
(a) Step 1
(b) Step 2
(c) Step 3
(d) Step 4 Figure 7.3: MeshWizard FM unit conguration steps. 36 7.4 MeshWizard MeshWizard is a simple yet effective tool to congure the basic settings of an FM unit based on the following four steps:
1. Step 1, Fig. 7.3(a): click on the Wizard button to start conguring the unit;
2. Step 2, Fig. 7.3(b): unit IP conguration;
3. Step 3, Fig. 7.3(c): wireless radio frequencies conguration;
4. Step 4, Fig. 7.3(d): settings summary and conguration save. 7.5 Web-based Interface Menus Once logged in successfully, the general mode page will appear as shown in Fig. 7.4. Through this page you can change the mode of operation of the FM unit. The item list menu on the left can be used to set/modify the conguration of the unit. Figure 7.4: FM unit general conguration window. 37 7.6 General Mode Every FM unit has three possible modes of operations:
Bridge Mode Mesh Point Mode Mesh End Mode The FM unit factory default mode is Bridge. The Mesh Point mode must be used for any unit deployed in the eld. On the other hand, the FM unit must be set in Mesh End whenever it is connected to the main cabled network where the control room (usually) resides. You will need to input the settings of the wired network (LAN) to which the FM unit unit will be connected. The default IP address of the FM unit is 192.168.0.10 and the default Netmask is 255.255.255.0. If you do not know the LAN settings, contact the local network administrator before changing the settings of the gateway. Please remember that a Mesh End unit is always necessary for the correct mesh network operations, even for small networks (e.g., 2 FM units). 7.7 Wireless Settings The wireless settings menu is used to congure the radio present in the FM unit and can be accessed by clicking on wireless radio. The wire-
less settings menu is available in either Basic (Fig. 7.5) or Advanced mode
(Fig. 7.6). The former provides the basic radio conguration options whereas the latter can be enabled by expert users for tuning the radio channel width or using non-standard carriers. The following wireless parameters are avail-
able:
Shared Passphrase. The shared passphrase is a shared secret that must be set in every FM unit forming a wireless network. Any Fluidmesh device that does not have the correct passphrase will not be able to be part of the network. Different passphrases can also be used to create separate Flu-
idmesh networks in the same area and sharing the same frequencies. Country. You need to specify the country where you will operate the unit. Different countries have different telecommunications regulations. Setting the country properly allows you to operate in compliance with national reg-
ulations. The available frequencies and other settings related to the RF op-
eration will vary based on the selected country. Choosing the wrong coun-
try/regulatory domain may lead to an illegal operation of the unit. Please 38 Figure 7.5: Wireless parameters conguration. Basic mode make sure the country has been properly specied before changing the fre-
quency of the system. Frequency Selectors. All Fluidmesh units are equipped with multi-band radios capable of operating on the 4.9-6 GHz bands.1 You can change the frequency of each radio in order to minimize interference with other wire-
less networks operating in the same area. The frequencies listed on the Frequency Selector are the carrier frequencies. In Basic mode, each ra-
dio operates using xed channel carriers with 40 MHz channel widths as specied by the local country regulations. In Advanced mode, the user is allowed to select any channel carrier in the local country frequency band with a 5 MHz granularity. The channel width can be set through the specic selector (see below). Make sure you pick non-overlapping channels if you need to operate more than one unit in the same area. In Advanced mode, the following selectors are also available:
14.9 GHz and 6 GHz are licensed bands which must be enabled through the proper software plug-in. Please refer to Section 7.13 for details. 39 Figure 7.6: Wireless parameters conguration. Advanced mode Width Data Rate Throughput 20 MHz 40 MHz 150 Mb/s 300 Mb/s 60 Mb/s 100 Mb/s Table 7.1: Available radio channel widths. Channel Width. The width of the operating radio channel can be set through this selector. The available options are described in Table 7.1 where the theoretic data rate and the achievable throughput are also in-
dicated for each channel width. Whenever possible, setting the radio to operate on a narrower channel can be useful to reduce the interference in the network and to increase the num-
ber of available channels. Please remember to set the same channel width on both sides of the wireless link. A channel width mismatch will prevent the FM units from communicating properly. Please note that changing the channel width may violate the local telecommunication authorities guide-
40 lines and lead to illegal wireless operations. IN NO EVENT SHALL FLUIDMESH NETWORKS, INC. BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH IMPROPER USE OR OPERATION OF THE CHAN-
NEL WIDTH FUNCTIONALITIES. DFS Management. Each device implements a proprietary distributed chan-
nel switching algorithm which is used when a radar is detected to com-
ply with the Dynamic Frequency Selection (DFS) international regulations. Upon radar detection, two communicating Fluidmesh units agree to switch to the next radar-free channel so that they can continue to communicate on that channel. The DFS is automatically enabled in the following frequency ranges: 5.250 GHz 5.350 GHz and 5.470 GHz 5.725 GHz. The DFS management can be manually disabled. The number of detected radars is reported as well. Outside these mandatory frequency bands, the DFS is not required and it is disabled by default. Please note the DFS is required by law in many countries and by disabling it you might incur nes and crim-
inal charges by the local telecommunication authorities. IN NO EVENT SHALL FLUIDMESH NETWORKS, INC. BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH IMPROPER USE OR OPERATION OF THE DFS FUNCTIONALITIES. 41 Option AUTO Specication The FluidMAX engine is enabled and the unit role is set automatically. MASTER The FluidMAX engine is enabled and the unit role is set to MASTER. This is used to force the FluidMAX role of the Fluidmesh unit at the center of the star topology to be a MASTER. The FluidMAX engine is enabled and the unit role is set to SLAVE. This is used to force the FluidMAX role of the unit which is NOT the center of the star topology to be a SLAVE. The FluidMAX engine is disabled. SLAVE OFF Table 7.2: FluidMAX Management options. 7.8 Advanced Wireless Settings The advanced wireless settings menu (Fig. 7.7) can be used to congure advanced wireless parameters:
FluidMAX Management. Although the FluidMAX engine automatically se-
lects the most appropriate MAC protocol to be used according to the de-
tected network topology, convenient selectors are included in the Web GUI to force the FluidMAX operations and control the FluidMAX role of the unit. Please refer to Table 7.2 for the available options and their specication. Transmission Rate Selection. Each FM unit implements a proprietary data-rate selection algorithm which is able to adapt to the specic radio channel conditions. Through this setting, it is possible to force the rate se-
lection algorithm to limit the modulation speed at a specic rate. This option might be useful with unstable channel conditions. Maximum TX Power. This setting controls the output power of the radio. By decreasing the output power of a radio, you can decrease the overall E.I.R.P. By default, the radio transmission power is controlled automatically by the innovative Fluidmesh Transmission Power Control (TPC) algorithm. The Fluidmesh TPC algorithm tries to obtain an optimal link signal strength
(about -55 dBm) on both sides of the link while not exceeding the maximum TX power which can be set by the user through the selector. Note that the maximum transmission power may vary depending on the operating fre-
quency channel of the radio. 42 Figure 7.7: Advanced wireless parameters conguration. Data Packet Encryption (Software Plug-in Required). Advanced En-
cryption Standard (AES) 128 bit encryption can be enabled at the link-level for wireless data transmission. This feature is available in addition to the default Fluidmesh proprietary encoding algorithm for maximum industry-
grade network security. A software Plug-in is required to activate this op-
tion. Please contact your Fluidmesh Networks representative for details. 7.9 Antenna Alignment Tools and Physical Statis-
tics The antenna alignment and stats page provides a powerful tool which can be used to check the current link status during the normal unit oper-
ation and the physical installation of the antennas. Specically, the web page shows the list of links detected by the local unit and the relative signal strengths (in dBm) on each radio as shown in Fig. 7.8(a). To perform an accurate antenna alignment for a specic link, click on the Align button to open the antenna alignment tool as depicted in Fig. 7.8(b). 43
(a) Link selection
(b) Alignment Figure 7.8: Antenna Alignment tool. 44 Figure 7.9: Frequency Scan Tool results. The user is warned that the proprietary Fluidmesh TPC algorithm (see Sec-
tion 7.8) will be disabled during the alignment process so as to avoid un-
wanted interactions with the tools. The antenna alignment tool consists of a real-time graph and a bar which report the average signal strength and the current signal strength detected at the local unit receiver, respectively. During the physical antenna alignment process, the graph and the bar can be monitored to obtain optimal link quality. 7.10 Frequency Scan Tool The Scan Tool page provides a powerful tool for analyzing the status of the radio interference in the available channels. The channel scan can be started on each radio separately by means of the buttons at the top of the page (see Fig. 7.9). As soon as the scanning is complete, a bar chart will appear indicating the current interference level and the overall quality of each channel. 45 As shown in Fig. 7.9, each bar in the chart consists of two sections. The black section represents the amount of interference detected in the chan-
nel, whereas the colored one gives a qualitative idea of the status of the channel according to the following table:
Color GREEN YELLOW RED Channel Quality GOOD FAIR BAD Additional information such as number of Fluidmesh units and access points detected is available by bringing the cursor of the mouse over the frequency channel bars. Please note that in a network with overlapping channels, the number of Fluidmesh units detected by the scan tool might be higher than the actual number of units deployed. 46 Figure 7.10: FMQuadro. 7.11 FMQuadro (Mesh End only) This feature is available only in FM units congured in Mesh End mode. The innovative FMQuadro engine provides an interactive graph representation of the Fluidmesh network where vertices and edges represent FM units and wireless links, respectively, as shown in Fig. 7.10. The links which are currently in use by every packet generated/relayed by a Fluidmesh device to reach a possible destination in the network (i.e., the routing table) are depicted as a continuous lines. Backup links are depicted as dashed lines, and they are not shown by de-
fault. Backup links can be viewed by selecting the appropriate eld in the top panel of the FMQuadro window. This panel also includes other elds which can be selected to display ad-
ditional always-on link information such as the link frequency, the link error rate, and the link quality. 47 In the graph, blue is the color of a mesh end whereas mesh points are de-
picted in red. The unit color becomes yellow if any anomalous condition is detected on the unit. Each element displayed in FMQuadro is interactive, and can be dragged and/or clicked to get additional real-time information based on the context. Figure 7.11: FMQuadro. Unit information. For example, by clicking on a specic unit, information about the remote unit selected is displayed in a callout as shown in Fig. 7.11. This informa-
tion includes the Layer 2 IP address, current FluidMAX status of the unit, the radio frequencies currently in use, and the details of the data trafc ows generated by the edge devices connected to the unit. The list of currently active Plug-ins is visible. Furthermore, any Plug-in Ac-
tivation Code can be conveniently added to the specic remote unit using the form available in the callout. Finally, current throughput and maximum capacity of the Ethernet port is reported in order to monitor the Ethernet ports utilization and detect whether the Ethernet port is over-utilized with respect to the installed FluidThrottle Plug-in. Similarly, the status of a wireless link connecting any two units can be mon-
48 itored by clicking on the related line, as reported in Fig. 7.12. Several real-
time parameters are displayed including the current signal strength, the packet error rate, and the link utilization of both link directions (i.e. the link from a unit to the other and vice-versa). Additionally, the current congestion level of the link is monitored. A detailed description of the available param-
eters is reported in Table 7.3. Visual alarms and warnings are triggered whenever anomalous conditions are detected, as described in Table 7.4. Warnings are of two types:
link and unit. When unit warnings are trig-
gered, the unit color becomes yellow. The warning details are available by clicking on the unit element. The link warnings notication can be disabled by removing the Warning ag in the FMQuadro top panel. Metric Current TX Rate Packet Error Rate Percentage of packet dropped due to excessive trans-
Description Current link transmission rate in Mb/s. Link Error Rate Signal Strength Link Utilization mission errors. Percentage of packet retransmissions due to trans-
mission errors. Current received signal level in dBm. Percentage of transmission in a pie chart format. link utilization for data the current Table 7.3: Link metrics description. Type Cause Warning Link Low Signal Strength Link High Error Rate High Link Congestion Link Ethernet Capacity Overow Unit Unit Hidden Terminal Detected Link Signal Strength < 60%. Packet Error Rate > 5%. Link Utilization > 80%. Plug-in capacity exceeded. Hidden terminal detected by the FluidMAX engine. Table 7.4: FMQuadro warning description. Through the link status callout, the user can also check the level of interfer-
ence of the selected link by clicking on the Check for Interference button. The link interference is analyzed on both sides of the link by the FMQuadro engine and the interface suggests, in case of detected problems, a set of preferred channel frequencies that the radio link is recommended to be set to. All the link metrics are continuously monitored by the FMQuadro engine 49 and statistics are logged and can be displayed by clicking on any link met-
ric button, as shown in Fig. 7.13. By default, the last 48 hours statistics are recorded with a metrics sampling interval of 5 minutes. The statistics recording time can be increased up to 24 days at the cost of increasing the metricss sample interval proportionally. Figure 7.12: FMQuadro. Link information. A table, placed at the bottom of the window, reports the network units ad-
dress summary and can be viewed by clicking on the proper button as re-
ported in Fig. 7.14. It is possible to assign a name to each of the Fluidmesh units. This may be especially convenient with a large mesh network. Furthermore, through the Network Settings table, placed at the bottom of the window, you can check whether the DFS settings are consistent the network, e.g., the DFS is enabled in the all the units. The Network Settings table allows for harmonizing the DFS settings in the whole network with a single mouse click. FMQuadro is an accurate representation of the network, so it can be use-
50 Figure 7.13: FMQuadro. Last 48 hours Link information. Figure 7.14: FMQuadro. Addresses Summary table. 51 ful to add a map of the area in which the Fluidmesh system is deployed.2 Map images can be uploaded to the Mesh End unit using the proper button placed in the FMQuadro top toolbar. Common image formats are supported including png, jpg and bmp. Furthermore, whenever an Internet connection is available to the user PC used to congure the Fluidmesh network, Google Maps map can be used to set the background of FMQuadro.3 The top tool-
bar provides several intuitive buttons to drag & drop the background map and control its transparency and scale. Once the map is set up, the FM units can be dragged to their actual installation places. Finally, the modied layout can be saved and used again in the future. As the FMQuadro engine collects statistics from the entire network through the Mesh End unit, it is no longer necessary to directly connect to remote units. The overall network status and individual device status can be moni-
tored real-time through the FMQuadro interface on Mesh End unit. 2Aerial images can be downloaded using Google Earth (http://earth.google.com/). 3Please note the you need an Internet connection to use the Google Maps background feature. 52 Figure 7.15: VLAN conguration steps. 7.11.1 VLAN Tagging Conguration (Software Plug-in Required) Each VLAN can be congured via FMQuadro with a simple two steps pro-
cedure as described below. Please note that VLANs require some network conguration expertise and should be used by advanced users only. Please refer to Section 5.2.1 for further details. 1. VLAN ID creation: a new VID can be created using the VLAN man-
ager control placed at the bottom-right hand of the FMQuadro window as shown in Fig. 7.15. You must specify the VID number and, op-
tionally, a description of the VLAN. Once the VID is created you can specify the Ethernet ports and/or the MAC addresses membership. 2. Ports and/or MAC membership: FM unit ethernet ports can be added to the created VLAN by using the specic callout of the unit as shown in Fig. 7.15. On the other hand, MAC addresses member-
ship can be specied in the VLAN manager control. 53 The Fluidmesh VLAN implementation is compatible with the specication of the IEEE 802.1q standard and, thus, the Fluidmesh network can inter-
operate with other VLAN-aware network devices. VLAN trunking between the Fluidmesh network and Ethernet switches is also supported and can be enabled by selecting the proper control in the units callout window. En-
abling VLAN trunking on a specic port instructs the FM unit to forward VLAN membership information to the device connected to the port, thus extending VLANs across multiple network devices. To simplify the conguration of the units when trunking is enabled, a special VID #1 is available. Simply conguring the network switch with a VLAN #1 will allow any PC belonging to the VLAN #1 to access the web interface of the FM units without the need for additional settings of the FM units. 7.12 Firmware Upgrade Through the rmware upgrade page (Fig. 7.16), it is possible to upgrade the Firmware of the devices to the latest version available. To do so, down-
load the latest Firmware upgrade le to your PC from the Fluidmesh Net-
works Web site at www.uidmesh.com.4 Select the correct le on your hard disk, and upload it. This operation might take several minutes. The unit will automatically reboot at the end of the upgrade process. Upgrading a working system is always a delicate and somewhat risky oper-
ation. Fluidmesh discourages anybody from upgrading a functional system except if there is an issue to x. Recommended upgrading procedure for running systems:
1. Download the latest rmware release available for your hardware/rmware family;
2. Power off the whole network;
3. Power on one device at a time;
4. Connect directly to the Fluidmesh unit to be upgraded directly through an Ethernet cable;
5. Write down the unit conguration (at least network settings and wire-
less settings);
4An approved Fluidmesh extranet account is required. Please register for a an on-line account and contact Fluidmesh for approval. 54 6. Upgrade the device with the chosen rmware;
7. Once the upgrade is completed, wait for the system to reboot;
WARNING: DO NOT RESTART OR POWER OFF THE UNIT WHILE UP-
GRADING THE FIRMWARE. RESTARTING OR POWERING OFF THE UNIT BEFORE THE UPGRADE IS COMPLETED MIGHT DAMAGE THE UNIT. When the upgrade is completed, check the rmware upgrade page in order to make sure that the new rmware version has been correctly up-
dated. If the rmware version has not been changed, the upgrade process has failed. Therefore, please repeat the upgrading procedure from the be-
ginning. Figure 7.16: Firmware upgrade Web page. 55 Figure 7.17: Plug-ins management Web page. 7.13 Plug-in Management The manage plug-ins page (Fig. 7.17) shows the installed Plug-ins and allows the user to add Plug-in Activation Codes. Additionally, a Plug-in can be deactivated to, for example, transfer it from one unit to another. Once the Plug-in has been deactivated, you will be provided with a Deactivation Code displayed at the bottom of the page. In order to get a fresh Activation Code to use it in another device, you must complete the unit deactivation pro-
cedure at the Fluidmesh Networks website (www.uidmesh.com). Please refer to Section 6 for details on the software Plug-in activation/deactivation procedures. A 8 hour plug-in trial is available by clicking on the Demo Mode button at the bottom of the page. The plug-in demo mode includes the 4.9 GHz5, the AES and the Unlimited plug-in trials all at once. The unit will reboot on the 8 hours plug-in trial expiration. 5Not available in Brazil. 56 7.14 Advanced Tools Through the advanced tools page, it is possible to run tests to verify net-
work connectivity and the achievable throughput on a network path. As shown in Fig. 7.18, network connectivity can be tested by issuing a Ping Test towards a specic destination. Additionally, the Bandwidth Test tool generates a stream of packets at a specied rate to test the available net-
work path throughput.6 In order to run a Ping or a Bandwidth Test, write the destination IP in the proper window and click run. The Bandwidth Test allows you to select the throughput from a value of 4Mb/s to 20 Mb/s. Both tests can be run on top of a loaded network to test operational performances, or on top of an unloaded network to test installed capacity. Figure 7.18: Advanced Tools Web page. 6Please note that the achievable rate computation is cpu-intensive and only indicative. Results may be not accurate. Usually the bandwidth tests tend to underestimate the real throughput of the link. 57 7.15 Multicast By default, FM units operating in Mesh Point mode forward all the multicast trafc generated by the cameras to their closest Mesh End unit. However, in some network congurations, it may be convenient to forward the multi-
cast trafc from a Mesh Point to others, e.g., to remotely record the video ow. By default, the unit operating in Mesh End mode does NOT forward any multicast trafc7 to the wireless networks. Figure 7.19: Add/Remove multicast routes towards Mesh Points. To redirect a trafc ow to a Mesh Point, you must specify all the multicast ows redirection information within the Mesh End multicast page as shown in Fig 7.19. 7With the exception of UPnP and IGMP trafc. 58 7.16 PoE Passthrough (FM1100 and FM1200 only) The second Ethernet port present on the FM1100 and FM1200 can be used to power up other passive 12-18 V PoE devices such as cameras and FM units. This feature can be enabled through the PoE passthrough page as depicted in Fig. 7.20. Figure 7.20: Enable the PoE passthrough feature. 7.17 Change Password Use this page to change the password to access the unit Web GUI. 7.18 Status This page reports asummar y of the status of the unit. Additionally, in case of system malfunctions, the units diagnostic le dump can be downloaded 59 through this page and emailed to the Fluidmesh technical support to facili-
tate the problem diagnosis. 7.19 Reboot and Reset to Factory Default Use the Reboot page to restart the unit. Use the Reset to Factory Default page to restore the unit default factory settings. 7.20 On-line Help The electronic version of this manual is available by accessing the Help web page. Additionally, specic manual sections can be consulted by clicking on the question mark present at the upper right corner of every page of the Web GUI. 60 8 Troubleshooting The troubleshooting section will allow you to solve the most common prob-
lems encountered when conguring and installing Fludimesh products. 8.1 I am unable to get the log-in screen If you are unable to get the log-in form on your computer screen, you should check the following:
Is your computer set to a valid IP address? You should manually set the correct network settings as follows:
1. In Windows Explorer, right-click My Network Places and select Prop-
erties. 2. Right-click Local Area Network and select Properties. 3. Right-click Internet Protocol (TCP/IP) and select Properties. 4. Set the IP address to 192.168.0.30 (or any other IP address belonging to the subnet 192.168.0.0/255.255.255.0), Netmask to 255.255.255.0. 5. Click OK, then OK again. Have you disabled the Access the Internet using a proxy server function?
To disable the Access the Internet using a proxy server function, go to Control Panel > Internet Options > Connections > LAN Settings and uncheck the enable box. 8.2 I am unable to log-in into the Web-based inter-
face If you are unable to log-in into the Web-based interface, check your user name and password settings. The user name cannot be changed by the user and corresponds to:
61 admin The password can be changed, so make sure you are using the right pass-
word. The default password is:
If you forgot the password, check Section 8.3 to x the problem. admin 8.3 I forgot the administrator password If you forgot the password and need to access the Web-based interface, you must physically access the unit, open the enclosure in a weather-safe situation and reset to the factory default settings. Please refer to the in-
structions of Section 3.1.4 for FM1100, Section 3.3.4 for FM1200 and Section 3.2.4 for FM3100 units. 8.4 In Bridge Mode I get no Link or the Link LED is always red or I am getting a weak Wireless link
(below 60% signal strength) To improve your link strength, please check the following:
Antenna Alignment:
other. the two antennas must be aligned toward each Line of Sight:
antennas. you must have clear line of sight between the two Antenna Polarization:
both antennas must have the same polariza-
tion. Check antenna polarity. Power: check if the FM unit is properly powered-on with the provided PoE injector. Channel: both FM unit units must be operating on the same channel. 62 APPENDIX A FCC Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Change or modification not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help. CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. RF exposure warning:
The equipment complies with FCC RF exposure limits set forth for an uncontrolled environment. The equipment must not be co-located or operating in conjunction with any other antenna or transmitter. 40 This device is operation in 5.15 5.25GHz frequency range, then restricted in indoor use only, Outdoor operations in the 5150~5250MHz is prohibit. 63 APPENDIX C Contact Information Worldwide Headquarters Fluidmesh Networks, LLC 1359 Barclay Boulevard Buffalo Grove, IL 60089 U.S.A. Tel. +1 (617) 209 -6080 Fax. +1 (866) 458-1522 info@fluidmesh.com EMEA Headquarters (Italy) Tel. +39 02 0061 6189 UK Branch Tel. +44 2078 553 132 www.uidmesh.com 65 Worldwide Headquarters Fluidmesh Networks, LLC 1359 Barclay Boulevard Buffalo Grove, IL 60089 U.S.A. Tel. +1 (617) 209 -6080 Fax. +1 (866) 458-1522 info@fluidmesh.com EMEA Headquarters (Italy) Tel. +39 02 0061 6189 UK Branch Tel. +44 2078 553 132 www.uidmesh.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2013-04-29 | 5190 ~ 5230 | NII - Unlicensed National Information Infrastructure TX | Original Equipment |
2 | 5755 ~ 5795 | DTS - Digital Transmission System |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2013-04-29
|
||||
1 2 | Applicant's complete, legal business name |
Fluidmesh Networks LLC
|
||||
1 2 | FCC Registration Number (FRN) |
0022185987
|
||||
1 2 | Physical Address |
81 Prospect St.
|
||||
1 2 |
Brooklyn, NY
|
|||||
1 2 |
United States
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
T******@babt.com
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
R5S
|
||||
1 2 | Equipment Product Code |
FV
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
G******** S********
|
||||
1 2 | Title |
Hardware Engineering Manager
|
||||
1 2 | Telephone Number |
+1617********
|
||||
1 2 | Fax Number |
+1617********
|
||||
1 2 |
g******@fluidmesh.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | NII - Unlicensed National Information Infrastructure TX | ||||
1 2 | DTS - Digital Transmission System | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | WiFi AP | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power listed is conducted. Operations in the band 5.15-5.25GHz is restricted to indoor usage only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except as described in this composite filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 2 | Output power is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 40 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the requirements for satisfying RF Exposure compliance. | |||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
DEKRA TESTING AND CERTIFICATION CO., LTD. LinKou
|
||||
1 2 | Name |
S****** H****
|
||||
1 2 | Telephone Number |
+886-******** Extension:
|
||||
1 2 | Fax Number |
+886-********
|
||||
1 2 |
s******@dekra.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15E | CC | 5180 | 5240 | 0.0121 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15E | CC | 5190 | 5230 | 0.0118 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 5745 | 5825 | 0.955 | |||||||||||||||||||||||||||||||||||
2 | 2 | 15C | 5755 | 5795 | 0.91 |