1 |
|
Annex prof. use declaration | Users Manual | 96.87 KiB | January 13 2020 | |||
1 |
|
user manual | Users Manual | 4.28 MiB | January 13 2020 | |||
1 |
|
int photos | Internal Photos | 911.07 KiB | January 13 2020 | |||
1 |
|
ext photos | External Photos | 1.09 MiB | January 13 2020 | |||
1 |
|
label and location | ID Label/Location Info | 275.47 KiB | January 13 2020 | |||
1 |
|
LTC request | Cover Letter(s) | 31.71 KiB | January 13 2020 | |||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 110.67 KiB | January 13 2020 | |||
1 |
|
Test report | Test Report | 1.11 MiB | January 13 2020 | |||
1 | block diagram | Block Diagram | January 13 2020 | confidential | ||||
1 | operational description | Operational Description | January 13 2020 | confidential | ||||
1 | parts list | Parts List/Tune Up Info | January 13 2020 | confidential | ||||
1 | schematics | Schematics | January 13 2020 | confidential | ||||
1 |
|
test setup photos | Test Setup Photos | 993.02 KiB | January 13 2020 |
1 | Annex prof. use declaration | Users Manual | 96.87 KiB | January 13 2020 |
Mistelgau, Seite 1 von 1 Date: 13 January 2020 PHOENIX TESTLAB GmbH Product Certification Knigswinkel 10 D 32825 Blomberg FCC ID: 2AP5OLFM-4X Subject: Professional Installation To Whom It May Concern:
We hereby declare, that the device with the above referenced FCC ID is subject to Professional Installation and complies with the applicable requirements as defined in KDB353028 D01 Antennas Part 15 Transmitters. The device will be certified with a ferrite-antenna HRF.A.LFX.SM.SS.15 and marketed exclusively for use in industrial environments as documented in the FCC filing. We have full control over the marketing as it can only be purchased directly from us, so that we know each individual customer. Especially the proper set-up with countless of different selection features requires skilled technical competence and understanding of the system. Either we offer dedicated installation training sessions, or the device will be alternatively installed by our own staff. If you have any questions, please feel free to contact me. Yours sincerely, Lothar Dngfelder, Development, T&T Vorstand: Jrg Herrmannsdrfer, Uwe Herrmannsdrfer, Harald Khler Vorsitzender des Aufsichtsrates: Peter Heun, Rechtsanwalt AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen: HypoVereinsbank AG Bayreuth, Konto 329 829 383, BLZ 773 200 72 IBAN: DE63 7732 0072 0329 8293 83, SWIFT: HypoVereinsbank AG HYVEDEMM412 Commerzbank AG Bayreuth, Konto 1 311 166, BLZ 773 400 76 IBAN: DE16 7734 0076 0131 1166 00, BIC: COBADEFF773 VR-Bank Bayreuth, Konto 9 603 743, BLZ 773 900 00 HERMOS AG Gartenstrae 19 D-95490 Mistelgau Telefon: +49 (9279) 991-0 Telefax: +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com
1 | user manual | Users Manual | 4.28 MiB | January 13 2020 |
WE GENERATE SOLUTIONS RFID Englisch Customer manual LFM 4x Reader Rev1.4 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 1 WE GENERATE SOLUTIONS 0. Table of contents Customer manual LFM 4x Reader RFID 0. Table of contents .................................................................................................................................. 2 1 . I n t r o d u c t i o n ............................................................................................................................... 6 1.1 Using the device 7 2. Version history ...................................................................................................................................... 8 3. Used abbreviations and designations ................................................................................................... 8 4. General instructions .............................................................................................................................. 9 4.1 Objective of the product manual 4.2 Warranty and liability 9 9 5. Safety instructions and warnings ........................................................................................................ 10 5.1 Scope and symbols 5.2 Safety symbols - according to DIN 4844-2 5.2.1 Mandatory signs 5.2.2 Warning signs 5.2.3 Prohibition signs 5.2.4 Other signs 5.3 Obligations 5.3.1 Operators obligations 5.3.2 Responsibilities of operating personnel 5.3.3 ESD Instructions 5.4 Residual risks 5.5 Supplemental instructions 5.5.1 Regulations and certifications 10 10 11 11 11 12 12 12 13 13 14 15 15 6. Functional description ......................................................................................................................... 16 6.1 General information 6.2 Basic functions - operating modes 6.2.1 Normal operation 6.2.2 Polling mode 6.2.4 Test module 6.3.1 Top view 6.3.2 Front view 6.3.3 Back view 6.4 Technical Specification 6.4.1 Power supply and current input 6.4.2 Device labels 6.4.3 Device Label FCC ID 2AP5OLFM-4x 16 16 16 16 16 17 18 19 20 20 21 21 Feh HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 2 WE GENERATE SOLUTIONS ler! Textmarke nicht definiert. 6.4.4 Test mode sticker Customer manual LFM 4x Reader RFID 22 7. Installation ........................................................................................................................................... 23 7.1 Safety instructions 7.2 Qualified installation personnel 7.3 Unpacking 7.4 Mounting the device 7.5 Installing the antenna 7.5.1 Positioning the antenna 7.5.2 Rod Antenna M dimensions 7.5.3 Connecting the antenna 7.6 Power Supply 7.7 DIP-switch 7.8 RS232 connection 23 24 24 25 26 26 27 27 27 28 29 8.Commissioning .................................................................................................................................... 30 8.1 Operating conditions 8.2 The serial interface parameters 8.3 Parameter of the ethernet interface 8.3.1 Change networksettings with DeviceDiscoverer 8.3.2 Firmware update with DeviceDiscoverer 8.3.3 Test Device with DeviceDiscoverer 30 30 31 31 33 34 9. Operating ............................................................................................................................................ 37 9.1 Operating personnel 9.2 Protocol change 9.2.1 General 9.2.2 Automatic protocol detection 9.3 Addressing the antenna port 9.4 Customer Factoryparametersets 37 37 37 37 38 39 10. ASCI-I1 Communication protocol ..................................................................................................... 40 10.1 Structure of the communication protocol 10.2 Packet content Packet header Message data Packet end 10.3 Data elements 10.4 Protocol Commands 10.4.1 X - Read data 10.4.2 R Automatic read 10.4.3 W - Write data HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com 40 40 40 41 41 42 45 47 48 49 LFM 4x Reader Rev1.4 www.hermos.com 3 50 51 52 53 54 54 55 56 57 58 59 60 61 62 63 64 67 69 71 71 73 75 Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS 10.4.4 G Query parameter 10.4.5 F Query parameter 10.4.6 P Set parameter 10.4.7 N Reset 10.4.8 e Error message 10.4.9 E Error message 10.4.10 H Heartbeat 10.4.11 V Query software version 10.4.12 L - Lock data area 10.4.13 I Adjust RF module 10.4.14 J RF module Queries the vote 10.4.15 A Sensor event object removed 10.4.16 B Sensor event object detected 10.4.17 O Set output 10.4.18 Q Querying the status of the inputs and outputs 10.5 Parameter 10.6 Message examples 10.7 Error Codes 10.8 Wiring of the outputs 10.8.1 ASC-W1 Mode: Reader in operation mode and sensor triggered reading 10.8.2 ASC-W1-Mode: Reader in operation mode and external triggered reading 10.9 ASCII table 11.SECS / HSMS Communications protocol .......................................................................................... 78 11.1 Structure of a message 11.2 Directory Data Elements 11.3 Protocol commands 11.3.1 Stream 1 (system state) 11.3.2 Stream 2 (system control) 11.3.3 Stream 3 (Material-state) 11.3.4 Stream 5 (Exception handling) 11.3.5 Stream 9 (system error) 11.3.6 Stream 18 (control and data transfer) 11.4 Parameter 11.5 Examples of a SECS / HSMS message 11.6 Error codes 78 81 87 88 89 91 93 93 95 101 109 110 12. Service and Troubleshooting ................................................................................................... 111 111 12.1 General information 12.2 Troubleshooting personnel 111 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 4 WE GENERATE SOLUTIONS 12.3 Safety instructions 12.4 Error indications on the device 12.5 No communication with the reading device 12.6 Software releases 12.7 Customer service Customer manual LFM 4x Reader RFID 112 113 113 114 115 13. Disassembly and storage ........................................................................................................ 116 116 13.1 Disassembly 13.2 Storage 116 14. Transport and disposal ........................................................................................................ 116 116 14.1 Transport 14.2 Disposal 116 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 5 WE GENERATE SOLUTIONS 1 . I n t r o d u c t i o n Customer manual LFM 4x Reader RFID These operating instructions correspond with the "Radio and Telecommunications Terminal.Equipment Act and Directive 2014/53/EU (RED) "
These operating instructions are intended for the operator who must pass these on to the personnel responsible for installation, connection, use, and repairs of the machine. The operator must ensure that the information contained in these operating instructions and in the accompanying documents has been read and understood. The operating instructions must be kept at a known place that is easy to reach, and they must be consulted if there is the slightest doubt. The manufacturer assumes no responsibility for damage to persons, animals, or objects or to the unit itself arising from the improper use or the disregard or insufficient consideration to the safety criteria contained in these operating instructions or based on modifications of the unit or the use of unsuitable replacement parts. The copyright for the operating instructions lies solely with HERMOS AG Track & Trace - RFID Division Gartenstr. 19 95490 Mistelgau or its legal successor. Reproduction or circulation of this document to third parties only by express written permission of copyright holder. This also applies if only excerpts of the document are copied or circulated. These same conditions apply to the disclosure of the document in digital format. As of: July - 2018 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 6 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 1.1 Using the device The device is exclusively used to read and write passive LF transponders. Any other use of the machine or any use beyond its intended purpose is considered non-intended and thus improper. In this case, the device safety and the device protection provided may be compromised. HERMOS AG is not liable for damages resulting from such use. The device was developed for the use in an industrial environment as a built-in device in other systems. It was not developed as a stand-alone or mobile device in a non-industrial environment, such as dome- stic, vehicle or open air use. Intended use also includes the following:
Following all the operating instructions Following all the safety instructions Improper use, which can endanger the unit, the user and third parties, include:
The use of the device contrary to its intended use Changes to the device as well as attachments and conversions Operating the unit when there are obvious problems WARNING Danger of injury due to unauthorised modifications There are risks from unauthorised modifications on the device. Only original spare parts from the manufacturer must be used. No modification, attachment or conversion may be performed on the device without the permission of HERMOS AG. WARNING Danger of injury and interruption of operation due to improper use There are risks through the improper use of the device. The device must only be used according to its intended use. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 7 WE GENERATE SOLUTIONS 2. Version history Version Date Author Customer manual LFM 4x Reader RFID Amendments 12.05.2017 HERMOS AG, MZ Initial version of customer documentation 10.07.2017 HERMOS AG, RK Document revised and added parameters 19.01.2018 HERMOS AG, RK ASC-W1 mode documented 09.07.2018 HERMOS AG, RK Factoryparametersets 4 and 5 documented 26.02.2019 HERMOS AG, RK Chapter 9.3 and Reader-ID revised Chapter 9.4 Factoryparametersets revised Chapter 10.5 und 11.4 Changes of parameters Chapter 12.6 added softwarerevision V1.5 Chapter 8.3 revised 1.0 1.1 1.2 1.3 1.4 3. Used abbreviations and designations RFID LF SEMI SECS HSMS PoE DHCP Radio Frequency Identification Low Frequency 134,2 kHz Semiconductor Equipment and Materials SEMI Equipment Communications Standard High-Speed SECS Message Service Power over Ethernet Dynamic Host Configuration Protocol HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 8 WE GENERATE SOLUTIONS 4. General instructions Customer manual LFM 4x Reader RFID All previous versions of this document lose their validity with the issue of this version. We compiled the information in this document according to the best of our ability. HERMOS AG does not guarantee the accuracy and completeness of the information provided in this document and is also not liable for consequential damages based on faulty or incomplete information. 4.1 Objective of the product manual The product manual serves as support and contains all the necessary information that must be followed for general safety, transport, installation and operation. The product manual with all safety instructions (as well as all additional documents) must be:
Followed, read and understood by all persons working with the unit (especially knowledge of the safety instructions) Easily available at all times to all persons Consulted if even the slightest doubt arises (safety) Objectives:
Prevent accidents Increase the service life and reliability of the unit Reduce the costs of production downtime 4.2 Warranty and liability The General Terms and Conditions of Sale and Delivery of HERMOS AG shall apply. The warranty period is 24 months beginning with the delivery of the device, which is verified by the invoice or other documents. The warranty includes repairs of all damages to the unit that occur during the warranty period, and were clearly caused by material or manufacturing defects. Warranty and liability claims in the event of personal injury or property damage are excluded if they arise from one or more of the following causes:
Improper use of the unit Disregarding the information in the operating instructions Unauthorised structural modifications of the unit Insufficient maintenance and repairs Disaster events due to impact with foreign objects or force majeure HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 9 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 5. Safety instructions and warnings 5.1 Scope and symbols Follow the general safety instructions as well as special safety instructions included in the chapters. The unit was built according to state-of-the-art technology and recognised safety regulations. In order to prevent danger to life and limb of the user, third parties, or the unit, only use the unit for its intended purpose and in perfect condition with regard to safety. Bodily injuries and/or property damages resulting from non-compliance with the instructions pro- vided in the operating instructions are the responsibility of the company operating the unit or the assigned personnel. Faults that may compromise safety must be eliminated immediately. DANGER Risk of death, injury and property damage. There is a risk of danger due to disregard of the product manual and the safety information contained therein. Read the product manual carefully before putting the unit into operation for the first time. Fulfil all required safety conditions. 5.2 Safety symbols - according to DIN 4844-2 The following special safety symbols in accordance with DIN 4844-2 are used at the corresponding passages in the text of this product manual and require special attention depending on the combi- nation of the signal word and symbol. DANGER Risk of injury due to disregarding the safety symbols. Risks exist when disregarding warnings in the operating instructions. Follow all warnings. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 10 WE GENERATE SOLUTIONS 5.2.1 Mandatory signs Observe additional information Wear ear protection Important note 5.2.2 Warning signs Warning of a hazardous area Warning of electromagnetic radiation Warning of explosive substances 5.2.3 Prohibition signs Unauthorised access is prohibited Switching prohibited Customer manual LFM 4x Reader RFID Use safety goggles Wear safety shoes Warning of hazardous electrical voltage Warning of flammable substances Warning of electrostatically sensitive components Fire, open flame and smoking prohibited Prohibited HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 11 WE GENERATE SOLUTIONS 5.2.4 Other signs Verpackungsmaterial vor-
schriftsgem entsorgen Customer manual LFM 4x Reader RFID Recycling 5.3 Obligations 5.3.1 Operators obligations A safe condition and use of the unit is a requirement for a safe operation of the unit. For that rea-
son, the operator has the obligation to ensure that the following points are adhered to:
The unit may only be operated by trained and authorised personnel. Prohibit unsafe or dangerous working methods! If necessary, check the conduct and actions of its personnel!
Have personnel who must be trained, instructed or within the scope of general training work only on the unit under the supervision of an experienced person!
Have the personnel confirm by their signature that the operating instructions have been understood!
Precisely establish responsibilities according to the various task areas (operation, installation)!
Operating personnel must be required to immediately report any occurring and identifiable safety deficiencies to their superior!
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 12 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 5.3.2 Responsibilities of operating personnel The operating personnel are obligated to contribute to the prevention of work accidents and their consequences by their personal conduct. Risk of injury due to insufficient personnel qualifications There are dangers to personnel and the proper operation due to inadequately qua- lified personnel. Only trained personnel may operate the unit. New operating personnel must be instructed by the existing operating personnel. The operator must precisely regulate the personnels areas of responsibility, com- petence, and monitoring precisely. The personnel for the areas of responsibility mentioned above must have the corresponding qualification for this work (training, instruction). If necessary, this can be done by the manufacturer on behalf of the operator. In case of disregard, all warranty claims are void. WARNING 5.3.3 ESD Instructions CAUTION Static electricity can damage electronic components in the unit. All persons who install or maintain the unit must be trained in ESD protection. ESD protective measures must be applied when opening the unit. Disconnect the power supply prior to removing or adding components!
Observe the basic principles of ESD protection Take the appropriate ESD precautionary measures HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 13 WE GENERATE SOLUTIONS 5.4 Residual risks Customer manual LFM 4x Reader RFID Despite all precautionary measures taken, there may still be residual risks that are not apparent. Adhering to the safety instructions, the intended use, and the product manual as a whole can re- duce residual risks. DANGER ATTENTION DANGER WARNING Danger caused by electrical current Electrical residual energy remains in lines, equipment and devices after shutting down the device. Only qualified electricians may perform work on the electrical supply system. Disconnect the unit from the power supply system if active parts of the unit can be accessed using tools. Access is only permitted by authorised personnel. Regularly check the electrical equipment of the unit. Regularly check all moving cables for damage within the scope of maintenance and repair work. Dangers of fire and explosion There is a risk of fire and explosions in the vicinity of the device. Smoking, exposed flames and fire are strictly prohibited in the vicinity of the unit. Do not store any flammable liquids within the hazardous area of the device. A fire extinguisher must be kept in the vicinity of the device. Warning of electromagnetic radiation Electromagnetic radiation develops when transmitting and receiving data. Arrange the antenna in such a position that it is not in the vicinity or make contact with the human body while transmitting. The device satisfies the standard EN50364:2010 (Human Exposure). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 14 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 5.5 Supplemental instructions Read and understand all safety and operating instructions prior to installing and operating the device. This documentation was written for specifically trained personnel. The installation, operation and error handling may only be carried out by specifically trained personnel. Keep these instructions. Keep this documentation in a location that is accessible to all personnel involved with the installation, use, and error handling of the device. Follow all warnings. Follow all warnings on and in the device and in the documentation. Install the unit only in accordance with the manufacturers instructions. Use only the accessories and cables from the manufacturer. Troubleshooting that is not described in the chapter a service and troubleshooting may only be performed by the manufacturer. When connecting cable connections, only pull on the plug and not on the cable. Only use spare parts specified by the manufacturer. The provisions of the accident-prevention regulations of the government safety organisations always apply to all work on the unit. Applicable, legally binding accident prevention regulations. Applicable binding regulations at the place of use Technical standards for safety and professional work Existing environmental protection regulations Other applicable regulations 5.5.1 Regulations and certifications The electrical design and documentation satisfy the DIN / VDE, EN / IEC regulations. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 15 WE GENERATE SOLUTIONS 6. Functional description 6.1 General information Customer manual LFM 4x Reader RFID LF reading devices are radio frequency identification systems that use radio transmission to read or write data of LF transponders (134,2 kHz), which operate as tamper-proof electronic tags. The LF reading devices communicate with common transponders (134,2kHz) according to ISO 18000-2 and ISO 11785 that are available on the market. The data is transmitted via the existing interface with the preset transmission parameters. If seve-
ral interfaces are available and connected to the host, the transmission is always carried out on the most recently used interface. The data is embedded in a defined communication protocol and exchanged between the reader and host. 6.2 Basic functions - operating modes During normal operation, the LF reading device supports various basic functions:
Heartbeat function, software version query Scanning of transponders in the antenna area (UID) Reading data Writing data Locking data Setting and reading out parameters Setting and querying inputs and outputs The LF devices can be set in 3 other operating modes by setting the parameters: Polling operation
(optional), sensor-triggered automatic reading and test mode. 6.2.1 Normal operation During normal operation, the LF reading device is immediately ready for operation after a reset. It does not perform any automatic actions in this mode (standby). During normal operation, actions are triggered by protocol commands from the host. A scanning procedure or reading in the data area is initiated by a command of the host system using the communication protocol. In addition to the actions triggered by the host, a corresponding message can be automatically sent to the host and an automatic reading operation can be started by activating or releasing a sensor. When the reading operation is successful, the read data is immediately transmitted to the host. If several antenna ports are occupied simultaneously, the reading operations are processed sequen-
tially. Writing actions (data saved to a transponder) are generally only possible via commands from the host. 6.2.2 Polling mode LF reading devices can be set into a continuous reading state, which is referred to as polling mode. The device then performs reading operations at regular intervals and outputs the corresponding data of the read LF transponder. The reading device also continues carrying out protocol messages in polling mode. This may, however, result in delays in the poll rhythm. The polling functionality is optional customer-specific available!
6.2.4 Test module HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 16 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID The HERMOS LF reading devices support a test mode that facilitates setting up the antenna and checking the reading ranges during commissioning. HF reading devices feature several DIP swit-
ches on the housing. These switches can be used to activate test mode. The functions in test mode are described on a sticker located on the reading device housing. The evaluation of the DIP switch depends on parameters If the device is in test mode, the red status LED flashes at about 1 Hz. The yellow status LED then indicates the status of the test mode. If the read or write process was unsuccessful, the yellow LED flashes at the read or write frequency. If the read or write process is successful, the yellow LED remains permanently lit. With the existing I / O module, HERMOS LF readers with ASC-W1 protocol also show the success-
ful or incorrect reading of the transponder at the respective first output port. See also behavior of the output ports in test mode. see also chapter DIP-switch 6.3 Illustration 6.3.1 Top view 1. Black and white anodised aluminium housing 2. Reading device type imprint 3. Data Matrix Code www.hermos.com HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 17 Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS 6.3.2 Front view Power supply connection Status- and power LEDs DIP-switch Ethernet interface RS232 interface 1. 2. 3. 4. 5. Component Description Power supply connection Power-LED Status-LEDs DIP-switch Ethernet interface Three-pin socket for the connection of the 24V DC power supply. The power LED indicates that the operating voltage is present and the rea- ding device is ready for operation. The two status LEDs are used for the reading and writing feedback in test and polling mode. If the device is in test mode, the red status LED flashes at about 1 Hz. The yellow status LED then indicates the status of the test mode. If the read or write process was unsuccessful, the yellow LED flas- hes at the read or write frequency. If the read or write process is successful, the yellow LED remains permanently lit. In normal operation, if an error occurs, the display of this occurs via the red LED:
Red LED constantly on: read error (no tag) red LED flashing rapidly: antenna error (tuning, cable break). This display will reset automatically with the next valid reading. After a restart, a short self-test of the LEDs, then display of the protocol: SECS: The red LED goes on briefly ASCII: The yellow LED goes on briefly DIP-switch 4 starts an automatic antenna tuning. DIP-switch 3 activates a test mode. DIP-switch 1 and 2 serve the antenna selection. The reading device features an Ethernet interface depending on the de- vice model. The communication with the device can be carried out via the 10/100 BaseT interface. RS232 interface Depending on the device model, the reading device features a RS232 in- terface. The communication with the device can be carried out via the serial interface (9-pin Sub D) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 18 WE GENERATE SOLUTIONS 6.3.3 Back view Customer manual LFM 4x Reader RFID HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 19 WE GENERATE SOLUTIONS 6.4 Technical Specification Technical data Voltage (protected against reverse polarity) Power consumption
(passive, reading, pulse-by-pulse) Customer manual LFM 4x Reader RFID 20 28 V DC, 75mA@24V, 200mA, max.400mA Fuse type Nano2 Operating temperature 375 mA
-0 to 50 C Storage temperature
-20 C to 70 C Permissible humidity at 50C 25 80 %
Transmission frequency 134,2 kHz Ethernet interface 10/100 BaseT, Protocol ASCII, SECS / HSMS Housing material Aluminium, black and white anodised Protection IP40 Reader dimensions 130 x 124 x 45 mm Weight approx. 500 g 6.4.1 Power supply and current input Description Min. Typ Max. Unit Voltage (reverse polarity protected) 20 Current consumption (Read/Write Pulse manner (50ms) Current (passive) 24 110 330 80 28 V (DC) mA mA HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 20 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 6.4.2 Device labels The device label is located on the reading unit housing. It contains a CE mark, article/serial number and the MAC address. 1. Designation 2. Article number (variants) 3. Serial number (example) 4. MAC address 5. Manufacturer 6.4.3 Device Label FCC ID 2AP5OLFM-4X LFM Reader 4x P/N: HRF.R.LFM.4x.Xx.xx.xxx S/N:
P/O: HKxxxxxx MAC: D8:80:39:xx:xx:xx HERMOS AG 1704HAG00123 FCC
- The Federal Communications Commission (FCC) warns the users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF exposure statement (mobile and fixed devices) This device complies with the RF exposure requirements for mobile and fixed devices. However, the device shall be used in such a manner that the potential for human contact during normal operation is minimized.
- FCC 15.105 (a):
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 21 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 6.4.4 Test mode sticker The device label is located on the reading unit housing. By setting the DIP-switch 3 the test mode is activated. The test mode read or write is set with the DIP switch 4. The selection oft he antenna port is changed by the DIP switched 1 and 2. Further functions see section DIP switch. DIP Switches DIP /Ant Port: 1 1 2 3 4 3 2 4 off on on on off on Testmode on/off 3 off: Start Antenna Tuning 3 on: Off-Read / On-Write HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 22 WE GENERATE SOLUTIONS 7. Installation Customer manual LFM 4x Reader RFID Follow the basic safety instructions in the chapter Safety instructions. 7.1 Safety instructions The unit is exclusively designed for indoor use in an industrial environment. The unit may only be installed indoors with a temperature and humidity level with in the range of the specified technical module parameters. Never use the unit near or in water. Never pour liquids of any type over the unit. However, if the unit should still come in contact with liquid, disconnect it and have it checked by a technician. Do not install the device near heat sources such as radiators, heat regis- ters, stoves or other devices (including amplifiers) that generate heat. Do not install the unit in a flammable environment. Never expose the device to extreme temperature fluctuations, since con- densation otherwise develops inside the unit and causes damages. Do not install the device in the vicinity of voltage lines or other power lines with which they could collide (for example, drilling), which could result in serious injuries or even death. The device (especially the antenna) should not be installed in the immediate vicinity of electrical equipment such as medical devices, monitors, telephones, TV sets and magnetic disks, and metal objects. This could result in reduced read and write ranges. Never use the unit in explosive areas (such as paint warehouses). Do not use the device in areas where it is exposed to vibrations or shocks. The installation location must be adequately illuminated during the installation. Never install the unit during a lightning storm. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 23 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Make sure that the installation meets the requirements of the FCC
(country specific) for human exposure to radio frequencies. 7.2 Qualified installation personnel The unit must only be installed by specially trained personnel. If you have any doubts about the qualifications, please contact the manufacturer. If the unit is operated by untrained personnel, the reading device and or connected devices may be damaged. 7.3 Unpacking The LF reading device and the accessories can be packed customer-dependent in clean room conditions. In order to maintain this condition, the devices must be unpacked in clean room conditions. The packaging material consists of cardboard and foil. Dispose of these materials separately under the respective regulations of your country. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 24 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 7.4 Mounting the device Dimensions The mounting surface must be stable, non-flammable, dry and clean. If necessary, clean it before you install the device. Only use components, cable and mounting materials provided by HERMOS. Only mount the components at the designated locations and make sure that the operating and ambient conditions specified in the technical data are always maintained. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 25 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 7.5 Installing the antenna When installing the antenna, observe the required reading and writing ranges. The reading device can only be used properly if the transponder is located within the reading and writing range of the antenna. 7.5.1 Positioning the antenna The removal and alignment of the transponder tot he antenna is critical to ensure reliable reading and writing. The following diagram displays the optimum alignment and position of the transponder to the antenna. After positioning, the antenna must be tuned to the ambient conditions. The tuning function can be started with the DIP switch 4. Transponder parallel to the antenna axis:
Transponder vertical to the antenna axis:
Transponder is outside the antenna range Transponder is within the antenna range Transponder is outside the antenna range Transponder is within the antenna range HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 26 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 7.5.2 Rod Antenna M dimensions Art.Nr. (HRF.A.LF.SM.SS.15) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 www.hermos.com 27 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 7.5.3 Connecting the antenna Connect the antenna at the antenna connection at the rear of the reading unit. Observe the label here. Use the antennas and antenna cable from the manufacturer to ensure optimum reading and writing ranges. 7.6 Power Supply The device can be connected to the systems internal power supply or an external power supply. There are risks if the device is supplied with the incorrect voltage. Only use cables, plugs and adapters from the manufacturer. Observe power ratings provided in the technical data. PIN Signal 1 2 3
+24V DC 0 V GND If the device is connected to the power supply, the power LED lights up. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 27 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 7.7 DIP-switch Test mode can be activated via the 4 DIP switches on the device. In test mode, a continuous reading operation is performed at the set antenna port and the result of the reading operation is displayed on the status LED. The test mode is activated by setting DIP switch 3DIP switch 4 can be used to select between test reading and test writing The selection of the antenna port is changed using the DIP switches 1 and 2. Switch Function 1 2 3 4 Antenna connection selection off, off Antenna connection 1 off, on Antenna connection 2 on, off Antenna connection 3 on, on Antenna connection 4 off: Operation mode on: Activated test mode DIP 3 off: Deactivated test mode off->on Start Antenna Tuning DIP 3 on: Activated test mode Selection of the test function:
off = Read, on = Write HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 28 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 7.8 RS232 connection The serial interface is implemented as a Sub-D plug connector (9-pin). A serial connection line (1:1 circuit) can be used. PIN 1 2 3 4 5 6 7 8 9 Signal NC
(Optional GND) TxD RxD NC GND NC NC NC NC
(Optional +5V) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 29 WE GENERATE SOLUTIONS 8.Commissioning 8.1 Operating conditions Customer manual LFM 4x Reader RFID The following requirements must be fulfilled for smooth device operation. 1. The operating temperature must be within the scope of the values specified in the technical data. The device must be connected to the power supply (provide PoE is not used). An antenna must be properly connected to the reading device. A transponder must be within the reading and writing ranges of the connected antenna. For normal operation, deactivate test mode after installation. (All DIP switches off). 2. 3. 4. 5. 8.2 The serial interface parameters The following settings of the serial interfaces are set on delivery. The baud rate can be changed in the SECS protocol with the parameter 0x01. If you want to change the baud rate in the ASCII protocol, then please contact the manufacturer HERMOS. Signal Baudrate 19200 Datenbits Stoppbits Paritt 8 1 ASCII:
Even SECS/HSMS: None HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 30 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 8.3 Parameter of the ethernet interface The unit is connected to the customer network via a 10/100BaseT Ethernet interface. The DHCP (Dynamic Host Configuration Protocol) is activated on delivery. If there is not a DHCP server available in your network, a random IP address is set from the Zero- Conf range (169.254.0.0/16) and operations must still be performed to obtain an IP address. If an IP address could be obtained or with a static IP address, the device can be connected via TCP / IP port 3241 in the delivery state. The HERMOS DeviceDiscoverer is available for configuring the network setting. 8.3.1 Change networksettings with DeviceDiscoverer HERMOS components can be found in the LAN network and settings can be easily changed using the DeviceDiscoverer. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 31 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 1. 2. 3. Select your network interface if you have several options on your PC. Your network is automatically scanned for all HERMOS reading devices using the Search Devices button. Select the desired reading device in the list to open the network settings. Here, you can edit the network settings and apply them to the reading device by pressing the respective button. Use HERMOS if you are asked to enter a password!
After parameters are changed, the reading device reboots and can be read in using Search Devices. CAUTION Changing network settings generally cause the reading device to reboot. This closes an existing HSMS host connection. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 32 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 8.3.2 Firmware update with DeviceDiscoverer Firmware updates can also be performed using the HERMOS DeviceDiscoverer. Start the tool with administrator rights and scan the network for all HERMOS devices. To do an update, mark the desired reading device and select Firware Update. Use HERMOS if you are asked to enter a password!
Click the "Firmware Update" button to open the new Firmware Download window for the selected reader. It is usually not necessary to open the download connection as this happens automatically. Otherwise, pressing the Connect button will open the download connection. Select the new firmware file using the load image button. Start the download process. Wait until the Download Finished message appears. 1. 2. 3. 4. CAUTION During the download process, do not disconnect the power supply or interrupt the network connection. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 33 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 8.3.3 Test Device with DeviceDiscoverer This feature is not yet supported by all HERMOS readers and is only available for the LFM4x as of software version V1.5. Readers can also be tested with the HERMOS "Device Discoverer" if you have one support feature. Start the tool with administrator rights and search for the HERMOS device under test in the network. Select the desired reader and select the "Device Test" button independently of your interface. A further "Device Test" view is opened with which the addressed reader can be tested via the UDP protocol without having to disconnect any existing TCP / IP connection. Expert Mode:
In the "Expert Mode" tab you can select from a list of test commands and send this after any modification. The Trace window below shows all traffic generated when testing with UDP. The success code of the response message is displayed in the status bar at the bottom left. Below is the structure of the UDP action commands to own test actions on the reader to be able to define. Depending on the command, the head number and data may be optional data elements Structure of the request message:
Len Actionr CMD 0x02 0x02 0x02 0x04 0x04 0x00 0x01 0x02 0x03 0x04 0x4E (N) 0x56 (V) 0x53 (S) 0x46(F) 0x50(P) optional Headnr 0x01 0x01 0x04 0x05 0x49(I) 0x01 0x05 0x06 0x58(X) 0x01 0x10 (auto tune) 0x02, 0x08 opt. Daten Description 0x1A (Parnr.) Get Parameter Head 0x01 Par. 0x1A 0x07, 0x03 Trigger Readerreset Get Softwareversion Get UDP Revision Set Parameter Head 0x01 Par. 0x07 Value 0x03 Trigger Tuning (0x10 auto tune) Head 0x01 Trigger Read Page 0x02 Length 0x08 at Head 0x01 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 34 WE GENERATE SOLUTIONS Structure of the response message:
Customer manual LFM 4x Reader RFID Lnge Actionr CMD 0x03 0x00 0x6E (n) Success-Code opt.Headnr 0x00 (ok) opt. Daten 0x12 0x01 0x76 (v) 0x00 (ok) 0x04 0x02 0x73(s) 0x00 (ok) 0x53, 0x57,, 0x30 0x01 0x06 0x03 0x66(f) 0x00 (ok) 0x01 0x1A, 0x0F 0x03 0x03 0x66(f) 0x36 (invalid parnr) 0x04 0x04 0x70(p) 0x00 (ok) 0x01 0x04 0x04 0x70(p) 0x37(invalid value) 0x05 0x05 0x69(i) 0x00 (ok) 0x01 0x03 0x05 0x69(i) 0x35 (invalid) 0x0D 0x06 0x78(x) 0x00 (ok) 0x01 0x04
(Tuningwert) 0x02, 0x310x38 0x03 0x06 0x78(x) 0x34 (No Tag) Erklrung ResponseTriggered Reset Response Get Softwareversion Response Get UDP Revision 0x01 Response Get Parameter Head 0x01 Par 0x1A Value 0x0F Response Get Parameter Error 0x35 Invalid parnr Response Set Parameter Head 0x01 Response Set Parameter Error 0x37 Invalid value Response Tuning Head 0x01 Wert 0x04 Response Tuning Error 0x35 Invalid Value Response Read Head 0x01 Page 0x02 Data 0x310x38 Response Read Error 0x34 NoTag A success code of 0x00 in the response message indicates the correct execution of the UDP action commands, otherwise an error has occurred. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 35 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Parameters:
In the "Parameters" tab you can choose from a list of parameters that can be read and written. CAUTION When setting and reading parameters, it must be carefully considered which communication protocol is currently set. Some parameters are defined differently in different protocols. LF Module:
In the register "LF Module" a test reading can be carried out. One or more pages of a multipage transponder can be read out. The success code of the triggered reading is displayed in the status bar at the bottom of the window. Via a scan, the first page of every readable 134.2 kHz LF transponder is read out and displayed. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 36 WE GENERATE SOLUTIONS 9. Operating 9.1 Operating personnel Customer manual LFM 4x Reader RFID The device should only be operated by specially trained personnel. If you have any doubts about the required qualifications, please contact the manufacturer. The operation of the device without special expertise can result in damages to the device or on connected devices. 9.2 Protocol change 9.2.1 General To communicate with a connected host system, the reader supports ASCII or SECS /
HSMS protocols. The protocol selection takes place by means of automatic protocol recognition. The currently set protocol is displayed on the status LED during the boot process. SECS: The red LED goes on briefly after self test ASCII: The yellow LED goes on several times 9.2.2 Automatic protocol detection The reader automatically adjusts to the protocol used by checking and evaluating the first message after a reset. The interface is changed accordingly when the protocol is changed and reinitiali- zed. This process can take several seconds. Already sent messages are lost. The newly recognized protocol is used for further communication. A renewed change is only pos- sible after another reset. Automatic protocol detection can be disabled by setting parameter 98 (0x62). If the reader receives undefined or random characters, this may result in an accidental protocol change. Automatic protocol detection can be deactivated in parameter 98 (0x62). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 37 WE GENERATE SOLUTIONS 9.3 Addressing the antenna port Customer manual LFM 4x Reader RFID The reader LFM 4x is equipped with 4 antenna ports. Each of these ports has its own antenna tuning with which the connected antenna is tuned to the ambient conditions. In the set protocol, the read or write commands are always executed by port. The 4 antenna ports from 1 to 4 are numbered consecutively and are addressed accordingly in the logging command. In the ASCII protocol, the reader ID decides on the selection of the antenna port. The reader ID (1 to 4) responds to the respective antenna port 1 to 4. Depending on the Factoryparameterset, it is possible to select the value range of the reader ID from 0 to 3 or from 1 to 4. In the SECS protocol, the target ID is used to select the antenna port: Target ID 01 to 04 responds to the respective antenna port 1 to 4. For customer-specific solutions, another reader (eg HFS ESN) can be connected to the RS232 interface. This reader is then used to communicate via the Target ID 05 or Reader ID 05. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 38 WE GENERATE SOLUTIONS 9.4 Customer Factoryparametersets Customer manual LFM 4x Reader RFID The reader LFM 4x can be delivered with a few Factoryparametersets. The settings of the Factoryparameterset is part of the factory settings and can only be changed by Hermos. If customer needs another Factoryparameterset setting, please ask Hermos for the necessary steps. The installed Factoryparameterset can be read by parameter 64 (use command G164). Factoryparameterset 0: (standard ASC-I1 mode) The antenna will be addressed by the ReaderID or TargetID 1 to 4. At the rs232 connector a HFS ESN reader is connected and can be adressed by ReaderID 5. For SECS protocol there is no MID area defined. Factoryparameterset 1: (standard ASC-I1 mode) The antenna will be addressed by the ReaderID or TargetID 1 to 4. For SECS protocol there is no MID area defined. The rs232 connector can be used for serial host communication. Factoryparameterset 2: (standard ASC-I1 mode) The antenna will be addressed by the ReaderID or TargetID 1 to 4. For SECS protocol the default MID area of 2 pages / 16 characters is defined. The rs232 connector can be used for serial host communication. Factoryparameterset 3: (ASC-W1 mode) The antenna is addressed by the ReaderID 0 to 3, or TargetID 1 to 4. For SECS protocol there is no MID area defined. The rs232 connector can be used for serial host communication. For the TCP/IP communication the complete end packet of the ASCI-I1 protocol will be transmitted (end character and 4 bytes checksum). P-command: The parameter value will be interpreted as hexadecimal value. The additional F-command can be used to deliver the parameter value with hexadecimal interpretation. X/R/W-command: The page value will be interpreted as hexadecimal value. Errors will be send with the command E. With default settings a confirmation has to be send. The additional B-command can be used for signal the detection of an object. Factoryparameterset 4: (standard ASC-I1 mode) The antenna will be addressed by the ReaderID 0 to 3 or TargetID 1 to 4. For the SECS protocol, the standard MID range of 2 pages / 16 characters is defined. The RS232 port can be used for serial host communication. Factoryparameterset 5: (standard ASC-I1 mode) The antenna will be addressed by the ReaderID 0 to 3 or TargetID 1 to 4. For the SECS protocol, the standard MID range of 2 pages / 16 characters is defined. The RS232 port can be used for serial host communication. This mode supports the 24 volt I / O module with 6 sensors and 8 outputs. The two additional sensors are represented by an extended range for ReaderID or Portnumber PTN. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 39 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10. ASCI-I1 Communication protocol 10.1 Structure of the communication protocol The communication is carried out via ASCII packets. After each command to the reading device, a specific reply is transmitted. We recommend waiting for this reply before transmitting a new command. 10.2 Packet content Each message packet consists of a packet header (header = 3 characters), the message data (2 or more characters) and the packet end. Packet header Message data Packet end Packet header The packet header contains a start character and the message length. The message length consists of 2 hexadecimal bytes and defines the number of characters in a message. Packet header Start character Length 1 (high byte) Length 2 (low byte) Start Start character (ASCII character S) Length 1 High byte of the message length (ASCII character 0-F) Low byte of the message length (ASCII character 0-F) Length 2 Advanced ASCII-format:
The advanced ASCII format is defined for ASCII messages whose message length exceeds 255 characters. The packet header contains two start characters and the message length. The message length consists of 4 hexadecimal bytes and defines the number of characters in a message. Packet header Start 1 Start 2 Length 1 Length 2 Length 3 Length 4 Start 1 Start 2 First start character
(ASCII-character S) Second start character (ASCII-character X = advanced ASCII protocol) Length 1 High byte of the message length (ASCII-character 0-F) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 40 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Length 2 Length 3 Length 4 Message data Byte packet length (ASCII character 0-F) Byte packet length (ASCII character 0-F) Low byte of the message length (ASCII character 0-F) The message contains a command character, a target or source address, the number of the antenna port (head) and the actual message data. The number of the antenna port is not required for all messages. Message data Command Address Data Command The command is defined by an ASCII character. (See protocol commands) Address Target/source address (ASCII characters 0, 1, ) *
The definition of the message data depends on the protocol command. Data
* Depending on Factoryparameterset, the readers are addressed via the address 0 ... 3 or 1 ... 4. Packet end The end of the packet contains an end character and a checksum consisting of 4 characters. Packet end End character Checksum 1 Checksum 2 Checksum 3 Checksum 4 End character ASCII end character <CR> (hex 0x0D). Checksum 1 High byte XOR logic of all data (packet header, data and end character).
(ASCII character 0F) Checksum 2 Low byte XOR logic of all data (packet header, data and end character).
(ASCII character 0F) Checksum 3 High byte addition of all data (packet header, data and end character).
(ASCII character 0F) Checksum 4 Low byte addition of all data (packet header, data and end character).
(ASCII character 0F) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 41 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID The checksum is not necessary when using the TCP/IP interface (No transmission). The end character is only transmitted. If the device is operated in ASC-W1 mode, the complete end packet is transmitted (end character and 4 bytes checksum). 10.3 Data elements The data elements that are used by default ASCII messages, which are described in the message details section, are defined in this section. Tuning value 2 Byte The tuning value is a set value for the optimal antenna tuning. For optimum read and write ranges, the value is automatically determined by the reader. The value is measured in 16 steps (0-F). He can also be targeted. Example:
automatic tuning from the reader manual tuning 0x00 manual tuning 0x0F 08 10 1F CMD 1 Byte Command of the message, see table in Chapter Commands. Data 16 Bytes The data is represented in HEX format by 2 ASCII characters. The data always includes every 8 bytes of the corresponding page of the transporter. Example:
Transponder data in ASCII-Format Transponder data in HEX-Format Data in message 12345678 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 3132333435363738
(8 bytes)
(16 ASCII-characters) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 42 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Output Index 1 Byte The Output Index defines the index of the output of a Readerhead that is addressed. Each Readerhead has 2 LEDs. Example:
1 2 3 4 LED1 of the port LED2 of the port red status LED yellow status LED Output State Output State 4 Bytes 4 Bytes The data element shows or sets the current status of the outputs. The Data Element Output State includes the status of each output on the reader. The status is displayed as 1 byte for each sensor. 0 1 2 3 4 Switch off the output permanently Switch on the output permanently output flashes with approx. 1 Hz output remains unchanged output flashes with approx. 2 Hz Parameter No. 1 Byte The number of the parameter is displayed as an ASCII character (1 byte) in HEX format. Example:
Parameter 1 Parameter 2 Parameter 15 1 2 F Parameter Value 2 Bytes With single-digit parameter numbers from 0 to F, the actual parameter value can be decimal or hexadecimal depending on the mode. In the standard ASC-I1 mode, the data element displays the value of a parameter using 2 ASCII characters (2 bytes) in decimal format (00 bis 99). Example:
In ASC-W1 mode the data element indicates the value of a parameter by means of 2 ASCII characters (2 bytes) in hexadecimal format (00 to FF). Example:
Value 45 (decimal) 2D(hexadecimal) Value 45 45 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 43 WE GENERATE SOLUTIONS Reader-ID Output State Customer manual LFM 4x Reader RFID 1 Byte 4 Bytes The reader ID defines the address of the antenna port. The reader LFM 4x can be read at all 4 antenna ports (1-4). The antenna port is selected via the reader ID and is continuous. In ASC-W1 -mode the 4 antenna ports with the reader ID 0 to 3 are addressed. General messages also possible at address F (HF). Value range of 1-4, or 0-3. Response-Code 4 Bytes This feature is not required for the individual device. This code is always 0000. Page 1 Bytes The page of the transponder for a read / write operation is defined by 2 ASCII characters
(2 bytes) in decimal format Example:
Page 1 01 Page 10 10 Page 17 17 If the device is operating in ASC-W1 mode, the page should be interpreted in hexadecimal form: The page of the transponder for a read / write operation is defined by 2 ASCII characters
(2 bytes) in hexadecimal format. Example:
Page 1 01 (81 if page is locked) Page 10 0A (8A if page is locked) Page 17 11 (91 if page is locked) Read/Only F0 Read/Write F1 Serial number 4 Bytes Contains 4 byte of the serial number. The serial number is also on the adhesive label of the device. Example:
1707HAG04660 complete serial number Decimal 04660 (the last 5 characters of the complete serial number) Hexadecimal serial number 1234 The gateway ID is the last two digits and has the value 0x34 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 44 WE GENERATE SOLUTIONS Software version Customer manual LFM 4x Reader RFID 16 Bytes The data item contains the software version currently used in the reader. The version string is displayed with up to 16 characters. Example:
4C464D3449312E35
(LFM4I1.5) hex-String Timeout 2 Bytes The data element Timeout defines the period of time that elapses until the LEDs are switched off. The timeout is defined in hexadecimal notation. When the timeout expires, the LED turns off. Example:
... permanently on 00 01 bis FF ... 1 s bis 255 s Timeout 10.4 Protocol Commands Read:
Command Description Read Data Automatic Read X R Write:
Command Description W Write Data HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 45 WE GENERATE SOLUTIONS Device-Settings:
Command Description Customer manual LFM 4x Reader RFID G F P N e E H V L l J Query Parameter Query Parameter (Device is operated in ASC-W1 mode) Set Parameter Reset Error message Error message (Device is operated in ASC-W1 mode) Heartbeat Software-Version Lock side of a transponder Coordinate RF-modules Querying the coordination of the RF-module In- and Output:
Command Description O Q A B Set Output Query Output/Input State Sensor event: Sensor removed Sensor event: Sensor detected (Device is operated in ASC-W1 mode) For customer-specific device variants (->Factoryparametersets), another reader can be connected to the RS232 interface. The commands specified for this device are not part of this documentation. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 46 Customer manual LFM 4x Reader RFID Reader-ID 1 Byte Page 2 Bytes WE GENERATE SOLUTIONS 10.4.1 X - Read data Host Device CMD X Device Host CMD x Reader-ID Page Data 1 Byte 2 Bytes 16 Bytes The data element page can have the following values:
Page Description 01 17 Read # page 98 99 Read multiple pages to the end character or a blank character 1) Read out all transponder data 1) E or F in ID, Bit 03 of the read ID In ASC-W1 mode, the data element page can have the following values:
Page Description 01 11 Read page # of a multipage transponder F0 F1 00 Read/Only transponder Read/Write transponder Read the first page of all transponder types HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 47 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID If there is no transponder in the reading range of the antenna, the reader repeats the reading function several times before an error message is sent. The number of repetitions is defined in parameter 4 (r / w maxrepeat). If reading is still not possible, the reader sends the error message no tag (4) to the host after the repetitions have been carried out. No confirmation is expected from the host. For a multipage read request (98 or 99), the protocol is retried. At the end of reading, the reader sends an additional packet. If the sensor check is activated (parameter 1: readmode), the assignment of the external input is checked before the initiation of a read process by the host. The reading process is only started if the sensor is occupied, otherwise the error message no tag (4) is sent. 10.4.2 R Automatic read By assigning the external input, an automatic read operation can be triggered. The command R sends the read data to the host. The host then has to confirm the message. Depending on the setting of the reader (parameter 1: readmode), the reader reads the following pages:
Read Mode:
0 Reading the page defined in parameter 2 (readpage) 1 sequential reading of a transponder to the end character
(E - end character or F empty) in ID bit 0 ... 3 2 Reading the entire transponder (all pages) Device Host CMD Reader-ID Page Data R Host Device CMD r 1 Byte 2 Bytes 16 Bytes Reader-ID 1 Byte HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 48 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID When reading several pages (par. 1: readmode tag or everything) the command is repeated for each read page. The last package contains the command R and the reader ID. The host expects a confirmation of the read data. If there is no confirmation from the host, the command is repeated. (par.5: RS232 repeat time, par.6: RS232 maxrepeat). If a reading is not possible, the reader automatically repeats the reading with the set parameters. (par.3: r / w delay time, par.4 r / w maxrepeat). If no reading is possible, the reader sends the error message no tag (4) to the host. The delay time for the presence sensor can be set (parameter 0: sensor delay). An automatic reading is only possible if all messages to be confirmed have been confirmed by the previous reading or the waiting time (par.5: RS232 repeat time, par.6: RS232 maxrepeat) has elapsed after the last transmission. 10.4.3 W - Write data The command W starts writing a defined data area of a transponder. If there is no transponder in the write range of the antenna, the reader sends an error message (error 4 - no transponder). Host Device CMD Reader-ID Page Data W Device Host CMD w 1 Byte 2 Bytes 16 Bytes Reader-ID 1 Byte If the describing of the tag fails, the reader repeats the writing operation several times before sending an error message. The number of repetitions is defined in parameter 4 (r / w maxrepeat). If writing is still not possible, the reader sends the error message no tag (4) to the host after the repetitions have been carried out. If the sensor check is activated (parameter 1: readmode), the assignment of the external input is checked before the start of the write process by the host. The write process is started only when the sensor is busy, otherwise the error message no tag (4) is sent. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 49 WE GENERATE SOLUTIONS 10.4.4 G Query parameter Customer manual LFM 4x Reader RFID With the command G the values of all public parameters of the device can be queried. Host Device CMD G Device Host CMD g Reader-ID 1 Byte Reader-ID Parameter No. Parameter Value 1 Byte 1 Byte 2 Bytes The reader sends an individual protocol packet for each available public parameter. After the last parameter, the reader sends a last packet including the command g and the reader ID. From the list of public parameters only the parameter 0 to 7 and parameter F will be send. The values returned for the data item parameter value in the response are decimal values
(00-99). The values for the data item Parameter No. are hexadecimal values (0-F). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 50 WE GENERATE SOLUTIONS 10.4.5 F Query parameter Customer manual LFM 4x Reader RFID The command F can be used to query the value of a public parameter of the device. Host LF Device CMD Reader-ID Parameter No. F Device Host CMD f 1 Byte 1 Byte Reader-ID Parameter No. Parameter Value 1 Byte 1 Byte 2 Bytes The reader sends an individual protocol packet for the requested public parameter. The values returned in the response for the data elements parameter number and parameter value are each hexadecimal values (0-F or 00-FF). In the case of two-digit hexadecimal parameter numbers (Parameter No.), the parameter number and the parameter value double-digit hexadecimal are also used in the response. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 51 WE GENERATE SOLUTIONS 10.4.6 P Set parameter Customer manual LFM 4x Reader RFID The command P can be used to change the value of individual parameters. After a parameter has been successfully changed, the reader sends a confirmation message. Host Device CMD Reader-ID Parameter No. Parameter Value P Device Host CMD p 1 Byte 1 Byte 2 Bytes Reader-ID 1 Byte Depending on the Factoryparameterset selected, the data elements parameter number and parameter value must be interpreted differently. For single-digit hexadecimal parameter no. the following interpretations must be observed:
In the standard ASC-I1 protocol mode the data element Parameter Value with decimal values
(00-99) has to be used. The values for the data item Parameter No. are hexadecimal values
(0-F). Only in ASC-W1 mode (Factoryparameterset 3) the data elements Parameter No. and Parameter Value have to be used as hexadecimal values (0-F or 00-FF). For two-digit hexadecimal parameter numbers (Parameter No.), the parameter value must always be sent in two digits hexadecimal. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 52 WE GENERATE SOLUTIONS 10.4.7 N Reset Customer manual LFM 4x Reader RFID The command N performs a reset of the hardware/software of the reader. After performing the reset operation, the device sends a confirmation message. Host Device CMD N Device Host CMD n Reader-ID 1 Byte Reader-ID 1 Byte After a hardware reset, a confirmation (n0) is sent to the host. If TCP / IP is used as the interface, the host will not receive an acknowledgment, because an existing TCP/IP connection is interrupted by the reset. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 53 WE GENERATE SOLUTIONS 10.4.8 e Error message Customer manual LFM 4x Reader RFID This message is only available in standard ASC-I1 mode!
If an error occurs the device will send an error message with the respective error code. Device Host CMD e Reader-ID 1 Byte Error ID 1 Byte Further information about error codes and the corresponding corrective measures can be found in the chapter Error Codes. 10.4.9 E Error message This message is only available in ASC-W1 mode. If there is an error, the device sends an error messa- ge with the appropriate error code to the host. The reader expects a confirmation of the error message. If there is no confirmation from the host, the command is repeated. (Par.5: RS232 delay time, par.6: RS232 maxrepeat). Device Host CMD E Reader-ID 1 Byte Error ID 1 Byte More about error codes and the corresponding corrective measures can be found in the chapter Error Codes. Host Device CMD e Reader-ID 1 Byte HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 54 WE GENERATE SOLUTIONS 10.4.10 H Heartbeat Customer manual LFM 4x Reader RFID The command H sends a heartbeat request to the reader. The reader responds with its serial number and a response code. Host Device CMD H Device Host CMD h Reader-ID 1 Byte - also Reader ID F allowed Reader-ID Serial number Response-Code 1 Byte 4 Bytes 4 Bytes The heartbeat function can be performed for all 4 antenna ports (1-4). If another reader is operated as a customer variant on the RS232 port, a heartbeat can be sent to the external reader via reader ID 5. The response code is part of the protocol but is not used for this device. The response code is always 0000. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 55 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.11 V Query software version The command V is used to query the software version of the device. Host Device CMD V Device Host CMD v Reader-ID 1 Byte Reader-ID Software version 1 Byte 16 Bytes The 8 characters of the software version are represented by 16 ASCII characters. Each character is described in hex format and transmitted by 2 ASCII characters. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 56 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.12 L - Lock data area A single page of a multipage transponder can be disabled. The page can still be read, but not rewritten. The process cannot be reversed. Host Device CMD Reader-ID 1 Byte L Device Host CMD L Reader-ID 1 Byte Pages 2 Bytes If the lock of the transponder page fails, the reader repeats the procedure several times before an error message is sent. The number of repetitions is defined in parameter 4 (r / w maxrepeat). If writing is still not possible, the reader sends the error message no tag (4) to the host after the repetitions have been carried out. If the page was already locked, a positive confirmation will be sent (same as the first block). If the sensor check is activated (parameter 1 readmode), the assignment of the external input is checked before the blocking process is started by the host. The locking process is only started when the sensor is occupied, otherwise the error message no tag (4) is sent. Locking a page cannot be reversed. This page is permanently write protected. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 57 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.13 I Adjust RF module It is necessary to adjust the RF module in ordert to adapt an antenna tot he ambient conditions optimally. The tuning achieves an optimal read / write range for the present installation environment. Tuning is performed one at a time for each antenna port and the determined tuning value is stored for each antenna. For optimal results, the vote should be automatic, but the voting value can also be set manually. Host Device CMD Reader-ID Tuning Value I Device Host CMD i 1 Byte 2 Bytes Reader-ID 1 Byte To start the auto-tuning process, select the value 08. Example:
If the reader can not determine the appropriate calibration, the error 5 - Invalid is sent instead of the confirmation. I108 automatic tuning of antenna 1 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 58 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.14 J RF module Queries the vote The command J can be used to query the tuning values of the individual antennas. Each antenna port has its own tuning value. Host Device CMD J Device Host Reader-ID 1 Byte CMD Reader-ID Tuning value j 1 Byte 2 Bytes The tuning value is a set value for the optimal antenna tuning. For optimum read and write ranges, the value is automatically determined by the reader
(I-message). The value is measured in 16 steps (0-F). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 59 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.15 A Sensor event object removed The message of sensor events can be activated in the parameter Watch-Port (par. 07). If this is activated, the reader reports every drop of the external sensor. The sensor message must be confirmed by the host. Reader-ID 1 Byte Host Device CMD A LF Lesegert Host CMD a Reader-ID 1 Byte The sensor event is detected after an adjustable delay time (par. 0 Sensor Delay). During the delay time, the sensor signal must be stable. In parameter 1 Read Mode the sensor can be deactivated. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 60 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.16 B Sensor event object detected The message of sensor events can be activated in the parameter Watch-Port (par. 07). If this is activated, the reader reports any recognition of the external sensor. The sensor message must be confirmed by the host. Host Device CMD B Device Host CMD b Reader-ID 1 Byte Reader-ID 1 Byte The assignment of the external sensor results in an automatic reading and is not sent as a sensor event in standard ASC-I1 mode. In the ASC-W1 mode, however, a sensor event B is present. In parameter 1 Read Mode the sensor can be deactivated. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 61 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.17 O Set output The command O can be used to set the state of the outputs. The status of all outputs is changed in a message. In the current version, the value of the data element Head-ID always has the value 1 for the outputs. Host Device CMD Reader-ID Head-ID Output Index Output State Timeout*
O 1 Byte 1 Byte 1 Byte 1 Byte 2 Bytes Device Host CMD o Reader-ID 1 Byte Head-ID 1 Byte
The specification of a time duration (timeout) is optional. Example:
permanently switch on LED 1:
>> O111100
<< 011 Turn red status LED on for 10 seconds:
>> O11310A
<< 011 The number of available outputs depends on the reader version used. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 62 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 10.4.18 Q Querying the status of the inputs and outputs The Q command can be used to query the current status of all outputs. The status of the outputs is queried in a message. In the current version, the value of the data element Head-ID always has the value 1 for the outputs. Host Device CMD Q Device Host Reader-ID 1 Byte Head-ID 1 Byte CMD Reader-ID Head-ID Output Index Output State LED1 Output State LED2 q 1 Byte 1 Byte 1 Byte 1 Byte 1 Bytes Status LEDs Port 1 LED1 (2 = flash), LED2 (1 = on) Example:
>> Q11
<< q1121 The status of all 4 (The number of sensor states may vary between 4 and 6, depending on the custo- mer mode.) input sensors can be queried via head ID 0. In this case, the answer contains the 4 (The number of sensor states may vary between 4 and 6, depending on the Factoryparameterset.) sensor states instead of the 2 output states. Example:
>> Q10
<< q100000 Status of all 4 sensors HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 63 WE GENERATE SOLUTIONS 10.5 Parameter Customer manual LFM 4x Reader RFID The parameters 0, 1, 2 and 7 are only valid if the reader is equipped with a corresponding I / O module and provides one input per antenna port.
*): Since software revision V1.5 some parameters are implemented for each antenna port. Addressing of the parameter takes place via the reader ID of the message. In this realisation, the parameter is present once per antenna port. If no parameter arrays should be used, please ask the manufacturer (parameter 63)!
The data element Parameter No. can have the following values. List of public paramters:
Nr.
(dez) Nr.
(hex) Parameter name Description Sensor delay 0x00 0 1 0x01 Read mode Delay time for the presence sensor. 01 .. 99 (0,1 Sekunden) Default: 10 (1 second) Realisation: a separate parameter for each port *) Read mode for reading automatically started by external input. 00 - read only one page 01 - read until the end character or empty character2) 02 - read all pages 10 - read only one page with previous sensor Check1) 11 - read until the end character / empty character with previous sensor check 1) 2) 12 - read all pages with previous sensor Check1) 99 - Disable sensor 1) If the Sensor Check (first byte = 1) is activated, the assignment of the potential-free input is checked before initiating a read / write process. When used, the read / write process is started, otherwise the error message NOTAG is sent. 2) E or F in ID bits 0...3 of the read ID Default: 00 (read only one page) Realisation: a separate parameter for each port *) Page for readmode 00. 01 First page of each transponder 02.. 17 Side of a multipage transponder Default: 01 (read first page) Realisation: a separate parameter for each port *) Time between two read / write attempts. 01 .. 99 (0,1 s) Default: 05 (0,5 seconds) Realisation: a separate parameter for each port *) LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 64 0x02 Read page 2 3 0x03 r/w repeat time HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 0x04 4 r/w max repeat 5 0x05 RS232 repeat time Max. number of read / write attempts. 01 .. 99 Default: 05 Realisation: a separate parameter for each port *) If no confirmation message was received from the host, the device waits for this time before sending another message. The number of repetitions is defined in parameter 6 (RS232 max repeat). 01 .. 99 (0,1 s) Default: 45 (4,5 seconds) 6 0x06 RS232 max repeat If an acknowledgement is not sent by the host, the device repeats the message according to the set value. Only then is an error message sent. 00 - endless 01 .. 99 - Number of attempts Default: 3 7 0x07 Watch port Activates / deactivates the event message to the host that the dry contact (external output) has been opened (Bit0). Bit0 (=0x01) reporting of contact has been opened:
0 - deactivated 1 - activated Default: 1 Realisation: a separate parameter for each port *) F 0x0F Reader address Address of the first antenna port (0 ... E) Default: 1 For ASC-W1 mode the following additional parameters are public:
Nr.
(dez) Nr.
(hex) Parameter name Description Read page 0x02 2 7 0x07 Watch port Page for readmode 00. 00 First page of each transponder 01 17 Side of a multipage transponder Default: 00 (read first page) Realisation: a separate parameter for each port *) Activates / deactivates the event message to the host that the dry contact (external output) has been opened (Bit0) or closed (Bit1). Bit0 (=0x01) reporting of contact has been opened:
0 - deactivated 1 - activated Bit1 (=0x02) reporting of contact has been closed:
0 - deactivated 1 activated Default: 1 Realisation: a separate parameter for each port *) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 65 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 8 9 10 11 12 13 0x08 0x09 0x0A 0x0C 0x0D Fieldstrength Parameter is without further function. Range: 00-01 Default: 1 Charge time Verify Transponder charging time in milliseconds. Range: 00-FF Default: 32(50ms) Realisation: a separate parameter for each port *) Parameter is without further function. Range: 00-03 Default: 1 0x0B Fallout Parameter is without further function. Range: 00-03 Default: 1 RS232 repeat time Parameter is without further function. Range: 00-FF Default: 0 Noiselevel adjust Parameter is without further function. Bereich: 00-FF Default: 0 14 0x0E Sensor polarity Type of sensor signal to start an automatic read. The setting is applied for the addressed sensor. 0 read process when sensor is covered 1 read process when sensor is uncovered Default: 0 Realisation: a separate parameter for each port *) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 66 WE GENERATE SOLUTIONS 10.6 Message examples Customer manual LFM 4x Reader RFID ASCII HEX Description S 0 2 H 0 CR 2 4 3 53 30 32 48 30 0D 32*) 34*) 33*) Start character High byte message length Lowbyte message length Message first character: value Message second character: destination address End character Highbyte Checksum XOR Lowbyte Checksum XOR Highbyte Checksum Addition A 41*) Lowbyte Checksum Addition
*): With TCP / IP transmission in the standard ASC-I1 protocol, the checksum bytes are not transmitted. In ASC-W1 mode, however, they are also transmitted!
Calculation of the XOR checksum:
53 XOR 30 XOR 32 XOR 48 XOR 30 XOR 0D =
24 2 4 Calculation of the addition-checksum:
53 + 30 + 32 + 48 + 30 + 0D =
(LSB is used) 13A 3 A HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 67 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID The following examples are based on the standard ASC-I1 protocol. The range of the Reader ID is set from 1 to 4 in this case:
V Query software version
>> V1
<< v14C464D3449312E35 Command Reader-ID V 1 ASCII LFM4I1.5 I 2
(Tuning Antenna port 2) Software version 4C464D3449312E35 I automatically tune RF module (antenna port 2)
>> I208
<< i2 Commandl Reader-ID J RF module Read out tuning value (Antenna port 2)
>> J2
<< j201 Command Reader-ID Data X Read data (Reading from page 1 of the multipage transponder)
>> X101
<< x1014142434445464748 Command Reader-ID Page
(Antenna port 2)
(voting value)
(reading on antenna port 1) X 1 01 J 2 01 ASCII ABCDEFGH Data4142434445464748 R - Automatic reading on antenna port 1
<< R1013132333435363738
>> r1 Command Reader-ID Page R 1 01
(automatic reading on antenna port 1) Data4142434445464748 W Write data (Write antenna port 2, page 16 Multipage)
>> W2103132333435363738
<< w2 Command Reader-ID W 2 (Write to antenna port 2) Page 10 ASCII ABCDEFGH
(10hex = page 16dec.) Data3132333435363738 ASCII 12345678 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 68 WE GENERATE SOLUTIONS 10.7 Error Codes Customer manual LFM 4x Reader RFID ID Name Description Possible Cause Corrective action none No error none auto fail ext fail Automatic reading is not possible Execution failed, read or write operation cannot be carried out Reader is still busy with a former read or write request Wait until the previous request has ended. Reader is still busy with a former read or write request. Wait until the previous request has ended. write fail Data transfer to the tag is not possible. Reader is still busy with a former read or write request. Wait until the previous request has ended. Antenna is not connected properly Check antenna connection Antenna is not tuned Antenna tuning No readable transponder within the reading range Put the transponder in the antenna area. Check the type and function of the transponder Antenna / transponder are misaligned Check the alignment of the antenna and the transponder Antenna is damaged or too close to metal Replace the antenna, check the tuning Interference field at transmission frequency Invalid command data Check antenna environment for possible sources of interference.
(Monitors, servomotors) Check command syntax and data content Parameter is not implemented or out of range Check parameter syntax and value 0 1 2 3 4 no tag No transponder or antenna installed 5 invalid Invalid parameter or data 8 9 check Parity or checksum error void ackn unexpected acknowledge 6 unknown Unknown errors none 7 Unconfig The device is not configured Wrong reader address Wrong baud rate Check message syntax, check parameter F Reader address Check the baud rate of the serial interface (Com port) Transmission error at serial communication Check RS232 cable and connector, Check sources of interference with RS232 Serial communication is interrupted Check RS232 cable and connector, Check sources of interference with RS232 Ethernet communication is interrupted Check Ethernet cable and connector, check IP address settings Double or wrong acknowledgment Check communication settings at the host Check the page number to be written, exchange the tag for the new one A Locked Locked page cannot be written Tag is write protected HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 69 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID B Unconfig C Bad type
Msg len Maximum number of send messages has been confirmed
(RS232 maxrepeat), The terminal did not confirm within the specified timeframe Wrong transponder type Message too long or too short or not received completely
Invalid Invalid command Host system does not acknowledge the message A wrong transponder type is used (Read only or Read / Write instead of multipage) Message too long or too short or not received completely Message is longer than specified in the length byte Not all characters are transfered (Intercharacter Timeout) Unknown command was received Check availability oft he host system, Check RS232 cable and connector Ethernet cable and connector, Check IPAddress settings Check and replace transponder type Message length is longer than indicated on the length byte, Check message length and length byte Check message length, check length byte Check message syntax, Check RS232 or Ethernet connection Check message syntax HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 70 WE GENERATE SOLUTIONS 10.8 Wiring of the outputs Customer manual LFM 4x Reader RFID For readers with I / O modules, depending on the Factoryparameterset, the outputs of the respective antenna port are switched accordingly when reading. 10.8.1 ASC-W1 Mode: Reader in operation mode and sensor triggered reading Picture 1: Successful reading with instant host confirmation HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 71 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Picture 2: Successful reading with missing host confirmation Picture 3: Unsuccessful reading with instant host confirmation HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 72 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Picture 4: Unsuccessful reading with missing host confirmation 10.8.2 ASC-W1-Mode: Reader in operation mode and external triggered reading Picture 5: Successful external reading X HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 73 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Picture 6: Unsuccessful external reading X HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 74 WE GENERATE SOLUTIONS 10.9 ASCII table Customer manual LFM 4x Reader RFID DEZ HEX CTRL Code DEZ HEX CTRL Code 21 22 23 24 25 26 27 28 29 30 31 15 16 17 18 19 1A 1B 1C 1D 1E 1F
^U
^V
^W
^X
^Y
^Z
^_ NAK SYN ETB CAN EM SUB ESC FS GS RS US 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14
^A
^B
^C
^D
^E
^F
^G
^H
^I
^J
^K
^L
^M
^N
^O
^P
^Q
^R
^S
^T NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT EF CR SOH SI DLE DC1 DC2 DC3 DC4 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 75 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID DEZ HEX CTRL DEZ HEX CTRL 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 BLANK
0 1 2 3 4 5 6 7 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 8 9
A B C D E F G H I J K L M N O HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 76 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID DEZ HEX CTRL DEZ HEX CTRL 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 P Q R S T U V W X Y Z
a b c d e f g 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F h i j k l m n o p q r s t u v w x y z
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 77 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 11.SECS / HSMS Communications protocol The SECS I standard defines a communication interface that is suitable for exchanging messages between the semiconductor processing systems and a host. A host is a computer or computer network that exchanges the information with the systems to carry out the production. The standard does not define the data contained in the message. The meaning of the messages must be defined by a standard that defines the message content e.g. by the SEMI Equipment Communications Standard E5 (SECS-II). This message record describes the communication between a reading device with SECS-I and a host. The host and the RFID reading device can communicate via a RS232 interface (SECS-I) or an Ethernet interface (10/100BaseT) with HSMS protocol. The meaning of the messages is provided in the message details section in which the message content is defined. Serial communication (SECS-I):
The data is transmitted or received as a serial bit stream with 10 bits per character in a supported data rate. A standard character has a start bit, 8 data bits and a stop bit. No parity bits or other controls are used for transmitting the individual bytes. Default setting: 19200 / 8N1 Details about the data definition and the data transmission are provide in the SEMI Standard E4. (SEMI Equipment Communication Standard 1 Message Transfer SECS-I) Ethernet communication (HSMS):
The reading device functions as a HSMS server. This means that it waits for a connection request from a HOST PC (client). TCP/IP: IP-Adress xxx.xxx.xxx.xxx Port 3241 If there is a connection request from a HOST, a HSMS connection is set up and the SECS II messages defined in the message record are transmitted from the reading device to the respective HOST and vice versa. The HSMS connection remains intact until it is specifically terminated by the host or the reading device. All reading devices available in the network (LAN) can be operated from any HOST PC. A HSMS reading device, however, can no longer be connected to more than one HOST simultaneously. The network settings can be changed using a configuration tool provided by HERMOS. Each change to the network settings causes the unit to reboot and thus disconnects existing communication connections. 11.1 Structure of a message The communication structure and process is defined by the SEMI Equipment Communications Standards E4, E5 and E37 (SECS-I, SECS-II, HSMS). SECS message blocks always have a specified structure that consists of 1-4 length bytes, 10 bytes of message headers and message data. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 78 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Byte MSB Description Length Header 0 1 2 3 4 5 6 7 8 9 10 Data Checksum 11-254 255, 256 R W E Length without checksum Upper Device ID
(reader-ID) Lower Device ID
(gateway-ID) Upper Message ID
(stream) Lower Message ID
(function) Upper block number Lower block number System byte 1 System byte 2 System byte 3 System byte 4 Message data 16 Bit checksum The length contains all the bytes transmitted after the length byte with the exception of the two checksum bytes. The maximum block length allowed by the SECS-I is 254 bytes and the minimum is 10 bytes. The reverse bit (R bit) indicates the direction of the message. The R bit (MSB) is set to 0 for messages to the reading device and 1 for messages to the host. The device ID is a unique number to establish the connection with the reading device. It consists of an 8-bit gateway ID (bit 0-7) and a 7-bit reader ID (bit 8-14). The gateway ID in the delivery state corresponds to the last two hexadecimal characters of the serial number of the reader. The reader ID has the value 0x01 in the delivery state. Of course, the device ID can be changed via the corresponding parameters Gateway ID and Reader ID within the validity range. See example with Reader ID 0x01 and Gateway ID 0x00:
Upper Devic-ID (Reader-ID) R-Bit 0 0 0 0 0 0 1 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 79 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Lower Device-ID (Gateway-ID) 0 0 0 0 0 0 0 0 Direction reading device to host 0x8000 0x0000 Direction host to system (reading device) The W bit indicates whether the transmitter of the primary message wait for a reply. If the W bit contains the value 1, it means that a reply is expected. The message ID determines the format and the content of the transmitted message. It consists of a stream and a function. The stream defines the message group and the function, the exact meaning and the syntax of the message. A primary message (request) is defined as an uneven message. A secondary message is defined as an even message (reply). The end bit indicates whether a block is the last block of the message. A value of 1 means that the block is the last block. Since all messages can be transmitted in a block, the block number always has the value 1. The system bytes in the header of each message are used to distinguish primary messages. The system bytes of the reply message must correspond to the system bytes of the corresponding primary message. The system bytes are incremented for each primary message. The checksum is calculated as the numerical sum of the unsigned binary values of all bytes after the length byte and before the checksum as well as in an individual block. For more detailed information about the structure and transmission procedure, see SEMI E4, E5, E37, E99.
(SEMI Equipment Communication Standard Message Transfer SECS) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 80 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 11.2 Directory Data Elements This section defines the data elements used in the standard SECS-II messages described in the message details section. Syntax:
Name
. Format A unique name for this data item. This name is used in the message definitions A unique name for this data item. This name is used in the message definitions. The allowed element format code that can be used for this default data element. Element format codes are displayed in hexadecimal and octal, as described in chapter Data element. The notification 3 () indicates a signed integer format (30, 31, 32, 34). A description of the data element with the meaning of each value. Where used standard messages in which the data element occurs. Description ACKC3 Verification code ACKC5 Verification code ALARM STATE 0 1 0 1
... .. .. .. Format: B[1]
Sensor 0 was the Initiator error, not accepted Format: B[1]
No error error, not accepted Format: A[1]
The value of the alarm state refers to the last read. If a read or write error occurs, the alarm state is activated. A successful read or write deactivates the alarm state. When leaving the maintenance mode, the alarm state is also deactivated. 0 1
... .. No error error, not accepted ALCD Format: B[1]
Alarm-Codebyte Only the occurrence of an error is reported. Errors are usually not reset. Bit 8 = 1 Alarm activated Where used S5F1 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 81 WE GENERATE SOLUTIONS ALID Customer manual LFM 4x Reader RFID Format: B[1]
Alarm Identifier Only the occurrence of an error is reported. Errors are usually not reset. 0 1 2 3 4 No error Automatic reading failed, the reader is busy External read failed, the reader is busy External write failed, the reader is busy No transponder could be detected when the sensor was covered, or the carrier was removed too soon (sensor uncovered) Invalid command or parameter detected Unknown error Reserved parity error or checksum error detected An unexpected confirmation has been sent Locked page could not be described Reserved 5 6 7 8 9 10 11 12 Wrong transponder type 13 14 15 16 More about error codes and the corresponding corrective measures can be found in the chapter Error Codes. External read or write failed because the sensor is not covered Reserved Reserved Reserved Where used S5F1 ALID Format: A[max40]
Alarm text The length of the alarm text is between 0 and 40 characters. Depending on the version of the reader, information about the condition of the sensor or the sensors is also transmitted in the event of an error message from the reader The information should be interpreted as follows:
ALTX[0]
0: Sensor 0 1: Sensor 1 (not available) F: Not assignable ALTX[1]
0: Sensor is not used 1: Sensor is busy E: Sensor status is not available F: Sensor is not sent ALTX[3]
Initiator of an error message
: a semicolon separates the alarm text from the sensor states Where used S5F1 State of the sensor 0 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 82 WE GENERATE SOLUTIONS ATTRID Name for an attribute for a specific object type. CIDRW Attribut definitions:
Customer manual LFM 4x Reader RFID Format: A[max25]
Configuration AlarmStatus Number of heads Current CIDRW sub-state of the alarm state OperationalStatus Current CIDRW sub-state in normal operation SoftwareRevisionLevel Change (version) of the software - maximum 8 bytes CarrierIDOffset CarrierIDLength SERIALNUM HARDWARE Offset of the CID in the CID field (MID area) Length of the CID in the CID field (MID area) Series number string String of the Hardware-Release SELF_TEST_RESULT Supply the result of the last self-test MANUFACTURER ECID_00 Parameter 0 ECID_01 Parameter 1 ECID_02 Parameter 2 ECID_03 Parameter 3 ECID_04 Parameter 4 ECID_05 Parameter 5 ECID_06 Parameter 6 ECID_07 Parameter 7 ECID_08 Parameter 8 ECID_09 Parameter 9 ECID_11 Parameter 11 ECID_12 Parameter 12 ECID_20 Parameter 20 ECID_22 Parameter 22 ECID_23 Parameter 23 ECID_24 Parameter 24 ECID_25 Parameter 25 ECID_26 Parameter 26 ECID_27 Parameter 27 ECID_29 Parameter 29 ECID_30 Parameter 30 ECID_33 Parameter 33 ECID_34 Parameter 34 ECID_35 Parameter 35 ECID_36 Parameter 36 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com String of the manufacturer Gateway ID Baudrate Inter-character timeout T1 Block protocol timeout T2 Reply timeout T3 Inter-block timeout T4 Retry limit RTY TARGETID high byte TARGETID low byte Heartbeat time ReaderID HeadID Sensor Delay for presence sensor Sensor triggered action for presence sensor Triggered read frequency r/w max repeat Transponder Type Sensor activity Sensor Watchport for presence sensor Transponder load duration (read mode) r/w synchronize Automatic Antenna adjustment Sensor type for presence sensor Special features DIP switch activation LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 83 WE GENERATE SOLUTIONS ECID_37 Parameter 37 ECID_38 Parameter 38 ECID_40 Parameter 40 ECID_41 Parameter 41 ECID_42 Parameter 42 ECID_43 Parameter 43 ECID_44 Parameter 44 ECID_45 Parameter 45 ECID_75 Parameter 75 ECID_80 Parameter 80 ECID_81 Parameter 81 ECID_82 Parameter 82 ECID_83 Parameter 83 ECID_97 Parameter 97 ECID_98 Parameter 98 ECID_99 Parameter 99 Header attribute definitions:
Customer manual LFM 4x Reader RFID MID area Test after software reset Transponder load duration (write-mode) Delay time between read cycles CarrierIDOffset CarrierIDLength FixedMID MIDFormat DIP switch state (read only) Auto adjust value antenna port 1 (read only) Auto adjust value antenna port 2 (read only) Auto adjust value antenna port 3 (read only) Auto adjust value antenna port 4 (read only) Default protocol (read only) Protocol change allowed Customer Code HeadStatus HeadID Current state corresponds to OperationalStatus Headnumber 00-xx (2Ziffern) Where used S5F1 Format: A[max4]
ATTRVAL Value of the specified attribute. CIDRW-attribute definitions:
Configuration AlarmStatus ALARM STATUS OperationalStatus Number of antenna ports 04 Current CIDRW sub-state of the 0 NO 1 ALARMS Current CIDRW sub-state of IN OPERATION IDLE reader is rest mode BUSY reader is busy MANT maintenance mode SoftwareRevisionLevel SERIALNUM HARDWARE HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com Revision (version) of the software (max. 8 bytes) serial number string (max. 15 bytes) String of the hardware release (max. 10 bytes) LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 84 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID SELF_TEST_RESULT MANUFACTURER Returns the result of the last self-test. A self-test can be triggered by message S18F13 using SSCMD. String from the manufacturer HERMOS ECID_00 bis ECID_99 see data element ECV parameters 0 - 99 Head attribute definitions:
HeadStatus IDLE BUSY NOOP HeadID Current state Reader in REST mode reader is busy Not in operation corresponds to the 2-digit target ID of the first antenna port 01 or 00 Where used S18F2, S18F3 CPVAL State request value Format: A[]
OpStatus LEDStatus LedNo Timeout Operating status, maintenance or rest mode OP ... operating status MT ... maintenance status LED-status Off ... switch off the LED On ... switch on the LED Flash ... switch the LED to flashing mode with 1Hz LED-number, 1 Byte 1 first LED of the Reader Heads (if available) 2 second LED of the Reader Heads (if available) 3 red status LED of the reader 4 green status LED of the reader Timeout duration, Units seconds 00: permanently 01 bis FF: Timeout from 1 to 255 s. After the timeout, the LED goes off. Where used S18F13 The number of LEDs per antenna input depends on the design of the hardware. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 80 WE GENERATE SOLUTIONS DATA Customer manual LFM 4x Reader RFID Format: A[max200]
The data element is a vector or string of unformatted data. The DATA area depends on the MID area of the transponder and can be between page 1 and page 17. Read-write transponder DATA corresponds to 8 byte MID corresponds to 8 byte MID Read-only transponder DATA Where used S18F6, S18F7 DATALENGTH Format: U2 The DATA LENGTH corresponds to the number of bytes to be read or written. The scope depends on the length of the MID range (parameter 37). Where used S18F5, S18F7 DATASEG Format: A[2]
Used to identify the requested data. The DATASEG corresponds to the page number (PAGEID) of the transponder. 00 First page of each transponder or first page of the DATA area. Multipage transponders (pages 1 to 17):
01
... page 1
... 81
... 91 Locked page 1
... Locked page 17 11 page 17 Read-Only-Transponder Read-Write-Transponder F0 Read only one page F1 Read or write only one page Where used S18F5, S18F7 EAC Confirmation code for new reader attribute 0 ... parameter successfully set 1 ... parameter could not be set Where used S2F16 Format: B[1]
ECID Format: U1 Parameter number of the reader. The values are displayed as decimal values. Where used S2F13, S2F15 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 81 WE GENERATE SOLUTIONS ECV Customer manual LFM 4x Reader RFID Format: U1 Value of the reader parameter. The values are displayed as decimal values, see parameters. Where used S2F14, S2F15 MDLN Plant model number (Hardware version) Where used S1F2 MF Format: A[6]
Format: B[1]
Material Format Code 20: The material port number corresponds to the sensor number and the sensor status. Where used S3F5, S3F7 MHEAD Format: B[10]
The data element MHED consists of the head of the SECS message block associated with the defective message block. Where used S9F1, S9F3, S9F5, S9F9 MID Format: A Material ID, predefined area on the transponder in which the unique identifier of the cassette / box is stored. Depending on the type of transponder, the length of the MID can be changed. Multipage-Transponder:
Read-Write-Transponder:
Transponder:
The MID length can be set from 0 (no MID) to 10 (MID occupies the first 10 pages). The MID corresponds to the DATA (writable) Read-Only-
The MID corresponds to the DATA (fixed) Where used S18F10, S18F11 Please note the parameters 42-45 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 82 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID MIDAC Format: B[1]
Material ID verification code 0 1 2 Material ID confirmed; the presence sensor was the initiator Not specified Material ID confirmed - reaction to externally triggered process; the message can not be assigned to a sensor Material ID not confirmed
>2 The initiator can be taken from the data element PTN. Where used S3F14 MIDRA Material ID verification code 2 confirmation, MID will be sent later in S3F13 Where used S3F12 OFLACK Confirmation code for OFFLINE request. 0 ONLINE accepted (reader is online) Where used S1F16 Format: B[1]
Format: B[1]
ONLACK Format: B[1]
Confirmation code for ONLINE request. 0 ONLINE accepted (reader is online) Where used S1F18 PAGEDATA Format: B[9]
The data element corresponds to the transponder data. It contains the transponder page and the data content of the page. PAGEDATA [0]
Correspond to the page number. The value of the page number is displayed in the data element DATASEG. The 8 bytes (one page) of the transponder ID follow. PAGEDATA [1-8]
Where used S3F7, S3F13 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 83 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID PTN Format: B[1]
Information about the condition of up to two sensors and the initiator of the message. Initiator Bit0 .Bit 4:
The initiator sets the number of the sensor that triggered the message. 1 4 port1 to port4 Sensorstate Bit5 .Bit 7:
The current state of the sensor is described with 3 bits. 0 Sensor is not occupied 1 Sensor is occupied or detected 7 Sensor not defined Example: 0x24 means Sensor ist deteced (0x20) and the initiator was sensor at port4 (0x04) Where used S3F5, S3F7, S3F13 PM Information Format: A[2]
Information about the operating mode NE normal execution MR operating mode maintenance required Where used S18F2, S18F4, S18F8, S18F10, S18F12, S18F14 RAC Confirmation code reset 0 1 Reset could be executed Reset could not be executed Where used S18F20 RIC 1 Power-up-Reset 2 Software reset (without reset of the Ethernet component) Where used S2F19 Format: B[1]
Format: B[1]
SHEAD Format: B[10]
Head of the stored SECS message block. Only the last message is saved. This must be confirmed by the host. Where used S9F9 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 84 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID SOFTREV Format: A[max 6]
Software version Where used S1F2 SSACK Format: A[2]
Normal Operation Result information about the status of the request for the service request. NO Indicates the success of the requested operation. EE Transponder data cannot be read. MID sequence cannot be read, as valid ASCII characters were not Execution error found exclusively in the defined MID area. However, the condition of the facilities is normal. Communication error Hardware error CE Syntax error in message, message format, or value. HE Error in the head of the ID reader / writer, head of the ID reader / writer is deactivated. TE NT Transponder error, reading / writing unsuccessful (Tag Error) No transponder detected in the antenna area. (No Tag) SSCMD Where used S18F2, S18F4, S18F8, S18F10, S18F12, S18F14 Format: A[max 18]
Specifies an operation to be performed by the subsystem. Used to distinguish between the various subsystem commands displayed. ChangeState GetStatus Reset PerformDiagnostics A diagnosis is made. ADJUST HERMOSDefParams Basic setting of the readers parameters. SetLED change status query staus reset CIDRW triggers an automatic alignment of the antenna. Set one of the device LEDs. CPVALs 1 <LEDStatus>
2 <Timeout>
3 <LEDNo>
Where used S18F13 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 85 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID Status list Format: A[2]
The status list provides information about the system status. Consists of PM Information and the current values of the CIDRW attributes AlarmStatus, Operating Status and HeadStatus. Status list L,4
<PMInformation>
<AlarmStatus>
<OperatingStatus>
<HeadStatus>
TARGETID Where used S18F2, S18F4, S18F8, S18F10, S18F12, S18F14 Format: A[2]
The TargetID is defined with 2 decimal ASCII characters and corresponds to the antenna connections. The 2-digit target ID (Head-ID) is used to set the antenna port 1 to 4 for which the action is to be carried out.
(see Adressing the antenna ports). The use of the 4-digit TARGETID is currently not supported. Where used S18F1, S18F3, S18F4, S18F7, S18F9, S18F11, S18F13 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 86 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S1F1 S1F15 S1F17 S2F13 S2F15 S2F19 Read parameter Write parameter Transmit reset
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader) Are you there request Request Offline Request Online MID detected by sensor MID removed from sensor Read MID 11.3 Protocol commands The message record describes the communication data between a reading device with and a host. The following functions can be used via commands by the host in the reading device or automatically transmitted from the reading device to the host:
Stream 1: (System state) Stream 2: (System control) Stream 3: (Material state) Stream 5: (Exception handling) Stream 9: (System error) Stream 18: (System state) Read parameter Write parameter Read data Write data Read MID Write MID Subsystem command Unrecognised device ID Unrecognised stream type Unrecognised function type Invalid data Transmission timeout
(Reader Host)
(Reader Host)
(Reader Host)
(Reader Host)
(Reader Host)
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader)
(Host Reader) S18F1 S18F3 S18F5 S18F7 S18F9 S18F11 S18F13
(Reader Host)
(Reader Host)
(Reader Host) S9F1 S9F3 S9F5 S9F7 S9F9 S3F5 S3F7 S3F13
(Reader Host) Alarm message S5F1 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 87 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 11.3.1 Stream 1 (system state) S1F0: ABORT TRANSACTION (reading device <-> host) This message is used instead of an expected reply to cancel an action. The function 0 is defined in each stream and has the same meaning in each stream. S1F0 (header only, no additional elements) S1F1: ARE YOU THERE REQUEST (reading device <-> host, reply) Determines whether the reading device or the host is online. S1F1 W (header only, no additional elements) S1F2: ON-LINE DATA (host -> reading device) The host indicates that it is online. S1F2
<L[2]
<A[6] MDLN >
<A[6] SOFTREV S1F2: ON-LINE (reading device -> host) The reading device indicates that it is online. S1F2
<L[2]
<A[6] MDLN >
<A[6] SOFTREV >
S1F15: REQUEST OFF_LINE (host -> reading device, reply) The reading device contains a request to change the communication state to offline. The reading device can only be set to online again using the message S1F17 (or reset S2F19);
all other messages are cancelled by message SxF0. S1F15 W (header only, no additional elements) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 88 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S1F16: OFFLINE ACKNOWLEDGE (reading device -> host) Acknowledgement. S1F16
<B[1] OFLACK>. S1F17: REQUEST ON_LINE (host -> reading device, reply) The reading device contains a request to change the communication state to online. S1F17 W
(header only, no additional elements) S1F18: ONLINE ACKNOWLEDGE (reading device -> host) Acknowledgement S1F18
<B[1] ONLACK>
11.3.2 Stream 2 (system control) S2F0: ABORT TRANSACTION (reading device <-> host) This message is used instead of an expected reply to cancel an action. S2F0 (header only, no additional elements) S2F13: EQUIPMENT CONSTANT REQUEST (host -> reading device, reply) The host requests an attribute (parameter) from the reading device. S2F13 W
<L[1]
<U1[1] ECID>
S2F14: EQUIPMENT CONSTANT DATA (reading device -> host) The reading device transmits the requested attribute (parameter) to the host. S2F14
<L[1]
<U1[1] ECV>
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 89 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S2F15: NEW EQUIPMENT CONSTANT SENT (host -> reading device, reply) The host changes a reading device attribute (parameter). S2F15 W
<L[1]
<L[2]
<U1[1] ECID>
<U1[1] ECV>
S2F16: NEW EQUIPMENT CONSTANT ACKNOWLEDGE (reading device ->host) The reading device acknowledges the reading device parameter). S2F16
<B[1] EAC>
S2F19: RESET SENT (host -> reading device, reply) The host transmits a request to the reading device to reset the hardware and software. If a heartbeat time (parameter 9) is set, the reading device transmits a S1F1 message once the reset operation is complete. A power-up reset takes a few seconds. S2F19 W
<B[1] RIC>
S2F20: RESET ACKNOWLEDGE (reading device -> host) The reading device acknowledges the reset. This message is only displayed if a software reset (RIC=2) has been triggered. S2F20
<B[1] RAC>
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 90 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 11.3.3 Stream 3 (Material-state) S3F5: Material found (MID FOUND) (reading device-> host, reply) The reader sends the information that material has been detected on the input sensor. This message is sent only when a sensor is connected and activated.
(see par. 26 Sensor Activity and par. 27 Watchport) S3F5 W
<L[2]
<B[1] MF >
<B[1] PTN >
S3F6: Material found confirmation (MID FOUND, ACK) (host -> reading device) The host confirms the message material found. S3F6
<B[1] ACKC3 >
S3F7: Material lost (MID LOST) (reading device -> host, reply) The reader sends the information that material has been removed from the input sensor. This message is sent only when a sensor is connected and activated.
(see par. 26 Sensor Activity and par. 27 Watchport) The PAGEDATA are only indicated if the last reading was successful. S3F7 W
<L[2]
<B[1] MF >
<B[1] PTN >
<B[9] PAGEDATA >
S3F8: Material lost confirmation (MID LOST, ACK) (host -> reading device) The host confirms the message material lost. S3F8
<B[1] ACKC3 >
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 91 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S3F13: MID found (MID READ) (reading device -> host, reply) The reader sends the MID of the set up material to the host. S3F13 W
<L[2]
<B[1] PTN >
<B[9] PAGEDATA >
S3F14: Material found confirmation (MID FOUND, ACK) (host -> reading device) The host confirms the received MID data. S3F14
<B[1] MIDAC >
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 92 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 11.3.4 Stream 5 (Exception handling) S5F1: Alarm Report (reading device -> host, reply) The reader reports an error to the host. S5F1 W
<L[3]
<B[1] ALCD >
<B[1] ALID >
<A[MAX 40] ALTX > Alarmtext Alarmcodebyte Alarm-ID S5F2: Alarm Report confirmation (Host -> Lesegert) The host confirms the alarm message. S5F2
<B[1] ACKC5 >
11.3.5 Stream 9 (system error) S9F1: UNRECOGNIZED DEVICE ID (reading device -> host) The device ID in the header of the message block does not correspond to the expected device ID. S9F1
<B[10] MHEAD >
S9F3: UNRECOGNIZED STREAM TYPE (reading device -> host) The reading device does not recognise the stream type in the header of the message block. S9F3
< B[10] MHEAD >
S9F5: UNRECOGNIZED FUNCTION TYPE (reading device-> host) The reading device does not recognise the function number in the header of the message block. S9F5
< B[10] MHEAD >
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 93 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S9F7: ILLEGAL DATA (reading device -> host) The reading device does not recognise the data in the message. S9F7
< B[10] MHEAD >
S9F9: TRANSACTION TIMER TIMEOUT (reading device -> host) This message indicates a timeout of a transmission timer and the cancellation of the corresponding transaction. Only the most recently transmitted message (that must be acknowledged by the host) is saved and its acknowledgement is monitored by time. S9F9
< B[10] SHEAD >
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 94 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 11.3.6 Stream 18 (control and data transfer) S18F0: ABORT TRANSACTION (reading device -> host) This message is used instead of an expected reply to cancel an action. S18F0 (header only, no additional elements) S18F1: Read parameter (host -> reading device, reply) This message requests the current values of the parameters or states. Several attributes can be queried simultaneously by one message. S18F1 W
<L,2
<TARG ETID>
< Ln
<ATTRID1>
<ATTRIDn>
S18F2: Read parameter, confirmation (reading device -> host) This message requests the current values of the requested parameters or states. S18F2
<L,4
<TARGETID>
<SSACK>
< L,n
<ATTRVAL1>
<ATTRVALn>
< L,1
<STATUSLISTE>
If the ATTRID of the S18F1 message is not known, the corresponding element ATTRVAL receives the value <nothing>. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 95 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S18F5: Read data (host -> reading device, reply) This message is used for requesting the antenna head specified in the TARGETID for reading data (from the data area). DATASEG defines the start address of the data to be read. DATALENGTH defines the data volume of the data to be read. S18F5 W
<L,3
<TARGETID>
<DATASEG>
<DATALENGTH>
If both the DATASEG as well as the DATALENGTH are missing (elements with zero length), all pages of the data area are queried. If only the DATALENGTH is missing, all data on the specified start address is queried. If the TARGETID is not known, a communication error (CE) occurs. S18F6: Read data, confirmation (reading device -> host) This message is used to return the requested information of the antenna head specified in the TARGETID or acknowledge the result of the request. S18F6
<L,3
<TARGETID>
<SSACK>
<DATA>
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 96 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S18F7: Write Data (host -> reading device, reply) This message is used for requesting the antenna head specified in the TARGETID to write data. DATA- SEG defines the start address of the data to be written. DATALENGTH defines the data volume of the data to be written. S18F7 W
<L,4
<TARGETID>
<DATASEG>
<DATALENGTH>
<DATA>
If both the DATASEG as well as the DATALENGTH are missing (elements with zero length), all pages of the data area are overwritten. If only DATALENGTH is missing or if DATALENGTH has the value zero, all data within the specified section must be written. If the TARGETID is not known, a communication error (CE) occurs. If DATASEG is missing (elements with zero length), the DATALENGTH value determines the length of the data to be written. If the length of the data to be written is greater than the value of the DATALENGTH, a communication error (CE) occurs. S18F8: WRITE DATA ACKNOWLEDGE (WDA) (reading device ->host) This message indicates whether the process for writing data on the antenna port specified in the TARGETID was successful or failed. S18F8
<TARGETID>
<L,3
<SSACK>
< L,1
...<STATUSLISTE>
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 97 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S18F9: Read MID (host -> reading device, reply) This message is used for requesting the antenna head specified in the TARGETID for reading the MID. S18F9,W
<TARGETID>
S18F10: Read MID acknowledgement (reading devicet -> host) This message returns a requested MID from the antenna head specified in the TARGETID. S18F10
<L,4
<TARGETID>
<SSACK>
<MID>
< L,1
<STATUSLISTE>
The reading device can be in maintenance mode (MT) or operating mode (OP) to read the MID with the message S18F9. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 98 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S18F11: Write data (host -> reading device, reply) This message is used for writing the MID on the antenna head specified in the TARGETID. S18F11,W
<TARGETID>
<MID>
The reading device must be in maintenance mode to write the MID with the Message S18F11. If the reading device is not in maintenance mode, the execution is cancelled and acknowledged with SSACK = EE equipment error. S18F12: Write Data, Acknowledgment (reading device -> host) This message indicates whether the process for writing the MID on the subsystem specified in the TAR- GETID was successful or failed. S18F12
<L,4
<TARGETID>
<SSACK>
< L,1
<STATUSLISTE>
The reading device can be in maintenance mode (MT) to write the MID with the message S18F11. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 99 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S18F13: SUBSYSTEM COMMAND (host -> reading device, reply) This message is used for requesting the subsystem specified in the TARGETID for executing a specific procedure. S18F13 ,W
<L,3
<TARGETID>
<SSCMD>
<L,n 1. <CPVAL>
n. <CPVALn>
S18F14: SUBSYSTEM COMMAND, ACKNOWLEDGE (Reading device-> host) This message reports the result of the requested procedure. S18F14 ,W
<L,3
<TARGETID>
<SSACK>
< L,1
<STATUSLISTE>
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 100 WE GENERATE SOLUTIONS 11.4 Parameter Customer manual LFM 4x Reader RFID
*): Since software revision V1.5 some parameters are implemented for each antenna port (parameter array). Addressing of the parameter takes place via the reader ID of the message. In this realisation, the parameter is present once per antenna port. If no parameter arrays should be used, please ask the manufacturer
(parameter 63)!
**): Since software revision V1.5, the reader is always started with the default baud rate 19200Bd because of the protocol recognition. Please ask manufacturer HERMOS if other baud rate is required!
Nr.
(DEZ) Nr.
(HEX) Parameter name Description The gateway ID is part of the device ID. The reading unit simultaneously acts as gateway and reader (CID-
RW with integrated read head). It corresponds to the Lower Device-ID in the message header. 00 .. 255 Default: Low Byte of serial number Data transmission rate of the RS232 interface Default: 192 19200 Baud **) 1 100 1/10 s Default :
(5) 0,5 s 1 250 1/10 s Default :
(30) 3 s 1 120 1 s Default :
1 120 1 s Default :
(10) 10 s
(45) 45 s Number of retry attempts for a question or message. Default :
3 The reader sends a S1F1 message to the host at specified intervals. 0 no heartbeat 1 255 1 s (1-255s) Default :
0 no Heartbeat The reader ID is part of the device ID. The reader ID corresponds to the 7 LSB (least significant bits) of the Upper Device ID in the message header. 00 127 (0x00 0x7F) Default :
0x01 0 0x00 Gateway ID 1 2 3 4 5 6 9 0x01 Baud rate 0x02 Inter-character Timeout T1 0x03 Block protocol Timeout T2 0x04 Reply Timeout T3 0x05 Inter-block Timeout T4 0x06 Retry limit RTY 0x09 Heartbeat time 11 0x0B ReaderID HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 101 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 14 0x0E Sensor polarity for indi-
vidual presence sensor 18 0x12 Sensorstate of all heads 19 0x13 Data length autoread 20 0x14 Sensor delay time 0 Type of sensor signal to start an automatic read. The setting is applied for the addressed sensor. 0 read process when sensor is covered 1 read process when sensor is uncovered Default :
Realisation: a separate parameter for each port *) The sensor status of each head is represented by a bit. The parameter can only be queried (readonly). 1 Sensor is assigned 0 Sensor is not assigned Bsp. 0b00001010 : Sensor at Head2 and Head4 is assigned The parameter determines the number of bytes read from the tag during an automatic read 0 136 (maximale 17 pages !!) Default:
Realisation: a separate parameter for each port *) 8 Databytes 10 (1s) Delay of the sensor event before a sensor event is triggered and an automatic read operation is started. 0 255 (1/10s) Default:
Realisation: a separate parameter for each port *) Read mode for reading automatically started by exter-
nal input. 00 - read only one page 01 - read until the end character or empty character2) 02 - read all pages 10 - read only one page with previous sensor Check1) 11 - read until the end character / empty character with previous sensor Check 1) 2) 12 - read all pages with previous sensor Check1) 21 0x15 Readmode sensor triggered reading 1) If the Sensor Check (10, 11 and 12) is activated, the assignment of the potential-free input is checked before initiating a read / write process. When used, the read / write process is started, other-
wise the error message NOTAG is sent. 2) E or F in ID bits 0 ... 3 of the read ID 22 0x16 Page number for readmode 00 Default: 00 (read only one page) Realisation: a separate parameter for each port *) The page to read for readmode 00:
0: Read all transponders 1: Page 1 Read multipage transponders
... 17: Page 17 Read multipage transponders 240: read read-only transponder 241: read read-write transponder Default:
Realisation: a separate parameter for each port *) 0 (read all transponders) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 102 WE GENERATE SOLUTIONS 23 0x17 Triggered read frequency Customer manual LFM 4x Reader RFID For a read / write error, the triggered reading frequen-
cy sets the time between two read / write attempts for a transponder;
Read frequency in case of a triggered read (no polling) 02 10 (1/10s) Default: 5 (0,5s) Realisation: a separate parameter for each port *) 24 0x18 r/w max repeat 25 0x19 Transponder Type 26 0x1A Sensor Activity 27 0x1B Watchport for individual Presence Sensor 29 0x1D Transponder load duration
(read mode) 30 0x1E r/w synchronize 5 Maximum number of read and write retries 0 255 Default:
Realisation: a separate parameter for each port *) The parameter defines the validity of the read data of the transponder. 0 read / write type TIRIS Each transponder page consists of 8 data bytes and 2 bytes CRC checksum. The validity of the data bytes is verified by a checksum 1 A transponder page is interpreted as 10 data bytes without checksum. Default:
0 The sensor activity of each head is represented by a bit. For each sensor exactly one bit is provided. 0 Sensor not activated 1 Sensor activated Standard:
0x0F Enables a message to the host if a sensor has been used or if the occupancy has been removed. A sensor is required on use this feature. 0 message no action 1 message Sensor assignment has been removed 3 2 message Sensor assignment has been detected 3 message occupancy detected and removed. Default:
Realisation: a separate parameter for each port *) Charging time of a transponder during the reading process. The default setting should not be changed. Default:
Realisation: a separate parameter for each port *) Activates / deactivates the synchronization of the reader. When synchronization is enabled, the reader detects interference or other active readers and synchronizes the read cycle . 0 synchronization deactivated 1 synchronization activated Default:
1 activated 50 (50ms) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 103 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 33 0x21 Automatic antenna tuning 34 0x22 Sensor polarity of all presence sensors 35 0x23 Spezial Features 3 0 (reading starts on all sensors when
... execute read operation after reset, when sensor is The parameter controls the allowed triggers of an automatic adjustment of the antenna . 0 autom. Customization is not activated 1 ... autom. Adaptation via DIP4 2 ... autom. Adaptation by external command 3 ... autom. Adaptation via DIP4 or external command Default:
Type of sensor signal to start an automatic read. One bit is provided for each sensor (Bit0 Sensor 1, ..., Bit3 Sensor 4) with the following meaning 0 read when sensor is covered 1 read when sensor is uncovered Value range Parameter: 0x00 bis 0x0F Default:
sensor is covered) Bit 0: After a hardware reset, the reader will auto-read if the presence sensor is covered. 0 covered 1 sensor is covered (standard) Bit 1: Trigger sensor-triggered automatic read opera-
tion 0 trigger 1 Bit 2: 0: non volatile memory is used for saving the reader ID at reset process Bit 2: 1: non volatile memory ist not used Bit 3: without function Bit 4: set external head LED1 at sensor triggered read Bit 5: page transfer when reading the first page of a multipage transponder 0 ... without page transfer 1 ... with page transfer Bit 6: external head LED1 will be influenced at ASC-
W1 mode Bit 7: external head LED2 will be influenced at ASC-
W1 mode Default:
... Do not execute a read after reset, when the
... No automatic reading with detected sensor
... reading after detected sensor 0x01 (0000 0001) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 104 WE GENERATE SOLUTIONS 36 0x24 DIP switch activation Customer manual LFM 4x Reader RFID Bit 0 to bit 4 defines the behavior of the four externally accessible DIP switches. Bit0: DIP 4 active Bit1: DIP 3 active Bit2: DIP 2 active Bit3:
DIP 1 active Bit4: Value (1): If no test mode is activated (DIP3 =
OFF), the set antenna port (via DIP1 and DIP2) is tuned automatically by changing the DIP 4 from OFF to ON. If tuning is successful, the adjustment for the port is saved and the Status LED is switched on. Default:
0x1F 37 0x25 MID Area 38 0x26 Test after software reset The parameter defines the range of the MID. The parameter defines the maximum number of pages of a transponder reserved for the MID. One page usually has 8 bytes of data. The default value is customer specific 010 pages Default:
This parameter activates / deactivates the initial test after a software reset . 0 No initial test after software reset 1 initial test after software reset Default:
0,1 or 2 pages 0 40 0x28 Transponder load duration
(write mode) Charging time of a transponder during the writing process. The default setting should not be changed Default:
50 (50ms) 41 0x29 Delay time between read cycles 42 0x2A CarrierIDOffset 43 0x3B CarrierIDLength 10 (10ms) Delay time between two read cycles. A reduction of the delay increases the reading speed. 1 .. 250 (1 ms) Default:
Sets the offset of the CID (= MID) within the MID area. The valid value range depends on the value of the MIDArea (maximum MID range) and the CarrierID-
Length. Default:
Sets the length of the CID (= MID) within the MID area. The valid value range depends on the value of the MIDArea (maximum MID range) and the Carrie-
rIDLength. The default value is customer specific!
Default:
0 or 16 0 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 105 WE GENERATE SOLUTIONS 44 0x2C FixedMID 45 0x2D MIDFormat 59 0x3B Hardware Error
(read only) 60 0x3C Threshold Noise Level 61 0x3D Noise Level
(read only) 62 0x3E Noise Detected
(read only) Customer manual LFM 4x Reader RFID Defines the read and write behavior of the CID length specified in SEMI E99-03. 0 ... Dynamic CID length The length of the MID is variable. Valid Lengths are from 1 - CID Length Bytes. 1 ... Fixed CID length The length of the MID is at CID Length established. A departure from this length leads to an error message. The default value is customer specific!
Default:
0 or 1 Defines the physical format of the MID data in the transponder. 0 E99 standard format left justified. Default:
0 The read-only parameter provides the information as to whether a tuning or antenna error was detected during reading. If there is an error, this is also indicated by the fast flashing red status LED. 0 no error 1 tuning error 2 antenna error 3 tuning and antenna error The parameter sets the threshold for the noise level, which is used as a measure of whether an interference field is present in the environment of the antenna. 0 255 Default:
20 The read-only parameter provides the information as to which noise level in the environment of the antenna could currently be measured. The value is a measure of ambient noise and interference in the environment of the antenna. Values above an adjustable threshold
(parameter 60) are interpreted as a interference
(noise). The read-only parameter provides the information as to whether the ambient noise level measured in the environment of the antennas is interpreted as interference (threshold Noise Level exceeded). See also parameters 60 and 61. 70 0x46 Software Version String
(read only) The read-only parameter returns the complete identifier of the current firmware. 71 0x47 Serial number string
(read only) The read-only parameter provides the complete serial number string. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 106 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 72 0x48 Hardwarerevision String
(read only) The read-only parameter provides the complete identifier for the hardware version. 75 0x4B DIP switch status (read only) 76 0x4C Saved fatal errors or events
(read only) 80 0x50 Antenna tuning of the antenna 1 The parameter is used to query the position of all DIP switches. Bit0: DIP 4 (0=off, 1=on) Bit1: DIP 3 (0=off, 1=on) Bit2:
DIP 2 (0=off, 1=on) Bit3: DIP 1 (0=off, 1=on) The result is independent of parameter 36 (0x24). The read-only parameter retrieves all errors and events stored in a ring memory. Since only about 25 characters are read out of the memory per call, it may need to be retrieved several times until it is completely emptied. Fatal errors and the creation of default paramters will be saved. By automatically adjusting the antenna, the influence of ambient conditions can be minimized 00 ... 15 value of antenna adjustment 81 0x51 Antenna tuning of the antenna 2 See parameter 80 82 0x52 Antenna tuning of the antenna 3 See parameter 80 83 0x53 Antenna tuning of the antenna 4 See parameter 80 84 0x54 Antenna tuning of the addressed antenna By automatically adjusting the antenna, the influence of ambient conditions can be minimized 00 ... 15 value of antenna adjustment Default: 08 Realisation: a separate parameter for each port *) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 107 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID 96 0x60 Set default parameters 97 0x61 Default protocol 98 0x62 Protocol change allow 99 0x63 Customer Code Via this parameter default parameters of the reader can be established. Factor setting parameters remain unaffected!
0... reset all parameters 1... reset all parameters except network settings The query of the parameter returns the fine version of the software version. This parameter provides information about the currently set protocol. Automatic protocol selection distinguishes between "ASCII" and "ASCII"
1 "SECS" protocol. Setting the parameter causes the reader to be restarted if the protocol is changed. SECS/HSMS 2 ASCII Default: 1 This parameter can be used to allow a detected protocol change. This will then set the new default protocol and restart the device. If the protocol change is suppressed, no automatic change takes place. 0 protocol change not allowed 1 ... protocol change allowed Default: 1 Special customer parameter settings that differ from the basic settings. Several parameter values are set by a customer code. The following parameters are defined:
0 device version according to SEMI E99-0303 Par. 37 = 2 Par. 42 = 0 Par. 43 = 16 Par. 44 = 1 Par. 45 = 0 3 device version before SEMI E99-0303 Par. 37 = 1 Par. 42 = 0 Par. 43 = 8 Par. 44 = 0 Par. 45 = 0 4 device version without MID Par. 37 = 0 Par. 42 = 0 Par. 43 = 0 Par. 44 = 1 Par. 45 = 0 Default: 0 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 108 WE GENERATE SOLUTIONS 11.5 Examples of a SECS / HSMS message Start routine of the HSMS protocol:
Customer manual LFM 4x Reader RFID S1F1 Query Software version S2F13 Query parameter 3 S2F15 Set parameter 3 to value 5 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 109 WE GENERATE SOLUTIONS Automatic reading by sensor event:
S3F5 - Material found S3F13 - MID read Customer manual LFM 4x Reader RFID S3F7 - Material lost S18F5 - Read data Antenna port: 1 Page:
Data length:
3 8 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 110 Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS S18F7 - Write data Antenna port: 1 Page:
Data length:
3 8 Data:
ABCDEFGH S18F9 Read MID HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 111 WE GENERATE SOLUTIONS Customer manual LFM 4x Reader RFID S18F11 - Describe MID With the message S18F11 the MID area can be described. The MID can only be written in maintenance mode. Use the S18F13 message to put the reading device into the maintenance state. S18F13 Subsystem Command Change to Maintenance Mode The reading device must first be set to maintenance mode to write tot he MID area. SSCMD = ChangeState CPVAL = MT The CPVAL OP can be used to switch back to the normal
(Maintenance) operating mode. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 112 WE GENERATE SOLUTIONS 11.6 Error codes Customer manual LFM 4x Reader RFID SSACK Name Description Cause Corrective action NO Normal operation Indicates the success of the requested operation no EE Execute Error Transponderdaten und Lese-ID-
Sequenz knnen nicht gelesen werden CE Communica tion Error Syntax error with message or message format or wrong value Reader processes previous read or write request Please wait until previous query is finished Transponder has no or too few valid ASCII characters in the MID area Program transponder with valid ASCII characters in the MID area Parameters for MID range do not match the transpon-
der data Adjust reader parameter for MID area according to transponder data area for MID Wrong reader mode
(MANT / OP) for functional operation List format, list set or data type is wrong Data sent with a command is incorrect Switch to proper mode (MANT to write MID) Check SECS message syntax Check command syntax and data Send parameter is not im-
plemented or out of range Check parameter syntax and value HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 110 WE GENERATE SOLUTIONS 12. Service and Troubleshooting 12.1 General information Customer manual LFM 4x Reader RFID Follow the basic safety instructions in the chapter Safety instructions. The maintenance of the reading device and its components may only be performed by the manufacturer. Observe the instructions in this section when errors occur. Do not perform any further troubleshooting measures in addition to the described measures. In case of doubt concerning errors and handling them, contact the manufacturer. 12.2 Troubleshooting personnel Troubleshooting must only be performed by specially trained personnel. In case of doubts concerning the necessary qualifications, contact the manufacturer. The handling of device errors by untrained personnel as well as the incorrect handling of the device can result in personal injuries as well as damages to the reading device and/or connected devices. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 111 WE GENERATE SOLUTIONS 12.3 Safety instructions Customer manual LFM 4x Reader RFID All components of the antenna oscillating circuit carry high voltage. Only use spare parts specified by the manufacturer. Unauthorised substitution of parts can result in fire, electric shock or other hazards. Electrostatic charges damage electronic components within the device. ESD protective measures must be applied prior to opening the unit. Carefully remove the housing covers to prevent damage. Do not operate the device when the housing is open. Never short circuit the fuse! This may result in fire or damages on the device. Only use fuses specified by the manufacturer. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 112 WE GENERATE SOLUTIONS 12.4 Error indications on the device Power-LED is off Customer manual LFM 4x Reader RFID Check the power supply and the connecting cables!
Remove the power adapter. Open the case and check the fuse. Replace the fuse with a fuse specified by the manufacturer!
If the above measures do not resolve the problem, contact the manufacturer. 12.5 No communication with the reading device Check the interface connection cable for damage and correct connection!
Check the power LED is lit, and make sure that the status indicator does not indicate an error. Try to read in the reader with the HERMOS Device-Discoverer and check the device settings. If the above measures do not correct the error, please contact the manufacturer. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 113 WE GENERATE SOLUTIONS 12.6 Software releases Customer manual LFM 4x Reader RFID Release-date Version Description 12.05.2017 LFM4I1.1 (ASCII) LFMS11 (SECS/HSMS) Initial release 24.01.2018 09.07.2018 LFM4I1.3 (ASCII) LFMS13 (SECS/HSMS) LFM4I1.4 (ASCII) LFMS14 (SECS/HSMS) 17.01.2019 LFM4I1.5 (ASCII) LFMS15 (SECS/HSMS) ASC-W1 Mode, I/Os Erweiterung um Kunden-
modus 4 mit ReaderID 0 bis 3. Another Factoryparameterset 5, which makes special settings for the 24 volt I /
O module (6 sensors and 8 outputs). ReaderID from value 0.
- Partial parameterization per antenna port
- Readertest over UDP Protocol
- Storing of FatalErrors in the EEPROM and their retrieval HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 114 WE GENERATE SOLUTIONS 12.7 Customer service HERMOS AG Customer manual LFM 4x Reader RFID Track & Trace RFID Division Gartenstrae 19 D-95490 Mistelgau Germany Phone Fax E-Mail URL:
+49 (0) 9279 991 - 0
+49 (0) 9279 991 - 100 rfid@hermos.com http://www.hermos.com/de/produkte/rfid/
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 115 WE GENERATE SOLUTIONS 13. Disassembly and storage 13.1 Disassembly Customer manual LFM 4x Reader RFID Remove the power supply Remove all cables Loosen and remove the mounting screws Remove the reading device from the installation area 13.2 Storage Store the reading device and its components in a clean and dry environment. Make sure that the power supply has been removed. Observe the required storage conditions specified in the technical data. 14. Transport and disposal 14.1 Transport Use a solid cardboard box for the transport. Use enough cushioning material to protect the device on all sides. 14.2 Disposal The device and its components are made of various materials. Disconnect the electronic components from the housing and dispose of them separately. Do not dispose of the unit in normal household waste. Dispose of the materials separately and according to the legal regulations of your country. Housing and attachments as plastic waste Electronic components, antennas and cables as electronic waste HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.4 back to the table of contents www.hermos.com 116
1 | LTC request | Cover Letter(s) | 31.71 KiB | January 13 2020 |
Long/Short-term Confidentiality Request 2AP5OLFM-4X Date: 25 November 2019 PHOENIX TESTLAB GmbH Product Certification Knigswinkel 10 D 32825 Blomberg FCC ID:
To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below:
Schematics Block Diagram Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure for an initial period of days External Photos Internal Photos The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Tobias Zollner Head of Product Compliance Management Parts List Tune-Up Info Test Setup Photos Users Manual until:
not applicable
1 | Power of Attorney Letter | Cover Letter(s) | 110.67 KiB | January 13 2020 |
Ihr Zeichen:
Ihre Nachricht:
Unser Zeichen:
LD Mistelgau, 25.11.2019 Seite 1 von 1 HERMOS AG, Gartenstrae 19, 95490 Mistelgau PHOENIX TESTLAB GmbH Product Certification Department Knigswinkel 10 D 32825 Blomberg To Whom It May Concern:
Please be advised that we (Hermos AG, Gartenstr. 19, 95490 Mistelgau) authorizes the following persons from EMV Testhaus GmbH:
Mr. Tobias Zollner Mr. Konrad Gral Mr. Christian Kiermeier to handle the application of Type Approval Services for the following countries:
USA Unless future correspondence from us, please extend your full cooperation to EMV Testhaus GmbH regarding matters to 6 months after the signatory date of this authorization. Contact person Position in the company Date of signatory Dngfelder Lothar Expert Hardware Development 2019-11-25 ___________________________ Signatory
(Signature of the applicant) Vorstand: Harald Khler, Jrg Herrmannsdrfer, Uwe Herrmannsdrfer, Vorsitzender des Aufsichtsrates: Peter Heun, Rechtsanwalt AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen: HypoVereinsbank AG Bayreuth, Konto 329 829 383, BLZ 773 200 72 IBAN: DE63 7732 0072 0329 8293 83, SWIFT: HypoVereinsbank AG HYVEDEMM412 Commerzbank AG Bayreuth, Konto 1 311 166, BLZ 773 400 76 IBAN: DE16 7734 0076 0131 1166 00, BIC: COBADEFF773 VR-Bank Bayreuth, Konto 9 603 743, BLZ 773 900 00 HERMOS AG Gartenstrae 19 D-95490 Mistelgau Telefon: +49 (9279) 991-0 Telefax: +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-01-13 | 0.1342 ~ 0.1342 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-01-13
|
||||
1 | Applicant's complete, legal business name |
HERMOS AG
|
||||
1 | FCC Registration Number (FRN) |
0027610807
|
||||
1 | Physical Address |
Gartenstrasse 19
|
||||
1 |
Mistelgau, N/A
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
b******@phoenix-testlab.de
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AP5O
|
||||
1 | Equipment Product Code |
LFM-4X
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L******** D********
|
||||
1 | Telephone Number |
00499******** Extension:
|
||||
1 | Fax Number |
00499********
|
||||
1 |
l******@hermos.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | LFM Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | This device must be professionally installed. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
EMV TESTHAUS GmbH
|
||||
1 | Name |
R****** K****
|
||||
1 | Telephone Number |
49-94********
|
||||
1 | Fax Number |
49-94********
|
||||
1 |
r******@emv-testhaus.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.13420000 | 0.13420000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC