submitted | available | document details (if available) | source link |
---|---|---|---|
IAP105_IG.fm dmontgomery Acrobat Distiller 9.0.0 (Windows) |
various | Manual | Users Manual | 813.89 KiB |
IAP-105 Wireless Access Point Installation Guide About the Aruba IAP-105 Access Point The Aruba IAP-105 wireless access point supports the IEEE 802.11n standard for high-performance WLAN. This access point uses MIMO (Multiple-in, Multiple-
out) technology and other high-throughput mode techniques to deliver high-
performance, 802.11n 2.4 GHz and 5 GHz functionality while simultaneously supporting existing 802.11a/b/g wireless services. The Aruba IAP-105 access point provides the following capabilities:
Wireless transceiver Protocol-independent networking functionality IEEE 802.11a/b/g/n operation as a wireless access point IEEE 802.11a/b/g/n operation as a wireless air monitor Compatibility with IEEE 802.3af PoE Package Contents IAP-105 access point Installation guide (this document) Aruba Instant Quick Start Guide Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed. Figure 1 IAP-105 IAP-105 Hardware Overview Figure 2 IAP-105 Front 105 5 0 0 _ 5 0 1 P A 1 0 0 _ 5 0 1 P A PWR ENET 11A/N 11B/G/N LEDs The IAP-105 is equipped with four LEDs that indicate the status of the various components of the IAP. PWR: Indicates whether or not the IAP-105 is powered-on ENET: Indicates the status of the IAP-105s Ethernet port 11A/N: Indicates the status of the 802.11a/n radio 11B/G/N: Indicates the status of the 802.11b/g/n radio For information about the IAP-105s LED behavior, see Table 1 on page 2. Figure 3 IAP-105 Rear Power Connector ENET A 5 2 1
. V 2 1 C O N S O L E T E N E CONSOLE 2 0 0 _ 5 0 1 P A Reset Button Console Port Use the console port to connect to a terminal for direct local management. Ethernet Port IAP-105 is equipped with a single 10/100/1000Base-T (RJ-45) auto-sensing, MDI/
MDX wired-network connectivity port. This port supports IEEE 802.3af Power over Ethernet (PoE) compliance, accepting 48VDC as a standard defined Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE midspan injector, or network infrastructure that supports PoE. DC Power Socket If PoE is not available, an optional Aruba IAP AC-DC adapter kit (sold separately) can be used to power the IAP-105. Reset Button The reset button can be used to return the IAP to factory default settings. If you have converted your IAP to a campus AP, pressing the reset button converts it back to an IAP. To reset the IAP:
1. Power off the IAP. 2. Press and hold the reset button using a small, narrow object, such as a paperclip. 3. Power-on the IAP without releasing the reset button. The power LED will flash within 5 seconds. 4. Release the reset button. The power LED will flash again within 15 seconds indicating that the reset is completed. The IAP will now continue to boot with the factory default settings. Before You Begin
!
!
FCC Statement: Improper termination of access points installed in the United States (non-US Regulatory Domain model/s) will be in violation of the FCC grant of equipment authorization. Any such willful or intentional violation may result in a requirement by the FCC for immediate termination of operation and may be subject to forfeiture (47 CFR 1.80). EU Statement:
Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands. Please refer to the Aruba Instant User Guide for details on restrictions. Produit rseau local radio basse puissance operant dans la bande frquence 2.4 GHz et 5 GHz. Merci de vous referrer au Aruba Instant User Guide pour les details des restrictions. Low Power FunkLAN Produkt, das im 2.4 GHz und im 5 GHz Band arbeitet. Weitere Informationen bezlglich Einschrnkungen finden Sie im Aruba Instant User Guide. Apparati Radio LAN a bassa Potenza, operanti a 2.4 GHz e 5 GHz. Fare riferimento alla Aruba Instant User Guide per avere informazioni detagliate sulle restrizioni. IAP Pre-Installation Checklist Before installing your IAP-105 access point, be sure that you have the following:
CAT5 UTP cable of required length One of the following power sources:
IEEE 802.3af-compliant Power over Ethernet (PoE) source The POE source can be any power source equipment (PSE) Aruba IAP AC-DC adapter kit (sold separately) Summary of the Setup Process Successful setup of an IAP-105 access point consists of five tasks, which must be performed in this order:
1. 2. 3. Verify post-installation connectivity. Identify the specific installation location for each IAP. Install each IAP. 4. Configure each IAP. Aruba Networks, Inc., in compliance with governmental requirements, has designed the IAP-105 access points so that only authorized network administrators can change the settings. For more information about IAP configuration, refer to the Aruba Instant Quick Start Guide and Aruba Instant User Guide.
!
Access points are radio transmission devices and as such are subject to governmental regulation. Network administrators responsible for the configuration and operation of access points must comply with local broadcast regulations. Specifically, access points must use channel assignments appropriate to the location in which the access point will be used. Identifying Specific Installation Locations
!
RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems. You can mount the IAP-105 access point on a wall or on the ceiling. Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted for in VisualRF. Identifying Known RF Absorbers/Reflectors/Interference Sources Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation phase is critical. Make sure that these sources are taken into consideration when you attach an IAP to its fixed location. RF absorbers include:
Cement/concreteOld concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration within the concrete, blocking RF signals. Natural ItemsFish tanks, water fountains, ponds, and trees Brick RF reflectors include:
Metal ObjectsMetal pans between floors, rebar, fire doors, air conditioning/
heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets Do not place an IAP between two air conditioning/heating ducts. Make sure that APs are placed below ducts to avoid RF disturbances. RF interference sources include:
Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones) Cordless headset such as those used in call centers or lunch rooms Installing the IAP Service to all Aruba Networks products should be performed by trained service personnel only. Using the Integrated Wall-Mounting Slots The keyhole-shaped slots on the back of the IAP can be used to attach the device upright to an indoor wall or shelf. When you choose the mounting location, allow additional space at the right of the unit for cables. 1. Since the ports are on the back of the device, make sure that you mount the IAP in such a way that there is a clear path to the Ethernet port, such as a pre-
drilled hole in the mounting surface. 2. At the mounting location, install two screws on the wall or shelf, 1 7/8 inches
(4.7 cm) apart. If you are attaching the device to drywall, Aruba recommends using appropriate wall anchors (not included). 3. Align the mounting slots on the rear of the IAP over the screws and slide the unit into place (see Figure 4). Figure 4 Installing the IAP-105 Access Point on a Wall 3 0 0 _ 5 0 1 P A Using the Integrated Ceiling Tile Rail Slots The snap-in tile rail slots on the rear of the IAP can be used to securely attach the device directly to a 15/16" wide, standard ceiling tile rail.
!
Make sure the IAP fits securely on the ceiling tile rail when hanging the device from the ceiling; poor installation could cause it to fall onto people or equipment. 1. Pull the necessary cables through a prepared hole in the ceiling tile near 2. where the IAP will be placed. If necessary, connect the console cable to the console port on the back of the IAP. Hold the IAP next to the ceiling tile rail with the ceiling tile rail mounting slots at approximately a 30-degree angle to the ceiling tile rail (see Figure 5). Make sure that any cable slack is above the ceiling tile. Figure 5 Orienting the Ceiling Tile Rail Mounting Slots 4 0 0 _ 5 0 1 P A 3. Pushing toward the ceiling tile, rotate the IAP clockwise until the device clicks into place on the ceiling tile rail. Connecting Required Cables Install cables in accordance with all applicable local and national regulations and practices. Ethernet Ports The RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/
MDX connections. Use these ports to connect the IAP to a twisted pair Ethernet LAN segment. Use a 4- or 8-conductor, Category 5 UTP cable up to 100 m (325 feet) long. The 10/100/1000 Mbps Ethernet port is on the back of the IAP. The port has an RJ-
45 female connector with the pin-outs shown in Figure 6. Table 1 IAP-105 Series LED Meanings Figure 6 Gigabit Ethernet Port Pin-Out 1000Base-T Gigabit Ethernet Port RJ-45 Female Pin-Out 1 2 3 4 5 6 7 8 Signal Name BI_DA+
BI_DA-
BI_DB+
BI_DC+
BI_DC-
BI_DB-
BI_DD+
BI_DD-
Function Bi-directional pair +A Bi-directional pair -A Bi-directional pair +B Bi-directional pair +C Bi-directional pair -C Bi-directional pair -B Bi-directional pair +D Bi-directional pair -D Serial Console Port The serial console port (Console) allows you to connect the IAP to a serial terminal or a laptop for direct local management. This port is an RJ-45 female connector with the pinouts described in Figure 7. Connect this port in one of the following ways:
Connect it directly to a terminal or terminal server using an Ethernet cable. Use a modular adapter to convert the RJ-45 (female) connector on the IAP to a DB-9 (male) connector, and connect the adapter to a laptop using an RS-232 cable. See Figure 8 for connector details of the adapter. Figure 7 Serial Port Pin-Out Serial Console Port RJ-45 Female Pin-Out 1 2 3 4 5 6 7 8 Direction Input Output TxD GND GND RxD LED 11B/G/N Color/State Meaning Off Amber Green Green flashing 2.4 GHz radio disabled 2.4 GHz radio enabled in WLAN mode 2.4 GHz radio enabled in 11n mode 2.4 GHz Air Monitor or RF Protect mode Product Specifications Electrical Ethernet:
1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 Interfaces MDI/MDX IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T). IEEE 802.3ab
(1000Base-T) Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA (see Figure 6 for pin configuration) Power: 12 VDC power interface, supports powering through an AC-to-DC power adapter If a power adapter other than the one provided by Aruba Networks is used in the US or Canada, it should be cULus (NRTL) Listed, with an output rated 12 VDC, minimum 1.25A, marked LPS or Class 2, and suitable for plugging into a standard power receptacle in the US and Canada. Figure 8 RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion For additional specifications on this product, please refer to the data sheet. The data sheet can be found at www.arubanetworks.com. RJ-45 Female Pin-Out TxD GND RxD 1 2 3 4 5 6 7 8 Direction Input Output Internal Connections RJ-45 3 4 5 6 TxD GND RxD DB-9 2 5 3 DB-9 Male Pin-Out Ground RxD TxD 9 8 7 6 5 4 3 2 1 Direction Input Output Power Connection The IAP-105 has a single 12V DC power jack socket to support powering through an AC-to-DC power adapter. If both POE and DC power are available, the IAP uses POE even when there is not enough POE voltage available to power the IAP. Verifying Post-Installation Connectivity The integrated LEDs on the IAP can be used to verify that the IAP is receiving power and initializing successfully (see Table 1). Refer to the Aruba Instant Quick Start Guide for further details on verifying post-installation network connectivity. Table 1 IAP-105 Series LED Meanings Proper Disposal of Aruba Equipment For the most current information about Global Environmental Compliance and Aruba products, see our website at www.arubanetworks.com. Waste of Electrical and Electronic Equipment Aruba products at end of life are subject to separate collection and treatment in the EU Member States, Norway, and Switzerland and therefore are marked with the symbol shown at the left (crossed-out wheelie bin). The treatment applied at end of life of these products in these countries shall comply with the applicable national laws of countries implementing Directive 2002/96EC on Waste of Electrical and Electronic Equipment (WEEE). European Union RoHS Aruba products also comply with the EU Restriction of Hazardous Substances Directive 2002/95/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in the manufacture of electrical and electronic equipment. Specifically, restricted materials under the RoHS Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Aruba products are subject to the exemptions listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will be marked with the RoHS label shown at the left indicating conformance to this Directive. Safety and Regulatory Compliance Aruba Networks provides a multi-language document that contains country-
specific restrictions and additional safety and regulatory information for all Aruba access points. This document can be viewed or downloaded from the following location: www.arubanetworks.com/safety_addendum. The device will be electronically labeled and the FCC ID will be displayed via the controller Web UI under the About menu.
!
RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems. EMC Compliance and Warning Statement IEC 60601-1-2: 2007 EN 60601-1-2: 2007 This equipment has been tested and found to comply with the limits of the standard for medical devices, IEC 60601-1-2:2007. The unit also complies with the requirements of EN 60601-1-2:2007, providing the presumption of compliance to the European Unions Medical Device Directive 2007/47/EC. The limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the manufacturers instructions may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference with other devices, which may be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
Reorient or relocate the device receiving the interference. Increase the separation between the equipment. Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected. Consult the manufacturer or field service technician for help. The Model IAP-105 does not have an Applied Part as defined in IEC 60601-1. The protection against electric shock is Class ll. Device is not protected against ingress of liquids and has a protection class of IPX0 as defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in the presence of flammable mixtures. The unit is considered Continuous Operation equipment as defined by IEC 60601-1. Power Consumption 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for external AC supplied power (adapter sold separately); Maximum power consumption 12.5W. Mechanical Dimensions: 132mm x 135mm x 45mm; 300g. Environmental: Operating Temp: 0 C to +50 C (+32 F to +122 F); Humidity: 5 to 95% non-condensing. Storage Temp: -40 CS to +70 C (-40F to +158F). LED PWR ENET
(10/100/1000 Mbps) 11A/N Color/State Meaning China RoHS 10 Aruba products also comply with China environmental declaration requirements and are labeled with the EFUP 10 label shown at the left. Off Green flashing Red steady No power to IAP System initializing System failed to initialize, contact TAC Green steady Power on, device ready Off Green on Amber on No link 1000 Mbps link 10/100 Mbps link Green flashing Ethernet link activity Off Amber Green Green flashing 5 GHz radio is disabled 5 GHz radio enabled in WLAN mode 5 GHz radio enabled in 11n mode 5 GHz Air Monitor or RF Protect mode IAP-105 Wireless Access Point Installation Guide Contacting Aruba Networks Table 1 Contact Center Online Main Site Support Site Wireless Security Incident Response Team (WSIRT) http://www.arubanetworks.com https://support.arubanetworks.com http://www.arubanetworks.com/support/wsirt.php EMEA Support Email emea.support@arubanetworks.com WSIRT Email Please email details of any security problem found in an Aruba product. wsirt@arubanetworks.com Table 2 Service & Support Contact Center Telephone Aruba Corporate FAX
+1 (408) 227-4500
+1 (408) 227-4550 Support United States Universal Free Phone Service Number (UIFN): Australia, Canada, China, France, Germany, Hong Kong, Ireland, Israel, Japan, Korea, Singapore, South Africa, Taiwan, and the UK All Other Countries 800-WI-FI-LAN (800-943-4526)
+800-4WIFI-LAN (+800-49434-526)
+1 (408) 754-1200 Copyright 2011 Aruba Networks, Inc. AirWave, Aruba Networks, Aruba Mobility Management System, Bluescanner, For Wireless That Works, Mobile Edge Architecture, People Move. Networks Must Follow., RFProtect, The All Wireless Workplace Is Now Open For Business, and The Mobile Edge Company are trademarks of Aruba Networks, Inc. All rights reserved. All other trademarks are the property of their respective owners. Open Source Code Certain Aruba products include Open Source software code developed by third parties, including software code subject to the GNU General Public License ("GPL"), GNU Lesser General Public License ("LGPL"), or other Open Source Licenses. The Open Source code used can be found at this site:
http://www.arubanetworks.com/open_source Legal Notice The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate other vendors' VPN client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of those vendors. Warranty This hardware product is protected by the Aruba Limited Lifetime warranty. Altering this device (such as painting it) voids the warranty. www.arubanetworks.com 1344 Crossman Avenue Sunnyvale, California 94089 Phone: 408.227.4500 Fax 408.227.4550 IAP-105 Wireless Access Point | Installation Guide Part Number 0510860-03 | May 2011
This product uses the FCC Data API but is not endorsed or certified by the FCC