submitted | available | document details (if available) | source link |
---|---|---|---|
August 26 2019 | August 26 2019 | Revision History: Brian Breault Microsoft® Office Word 2007 |
various | Test Report | Test Report | 2.79 MiB | August 26 2019 |
COMPLIANCE WORLDWIDE INC. TEST REPORT 275-19R1 In Accordance with the Requirements of Federal Communications Commission 47 CFR Part 15.250, Subpart C Wideband Systems within the band 5925 to 7250 MHz ISED RSS-220, Issue 1 (March 2009) + Amendment 1 (July 2018) Devices Using Ultra-Wideband (UWB) Technology Issued to iRobot Corporation 8 Crosby Drive Bedford, MA 01730 For the TerraTM t7 Robot Mower RLA-Y1 FCC ID: UFERLA-Y1 Report Issued on August 2, 2019 Revision R1 Issued on August 7, 2019 Tested By This test report shall not be reproduced, except in full, without written permission from Compliance Worldwide, Inc. Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 Issue Date: 8/7/2019 Table of Contents 1. Scope .................................................................................................................................................. 3 2. Product Details ................................................................................................................................... 3 2.1. Manufacturer ............................................................................................................................. 3 2.2. Model Number ........................................................................................................................... 3 2.3. Serial Number ........................................................................................................................... 3 2.4. Description ................................................................................................................................ 3 2.5. Power Source ............................................................................................................................ 3 2.6. Hardware Revision .................................................................................................................... 3 2.7. Software Revision ..................................................................................................................... 3 2.8. Modulation Type ........................................................................................................................ 3 2.9. Operating Frequency ................................................................................................................ 3 2.10. EMC Modifications .................................................................................................................. 3 3. Product Configuration ......................................................................................................................... 3 3.1. Operational Characteristics & Software .................................................................................... 3 3.2. Cables ....................................................................................................................................... 3 3.3. EUT Hardware .......................................................................................................................... 4 3.4. Support Equipment ................................................................................................................... 4 3.5. Test Setup ................................................................................................................................. 4 4. Measurements Parameters ................................................................................................................ 5 4.1. Measurement Equipment Used to Perform Test ...................................................................... 5 4.2. Measurement & Equipment Setup ............................................................................................ 6 4.3. Measurement Procedure .......................................................................................................... 6 4.4. Measurement Uncertainty ......................................................................................................... 6 5. Measurement Summary ..................................................................................................................... 7 6. Measurement Data ............................................................................................................................. 8 6.1. Antenna Requirement ............................................................................................................... 8 6.2. Operational Requirements ........................................................................................................ 8 6.3. UWB Bandwidth ........................................................................................................................ 9 6.4. Spurious Radiated Emissions ................................................................................................. 10 6.5. Radiated Emissions in GPS Bands ......................................................................................... 23 6.6. RMS Power in a 1 MHz Bandwidth ......................................................................................... 28 6.7. Peak Emissions in a 50 MHz Bandwidth ................................................................................ 30 6.8. Conducted Emissions Test Setup ........................................................................................... 32 6.9. Conducted Emissions Results ................................................................................................ 33 6.10. 99% Emissions Bandwidth .................................................................................................... 35 6.11. Public Exposure to Radio Frequency Energy Levels............................................................ 36 7. Test Site Description ........................................................................................................................ 38 8. Test Images ...................................................................................................................................... 39 8.1. Spurious and Harmonic Emissions - 10 kHz to 1 GHz Front .................................................. 39 8.2. Spurious and Harmonic Emissions - 10 kHz to 30 MHz Rear ................................................ 40 8.3. Spurious and Harmonic Emissions - 30 MHz to 1 GHz Rear ................................................. 41 8.4. Spurious and Harmonic Emissions - 1 to 18 GHz Front ......................................................... 42 8.5. Spurious and Harmonic Emissions - 1 to 18 GHz Rear .......................................................... 43 8.6. Spurious and Harmonic Emissions - 18 to 40 GHz Side ........................................................ 44 8.7. Frequency Stability Setup ....................................................................................................... 45 8.9. Conducted Emissions Test Setup ........................................................................................... 47 Page 2 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 1. Scope Issue Date: 8/7/2019 This test report certifies that the iRobot Corporation TerraTM t7 RLA-Y1 as tested, meets the FCC Part 15.250, Subpart C and ISED RSS-220 requirements. The scope of this test report is limited to the test sample provided by the client, only in as much as that sample represents other production units. If any significant changes are made to the unit, the changes shall be evaluated and a retest may be required. Revision R1 updates the RF Exposure exhibit. 2. Product Details 2.1. Manufacturer:
2.2. Product Name:
2.3. Model Number:
2.4. Serial Number:
2.5. Description:
2.6. Power Source:
2.7. Hardware Revision:
2.8. Software Revision:
2.9. Modulation Type:
2.10. Operating Frequency: CH 5 6.49 GHz Nominal 2.11. EMC Modifications: None iRobot Corporation TerraTM t7 RLA-Y1 EP1-573 The Terra RLA-Y1 is an autonomous robotic lawn mower. 36 Volt Rechargeable Battery N/A Navigation 0.5.2 Pulse Modulation, Frequency Hopping 3. Product Configuration 3.1 Operational Characteristics & Software Hardware Setup:
Install the batteries within the unit. Using a laptop and serial cable the unit was programmed to transmit a typical waveform used for communication in continuous mode (back to back mode). 3.2. Cables Cable Type Length Shield From To None Page 3 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 3. Product Configuration (cont.) 3.3. EUT Hardware Issue Date: 8/7/2019 Manufacturer Model/Part # / Options Serial Number Input Volts Freq
(Hz) Description/Function iRobot iRobot RLA-Y1 AXD-Y1 EP1-573 36 DC Battery BLE/WiFi Module:
FCC ID: UFEAXD-Y1 3.4. Support Equipment Manufacturer Model/Part #
Serial Number Description None 3.5. Test Setup Diagram OATS Ground Plane Drawing is not to scale EUT 3 meters1 HP 8449B or Miteq Preamp2 R&S FSW26 Spectrum Analyzer2 1 Measurement distance varies according to the measurement being made. 2 Equipment listed is representative of the equipment used. See the test equipment list for details. Page 4 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 4. Measurements Parameters 4.1. Measurement Equipment Used to Perform Test Issue Date: 8/7/2019 Device Manufacturer Model No. Serial No. Cal Due Interval EMI Receiver 9 kHz to 7 GHz Rohde & Schwarz ESR7 Spectrum Analyzer 9 kHz to 40 GHz Rohde & Schwarz FSV40 101156 100899 9/10/2020 2 Years 9/10/2020 2 Years Spectrum Analyzer 10 Hz to 40 GHz Rohde & Schwarz FSVR40 100909 5/3/2020 3 Years Spectrum Analyzer 3 Hz to 26.5 GHz Rohde & Schwarz FSW26 102044 9/13/2020 2 Years Bilog Antenna 30 to 2000 MHz Com-Power AC-220 25509 2/13/2022 3 Years Loop Antenna 9 kHz to 30 MHz Preamplifier 100 MHz to 7 GHz EMCO Miteq Preamplifier 100 MHz to 18 GHz Miteq Preamplifier 2 to 12 GHz JCA Preamplifier 1 to 26.5 GHz Hewlett Packard Preamplifier 18 to 40 GHz Miteq Horn Antenna 1 to 18 GHz ETS-Lindgren 6512 AFS3-
00100200-
10-15P-4 AMF-7D-
00101800-
30-10P JCA48-
4111B1 8449B JSD42-
21004200-40-
5P 3117 9309-1139 10/26/2019 3 Years 988773 4/17/2020 2 Years 1953081 4/16/2020 2 Years 7087S 4/17/2020 2 Years 3008A01323 9/11/2020 2 Years 649199/649219 11/1/2019 1 Year 00143292 3/21/2022 3 Years Horn Antenna 18-40 GHz Com Power AH-840 101032 10/9/2020 2 Years High Pass Filter 8 to 18 GHz Micro-Tronics HPM50107 G036 7/20/2019 1 Year 2.4 GHz Band Pass Filter Micro-Tronics BRM50702 150 1/23/2019 1 Year Barometer Control Company 4195 Cal ID# 236 4/3/2020 2 Years 1 ESR7 Firmware revision: V3.36, SP2 Date installed: 11/02/2017 2 FSV40 Firmware revision: V2.30 SP4, Date installed: 05/04/2016 3 FSVR40 Firmware revision: V2.23 SP1, Date installed: 08/19/2016 4 FSW26 Date installed: 10/28/2017 Firmware revision: V2.80, Previous V3.36, installed 05/16/2017. Previous V2.30 SP1, installed 10/22/2014. Previous V2.23, installed 10/20/2014. Previous V2.61, installed 04/04/2017. Page 5 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 4. Measurements Parameters (continued) 4.2. Measurement & Equipment Setup Test Dates:
Issue Date: 8/7/2019 Test Engineers:
Normal Site Temperature (15 - 35C): 21.6 Relative Humidity (20 -75%RH):
Frequency Range:
Measurement Distance:
EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth:
Detector Function:
5/14/2019, 6/25/2019, 7/8/2019, 7/9/2019, 8/1/2019 Brian Breault, Larry Stillings 35 30 kHz to 40 GHz 3 Meters 200 Hz 10 kHz to 150 kHz 9 kHz 10 to 30 MHz 120 kHz - 30 MHz to 1 GHz 1 MHz - Above 1 GHz 300 Hz 10 kHz to 150 kHz 30 kHz 10 to 30 MHz 300 kHz - 30 MHz to 1 GHz 3 MHz - Above 1 GHz Peak, Quasi-Peak, RMS &
CISPR Average 4.3. Measurement Procedure Test measurements were made in accordance FCC Parts 15.209, 15.250 Subpart C and ISED RSS-220, Issue 1 & A1. The test methods used to generate the data is this test report is in accordance with ANSI C63.10:2013, American National Standard for Testing Unlicensed Wireless Devices. 4.4. Measurement Uncertainty The following uncertainties are expressed for an expansion/coverage factor of K=2. RF Frequency (out of band) Radiated Emission of Transmitter to 100 GHz Radiated Emission of Receiver Temperature Humidity 1x10-8 4.55 dB 4.55 dB 0.91o C 5%
Page 6 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 5. Measurements Summary Issue Date: 8/7/2019 Test Requirement FCC Rule ISED Rule Requirement Requirement Test Report Section Result Comment Antenna Requirement 15.203 RSS-220 5.1 (b) 6.1 Compliant Operational Requirements 15.250 (a) RSS-220 6.2 Compliant Wideband Bandwidth 15.250 (b) RSS-220 2 RSS-220 5.1 6.3 Compliant RSS-220 3.4 6.4 Compliant Spurious Radiated Emissions 15.250 (d) (1) 15.209 Radiated Emissions in GPS Bands 15.250 (d) (2) RMS Power in a 1 MHz Bandwidth Peak Emissions in a 50 MHz Bandwidth 15.250 (d) (1) 15.250 (d) (3) RSS-220 5.3.1 (e) RSS-220 5.3.1 (d) RSS-220 5.3.1 (g) Conducted Emissions 15.207 RSS-GEN 6.5 Compliant 6.6 Compliant 6.7 Compliant 6.8 6.9 Compliant 99% Emission Bandwidth Radio Frequency Exposure N/A RSS-GEN 6.7 6.10 Compliant FCC OET Bulletin 65 1.1307 (b) (1) RSS-102, Issue 5 6.11 Compliant Page 7 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data Issue Date: 8/7/2019 6.1. Antenna Requirement (15.203, RSS-220 5.1 (b)) Requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply Result:
The antenna utilized by the device under test uses an on board u.fl connector to connect to the antenna. 6.2. Operational Requirements of the Device under Test (15.250 (a), RSS-220) Requirement: The -10 dB bandwidth of a device operating under the provisions of this section must be contained within the 5925 to 7250 MHz band under all conditions of operation including the effects from stepped frequency, frequency hopping or other modulation techniques that may be employed as well as the frequency stability of the transmitter over expected variations in temperature and supply voltage. Result:
Compliant 6.2.1 Frequency Stability over Temperature Marker Temp C Measured Frequency
-10 dB 15.250 Band Edges Frequency Band
(MHz) Lower Upper FMIN
(MHz) FMAX
(MHz) OATS Ambient
-20
-10 0
+10
+20
+30
+40
+50 6439.1 6552.0 6568.4 6395.6 6493.5 6493.5 6489.6 6481.6 6484.1 6483.1 6282.2 6454.0 6459.0 6332.2 6332.2 6333.2 6332.2 6333.2 6340.2 6337.2 6738.8 6649.9 6677.8 6459.0 6654.8 6653.8 6646.9 6629.9 6627.9 6628.9 5925 5925 5925 5925 5925 5925 5925 5925 5925 5925 7250 7250 7250 7250 7250 7250 7250 7250 7250 7250
-
-
1 2 3 4 5 6 7 8 Result Compliant Compliant Compliant Compliant Compliant Compliant Compliant Compliant Compliant Compliant Page 8 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.3. Wideband Bandwidth (15.250 (b), RSS-220 2, 5.1) Requirement: The -10 dB bandwidth of the fundamental emission shall be at least 50 MHz. Result:
Compliant 6.3.1. Measurement Data Values in GHz fM fL fH The highest emission peak 6.5669 10 dB below the highest peak 6.2822 10 dB above the highest peak 6.7388 Bandwidth Calculated: (fH - fL) 0.4565 6.3.2. Measurement Plot of 10 dB frequencies Page 9 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (1), 15.209, RSS-220 3.4) Requirement: The radiated emissions at or below 960 MHz from a device operating under the provisions of this section shall not exceed the emission levels in Section 15.209. The radiated emissions above 960 MHz from a device operating under the provisions of this section shall not exceed the following average limits when measured using a resolution bandwidth of 1 MHz:
Frequency
(MHz) 960 - 1610 1610 - 1990 1990 - 3100 3100 5925 5925 7250 7250 10,600 Above 10,600 EIRP
(dBm)
-75.3
-63.3
-61.3
-51.3
-41.3
-51.3
-61.3 EIRP at 3 Meters
(dBV/m) 19.9 31.9 33.9 43.9 53.9 43.9 33.9 Spurious Radiated Emissions (RSS-220 5.3.1 (d)) Requirement: The radiated emissions at or below 960 MHz from a device shall not exceed the limits in Section 3.4. The radiated emissions above 960 MHz from a device shall not exceed the following average limits when measured using a resolution bandwidth of 1 MHz:
Frequency
(MHz) 960 - 1610 1610 4750 4750 10,600 Above 10,600 EIRP
(dBm)
-75.3
-70.0
-41.3
-61.3 EIRP at 3 Meters
(dBV/m) 19.9 25.2 53.9 33.9 Page 10 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (1), 15.209, RSS-220 3.4 continued) Radiated Emissions Field Strength Limits at 3 Meters (Section 15.250 (d),15.209) Frequency
(MHz) 0.009 to 0.490 0.490 to 1.705 1.705 - 30 30 - 88 88 - 216 216 - 960 960 - 40,000 Field Strength Field Strength
(V/m) 2,400/F 24,000/F 30 100 150 200 500
(dBV/m) 128.5 to 93.8 73.8 to 63 69.5 40 43.5 46 54 Test Notes: Refer to Section 4.1 for the test equipment used. Frequency Range:
Measurement Distance:
EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth
(minimum):
Detector Function:
30 kHz to 40 GHz 3 Meters 200 Hz 10 kHz to 150 kHz 9 kHz 150 kHz to 30 MHz 120 kHz - 30 MHz to 1 GHz 1 MHz - Above 1 GHz 300 Hz 10 kHz to 150 kHz 30 kHz 150 kHz to 30 MHz 300 kHz - 30 MHz to 1 GHz 3 MHz - Above 1 GHz Peak, Quasi-Peak & Average Note:
The narrow band spikes in the frequency range of 960 MHz to 1.610 GHz are due to the digital circuitry and subjected to the spurious emissions limit in Part 15.209 of 500 V / m at 3 meters or 54 dBV / m. Page 11 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. There were no measurable emissions below 960 MHz on our 3 Meter OATS. 6.4.1.1 Parallel Measurement Antenna 30 to 150 kHz Page 12 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. There were no measurable emissions below 960 MHz on our 3 Meter OATS. 6.4.1.2 Perpendicular Measurement Antenna 30 to 150 kHz Page 13 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. There were no measurable emissions below 960 MHz on our 3 Meter OATS. 6.4.1.3 Ground Parallel Measurement Antenna 30 to 150 kHz Page 14 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. There were no measurable emissions below 960 MHz on our 3 Meter OATS. 6.4.1.4 Parallel Measurement Antenna 150 kHz to 30 MHz Page 15 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. There were no measurable emissions below 960 MHz on our 3 Meter OATS. 6.4.1.5 Perpendicular Measurement Antenna 150 kHz to 30 MHz Page 16 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. There were no measurable emissions below 960 MHz on our 3 Meter OATS. 6.4.1.6 Ground Parallel Measurement Antenna 150 kHz to 30 MHz Page 17 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. 6.4.1.7 Horizontal Polarity 30 to 960 MHz Page 18 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (5), 15.209, RSS-220 3.4 continued) 6.4.1. 30 kHz to 960 MHz, measured at 3 Meters The device was prescreened in our 3 Meter Semi-Anechoic Chamber. 6.4.1.8 Vertical Polarity 30 to 960 MHz Page 19 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (1), RSS-220 5.3.1(d)) 6.4.2. 960 MHz to 8 GHz Horizontal at 1 Meter (Directional 16M PRF) 6.4.3. 960 MHz to 8 GHz Vertical at 1 Meter (Directional 16M PRF) Page 20 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (1), RSS-220 5.3.1 (d) continued) 6.4.4. 8 to 18 GHz Horizontal at 1 Meter 6.4.5. 8 to 18 GHz Vertical at 1 Meter Page 21 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.4. Spurious Radiated Emissions (15.250 (d) (1), RSS-220 5.3.1 (d) continued) 6.4.6. 18 to 40 GHz Horizontal at 0.3 Meter 6.4.7. 18 to 40 GHz Vertical at 0.3 Meter Page 22 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.5. Spurious Radiated Emissions (RSS-220 5.3.1 (d) continued) Requirement: The radiated emissions at or below 960 MHz from a device shall not exceed the limits in Section 3.4. The radiated emissions above 960 MHz from a device shall not exceed the following average limits when measured using a resolution bandwidth of 1 MHz:
The RMS average measurement is based on the use of a spectrum analyzer with a resolution bandwidth of 1 MHz, an RMS detector, and a 1 millisecond or less averaging time. The EIRP in terms of dBm, can be converted to a field strength, in dBV/m at 3 Meters by adding 95.2. Frequency
(MHz) 960 - 1610 1610 4750 4750 10,600 Above 10,600 EIRP
(dBm)
-75.3
-70.0
-41.3
-61.3 EIRP at 3 Meters
(dBV/m) 19.9 25.2 53.9 33.9 Frequency Range:
Measurement Distance:
EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth Detector Function:
960 MHz to 8 GHz 1 Meter 1 MHz 10 MHz RMS 1 mS Average as defined in Annex Section 4(b) Notes:
Measurements made from 960 MHz to 8 GHz were made in a semi-
anechoic chamber at 1 Meter using a -9.54 dB distance offset was programmed into the spectrum analyzer. Measurement data above 8 GHz for Channel 5 is provided in plots 6.4.8 to 6.4.13 on the previous pages. The narrow band spikes in the frequency range of 960 MHz to 4.75 GHz are due to the digital circuitry and subjected to the spurious emissions limit of 500 V / m at 3 meters or 54 dBV / m. Page 23 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.5. Spurious Radiated Emissions (RSS-220 5.3.1 (d)) continued) 6.5.1. 960 MHz to 8 GHz Horizontal at 1 Meter 6.5.2. 960 MHz to 8 GHz Vertical at 1 Meter Page 24 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.5. Spurious Radiated Emissions in GPS Bands (15.250 (d) (2), RSS-220 5.3.1 (e)) Requirement: In addition to the radiated emission limits specified in the table in paragraph (d) of this section, UWB transmitters operating under the provisions of this section shall not exceed the following average limits when measured using a resolution bandwidth of no less than 1 kHz:
Frequency
(MHz) 1164 - 1240 1559 - 1610 EIRP
(dBm)
-85.3
-85.3 EIRP at 3 Meters
(dBV/m) 9.9 9.9 6.5.1. Measurement & Equipment Setup EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth:
Detector Function:
1 kHz 10 kHz RMS 6.5.2. Test Procedure Test measurements were made in accordance with ANSI C63.10:2013, American National Standard for Testing Unlicensed Wireless Devices. 6.5.3. 1164 to 1240 MHz & 1559 to 1610 MHz There were no broadband emissions related to the UWB transmitter. Measured signals were narrowband and related to the microprocessor / clocks and do not fall under the requirements of this section. At 3 Meters the -85.3 dBm limit is converted to a field strength limit of 9.9 dBuV/m using a distance correction factor of 95.2. A distance correction factor of -9.54 dB was entered into the analyzer as an offset since the measurements were made at 1 meter. The narrow band spikes in the frequency ranges of 1164 to 1240 MHz and 1559 to 1610 MHz are due to the digital circuitry and subjected to the spurious emissions limit in Part 15.209 of 500 V / m at 3 meters or 54 dBV / m. Page 25 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.5. Spurious Radiated Emissions in GPS Bands (15.250 (d) (2), RSS-220 5.3.1 (e)) 6.5.2 1164 to 1240 MHz Band 6.5.2.1 Horizontal Measurement Polarity 1164 to 1240 MHz 6.5.2.2 Vertical Measurement Polarity 1164 to 1240 MHz Page 26 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.5. Spurious Radiated Emissions in GPS Bands (15.250 (d) (2), RSS-220 5.3.1 (e)) 6.5.3 1559 to 1610 MHz Band 6.5.3.1 Horizontal Measurement Polarity 1559 to 1610 MHz 6.5.3.2 Vertical Measurement Polarity 1559 to 1610 MHz Page 27 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.6. RMS Power in a 1 MHz Bandwidth (15.250 (d) (1), RSS-220 5.3.1 (d)) Requirement: The radiated emissions above 960 MHz from a device operating under the provisions of this section shall not exceed the following average limits when measured using a resolution bandwidth of 1 MHz:
The RMS average measurement is based on the use of a spectrum analyzer with a resolution bandwidth of 1 MHz, an RMS detector, and a 1 millisecond or less averaging time. The EIRP in terms of dBm, can be converted to a field strength, in dBV/m at 3 Meters by adding 95.2. Frequency
(MHz) 5925 - 7250 EIRP
(dBm)
-41.3 EIRP at 3 Meters
(dBV/m) 53.9 Frequency Range:
Measurement Distance:
EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth Detector Function:
6 to 7 GHz 3 Meters 1 MHz 10 MHz RMS 1 mS Average Page 28 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.6. RMS Power in a 1 MHz Bandwidth (15.250 (d) (1), RSS-220 5.3.1 (d)) Requirement: The limit for operation in the 5925 to 7250 MHz band is -41.3 dBm EIRP. Frequency
(GHz) Amplitude1 Limit Margin Ant Ant Polarity Height Turntable Azimuth Result
(dBV/m)
(dBV/m)
(dB) H/V cm Deg 50.50 6.510 Compliant Notes: 1 Antenna Factor (AF), Cable Factor (CF) and External Preamplifier Gain (PAG) have been entered into the analyzer as transducer factors. 53.90
-3.40 194 58 V Equation (22) from ANSI C63.10-2013, EIRP = Emeas + 20 log (dmeas) 104.7; dmeas = 3 EIRP (dBm) = Emeas (dBV/m) 95.2 Frequency
(GHz) 6.510 Amplitude1
(dBm) EIRP
-44.70 Limit
(dBm) EIRP
-41.30 Margin
(dB)
-3.40 Ant Ant Polarity Height Turntable Azimuth Result H/V V cm 194 Deg 58 Compliant 6.6.1. Plot of RMS Power at 3 Meters (Directional 16M PRF) Page 29 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.7. Peak Emissions in a 50 MHz Bandwidth (15.250 (d) (3), RSS-220 5.3.1 (g)) Requirement: There is a limit on the peak level of the emissions contained within a 50 MHz bandwidth centered on the frequency at which the highest radiated emission occurs, fM. That limit is 0 dBm EIRP. The EIRP in terms of dBm, can be converted to a field strength, in dBV/m at 3 Meters by adding 95.2. Frequency
(MHz) 5925 - 7250 EIRP
(dBm) 0 EIRP at 3 Meters
(dBV/m) 95.2 Frequency Range:
Measurement Distance:
EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth Detector Function:
6 to 7 GHz 3 Meters 50 MHz 80 MHz Peak, Max Held Page 30 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.7. Peak Emissions in a 50 MHz Bandwidth (15.250 (d) (3), RSS-220 5.3.1 (g)) Requirement: There is a limit on the peak level of the emissions contained within a 50 MHz bandwidth centered on the frequency at which the highest radiated emission occurs, fM. That limit is 0 dBm EIRP. Frequency
(GHz) Amplitude1 Limit Margin Ant Ant Polarity Height Turntable Azimuth Result
(dBV/m)
(dBV/m)
(dB) H/V cm Deg 89.40 6.491 Compliant Notes: 1 Antenna Factor (AF), Cable Factor (CF) and External Preamplifier Gain (PAG) have been entered into the analyzer as transducer factors. 95.20
-5.80 194 58 V Equation (22) from ANSI C63.10-2013, EIRP = Emeas + 20 log (dmeas) 104.7; dmeas = 3 EIRP (dBm) = Emeas (dBV/m) 95.2 Frequency
(GHz) 6.491 Amplitude1
(dBm) EIRP
-5.80 Limit
(dBm) EIRP 0.00 6.7.1 Plot of Peak Power at 3 Meters Margin
(dB)
-5.80 Ant Ant Polarity Height Turntable Azimuth Result H/V V cm 194 Deg 58 Compliant Page 31 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) 6.8 Conducted Emissions Test Setup Issue Date: 8/7/2019 6.8.1. Regulatory Limit: FCC Part 15.207, RSS-Gen Frequency Range
(MHz) 0.15 to 0.50 0.50 to 5.0 5.0 to 30.0 Limits
(dBV) Quasi-Peak 66 to 56*
56 60 Average 56 to 46*
46 50
* Decreases with the logarithm of the frequency. 6.8.2 Measurement Equipment and Software Used to Perform Test Device Manufacturer Model No. Serial No. Cal Due EMI Receiver Hewlett Packard RF Filter Section Hewlett Packard EMI Receiver Rohde & Schwarz LISN EMCO 8546A 85460A ESR7 3825/2 3330A00115 9/12/2020 3325A00121 9/12/2020 101156 9/10/2020 9109-1860 9/10/2019 Manufacturer Software Description Title/Model #
Rev. Compliance Worldwide Test Report Generation Software Test Report Generator 1.0 6.8.3. Measurement & Equipment Setup Test Date:
Test Engineer:
Site Temperature (C):
Relative Humidity (%RH):
Frequency Range:
EMI Receiver IF Bandwidth:
EMI Receiver Avg Bandwidth:
Detector Functions:
8/1/2019 Mark R. McSweeney 22.2 45.3 0.15 MHz to 30 MHz 9 kHz 30 kHz Peak, Quasi-Peak. & Average 6.8.4. Test Procedure Test measurements were made in accordance with ANSI C63.4-2014, Standard Methods of Measurement of Radio Noise Emissions from Low-Voltage Electrical and Electronics Equipment in the Range of 9 kHz to 40 GHz. Page 32 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.9 Conducted Emissions Test Results 6.9.1. 120 Volts, 60 Hz Phase Frequency
(MHz) Pk Amp
(dBV) QP Amp
(dBV) QP Limit
(dBV) QP Margin
(dB) Avg Amp
(dBV) Avg Limit
(dBV) Avg Margin
(dB) Comments
.1860
.2018
.2805
.3053
.3728
.4043
.4650
.5055
.5573
.6068
.6540
.7103
.7733
.8093
.8385
.8835
.9105
.9645
.9825 1.0118 1.2143 1.4145 2.5755 4.6703 9.4988 14.9528 15.6615 19.5788 23.1315 29.5035 51.81 53.16 44.32 46.17 40.62 43.68 42.60 43.88 38.96 43.28 42.52 39.26 41.41 43.82 43.23 40.68 40.55 42.27 43.19 44.63 45.16 45.43 46.06 41.69 54.18 41.97 41.76 25.78 24.04 27.09 50.09 50.60 41.69 40.89 36.52 41.24 41.10 40.79 36.30 41.16 40.45 34.94 37.41 41.21 40.82 35.53 37.91 38.93 38.52 42.27 42.31 43.01 40.31 37.23 46.92 35.18 35.59 20.16 17.83 20.12 64.21 63.54 60.80 60.10 58.44 57.76 56.60 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 60.00 60.00 60.00 60.00 60.00 60.00
-14.12
-12.94
-19.11
-19.21
-21.92
-16.52
-15.50
-15.21
-19.70
-14.84
-15.55
-21.06
-18.59
-14.79
-15.18
-20.47
-18.09
-17.07
-17.48
-13.73
-13.69
-12.99
-15.69
-18.77
-13.08
-24.82
-24.41
-39.84
-42.17
-39.88 31.73 37.19 31.20 27.42 22.37 25.48 26.07 27.51 20.64 26.89 24.92 22.60 21.68 25.82 23.71 19.54 21.35 21.48 21.85 25.81 27.92 28.85 20.82 23.38 36.61 26.95 27.67 11.95 13.22 13.69 54.21 53.54 50.80 50.10 48.44 47.76 46.60 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 50.00 50.00 50.00 50.00 50.00 50.00
-22.48
-16.35
-19.60
-22.68
-26.07
-22.28
-20.53
-18.49
-25.36
-19.11
-21.08
-23.40
-24.32
-20.18
-22.29
-26.46
-24.65
-24.52
-24.15
-20.19
-18.08
-17.15
-25.18
-22.62
-13.39
-23.05
-22.33
-38.05
-36.78
-36.31 Page 33 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.9. Conducted Emissions Test Results (continued) 6.9.2. 120 Volts, 60 Hz Neutral Frequency
(MHz) Pk Amp
(dBV) QP Amp
(dBV) QP Limit
(dBV) QP Margin
(dB) Avg Amp
(dBV) Avg Limit
(dBV) Avg Margin
(dB) Comments
.1950
.2670
.2918
.3908
.4875
.5865
.6833
.7800
.8768
.9758 1.1715 2.4698 4.5060 9.4605 14.7818 16.3500 20.9760 25.5368 53.44 47.18 48.90 41.05 42.89 35.46 39.56 40.95 41.25 46.69 46.88 46.32 43.24 55.08 42.04 42.79 30.90 23.27 49.41 45.07 44.58 36.04 37.88 27.98 28.05 33.34 38.61 44.23 44.14 41.21 38.78 48.94 36.27 37.03 23.87 14.29 63.82 61.21 60.47 58.05 56.21 56.00 56.00 56.00 56.00 56.00 56.00 56.00 56.00 60.00 60.00 60.00 60.00 60.00
-14.41
-16.14
-15.89
-22.01
-18.33
-28.02
-27.95
-22.66
-17.39
-11.77
-11.86
-14.79
-17.22
-11.06
-23.73
-22.97
-36.13
-45.71 34.29 34.40 32.01 19.91 20.85 10.74 14.88 15.22 21.72 26.03 26.81 25.01 25.47 38.61 27.54 30.80 18.65 6.63 53.82 51.21 50.47 48.05 46.21 46.00 46.00 46.00 46.00 46.00 46.00 46.00 46.00 50.00 50.00 50.00 50.00 50.00
-19.53
-16.81
-18.46
-28.14
-25.36
-35.26
-31.12
-30.78
-24.28
-19.97
-19.19
-20.99
-20.53
-11.39
-22.46
-19.20
-31.35
-43.37 Page 34 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) 6.10. 99% Emission Bandwidth (RSS-GEN 6.7) Issue Date: 8/7/2019 Requirement: The occupied bandwidth shall be reported for all equipment in addition to the specified bandwidth required in the applicable RSSs RSS-Gen, Section 6.7. Test Note:
The resolution bandwidth (RBW) shall be in the range of 1% to 5% of the actual occupied / x dB bandwidth and the video bandwidth (VBW) shall not be smaller than three times the RBW value. Video averaging is not permitted. The detector of the spectrum analyzer shall be set to Sample. However, a peak, or peak hold, may be used in place of the sampling detector since this usually produces a wider bandwidth than the actual bandwidth (worst-case measurement). Use of a peak hold (or Max Hold) may be necessary to determine the occupied / x dB bandwidth if the device is not transmitting continuously. 6.10.1 Plot of 99% Emission Bandwidth Page 35 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.11. Public Exposure to Radio Frequency Energy Levels (1.1307 (b)(1)) 6.11.1 RF Exposure for devices that operate above 6 GHz Requirements: 2.1093(b): A portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. 2.1093 (d): Portable devices that transmit at frequencies above 6 GHz are to be evaluated in terms of the MPE limits specified 47 CFR 1.1310. Measurements and calculations to demonstrate compliance with MPE Field strength or power density limits for device operating above 6 GHz should be made at a minimum distance of 5 cm from the radiating source. 1.1310, Table 1: Limits for Maximum Permissible Exposure (MPE), Section (B):
Limits for General Population/Uncontrolled Exposure for devices that operate between 1500 to 100,000 MHz is 1.0 mW/cm2 using a 30 minute averaging time. ISED RSS-102, Issue 5, Section 3: Devices operating above 6 GHz regardless of the separation distance shall undergo an RF Exposure evaluation using IEEE C95.3. ISED RSS-102 Section 4 Table 4 RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment) above 6000 MHz the limit is 10 W/m2 using an averaging time of 6 minutes. Center MPE DUT Output DUT Frequency Distance
(GHz)
(cm) Power
(dBm) Antenna Gain (dBi) Power Density FCC Limit ISED Limit 6.492
(1) 5
(2)
-5.80
(3) 0.0
(4) 0.0008372 0.0083724
(5) 1
(6) 10
(mW/cm2)
(W/m2)
(mW/cm2)
(W/m) PD =
OP + AG
(4 x x d) 1. Reference CFR 2.1093(b): For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 5 centimeters of the body of the user. 2. Measured Peak Power at 3 Meters from Section 6.7 of this test report. 3. Antenna Gain included in the measured values of Section 6.7 4. Power density is calculated from field strength measurement and antenna gain. 5. Reference CFR 1.1310, Table 1: Limits for Maximum Permissible Exposure (MPE), Section (B): Limits for General Population/Uncontrolled Exposure. 6. Reference IC RSS-102 Section 4 Table 4 RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment) above 6000 MHz the limit is 10 W/m2 Page 36 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 6. Measurement Data (continued) Issue Date: 8/7/2019 6.11. Public Exposure to Radio Frequency Energy Levels (1.1307 (b)(1)) 6.11.2 RF Exposure for devices with simultaneous operation Requirements: For devices that contain multiple transmitters that may operate simultaneously an RF Exposure evaluation for that simultaneous transmission shall be performed. The EUT contains an WB transmitter operating at ~ 6.5 GHz, and a BLE/WiFi Module operating in the 2.4 GHz and 5 GHz bands under FCC ID: UFEAXD-Y1. Using the worst case data for the UWB and WiFi radios an estimation of RF Exposure at 5 cm has been calculated in the table below. The BLE and 2.4 GHz WiFi share the same antenna and the 2.4 GHz and 5 GHz radios cannot be operated simultaneously as described in the modular filing. Worse Case for the 2.4 GHz Radio was 802.11n-HT20 Mode of operation at 2.412 MHz. Center MPE Frequency Distance
(GHz)
(cm) DUT Peak Output Power
(dBm) DUT Antenna Gain (dBi) 6.491 2.412
(1) 5 20
(2)
-5.80 17.50 Power Density FCC Limit
(mW/cm2) ISED Limit
(W/m)
(3) 0.0 3.2
(mW/cm2)
(W/m2)
(4) 0.0008372 0.0083724 0.0231063 0.2310629 SUM 0.0239435 0.2394353
(5) 1 1 1
(6) 10 10 10 Worse Case for the 5 GHz Radio was 802.11n-HT20 Mode of operation at 5.500 MHz. Center MPE Frequency Distance
(GHz)
(cm) DUT Peak Output Power
(dBm) DUT Antenna Gain (dBi) 6.491 5.500
(1) 5 20
(2)
-5.80 17.50
(3) 0.0 3.51 SUM Power Density FCC Limit
(mW/cm2) ISED Limit
(W/m)
(mW/cm2)
(W/m2)
(4) 0.0008372 0.0083724 0.0251033 0.2510326 0.0259405 0.2594050
(5) 1 1 1
(6) 10 10 10 Page 37 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 7. Test Site Description Issue Date: 8/7/2019 Compliance Worldwide is located at 357 Main Street in Sandown, New Hampshire. The test sites at Compliance Worldwide are used for conducted and radiated emissions testing in accordance with the Federal Communications Commission (FCC) and Industry Canada standards. Through our American Association for Laboratory Accreditation (A2LA) ISO Guide 17025:2005 Accreditation our test sites are designated with the FCC (designation number US1091), Industry Canada (file number IC 3023A-1) and VCCI (Member number 3168) under registration number A-0274. Compliance Worldwide is also designated as a Phase 1 CAB under APEC-MRA (US0132) for Australia/New Zealand AS/NZS CISPR 22, Chinese-Taipei (Taiwan) BSMI CNS 13438 and Korea (RRA) KN 11, KN 13, KN 14-1, KN 22, KN 32, KN 61000-6-3, KN 61000-6-4. The radiated emissions test site is a 3 and 10 meter enclosed open area test site (OATS). Personnel, support equipment and test equipment are located in the basement beneath the OATS ground plane. The conducted emissions site is part of a 16' x 20' x 12' ferrite tile chamber and uses one of the walls for the vertical ground plane. A second conducted emissions site is also located in the basement of the OATS site with a 2.3 x 2.5 meter ground plane and a 2.4 x 2.4 meter vertical wall. Both sites are designed to test products or systems 1.5 meters W x 1.5 meters L x 2.0 meters H, floor standing or table top. Page 38 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.1. Spurious and Harmonic Emissions 30 kHz to 1 GHz Front Issue Date: 8/7/2019 Page 39 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.2. Spurious and Harmonic Emissions 30 kHz to 30 MHz Rear Issue Date: 8/7/2019 Page 40 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.3. Spurious and Harmonic Emissions 30 MHz to 1 GHz Rear Issue Date: 8/7/2019 Page 41 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.4. Spurious and Harmonic Emissions 1 to 18 GHz Front Issue Date: 8/7/2019 Page 42 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.5. Spurious and Harmonic Emissions 1 to 18 GHz Rear Issue Date: 8/7/2019 Page 43 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.6. Spurious and Harmonic Emissions 18 to 40 GHz Side Issue Date: 8/7/2019 Page 44 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.7. Frequency Stability (Setup) Issue Date: 8/7/2019 Page 45 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images 8.8. Frequency Stability (Setup) Issue Date: 8/7/2019 Page 46 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images (continued) 8.9. Conducted Emissions, Front View Issue Date: 8/7/2019 Page 47 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com Test Number: 275-19R1 8. Test Images (continued) 8.10. Conducted Emissions, Rear View Issue Date: 8/7/2019 Page 48 of 48 Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445 www.complianceworldwide.com
This product uses the FCC Data API but is not endorsed or certified by the FCC