Network Relay Point (NRP) NIC 440 Labeling Product Requirements Silver Spring Networks 555 Broadway Street Redwood City, CA 94063 www.silverspringnet.com Network Relay Point (NRP) NIC 440 Labeling Product Requirements 24 March 2014 Silver Spring Networks 1 NRP NIC 440 Product Requirements Confidential Information of Silver Spring Networks, Inc., provided under nondisclosure obligations. Copyright 2014 Silver Spring Networks, Inc. All rights reserved. The following are registered trademarks of Silver Spring Networks, Inc: the Silver Spring Networks name and logo, CustomerIQ, GreenBox, GridScape, UtilityIQ, UtilOS. The following are trademarks of Silver Spring Networks, Inc: Altogether Brilliant, Connect to the Energy Network, Connect to The Everything Network, EnergyIQ, GreenIQ, MForm, MicroAP, Micromesh, NetworkIQ, SilverLink, SSNsor, The Everything Network, The Internet of Important Things. All other company and product names are used for identification purposes only and may be registered trademarks, trademarks, or service marks of their respective owners. Please consider the environment before printing this document. Customer Support Hours 5:00 AM - 6:00 PM US Pacific Time Telephone Toll free within the US and Canada:
1-888-SSN-9876
(1-888-776-9876) Non-toll-free: 1-650-839-4298 In Australia:
1300 706 769 Contact us on the Web: http://www.silverspringnet.com/services/customer-support/
9:00 AM - 9:00 PM Australia Eastern Time Email support@silverspringnet.com aus-support@silverspringnet.com NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 2 Network Relay Point (NRP) NIC 440 Labeling Product Requirements Contents Contents 1. About the Silver Spring Networks Network Relay Point (NRP) NIC . 2 References . 2 NIC Address Labeling. 2 NIC Labeling. 3 2. FCC and Industry Canada Government Guidelines . 5 Requirements . 5 Exigences d'Industrie Canada . 6 FCC and Industry Canada Guidelines for Devices Containing a Transmitter Module . 6 NIC 440 External Antenna Integration . 7 Safety Information . 8 General Electrical Safety . 8 Personal Protective Equipment (PPE) . 9 Fall Protection. 9 Shock Accident First Aid. 10 Network Relay Point (NRP) NIC 440 Labeling Product Requirements 24 March 2014 Silver Spring Networks 1 NRP NIC 440 Product Requirements 1 About the Silver Spring Networks Network Relay Point (NRP) NIC 1 About the Silver Spring Networks Network Relay Point (NRP) NIC TheNetworkRelayPoint(NRP)NICisanetworkinterfacecard(NIC)thatenablesmachine tomachinecommunicationover900MHzand2.4GHzISMbands.TheNICalso incorporatesan802.15.4compliantZigBeeradioforHomeAreaNetworking(HAN). Figure 1. Silver Spring Network Relay Point (NRP) NIC Top view Bottom view References Guidelinesfor64bitGlobalIdentifier(EUI64)RegistrationAuthority,IEEEStandards Association. NIC Address Labeling Forradioidentification,thestreetlightequipmentshallhaveanauxiliarylabelcontaining theSilverSpringNetworksNICaddresspresentedintext(16alphanumericdigits)andbar codeformats. BarCodeType=Code3of9 BarCodeFontSize=unknown FontType=unknown FontSize=unknown BarCodeLabelDimensions=1.0x1.5 BarCodeMaterialType=StaticDissipativePolyimide NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 2 NRP NIC 440 Product Requirements 1 About the Silver Spring Networks Network Relay Point (NRP) NIC Figure2showsanexampleoftheNICaddresslabel,whichisconsistentwithFCC requirementssetforthinChapter2FCCandIndustryCanadaGovernmentGuidelines,and containstheSilverSpringNetworkscorporatenameandNICEUI64address. Figure 2. Example of NIC address label for NIC 440 Silver Spring Networks 1234567890123456 Contains:
FCC ID: OWS-NIC441 IC: 5975A-NIC441 NIC Labeling TheNetworkRelayPoint(NRP)NIChasalabelrelevanttoNRPfinalassemblyandRMA:
theFCCandPartNumberlabelandtheSilverSpringNICaddresslabel.Bothlabelsare locatedonthebottomsideoftheNICPCA. TheFCCIDlabelis1x.375inches(2.5x1cm).Figure3showsanexampleoftheFCCID labelfoundontheNRPNIC Figure 3. Sample FCC ID label for the NRP NIC NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 3 NRP NIC 440 Product Requirements 1 About the Silver Spring Networks Network Relay Point (NRP) NIC Figure4showstheplacementofthelabels. Figure 4. Label locations on the Silver Spring NRP NIC Silver Spring part number MAC address Catalog number Model number FCC ID IC Certification NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 4 NRP NIC 440 Product Requirements 2 FCC and Industry Canada Government Guidelines 2 FCC and Industry Canada Government Guidelines Silver Spring Networks NRP NIC FCC ID: OWS-NIC441 IC: 5975A-NIC441 Requirements TheNetworkRelayPoint(NRP)networkinterfacecard(NIC)isREQUIREDtobe professionallyinstalledbyaproperlytrainedtechnician.Improperinstallationcouldvoid theusersauthoritytooperatetheequipment. ThisdevicecomplieswithPart15oftheFCCRulesandIndustryCanadalicenceexemptRSS standard(s).Operationissubjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference,and 2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation. Theantennaofthistransmittermustnotbecolocatedoroperatinginconjunctionwithany otherantennaortransmitter. Thedeviceshouldbeinstalledsothatpeoplewillnotcomewithin20cm(8in.)ofthe antenna. Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance couldvoidtheusersauthoritytooperatetheequipment. ThisequipmenthasbeentestedandfoundtocomplywithPart15oftheFCCRules.This equipmentgenerates,uses,andcanradiateradiofrequencyenergy,andifnotinstalledand usedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor televisionreception(whichcanbedeterminedbyturningtheequipmentoffandon),theuser isencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver isconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 5 NRP NIC 440 Product Requirements 2 FCC and Industry Canada Government Guidelines Exigences d'Industrie Canada Lacartedinterfacerseau(NIC)SilverSpringNetworkRelayPoint(NRP)DOITtre installeparuntechnicienayantreuuneformationadquate.Uneinstallationincorrecte peutannulerlautorisationdelutilisateurseservirdelquipement. LeprsentappareilestconformeauxCNRdIndustrieCanadaapplicablesauxappareils radioexemptsdelicence.Lexploitationestautoriseauxdeuxconditionssuivantes:
(1)lappareilnedoitpasproduiredebrouillage,et
(2)lutilisateurdelappareildoitacceptertoutbrouillageradiolectriquesubi,mmesile brouillageestsusceptibledencompromettrelefonctionnement. Lantennedecetmetteurnedoitpassetrouverproximitdeoufonctionnerenassociation avecuneautreantenneouunautremetteur. Ledispositifdoittreinstalldemanireempchertoutepersonnedeseretrouvermoins de20cm(8po)delantenne. Leschangementsoumodificationsapportssanslapprobationexpressedelautorit responsabledelaconformitpourrontentranerlannulationdelautorisationdutilisation decetquipement. FCC and Industry Canada Guidelines for Devices Containing a Transmitter Module ThefollowingisanextractfromFCCPART15UNLICENSEDMODULARTRANSMITTER APPROVAL,DA001407,Released:June26,2000,Section6describinglabelingrequirements fordevicescontainingamodulartransmitter. Section6.ThemodulartransmittermustbelabeledwithitsownFCCIDnumber,and,if theFCCIDisnotvisiblewhenthemoduleisinstalledinsideanotherdevice,thenthe outsideofthedeviceintowhichthemoduleisinstalledmustalsodisplayalabel referringtotheenclosedmodule.Thisexteriorlabelcanusewordingsuchasthe following:ContainsTransmitterModuleFCCID:XYZMODEL1orContainsFCCID:
XYZMODEL1.Anysimilarwordingthatexpressesthesamemeaningmaybeused.The Granteemayeitherprovidesuchalabel,anexampleofwhichmustbeincludedinthe applicationforequipmentauthorization,or,mustprovideadequateinstructionsalong withthemodulewhichexplainthisrequirement. Inthelattercase,acopyoftheseinstructionsmustbeincludedintheapplicationfor equipmentauthorization. ThefollowingisanextractfromRSSGEN,GeneralRequirementsandInformationforthe CertificationofRadioApparatus,Section3.2.1,describinglabelingrequirementsforahost deviceintegratingaradiomodule. Thehostdeviceshallbeproperlylabelledtoidentifythemoduleswithinthehostdevice. TheIndustryCanadacertificationlabelofamoduleshallbeclearlyvisibleatalltimeswhen installedinthehostdevice,otherwisethehostdevicemustbelabelledtodisplaythe IndustryCanadacertificationnumberofthemodule,precededbythewordsContains transmittermodule,orthewordContains,orsimilarwordingexpressingthesame meaning,asfollows:
NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 6 NRP NIC 440 Product Requirements 2 FCC and Industry Canada Government Guidelines ContainstransmittermoduleIC:XXXXXXYYYYYYYYYYY whereXXXXXXYYYYYYYYYYYisthemodulescertificationnumber. LextraitsuivantprovientduCahierdeschargessurlesnormesradiolectriques(CNR);
exigencesgnralesetinformationrelativeslacertificationdesappareilsradio,section 3.2.1,etdcritlesexigencesenmatiredtiquetagepourundispositifhteintgrantun moduleradio. Ledispositifhtedoittrecorrectementtiquetafindidentifierlesmodulesquil comprend. LtiquettedecertificationIndustrieCanadadunmoduledoittoujourstrebienvisiblelors delinstallationsurundispositifhte.Danslecascontraire,ledispositifhtedoittre tiquetdefaonafficherlenumrodecertificationIndustrieCanadadumodule,prcd delexpressionContainstransmittermoduleoudumotContains,oudune formulationsimilaireayantlammesignification.Parexemple:
ContainstransmittermoduleIC:XXXXXXYYYYYYYYYYY oXXXXXXYYYYYYYYYYYreprsentelenumrodecertificationdumodule. Theapplicantforequipmentcertificationofthemoduleshallprovidewitheachunitofthe moduleeitheralabelsuchasdescribedabove,oranexplanationandinstructionstotheuser astothehostdevicelabellingrequirements. Figure 5. Sample FCC ID label for devices containing an NRP NIC (NIC 440) Contains FCC ID: OWS-NIC441 IC: 5975A-NIC441 NIC 440 External Antenna Integration Thisradiotransmitter5975ANIC441hasbeenapprovedbyIndustryCanadatooperatewith theantennatypeslistedbelowwiththemaximumpermissiblegainandrequiredantenna impedanceforeachantennatypeindicated.Antennatypesnotincludedinthislist,havinga gaingreaterthanthemaximumgainindicatedforthattype,arestrictlyprohibitedforuse withthisdevice. Omnidirectionalantennas:3dBiat900MHz,4dBiat2.4GHz Leprsentmetteurradio(identifierledispositifparsonnumrodecertificationouson numrodemodlesilfaitpartiedumatrieldecatgorieI)atapprouvparIndustrie Canadapourfonctionneraveclestypesdantennenumrscidessousetayantungain admissiblemaximaletlimpdancerequisepourchaquetypedantenne.Lestypesdantenne noninclusdanscetteliste,oudontlegainestsuprieuraugainmaximalindiqu,sont strictementinterditspourlexploitationdelmetteur. Antennesomnidirectionnelles:3dBi900MHz,4dBi2.4GHz NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 7 NRP NIC 440 Product Requirements 2 FCC and Industry Canada Government Guidelines UnderIndustryCanadaregulations,thisradiotransmittermayonlyoperateusingan antennaofatypeandmaximum(orlesser)gainapprovedforthetransmitterbyIndustry Canada.Toreducepotentialradiointerferencetootherusers,theantennatypeanditsgain shouldbesochosenthattheequivalentisotropicallyradiatedpower(e.i.r.p.)isnotmore thanthatnecessaryforsuccessfulcommunication. ConformmentlarglementationdIndustrieCanada,leprsentmetteurradiopeut fonctionneravecuneantenneduntypeetdungainmaximal(ouinfrieur)approuvpour lmetteurparIndustrieCanada.Danslebutderduirelesrisquesdebrouillage radiolectriquelintentiondesautresutilisateurs,ilfautchoisirletypedantenneetson gaindesortequelapuissanceisotroperayonnequivalente(p.i.r.e.)nedpassepas lintensitncessaireltablissementdunecommunicationsatisfaisante. Safety Information WARNING: Severe shock and explosion hazard! Touching energized parts can result in massive equipment damage, and severe injury or death. Short-circuiting energized parts will result in blinding flash and explosion. Opening and closing electrical circuits can also produce dangerous and explosive arc flashes. Involuntary muscular reactions associated with electrical shock may result in other injuries. Observe the following safety guidelines. Carefulplanningofeveryjobisessential.Nothingshouldbetakenforgranted.Donottake chances!
Readandfollowallapprovedpoliciesandproceduresprovidedbyyouremployer associatedwiththeproceduresinthismanual. Theproceduresinthismanualmustonlybeperformedbyqualifiedworkersin accordancewithlocalutilitysafetypractices,utilityrequirements,andapplicableOSHA andNFPAstandards. Theinformationcontainedinthisdocumentisintendedtoaidqualifiedpersonnel,andis notareplacementforthepropertrainingrequiredtomakeapersonqualified. SilverSpringNetworksassumesnoliabilityforthecustomersfailuretofollowthese safetyguidelines. General Electrical Safety Performtheproceduresinthismanualinaccordancewithapplicableworkplace standardsestablishedbythefollowingagencies:
OccupationalSafetyandHealthAct(OSHA). TheNationalElectricalCodepublishedbytheNationalFireProtectionAssociation
(NFPA70). NationalElectricalManufacturersAssociation(NEMA). ElectronicsIndustriesAssociation(EIA). InsulatedPowerCableEngineersAssociation(IPCEA). NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 8 NRP NIC 440 Product Requirements 2 FCC and Industry Canada Government Guidelines AmericanNationalStandardsInstitute(ANSI).Wheneverpossible,deenergizeall circuitsorequipmentbeforeworkingonthem. Maintainaminimumclearanceof10feet(3meters)betweenlinepotentialandall unqualifiedpersonsatalltimes. Keepunauthorizedpeopleoutoftheworkarea.Beespeciallycautiousofchildren,who tendtobedrawntoworkactivity. DeterminingifacircuitisOFFcanbedifficultinsomeinstances.Checkforcircuitvoltage withanappropriatevoltmeterbeforeworkingonequipmentpresumedtohavebeen deenergized.Tiebreakers,doublethrowdisconnectswitches,automatictransfer switchesandemergencygeneratorscansupplypowerthroughanalternatecircuitor fromanothersource. 120Vcurrentcanbejustalethalashighervoltagesbecausecurrentflowthroughabody dependsuponthebodysresistance. Donottrustinsulationand/orweatherproofingonawireasprotectionfromshock. Useelectricallyinsulatedtools.Inspectportableelectricalequipmentortoolsfordefects andremoveanydefectivedevicesfromserviceimmediately.Allportableelectrical equipmentmusthaveGroundFaultCircuitInterrupter(GFCI)protection. Selecttherighttoolforthejob.Usetoolsproperly.Keeptoolsingoodworkingorder. Makesuretheworkareaisfreeofanyflammablematerial.Flammablevaporscanbe ignitedbyanarcflash. Keeptheworkareacleananddry.Clutteredworkareascauseaccidentsandinjuries. Providegoodlightingintheworkarea.Youcannotworksafelyifyoucannotseewhat youaredoing. Reportunsafeconditionsordefectiveequipmenttoyourimmediatesupervisor. Handlematerialcarefully.Liftandcarryproperly. Personal Protective Equipment (PPE) AlwayswearPersonalProtectiveEquipment(PPE),inaccordancewithOSHAandANSI standards. Weareyeprotectionandelectricallyinsulatedgloves.Testglovesinaccordancewith ANSIstandardsbeforeuse.Donotuseglovesthatdonotpassappropriatetest procedures. Wearprotectiveclothingsuchaslongsleeveshirtsandlongpantsmadeofflameresistant materials. Removealljewelry. Donotpassanyobjectstoorfromotherpersonsnotprotectedbyinsulatingplatformsor tested,electricallyinsulatedgloves. Fall Protection Whenperformingworkatanyelevation:
NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 9 NRP NIC 440 Product Requirements 2 FCC and Industry Canada Government Guidelines Alwaysuseafallprotectionsystem,inaccordancewithOSHAstandards,whenever performingworkatanyelevation. Neveruseconductors,guywires,pins,orcrossarmbraces,etc.tosupportyourweight. Wheneverusingaerialliftdevicessuchashoists,manlifts,vehiclemountedwork platformsandoverheadlifts,readandfollowthemanufacturersguidelinesforsafeand properoperation. Useladdersandscaffoldingonlyinaccordancewiththemanufacturersguidelines and/oraccordingtoOSHAstandards. Onlyuseladdersmadeofnonmetallic,nonconductivematerial.Theyshouldbethe propersizeandtypefortheworkintended.Inspectladdersforwearandbreakage. Removeanyoil,grease,orotherslipperymaterials. Donotsettheladderattoosteeportooshallowofanangle.Aruleofthumbistostand erectwithyourtoesagainstthebottomrailsoftheladder,withyourarmsextended straightout.Ifyoucansetyourpalmsontopoftherungthatisateyelevel,theladder shouldbeattheproperangle.Ifaladderanglelabelisprovided,followits recommendations. Iftheladderistoremaininplaceforanextendedperiod,secureitatthetop.Thesupport pointatthetopoftheladdershouldbeatleast24inches(60centimeters)wideto maintainsupportintheeventofsidewaysmovement.Forjobsofshortduration,havea fellowworkersupporttheladderatthebase. Evaluatealltaskstobeperformedfromaladderforpotentialfallhazards,suchas complextasksorsituationsthatrequireleaningfromthesideoftheladder. Theuseofscaffoldingoraworkplatformshouldbeconsideredasanalternativesolution insuchcases. Shock Accident First Aid Donottouchthevictimwithyourbarehands;usesomethingnonconductivetoseparate thevictimfromtheenergysource. Callforemergencymedicalhelpimmediately.Keepthevictimlyingdown,warm,and comfortableuntilhelparrives.Avoidmovingthevictimincaseofinjurytoneckorback. Positionanunconsciousvictimonasidetoletfluidsdrain. Checkthevictimsbreathingandheartbeat.Ifproperlytrained,applymouthtomouth resuscitationand/orCPRifnecessary. Removeconstrictingitemsfromthevictim,suchasshoes,belts,jewelry,andtightcollars;
theycouldcutoffcirculationifthevictimexperiencesswelling. Applywaterorsalineforafewminutestoanyburnsuntiltheskinreturnstonormal temperature.Donotattempttoremoveclothingthatisstucktoaburn.Ifpossible,elevate burnedareastoreduceswelling. Makesurethevictimreceivesprofessionalmedicalattention,eveniftheyfeelfine. Electricshockcancauseheartfailurehoursaftertheshockisreceived. NRP NIC 440 Product Requirements 24 March 2014 Silver Spring Networks 10