submitted | available | document details (if available) | source link |
---|---|---|---|
March 30 2015 | September 26 2015 |
various | User Manual | Users Manual | 1.18 MiB | March 30 2015 / September 26 2015 |
ODT Manual SEPTEMBER 7, 2014 LG Electronics Inc. Contents I. What is ODT?
II. Environment for ODT III. Function List IV. Function in detail LGE Confidential 1. What is ODT?
ODT(OCU Development Tool) is development tool for debugging, testing and analyzing for OCU OCU USB Interface Serial Communication ODT for PC 2 / 60 LGE Confidential 2. Environment for ODT OS: Windows 7 or later (We not support Windows XP) Development Tool: Visual Studio 2010 3 / 60 LGE Confidential 3. Function List Window Major Functionalities Main GNSS Call Data SIM SMS Audio Log DTC GNSS Information, Network Information, Filtering Logs, Power Status, Virtual Button, Telltale, QXDM Logging, GNSS Maker GNSS Information Call Control, Auto Answer, RF Information APN, QoS Setup SIM information, Virtual SIM Send SMS message, Receive SMS message. Play Prompt, Start/Stop Loopback System Logs, Service Logs, Debug Messages Display DTCs Status Configuration Set and Get OCUs Configuration Update SW upgrade of NAD, GNSS and Micom KML Convertor Generate KML file 4 / 60 LGE Confidential 4. Function - Main 5 / 60 LGE Confidential 4. Function - GNSS View > GNSS > GNSS Information : You can see information of GNSS and DR in detail using this function. 6 / 60 LGE Confidential 4. Function - Network View > Network > Call : You can see the network information and call using this function. 7 / 60 LGE Confidential 4. Function - Network View > Network > APN : You can get and set APN and QoS setup through this function. 8 / 60 LGE Confidential 4. Function - Network View > Network > SMS : You can send and receive the SMS message. 9 / 60 LGE Confidential 4. Function - Network View > Network > UICC : You can set and get all UICCs parameters. 10 / 60 LGE Confidential 4. Function System Information View > System Information : You can see and check all version of OCUs module. 11 / 60 LGE Confidential 4. Function DTC View > DTC : You can get, clear and mask DTC(Diagnostic Trouble Codes) of OCU. 12 / 60 LGE Confidential 4. Function Audio View > Audio : You can control the audio features of OCU using this function 13 / 60 LGE Confidential 4. Function Logs View > Logs : You can see all logs of OCU 14 / 60 LGE Confidential 4. Function Configuration View > Configuration > Configuration : You can set and get the configuration of OCU. 15 / 60 LGE Confidential 4. Function BUB (Backup Battery) View > BUB : You can get the BUB(Backup Battery)s status. 16 / 60 LGE Confidential 4. Function HW IO View > HW IO : You can control the LED of OCU and get the Microphones current. 17 / 60 LGE Confidential 4. Function KML Convertor View > KML Convertor : You can convert from the raw data of GNSS and Network to KML file to test and debug on Google Earth 18 / 60 LGE Confidential 4. Function Update View > KML Convertor : You can update NAD, Micom and GNSS of OUC using this function. 19 / 60 LGE Confidential 4. Function Help View > Help > About ODT : You can know the version and expire date of ODT through this function 20 / 60 LGE Confidential Part 15.21 statement
"Change or Modifications that are not expressly approved by the manufa cturer could void the user's authority to operate the equipment.
"In order to comply with RF Exposure requi rements the anten na or ra diating element of this device must be installed to ensure that it is at least 20cm from end users. The antenna supplied with this device must not exceed a maximum gain of -7dBi in the cellular band and -7dBi in the PCS band."
Part 15.105 statement This equipment has been tested and found to comply with the limit s for a class B digital device, pursuant to Part 15 of the FCC Rul es. T hese limit s are de signed to pro vide reasona ble protection ag ainst ha rmful interfere nce in a resid ential inst allation. This equi pment gene rates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee th at interferen ce will n ot occur in a particular in stallation. If this equipme nt do es cause h armful interferen ce or televisio n rec eption, which can b e determi ned by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or rel ocate the receiving antenn a. -Increase the se paration between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Part 15 Class B Compliance This device and its accessories comply with p art15 of FCC rule s. Operation is subject to the following two conditions:
(1) This device & its accessories may not cause harmful interference.
(2) This device & it s accessories must accept any interference received, including interference that may cause undesired operation. Installation This unit should only be installed by qualified personnel by . The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 30 cm between the radiator and any part of your body.
This product uses the FCC Data API but is not endorsed or certified by the FCC