all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User manual | Users Manual | 652.90 KiB | January 13 2020 | |||
1 2 |
|
Int Photos | Internal Photos | 1015.10 KiB | January 13 2020 | |||
1 2 |
|
Ext Photos | External Photos | 491.24 KiB | January 13 2020 | |||
1 2 |
|
Label | ID Label/Location Info | 315.05 KiB | January 13 2020 | |||
1 2 |
|
Agent Authorization Rev 1.0 | Cover Letter(s) | 21.06 KiB | January 13 2020 | |||
1 2 | BOM | Parts List/Tune Up Info | January 13 2020 | confidential | ||||
1 2 | Block Diagram | Block Diagram | January 13 2020 | confidential | ||||
1 2 |
|
FCC Short & Long Term Confidentiality | Cover Letter(s) | 96.06 KiB | January 13 2020 | |||
1 2 |
|
NTC1910194FV00 FCC ID Report DSS | Test Report | 4.86 MiB | January 13 2020 | |||
1 2 | Operation Description | Operational Description | January 13 2020 | confidential | ||||
1 2 |
|
RF EXPOSURE EVALUATION | RF Exposure Info | 164.16 KiB | January 13 2020 | |||
1 2 | SCH | Schematics | January 13 2020 | confidential | ||||
1 2 |
|
Test Setup | Test Setup Photos | 302.77 KiB | January 13 2020 | |||
1 2 |
|
NTC1911090FV00 FCC ID NFC | Test Report | 3.26 MiB | January 13 2020 |
1 2 | User manual | Users Manual | 652.90 KiB | January 13 2020 |
Document History Version M010-GUIDE01-V1-3 M010 Operational Guide Date: 3rd June 2019 Commercially confidential Uncontrolled when printed Details of change(s) Author(s) RS, RH, VB MW, SJ V1-0 V1-1 V1-2 V1-3 Initial release Added battery charging recommendations, and regulatory statements. Added implementation note about Vehicle transients. Added new compliance notes, NFC. DH, RS Storage battery recharge statement added, formatting changes, in vehicle use note added. Shuttle references updated except in log files GR Miura Systems 2019 Page 1 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 1 Introduction .................................................................................................................................. 4 2 M010 Features .............................................................................................................................. 5 3 Operating the M010 Terminal ...................................................................................................... 6 3.1 Introduction ........................................................................................................................... 6 3.2 Power and charging ............................................................................................................... 6 3.2.1 Turning the terminal ON ................................................................................................ 6 3.2.2 Turning the terminal OFF ............................................................................................... 6 3.2.3 Sleep ............................................................................................................................... 6 3.2.4 Charging the Battery ...................................................................................................... 6 3.2.5 Low Battery .................................................................................................................... 7 3.2.6 Battery usage guidelines ................................................................................................ 7 3.2.7 Implementation note: vehicle transients ...................................................................... 7 3.3 Bluetooth ............................................................................................................................... 8 3.3.1 Start up ........................................................................................................................... 8 3.3.2 Ready To Pair: ................................................................................................................. 8 3.3.3 Ready To Connect........................................................................................................... 8 3.3.4 Connected ...................................................................................................................... 8 3.4 Transaction Mode .................................................................................................................. 9 3.4.1 PIN Entry ......................................................................................................................... 9 3.4.2 PIN OK ............................................................................................................................. 9 3.4.3 PIN Incorrect .................................................................................................................. 9 3.4.4 Last Try ............................................................................................................................ 9 3.5 Contactless ............................................................................................................................ 9 3.5.1 Contactless transactions .............................................................................................. 10 3.6 Terminal Maintenance ........................................................................................................ 10 3.6.1 Security Check .............................................................................................................. 10 3.6.2 Software Update .......................................................................................................... 10 3.7 Error states .......................................................................................................................... 11 3.7.1 System Tampered ......................................................................................................... 11 3.7.2 Ready To Install ............................................................................................................. 11 4 ReviveTM ...................................................................................................................................... 12 4.1 Power up as Normal ............................................................................................................ 12 M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 2 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 4.2 System Restore .................................................................................................................... 12 4.3 Total Factory reset ............................................................................................................... 13 4.4 Terminal Diagnostics ........................................................................................................... 13 5 Functional Test ............................................................................................................................ 15 5.1.1 LCD Test ........................................................................................................................ 15 5.1.2 LED Test ........................................................................................................................ 15 5.1.3 Keypad Test .................................................................................................................. 16 5.1.4 Mag-Swipe Test ............................................................................................................ 16 5.1.5 Smart card Test ............................................................................................................. 16 5.1.6 Contactless card Test ................................................................................................... 16 5.1.7 Charger Test.................................................................................................................. 16 5.1.8 Charging Cradle Test .................................................................................................... 16 5.1.9 Bluetooth Test .............................................................................................................. 16 5.1.10 Apple Co-Processor Test ............................................................................................ 16 5.1.11 Hardware Functionality Test Completion ................................................................. 17 6 End-user Troubleshooting .......................................................................................................... 18 7 Filtering Process .......................................................................................................................... 19 8 Appendix A: Example Diagnostic Files ....................................................................................... 20 9 Appendix B: Regulatory Information ......................................................................................... 23 M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 3 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 1 Introduction This document provides general information about the operation of the M010 terminal and gives detailed instructions to be used as the basis for device filtering and fault diagnostics. The intention is to convey all necessary information about the operation of the terminal in one document. This document does not cover any operations which are controlled by third-party applications (either those running on the terminal or those running on the smart device). It is envisaged that the information in this document will then be used by Miura partners, in conjunction with other information they have about the system as a whole, to produce other documents / web-pages for end-users and teams within the partner's organisation. Appendix B contains regulatory information about the device. It is recommended that this information is added to all end-user documentation. It is mandatory that the Declaration of Conformity (or a link to it) should be included in the end-user documentation, along with a statement that the equipment meets the essential requirements of Directive 2014/53/EU. For example: This product is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The declaration of conformity may be consulted at www.miurasystems.com In addition, the name, registered trade name, or registered trade mark, and the postal address of the reseller or distributor should also be included in the user documentation. Storage requirements- battery charging The M010 terminal must be fully charged at least every 6 months whilst in storage in order to prevent undue load on the internal back-up battery. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 4 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 2 M010 Features Ref Feature 1 2 Charging LED Charging cradle contacts ReviveTM button 3 USB connector 4 Swipe slot 5 Power button 6 Contactless LEDs 7 Function key 8 OLED display 9 10 Cancel key 11 Enter key Clear key 12 13 Chip Card Slot Function Red LED indicates unit is charging Charging contacts for standard or fast charge cradles. From left: 5V; 5V fast charge; GND Pin-hole reset button used to activate the Revive feature USB Micro-B receptacle - used for charging / file transfer Reads magnetic stripe cards (stripe downwards and facing away from user) Used to power the terminal on and off and enter sleep mode Four LEDs indicate different stages of a contactless card transaction TBC Displays instructions for user Cancels actions including PIN entry Confirms actions including PIN entry D Deletes last PIN digit entered Reads chip cards (insert card with chip facing upwards) M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 5 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 3 Operating the M010 Terminal 3.1 Introduction This section covers the basic operation and use of the terminal. This covers power on and off, charging, basic Bluetooth connection, transaction PIN entry and terminal maintenance. The logos displayed in this document are configurable. This document assumes that the Miura (MPI) application is loaded and the default logos are still in use. 3.2 Power and charging 3.2.1 Turning the terminal ON To power up, the operator must push the power button or plug the terminal into a USB power source. The power-up sequence starts with the display of the boot logo whilst the terminal starts up. Once the terminal is ready to use, the Bluetooth icon will start to flash or stay solid at the top left corner of the display depending on whether the terminal has been paired with any smart device. The battery status indicator will be loaded on the top right corner of the display. When the terminal is powering up. When the terminal is ready to use. 3.2.2 Turning the terminal OFF To switch off a terminal the operator must press and hold the power button until the display shows Shutting Down and the display turns off. Once off, the terminal will not react to any key presses, except Power button and the ReviveTM switch. 3.2.3 Sleep The terminal can be put into sleep mode. In this mode the terminal's power consumption is very low
(and Bluetooth is switched off), but when it is woken it will be ready to use within a few seconds. The terminal will enter sleep mode if the power button is briefly pressed, or after a period of inactivity. The terminal will wake on any of the following activities:
Any key press USB charge cable inserted Smart-Card inserted Magnetic Stripe Card swiped M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 6 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 3.2.4 Charging the Battery The terminal is fitted with an internal rechargeable battery which cannot be removed or replaced. This battery should be charged for at least 3 hours when using the terminal for the first time or if the terminal has not been used for a long time. The battery is charged by plugging the terminal into either a computer or external USB adapter using the USB lead provided. Charging via a USB wall adaptor is faster but the adaptor must be capable of supplying at least 850mA (1A recommended). The battery may also be charged by placing the terminal into a Retail Comms Cradle (connected either to a computer or external USB power adapter), or into a Fast Charge Cradle or Fast Charge Rack which will allow the fastest charging time by using a 2A power supply. When the unit is charging and running normally the charging icon(
right hand corner of the display The battery status icon will also indicate the real time battery power.
) will be displayed in the top 3.2.5 Low Battery If the battery power goes below the configured Low Battery Threshold, the low battery warning screen will be displayed. If the battery power goes below a critical level the terminal will sleep until the charge has increased above this level. 3.2.6 Battery usage guidelines Keep the battery well-charged and do not let it discharge completely. Charge at normal room temperature (charging is disabled outside the range 0C-45C). Keep the terminal away from heat sources (such as heaters or direct sun-light) Fully charging the terminal every 6 months (even when not in use) is strongly recommended to prolong the lifetime of the battery. 3.2.7 Implementation note: In-vehicle use The 12V power supply in cars (which goes to the cigarette lighter port) is subject to large voltage transients generated by the vehicle. These must be filtered off by the 12V to 5V USB cigarette lighter adaptor. Only good quality power adaptors (for instance, those designed to meet ISO 7637-2) must be used. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 7 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 3.3 Bluetooth 3.3.1 Start up Once the terminal is ready to use, the Bluetooth icon and the battery status indicator will be displayed at left and right top corners of the display respectively and the terminal enters one of the following modes:
Ready To Pair Ready to Connect 3.3.2 Ready To Pair:
If the terminal has never been paired with any Bluetooth device previously, the terminal starts in Ready To Pair mode. The Bluetooth icon will be flashing once per second. In this mode the terminal will be discoverable by other Bluetooth devices. The remote Bluetooth device can now pair with the terminal. The terminal will remain in this state until the remote Bluetooth device successfully completes the pairing process, at which point it will drop to Ready To Connect mode. For most modern smart devices the numeric comparison pairing method will be used. This involves both devices displaying the same random number. The user should check that these numbers match and if so confirm on both devices. For the Miura terminal the green tick key is used for this. For older Bluetooth devices, PIN pairing may be used. If the user is prompted for a Bluetooth PIN during the pairing process, it will be the last 6 digits of the terminal's serial number. 3.3.3 Ready To Connect If the terminal has previously been paired with a Bluetooth device, and the pairing information is still available in the terminal, it will start in Ready To Connect mode. In this mode the terminal will allow connections with the paired Bluetooth device and will not be discoverable by other Bluetooth devices. In this state the Bluetooth icon will stay solid. To activate the Ready To Pair mode press and hold the ENTER() key until the Bluetooth Icon starts to flash. Once pairing is complete the old pair will be removed (this is the only way to remove old pairs). To exit Ready To Pair mode without making a new pair, press the CANCEL(X) key. The terminal will also exit Ready To Pair after a configurable time-out. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 8 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 3.3.4 Connected The terminal enters Connected mode once a Bluetooth connection is established with an application on the smart device. 3.4 Transaction Mode 3.4.1 PIN Entry If the terminal is expecting PIN entry from the user, the instructions will be displayed. Once PIN entry is complete, the user should press ENTER() key to continue. During PIN entry the user can press CLEAR () to delete the previous digit or CANCEL(X) to delete all the digits and re-start PIN entry. Pressing CANCEL(X) when no digits are entered will cancel the PIN entry. 3.4.2 PIN OK If the PIN is correct, the terminal will display PIN OK. 3.4.3 PIN Incorrect If the PIN is incorrect the terminal will display INCORRECT PIN for 2 seconds and request for Pin entry again. 3.4.4 Last Try If the user is attempting last try for Pin entry, the terminal will indicate ENTER PIN: (Last Try). Note: The Pin Entry instruction are language dependent and will change depending on the language configured. The Language can be configured from the application on the smart device. 3.5 Contactless Due to the compact nature of the device, and mandated range of the contactless antenna, it is likely that contactless cards placed in or near the mag-swipe slot will be read by the contactless interface if enabled. It is therefore suggested that the interface is only enabled when the customer has confirmed that they wish to make a contactless payment. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 9 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 3.5.1 Contactless transactions When the M010 is ready to take a contactless payment, the screen below will be displayed (with the relevant transaction amount shown). The contactless card should be introduced to the unit with the card centralised on the contactless logo on the screen. 3.6 Terminal Maintenance 3.6.1 Security Check The terminal automatically performs a full security check every 24 hrs. The terminal can be configured by the application to trigger this security test when the terminal is idle. During this time the Bluetooth will be switched off. The files that failed the security check will be removed from the terminal. 3.6.2 Software Update The software on the terminal can be updated by the application on the smart device. The software update will be transferred to the terminal over the Bluetooth, once this is complete the software update will start. The terminal will indicate if a software update is in progress and will report success/failure. If the software update fails, the operator has to acknowledge the failure by pressing ENTER() to proceed further. In the unlikely event that a software update fails, a Factory-reset (see ReviveTM section) may be required to make the terminal operational. Software update in progress. The terminal will display the success or failure message accordingly. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 10 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 3.7 Error states 3.7.1 System Tampered If the terminal identifies a tamper, the terminal will immediately close the Payment application aborting any transaction in progress. The tamper state is indicated on the display. A Tampered terminal should be returned for investigation. 3.7.2 Ready To Install The terminal will be in Ready To Install state if no application has been installed or has been deleted. A terminal in Ready to Install state should be returned for investigation. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 11 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 4 ReviveTM Miura products include a ReviveTM feature which is activated using a pin-hole reset switch, this is situated next to the power button. See M010 Features section point 7. Pressing the ReviveTM button will trigger a hardware reset, and the terminal will display the Revive Menu. This is best done when there is no external power applied, if external power has been applied the terminal will request to disconnect the external power. The end-user should use this feature if the terminal is running but is locked up and not responding to the power button. The ReviveTM Menu has three options, namely:-
Power up as Normal System Restore Total Factory Reset 4.1 Power up as Normal Selecting this option will reboot the terminal resulting in a complete hardware and software reset. 4.2 System Restore The System Restore option will restore the terminal to an earlier point in time. If the terminal becomes unresponsive to power button or is not running as expected and the 1st option in the revive menu was unsuccessful in recovering the terminal the System Restore option can be used. The terminal requires the operator to confirm the System Restore selection in order to avoid unintentional system restoration. Confirmation of the System Restore action. System Restore in progress. The terminal will display the success or failure message for the System Restore. If the system Restore process fails, the operator has to acknowledge the failure by pressing the ENTER() key. In the unlikely event that a system restore fails, the terminal may be in an unusable state. The operator should then try Total Factory Reset to recover the terminal. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 12 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 4.3 Total Factory reset The Total Factory Reset option allows the end-user to reset all software and configuration back to the state it was in when the terminal left the factory. This feature should be used if there are any issues with the terminal operation which could not be solved by a Reboot or System Restore. Following a successful Total Factory Reset, the user will need to repeat the pairing process, and the controlling application on the smart device will need to perform any software configuration and key injection required. The terminal requires the operator to confirm the Total Factory Reset selection in order to avoid unintentional factory reset operation. Confirmation of the Total Factory reset action. Factory Reset in progress. The terminal will accordingly display the success or failure message for the Total Factory Reset. If the Total factory reset process fails, the operator has to acknowledge the failure by pressing the ENTER() key. If the factory reset fails the terminal has to be returned for further investigation. 4.4 Terminal Diagnostics The ReviveTM button can also be used to activate the terminal's diagnostics facilities. This involves exporting operating system log files and running a built-in hardware functional test. It is not envisaged that this will be done by an end-user. The diagnostics state is entered by activating the ReviveTM button whilst holding the '0' key. Once the terminal has booted, it will export XXX-XXXXXX-Conf.txt, XXX-XXXXXX-Info.txt and XXX-XXXXXX-
Events.txt diagnostic files in the USB Mass Storage Device, where XXX-XXXXXX is the serial number of the terminal. Example contents and format of these files are described in Appendix A: Example diagnostics Files. When returning a terminal under RMA, these files should be returned as well. Once these files have been retrieved the USB cable can be removed and the terminal automatically starts the functional test, see the Functional Test section. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 13 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 Creating Terminal diagnostic data: This state is notified when the diagnostics state is entered by activating the pin-hole switch. Terminal diagnostics data exported in USB Mass Storage Device: Once the diagnostics log files have been created, the files will be exported in the Mass storage device. The files can be retrieved by connecting the USB lead to a computer. Unplugging USB lead after this will start functional tests. Failed to export Terminal diagnostics data in Mass storage device: If the terminal fails to export the diagnostics log files in mass storage device, the terminal will display a failure message. The terminal should be identified as a return under warranty and all details of the terminal and the fault recorded. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 14 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 5 Functional Test The Miura Operating System contains a built-in hardware functionality test which allows an operator to fully test the hardware. In order to perform the tests the following are required (and can be obtained from Miura):
A Miura test card with Mag-swipe and smartcard. A Miura Bluetooth responder. This is a modified terminal running specific software with a pre-
set Bluetooth address. A 5 Volt power supply, current limited to 1.5A. Equipment which can supply the voltage to the charge cradle contact points on the terminal. A small paper-clip (not a sharp object) to activate the pin-hole reset switch. The functional tests are activated when the USB lead is unplugged after the retrieval of the diagnostics files from USB Mass Storage Device (MSD). The following are general points for functional tests:
For each test, the instructions will be shown using the display . For a pass, the next test will be loaded For a fail, the operator has to acknowledge the failure by pressing ENTER() to continue to next test. Pressing CANCEL(X) when a Test has failed will abort the functional test. Some tests can be aborted by pressing CANCEL(X) Either way, a results text file of the form XXX-XXXXXX_Results.txt will be exported in the MSD. If any tests fail or are aborted, the final result will be fail If a test was aborted or performed incorrectly all tests must be repeated If all tests pass the final result will be pass. Where XXX-XXXXXX is the serial number of the terminal. NOTE: If tests are skipped or performed incorrectly (e.g. if a card was swiped badly or the Bluetooth responder was not switched on), the terminal will appear to have failed when it is not faulty. It is therefore important to make sure all test are performed correctly. The sections below describe the procedure for functional tests. The sections below describe each of the functional tests. 5.1.1 LCD Test Three test screens will be displayed, each for 2 seconds. The first test screen is a chequerboard and the second is an inverted version of the first test screen. The operator has to look for a stuck pixel or any abnormalities in the display. The third screen is a confirmation screen to which the operator has to press ENTER() if the display is working correctly or CANCEL(X) otherwise. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 15 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 5.1.2 LED Test Each Contactless LED blinks in turn and the operator has to acknowledge this by pressing the ENTER() key if the LED is blinking correctly or CANCEL(X) otherwise. After the Contactless LED test, the Function Key LED will blink, and the operator has to acknowledge this in the same way. 5.1.3 Keypad Test The terminal requires the operator to press each of the keys on the Keypad. The terminal will indicate which key should be pressed and then moves to the next key if the press was successfully registered, until all keys have been tested. 5.1.4 Mag-Swipe Test The operator should swipe the test card provided. The terminal, on reading the swipe card, will record the success or failure. The operator is allowed a second try if the first swipe was not done properly. 5.1.5 Chip card Test The terminal will request the operator to insert the test card provided into the chip card slot. The terminal will read the card and record the result. The terminal will then request the operator to remove the card to proceed to the next test. 5.1.6 Contactless card Test The operator has to bring a contactless card near the contactless logo when prompted. The terminal will read the card and record the success or failure accordingly. 5.1.7 Charger Test The terminal will request the operator to insert the USB cable connected to PC or USB wall adapter and check for Red charging LED next to the USB connector, if ON press ENTER() otherwise CANCEL(X). The terminal will then request the operator to remove the USB and check if the Red LED is off, if OFF press ENTER(). 5.1.8 Charging Cradle Test This will test that the charging contacts for use with a Fast Charge Cradle or Fast Charge Rack are working correctly. The contacts to be tested are 5V fast charge and GND, as shown in item 2 in the M010 Features section. The terminal will request the operator to place the terminal in the Fast Charge Cradle, which in turn is powered by a 5V 2A power supply. NOTE: The polarity of the charging contacts should be carefully noted. Applying the wrong voltage to these contacts will damage the unit. After a short period the terminal will then request the operator to remove it from the charging cradle, which removes power from the charging contacts. The operator will be notified if the test fails. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 16 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 5.1.9 Bluetooth Test The operator should have the provided Bluetooth responder powered on and in Bluetooth range for this test. This test is automated and does not require any other input from the operator. The result will be recorded accordingly by the terminal and the operator will be notified if the test fails. 5.1.10 This is an automated test. The operator will be notified if the test fails. Apple Co-Processor Test Hardware Functionality Test Completion 5.1.11 Once all the tests have been executed, the test results will be exported in the MSD. The terminal will indicate on the display that the results have been exported in MSD. The results can be retrieved and attached to any reports as needed. The terminal can then be powered off. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 17 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 6 End-user Troubleshooting It is not possible for Miura to define end-user troubleshooting, as there are many components in the end-user experience which are not defined or controlled by Miura. It is envisaged that the partner will define the troubleshooting process, in part using information from this document. This section gives some suggestions about what should be included as part of this process. Note that problems reported as the terminal not responding may in fact be caused by an issue with the smart device or the application running on it. Does the device power on?
If the terminal does not power on, it should be charged for at least 3 hours (refer to Charging the battery). The red charging LED can be used as an indication that the terminal is charging correctly. If the terminal still will not power on, the power source and USB cable being used should be verified. Does the terminal perform as expected?
If the terminal displays System Tampered it should be returned for investigation If the terminal does not perform as expected, and the issue is believed to be with the terminal as opposed to the smart device, then the user should Reboot the terminal using the ReviveTM feature. If the terminal is still not functioning as expected, and everything possible has been done to rule out the smart device and application, a System Restore should be performed. If the terminal is still not functioning as expected, a Total Factory Reset should be performed. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 18 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 7 Filtering Process This section is aimed at determining if a given terminal is functioning correctly and is acceptable for use in the field. It is not envisaged that this process will be carried out by the end-user, but will form the basis of testing performed by Miura and the partner at various stages in the terminal's life cycle including: Miura OBA (Out of Box Audit), Partner QA Testing, Partner returns filtering and Miura returns filtering. Each of these stages will no doubt include other additional tests and processes as defined by the organisation performing the stage (and documented separately) but the filtering process defined in this section should be common to all. Equipment required is as detailed in Functional Test plus the following:
Adequate light source Magnifying glass 1A USB mains adaptor and USB cable (enough to charge all units before-filtering) Inspection gloves (to avoid leaving fingerprints on new units) Step1: Perform a visual inspection on the terminal (to check for imperfections, damage, rattles etc) If this passes go to step 2. If this fails the damage should be photographed and recorded. Step 2: Charge the terminal and Power it on. Charge each terminal for at least 1 hour using a 1A USB mains adaptor and USB cable. Take the terminal off charge and switch it on (if it is not on already) If the terminal powers on, go to step 3. If the terminal will not power on, it is faulty. Step 3: Check the terminal starts up. If the terminal starts up normally (see Operating the M010 Terminal), go to step 4. If the terminal displays system tampered, the terminal is faulty. If the terminal is in any other state, record the error state, obtain and store the terminal diagnostics files and attempt to recover the terminal by performing a factory reset. If the terminal now starts normally, go to step 4. If not, the terminal is faulty. Step 4: Run the Terminal Diagnostics and Functional Test. Run the terminal diagnostics and functional test. Retain all the log files created during these processes If the terminal passes all functional tests, the terminal is deemed no fault found. If the terminal fails any of the tests, it is faulty. All retrieved diagnostic files should be retained as they will be needed in any diagnostics which may be carried out. NOTE: The terminal will also report a failure after a Factory Test if the tests are carried out incorrectly, or if any test is skipped, in which case the test needs to be repeated in full. If a particular test fails, the operator can choose to continue with the remaining tests M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 19 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 8 Appendix A: Example Diagnostic Files 010-000110-Conf.txt This file identifies the hardware and software configuration of the Terminal. Customer=Generic Sound=N/A GSM=N/A Charge_cradle=5V Smartcard=TDA8029HN Flash=NAND 2kblocks*64pages*2112bytes*8b USB_WiFi=N/A RAM=LPDDR 4Banks*8Mwords*16b Contactless=M010-EMVPCDHW-V1 Hardware=M010-TEST01-V2-0 Series=Shuttle USB_Bluetooth=LM506-0516 Backlight=N/A Serial=010-000050 Power=LP3910 OS=M000-DEVOS-V7-2 Ethernet=N/A Printer=N/A Light_sense=N/A Battery_Low=N/A Mag_sense=N/A Battery_Stats=N/A USB_OTG=500mA Display=Mono 128*64 SSD1309 Processor=MCIMX258CJM4A Keyboard=3x5(NA,M010,CLR,1,2,3,4,5,6,7,8,9,CNL,0,ENT)+Pwr+Revive KB_backlight=N/A MFi=MFI337S3959 LEDs=M010 PCBA=M010-PCBA01A-V1-5 Mag=3-Track MRD532 010-000110-Info.txt This file provides information about the Terminal, including: hardware part number, current OS part number, Serial Number, current application part number and finger print of the Remote Key Injection CA certificate loaded in manufacture. Hardware : M010-PROD01-V2-0 Software : M000-OS-V7-4 Serial : 010-000050 App-version : M000-MPI-V1-28-CONF15-V1 M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 20 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 CA-fingerprint: 93:DD:63:E0:19:50:FE:15:FF:57:F7:59:C7:34:65:5A:0E:75:4C:F8 010-000110-Events.txt The File records the system events happened from the manufacture of the Terminal. Jun 18 11:32:41 miura miura-monitor: Couldn't access shutdown time data Jun 18 11:32:41 miura miura-monitor: Startup time - Wed Jun 12 11:32:08 2013 Jun 18 11:32:42 miura miura-monitor: Start-Up event - Wipe (4) Jun 18 11:32:44 miura factory-test: Starting terminal key verification Jun 18 11:32:44 miura factory-test: Terminal key verification success Jun 18 11:32:46 miura factory-test: Ready to install Application Jun 18 11:34:33 miura factory-test: Application installation starting Jun 18 11:34:56 miura miura-auth: Request for make_factory Jun 18 11:34:57 miura miura-auth: Request for make_restore Jun 18 11:34:57 miura factory-test: Application installation successful Jun 18 11:36:23 miura miura-monitor: Shutdown time - Wed Jun 12 11:35:01 2013 Jun 18 11:36:23 miura miura-monitor: Startup time - Wed Jun 12 11:35:57 2013 Jun 18 11:41:26 miura miura-monitor: Shutdown time - Wed Jun 12 11:35:01 2013 Jun 18 11:41:26 miura miura-monitor: Startup time - Wed Jun 12 11:41:00 2013 Jun 18 11:41:26 miura miura-monitor: Start-Up event - Start Terminal Diagnostics (7) 010-000110-Results.txt Summary of the functional tests.
********* LCD Test *********
LCD Test: SUCCESS
********* LED Test *********
Pinpad LED Test: SUCCESS
************* Keypad Test **************
Keypad Test: SUCCESS
*********** Mag-Swipe Test *************
Mag-swipe-test: TRK1 - PASS Mag-swipe-test: TRK2 - PASS Mag-swipe-test: TRK3 - PASS Mag Swipe Test: SUCCESS
*********** Smart-Card Test ************
Smart card Test: ATR Received: Size = 19. Smart card Test: ATR: 3b5f9500807300010059434c5a1b0011409000 Smart card Test: SUCCESS M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 21 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21
********* Contactless Card Test *********
Contactless: Card Detected!!!
Card in field Contactless card Test: SUCCESS
************* Charger Test *************
Charger Test: SUCCESS
************* Cradle Test *************
Cradle Test: SUCCESS
************ Bluetooth Test ************
Manufacturer: Broadcom Corporation (15) Firmware 0.34 / 14 HCI version: 4.0, LMP version: 4.0 Waiting for connection... accepted connection from 20:12:11:15:16:5D received [hello!]
Bluetooth Test: SUCCESS
************ Apple co-processor test ************
Apple co-processor test co-processor info:
Apple Co-Pro Test: SUCCESS Factory Test: Functionality tests completed. Device version 5 Firmware Version 1 Protocol Major version 2 Protocol minor version 0 Device ID 0x00000200 M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 22 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 9 Appendix B: Regulatory Information Battery: This product uses a Lithium-Ion battery. Do not use it in a humid, wet and/or corrosive environment. Do not put, store or leave your product in or near a heat source, in a high temperature location, in strong direct sunlight, in a microwave oven or in a pressurised container, and do not expose it to temperatures over 60C (140F). Failure to follow these guidelines may cause the battery to leak, become hot, explode or ignite and cause injury and/or damage. Do not pierce, open or disassemble the battery. If the battery leaks and you come into contact with the leaked fluids, rinse thoroughly with water and seek medical attention immediately. For safety reasons, and to prolong the lifetime of the battery, when not in use store your product in a cool, dry place. Charging will not occur at low (below 0C/32F) or high (over 45C/113F) temperatures. Caution: Do not remove or attempt to remove the non-user-replaceable battery. THE BATTERY CONTAINED IN THE PRODUCT MUST BE RECYCLED OR DISPOSED OF PROPERLY ACCORDING TO THE LOCAL LAWS AND REGULATIONS AND ALWAYS KEPT SEPARATE FROM HOUSEHOLD WASTE. BY DOING THIS YOU WILL HELP CONSERVE THE ENVIRONMENT. CE marking This equipment complies with the requirements for CE marking when used in a residential, commercial, or light industrial environment, achieving all the appropriate provisions of the relevant legislation in the EU. RED directive Hereby, Miura Systems Ltd declares that Miura Systems Ltd products and accessories are in compliance with the essential requirements and other relevant provisions of the EU Directive 2014/53/EU. The declaration of conformity can be found on the Miura Partner Portal at www.miurasystems.com WEEE directive The wheelie bin symbol on the product or its packaging indicates that this product shall not be treated as household waste. In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling. By doing this you will help conserve the environment. Pacemakers Pacemaker manufacturers recommend that a minimum of 15cm (6 inches) be maintained between a handheld wireless device and a pacemaker to avoid potential interference with the pacemaker. These recommendations are consistent with independent research and recommendations by Wireless Technology Research. Guidelines for people with pacemakers You should ALWAYS keep the device more than 15cm (6 inches) from your pacemaker. You should not carry the device in a breast pocket. Other medical devices Please consult your physician or the manufacturer of the medical device, to determine if the operation of your wireless product may interfere with the medical device. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 23 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement The Miura M010 has been designed and complies with the safety requirements for portable RF exposure in accordance with FCC rule part 2.1093 and KDB 447498 D01. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 24 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21 Canada ISED This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil contient des metteurs / rcepteurs exempts de licence qui sont conformes au (x) RSS (s) exempts de licence d'Innovation, Sciences et Dveloppement conomique Canada. L'opration est soumise aux deux conditions suivantes:
(1) Lappareil ne doit pas produire de brouillage.
(2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Radiation Exposure Statement The Miura M010 complies with the safety requirements for RF exposure in accordance with RSS-102 Issue 5 for Portable Limb-worn / Extremity Use conditions. Dclaration d'exposition aux radiations Le Miura M010 est conforme aux exigences de scurit relatives l'exposition aux radiofrquences, conformment la norme RSS-102, dition 5, pour les conditions d'utilisation des membres ports sur les membres et des extrmits. M010-GUIDE01-V1-3 Confidential Miura Systems 2019 Page 25 of 25 Registered office: Miura Systems Ltd, Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ Company no: 06714257 Vat reg: 940 6618 21
1 2 | Agent Authorization Rev 1.0 | Cover Letter(s) | 21.06 KiB | January 13 2020 |
Miura Systems Ltd Agent Authorization Company: Miura Systems Ltd Address: Unit 3, Cliveden Office Village, Lancaster Road, Cressex Industrial Estate, High Wycombe HP12 3YZ, United Kingdom Product Name: Portable payment terminal Model Number(s): M010 Product Description: Portable payment terminal We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:
Date: 2020-01-08 Name:
Gareth Richards Title:
Chief Technical Officer Company: Miura Systems Ltd
1 2 | FCC Short & Long Term Confidentiality | Cover Letter(s) | 96.06 KiB | January 13 2020 |
Miura Systems Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2020/01/08 Subject; Request for Confidentiality FCC ID: 2AO4FM010-3 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name: Gareth Richards Title: Chief Technical Officer
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-01-13 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
2 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2020-01-13
|
||||
1 2 | Applicant's complete, legal business name |
Miura Systems Ltd
|
||||
1 2 | FCC Registration Number (FRN) |
0024099434
|
||||
1 2 | Physical Address |
Unit 3, Cliveden Office Village, Lancaster Road Cressex Industrial Estate
|
||||
1 2 |
Unit 3, Cliveden Office Village, Lancaster Road
|
|||||
1 2 |
High Wycombe, N/A
|
|||||
1 2 |
United Kingdom
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
2AO4F
|
||||
1 2 | Equipment Product Code |
M010-3
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
R**** S********
|
||||
1 2 | Title |
Senior Engineer
|
||||
1 2 | Telephone Number |
01494********
|
||||
1 2 | Fax Number |
01494********
|
||||
1 2 |
r******@miurasystems.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
Miura Systems Ltd
|
||||
1 2 | Physical Address |
United Kingdom
|
||||
1 2 |
g******@miurasystems.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 2 | DXX - Part 15 Low Power Communication Device Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Portable payment terminal | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Output power listed is conducted power. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Dongguan NTC CO., Ltd.
|
||||
1 2 | Name |
J**** H******
|
||||
1 2 | Telephone Number |
+86-7********
|
||||
1 2 |
j******@ntc-c.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0040900 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC