CONTENTS SECURE PLUG (PATENT PENDING) USER GUIDE Product Manual for SECURE PLUG Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Materials in Box Installation Key Whitelist Merchandising Arming & Disarming the System Remerchandising Adding New User Keys Deleting Whitelist LED Status Indicators FCC and ISED Statement 2 3 4 5 7 8 8 8 9 12 DO NOT REMOVE FROM STORE For additional support, please reach out to our Contact Center at 800-426-6844 www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 1 MATERIALS IN BOX SECURE PLUG (PATENT PENDING) USER GUIDE Secure Plug Power Strip (Region-Specic) Alarm Label Sheet Remote Access Module (Optional) www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 2 INSTALLATION SECURE PLUG (PATENT PENDING) USER GUIDE WARNING: No user serviceable parts inside. Please contact MTI for service. CAUTION: To Reduce the Risk of Electric Shock Use Only Indoors. CAUTION: Risk of Electric Shock. Do not plug into another relocatable power tap or an extension cord. CAUTION: Use Only in Dry Locations. AVERTISSEMENT: Aucune pice rparable par lutilisateur lintrieur. Veuillez contacter MTI pour le service. ATTENTION: Pour rduire le risque de choc lectrique - Utiliser uniquement lintrieur. ATTENTION: Risque de choc lectrique. Ne pas brancher sur une autre alimentation ou une rallonge. ATTENTION: Utiliser uniquement dans des endroits secs. 1 FOR SCREW MOUNT (OPTIONAL): Use three #6 wood screws (not included). Measure and install screws into mounting surface leaving 1/4 of the screw heads exposed. Align the Power Strip keyholes (circled in blue) and hang onto the screws. 1.6 in
(42 mm) 2.4 in
(62 mm) 2 IF USING THE REMOTE ACCESS MODULE: Plug in to the end of the Power Strip and afx to surface, if desired. 3 Plug Power Strip into a wall outlet. 7.9 in
(200 mm) The Remote Access Module allows you to use the RFID cards to control the Secure Plug when access to the unit is difcult. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 3 KEY WHITELIST 1 Place Authorization Card over the RFID icon to register to system. LED will be solid blue. SECURE PLUG (PATENT PENDING) USER GUIDE 2 Place the User Key over the RFID icon you want to add. If successful unit beeps 2 times If unsuccessful unit beeps 4 times (retry) Repeat process for all User Keys until they are successfully added. The whitelist process can be done on the Secure Plug unit or through the Remote Access Module. 3 To close the whitelist mode, place the Authorization Card over the RFID icon. Whitelist mode will end automatically after 3 minutes of no use. LED will be ashing white. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 4 MERCHANDISING 1 SECURE PLUG (PATENT PENDING) USER GUIDE Unplug any cables from the product end for products that have removable power cords. If the product does not have a removable power cord, turn the power to the product to OFF. 9 8 NOTE: Only supports products up to 10A. 2 Plug in product cables one at a time to the Power Strip. If successful 2 beeps and LED will be solid green, this may take 20 to 60 seconds for products with larger power adapters. The Remote Access Module will show a corresponding white LED for that socket port. If unsuccessful unit beeps 4 times and LED will be solid red. The Remote Access Module will show a corresponding red LED for that socket port. Unplug cable from the Power Strip and try again making sure cables are unplugged from the product. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 5 MERCHANDISING 3 Repeat steps with next product to merchandise. SECURE PLUG (PATENT PENDING) USER GUIDE 4 When all products have been successfully setup, plug cables back into product end at this time. Apply an Alarm label to product end of cable, if desired. 5 Turn the power to products with a detachable power adapter to ON at this time. Keep power to other products OFF (ie. hardwired products or products without power adapters). www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 6 ARMING/DISARMING THE SYSTEM 1 Place any User Key over the RFID icon and the LED will change from ashing white to solid white to indicate Armed. SECURE PLUG (PATENT PENDING) USER GUIDE 2 Turn the power to products to ON or OFF at this time, as desired. 3 If any cable becomes unplugged, the system will alarm. LED will ash red/white. The Remote Access Module will show a corresponding red LED for that socket port. 4 Placing a User Key over the RFID icon will silence the alarm. The LED will remain ashing red/white. 5 To re-arm, x the issue by plugging all cables back in. Place a User Key over the RFID icon and the LED will be solid white. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 7 REMERCHANDISING 1a From an Armed state, place the User Key over the RFID icon to disarm the system. LED will be ashing white. SECURE PLUG (PATENT PENDING) USER GUIDE 1b From an Alarming state, place the User Key over the RFID icon to silence the alarm. Then hold down the User Key for 5 seconds to return back to the disarmed state. LED will be ashing white. 2 Merchandise a new product by following the process on page 5. If you did not unplug a product, there is no need to remerchandise the product again. ADDING NEW USER KEYS 1 From an Armed state, place the User Key over the RFID icon to disarm the system. LED will be ashing white. 2 Place Authorization Card over the RFID icon. Follow Key Whitelist process starting on page 4. From an Armed state, place the User Key over the RFID icon to disarm the system. LED will be ashing white. DELETING WHITELIST (This will delete all User Keys from the system.) 1 Place the Authorization Card over the RFID icon AGAIN while LED is yellow. If successful unit beeps 2 times and the LED will turn solid green If unsuccessful unit beeps 4 times (retry) Hold down the Authorization Card for 5 seconds, LED will be solid yellow. 2 3 www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 8 LED STATUS INDICATORS SECURE PLUG (PATENT PENDING) USER GUIDE Visual Reference System Status Condition Solution LED is solid white. Armed System is armed. LED is ashing white. 1. Disarmed 2. Merchandising Calibration 1. System is disarmed and needs to be re-
armed. 2. System is calibrating product, wait until successful or unsuccessful merchandising before proceeding. LED is ashing red and white. Alarm System is alarming and needs to be attended to. LED is ashing red. Mains Power Loss Mains power loss has occurred. System will alarm for 5 minutes. Whitelist and merchandising information will be maintained upon restoration of power. LED is solid red. Merchandising Unsuccessful If merchandising fails, unplug the product. Follow merchandising process again. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 9 LED STATUS INDICATORS SECURE PLUG (PATENT PENDING) USER GUIDE Visual Reference System Status Condition Solution LED is solid green. Ready to Whitelist System has an Authorization Card, but does not have any User Keys added. Follow key whitelist process. LED is ashing green. Factory Reset System has no whitelist or Authorization Card. Follow key whitelist process. LED is solid blue. 1. Whitelist Mode (if using Authorization Card) 2. Overcurrent 1. System is in whitelist enrollment mode. Follow whitelist process to add User Keys. 2. System has gone into overcurrent protection. Unplug any product which may be drawing too much power. LED is ashing blue. Overcurrent/Disarmed System has gone into overcurrent protection and user has disarmed the system. Unplug any product which may be drawing too much power. The system will self-heal. LED is ashing yellow. 1. Ready to be Armed without MTI Connect Mesh Connected 2. Merchandising Calibration without MTI Connect Mesh Connected 1. Add Secure Plug unit to Mesh network. 2. System is calibrating product, wait until successful or unsuccessful merchandising before proceeding. LED is solid yellow. 1. Armed without MTI Connect 1. Add Secure Plug unit to Mesh Connected Mesh network. 2. Delete Whitelist Mode (If using 2. System is deleting whitelist. Wait until Authorization Card) complete. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 10 LED STATUS INDICATORS SECURE PLUG (PATENT PENDING) USER GUIDE Visual Reference System Status Condition Solution Individual LED is solid white
(not main LED) Merchandising successful for that socket port See main LED for overall system status. Individual LED is solid red
(not main LED) 1. Merchandising unsuccessful for that socket port 2. Alarm 1. If merchandising fails, unplug the product. Follow merchandising process again. 2. System is alarming on corresponding socket port and needs to be attended to. See main LED for overall system status LED is ashing blue. 1. Provisioning Mode 2. Overcurrent/Disarmed 1. System has entered Mesh network provisioning mode. If its within range of a Hub that is also in provisioning mode, it will join the Hubs network within 5 seconds and it will stop ashing blue. 2. System has gone into overcurrent protection and user has disarmed the system. Unplug any product which may be drawing too much power. The system will self-heal. LED is ashing multiple colors. System has received an identify command from a user of the MTI Connect software. www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 11 FCC AND ISED STATEMENT SECURE PLUG (PATENT PENDING) USER GUIDE FCC ID: 2AA2X-165-471 Model: 165-00471 FCC Statement FCC ID: 2AA2X-165-645-24 Model: 165-00645 / 165-00670 FCC Statement This device complies with Part 15 of the FCC Rules. Caution: If any changes or modications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The grantee is not responsible for any changes or modications not expressly approved by the party responsible for compliance. Such modications could void the users authority to operate the equipment. The RF Exposure Compliance distance is 20 millimeters. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ISED Certifcation Number: 24439-165471 Model: 165-00471 ISED Statement ISED Certifcation Number: 24439-16564524 Model: 165-00645 / 165-00670 ISED Statement This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. CAN ICES-3(B)/NMB-3(B) Le prsent appareil est conforme aux CNR Innovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(1) il ne doit pas produire de brouillage et (2) l utilisateur du dispositif doit tre prt accepter tout brouillage radiolectrique reu, mme si ce brouillage est susceptible de compromettre le fomctionnement du dispositif. CAN ICES-3(B)/NMB-3(B) The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. Le dispositif rencontre lexemption des limites courantes dvaluation dans la section 2.5 de RSS 102 et la conformit lexposition de RSS-102 rf, utilisateurs peut obtenir linformation canadienne sur lexposition et la conformit de rf. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 millimeters between the radiator and your body. Cet metteur ne doit pas tre Co-plac ou ne fonctionnant en mme temps quaucune autre antenne ou metteur. Cet quipement devrait tre install et actionn avec une distance minimum de 20 millimtres entre le radiateur et votre corps. Technical Data Model: 165-00471 Operating Frequency:
Operating Temperature:
Max Power:
Technical Data Model: 165-00645 / 165-00670 125KHz 0 C to 40 C 125KHz: <42dBuA/m at 10m Operating Frequency:
Operating Temperature:
Max Power:
125KHz, 2.4GHz: 2405-2480MHz 0 C to 40 C 125KHz: <42dBuA/m at 10m 2.4GHz: <20dBm MTI declares that the radio equipment models 165-00460, 165-00470 and 165-00471 Secure Plug Power distribution units including the models 165-00645 and 165-00670 Remote Access Modules in compliance with EU Directive 2014/53/EU. The full text of the EU Manufacturers Declaration of Conformity is available at the following internet address: www.mobiletechinc.com Mobile Technologies Inc. - 1050 NE 67th Ave, Hillsboro, OR 97124 www.mobiletechinc.com | T:800.426.6844 MTI P/N 063-00243 rev B 2018 MTI All Rights Reserved 12