submitted | available | document details (if available) | source link |
---|---|---|---|
Adobe PDF Library 15.0 |
various | Manual | Users Manual | 3.47 MiB |
Lumen iL33 ASSY T325R RF IR PR 1x | ASSY T325R RF 4x | insullation ring 2x | filter 2x | connector RJ45 Warning This equipment should be installed, operated, serviced, and repaired by qualified personnel only. The installation and interconnection of this equipment to facility wiring and other equipment must be done by a competent, qualified craftsperson who is familiar with applicable standards and codes governing the installation. Installation methods, practices, or procedures that are unauthorised or done improperly are dangerous and could result in serious personal injury or damage to property and equipment. dimensions 325mm 1'0.80"
20mm 0.79in 277,5mm 10.93in Mounting holes Use M10-studs
"
1 4 0 5
'
. m m 3 4 3 5 1 i n 6 3 2
. m m 0 6
) r e t n u o c r e m o t s u C
(
"
6 2 6 4
'
. m m 3 8 7 3 1 i n 2 1 9
. m m 7 1 3 2
. 322mm 1'0.68"
328.6mm 1'0.94"
97.7mm 3.85in conduit or slit
(topview) Quick reference : ASSY T325R RF IR PR N.V. Nederlandsche Apparatenfabriek Nedap Parallelweg 2, NL-7141 DC Groenlo (The Netherlands) Mail: support-retail@nedap.com dsgn date item
: CvdB
: 28 March 2018 1:31 PM
: 9224386 Copyright by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP. document revision
: T9224386-45.01
: A.01 1 drill the hole 13 mm ( 0.5in) 13mm / 0.5 1
. i
) n 5 5 3 3
/
(
m m m m 0 9 0 9 1 2 3 4 Drill the hole Clean the hole Insert Hilti-hit Place the nut always use a nylon insulation ring 2 1 3 4 2 2 3 1 2 3 Nut M10 Retainer ring M10 Nylon insulation ring M10
(not included in installation set)
(not included in installation set)
(included in installation set) remove covers 1 1 1 Screw M3x10 2 installation orientation The arrow indicates the direction to the store exit. place near to a wallsocket (RF) Power Inserter (P.I.) always on the right side. distance to the wall (RF) distance to a normal door or sliding door (RF)
> 20 cm (7.9in)
> 20 cm (7.9 in.)
> 40 cm (15.8in)
> 40 cm (15.8 in.) 3 distance to roller shutter (RF)
> 70 cm (27.6in)
> 70 cm (27.6 in.) cabling 1 2 Ethernet cable Renos side filters 2 2 1 1 2 3 Filter Renos network IN Renos network OUT power system Plug the Power Inserter into the socket. 1 3 2 P.I. > network OUT 1 1 230V 115V NOTE:
Start up takes approximately 3 minutes. INPORTANT:
Network should be connected in the network setup-step of the installation wizard. Do not connect a network to !Sense before power up!
4 connecting a laptop to the Renos unit Renos - Service port Attach your laptop to one of the Renos units with a mini USB-USB cable. Open the browser on your laptop and go to:
http://192.168.133.1 Configure the system using the installation wizard. place keyswitch
(optional) 3 1 2 3 Remove cover Push to remove small metal part Place keyswitch (can be placed on both sides of the antenna) 1 2 place covers 1 Screw M3x10 1 1 5 label information 1 1 Pull to see the label information (Two labels at the front side and one at the back side) network setup When on the network setup -step of the installation wizard, determine the position of the network and decide how to connect to the !Sense network. 1 2 3 1 2 3 Network to Power Inserter IN Network to last Renos OUT Network to USB-Network adapter (in any gate) Renos 1 2 3 4 5 6 7 8 9 50 Lights / IR Add-on Network IN USB Network OUT Mini USB service port RS485 connector Buzzer connector 1 Connect to the 50 PCB from the antenna. Connect to the lights and customer counting. Provide power and synchronisation to add-ons, like the RFID reader. Connected to the Network OUT of a previous Renos unit or a Power Inserter. Connect accessories to Renos, like the RFID reader or USB network adapter. Connected to the Network IN of a previous Renos unit or a Power Inserter. Can also be left unconnected or connected to the customer network. Connect your laptop to configure the Renos system. Connect to the smart deactivator(s). Connect to the buzzer. 2 3 4 5 6 7 8 9 Caution:
Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. status LEDs Renos 1 2 3 4 5 6 Green Blue Red Yellow Green Green On Off Blinking On On Blinking Off Blinking Off Blinking Off On Off 4 5 6 1 3 2 1 There is a Renos unit connected to the OUT port of this unit There is no Renos unit connected to the OUT port of this unit There is no device connected to the OUT port of this unit There is a Power Inserter connected to the OUT port of this unit There is an issue with the power supply at the OUT port of this unit (too little current drawn) There is an issue with the power supply at the OUT port of this unit (too much current drawn) There is no issue with the power supply at the OUT port of this unit The operating system on the Renos unit is running The operating system on the Renos unit is not running The storage flash on the Renos unit is accessed The storage flash on the Renos unit is not accessed The firmware on the Renos unit is running The firmware on the Renos unit is not (yet) running 6 Disclaimer Nedap intends to make this manual accurate and complete. However, Nedap does not warrant that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. Nedap disclaims any liability for damage to property or personal injury resulting, in whole or in part, from improper installation, modification, use or misuse of its products. The information contained in this document is subject to change without notice. FCC and IC Compliance statement This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Cet appareil se conforme aux normes CNR 210 exempts de license du Industry Canada. Lopration est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interfrence, et
(2) cet appareil doit accepter nimporte quelle interfrence, y inclus interfrence qui peut causer une opration non pas voulu de cet appareil. Les changements ou modifications nayant pas t expressment approuvs par la partie responsable de la conformit peuvent faire perdre lutilisateur lautorisation de faire fonctionner le matriel. FCC and IC Radiation Exposure Statement This equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 5cm between the radiator and a human body for normal operation. Personel standing permanently next to the antenna frame must keep a distance of at least 30cm. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme a CNR-102 limites nonces pour un environne- ment non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 5 cm entre le radiateur et un corps humain pour un fonctionnement normal. Les personnes se tenant en permanence ct du cadre de lantenne doivent respecter une distance minimale de 30 cm.This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numrique de Classe B est con-
forme la norme Canadienne ICES-003. FCC Information to the user Note: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver. NOTE: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. To ensure compliance with FCC regulations, use only the shielded interface cables provided with the product, or additional specified components or accessories that can be used with the installation of the product. Declaration of Conformity Hereby, De N.V. Nederlandsche Apparatenfabriek Nedap declares that the radio equipment type ASSY T325R RF is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://portal.nedapretail.com/
User manual The complete instruction manual can be found at https://portal.nedapretail.com/
7 8
This product uses the FCC Data API but is not endorsed or certified by the FCC