submitted | available | document details (if available) | source link |
---|---|---|---|
various | User manual | Users Manual | 124.92 KiB |
FCC MANUAL XQMK2 Dynamic Line July 15, 2011 This information is furnished for guidance, and with no guarantee as to its accuracy or completeness;
Its publication conveys no license under patent or other right, nor does the publisher assume Liability for any consequence of its use; specifications and availability of goods mentioned in it are Subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher. N.V. Nederlandsche Apparatenfabriek Nedap Part#: 9948473 Page 1 of 9 Technical Support E-Mail info-rs@nedap.com Postal address N.V. Nederlandsche Apparatenfabriek Nedap, Parallelweg 2, 7141 DC, Groenlo, The Netherlands Phone
+31 (0) 544-47 11 11 Fax
+31 (0) 544-46 34 75 Safety precautions CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED NEDAP SERVICE PERSONNEL. Lightning flash with an arrowhead, enclosed in a triangle, alerts you to the presence of uninsulated voltage points inside the product which could cause a serious electrical shock. An exclamation mark enclosed in a triangle alerts you to important operating and maintenance instructions in the documentation provided with the product. WARNING! To avoid the risk of fire or electrical shock, never expose these products to water or operate in a high humidity environment. This European Standard specifies a marking
of electrical and electronic equipment in accordance with Article 11(2) of Directive 2002/96/EC
(WEEE); This is in addition to the marking requirement in Article 10(3) of this Directive which requires producers to mark electrical and electronic equipment put on the market after 13 August 2005 with a crossed-out wheeled bin symbol. that applies to electrical and electronic equipment falling under Annex IA of Directive
2002/96/EC, provided the equipment concerned is not part of another type of equipment that does not fall within the scope of this Directive. Annex IB of Directive 2002/96/EC contains an indicative list of the products, which fall under the categories set out in Annex IA of this Directive;
that serves to clearly identify the producer of the equipment and that the equipment has been put on the market after 13 August 2005. EN 50419:2005 2010 N.V. Nederlandsche Apparatenfabriek Nedap Parallelweg 2 NL-7141 DC Groenlo The software / hardware described in this book / file is furnished under a license agreement and may be used only in accordance with the terms of the agreement. Copyright Notice All Rights Reserved. Any technical documentation that is made available by N.V. Nederlandsche Apparatenfabriek Nedap is the copyrighted work of N.V. Nederlandsche Apparatenfabriek Nedap and is owned by N.V. Nederlandsche Apparatenfabriek Nedap. Page 2 of 9 No warranty The technical documentation is being delivered to you and Nedap makes no warranty as to its accuracy or use. Any use of the technical documentation or the information contained therein is at the risk of the user. Documentation may include technical or other inaccuracies or typographical errors Nedap the right to make changes without prior notice. No part of this publication may be copied without the express written permission of N.V. Nederlandsche Apparatenfabriek Nedap Parallelweg 2, NL-7141 DC Groenlo, Netherlands Trademarks Nedap, the Nedap logo, Nedap EASi/Net and the Nedap EASi/Net are registered trademarks of N.V. Nederlandsche Apparatenfabriek Nedap. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Printed in the Netherlands Notice The documentation is based in a Part numbers and Drawing number structure. Part number can also be named as Artikel nummer or Article number Drawing numbers can also be named as: Tekening Drawing numbers are build up in a the drawing Number with a structure Txxxx-yyy-zz Txxxx-yyy is the drawing number and extension number zz means:
10 11 12 Xxxx yyy is an overview drawing of the part and can contain wiring and circuit diagrams;
is the bill of material;
is the circuit diagram of the device.
= 0000 9999
= 000-999 Page 3 of 9 Table of content 1. 2. 3. 4. 5. Introduction System overview Wiring diagram FCC Declarations Specifications XQMK2 5 6 7 8 9 Page 4 of 9 INTRODUCTION 1 N.V. Nederlandsche Apparatenfabriek Nedap further on called Nedap manufactures reliable and scalable EAS Systems. With this XQ system your able to reduce the shoplifting costs the best in combination with Nedaps tag line. The XQMK2 system produces an acoustic - and visual signal when it detects an operating tag by means of the antennas and will identify a visitor with the active tag on one of his carried items. XQMK2 is developed for middle scaled configurations. It starts with 2 antennas for one entrance scalable up to 150 entrances. The system is buildup in four different types of components:
Antennas with the following types: PG27, PG39, FL30 and FL45;
Transmitter and Receiver units installed into the antennas;
Network controller unit named NCC;
Power inserter. With The Dynamic line XQMK2 youre able to build big EAS systems connectable to the EASi/Net or Cube system. Some of the advantages are:
1. On the antenna there is an additional advertising space;
2. The antenna color can be chosen for a fitting look in the shop;
3. There is the opportunity to integrate the customer counting feature to measure the visitor stream;
4. Optional is the communication of the system to the outside world via GSM/GPRS, PSTN, LAN or WiFi. 5. The system is equipped with integrated metal detection functionality. Further details can be found in the XQ MK2 Installation Manual Page 5 of 9 2 System overview Figure 1 Functional system overview The XQMK2 system consists of the following components:
1. XQMK2 Tx Unit 2. XQMK2 Rx Unit 3. NCC unit for communication 4. Power inserter 5. Antenna frame 27 cm Model: PG27 6. Antenna frame 39 cm Model: PG39 7. Antenna frame 30 cm Model: FL30 8. Antenna frame 45 cm Model: FL45 9. Customer Counting unit including Lighting 10. Customer counting unit Rx 11. Customer counting unit RxTx 12. Customer counting unit Tx 13. Optional communication units:
a. PSTN: MT5600SMI-92 by Multitech CE approved, Canada IC: 125 11142A and USA FCC complies with 47 CFR Part 68: AU7USA-46014-MD-E or any other CE, FCC and IC approved PSTN. b. GSM/GPRS: MTSMCG-F4 by Multitech CE approved, Canada IC: 125A-0027 and USA FCC ID:
AU79U07A31817 or any other approved FCC or IC approved GSM c. LAN: XPORT by Lantronix d. WiFi: IEEE 802.11b WiPort 485 by Lantronix FCC ID: R68WIPORTG IC-ID:3867A-WIPORTG The XQMK2 system is complete wired up and ready for use. You only have to follow up the next steps. Install the XQMK2 system according the: XQMK2 installation guide lines;
o o Power up the XQMK2 system;
o Check the functionality;
o Call Nedap Customer Support for quick hands-on problem solution in case of unforeseen problems
[see Technical Support];
o Distance between two antennas when using hard tags 50 mm and FL30 antennas is: 2.2 m;
o Distance between two antennas when using paper tags 4x4 and FL30 antennas is:
1.7 m;
o Distance between two antennas when using hard tags 50 mm and FL45 antennas is: 2.45 m;
o Distance between two antennas when using paper tags 4x4 and FL45 antennas is:
2.0 m;
o Distance between two antennas when using hard tags 50 mm and PG27 antennas is: 2.30m;
o Distance between two antennas when using paper tags 4x4 and PG27 antennas is:
1.80 m;
Page 6 of 9 o Distance between two antennas when using hard tags 50 mm and PG39 antennas is: 2.60 m;
o Distance between two antennas when using paper tags 4x4 and PG39 antennas is:
2.20 m;
o Distance between an antenna and a wall, door, sliding door etc. must be at least 200 mm;
o Distance between an antenna and the nearest tagged item must be at least 2000 mm. 3 Wiring diagram Schematically diagrams below shows an example of the connections between used modules. The picture shows the full configuration that can be built up. t n A
. t n A
. t n A
. t n A
. t n A Figure 2 Example full configuration The connections for a full configuration are:
1. Datacom cable for NCC to Unit XQMK2 Connects Data communication and power from NCC [9203508] to a Unit XQMK2 Tx [8018464] or Unit XQMK2 Rx [8018472]. NOTE: The distance between the NCC and the transmitter antenna shall 4 meters or more. 2. Datacom cable for NCC to Unit XQMK2 Connects the data and power between the XQMK2 Tx or Rx Units. 3. Tx or Rx coax cable Connects the antenna input/output XQMK2 Tx [8018464] or Rx [8018472] to the EAS antenna loops PG27, PG39, FL30, FL45. 4. Rx or Tx cable for Metal detection Connects the metal detection antenna input/output from XQMK2 Tx [8018464] or Rx [8018472] to the Metal detection antenna loop PG27, PG39, FL30, FL45. 5. Cable for Customer counting and lighting unit PG27/PG39 Connects the XQMK2 Tx [8018464] or Rx [8018472]to the Customer Counter and lighting unit [7833342]. 6. Cable for Cusomer counting and lighting unit FL30/FL45 Connects the XQMK2 Tx [8018464] or Rx [8018472] to one of the Customer counter units [9923373, 9928529, 9936114, 9935207]. 7. Cable for lighting module FL30/FL45 Connects the XQMK2 Tx [8018464] or Rx [8018472] to the lighting module. 8. DC cable from Power adapter to NCC electronics Connects the Power-adapter [9651543] to the NCC main board [7824785] and carries 33V DC power. 9. Mains cable Connects the Mains power to the Power-adapter [9651543]. 10. Coax cable for GSM antenna Connects the GSM module to the GSM external antenna to contact the GSM network. 11. Datacom cables to slave NCCs Connects a NCC with the behavior Master to NCC devices with the behavior Slave. 12. Datacom cables for system expansion Connects more antenna strings up to 16 devices with the same function as Wire 1 and 2. Page 7 of 9 FCC Declarations 4 Complance statements (part15.19) This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil se conforme aux normes RSS210 exempts de license du Industry Canada. L'opration est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interfrence, et
(2) cet appareil doit accepter n'importe quelle interfrence, y inclus interfrence qui peut causer une opration non pas voulu de cet appareil. Warning (part15.21) Changes or modifications not expressly approved by party responsible for compliance could void the users authority to operate the equipment. This in particular is applicable for the antenna which can be delivered with the XQMKII System. RF Exposure (OET Bulletin 65) To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20cm separation distance between the antenna and all persons. Information to the User (Part 15.106(b)) Note: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which can be determine by turning the equipment off and on , the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Page 8 of 9 5 Specifications QXMK2. Enviromental Description Antenna Hight Antenna With Antenna Base Frame thickness Weight Material Construction Material Covers Protection Class Description EAS Operating frequency Metal Detection Operating Frequency Operational temperature Storage temperature PG27 PG39 FL30 FL45 1533mm 1670mm 1665mm 1665mm 273mm 104mm 20mm 13Kg PMMA 390mm 104mm 20mm 20Kg PMMA 322mm 100mm 70mm 12Kg 462mm 100mm 70mm 15Kg Aluminum Aluminum RVS Steel RVS Steel ABS HI-121, Calibre 201-15 Min. 7.4 MHz IP20 Typical Max. Condition 8.8 MHz 120 kHz 125 kHz 130 kHz 0C
-10C 40 C
+70C 90%
2.4m Relative Humidity Operating Distance Input Requirements and electrical specifications 20%
0.9m non-condensing Between antenna, Tag dependant Description Input Voltage Input Current Line Frequency Min. Typical Max. Condition 90VAC 264VAC Full Range; 50/60Hz
47 Hz 50-60Hz 2A 63Hz 60A 90VAC 50Hz
230VAC Cold Start Inrush Current @25C Operation Voltage 29.1VDC 30VDC 30.9VDC Power Regulations Safety approvals of the Power Adapter:
15W 20W 230VAC 50Hz cULus according to UL/CSA 60950-1 and UL1310 NEC Class 2 Japan PSE CE Europe according to EN60950-1 Telecom system approval Canada IC ID according to RSS210 IC ID: 1444A-XQMK2 US according to FCC Part 15 FCC ID: CGDXQMK2 CE according to EN 300 330 EN62369-1 and EN50364 ICNIRP Guidelines IEEE C95.1 RSS102 ARIB STD-38 In compliance with Human exposure assessment according to:
EN 301 489 IEC 61000-6-2 IEC 61000-6-3 CISPR 22 / EN55022 Electromagnetic compatibility Page 9 of 9
This product uses the FCC Data API but is not endorsed or certified by the FCC