7368 ISAM ONT BGW320-505 Product Guide 7368 Intelligent Services Access Manager ONT 7368 ISAM ONT BGW320-505 Product Guide 3FE-47753-AAAA-TCZZA Issue: 01 Nokia Proprietary and confidential Use pursuant to applicable agreements 7368 ISAM ONT BGW320-505 Product Guide Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners. The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein. 2019 Nokia. Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone outside Nokia without its written authorization. Not to be used or disclosed except in accordance with applicable agreements. 2 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Preface 1 Preface 1.1 Scope 1.2 Audience This preface provides general information about the documentation set for optical network terminals (ONTs). This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release. This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the ONTs. 1.3 Required knowledge The reader must be familiar with general telecommunications principles. 1.4 Acronyms and initialisms The expansions and optional descriptions of most acronyms and initialisms appear in the glossary. 1.5 Assistance and ordering phone numbers Nokia provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL:
https://customer.nokia.com/support/s/
For ordering information, contact your Nokia sales representative. Issue: 01 3FE-47753-AAAA-TCZZA 3 Preface 7368 ISAM ONT BGW320-505 Product Guide 1.6 Nokia quality processes Nokias ONT quality practices are in compliance with TL 9000 requirements. These requirements are documented in the Fixed Networks Quality Manual 3FQ-30146-6000-QRZZA. The quality practices adequately ensure that technical requirements and customer end-point requirements are met. The customer or its representatives may be allowed to perform on-site quality surveillance audits, as agreed upon during contract negotiations 1.7 Safety information For safety information, see the appropriate safety guidelines chapter. 1.8 Documents Documents are available using ALED or OLCS. Procedure 1 To download a ZIP file package of the customer documentation Navigate to https://customer.nokia.com/support/s/ and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. 1 2 3 4 5 6 From the Technical Content for drop-down menu, choose the product. Click on Downloads: Electronic Delivery. Choose Documentation from the drop-down menu and click Next. Select the image from the drop-down menu and click Next. Follow the on-screen directions to download the file. 4 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Preface Procedure 2 To access individual documents Individual PDFs of customer documents are also accessible through the Nokia Customer Support website. 1 2 3 Navigate to https://customer.nokia.com/support/s/ and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. From the Technical Content for drop-down menu, choose the product. Click on Manuals and Guides to display a list of customer documents by title and part number. You can filter this list using the Release drop-down menu. 4 Click on the PDF to open or save the file. 1.9 Special information The following are examples of how special information is presented in this document. Danger Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards. Warning Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems. Caution Caution indicates that the described activity or situation may, or will, cause service interruption. Note A note provides information that is, or may be, of special interest. Issue: 01 3FE-47753-AAAA-TCZZA 5 Preface 7368 ISAM ONT BGW320-505 Product Guide 1.9.1 Procedures with options or substeps When there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals. Procedure 3 Example of options in a procedure At step 1, you can choose option a or b. At step 2, you must do what the step indicates. 1 This step offers two options. You must choose one of the following:
Procedure 4 Example of required substeps in a procedure At step 1, you must perform a series of substeps within a step. At step 2, you must do what the step indicates. 1 This step has a series of substeps that you must perform to complete the step. You must perform the following substeps:
This is one option. This is another option. 2 You must perform this step. a b i ii This is the first substep. This is the second substep. iii This is the third substep. 2 You must perform this step. 6 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Preface 1.10 Multiple PDF document search You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a common term. Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file. Note The PDF files in which you search must be in the same folder. Procedure 5 To search multiple PDF files for a common term Open Adobe Acrobat Reader. Choose EditSearch from the Acrobat Reader main menu. The Search PDF panel appears. Enter the search criteria. Click on the All PDF Documents In radio button. Select the folder in which to search using the drop-down menu. Click on the Search button. Acrobat Reader displays the search results. You can expand the entries for each document by clicking on the + symbol. 1 2 3 4 5 6 Issue: 01 3FE-47753-AAAA-TCZZA 7 Preface 7368 ISAM ONT BGW320-505 Product Guide 8 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Table of contents 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.9.1 1.10 2 2.1 2.1.1 2.1.2 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.3 2.3.1 2.3.2 2.3.3 2.4 2.5 2.5.1 2.5.2 2.6 3 3.1 3.2 3.2.1 3.3 3.4 3.4.1 3.5 3.6 3.7 3.8 3.8.1 3.8.2 3.8.3 Preface.............................................................................................3 Scope ..........................................................................................................3 Audience......................................................................................................3 Required knowledge....................................................................................3 Acronyms and initialisms .............................................................................3 Assistance and ordering phone numbers ....................................................3 Nokia quality processes...............................................................................4 Safety information........................................................................................4 Documents ..................................................................................................4 Special information ......................................................................................5 Procedures with options or substeps...........................................................6 Multiple PDF document search ...................................................................7 ANSI ONT safety guidelines ........................................................15 Safety instructions .....................................................................................15 Safety instruction boxes in customer documentation ................................15 Safety-related labels..................................................................................16 Safety standards compliance ....................................................................16 EMC, EMI, and ESD standards compliance..............................................17 Equipment safety standard compliance.....................................................17 Environmental standards compliance........................................................18 Resistibility requirements compliance .......................................................18 Electrical safety guidelines ........................................................................18 Power supplies ..........................................................................................18 Cabling ......................................................................................................18 Protective earth .........................................................................................19 ESD safety guidelines ...............................................................................19 Laser safety guidelines..............................................................................19 Normal laser operation ..............................................................................20 Location class............................................................................................20 Environmental requirements......................................................................20 BGW320-505 unit data sheet .......................................................21 BGW320-505 part numbers and identification...........................................21 BGW320-505 general description .............................................................22 TR69 authentication using TLS and CA certificates ..................................26 BGW320-505 software and installation feature support ............................26 BGW320-505 interfaces and interface capacity ........................................27 BGW320-505 connections and components .............................................27 BGW320-505 service LEDs.......................................................................28 BGW320-505 detailed specifications.........................................................29 BGW320-505 GEM ports and T-CONTs ...................................................30 BGW320-505 standards compliance.........................................................30 Responsible party......................................................................................30 Energy-related products standby and off modes compliance....................31 FCC statement ..........................................................................................31 Issue: 01 3FE-47753-AAAA-TCZZA 9 7368 ISAM ONT BGW320-505 Product Guide 3.8.4 3.9 3.9.1 3.9.1.1 3.9.1.2 3.9.1.3 3.9.2 4 4.1 4.2 4.3 4.4 4.5 5 5.1 5.2 5.3 5.4 5.5 FCC Radiation Exposure Statement .........................................................32 BGW320-505 special considerations ........................................................32 Wi-Fi service..............................................................................................32 Wi-Fi physical features ..............................................................................32 Wi-Fi standards and certifications .............................................................33 Wi-Fi GUI features.....................................................................................33 BGW320-505 ONT considerations and limitations ....................................33 Install an BGW320-505 indoor ONT ............................................35 Purpose .....................................................................................................35 General......................................................................................................35 Prerequisites..............................................................................................35 Safety information......................................................................................36 Procedure ..................................................................................................37 Replace an BGW320-505 indoor ONT .........................................41 Purpose .....................................................................................................41 General......................................................................................................41 Prerequisites..............................................................................................41 Safety information......................................................................................42 Procedure ..................................................................................................43 10 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide List of figures 3 Figure 1 Figure 2 Figure 3 Figure 4 4 Figure 5 5 Figure 6 BGW320-505 unit data sheet .......................................................21 BGW320-505 ONT unit .............................................................................23 BGW320-505 ONT bottom view ................................................................24 BGW320-505 ONT front and side view .....................................................24 BGW320-505 ONT connections ................................................................25 Install an BGW320-505 indoor ONT ............................................35 BGW320-505 ONT connections ................................................................38 Replace an BGW320-505 indoor ONT .........................................41 BGW320-505 ONT connections ................................................................44 Issue: 01 3FE-47753-AAAA-TCZZA 11 7368 ISAM ONT BGW320-505 Product Guide 12 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide List of tables 2 Table 1 3 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 ANSI ONT safety guidelines ........................................................15 Safety labels ..............................................................................................16 BGW320-505 unit data sheet .......................................................21 Identification of BGW320-505 indoor ONT ................................................21 BGW320-505 indoor ONT interface connection capacity..........................27 BGW320-505 indoor ONT physical connections .......................................27 BGW320-505 service LED indications ......................................................28 BGW320-505 indoor ONT physical specifications.....................................29 BGW320-505 indoor ONT power consumption specifications ..................29 BGW320-505 indoor ONT environmental specifications ...........................30 BGW320-505 indoor ONT capacity for GEM ports and T-CONTs ............30 Responsible party contact information ......................................................31 BGW320-505 ONT considerations and limitations ....................................33 Issue: 01 3FE-47753-AAAA-TCZZA 13 7368 ISAM ONT BGW320-505 Product Guide 14 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide ANSI ONT safety guidelines 2 ANSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals or units (ONTs or ONUs) in the North American or ANSI market. 2.1 Safety instructions This section describes the safety instructions that are provided in the ONT customer documentation and on the equipment. 2.1.1 Safety instruction boxes in customer documentation The safety instruction boxes are provided in the ONT customer documentation. Observe the instructions to meet safety requirements. The following is an example of the Danger box. Danger Possibility of personal injury. The Danger box indicates that the described activity or situation may pose a threat to personal safety. It calls attention to a situation or procedure which, if not correctly performed or adhered to, may result in death or serious physical harm. Do not proceed beyond a Danger box until the indicated conditions are fully understood and met. The following is an example of the Warning box. Warning 1 Possibility of equipment damage. Warning 2 Possibility of data loss. The Warning box indicates that the described activity or situation may, or will, cause equipment damage, loss of data, or serious performance problems. It identifies a possible equipment-damaging situation or provides essential information to avoid the degradation of system operations or data. Do not proceed beyond a warning until the indicated conditions are fully understood and met. Issue: 01 3FE-47753-AAAA-TCZZA 15 ANSI ONT safety guidelines 7368 ISAM ONT BGW320-505 Product Guide The following is an example of the Caution box. Caution 1 Possibility of service interruption. Caution 2 Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box. Note Information of special interest. The Note box provides information that assists the personnel working with ONTs. It does not provide safety-related instructions. 2.1.2 Safety-related labels The ONT equipment is labeled with specific safety compliance information and instructions that are related to a variant of the ONT. Observe the instructions on the safety labels. Table 1 provides examples of the text in the various ONT safety labels. Table 1 Safety labels Description CE marking Label text There are various CE symbols for CE compliance. 2.2 Safety standards compliance This section describes the ONT compliance with North American safety standards. Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 16 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide ANSI ONT safety guidelines 2.2.1 EMC, EMI, and ESD standards compliance The ONT equipment complies with the following requirements:
Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Subpart C, and Subpart E, Class A requirements for OLT equipment SPS-1019_Reliability_Env_Mech v2_5_REL_07-17-17, including sections:
3.3 ESD Test 3.4 Surge Test 6.8 EMC Shielding 8.13 FCC Certification - Intentional Radiators 8.14 FCC Certification - Unintentional Radiators EN 61000-4-4 Testing and measurement techniques - Electrical fast transient/burst immunity test This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is needed. Consult the dealer or an experienced radio/TV technician for help. 2.2.2 Equipment safety standard compliance The ONT equipment complies with the requirements of UL60950-1 and Indoor ONTs to Information Technology Equipment (ITE). Issue: 01 3FE-47753-AAAA-TCZZA 17 ANSI ONT safety guidelines 7368 ISAM ONT BGW320-505 Product Guide 2.2.3 Environmental standards compliance The ONT equipment complies with the following standards:
SPS-1019_Reliability_Env_Mech v2_5_REL_07-17-17 Section 6 Environmental Requirements 2.2.4 Resistibility requirements compliance The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to overvoltage and overcurrents. 2.3 Electrical safety guidelines This section provides the electrical safety guidelines for the ONT equipment. Note The ONTs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards. 2.3.1 Power supplies The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use greatly increases the danger of damage to equipment or property. 2.3.2 Cabling The following are the guidelines regarding cables used for the ONT equipment:
Use only cables approved by the relevant national electrical code. The ONTs have been evaluated for use with external POTS wiring without primary protection that may not exceed 140 ft (43 m) in reach. However, the power cable must not exceed 100 ft (31 m). 18 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide ANSI ONT safety guidelines 2.3.3 Protective earth Earthing and bonding of the ONTs must comply with the requirements of NEC article 250 or local electrical codes. 2.4 ESD safety guidelines The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD instructions when they handle the ONT equipment. Caution This equipment is ESD sensitive. Proper ESD protections should be used when entering the TELCO Access portion of the ONT. During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD. Nokia recommends that you prepare the site before you install the ONT equipment. In addition, you must control relative humidity, use static dissipating material for furniture or flooring, and restrict the use of air conditioning. 2.5 Laser safety guidelines Observe the following instructions when you perform installation, operations, and maintenance tasks on the ONT equipment. Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system. Danger There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam. Observe the following danger for laser hazard. Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules. Danger Possibility of equipment damage. Risk of eye damage by laser radiation. Issue: 01 3FE-47753-AAAA-TCZZA 19 ANSI ONT safety guidelines 7368 ISAM ONT BGW320-505 Product Guide 2.5.1 Normal laser operation In normal operation, fiber cable laser radiation is always off until it receives signal from the line terminal card. Eyes can be damaged when they exposed to a laser beam. Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module. Danger Risk of eye damage by laser radiation. 2.5.2 Location class Use cable supports and guides to protect the receptacles from strain. 2.6 Environmental requirements See the ONT technical specification documentation for temperature ranges for ONTs. 20 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet 3 BGW320-505 unit data sheet 3.1 BGW320-505 part numbers and identification 3.2 BGW320-505 general description 3.3 BGW320-505 software and installation feature support 3.4 BGW320-505 interfaces and interface capacity 3.5 BGW320-505 service LEDs 3.6 BGW320-505 detailed specifications 3.7 BGW320-505 GEM ports and T-CONTs 3.8 BGW320-505 standards compliance 3.9 BGW320-505 special considerations 3.1 BGW320-505 part numbers and identification Table 2 provides part numbers and identification information for the BGW320-505 indoor ONT. Table 2 Identification of BGW320-505 indoor ONT Ordering kit part number Provisioning number Description CLEI CPR ECI/
Bar code 3FE 47753 AA 3FE 47753 AA
(Customer-specific variant) Package P ONT unit with one RJ-14 POTS port, three 10/100/1000 BaseT Ethernet interfaces, and one 5G/2.5G/1G Ethernet port. This ONT has one USB 2.0 port with a Type A connector. This ONT also supports tri-band Wi-Fi: 5 GHz low-band, 5 GHz high-band, and 2.4 GHz. 3FE 48263 AA 3FE 48263 AA
(Customer-specific variant) Package P ONT unit with one RJ-14 POTS port, three 10/100/1000 BaseT Ethernet interfaces, and one 5G/2.5G/1G Ethernet port. BVMG400 BRA 474079 This ONT has one USB 2.0 port with a Type A connector. This ONT also supports tri-band Wi-Fi: 5 GHz low-band, 5 GHz high-band, and 2.4 GHz. Comes with a 3-pin AC/DC U.S. power adapter with AC cable. Issue: 01 3FE-47753-AAAA-TCZZA 21 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide 3.2 BGW320-505 general description BGW320-505 ONTs are designed to cater to business and residential customer requirements. The ONT offers data and video services to the subscriber. When used with an appropriate SFP PON module, the BGW320-505 indoor ONT provides the subscriber interface for the network by terminating the PON interface and converting it to user interfaces that directly connect to subscriber devices. The ONT is compatible with all existing subscriber equipment, including analog phones with both tone and rotary dial capabilities, cordless phones, modems, fax machines, and caller ID boxes (Type I, Type II, and Type III). BGW320-505 ONTs feature one 5G Ethernet port. The BGW320-505 also provides three 10/100/1000 BaseT Ethernet ports, 5 GHz low-band, 5 GHz high-band, and 2.4 GHz. The ONT provides one POTS port each with an RJ-14 connector. The ONT also features a power supply connection, a reset button, one USB 2.0 Type A port, and WPS button. BGW320-505 ONTs can be placed on a flat surface, such as a desk or shelf. Figure 1 shows the ONT unit. 22 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet Figure 1 BGW320-505 ONT unit Figure 2 shows the bottom of the ONT. Issue: 01 3FE-47753-AAAA-TCZZA 23 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide Figure 2 BGW320-505 ONT bottom view Figure 3 shows the front and side views of the BGW320-505 ONT. A WPS button is visible on the front of the unit. Figure 3 BGW320-505 ONT front and side view Front Side 28516 Figure 4 shows the physical connections for the BGW320-505 indoor ONT. 24 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet Figure 4 BGW320-505 ONT connections BGW320-505 indoor ONTs provide the following functions:
5 Gbps interface supports 100M/1G/2.5G/5G auto negotiation Three 10/100/1000 Base T Ethernet ports with auto negotiation and MDI/MDIX auto sensing One POTS port for carrier grade voice services One USB 2.0 Type A port Triple-Play services, including voice, video and high-speed Internet access; the maximum transmit power is 9 dBm. Traffic classification and QoS capability Support for fax services Built-in layer 2 switch; Line Rate L2 traffic 1 GB RAM and 4 GB EMMC memory card in the board Optics that support received signal strength indication (RSSI) Supports 802.11ac, 802.11g, 802.11n, and 802.11ax IP video distribution Issue: 01 3FE-47753-AAAA-TCZZA 25 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide WPS 64/128 WEP encryption WPA, WPA-PSK/TKIP WPA2, WPA2-PSK/AES VLAN tagging/detagging and marking/remarking of IEEE 802.1p per Ethernet port Dying gasp support SIP voice support DTMF dialing Echo cancellation (G.168) Caller ID, call waiting, call hold, 3-way calling, call transfer, message waiting Forward Error Correction (FEC) Frame Check Sequence (FCS) error counter Support for multiple SSIDs (private and public instances Routed mode per LAN port DHCP client/server DNS server/client Network Address Translation (NAT) Network Address Port Translation (NAPT) Traffic classification and QoS capability OMCI, TR-069, and Web GUI management support Performance monitoring and alarm reporting Remote software image downloading and activation Multi-level firewall and ACL IGMP snooping and proxy (v2/v3) IP/MAC/URL filter 3.2.1 TR69 authentication using TLS and CA certificates BGW320-505 ONTs support TLS, as well as ACS authentication using SHA-256 pre-installed certificates. If the URL is set to the https://... format, by default, the connection will use TLS without authentication mode. The ONT can also authenticate the ACS using a pre-installed CA certificate. 3.3 BGW320-505 software and installation feature support For information on installing or replacing the BGW320-505, see:
Install an BGW320-505 indoor ONT Replace an BGW320-505 indoor ONT 26 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet For information on the following topics, see the 7368 ISAM ONT Product Overview Guide:
Ethernet interface specifications POTS interface specifications RSSI specifications Wi-Fi specifications ONT optical budget ONT management using an ONT interface 3.4 BGW320-505 interfaces and interface capacity Table 3 describes the supported interfaces and interface capacity for BGW320-505 indoor ONTs. Table 3 BGW320-505 indoor ONT interface connection capacity ONT type and model Maximum capacity 10/100/1000 BaseT 5G Ethernet port 5 GHz low-band Wi-Fi (1) 5 GHz high-band Wi-Fi (1) 2.4 GHz Wi-Fi (1) SFP+
ONT BGW320-505 3 1 1 1 1 1 1 Notes
(1) Supported wirelessly. 3.4.1 BGW320-505 connections and components Table 4 describes the physical connections for the BGW320-505 indoor ONT. Table 4 BGW320-505 indoor ONT physical connections Connection Description ONT One ONT connection is supported through an RJ-45 cable. The ONT connection provides Ethernet access to home, Internet access, and POTS services. Ethernet ports
(LAN 1 to 4 three GE and one 5 GE) These connections are provided through Ethernet RJ-45 cables. Up to three 10/100/1000 Base-T Ethernet interfaces are supported. The Ethernet ports can support both data and in-band video services on all four interfaces. The 5G Ethernet port is also provided through an RJ-45 cable. One 5G connection is supported.
(1 of 2) Issue: 01 3FE-47753-AAAA-TCZZA 27 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide Connection Description Reset button Phone
(POTS) Power input Pressing the Reset button for less than 10 seconds reboots the ONT; pressing the Reset button for 10 seconds resets the ONT to its factory defaults. This connection is provided through one RJ-14 POTS port. This connection is provided through a power cable with a Delta Electronics EPS48R0-16 2-pin connector. Use only power adapters supplied by AT&T. The use of any non-approved power adapter may cause damage to persons or equipment. Make sure that all power cord connectors are securely and completely plugged into receptacles. Do not use the power adapter in an outdoor environment or any wet locations. Protect the power adapter from liquids. The conditions above may cause fire, short circuit, electrocution or shock injury. This connection is provided through one USB 2.0 Type A port. The voltage rate is 5V. This connection is provided through a SFP+ cage that uses an optical fiber cable. One SFP+ connection is supported. WPS button Located on the front of the ONT, the Wi-Fi Protected Setup button enables and disables WLAN data encryption. Supports 802.11ac, 802.11g, 802.11n, and 802.11ax. USB SFP
(2 of 2) 3.5 BGW320-505 service LEDs The front of the BGW320-505 functions as a multi-color service LED indicator. The LED color and pulse rate acts as a signal to the user, which indicates the state of the BGW320 and the quality of its backhaul link. Table 5 provides the service LED descriptions for the BGW320-505. Table 5 BGW320-505 service LED indications LED color LED behavior LED behavior description Off White Off Power off White solid IP service is established White flashing (Slow) Attempting a broadband connection; for example, the DSL is attempting to synchronize for the DSL. White flashing (Fast) Attempting an IEEE 802.1X authentication, or trying to obtain DHCP information. Orange Orange flashing A software upgrade is in progress. A Power-On Self-Test (POST) is in progress.
(1 of 2) 28 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet LED color LED behavior LED behavior description Yellow Yellow flashing Red Red flashing (Slow) One or more configured VoIP lines are not registered with a SIP proxy server. No signal on a particular broadband connection. The connection is configured for use. No signal on one pair of a bonded-pair connection (as identified through manual or G.997.1 communication). Broadband connection fails to be established for more than three consecutive minutes, or there is no signal on all broadband connections. Red flashing (Fast) The device is attempting to connect to an IP and failed. RedPOST failure
(Not bootable) A device malfunction has occurred or the device is overheating.
(2 of 2) 3.6 BGW320-505 detailed specifications Table 6 lists the physical specifications for the BGW320-505 indoor ONT. Table 6 BGW320-505 indoor ONT physical specifications Description Length Width Height Weight [within 0.5 lb (0.23 kg)]
Specification 7.8 in. (200 mm) 3.9 in. (100 mm) 7.5 in. (191 mm) 3.8 lb (1.742 kg) Table 7 lists the power consumption specifications for the BGW320-505 indoor ONT. Table 7 BGW320-505 indoor ONT power consumption specifications Mnemonic Condition Maximum power (Not to exceed) Minimum power Condition BGW320-505 41.73 W All ports operating with full loading, dual 5x REN 4.66 W Idle Table 8 lists the environmental specifications for the BGW320-505 indoor ONT. Issue: 01 3FE-47753-AAAA-TCZZA 29 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide Table 8 BGW320-505 indoor ONT environmental specifications Mounting method Desk or shelf Temperature range and humidity Altitude Operating: 32F to 107F (0C to
+41.7C) ambient temperature 5% to 95% relative humidity, non-condensing at 40C Contact your Nokia technical support representative for more information 3.7 BGW320-505 GEM ports and T-CONTs Table 9 lists the maximum number of supported T-CONTs and GEM ports. Table 9 BGW320-505 indoor ONT capacity for GEM ports and T-CONTs BGW320-505 ONT Maximum Notes GEM ports per indoor ONT T-CONTs per indoor ONT 256 40 3.8 BGW320-505 standards compliance BGW320-505 indoor ONTs are compliant with the following standards:
EN 61000-4-2 Testing and measurement techniques - Electrical fast transient/burst immunity test EN 61000-4-2 Testing and measurement techniques - Electrostatic discharge immunity test EN 61000-4-2 Testing and measurement techniques - Immunity to conducted disturbances induced by radio frequency fields EN 61000-4-2 Testing and measurement techniques - Radiated, radio frequency, electromagnetic field immunity test FCC CFR 47, Part 15, Subparts B, C, and E. 3.8.1 Responsible party Table 10 lists the party in the US responsible for this ONT. 30 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet Table 10 Responsible party contact information Legal Company name Nokia USA Inc. Address Phone, Fax
+1 866 582-3688 2301 SUGAR BUSH RD. STE 300, RALEIGH, NC 27612 3.8.2 Energy-related products standby and off modes compliance Hereby, Nokia declares that the BGW320-505 ONTs are in compliance with the essential requirements and other relevant provisions of Directive 2009/125/EC together with Commission Regulation (EC) No 1275/2008 and Commission Regulation (EC) No 801/2013. The BGW320-505 ONTS qualify as equipment with high network availability (HiNA) functionality. Since the main purpose of BGW320-505 ONTs is to provide network functionality with HiNA 7 days /24 hours, the modes Off/Standby, Power Management, and Networked Standby are inappropriate. For information about the type and number of network ports, see BGW320-505 interfaces and interface capacity in this chapter. For information about power consumption, see BGW320-505 detailed specifications in this chapter. 3.8.3 FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Issue: 01 3FE-47753-AAAA-TCZZA 31 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide 3.8.4 FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1 this device may not cause harmful interference, and 2 this device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 3.9 BGW320-505 special considerations BGW320-505 are package P ONTs. 3.9.1 Wi-Fi service BGW320-505 indoor ONTs feature Wi-Fi service as well as voice and data services. Wi-Fi is a wireless networking technology that uses radio waves to provide wireless HSI and network connections. This ONT complies with the IEEE 802.11 standards, which the Wi-Fi Alliance defines as the basis for Wi-Fi technology. 3.9.1.1 Wi-Fi physical features BGW320-505 indoor ONTs have one Wi-Fi Protected Setup (WPS) push button
(located on the front of the ONT) to enable and disable WLAN data encryption. 32 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide BGW320-505 unit data sheet 3.9.1.2 Wi-Fi standards and certifications The Wi-Fi service on BGW320-505 indoor ONTs supports the following IEEE standards and Wi-Fi Alliance certifications:
Certified for Wi-Fi 802.11ac/b/g/n/ax standards WPA support including WPA-PSK Certified for WPA2-Personal 3.9.1.3 Wi-Fi GUI features BGW320-505 indoor ONTs have HTML-based Wi-Fi configuration GUIs. 3.9.2 BGW320-505 ONT considerations and limitations Table 11 lists the considerations and limitations for Package P BGW320-505 ONTs. Table 11 BGW320-505 ONT considerations and limitations Considerations and limitations This device is restricted to indoor use in accordance with proper ventilation (as described in Step 1 of Section 4.5 of the chapter Install an BGW320-505 indoor ONT, and temperature requirements, as described in Section 3.6. Issue: 01 3FE-47753-AAAA-TCZZA 33 BGW320-505 unit data sheet 7368 ISAM ONT BGW320-505 Product Guide 34 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Install an BGW320-505 indoor ONT 4 Install an BGW320-505 indoor ONT 4.1 Purpose 4.2 General 4.3 Prerequisites 4.4 Safety information 4.5 Procedure 4.1 Purpose 4.2 General This chapter provides the steps to install a BGW320-505 indoor ONT. The steps listed in this chapter describe mounting and cabling for BGW320-505 indoor ONTs. 4.3 Prerequisites You need the following items before beginning the installation:
all required cables Issue: 01 3FE-47753-AAAA-TCZZA 35 Install an BGW320-505 indoor ONT 7368 ISAM ONT BGW320-505 Product Guide 4.4 Safety information Read the following safety information before installing the unit. Danger 1 Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits. Danger 2 Make sure all sources of power are turned off and have no live voltages present on feed lines or terminals. Use a voltmeter to measure for voltage before proceeding. Danger 3 Always contact the local utility company before connecting the enclosure to the utilities. Warning 1 This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT. Warning 2 Do not directly connect the 10G PON ONT to the 10G PON OLT. Caution Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit. Note 1 Observe the local and national laws and regulations that may be applicable to this installation. Note 2 Observe the following:
The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC. The indoor ONT may require the presence of a fiber termination, which must be installed by qualified service personnel. Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use. See the detailed specifications in the BGW320-505 unit data sheet for the temperature ranges for these ONTs. 36 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Install an BGW320-505 indoor ONT 4.5 Procedure Use this procedure to install an BGW320-505 indoor ONT. 1 Place the indoor ONT unit on a flat surface, such as a desk or shelf. Note The BGW320-505 ONT cannot be stacked with another ONT or with other equipment. The ONT mounting requirements are:
place the unit in a vertical upright position with the feet and grill facing down and the flat top facing up allow a minimum 100 mm clearance above the top cover do not place any heat source directly above the top cover or below the bottom cover Warning There is a risk of overheating if the BGW320 is not properly ventilated. The unit should not be placed in an enclosed cabinet or location without proper ventilation. Make sure the temperature requirement described in Section 3.6 are adhered to. 2 Review the connection locations, as shown in Figure 5. Issue: 01 3FE-47753-AAAA-TCZZA 37 Install an BGW320-505 indoor ONT 7368 ISAM ONT BGW320-505 Product Guide Figure 5 BGW320-505 ONT connections 3 Connect the Ethernet cables to the ONT and GE ports; see Figure 5 for the location of these ports. 4 Connect a telephone to the RJ-14 POTS port. Contact your service provider for details, especially if you have an alarm system. 38 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Install an BGW320-505 indoor ONT 5 Connect the fiber optic cable with an SFP adapter into the SFP+ connector; see Figure 5 for the location of the SFP connector. Danger Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. Warning Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber. Note Fiber cable preparation varies depending on the type and size of the inside or outside plant fiber cable being spliced to the SC/APC fiber optic pigtail cable. 6 Install the power supply according to manufacturer specifications. Note Observe the following:
Units must be powered by a Listed or CE approved and marked limited power source power supply with a minimum output rate of 12VDC, 4A. Power up the ONT unit by inserting the power cable. 7 8 9 If applicable, use the WPS button to connect additional Wi-FI devices to the ONT. Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. 10 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide. 11 If necessary, reset the ONT. i ii Locate the Reset button on a BGW320-505 indoor ONT as shown in Figure 5. Press the Reset button for less than 10 seconds to reboot the ONT. Press the Reset button for 10 seconds to reset the ONT to its factory defaults. 12 STOP. This procedure is complete. Issue: 01 3FE-47753-AAAA-TCZZA 39 Install an BGW320-505 indoor ONT 7368 ISAM ONT BGW320-505 Product Guide 40 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Replace an BGW320-505 indoor ONT 5 Replace an BGW320-505 indoor ONT 5.1 Purpose 5.2 General 5.3 Prerequisites 5.4 Safety information 5.5 Procedure 5.1 Purpose 5.2 General This chapter provides the steps to replace BGW320-505 indoor ONTs. The steps listed in this chapter describe mounting and cabling for BGW320-505 indoor ONTs. 5.3 Prerequisites You need the following items before beginning the installation:
all required cables Issue: 01 3FE-47753-AAAA-TCZZA 41 Replace an BGW320-505 indoor ONT 7368 ISAM ONT BGW320-505 Product Guide 5.4 Safety information Read the following safety information before replacing the unit. Danger 1 Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits. Danger 2 Make sure all sources of power are turned off and have no live voltages present on feed lines or terminals. Use a voltmeter to measure for voltage before proceeding. Danger 3 Always contact the local utility company before connecting the enclosure to the utilities. Warning 1 This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT. Warning 2 Do not directly connect the 10G PON ONT to the 10G PON OLT. Caution Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit. Note 1 Observe the local and national laws and regulations that may be applicable to this installation. Note 2 Observe the following:
The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC. The indoor ONT may require the presence of fiber termination, which must be installed by qualified service personnel. Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use. See the detailed specifications in the BGW320-505 unit data sheet for the ONT temperature ranges for these ONTs. 42 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Replace an BGW320-505 indoor ONT 5.5 Procedure Use this procedure to replace an BGW320-505 indoor ONT. 1 Deactivate the ONT services at the P-OLT. If you are using the SLID feature, this step is not required. The ONT and the services can remain in service (IS). i Use the RTRV-ONT command to verify the ONT status and th associated services. Record the serial number or the SLID of the ONT displayed in the command output. RTRV-ONT::ONT-1-1-1-1-1;
ii If the ONT is in service, place the ONT in OOS state. Example:
Example:
ED-ONT::ONT-1-1-1-1-1;
2 Power down the unit by disconnecting the power cable; see Figure 6 for the power input. Issue: 01 3FE-47753-AAAA-TCZZA 43 Replace an BGW320-505 indoor ONT 7368 ISAM ONT BGW320-505 Product Guide Figure 6 BGW320-505 ONT connections 3 4 5 6 Disconnect the telephone from the RJ-14 POTS port. Disconnect the fiber optic cable with an SFP adapter from the SFP+ connector. Danger Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. i ii Unplug the fiber optic cable from the SFP+ connector. Attach a fiber dust cover to the end of the SFP+ connector. Replace the ONT with a new unit. For details, Install an BGW320-505 indoor ONT. Connect the Ethernet cables to the ONT and GE ports; see Figure 6 for the location of these ports. 44 3FE-47753-AAAA-TCZZA Issue: 01 7368 ISAM ONT BGW320-505 Product Guide Replace an BGW320-505 indoor ONT 7 Connect a telephone to the RJ-14 POTS port. Contact your service provider for details, especially if you have an alarm system. 8 Connect the fiber optic cable with the SFP adapter into the SFP connector. Figure 6 shows the location of the fiber optic connector. Danger Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. Warning Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber. 9 Install the power supply according to manufacturer specifications. Note Observe the following:
Units must be powered by a Listed or CE approved and marked limited power source power supply with a minimum output rate of 12VDC, 4A. 10 Power up the unit by connecting the power cable; see Figure 6 for the location of the power input. i ii i ii 11 If applicable, use the WPS button to connect additional Wi-Fi devices to the ONT. If applicable, use the WPS button to connect additional Wi-FI devices to the ONT. Press the WPS buttons to change the status of the Wi-Fi Protected Service. 12 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. 13 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide. 14 If necessary, reset the ONT. Locate the Reset button on a BGW320-505 indoor ONT as shown in Figure 6. Press the Reset button for less than 10 seconds to reboot the ONT. Press the Reset button for 10 seconds to reset the ONT to its factory defaults. 15 STOP. This procedure is complete. Issue: 01 3FE-47753-AAAA-TCZZA 45 Replace an BGW320-505 indoor ONT 7368 ISAM ONT BGW320-505 Product Guide 46 3FE-47753-AAAA-TCZZA Issue: 01 Customer document and product support Customer documentation Customer Documentation Welcome Page Technical Support Customer Documentation Technical Support Documentation feedback Customer Documentation Feedback Copyright 2019 Nokia. 3FE-47753-AAAA-TCZZA