INSTR,INSTL,PS15EMZ5-1 P/N 10008371 X9,GO CONTROL ; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500 x 11.000; TOLERANCE .125; SCALE: 1-1; PAGE 1 OF 2 PRINTERS INSTRUCTIONS:
PS15EMZ5-1 Z-Wave Radio Frequency (RF) Controlled, 120 VAC 15 Amp, Plug-In Switch Series 500 NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the mesh network is dependent on it knowing its location with respect to other nodes. You cannot test bench con gure this unit, then install. Bottom of Appliance Module showing 3 prong plug-in PS15EMZ5-1 PLUG-IN MODULE The GoControl family of Z-Wave certi ed wireless lighting products (smart LED xtures, bulbs, switches, dimmers, outlets, plug-in modules) Control Products
(thermostats, irrigation controller and garage door controller)and Sensors ( ood, leak, alert sounder, motion sensor and door/window sensor) bring a new level of intelligent wireless Home Automation capability to commercial and residential environments. The Z-Wave wireless protocol is an international wireless standard for remote home automation, security and other applications. This product can be included and operated in any Z-Wave network with other Z-Wave certi ed devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. GoControl Z-Wave products are easy to install, are Z-Wave certi ed, and allow dealers to create an integrated wireless network with nearly limitless expansion and interoperability with security, energy management, home entertainment, appliances, and more. The PS15EMZ5-1 is a simple Plug & Play Home Automation device that lets you control any lighting or small appliance while monitoring the amount of energy being used. Bright multi-colored LEDs provide an instant indicatioon of the energy being used while simultaneously reporting this information to your Z-Wave hub that may be used for energy monitoring and analysis. Z-WAVE PLUS FEATURES The PS15EMZ5-1 contains a Z-Wave 500 Series Module that supports Z-Wave Plus features. A Z-Wave certi ed portable or stationary Controller can communicate with the Z-Wave 500 Series Module. Depending on the capability of the Controller or gateway software, the following operations can be performed with the PS15EMZ5-1. Refer to the Controller or gateway manual for details.
Turn the load ON and OFF.
Add or Remove the PS15EMZ5-1.
Assign the PS15EMZ5-1 to a specific Group/Scene and/or to include the load as part of ALL ON or ALL OFF system commands.
Over-the-air firmware update by the gateway or static Controller.
Lifeline function which automatically notifies the associated modules and the network that a manually reset device is no longer in the network, thus, the corresponding association becomes invalid.
Monitors the amount of energy being used and reports the current usage to the Z-Wave controller INSTALLATION Adding to a network:
Refer to your Controller operating instructions to add this switch under the command of the Wireless Controller. 1. With your Controller in Discovery or Add Mode, tap the button on the face of the outlet. The LED will blink slowly when in ADD Mode. 2. You should see an indication on your Controller that the device was added to the network and the LED will stop blinking. 3. The device will appear in the list of Switches. It should display as a switch. If the Controller/Gateway shows the addition failed, repeat Steps 1-3. NOTE: If you have trouble adding the PS15EMZ5-1 to a group it may be that the Home ID and Node ID were not cleared from it after testing. You must rst RESET UNIT to remove it from the network. Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed from a group, it functions as a repeater (only). RESET UNIT removes it completely from the network. To Reset Unit (If Required):
In the event that your primary Controller is lost or otherwise inoperable, to reset the PS15EMZ5-1 and clear all network information, follow these steps:
1. Tap the button on the face of the outlet ve (5) times. 2. Press and hold the button for 15 seconds. The LED will increasingly blink faster to indicate that a Reset is taking place. 3. LED will turn off when reset is complete. Copyright 2016 Nortek Security & Control LLC Removing from a network:
The PS15EMZ5-1 can be removed from the network by the Controller/Gateway. Refer to the Controller operating instructions for details. 1. Set the Controller into Removal Mode and follow its instruction to delete the PS15EMZ5-1 from the Controller. 2. Remove the switch by tapping the button on the face of the outlet 2 times. The LED will begin blinking slowly for 10 seconds indicating that it has been removed. 3. You should see an indication on your Controller that the device was removed from the network. BASIC OPERATION Local Control The button on the PS15EMZ5-1 allows the user to:
Turn the attached load on or off.
Tapping the button on the face of the outlet turns the load attached ON or OFF. Night Light To act as a night light, the LED on the PS15EMZ5-1 will turn ON when the load attached is OFF. However, the LED can be user con gured to turn ON, when the load attached is ON, if so desired. See CONFIGURATION section. Energy Monitoring PS15EMZ5-1 reports the total accumulated Kilowatt Hours (kWh) and the instantaneous Watts being consumed by the load. Parameter Length Valid Values Con guration Option 13 1 Byte 0 1-255 Automatic reporting OFF Number of minutes between automatic reporting
(Default = 6) Con guration Parameter 13 con gures the rate at which the energy readings are reported. If the maximum kWh value that can be reported is reached (21,474 kWh), then it will remain at the maximum level until reset to 0 using the Controller software. To reset, the total accumulated kWh used by the PS15EMZ5-1 the Z-Wave controller needs to send a reset command at the request of the user. It will also be reset if the PS15EMZ5-1 is excluded from the Z-Wave network. The Watts reading provides the immediate reading of the power being consumed by the load. The Watts reading takes several seconds to settle so wait a few seconds before reading the energy value when the state of the switch (on / off) has changed. NOTE: If Power Monitoring, see Con guration Section below, is turned OFF the PS15EMZ5-1 will not report any energy use. Remote Control The PS15EMZ5-1 will respond to BASIC and BINARY commands that are part of the Z-Wave system. Refer to your Controllers instructions as to whether your Controller can transmit those commands. Protection Mode The PS15EMZ5-1 supports Protection Mode that is used to disable the button on the front of the device. This eliminates inadvertent activation of the switch. To enable Protection Mode, press the button on the PS15EMZ-1 three times quickly. The LED will blink Purple twice showing that Protection Mode has been enabled. When Enabled the only way to turn ON or OFF the PS15EMZ5-1 is through the Z-Wave controller or Mobile app. If the button on the PS15EMZ5-1 is pressed, the LED will blink Purple twice and have no impact on the attached device. To exit Protection Mode, press the button three times. Associations The PS15EMZ5-1 supports one Group with ve Nodes for lifeline communication. Group 1 must be assigned the Node ID of the Controller to which unsolicited noti cations from the PS15EMZ5-1 will be sent. The Z-Wave Controller should set this Association automatically after inclusion. You can associate up to ve Z-Wave devices to Group 1. For instructions on how to set Lifeline Association please refer to your Controller instructions. 1 INSTR,INSTL,PS15EMZ5-1 P/N 10008371 X8,GO CONTROL ; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500 x 11.000; TOLERANCE .125; SCALE: 1-1; PAGE 2 OF 2 PRINTERS INSTRUCTIONS:
Removing Associations To remove the Associations, if the Controller has recognized the Associations, refer to the Z-Wave Controllers instructions on how to remove Associations. If the Controller has not recognized the Associations, removing the PS15EMZ5-1 from the Z-Wave network will eliminate the Associations. Resetting to Defaults Each con guration Parameter can be set back to its default setting by setting the default bit in the Con guration Set command. See your Controllers instructions on how to do this
(and if it supports it). All con guration commands will be reset to their default state when the PS15EMZ5-1 is excluded from the Z-Wave network by using the Controller to reset the node. ADVANCED OPERATION All On/All Off The PS15EMZ5-1 supports the ALL ON / ALL OFF commands. The PS15EMZ5-1 can be set to respond to ALL ON and ALL OFF commands four different ways. Refer to your Controller for information on how to set the PS15EMZ5-1 to operate in the manner you desire. Some Controllers may be only able to set certain settings of ALL ON/ALL OFF response. The four different ways the PS15EMZ5-1 can be setup to respond to ALL ON and ALL OFF commands are:
1. Responds to ALL ON or the ALL OFF command. 2. Responds to ALL OFF command but will not respond to ALL ON command. 3. Responds to ALL ON command but will not respond to ALL OFF command. 4. Responds to ALL ON and the ALL OFF command. CONFIGURATION The PS15EMZ5-1 supports the Con guration command. Each unit can be con gured to operate slightly differently than how it works when you rst install it. Using the Con guration command you can con gure the following:
LED Intensity You can set the intensity of the LED to t the environment the PS15EMZ5-1 is being used in from off to full brightness. This is done by changing Parameter 2 Parameter Length Valid Values Con guration Option 2 1 Byte 0 - 99 0 = OFF 1 = Very dim 99 = Full Brightness (default) Power Monitoring The PS15EMZ5-1 provides a visual display of the amount of energy being consumed when the switch is turned on by illuminating the LEDs in one of 5 different colors. Energy Use LED Color 0 to 0.02 Amps 0.02 to 2 Amps 2 to 5 Amps 5 to 10 Amps Over 10 Amps The Power monitoring can be turned off utilizing Parameter 11. When turned off, the PS15EMZ5-1 will no longer illuminate the LED to indicate any energy use and periodic reports to the hub on energy use will also be turned off. White Green Blue Yellow Red Parameter Length Valid Values Con guration Option 11 1 Byte 0 1 Power monitoring OFF Power monitoring ON (Default) The duration the LED will change color to indicate the amount of energy being used can be set using Parameter 12. After displaying the energy used color, the LED will revert to OFF or ON
(white) as determinded by con guration parameter #3 Parameter 12 Length 1 Byte Valid Values 1 - 254 Con guration Option Number of seconds LED displays power level usage. Default = 30 255 Power level usage continuous ON Night Light By default, the LED on the PS15EMZ5-1 will turn OFF when the load attached is turned ON. To make the LED turn ON when the load attached is turned ON, set Parameter 3 to a value of 1. Parameter Length Valid Values Con guration Option 3 1 Byte 0 1 2 3 4 LED OFF when the load is on, and ON when the load is off (default mode) LED ON when the load is on, and OFF when the load is off LED is always on LED is always off LED blinks during RF transmissions from or to the device Over-The-Air (OTA) Update A Quadruple tap of the switch enables the rmware update mode. Firmware update mode must be entered before the system Controller sends the rmware update command to begin downloading new rmware. Firmware update mode is enabled for 60 seconds after the quadruple tap. If the Firmware update does not begin before the end of the 60 seconds then rmware update mode is exited returns to normal operation. The LED winks twice per second indicating it is in rmware update mode. SPECIFICATIONS 120 VAC, 60 Hz Power:
Signal (Frequency): 908.42 MHz / 916 MHz Maximum Load:
Resistive: 15 amps (1800 watts) maximum, 120 VAC Range: Up to 130 feet (line of sight) NOTICES Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the United States and other countries. Terms and Conditions pertaining to the sale of this Nortek Security & Control wireless mesh network product are available at http://nortekcontrol.com/terms_conditions.php REGULATORY INFORMATION We, Nortek Security & Control, LLC of 1950 Camino Vida Roble STE 150, Carlsbad, CA 92008,declare under our sole responsibility that the device, PS15EMZ5-1 complies with Part 15 of FCC rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver receiver is connected
Consult the dealer or an experienced radio/TV technician to help. Changes or modi cations not expressly approved by the party responsible for compliance could void the users authority to operate the equipment IC Notice This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. WARRANTY What is Covered?
Nortek Security & Control (NS&C) warrants to consumers who purchase this product for personal, family or household purposes new from NS&C directly or from an authorized NS&C dealer, that the product will be free from defects in materials and workmanship for a period of (1) year from the date of purchase. This warranty only applies if the product is installed at a residence in the 50 United States or District of Columbia, and only at the site of the original installation. It is not transferable. This warranty is not extended to resellers. If a defect exists, NS&C will have you ship the defective part or product to us and we will, at our option, either repair or replace it. This warranty does not cover the cost of labor to remove a defective part or product or to reinstall any repaired or replacement part or product This warranty does not cover defects or damages caused by improper handling, maintenance, storage, installation, removal or re-installation, misuse, non-factory authorized modi cation or alteration, use of incompatible accessories, electrical power problems or surges, impact by foreign objects, accident, re, acts of God, normal wear and tear or shipping damage other than a shipment from NS&C. Note that all NS&C products are designed to be installed, removed and serviced by trained individuals or professionals. Keep your original sales receipt as it will be required to obtain warranty service. This warranty shall not be extended or restarted upon receipt of any repaired or replacement part or product under this warranty. No person is authorized to extend or otherwise modify this warranty. How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at returns@nortek.com. Include your name, address, telephone number, the model number of your product, a copy of your original sales receipt, and a description of the problem. Unless we need to discuss the situation further with you, you will be emailed a Return Authorization Number and shipping instructions. If we need to discuss the situation further with you, we will call or email you. NS&C may require troubleshooting on installed product before a Return Authorization Number is issued. Anything shipped to us without a Return Authorization Number will be automatically returned unopened. You are responsible for the charges for shipment to us, unless you are a California resident. Limitations THE DURATION OF ANY INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. IMPLIED WARRANTY, This warranty gives you speci c legal rights, and you may also have other legal rights which vary from State to State. Copyright 2016 Nortek Security & Control LLC 2 10008371 X9