INSTR,INSTL,ITIDWA - LINEAR P/N: 235345 X6- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000 X 8.500 - FOLDING: 4 FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1 PRINTERS INSTRUCTIONS:
ITIDWA01 UNIVERSAL DOOR/WINDOW TRANSMITTER Installation Instructions USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.com BATTERY INSTALLATION OR REPLACEMENT 1 TWIST SCREWDRIVER IN SLOT ON EITHER SIDE TO OPEN CASE 2 INSTALL TWO CR2032 BATTERIES
+ SIDE UP OBSERVE POLARITY !!!
NOTICE TO USERS IN CALIFORNIA - CR COIN CELL LITHIUM BATTERY INFORMATION: THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM BATTERY WHICH CONTAINS PERCHLORATE MATERIAL - SPECIAL HANDLING MAY APPLY - SEE www.dtsc.ca.gov/hazardouswaste/perchlorate KEEP AWAY FROM SMALL CHILDREN. IF BATTERIES ARE SWALLOWED, PROMPTLY SEE A DOCTOR. DO NOT TRY TO RECHARGE THESE BATTERIES. DISPOSAL OF USED BATTERIES MUST BE MADE IN ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA. TO REMOVE BATTERIES, TWIST SMALL SCREWDRIVER HERE WARNING DANGER OF EXPLOSION IF BATTERY IS INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. TRANSMITTER MOUNTING ATTACH MOUNTING PLATE WITH TWO SCREWS OR USE THE DOUBLE-STICK TAPE 1/2" GAP MAXIMUM !!!
MOUNT MAGNET NEXT TO ALIGNMENT MARKS TRANSMITTER ON DOOR FRAME INSTALLATION TIP: TO MINIMIZE PHYSICAL SHOCK TO THE UNIT, ALWAYS MOUNT THE TRANSMITTER ON THE STATIONARY PART OF THE OPENING NOTE: MOUNTING THE TRANSMITTER WITH DOUBLE-STICK TAPE IS NOT ALLOWED IN UL INSTALLATIONS MAGNET ON DOOR OPENING OR CLOSING THE DOOR TRIGGERS THE TRANSMITTER PRODUCT DESCRIPTION The ITIDWA01 is a battery powered supervised stationary transmitter designed for use with GE security systems. Triggering the transmitter with its built-in magnetic switch sends a digitally coded wireless signal to its companion receiver. The transmitter also has an external input that accepts normally closed (N/C) dry contact devices. The ITIDWA01 can send ve different signal types: fault, restore, low battery, tamper, and status. Receivers must be programmed to the transmitters code before system testing and operation. Refer to the receivers instructions for details on programming. In a typical installation, the magnet is mounted on a door or window and the transmitter is mounted on the frame. When the door or window is opened, the magnet moves away from the transmitter and a fault signal is sent. When the door or window is closed, the magnet returns next to the transmitter and a restore signal is sent. About every 65 minutes the transmitter sends a status signal to update the receiver. If the battery tests low, a low battery signal is included with any transmission. The transmitter is powered from two 3-Volt CR2032 lithium batteries (included). An internal switch detects if the transmitters case is opened. Opening the case will send a tamper signal to the receiver. Two screws and double-stick tape are provided for mounting the transmitter. PROGRAMMING 1 REFER TO THE SECURITY SYSTEM'S INSTRUCTIONS AND PLACE THE RECEIVER IN PROGRAM MODE 2 PRESS AND RELEASE THE TAMPER SWITCH TO SEND A SIGNAL 3 4 5 VERIFY THAT THE TRANSMITTER HAS BEEN "LEARNED" BY THE RECEIVER SET ANY OTHER SYSTEM PROGRAMMING OPTIONS FOR THE TRANSMITTER AFTER INSTALLATION, TEST THE SYSTEM TO VERIFY PROPER OPERATION, CHECK THAT THE SYSTEM INDICATES WHEN THE DOOR IS OPEN OR CLOSED PRESS AND RELEASE THE TAMPER SWITCH SPECIFICATIONS Operating Temperature: 32 to 120 F (0 to 49 C) Operating Relative Humidity: 5 to 95%, non-condensing Operating Frequency: 319.5 MHz Battery Type: Two 3-Volt CR2032 Lithium Batteries FEATURES TRANSMITTER DOUBLE-STICK TAPE MAGNET ALIGNMENT MARKS MAGNET MOUNTING SCREWS EXTERNAL CONTACT LEADS OPTIONAL EXTERNAL CONTACT AN EXTERNAL NORMALLY CLOSED MAGNETIC CONTACT CAN BE CONNECTED TO THE TRANSMITTER NOTE: THE INTERNAL MAGNETIC SWITCH CANNOT BE USED IF AN EXTERNAL CONTACT IS CONNECTED 1 PLUG EXTERNAL CONTACT LEADS INTO THE TRANSMITTER'S EXTERNAL CONTACT CONNECTOR 2 WIRE EXTERNAL CONTACT TO THE LEADS 3 FEET MAXIMUM EXTERNAL CONTACT CONNECTOR MAGNET EXTERNAL NORMALLY CLOSED CONTACT LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linears normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealers warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or pro t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-855-546-3351 for an RPA# and other important details. Any changes or modi cations not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modi cations non approuvs expressment par la partie responsable de la conformit pourrait annuler lautorit de lutilisateur faire fonctionner lquipement. Copyright 2013 Linear Corporation IMPORTANT! Linear radio controls provide a reliable communications link and ll an important need in portable wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modi cations to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 235345 X6