INSTR,INSTL,M4IN1Z-1,GO CONTROL; P/N: 10012103 X4; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500 x 11.000; TOLERANCE .125; SCALE: 1-1 PRINTERS INSTRUCTIONS:
M4IN1Z-1 Wireless Multi-Function Sensor 360 PIR, Temp, Humidity and Light Sensor NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the mesh network is dependent on it knowing its location with respect to other nodes. You cannot test bench con gure this unit, then install. GOCONTROL MINI 4IN1 The GoControl family of Z-Wave certi ed wireless Lighting Products (smart LED xtures, bulbs, switches, dimmers, outlets and plug-in modules) Control Products (thermostats, irrigation controller and garage door controller) and Sensors ( ood, leak, alert sounder, motion sensor and door/window sensor) bring a new level of intelligent wireless Home Automation capability to commercial and residential environments. The Z-Wave wireless protocol is an international wireless standard for remote home automation, security and other applications. This product can be included and operated in any Z-Wave network with other Z-Wave certi ed devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. The M4IN1Z-1 Smart Multifunction Sensor is simple to set up and combines 4 popular functions in a small battery powered footprint: 360 PIR, Temperature, Humidity and Light Sensors. GoControl Z-Wave products are easy to install, are Z-Wave Plus certi ed, and allow dealers to create an integrated wireless network with nearly limitless expansion and interoperability with security, energy management, home entertainment, appliances, and more LIGHT SENSOR
Send an alert if motion is sensed.
Provide the absolute temperature.
Provide the humidity level.
Send an alert when light is present.
Add or Remove Mini 4in1.
Over-the-air firmware update by the gateway or static Controller. INSTALLATION The M4IN1Z-1 can be mounted on a wall or ceiling using the double stick tape
(included). It can also be placed on a table top. 1. Remove the rear cover by pushing button on sensor top. PUSH BUTTON REMOVE REAR COVER SENSOR TOP Figure 2. Removing Rear Cover of Mini 4in1 Sensor 2. Insert 2 AAA batteries (included). The LED will brie y illuminate in RED, AAA BATTERIES Figure 1. M4IN1Z-1 Mini 4in1 Sensor Components PROGRAM SWITCH Z-WAVE PLUS FEATURES The M4IN1Z-1 contains a Z-Wave 500 Series Module that supports Z-Wave Plus features. A Z-Wave certi ed portable or stationary Controller can communicate with the Z-Wave 500 Series Module. Depending on the capability of the Controller or gateway software, the following operations can be performed by Mini 4in1. Refer to the Controller or gateway manual for details. Figure 3. Install Batteries into Sensor Top BLUE, then GREEN. SENSOR TOP 3. Replace the rear cover onto the sensor top. 4. Install in permanent location using provided double stick tape. The M4IN1Z-1 should be mounted (6) six feet from the oor. 5. Press the program switch. The Walk Test LED will ash 5 times if the sensor has not been included in a Z-Wave network. If the LED ashes once, the sensor has been already been included. 1 DETECTING AREA: UNIT: METER TOP VIEW SIDE VIEW CEILING Temperature:
If the present temperature is different than previously recorded and has changed by more than the value in Parameter 2 (see below), the sensor will report the present temperature to the hub. The LED will ash every (3) three minutes to represent the temperature. 5M 0M 9M 0123456 1 2 3 4 5 6M Figure 4.Detecting Area Z-WAVE PROGRAMMING Adding to a Network Refer to your Controller operating instructions to add this switch under the command of the Wireless Controller 1. With your Controller in Discovery or Add Mode, press the Program Switch for 1 (one) second. The Yellow LED will blink. The device will appear in the list of devices and should display as (4) four items: M4IN1Z-1 (Motion), Light Sensor, Temperature Sensor and Humidity Sensor. If the Controller/Gateway shows the addition failed, repeat Steps 1-3. NOTE: If you have trouble adding the M4IN1Z-1 to a group it may be that the Home ID and Node ID were not cleared from it after testing. You must rst RESET UNIT to remove it from the network. Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. RESET UNIT removes it completely from the network. To Reset Unit (if required):
In the event that your primary Controller is lost or otherwise inoperable, to reset the M4IN1Z-1 and clear all network information, follow these steps:
1. Remove cover to trigger the tamper switch. The LED will ash once and send out Alarm Report. 2. Press Program Switch 10 times within 10 seconds. The M4IN1Z-1 will send the Device Reset Locally Noti cation command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable). 3. The M4IN1Z-1 will completely reset to factory defaults. Removing from a Network:
The M4IN1Z-1 can be removed from the network by the Controller/Gateway. Refer to the Controller operating instructions for details. Be sure to select the M4IN1Z-1 (PIR) to remove as the other Sensors are tied to this main device. 1. With your Controller in Remove Mode, press the Program Switch for one
(1) second. 2. You should see an indication on your Controller that the device was removed from the network. Association 1. Press the program switch on the M4IN1Z-1 to initiate the Awake mode. The LED will ash once. 2. Put your Controller into Association, and following its instruction to associate the M4IN1A-1 to other devices. Other Z-Wave Commands Auto Wake Up:
Use Wake Up command to set up the awaking time (from 10 minutes to 1 week) and send the wake up noti cation to the controller. Battery Capacity Detection:
Use Battery Get command to have the battery capacity back in %.
Low Battery Auto Report when power is lower than 2.6V +/-0.1V. It will detect the battery capacity automatically. Temperature Under 59F 60 - 73 F 74 - 82 F 83 - 97 F Over 97 F Sensor Type Scale Size and Precision Multilevel Sensor Report LED Color Green Blue Yellow / Yellow Green Purple Red 0x01 0x00 (C) 0x01 (F) 2 Humidity Report:
If the present humidity is different than previously recorded and has changed by more than the value in Parameter 3(see below), the sensor will report the present illumination. Light Report:
If the present illumination is different than previously recorded and has changed by more than the value in Parameter 4 (see below), the sensor will report the present illumination. Multilevel Sensor Report Sensor Type Scale Size and Precision 0x03 0x00
(%) 2 OPERATION
When a person walks in from of M4IN1Z-1, the sensor will send Basic set On (0xFF) and the Red LED will flash once. Refer to status report as table below. In no movement is detected in (3) three minutes (default), it will send Basic Set OFF (0x00) will be sent and the Red LED will flash once.
The M4IN1Z-1 is equipped with tamper switch. If the tamper switch is triggered ( or the cover is removed), the M4IN1Z-1 will send an Alarm Report. If the tamper switch is closed (or the cover closed), the M4IN1Z-1 will send an Alarm Report.
Supports OTA Firmware update from the controller. Please refer to your controller manual and use COMMAND_CLASS_FIRMWARE_UPDATE_ MD_V2. To proceed with the OTA process. Once the OTA function is successful, make sure to exclude the device and include again before using the device. 2 Alarm V1 Movement &
Tamper Switch 0x07 0x00 (No movement after 3 min.) 0xFF
(Motion detected) Alarm Type Alarm Level Noti cation Type Noti cation Event Noti cation Event Parameter Noti cation V4
(Movement) Noti cation V4
(Tamper Switch) LED Mode Parameter 7 Size 1 bit 0x07 0x07 Value 1 - 3 (Mode 1 - Mode 3) Mode 1LED Turn Off
(Both Temp / PIR Trigger) Mode 2 (Breathing Light Mode) PIR (Quick Flash) Mode 3 LED Quick Flash (Temp / PIR Trigger) 0x03 (Cover removed) 0x00 (Cover closed) 0x03 SPECIFICATIONS Power: 2 - AAA battery (Included) Signal (Frequency): 908.42 MHz / 916 MHz Range: Up to 130 feet line of sight Z-WAVE COMMAND CLASSES 0x08 (Motion detected) 0x00 (No movement after 3 min.) 0x08 (Motion detected) 0x00
(No movement after 3 min.) COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SENSOR_MULTILEVEL_V7 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ZWAVEPLUS_INFO_V2 REGULATORY INFORMATION The M4IN1Z-1is certi ed to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that to which Increase the separation between the equipment and receiver the receiver is connected
Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment CONFIGURATION The M4IN1Z-1 supports the Con guration command. Each unit can be con gured to operate slightly differently that how it works when it is rst installed. Using the Con guration command , the following can be con gured:
Temperature The reporting temperature parameters can be set to the consumers speci c needs, changing from Celsius (default) to FaHrenheit and the reporting threshold (default 1 C) Parameter 1 Parameter 2 Humidity Parameter 3 Light Parameter 4 Motion Sensor Parameter 5 Parameter 6 Size 1 bit 1 bit Size 1 bit Size 1 bit Size 1 bit Size 1 bit Value 0C 0x00 Default C (0x00) 1 (1C) Default 10%
Default 10%
F 0x01 1 - 50 (Setup from 0.1 C - 5 C Value 1 - 50 (Setup from 1% - 50%) Value 0.5 - 50 (Setup from 0 for OFF or 5% - 50%) Value 1 - 255 (unsigned decimal) Minutes
(default: 3 minutes) Value 1 - 7
(default: 4)
(Parameter 5) Re-trigger duration: User can change value from 1 to 255 minutes to setup the re-trigger time when there is no movement detected in the period of time. Default is 3 minutes.
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1=
most sensitive, 7 = most insensitive, default values = 4. 3 IMPLIED WARRANTY, Limitations THE DURATION OF ANY INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY. Some states do not allow the exclusion of limitation or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you speci c legal rights, and you may also have other legal rights which vary from State to State. Important !!!
Radio controls provide a reliable communications link and ll an important need in portable wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices.
As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users IC Notice This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. NOTICES Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the United States and other countries. WARRANTY What is Covered?
Nortek Security & Control (NS&C) warrants to consumers who purchase this product for personal, family or household purposes new from NS&C directly or from an authorized NS&C dealer, that the product will be free from defects in materials and workmanship for a period of (1) year from the date of purchase. This warranty only applies if the product is installed at a residence in the 50 United States or District of Columbia, and only at the site of the original installation. It is not transferable. This warranty is not extended to resellers. If a defect exists, NS&C will have you ship the defective part or product to us and we will, at our option, either repair or replace it. This warranty does not cover the cost of labor to remove a defective part or product or to reinstall any repaired or replacement part. This warranty does not cover defects or damages caused by improper handling, maintenance, storage, installation, removal or re-installation, misuse, non-factory authorized modi cation or alteration, use of incompatible accessories, electrical power problems or surges, impact by foreign objects, accident, re, acts of God, normal wear and tear or shipping damage other than a shipment from NS&C. Note that all NS&C products are designed to be installed, removed and serviced by trained individuals or professionals. Keep your original sales receipt as it will be required to obtain warranty service. This warranty shall not be extended or restarted upon receipt of any repaired or replacement part or product under this warranty. No person is authorized to extend or otherwise modify this warranty. How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at returns@nortek. com. Include your name, address, telephone number, the model number of your product, a copy of your original sales receipt, and a description of the problem. Unless we need to discuss the situation further with you, you will be emailed a Return Authorization Number and shipping instructions. If we need to discuss the situation further with you, we will call or email you. NS&C may require troubleshooting on installed product before a Return Authorization Number is issued. Anything shipped to us without a Return Authorization Number will be automatically returned unopened. You are responsible for the charges for shipment to us, unless you are a California resident Copyright 2016 Nortek Security & Control LLC 4 10012103X4