3 English OPERATINGINSTRUCTIONS
a safe place. The illustrations in this manual are provided as examples. Failure to follow the procedures described in this manual may lead to false results. Tableofcontents 1. Safety Instructions 2. Description 3. Use 4. Calibration and Warranty 5. Troubleshooting 6. Product Features 7. Recycling 23 25 26 30 31 33 36 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. NOTE: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the users authority to operate the equipment I H S L G N E 1.SafetyInstructions PRECAUTIONSFORUSE
Use the device at its operating temperature of between
+10C and +40C.
Use a new mouthpiece for each use. A used mouthpiece may trap alcohol and the device will display false results.
Blow into the nozzle only when the device indicates the
Never use the breathalyzer without a mouthpiece.
Do not insert any liquid, gaseous or solid substance into
food etc.).
Do not allow the device to be exposed to direct sunlight or place it close to a heat source.
Do not drop or subject the device to sudden impact.
If the device has exceeded its calibration date, you run
22
23
The results obtained are for information purposes only, have no legal value and therefore will not be considered as evidence in court or by law enforcement agencies. SAFETYINFORMATION
The OCIGO product is not a toy.
It should not be used by children under 3 years of age. Use by children over 3 years of age should always be supervised by an adult.
Do not leave OCIGO charging and on for more than 20 minutes.
instructions, the protection provided by the device may be compromised.
use 2.Description
I H S L G N E PRODUCTOVERVIEW OCIGO Breathalyzer 1 Mouthpiece
OLED display 2 3 4 5
BOXCONTENTS OCIGO breathalyzer test Storage box Storage box 3 mouthpieces Micro USB cable type B
+ Set of operating instructions
24
25 3.Use INITIALUSEANDCONFIGURATION
1 2 exhaled air 3 4 If you wish to change this factory setting, please refer to
STANDALONEMODE 1Turn on your OCIGO breathalyzer (1) by pressing the On button (3). 2Then follow the instructions on the screen. 3The device prompts you to insert a new mouthpiece
4
5Blowsteadilybutnottoohard,until the gauge is
6- If the measurement is between 0.00 mg/L and the legal threshold, the exact measurement is displayed for 10 seconds.
- If the measurement is between the legal threshold I H S L G N E
for 10 seconds, then alternately displays the exact
- If the measurement is greater than 0.50 mg/L, the
means that the device has detected residual alcohol in the mouth, and therefore does not display any measurement. 7Once the test is complete, the device proceeds to
beforehand. CONNECTEDMODE 1Download the OCIGO application from the App Store or Google Play. 2Enable Bluetooth on your smartphone. 3Turn on your OCIGO by pressing the Onbutton(3) 4Launch the OCIGO application. 5Accept the General Terms and Conditions of Use 26
27 6 which you can change your user information (name, driver category, language) and the measurement parameters (units of measurement, regulatory thresholds by selecting the country). 7Validate and accept the permissions (geolocation, Bluetooth, camera). 8Then follow the instructions on your smartphones screen by using the device in the same way as for standalone use. 9
USINGTHEMENU Access the OCIGO menu by pressing the
Pressoncefor:Batterylevel
Presstwicefor:
use. I H S L G N E Pressthreetimesfor:Bluetooth
RECHARGINGTHEBATTERY To recharge the OCIGO, connect the cable supplied in the box to the micro USB port (5) of the device, and then connect it to a power supply (see Technical Features). The total OCIGO recharging time is approximately 2.5 hours. For safety reasons, the device cannot be charged outside the 0 - 40C temperature range. A charge indicator will tell you if the device is charging correctly. 28
29 4.CalibrationandWarranty CALIBRATION
Each device must be calibrated annually. The calibration date appears when your OCIGO starts up.
The purpose of calibration is to verify the relevance of the results reported by the breathalyzer, by performing a series of tests under the supervision of an accredited laboratory.
OCIGO, the reliability and accuracy of the results are no longer assured. However, the device will continue to operate.
Calibration should only be carried out by competent and authorized persons. WARRANTY
Under the legal warranty of conformity, OLYTHE guarantees the product against any manufacturing defect that may occur during normal use for 2 (two) years from the date of delivery.
The warranty does not cover damage or defects resulting from use which is not in accordance with these instructions, or any repairs or dismantling carried out or
I H S L G N E CONTACTS
For any information regarding calibration, warranty or technical questions about your product, please contact
these instructions) 5.Troubleshooting
Invalidbreathmessageandvibratestwicewhen youblowintothedevice.
is also possible that you may have blown too hard. The application can guide you while you blow. Remember to attach a new mouthpiece beforehand to ensure the reliability of the new test.
WaitmessagewhenOCIGOsustainsasudden movement. In order to provide a correct measurement, the OCIGO
avoid violent jolts and sudden movements before blowing. OCIGOdoesnotrechargewhilepluggedin OCIGO can only be recharged when the ambient temperature is between 0C and +40C. Please wait until the temperature drops below 40C. 30
31 Messageremovemouthpieceappearsseveral timesinarow. If the mouthpiece has been inserted while the cleaning
remove the mouthpiece and resume its cleaning cycle
message is displayed. MessagesT<5CorT>45CfollowedbyOCIGO
OCIGO detects a temperature range below 5C or above
temperature is above 5C or below 45C before turning MessageT10C-40Cwhenstartingupthe OCIGO. The device detects a temperature range of between 5C and 10C or between 40C and 45C. You can perform a measurement, but it will not be reliable because it is outside the operating range. OCIGO can only operate correctly when the ambient temperature is between 10C and 40C. ThelevelsdisplayedbytheOCIGOseeminconsistent
- Wait 20 minutes after your last glass of alcohol or 5
32
OCIGO is probably experiencing a technical problem. Contact our technical support (see contact details on the
I H S L G N E 6.ProductFeatures TECHNICALFEATURES Measurementprinciple infrared spectroscopy technology
: 25 25 185 mm Weight: 60 g Measurementrange :
- Blood alcohol content (BAC) 0,00 to 2.39 g/L*
*Upper limit may vary depending on the country.
theapplication) :
Measurementaccuracy : Compliant with EN 16280
(chapter 7) Bluetoothversion : 4.0 Batterytype : 860mAh (Lithium Polymer) Batteryvoltage : 3.7 V NominalCurrent : 170 mA Electricalsupply :
- Micro USB (type B)
33
Max.RFpowertransfer :0dBM Compliance :CE - The CE Declaration of Conformity is available on request frm contact@olythe.com ENVIRONMENTALCONDITIONS Generaluse: Class B (Domestic) equipment Pollutionlevel(accordingtoIEC60664-1): 2 Use: from 10C to 40C Storage: at -10C to 45C Load: from 0C to 40C I H S L G N E ALCOHOLLIMITSINMAINEUROPEANCOUNTRIES
(indicativeinformationnotguaranteed) COUNTRY BACLimit(g/L)* BrAC(mg/L)**
Austria 0.50 0.25 Belgium 0.50 0.22 Bulgaria 0.50 0.25 Croatia 0.53 0.24 Cyprus 0.50 0.22 Czech Republic 0.00 0.00
0.53 0.25 Estonia 0.21 0.10 Finland 0.53 0.22 France0.50 0.25 Germany 0.53 0.25 Greece 0.50 0.25 Hungary 0.00 0.00 Ireland 0.50 0.22 Italy 0.50 0.25 Latvia 0.50 0.24 Lithuania 0.40 0.20 Luxembourg 0.50 0.25 Malta 0.50 0.22 Netherlands 0.50 0.22 Norway 0.21 0.10 Poland 0.20 0.10 Portugal 0.48 0.21 Romania 0.00 0.00
0.00 0.00 Slovenia 0.53 0.24 Spain 0.50 0.25 Sweden 0.21 0.10 34
35 I H S L G N E Switzerland 0.50 0.25 United Kingdom (England) 0.80 0.35 United Kingdom (Scotland) 0.50 0.22
*BAC: Blood Alcohol concentration = blood alcohol content
**BrAC: Breath Alcohol concentration = alcohol content in exhaled air (measured directly by the OCIGO). 7.Recycling This symbol indicates that electrical and electronic equipment is collected separately. Electrical and electronic
environment and health. Used electrical products must not be thrown away with household
recycling centres, charities, NGOs etc.
and human health due to hazardous substances that can be found in some electrical or electronic equipments 36
37