Dry Contact Input Transmitter DRY CONTACT INPUT 4.33 MHz GROUP CONTROL SEQUENCE MODE 1 1 2 AUTOMATE | Dry contact input transmitter enables most common mechanical switches or automation systems relays to control ARC motorized shades. It functions as a single channel transmitter and accepts dry contact input. Once a motor or group of motors are paired to the transmitter, it converts the dry contact inputs and sends ARC radio commands to trigger those motors to move upward/downward. FEATURES:
Interface between third party smart home systems and ARC motors Three dry contact inputs Wireless signal output ARC motor communication protocol Group Motor Control Four switch modes 12V or 24V power source compatible 8 1 0 2 _ Y L U J _ 0
. 1 v _ C 1
-
M C D
-
F R T M I CONTENTS TECHNICAL DATA / PACK CONTENTS SAFETY INSTALLATION 1 2 3 3.1 Overview 3.2 Wire Diagram 4 5 SETTING SWITCH MODE ADDING OR DELETING A TRANSMITTER & CREATING A GROUP OF CHANNELS 5.1 Using motor P1 button 5.2 Using a pre-existing controller 6 SWITCH MODE OPERATION 6.1 Operation of Normal Switch Mode 6.2 Operation of Pulse Switch Mode 6.3 Operation of Mechanical Switch Mode 6.4 Operation of Sequence Switch Mode 6.5 Operation of Favorite Position 7 TROUBLESHOOTING NOTES 3 4 5 5 5 6 7 7 7 8 8 9 10 11 12 13 14 2 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA 1 TECHNICAL DATA / PACK CONTENTS TECHNICAL SPECIFICATIONS 12V Power Input Voltage:
24V Power Input Voltage:
Radio Frequency Transmitting Power:
Ambient Operating Temperature:
Transmission Distance:
8V ~ 16V 16V ~ 26V 433.92 MHz 10 milliwatt
-10C ~ 50C 14F ~ 122F up to 200m (open space) up to 656 (open space) Dry Contract Input Duration
>0.25 seconds PACK CONTENTS 1x contact closure box 1 x instructions DIMENSIONS
[2 1/2"]
65mm
[1 3/4"]
45mm
[7/8"]
23mm PRODUCT SPECIFICATION SHEET ITEM DESCRIPTION:
Inspection Drawing ITEM CODE:
3 | Automate Programming Instructions | MTRF-DCIM-1C MTRF-DCIM-1C www.rolleaseacmeda.com
[1 1/2"]
37mm C ROLLEASE ACMEDA SCALE:2:1 DRAWN:
20 MAR 2018 PROPRIETARY & CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ROLLEASE ACMEDA. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ROLLEASE ACMEDA IS PROHIBITED. ROLLEASE ACMEDA IN "MM"
DIMENSIONS SIZE: A3 REV. 01 1 STATIC TITLE 2 SAFETY WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturers liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Do not expose to moisture or extreme temperatures. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Follow installation instructions. For use with motorized shading devices. Keep away from children. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Keep clear when in operation. CAUTION Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of R&TT EC Directive 1999/5/EC. This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning th equipment off an on, the user is encouraged to try correct the interference by one or more of the following measures:
Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 5005833 4 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA 3 FUNCTIONAL OVERVIEW 3.1 Overview
[2 1/2"]
65mm
[1 3/4"]
STOP 45mm DOWN UP COMMON SET LED GROUND CONTACT POSITIVE CONTACT 12V POSITIVE CONTACT 24V 3.2 Wiring Diagram
[7/8"]
23mm
[1 3/4"]
45mm
[1 1/2"]
37mm
+24V
+12V C ROLLEASE ACMEDA SCALE:2:1 DRAWN:
[7/8"]
20 MAR 2018 23mm GROUND www.rolleaseacmeda.com PROPRIETARY & CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ROLLEASE ACMEDA. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ROLLEASE ACMEDA IS PROHIBITED. NOTE: Only one positive power point, +12V or +24V, is needed. DIMENSIONS IN "MM"
SIZE: A3 REV. 01 ROLLEASE ACMEDA Automate Programming Instructions | MTRF-DCIM-1C | 5 4 SETTING SWITCH MODE
[2 1/2"]
65mm IMPORTANT The SET button is utilized to choose the working mode of the dry contact input transmitter as described below:
[1 3/4"]
45mm Continuously hold SET button and release when the desirable switch mode is achieved. NORMAL SWITCH MODE Approx. LED Response LED Response FLASH x2 FLASH x1 PRODUCT SPECIFICATION SHEET PULSE SWITCH MODE ITEM DESCRIPTION:
Inspection Drawing ITEM CODE:
MTRF-DCIM-1C LED flashing indicates switch mode type.
[1 1/2"]
37mm RELEASE SET BUTTON
[7/8"]
23mm C ROLLEASE ACMEDA SCALE:2:1 DRAWN:
20 MAR 2018 www.rolleaseacmeda.com PROPRIETARY & CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ROLLEASE ACMEDA. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF ROLLEASE ACMEDA IS PROHIBITED. DIMENSIONS IN "MM"
Approx. Approx. RELEASE SET BUTTON LED Response LED Response LED Response FLASH x2 FLASH x1 FLASH x1 MECHANICAL SWITCH MODE Approx. Approx. Approx. LED Response LED Response LED Response LED Response FLASH x2 FLASH x1 FLASH x1 FLASH x1 RELEASE SET BUTTON SEQUENCE SWITCH MODE Approx. Approx. Approx. Approx. LED Response LED Response LED Response LED Response LED Response FLASH x2 FLASH x1 FLASH x1 FLASH x1 FLASH x1 RELEASE SET BUTTON 6 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA 5 ADDING OR DELETING TRANSMITTER & CREATING GROUP CHANNELS IMPORTANT Multiple motors can be paired to the dry contact input transmitter for group control. Their limit settings and favorite positions should be individually adjusted by a single channel remote, which is only paired to one of those motors Confirm that motor limits and favorite position are already set for each individual motor. Ensure that each motor you want to group is also assigned to a channel by itself or another remote.
[2 1/2"]
65mm 5.1 Using Motor P1 Button NOTE: This is not applicable in mechanical switching mode. Hold P1 button on motor head. Hold STOP on controller to add or remove.
[1 3/4"]
45mm Motor Response RELEASE P1 Motor Response Approx.
[7/8"]
23mm 5.2 Using a preexisting Controller
[2 1/2"]
65mm PRODUCT SPECIFICATION SHEET ITEM DESCRIPTION:
Inspection Drawing Press P2 on existing controller. Pres P2 on existing controller. ITEM CODE:
MTRF-DCIM-1C Press and release SET button on new transmitter.
[1 3/4"]
45mm
[7/8"]
23mm Motor Response Motor Response Motor Response ROLLEASE ACMEDA Automate Programming Instructions | MTRF-DCIM-1C | 7 PRODUCT SPECIFICATION SHEET ITEM DESCRIPTION:
Inspection Drawing 6 SWITCH MODE OPERATION Prior to selecting a switch mode, the upper and bottom limits of any ARC motors must be set. A single or combination of three dry contact inputs can operate the paired ARC motors. 6.1 Operation of Normal Switch Mode NOTE: In this mode, the transmitter can implement all the ARC remote functions. The P2 button of the remote is described as the SET button in the transmitter. Please refer to the motor instructions for functions such as setting/adjusting limits, setting a favorite position, toggling tilt/roller mode etc. MOVE UP UNDER ROLLER MOTOR MODE STOP DOWN UP COMMON MOVE DOWN UNDER ROLLER MOTOR MODE STOP DOWN UP COMMON STOP UNDER ROLLER MOTOR MODE STOP DOWN UP COMMON CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT 8 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA 6.2 Operation of Pulse Switch Mode NOTE: The time interval of each pulse should be in the range of 0.25 ~ 2.0 seconds. The motor rotation can be stopped by using the STOP button or the UP & DOWN together in the roller motor mode. In the tilt mode, each closing pulse triggers the motor to move one small step but a pulse longer than 2 seconds can trigger continuous movement of the motor. MOVE UP/DOWN, STOP IN ROLLER MOTOR MODE STOP DOWN UP COMMON MOVE UP IN TILT MOTOR MODE STOP DOWN UP COMMON MOVE DOWN IN TILT MOTOR MODE STOP DOWN UP COMMON CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT ROLLEASE ACMEDA Automate Programming Instructions | MTRF-DCIM-1C | 9 6.3 Operation of Mechanical Switch Mode NOTE: Closing the UP/DOWN dry contacts keeps the motor rotating, opening the dry contacts immediately stops the rotation in the roller motor mode. In the tilt motor mode, each UP/DOWN closing pulse, whatever the pulse duration, triggers the motor to move one UP/DOWN step. MOVE UP IN THE ROLLER MOTOR MODE STOP DOWN UP COMMON MOVE DOWN IN THE ROLLER MOTOR MODE STOP DOWN UP COMMON OPERATION IN TILT MOTOR MODE STOP DOWN UP COMMON CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT 10 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA 6.4 Operation of Sequence Switch Mode NOTE: The closing/releasing of the UP pin alternatively triggers the upward movement or the stopping of the paired motor. The closing of the DOWN pin alternatively triggers the downward movement or the stopping of the paired motor. MOVE UP IN THE ROLLER MOTOR MODE STOP DOWN UP COMMON MOVE DOWN IN THE ROLLER MOTOR MODE STOP DOWN UP COMMON CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT LOWER LIMIT ROLLEASE ACMEDA Automate Programming Instructions | MTRF-DCIM-1C | 11 6.5 Operation of Favorite Position NOTE: Closing the STOP pin for more than 5 seconds can activate the motor to move to the preset favorite position under Normal, Pulse & Sequence Mode. FAVORITE POSITION STOP DOWN UP COMMON CLOSED OPEN CLOSED OPEN CLOSED OPEN UPPER LIMIT FAVORITE LOWER LIMIT 12 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA 7 TROUBLE SHOOTING Problem Cause Switch power supply is not connected Radio interference / Shielding Motor is not responding Receiver distance is too far from switch Power failure Incorrect motor wiring Cannot set limits on a single motor (multiple motors respond) Transmitter has group control function set and drives all the paired motors together Motor will not go down after setting the top limit Top limit was set using the down and stop buttons Remedy Check power source and connections. Ensure switch is positioned away from metal objects and that the antenna on motors are kept straight and away from metal. Move switch to a closer position. Check power supply to motor is connected and active (non-battery motors). Check motor wiring is connected correctly (refer to motor installation instructions). Use an ARC remote to individually adjust motor limits. Use P1 motor button to set other motors in group into Sleep mode. SYSTEM BEST PRACTICE - Provide an extra 15 channel switch or remote in you multi motor projects to provide individual control for each motor for programming/
configuration purposes. Reset the motor and begin programming sequence again. Remember that upper limit is to be set using the up and stop and the down limit is set using the down and stop. ROLLEASE ACMEDA Automate Programming Instructions | MTRF-DCIM-1C | 13 NOTES 14 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA NOTES 15 | Automate Programming Instructions | MTRF-DCIM-1C ROLLEASE ACMEDA ROLLEASE ACMEDA | AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047 T +61 3 9355 0100 | F +61 3 9355 0110 ROLLEASE ACMEDA | USA 750 East Main Street 7th Floor, Stamford, CT 06902 6320 T +1 203 964 1573 | F +1 203 964 0513 ROLLEASE ACMEDA | EUROPE Via Conca Del Naviglio 18, Milan
(Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317 info@rolleaseacmeda.com rolleaseacmeda.com 16 | Automate Programming Instructions | MTRF-DCIM-1C