AUTOMATE Paradigm Remote Control LEVEL CONTROL TOUCH SENSITIVE 433 MHz AUTOMATE | Paradigm remotes feature a contemporary design with touch sensivite controls. Available in single and fifteen channel models, Paradigm remotes are compatible with all ARC motors. FEATURES:
Available in single channel & Fifteen Channel. Touch sensitive buttons. Levelling control (15 channel remote). LCD display (15 Channel remote). Hide unused channel function. Slim Magnetic wall mount. 6 1 0 2 T P E S 2
. 1 V M E R
-
F R T M
-
R T S N I CONTENTS TECHNICAL DATA / PACK CONTENTS SAFETY INSTALLATION 1 2 3 3.1 Wall mount holder 3.2 Remote battery 4 FUNCTIONAL OVERVIEW 4.1 Buttons 4.2 Levelling control 4.3 Selecting a channel - (multi channel remote) 4.4 Group control using CH 0 5 PROGRAMMING 5.1 Protocol selection 5.2 Hide unused channels 5.3 Disable limit setting function of remote 6 ADDING OR REMOVING CONTROLLERS & CREATING GROUP CHANNELS 6.1 Using Motor P1 Button 6.2 Using a pre-existing Controller 7 TROUBLESHOOTING 3 4 5 5 5 6 6 6 7 7 8 8 9 9 10 10 10 11 2 | Automate Programming Instructions | Paradigm Remotes ROLLEASE ACMEDA 1 TECHNICAL DATA / PACK CONTENTS TECHNICAL SPECIFICATIONS Voltage:
Frequency:
Transmitting Power:
Ambient Operating Temperature:
3V (CR2450) 433.92 MHz 10 milliwatt
-10C -50C Transmission Distance:
up to 200 meters (open space) PACK CONTENTS 1 x remote (Single or Fifteen Channel) 1 x magnetic holder inc. wall fixing screws 1 x Instruction manual 1 x 3V - CR2450 battery ROLLEASE ACMEDA Automate Programming Instructions | Paradigm Remotes | 3 2 SAFETY WARNING: Important safety instructions to be read before installation and use. Incorrect installation or use can lead to serious injury and will void manufacturers liability and warranty. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Do not expose to water, moisture, humid and damp environments or extreme temperatures. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. Follow installation instructions. For use with motorized shading devices. Keep away from children. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Keep clear when in operation. Replace battery with correctly specified type. Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of R&TT EC Directive 1999/5/EC This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which Can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 4 | Automate Programming Instructions | Paradigm Remotes ROLLEASE ACMEDA 3 INSTALLATION 3.1 Wall mount holder Remove cover from base by prying with flat head screwdriver. Use supplied fasteners and anchors to attach the base to wall. 3.2 Remote battery Replace cover by pressing snap latches into place. Remove cover from remote press gently in and down to disengage cover. Install battery with positive (+) side facing up. Slide to remove. ROLLEASE ACMEDA Automate Programming Instructions | Paradigm Remotes | 5 4 FUNCTIONAL OVERVIEW 4.1 Buttons LEVEL CONTROL UP STOP DOWN CHANNEL SETTING (P2) 4.2 Levelling control The levelling control bar can be used to visualize and accurately set your preferred shade position. When used to control a group of shades, they will all perfectly align to the same position. 6 | Automate Programming Instructions | Paradigm Remotes ROLLEASE ACMEDA 4.3 Selecting a channel - (multi channel remote) Hold CH button. Within 4 seconds press UP or DOWN to select desired channel . Press CH or STOP to confirm Response LCD screen will begin to flash IMPORTANT If no button is pressed within 4 seconds, the channel selection will automatically be confirmed 4.4 Group control using CH 0 Channel "0" is pre-set to controll ALL shades paired within your multi-channel remote. To create a customized group channel ref to section 6 ROLLEASE ACMEDA Automate Programming Instructions | Paradigm Remotes | 7 5 PROGRAMMING IMPORTANT Please refer to the the relevant documentation of your motor model for instructions on adjusting motor settings. 5.1 Protocol selection This device can be configured to operate Acmeda line EL motors. (The default mode is ARC protocol). To toggle between ARC & EL modes follow the following steps. HOLD P2 whilst inserting battery For 15 CH For 1 CH Screen flashes X 5 Screen flashes 1 = ARC Mode Screen flashes 2 = EL Mode 1 Flash = ARC Mode 2 Flashes = EL Mode 8 | Automate Programming Instructions | Paradigm Remotes ROLLEASE ACMEDA 5.2 Hide unused channels Your multi channel remote can be configured to have anywhere between 1 or 15 visible channels. Inactive channels will not be visible when scrolling through the CH selection. Hold STOP and CH Continue holding CH and select required channel qty by pressing UP or DOWN Press STOP to confirm Response Channel 15 flashes Response Flashing stops 5.3 Disable limit setting function of remote IMPORTANT This mode is intended to be used after all shade programming is completed. User Mode will prevent accidental or unintended changing of limits. To switch modes hold right button for 5 Seconds 15 CH 1 CH Pressing the right button for 1 second or less will display the current mode Response Response LCD displays L when locked LED solid on when locked LCD displays U when unlocked LED blinking when unlocked It is still possible to add or delete channels and perform P2 functions, while the lock function is enabled. ROLLEASE ACMEDA Automate Programming Instructions | Paradigm Remotes | 9 6 ADDING OR REMOVING CONTROLLERS & CREATING GROUP CHANNELS 6.1 Using Motor P1 Button Hold P1 button on motor head. Hold STOP on controller to add or remove. Motor Response Motor Response 6.2 Using a pre-existing Controller Press P2 on existing controller. Press P2 on existing controller. Press P2 on new controller. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor. 10 | Automate Programming Instructions | Paradigm Remotes ROLLEASE ACMEDA 7 TROUBLESHOOTING Problem Cause Remedy Remote battery is discharged Replace battery Battery is inserted incorrectly Check battery polarity Radio interference / Shielding Ensure remote is positioned away from metal objects and that aerial on motor or reciever is kept straight and away from metal. Motor is not responding Receiver distance is too far from remote Move remote to a closer position Power failure Incorrect wiring Cannot set limits on a single motor (multiple motors respond) Using Group channels to adjust motor limits Check power supply to motor is connected and active Check wiring is connected correctly
(refer to motor installation instructions) Always reserve an individual channel for programming functions. SYSTEM BEST PRACTICE - Provide an extra 15 channel remote in your multi motor projects, that provides individual control for each motor for programming purposes. ROLLEASE ACMEDA Automate Programming Instructions | Paradigm Remotes | 11 Western Australia Branch Unit 1, 41 Mulgul Road, Malaga WA 6090 T +61 8 9248 5571 | F +61 8 9248 5572 Queensland Branch Unit 2/62 Borthwick Avenue, Murarrie QLD 4172 ROLLEASE ACMEDA AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047 T +61 3 9355 0100 | F +61 3 9355 0110 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford, CT 06902 6320 T +1 203 964 1573 | F +1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18, Milan
(Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317 info@rolleaseacmeda.com rolleaseacmeda.com 12 | Automate Programming Instructions | Paradigm Remotes