AY-B8650 Figure 1: AY-B8650 MHz Anti-Vandal Fingerprint and 13.56 MIFARE RFID Reader User Manual 1. Introduction The AY-B8650 series are biometric fingerprint and RFID card reader with a compact design, which is suitable for installing on a door frame. The USB power supply and debug make operations simple. The reader IP65 certified for outdoor use. Using AxTraxNG, you can register and delete users (see the AxTraxNG Software Installation and User Manual). Alternatively, you can use master cards to register and delete users while in an offline state. The standard Wiegand output seamlessly connects to the third-party access controllers. The reader comes in two models:
2. Installation 2.1 Mounting 1. Using the back panel as a guide, drill two holes for mounting AY-B8650 13.56 MHz MIFARE card reader the back plate onto the surface (Figure 2). Wiring 2.2 To connect the unit as a reader to an access control unit:
1. Select the appropriate connections according to Table 1. Figure 2: Wall Mounting Table 1: Wiring the Unit as a Reader to a Control Panel Function Cable Color Description Insert a suitable wall plug into each screw hole. 2. 3. Drill a 10-mm (7/16) hole for the cable. 4. Screw the back plate onto the wall. 5. Connect the reader to the controller (see Section 2.2). A linear type power supply is recommended. 6. Attach the reader to the back plate and secure the reader to the back plate with the provided security screw and tools. Power Wiegand Output Red Black Tamper Alarm Brown Orange Green White Blue Black Light brown Light Blue 12 VDC GND Tamper Tamper Wiegand DATA0 Output Wiegand DATA1 Output Wiegand switch GND RS-485B/GND RS-485A/pulse signal (3.3 V) 2. Prepare the controller cable by cutting its jacket back about Pulse Signal 3 cm (1") and strip the insulation from the wires about 1.3 cm
("). 3. Splice the readers pigtail wires to the corresponding controller wires and cover each joint with insulating tape. 4. Trim and insulate the ends of all unused conductors individually. Do not short any unused wires together. The individual wires from the reader are color coded according the Wiegand standard. When using a separate power supply for the reader, this supply and that of the controller must have a common ground. The readers cable shield wire should be preferably attached to an earth ground, or a signal ground connection at the panel, or the power supply end of the cable. This configuration is best for shielding the reader cable from external interference. 1 3. Operation 3.1 Register a management card (Enroll and Delete) as shown in Figure 3. Registering a Management Card Figure 3: Registering Management Card 3.3.3 Registering a Fingerprint and Card Register a fingerprint and card as shown in Figure 7. Figure 7: Registering a Fingerprint and Card 3.2 Resetting a Management Card (Enroll and Delete) To reset a management card, press and hold the function button located inside the back cover of the reader until you hear beeps
(Figure 4). Figure 4: Function Button If the card and/or fingerprint have been already registered, the red LED flashes and there are 2 long beeps. 3.3.4 Registering Two Fingerprints and a Card Register two fingerprints and a card as shown in Figure 8. Figure 8: Registering Two Fingerprints and a Card Registering a User 3.3 There are three ways to register a user: fingerprint, card, card+fingerprint. See Section 4 about how to properly place your finger on the reader. 3.3.1 Register a fingerprint as shown in Figure 5. Registering a Fingerprint Figure 5: Registering a Fingerprint 3.4 3.4.1 Delete a fingerprint from the reader as shown in Figure 9. Deleting Users Deleting a Fingerprint Figure 9: Deleting a Fingerprint If the fingerprint does not exist in the system, the red LED flashes and there is a long beep. 3.4.2 Delete a fingerprint from the reader as shown in Figure 10. Deleting a Card Figure 10: Deleting a Card If the finger has been already registered, the red LED flashes and there are 2 long beeps. 3.3.2 Registering Two Fingerprints Register two fingerprints as shown in Figure 6. Figure 6: Registering Two Fingerprints If the card does not exist in the system, the red LED flashes and there is a long beep. 3.4.3 Delete all users from the reader as shown in Figure 11. Deleting all Users Figure 11: Deleting all Users 2 4. Instructions for Placing Finger Correct Method: Straighten your finger and then place it on the sensor, ensuring the finger is down flat and covers the entire sensor window. Always place finger in the center of the sensor. Incorrect Method:
Make sure you cover the entire sensor surface with as much of your finger as possible. DO NOT move your finger before the backlights of the sensor turns off. DO NOT place finger away from the center of the sensor window DO NOT place finger at an angle. DO NOT take off finger during the fingerprint verification process. DO NOT use just your fingertip. DO NOT slide your finger during the fingerprint verification process. Figure 12: Reader Layout 5. Technical Specifications Fingerprint Sensor RFID Card Reader 500 DPI Optical Sensor AY-B8650 13.56 MHz User Capacity Fingerprint Capacity Card Capacity Log Capacity Verification Speed Card Read Range Identification Mode Network Port Wiegand Protocol Voice and Interface Operating Voltage Work Current Operating Temperature Range Humidity Range Size (W x H x D) Certificate 7000 7000 7000 100,000
< 1 Second (1:N) 20 to 80 mm (0.8 to 3.1 in.) Fingerprint/Card TCP/IP Wiegand 26-Bit Multi-color LEDs and buzzer 12 VDC 150 mA
-20C to 60C 10% to 95% (non-condensing) 50 x 124 x 34.5 mm (1.97 x 4.9 x 1.4 in.) FCC, CE, RoHS 6. Usage Notice Do not scratch the surface of the optical fingerprint sensor with any sharp object such as a small knife or a pen. Humidity, dust, and direct light can affect the terminals performance. Do not clean the surface of the optical fingerprint sensor with organic material such as alcohol or gasoline. To clean the surface, apply a piece of one-sided adhesive tape to the sensor and then remove. 3 Declaration of Conformity FCC ID = GCD-B8650 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from Increase the separation between the equipment and receiver. that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radio Equipment Directive (RED) Rosslare hereby declares that the AY-B8650 is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU. RoHS Directive Under our sole responsibility that the following labeled AY-B8650 is tested to conform to the Restriction of Hazardous Substances (RoHS) directive 2011/65/EU in electrical and electronic equipment. Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them. CERT ISO 9001 ISO 14001 4 0706-0960676+00 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement. Company: U-tec Group Inc. Address: 44292 Fremont Blvd, Fremont, CA 94538 Name: Kevin Zhu Position: Product Manager Tel: 844-439-8832 Fax: 844-439-8832 Email: kevin@u-tec.com Web: www.u-tec.com