submitted | available | document details (if available) | source link |
---|---|---|---|
November 08 2017 | November 08 2017 |
various | Users Manual | Users Manual | 513.40 KiB | November 08 2017 |
Package Contents:
- RTX8162EX
- Battery
- Belt clip
- Pull cord
- This Reference Guide Quick Reference Guide Front View To use the RTX8162EX for the first time:
- Open the battery lid;
- Remove the plastic strip from the battery contacts
- Close the battery lid;
- Place the RTX8162EX on the chargedr to fully charge the battery Main Menu Items Contacts Central Directory Calls Top Line Icons Settings Calendar Accessories Messaging Signal Strength Battery Status Silenced Locked Ring Pull Cord Message Voice Mail Alarm Set Missed Call Caller Filter USB GETTING STARTED Turning the RTX8162 Ex on and off for a few seconds. Press and hold Activating your phone When the display of your phone is dark, press any key to activate your phone (phone in Idlemode). Lock/Unlock your phone In Idle mode press phone. To unlock your phone press Make a call In Idlemode:
(toggle function) or press Key Lock on the side of the and then
(toggle function). and then 1. Press 2. Press 3. Type the number you want to reach and then press 4. Use a speed dial key (
5. Press soft key OR and then type the number you want to reach. and then type the number you want to reach (speakerphone call) OR OR OR
, select the required contact and press soft key or or or
,
)
, or
. Answering an incoming call or, for speakerphone call, Press End a call
. Press
. ake an enq ring a call, gle betwe quiry call
, press and dial t en the two o parties. ange the v ring a call, volume
, press Vo he numbe er of the pa t Press to transfer arty you w r the call. want to co nsult. Pres ss to olume Up p or Volu ume Dow wn on the e side of th he phone. e the Spea ring a call, aker phon ne
, press
; to de-ac ctivate: pr ress aga ain. ute the mic ss the sof crophone ft key during a c
. To turn call the micro ophone on again, pre ess the so oft key
. ute the mic Idlemode te: You ma crophone
, press an ay need to during a c d hold o enter yo call rite and se end a text message for a few ur voicem w seconds ail numbe s. er in the ha andset set ttings first t. Idlemode 1. Press s 2. Use th en press so uired dest ntsuccessfu
, press soft key e navigati oft key tination(s) ully.
, use the
, then on keys to
, selec
). When navigatio n enter the o select a ct the type message s n keys to e text of y stored dra e of the me sent is gi select your messa aft messag essage (no ven in the ss the sof age. ess soft ke ge and pre urgent) an ormal or u e display y your messa and pre ft key OR ey
. d choose t age has be the een signing a Idlemode d press sof scroll to th contact to
, press sof ft key he appropr o a speed d dialling ke ey
,
, select th ft key e contact a e
. Choose and press riate numb ber (2..9) and press you want soft key s soft key to assign
. Use
. a speed d e the navi y dialling key gation key ys ake a shor Idlemode navigatio vigation ke tcut
, press on keys to eys or func e handset gister the Idlemode
, press navigatio on keys to t
(Regis ys to selec quested re ter the req it for the r registratio ing the me Idlemode uired men osen menu go back o enu
, press nu, menu t u or menu ne step in
, use the navigatio
(S select Shortcuts) s. ction keys n keys to
). Now you select and press u can assi gn a funct s soft key tion to one e of the n keys to
, use the navigatio ivity) and select
(Connecti t key ster) and press soft informatio on (contac gistration on to be co ompleted. select and press press soft t key s soft key
. Use th
. U he navigati ct your Sy ystem Adm ministrator for this). to access tab and m item/tab. the menu s the main menu item. Other sof u or leave menu. Us Use soft ft keys ma altogethe se the nav key ay provide r, press to the eys to go t vigation ke
) to se elect the s
( or press additiona al options. se
. U se ion Ma Dur tog Ch Dur Us Dur Mu Pre Mu In I Not Wr In I The req sen Ass In I and to s Ma In I the nav Re In I the key Ent Wa Us In I req cho To Setting
-
-
Display
-
-
-
-
Calls
-
-
-
-
-
-
-
s (continued) Feedback Key Conf Cove Cha Noise Red Sound nd firmation Sou erage Warning g rger Warning duction er Wallpape creen Startup Sc ve Power Sa Charger B Backlight Units Mode Answer M ter Caller Fil Emergen ncy Call Number r Message e SOS Key y Man Dow wn d Pull Cor l Number Voicemail Silent Cha arging all Time Missed Ca Connecti ivity
-
-
-
-
Register er Deregiste Select Ne etwork Bluetooth Enabled
/Disabled Search f for Devices Devices Paired D our appointme ents 5. 6. 7. Calendar Manage yo Accessories s s Alarms ator Calcula Stopwa atch Messaging Drafts Inbox Sent Messag Settings ges ntact by name e enu list Me 1. 2. 3. 4. Contacts List o Central Di Selec Calls of contacts irectory ct required con All Ca Answe Dialled Missed lls ered Calls d Calls d Calls
-
-
-
Settings Gener ral Settings Silent Time & Date Language
(Su upported: Eng nch, Italian, D Fre Tur rkish, Polish, N S Shortcuts (for LED Signal
-
-
Red LE Green Yellow Blue L ED LED w LED LED lish, Spanish, Dutch, Danish Norwegian, Gr the navigatio German,
, Swedish, reek & Russian on keys) n)
-
Security s Lock matic Key Lock k ge PIN Password e Phone Autom Chang Proxy Handset Nam
-
RFID
-
Reset Setting
-
S Status
-
ounds Silent Sounds ds Normal & So l Incoming Call
-
Volume Ring External/Inter Ring Grou up Ring rcom Ring Inter rgency Ring Eme Ring Arb. R Incre easing Ring rnal/Unknown n rator Vibr tifications Message Not fication Volum Notif ication Notif N Normal/Urgen easing Notifica Incre Vibra ator me A Alerts t/Emergency ation
-
-
olume Alert Vo Alert M Melody Increas sing Alert r Vibrato Additional Information for RTX8162 EX Regulatory information ATEX compliance information The RTX8162 EX complies with:
IEC/EN60079-0 and IEC/EN60079-11 with marking I M2 Ex ib I Mb II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135C Db
-10C ~ +50C IP65 Um = 5.25VDC CE0035 Presafe 17 ATEX 9520 X IECEx PRE 17.0011X The symbol X placed after the certification number indicates that during the use of the handsets the following conditions shall be met:
1. Do not sink the device in oil or hydraulic fluid 2. Protect your device from aggressive liquids and vapors 3. In the case of suspected damage, do not use the device in hazardous zone Handset Product Markings The RTX8162 ExDECT handset is a powerful communication tool and with itsEx design aimed to be used in hazardous area. The RTX8162 ExDECT handset is certified with the protection level High protection for use in zone 1 & 2 (Gas), in zone 21 & 22 (Gas) and in De-energized Ex atmosphere (Mining). The following Handset product markings will apply for Europe and EFTA. Important safety information Only use batteries marked withRTX8162 EX Do not use any battery WITHOUT marked RTX8162 EX Since this may present a risk of leakage, fire, explosion or other hazardous situation. Do not replace battery in hazardous area*
For battery replacement or removal, please do it outside hazardous area. After replacement of battery outside hazardous area, make sure the battery knob on battery has correctly and completely locked into the handset before going into hazardous area. Never disassemble, customize or short-circuit batteries Charge the battery or handset only outside of the hazardous areaand only in combination with the Gx66/I766 EnhDesktop ChargerwithGx66 AC Adapter Europlugor Gx66 AC Adapter Multi Regionor with the Gx66/I766 Enh Multi Charger Rack with Gx66 AC Adapter -Multi Charger Rack. Plug the Gx66 AC Adapter Europlug, Gx66 AC Adapter Multi Regionor the Gx66 AC Adapter -Multi Charger Rackin a wall outlet socket near the equipment for easy access/removal of the AC/DC adaptor.
*For more information or enquiries on hazardous area, please contact and consult your supplier or the local authorities for proper use of the product. Important battery information This product uses rechargeable Lithium-lon batteries (Cell model no.: LP553450SI - Li-ion 3.7V 1100mAh 4.2Wh). RTX8162 EX Only use batteries that come with the handset or dedicated spare batteries marked with RTX816x Ex Battery Pack.
- Do not use any other type, since this may present a risk of leakage, fire, explosion or other hazardous situation.
- Never disassemble, customize or short-circuit batteries.
- Do not place battery in fire or heat the battery.
- Charge the battery or handset outside hazardous area* and only in combination with the Gx66/I766 Enh Desktop Charger with Gx66 AC Adapter Europlug or Gx66 AC Adapter Multi Region or with the Gx66/I766 Enh Multi Charger Rack with Gx66 AC Adapter -Multi Charger Rack.
*For more information or enquiries on hazardous area, please contact and consult your supplier or the local authorities for proper use of the product. Sensitive Electronic Equipment Any radio-based equipment can potentially cause interference with other equipment and can be interfered from other equipment. This also applies for DECT equipment. However due to the very low transmission power level the chances for interference are very small. Research proves that operational DECT phones normally dont influence electronic equipment however some precautions must be taken into account for sensitive electronic equipment e.g. sensitive laboratory equipment. When DECT phones operate in straight nearness of sensitive electronic equipment incidental influence can appear. You are advised not to place the DECT phone on or close (less than 10cm) to this kind of equipment, even in standby mode. Please also use the other documentation supplied with the various parts of your telephone system. Product disposal information For countries in the European Union Be sure to dispose of these products as well as its packing material in an environmentally compatible way. Electrical equipment, including the battery, should not be disposed of as municipal waste. These products should be taken to a designated facility where the best available treatment, recovery and recycling techniques are available. At www.nec-enterprise.com/About-NEC/Environment/Green-policy-148 you can find information about separate disposal and environmentally sound recycling For countries outside the European Union Disposal of electrical and electronic products in countries outside the European Union should be done in line with the local regulations. If no arrangement has been made with your supplier, please contact the local authorities for further information Battery disposal information Defect or exhausted batteries should never be disposed of as municipal waste. Return old batteries to the battery supplier, a licensed battery dealer or a designated collection facility. Do not incinerate batteries. Original Manufacturer: RTX Hong Kong Ltd. 8/F Corporation Square, 8 Lam Lok Street, Kowloon Bay, Hong Kong Model: RTX8162 EX SAFETY AND REGULATORY INSTRUCTIONS Alcatel-Lucent 8262EX DECT Handset English Safety Instructions This approved DECT telephone is intended to be used for industrial applications in hazardous atmospheres of up to zone 2 (gas, vapors and mists) with an Alcatel-Lucent PBX. The following conditions must be respected, notably concerning the use of radioelectric frequencies:
Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user's authority tooperate the equipment. To limit the risk of interference, people with pacemakers must keep the wireless telephone away from their equipment (minimum distance of15 cm/6 inches). It is recommended to follow the standard acceptance procedures before using this equipment in human safety critical areas
(hospitals...). DECT equipment can only be used to establish links between fixed points if these links are temporary. The conditions of access to a DECT equipment telepoint network shall be stipulated by contract with the operator of the authorized telepointnetwork concerned. Switch off the telephone before changing the battery. You must not switch on or use your telephone near gas or inflammable liquids. The handset includes magnetic elements that may attract sharp metallic objects. CAUTION:There is a danger of explosion if the battery is replaced incorrectly. Use only recommended battery RTX816x EX Battery Pack (3BN67361AA, Cell model no.: LP553450SI - Li-ion 3.7V 1100mAh 4.2Wh). Be sure to dispose of these products as well as its packing material in an environmentally compatible way. Electrical equipment, including the battery, should not be disposed of as municipal waste. These products should be taken to a designated facility where the best available treatment, recovery and recycling techniques are available. The mains power socket used must be close to the charger/holder and easily accessible, so that it can be used as an 'on/off'
facility. Charge the battery for about 6 hours before initial use. The 8262 DECT Handset desktop Dual charger (3BN67346AA), is dedicated for 8262 EXDECTHandsets(3BN67345AA) and needs thefollowing Power Supply Units:
PSU Europe (3BN67335AA)
- TenPao (Model S005AYV0500100) efficiency level VI (rating I/P:AC 100-240V, 0.2A; O/P: DC 5V, 1A).
- Friwo FW7713/XX efficiency level V (rating I/P:AC 100-240V, 150mA; O/P: DC 5V, 1A). PSU WW (3BN67336AA)
- TenPao (Model S008ACM0500100 with UK,US,AUS plugs) efficiency level VI (rating I/P:AC 100-240V, 0.3A; O/P: DC 5V, 1A).
- Friwo FW7712 - efficiency level V (rating I/P:AC 100-240V, 125mA; O/P: DC 5V, 0.9A). The 8262 DECT Handset Rack Charger (3BN67351AA) will use a dedicated PSU:
- 8262 Dect handset PSU WW for rack charger (3BN67353AA)
- Ten Pao (Model S030ABM0500500) efficiency level VI (rating I/P: AC 100-240V, 1A; O/P: DC 5V, 5A).
- Friwo FW7540/05 (rating I/P:AC 100-240V, 600mA; O/P: DC 5V, 5A). With the 8262EX DECT Handset, use only Bluetooth devices marked with the ATEX logo, usable in an ATEX (potentially explosiveatmosphere) area. Never charge or install the battery in an ATEX (potentially explosive atmosphere) area. Regulatory Statements This equipment uses DECT frequency range that depends on country: 1880 - 1900 Mhz in Europe, 1920 - 1930 MHz in US/Canada, 1910 -1930 MHz in LATAM, 1910 - 1920 MHz in Brazil. The equivalent isotropically radiated power at the antenna is less than 110 mW or 250 mW (itdepends on the country). This equipment offers also Bluetooth Interface: frequency range 2402-2480 MHz, Radiated Power 1.72 mW. EUROPE This equipment is in compliance with the essential requirements of RED Directive 2014/53/EU (from 13 June 2017), ATEX Directive 2014/34/EU and with ROHS Directive 2011/65/UE. The Declaration of Conformity may be obtained from: ALE International 32 avenue Klber 92700 Colombes, France ebg_global_supportcenter@al-enterprise.com USA and Canada Handset: this device complies with Part 15 of the FCC Rules and with RSS of Industry Canada (FCC ID: T7HCT816X ,IC: 4979B-
CT816X). Thisdevice complies with Part 68 of the FCC Rules and with IC CS-03 Part V of Industry Canada. Chargers: this device complies with Part 15-B of the FCC Rules and with ICES-003 of Industry Canada. FCC Caution Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . This transmitter must not be co-located or opera ting in conjunction with any other antenna or transmitter. Privacy Privacy of communications may not be ensured when using the Bluetooth handset or any additionnal Bluetooth device. Exposure to Radio Frequency Signals. This device has been designed and manufactured not to exceed the SAR (Specific Absorption Rate) radio frequency power transmission limitsestablished by the different countries concerned. The SAR value measured is equal to 0.089 W/kg (the globally accepted maximum limit being1.6 W/kg). User Instructions Only use the handset in temperatures between -10C to +50C (14F to 122F). Only charge the battery at temperatures between +5 C and +45 C (41 F and 113 F). Acoustic shock protection Maximum sound pressure level for handset is compliant with European, US and Australian standards. Directive 2003/10/EC specifying the risks inherent in noise at work The ring contributes towards overall daily noise. To reduce the level, the following is recommended: reduce the setting, program a progressivering. Disposal:
The equipment must be returned to a collection point for electronic equipment waste disposal. Defective batteries must be returned to a collection point for chemical waste disposal. Related Documentation:
Other languages for these Safety and Regulatory Instructions and User Documentation are available at the following Web site:http://enterprise.alcatel-lucent.com?product=All&page=Directory. ATEX compliance information The 8262EX complies with IEC/EN60079-0 and IEC/EN60079-11 with marking I M2 Ex ib I Mb II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135C Db
-10C ~ +50C IP65 Um = 5.25VDC CE0035 Presafe 17 ATEX 9520 X IECEx PRE 17.0011X The symbol X placed after the certification number indicates that during the use of the handsets the following conditions shall be met:
1. Do not sink the device in oil or hydraulic fluid 2. Protect your device from aggressive liquids and vapors 3. In the case of suspected damage, do not use the device in hazardous zone ISEDC statement This device complies with Innovation, Science, and Economic Development Canad licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d' Innovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil nedoit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. ISEDC SAR Waring The device has been tested and compliance with SAR limits, users can obtain Canadian information on RF exposure and compliance Le prsent appareil est conforme Aprs examen de ce matriel aux conformit aux limites DAS et/ou aux limites dintensit de champ RF, les utilisateurs peuvent sur lexposition aux radiofrquences et la conformit and compliance dacqurir les informations correspondantes CS03 Warning This product meets the applicable Innovation, Science, and Economic Development Canad technical specifications. Le prsent matriel est conforme aux specifications techniques applicables d Innovation, Sciences et Dveloppement conomique Canada.
This product uses the FCC Data API but is not endorsed or certified by the FCC