all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manual | photo |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual | Users Manual | 496.52 KiB | ||||
1 |
|
External photos | External Photos | 305.64 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 |
|
Request for confidentiality | Cover Letter(s) | 109.75 KiB | ||||
1 | Test Report | |||||||
1 |
|
Test setup photos | Test Setup Photos | 1.55 MiB |
1 | User manual | Users Manual | 496.52 KiB |
FT-KL1 Installation Manual Version: 1.0 Kit(s) Contents The Key Locker controller includes all your basic components for basic install. Key Locker x 1EA CN1 Harnesses x 1EA CN2 Harnesses x 1EA Coin Dummy Battery x 1EA Accessory Parts 1. Self Drilling Screw x 6EA 2 2. Star Head Screw x 2EA 3. Rubber Cap x 2EA 4. Rubber Pad (POWER) x 1EA 5. Rubber Pad (RF) x 1EA RF Kits with remote(s), Antenna, and Antenna Cable are not included with the Key Locker controller kit. The remote(s) and antenna are modular and are not specific to the control modules. You can pair almost any Firstech remote(s) and antenna receiver to the Key Locker control module. 3 Installation Basics If you are new to installing Firstech alarm units, we recommend that you review this manual in its entirety prior to installing your first unit. Key Points to Consider Before Installation:
New Option Menus The new option menu differs completely from other Firstech systems. It is important to familiarize yourself with these as it will save time in most applications. Option Programmer (FT-OP500) Most options on this unit can be programmed with the remote(s) as well as the Option Programmer
(OP500). Please note the system must be disarmed before connecting the OP500. Otherwise, an ERROR message will show on the display of your OP500. 4 Remote Programming Routine IMPORTANT: The remotes are preprogrammed to the control module. If you need to program the remotes, follow the instructions below. Programming the Remote STEP 1: Activate Programming mode by turning the ignition key on and off (between the Acc & On positions) five times within 10 seconds. The vehicles parking lights will flash once with the successful completion of this step. STEP 2: Within a second after cycling the ignition the 5th time, tap the Lock button on the remote for a half second. The parking lights will flash once to confirm the transmitter has been coded. Programming Multiple Remotes: After the confirmation flash given in STEP 2, you can code additional remotes by tapping the Lock button on the remote(s). The parking lights will flash once confirming each additional remote. The Key Locker can store up to 4 remotes. Exiting Programming: Programming is a timed sequence. The parking lights will flash twice signaling the end of programming mode. Remote programming procedure: PTS (Push to Start Vehicles) Application STEP 1: Set the vehicle to the ignition or ON position STEP 2: Within 5 seconds push to the OFF position STEP 3: Within 5 seconds set the vehicle to the ignition or ON position (do not start) STEP 4: Step on the foot brake 3 times within 5 seconds *parking lights will flash 1 time to indicate remote programming is enabled STEP 5: Tap (a quick 0.5 second press and release) the lock button on the remote * the parking lights will flash 1 time indicating the remote code has been accepted STEP 6: After 10 seconds of no valid remote codes being transmitted the Key Locker will automatically exit programming mode Note: If no valid remotes are programmed the Key Locker will en te r valet mode. 5 Placement and Use of Components IMPORTANT: The placement and use of components are critical to the performance of this system. Antenna and Cable Firstech antennas are calibrated for horizontal installation at the top of the windshield. It does not have to be mounted in the top left corner as shown to the left. The cable that connects the antenna to the brain must be free from any pinches or kinks. Installing the antenna in areas other than the windshield may adversely affect the effective transmitting distance of the remotes. FT-TP1(Remote Paging Sensor) The FT-TP1 has multiple features including: remote paging, 4-digit pin unlock/disarm, and arm/
lock. All features are operated with a simple touch of the sensor. FT-TP1 functions do not require programming. NOTE: If you enter the wrong code more than 5 times within 30 minutes the TP1 function will be disabled for 1 HOUR. Alarm rearm and lock To rearm hold your finger on the Red Circle for 3 seconds. Alarm disarm and unlock To disarm hold your finger over the Red Circle for 3 seconds. Once the LEDs start their circular pattern, enter your 4-digit code by touching the window with the flat part of the tip of any finger over the number for each digit of your code. (Refer to Step 4 above or training video at www.firstechdata.com) Two seconds after entering the 4th digit, your system will first re-arm/lock. In two seconds, it will disarm/
unlock. 2 Way LCD remote paging To page a 2 Way LCD remote, hold your finger over the Red Circle twice. Touch Panel Sensitivity To change touch sensitivity, open the drivers door, hold the button on the back of the TP1 until the LEDs go out. Release button and tap again. The number of solid LEDs represent sensitivity of touch, 1 being the lowest, 5 the highest. Common Procedures Valet Mode When servicing or loaning your vehicle to others, your Key Locker system should be placed in Valet Mode. Valet Mode disables all alarm functions. IMPORTANT: While in Valet mode the Key Locker will still lock and unlock power lock systems. The system can be put into valet one of two ways:
1. Turn the vehicles key to the ignition on position and tap the Lock and Trunk buttons simultaneously for a half second. The parking lights will flash once to confirm the system is in Valet Mode. Repeat this process to take the system out of Valet Mode. Ignition does not have to 6 be on. Upon holding the same buttons again the parking lights will flash twice to confirm the system is out of Valet Mode. 2. You can put the system into Valet by holding the foot brake(data input only) and then turning the ignition key on and then off five times within 10 seconds. The parking lights will flash once to confirm the system is in Valet Mode. Key Locker Wiring Schematic Connector 1 (CN1), Black 12-Pin Harness Pin 1 Red - Constant 12V positive (+) power input. This wire must be connected. The proper vehicle wire will test (+) 12V at all times - while the key is in the off position, the on position and during crank. Pin 2 Black - Ground negative (-) input. This wire must be connected to the vehicles ground. Pin 3 Red/Black Constant 12 V positive (+) input and (+) charging output. Pin 4 Black - Ground negative (-) input. Pin 5 Violet/White - [POC 1] Starter Kill 250mA latched negative (-) output. Note: There are additional POC setting options for this POC. 7 Pin 6 Light Blue - [PIC 1] Door (default setting) negative (-) programmable input. There are additional options for this PIC. Please see Special Options Group 3. Pin 7 Orange/Black [POC 2] Horn 250mA negative (-) output. There are additional POC setting options for this POC. Pin 8 Light Blue/White - [PIC 2] Trunk (default setting) negative (-) programmable input. There are additional options for this PIC. Please see Special Options Group 3. Pin 9 Blue - [POC 3] Lock 250mA, 800mS (-) negative output. There are additional POC setting options for this POC. Pin 10 Violet/Black - [PIC 3] Arm (default setting) negative (-) programmable input. There are additional options for this PIC. Please see Special Options Group 3. Pin 11 Blue/Black - [POC 4] Unlock 250mA, 800mS (-) negative output. There are additional POC setting options for this POC. Pin 12 Brown/White - [PIC 4] Disarm (default setting) negative (-) programmable input. There are additional options for this PIC. Please see Special Options Group 3. Connector 2 (CN2), White 10-Pin Connectors Black 4-Pin (UART Data Port) ADS data to data only This connector is used for updating control modules via www.firstechdata.com. This port provides simple connectivity of iDatalink modules. Pin 1 Red/White - 12V positive (+) output. Pin 2 Black - Ground (-) output. Pin 3 Yellow/Black - RX Input, this wire receives data Pin 4 White/Black - TX Output, this wire transmits data Grey 4-Pin (UART Data Port) Drone data to data only Pin 1 Red/White - 12V positive (+) output. Pin 2 Black - Ground (-) output. Pin 3 Yellow/Blue - RX Input, this wire receives data. Pin 4 White/Blue - TX Output, this wire transmits data. White 4-Pin (Pre-wired FT-TP1) Pin 1 Black - Ground (-) output. Pin 2 Yellow/Red - Negative (-) paging input. Pin 3 Red/White - 12V positive (+) output. Pin 4 White/Red - 9V positive (+) L.E.D. output. BLUE 4-Pin to 4-Pin or 6-Pin (Pre-wired Antenna Cable) Connect your antenna cable to this port. You can only use 4 to 4 pins or 4 to 6 pin antenna cables. Pin 1Yellow - RX input. This wire receives the signal from remote. Pin 2 White - TX output. This wire transmits the signal to remote. Pin 3 Red/White - 12V positive (+) output. Pin 4 Black - Ground (-) output. 8 Option Programming Tables OPTION GROUP #1
#1 Feature Default(I) Optional(II) Optional(III) Optional(IV) Setting 1-2 Lock / Unlock pulse duration. 0.8 sec 2.5 sec 0.125 sec 3.5 sec 1-3 Driver's priority unlock 1-4 Double pulse unlock. Off Off On Unlock Lock Both Lock and Unlock 1-7 Unlock / Disarm With Trunk Release Unlock, Factory Disarm, Factory Disarm, and Trunk Release Trunk Release Only Trunk Release Only Passive locking w/ Passive Arming No Passive Locking w/ Passive Arming 1-8 Locking while in Passive Arming 1-10 Auto Relock (If a door is not opened within this amount of time.) 1-11 Ignition / Accessory Out Upon Unlock Off Off Off 30 sec 60 sec 5 min Ignition Pulse-same timing Acc Pulse-same timing as disarm pulse as disarm pulse Ig and Acc Pulse-same timing as disarm pulse 1-13 Double pulse disarm Standard Double Pulse 1-15 Trunk Output Timing 1sec 2 sec 1-16 Horn Mute Control on Remote Disabled Enabled 3 sec 4 sec OPTION GROUP #2
#2 2-1 2-2 Feature Setting Default(I) Optional(II) Optional(III) Optional(IV) Key Locker Type RF Shield Type Coin Battery Type Key Locker RF Shielding Time When LF detection of Vehicle 60 sec 30 sec 20 sec 10 sec 2-3 Key Locker 'Roof Lock'
Disabled Enabled OPTION GROUP #3
#3 3-2 3-3 3-4 3-5 Feature Setting Default(I) Optional(II) Optional(III) Optional(IV) Confirmation Horn Medium (30mS) Short (15mS) Normal (60mS) Dome Light Delay Off 5 sec 45 sec Starter-Kill relay. Anti-Grind + Starter Kill Anti-Grind Anti-Grind + Passive Starter Kill Anti-Jacking Starter-kill Ignition-Kill (no Anti-Grind) Auto 9 3-6 Factory Alarm Option On Off 3-7 Horn Duration (Upon Alarm Trigger) 30 sec 60 sec 120 Sec Horns for 20 seconds 3-8 Horn Output On Double Lock Only On Lock and Unlock 3-15 Soft Disarm Off On Disarm 1 Press OPTION GROUP #4
#4 4-1 4-2 4-3 4-4 Feature Aux 1 output Aux 2 output Default(I) Optional(II) Optional(III) Optional(IV) Setting 0.5sec 0.5sec Latch 0.5 sec Pulse + Program Program Latch 0.5 sec Pulse + Program Program Aux 1 output Control By Remote Aux 2 output Control By Remote Arm Arm Disarm Input Trigger Disarm Input Trigger 4-14 Low Battery Warning OFF ON (at 11.7 Volts) SPECIAL OPTION GROUP #1 S-#1 Feature Setting Value 1 2 AUX1 output time 1 ~ 99 [seconds], LA(Latch), 1~15 [minutes]
AUX2 output time 1 ~ 99 [seconds], LA(Latch), 1~15 [minutes]
SPECIAL OPTION GROUP #2 S-#2 Feature Programmable Output Connector Setting Value Optional 1 POC #1 (Default : Starter Kill) 2nd LIGHT [ 1 ]
Aux1 [ 10 ]
Deleted Starter Kill [ 29 ]
2 POC #2 (Default : Horn) Deleted Aux2 [ 11 ]
chirp-2 [ 20 ]
3 POC #3 (Default : Lock) 2nd IG1 [ 3 ]
Deleted Deleted 4 POC #4 (Default : Unlock) 2nd ACC [ 4 ]
Deleted Deleted Deleted Deleted Deleted REARM [ 6 ]
Deleted Lock [ 25 ]
DISARM [ 7 ]
Deleted Unlock [ 26 ]
HORN [ 8 ]
Deleted Priority Unlock [ 27 ]
10 DOME LIGHT [ 9 ]
GWA [ 18 ]
Trunk Release [ 28 ]
SPECIAL OPTION GROUP #3 S-#3 Feature Programmable Input Connector Setting Value Optional 1 PIC #1 (Default: (-) Door Input)
(-) E- Brake Input [1]
when Wire triggered Same
(-) Arm Input [15]
(-) Disable Arm/Disarm Time [ 8 ]
2 PIC #2 (Default: (-) Trunk Input)
(-) Trunk Input [2]
(N/C) Trunk Input [9]
(-) Disarm Input [16]
3 PIC #3 (Default: (-) Arm Input)
(-) Key Sense Input [3]
(N/C) Key Sense Input [10]
(-) IGN & Sensor Bypass Input [17]
4 PIC #4 (Default: (-) Disarm Input)
(-) Hood Input [4]
(N/C) Hood Input [11]
(-) AUX 1 trigger input [18]
(-) Door Input [5]
(N/C) Door Input [12]
(-) AUX 2 trigger input [19]
Deleted
(-) Pre-warn Input [13]
Deleted
(-) Instant Trigger Input
[14]
*Once programmed, this feature requires activation from the remote. Please refer to the remote user manual or the option description below. Option Menu Descriptions 1-02 Lock / Unlock Pulse Duration: This does not affect the behavior of the factory arm output
(orange wire) or factory alarm disarm output (orange/white wire). FO1 - 0.8 seconds: (-) Negative lock and unlock output time. FO2 - 2.5 seconds: (-) Negative lock and unlock output time. FO3 - 0.125 seconds: (-) Negative lock and unlock output time. This option may be helpful when using lock/unlock to arm/disarm vehicles that may roll windows down with factory Arm/Disarm wires when the standard output is too long. FO4- 3.5 seconds: (-) Negative lock and unlock output time. 1-03 Drivers Priority Unlock: FO1 - Off: (default) FO2 - On: This feature will allow the user to unlock the drivers door first. If the unlock button is pressed again within 4 seconds, the other doors will unlock. The drivers door unlock must be isolated from the other doors and use the blue (-) unlock. The Orange/Black (-) 2nd unlock (POC setting) is used to provide unlock output to unlock all other doors.1-04 1-04 Double Pulse Unlock: FO1 - Off: (default) FO2 - Unlock: This option will provide a double pulse output only for unlock each time the Key Locker executes the unlock command. (Length of output time will be based on feature 1-02 option settings.) 11 FO3 - Lock: This option will provide a double pulse lock output only for lock each time the Key Locker executes the lock command. (Length of output time will be based on feature 1-02 option settings.) FO4 - Lock and unlock: This option will provide a double pulse lock output for both lock and unlock each time the Key Locker executes lock or unlock commands. (Length of output time will be based on feature 1-02 option settings.) 1-07 Unlock/Disarm With Trunk Release: FO1 - Unlock, Factory Alarm Disarm (FAD) trunk release: This option will send unlock and FAD outputs prior to sending the Trunk release output. This applies to analog and data to data situations. FO2 - Factory Alarm Disarm (FAD) with trunk release: This option will send the FAD output prior to sending the trunk release output. This applies to analog and data to data situations. FO3 - Trunk release only: This option will only send the trunk release output when triggered. This applies to analog and data to data situations. 1-08 Locking While in Passive: When options 2 or 3 are selected the user has the choice to activate Passive feature using a Firstech remote or Drone (please check specific remote users manual for steps to activate passive) FO1 - Off: (default) FO2 - Passive locking with passive arming: This option, when passive is activated will send lock/arm outputs to lock/arm the Key Locker 30 seconds after the last zone is closed. The Key Locker will flash the parking lights the horn 1 time every 10 seconds 3 times total as a warning that it is going to Arm/lock itself. FO3 - No lock output with Passive arm: This option, when passive arm feature is activated, will NOT send the lock command one the Key Locker has passively armed itself. The Key Locker will flash the parking lights the horn 1 time every 10 seconds 3 times total as a warning that it is going to arm itself. 1-10 Auto Relock (If Door is not Opened Within Set Time) FO1 - Off: (default) FO2 - 30 seconds: This option allows the Key Locker to automatically relock/rearm 30 seconds after Key Locker has been disarmed/unlocked. This will only happen if no zones have not been opened. FO3 - 60 seconds: This option allows the Key Locker to automatically relock/rearm 60 seconds after Key Locker has been disarmed/unlocked. This will only happen if no zones have not been opened. FO4 - 5 minutes: This option allows the Key Locker to automatically relock/rearm 5 minutes after it has been disarmed/unlocked. This will only happen if no zones have not been opened. 1-11 Ignition + Accessory Pulse with Disarm: FO1 - Off: (default) FO2 - Ignition (+) and (-) pulse output with disarm: This option will pulse both (+) and (-) ignition wires upon unlock/disarm. Most new Ford vehicles require ignition pulsed + immobilizer with unlock to disarm the factory alarm. FO3 - Accessory (+) and (-) pulse output with disarm: This option will pulse both (+) and (-) accessory wires upon unlock/disarm. FO4 - Ignition (+) and (-) pulse and Accessory (+) and (-) pulse output with disarm: This option will pulse both (+) and (-) ignition and accessory wires upon unlock/disarm. Some new Ford vehicles require ignition and accessory pulsed + immobilizer with unlock to disarm the factory alarm. Important: Also used in cases where the vehicles radio may turn on and stay on until the door is opened when accessory is pulsed. 12 1-13 Double Pulse Disarm: This feature enables the FAD output. It will pulse 2 times with a single disarm command. FO1 - Off (default): Standard single pulse output on the FAD wire.
(orange/white by default) FO2 - On: This feature will generate a double pulse output on the FAD wire. (orange/white by default) 1-15 Trunk Output Timing: This feature determines the length of output time for the (+) or (-) analog trunk release wire. FO1 - 1 Second: (default) Will provide a 250mA (-) negative output for 1 second on any POC that is programmed for trunk release or setting 28. FO2 - 2 Seconds: Will provide a 250mA (-) negative output for 2 seconds on any POC that is programmed for trunk release or setting 28. FO3 - 3 Seconds: Will provide a 250mA (-) negative output for 3 seconds on any POC that is programmed for trunk release or setting 28. FO4 - 4 Seconds: Will provide a 250mA (-) negative output for 4 seconds on any POC that is programmed for trunk release or setting 28. 1-16 Horn mute control: this feature allows the installer to enable or disable the horn mute control. The mute feature will silence the horn during arm, disarm from the Firstech remote. FO1 - Disabled: (default) will not allow for the Firstech remote to mute the horn output. FO2 - Enabled: this feature will allow the end user to activate or deactivate the horn mute control. 2-01 Key Locker : Key Locker Type can be selected.. FO1 - RF Shield Type: (default) It operates as RF shield type. FO2 - Coin Battery Type: It operates as Coin Battery Type. In other words, RF Shield does not work.. 2-02 Key Locker RF Shielding Time : When option 2-1-1 is set, it is possible to determine the time for RF Shield to operate when LF emission of vehicle is detected. FO1 60 sec: (default) When LF transmission of vehicle is detected, RF Shield (LF Jamming) is output continuously for 60 seconds. FO2 30 sec: When LF transmission of vehicle is detected, RF Shield (LF Jamming) is output continuously for 30 seconds. FO3 20 sec: When LF transmission of vehicle is detected, RF Shield (LF Jamming) is output continuously for 20 seconds. FO4 10 sec: When LF transmission of vehicle is detected, RF Shield (LF Jamming) is output continuously for 10 seconds. 2-03 Key Locker 'Roof Lock' : You can decide whether to lock the key locker. FO1 Disable: (default) FO2 Enable 3-02 Confirmation Horns: This feature will allow the user to select a shorter horn output time to simulate a quieter arm/disarm output. FO1 - 30mS: This is a 30 milliseconds horn output with arm, disarm confirmation horns. It will produce a medium volume sound. (Softer than the standard 60mS output) FO2 - 15mS: This is a 15 milliseconds horn output with arm, disarm confirmation horns. It will produce a short or quiet volume of sound. (Significantly softer than the standard 60mS output) 13 FO3 - 60mS: This is a standard 60 milliseconds horn output with arm, disarm confirmation horns. 3-03 Dome Light Delay: This option is used when connecting the door trigger input to the vehicles dome light circuit. It delays the door trigger input to prevent the door open icon displaying on 2 Way remotes upon lock/arm. FO1- Off: (default) FO2 - 5 seconds: This option will delay the door trigger input for 5 seconds when arming the system to account for any vehicle dome light output delay. FO3 - 45 seconds: This option will delay the door trigger input for 45 seconds when arming the system to account for any vehicle dome light output delay. FO4 - Auto: This option will allow the Key Locker to wait for a change in polarity on the door input circuit, after the system has been armed, to monitor for security. 3-04 Starter-Kill: This option determines the operation of the GWA wire (Any POC on CN3) Must be programmed on Special Option Group #2. FO1 - Anti grind + Starter interrupt: this option will allow the GWA to provide a negative output when the system is armed or remote started. This will enable a starter interrupt to prevent the vehicle from being started with the key when in an armed state. FO2 - Anti Grind only: This option will allow GWA to provide a negative output when the system is armed. This will enable starter interrupt and prevent the user from grinding the starter during the takeover procedure. FO3 - Anti Grind and passive starter interrupt: This option will allow for GWA to provide a negative output when the system is remote started or the passive starter interrupt is engaged. This will prevent the user from grinding the starter during the takeover procedure and enable starter interrupt 60 seconds after the ignition has been turned off. 3-05 Anti-Jacking: this requires the starter-kill relay to be wired to the ignition vs. the starter wire This feature will allow the Key Locker to interrupt the ignition wire if panic mode is activated while the vehicle is running with the key. FO1 - Off: (default) anti-carjacking feature is not enabled and the starter interrupt will operate based on feature 3-04 option setting. FO2 - On: this option will enable the anti-carjacking feature. Make sure the starter interrupt relay is wired to interrupt the vehicles ignition wire, so the feature will operate as described. While the vehicle is running with the key and the panic mode is activated using any Firstech 4 button or 2-
way LCD remote, the key Locker will enable the ignition interrupt relay so the vehicle cannot be re-
started. Note: When using ignition-kill on manual transmission vehicles feature 3-04 must be set to option 2 will need to be utilized. this disables the anti-grind circuit while the vehicle is remote-
started; if the anti-grind circuit is active and the start-kill relay is installed in the ignition, the relay will buzz while remote-started. Security features include sensor inputs, zone inputs (unless using with manual transmission), horn output. Basic features will function normally (lock, unlock, trunk release, remote start, parking lights.) Please note the control module model when determining the correct feature option. FO1 - On: Depending on the Control Module this option will enable the security features. FO2 - Off: Depending on the Control Module this option will disable the security features. 3-06 Security Features: This feature will enable or disable the security features of the Key Locker. 3-07 Horn Duration Upon Alarm Trigger: this feature changes the duration of the horn during full alarm. FO1 - 30 seconds: this option will provide 30 seconds of output (+) on the horn during full alarm. FO2 - 60 seconds: this option will provide 60 seconds of output (+) on the horn during full alarm. FO3 - 120 seconds: this option will provide 120 seconds of output (+) on the horn during full alarm. 14 FO4 - Horns for 20 seconds: this option will provide 20 seconds of pulsed output (+) on the horn during full alarm. 3-08 Horn Output: This feature controls the horn output behavior during Arm, Disarm (POC setting #8) FO1 - On double lock only: (default) this option is designed to simulate a factory keyless entry system by providing a horn output pulse (based on the option selection of feature 3-02) each time the lock command is sent a second time within 8 seconds of the first lock command. FO2 - On lock and Unlock only: this option will provide a horn output pulse (based on the option selection of feature 3-02) with each lock or unlock confirmation. 3-15 Soft Disarm: this feature will enable Factory Alarm Arm (FAA) and Factory Alarm Disarm (FAD) outputs to trigger when silencing the horn when sounding with full alarm. FO1 - Off: (Default) this will keep the standard soft disarm operation. Soft disarm feature allows the user to silence the horn as its sounding with full alarm without fully disarming the system which may unlock the doors and leave the vehicle unsecure. FO2 - On: this option will provide a FAD output on both data and analog connections, when the user taps the unlock/disarm once to silence the system while its sounding, so it will disarm any factory alarm that may be sounding as well. In case the FAD function unlocks the doors the Key Locker will send the FAA on both data and analog connections 5 seconds later to make sure the vehicle is re-locked and secure. (This feature works well with GM, Chrysler, Dodge, Jeep, Toyota, Lexus vehicles that may have factory security.) 4-01 Aux 1 Output: This feature determines the duration of the auxiliary 1 output. (Option 4 allows the output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update only) (Specific time setting only available when using the OP500) FO1 - 500mS: This option will provide a (-) negative output for 500 milliseconds (Half second) output on any POC programmed with setting 10 (AUX 1) FO2 - Latched: This option will provide a latched (-) negative output on any POC programmed with setting 10 (AUX 1). Note: This will stay latched until AUX 1 command is sent again to shut it off. FO3 - 500mS pulse + programmable timed output: This option will provide a (-) negative output for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 10 (AUX 1). It will pause for 250 milliseconds then provide a timed output (based off of feature 4-01 option 4). Note:
in order to program the timed output the user must change feature 4-01 to option 4, then adjust AU1 (AUX programmable output time) to desired time. To complete the programming steps feature 4-01 must be changed to option 3. I.e. 0.5 second pulsepause10 second pulse, this option can be used to roll windows up or down on a vehicle that requires a similar action using the drivers door key cylinder. FO4 - Program: This option allow the AUX output time to be programmed for a duration between 1-99 seconds. Note: with an OP500 update there will be additional time duration between 1-15 minutes available. 4-02 Aux 2 Output: This feature determines the duration of the auxiliary 2 output. (Option 4 allows the output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update only) only available when using the OP500) FO1 - 500mS: This option will provide a (-) negative output for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 11 (AUX 2) 15 FO2 - Latched: This option will provide a latched (-) negative output on any POC programmed with setting 11 (AUX 2). Note: This latched output will reset when ignition is turned on. FO3 - 500mS pulse + programmable timed output: This option will provide a (-) negative output for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 11 (AUX 2). It will pause for 250 milliseconds then provide a timed output (based off of feature 4-02 option 4). Note:
in order to program the timed output the user must change feature 4-02 to option 4, then adjust AU2 (AUX programmable output time) to desired time. To complete the programming steps feature 4-01 must be changed to option 3. (i.e. half second pulsepause10 second pulse) This option can be used to roll windows up or down on a vehicle that requires a similar action using the drivers door key cylinder. FO4 - Program: This option allows the AUX output time to be programmed for a duration between 1-99 seconds. Note: The OP500 must be updated for additional time duration settings. (1-15 minutes available) 4-03 Aux 1 Output Control: This feature allows the user to configure the method of which Auxiliary 1 can be activated. FO1 - Remote: (default) This option allows AUX 1 (output time based on feature 4-01) to be triggered by any 4 button Firstech remote or drone. FO2 - With Arm: This option will trigger AUX 1 (output time based on feature 4-01) any time the Key Locker is locked/armed the first time (i.e. if you send a second lock/arm command it will not trigger again) FO3 - With Disarm: This option will trigger AUX 1 (output time based on feature 4-01) any time the Key Locker is unlocked/disarmed. Note: the system has to be in the armed state when disarming in order to trigger AUX 1. (I.e. if the vehicle is already in the unlocked/disarmed state and you send a second unlock/disarm command it will not trigger the output) FO4 - Input trigger: this option will activate the AUX 1 output (output timing based on feature 4-01) When a PIC (programmable input channel) set to AUX1 Trigger Input sees a pulsed or latched ground source. 4-04 Aux 2 Output Control: This feature allows the user to configure the method of which Auxiliary 2 can be activated. FO1 - Remote: (default) This option allows AUX 2 (output time based on feature 4-02) to be triggered by any 4 button Firstech remote or drone. FO2 - With Arm: this option will trigger AUX 2 (output time based on feature 4-02) any time the Key Locker is locked/armed the first time (I.e. if you send a second lock/arm command it will not trigger again) FO3 - With Disarm: This option will trigger AUX 2 (output time based on feature 4-02) any time the Key Locker is unlocked/disarmed. Note: the system has to be in the armed state when disarming in order to trigger AUX 1. (I.e. if the vehicle is already in the unlocked/disarmed state and you send a second unlock/disarm command it will not trigger the output) FO4 - Input trigger: this option will activate the AUX 2 output (output timing based on feature 4-02) When a PIC (programmable input channel) set to AUX2 Trigger Input sees a pulsed or latched ground source. 4-14 Low Battery: This feature offers low battery options to help alert the user of a low battery in the vehicle. FO1 - Off: (default) This option does not provide a low battery indication. 16 FO2 - On: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when the vehicles battery voltage (at the Key Locker power connector) drops to 11.7volts. Note: the Firstech 2 way LCD remote must be within range of the vehicle to receive the low battery alert and this option must be set in order to receive low battery alerts to Drone. Special Option Groups 1 and 2 IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2. Special Option Group 1 FO1 - Aux 1 Output Timing: (Option 4-01 must first be set to setting 4.) This special option allows a specific output duration for Aux 1 to be programmed 1-99 seconds. Note with OP500 update, latched output time 1-15 minutes are available for programming in addition to the standard 1-99 seconds. FO2 - Aux 2 Output Timing: (Option 4-02 must first be set to setting 4.) This special option allows a specific output duration for Aux 2 to be programmed 1-99 seconds. Note with OP500 update, latched output time 1-15 minutes are available for programming in addition to the standard 1-99 seconds. Special Option Group 2 This special option group allows you to determine the output type of the POC wire. For example, if you want to set POC #5 (default setting status out) to Aux 1, you will need change special option 5 to number 10. This must be done with the OP500. POC 1 VIOLET/WHITE (default setting) This channel will provide a 250mA (-) negative output when the Key Locker is armed (function also POC setting 29) POC 2 ORANGE/BLACK Horn: (default setting) This channel will provide a 250mA output when Horn is triggered. (function also POC setting 8) POC 3 BLUE Lock: (default setting) This channel will provide a 250mA output with the lock/arm command. (function also POC setting 25) POC 4 - BLUE/BLACK Unlock: (default setting) This channel will provide a 250mA output with the unlock/disarm command. (function also POC setting 26) POC setting value description (SV) SV 1 - Parking light: provides a 250mA (-) negative parking light output on any POC programmed with this setting. SV 3 - Ignition: provides a 250mA (-) negative ignition output on any POC programmed with this setting. SV 4 - Accessory: provides a 250mA (-) negative accessory output on any POC programmed with this setting. SV 6 - FAA (Factory Alarm Arm): provides a 250mA, 800mS (-) negative output with the arm/lock command on any POC programmed with this setting. SV 7 - FAD (Factory Alarm Disarm): provides a 250mA, 800mS (-) negative output with the disarm/unlock command on any POC programmed with this setting. SV 8 - Horn: provides a 250mA (-) negative output with output control based on feature 3-08 option setting when using any POC programmed with this setting. 17 SV 9 - Dome light supervision: provides a 250mA (-) negative output with the disarm/unlock command, on any POC programmed with this setting, for up to 45 seconds or until ignition is on. SV 10 - AUX1: provides a 250mA (-) negative output (based on feature 4-01 setting) when AUX is triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC programmed with this setting. SV 11 - AUX2: provides a 250mA (-) negative output (based on feature 4-02 setting) when AUX is triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC programmed with this setting. SV 18 - GWA (ground While Armed): provides a 250mA (-) negative output on any POC programmed with this setting, while the system is armed or locked. SV 20 - Siren 2: provides a 250mA latched (-) negative output on any POC programmed with this setting, only with the full alarm or panic modes. May be used to power any additional horn or sirens while the Key Locker is in full alarm or panic mode. SV 25 - Lock: provides a 250mA, 800mS (-) negative output on any POC programmed with this setting, with the lock/arm command. SV 26 - Unlock: provides a 250mA, 800mS (-) negative output on any POC programmed with this setting, with the unlock/disarm command. SV 27 - 2nd Unlock: provides a 250mA, 800mS (-) negative output on any POC programmed with this setting, when using the drivers door priority feature. This wire would be used to unlock the rest of the doors while unlock should be used to unlock the isolated drivers door. Note:
this output can only be activated within 5 seconds after the first unlock command is sent. SV 28 - Trunk release: provides a 250mA, 1 second (-) negative output (output timing based on feature 1-15 on any POC programmed with this setting, with the trunk release command. SV 29 Starter Kill: provides a 250mA (-) negative output on any POC programmed with this setting, while the system is armed or locked, and during remote start for Anti-Grind. Special Options Group 3 This special option group allows you to determine the input type of the PIC
(Programmable Input Channel) wire. i.e. If you want to set PIC #5 (default setting (-) hood status INPUT) to (N/C) hood pin INPUT, you will need change special option 4 from 0 to number 11 using your OP500. PIC 1 - LIGHT BLUE: (-) Door INPUT (default setting) (function also PIC setting 5) PIC 2 - LIGHT BLUE/WHITE: (-) Trunk Status INPUT (Trunk input) (default setting) (function also PIC setting 2) PIC 3 - VIOLET/BLACK: (-) Arm INPUT (default setting) (function also PIC setting 15) PIC 4 - BROWN/WHITE: (-) Disarm INPUT (default setting) (function also PIC setting 16) PIC setting value description (SV) SV 1 - (-) E-Brake INPUT: This setting allows any PIC programmed with value 1 to be used as a (-) negative parking /emergency brake INPUT. SV 2 - (-) Trunk Status INPUT: This setting allows any PIC programmed with value 2 to be used as a
(-) negative Trunk status INPUT. This can be used as a single trunk or multi rear door input for security or Manual transmission remote start. SV 3 - (-) Key-Sense INPUT: This setting allows any PIC programmed with value 3 to be used as a (-) negative Key-sense INPUT. Key sense is recommended when remote starting manual transmission vehicle. SV 4 - (-) Hood Status INPUT: This setting allows any PIC programmed with value 4 to be used as a
(-) negative Hood Status INPUT. This can be used as a single hood pin input for security or Manual transmission remote start. SV 5 - (-) Door Status INPUT: This setting allows any PIC programed with value 5 to be used as (-) negative Door Status. This can be used as a single door or multi door input for security or Manual transmission remote start. SV 8 - (-) Disable ARM/Disarm/Start INPUT: This setting allows any PIC programmed with value 8 to 18 be used as a (-) negative arm/disarm/start disable INPUT when controlling the Key Locker through analog arm/disarm/start inputs. (will disable the analog disarm input command if ground is present on both disarm input wire and disarm disable input wire simultaneously) SV 9 - (N/C) Trunk INPUT: This setting allows any PIC programmed with value 9 to be used as a Normally Closed-circuit Trunk pin INPUT. The Key Locker will consider the zone open when ground is removed or the circuit status changes from (-) ground to power. This can be used as a single trunk zone input for security or remote start SV 10 - (N/C) Key Sense INPUT: This setting allows any PIC programmed with value 10 to be used as a Normally Closed-circuit Key Sense Input. The Key Locker will consider the key to be in the key cylinder if when ground is removed or the circuit status changes from (-) ground to power. Key sense is recommended when remote starting manual transmission vehicle. SV 11 - (N/C) Hood Status: This setting allows any PIC programmed with value 11 to be used as a normally closed-circuit hood pin INPUT. The Key Locker will consider the zone open when ground is removed or the circuit status changes from (-) ground to power. This can be used as a single hood zone input for security or remote start SV 12 - (N/C) Door INPUT: This setting allows any PIC programmed with value 12 to be used as a normally closed-circuit door pin INPUT. The Key Locker will consider the zone open when ground is removed or the circuit status changes from (-) ground to power. This can be used as a SINGLE (1) door zone input for security or remote start. SV 13 - (-) Pre-Warn INPUT: This setting allows any PIC programmed with value 13 to be used as an Auxiliary sensor prewarn Input. Once Armed the Key Locker will activate the prewarn horns if this input sees ground/negative input. SV 14 - (-) Instant Trigger INPUT: This setting allows any PIC programmed with value 14 to be used as an Auxiliary Sensor Instant Trigger Input. Once Armed the Key Locker will activate the Instant trigger, sounding the alarm, if this input sees ground/negative input. SV 15 - (-) Key Locker ARM INPUT: This setting allows any PIC programmed with value 15 to be used as a Control Module ARM input which will arm the brain, activating lock/arm outputs if necessary. SV 16 - (-) Key Locker DISARM INPUT: This setting allows any PIC programmed with value 16 to be used as a Control Module DISARM input which will Disarm the brain, activating unlock/disarm outputs if necessary. Will also disarm the brain when its sounding or has been triggered. SV 17 - IGN & Sensor Bypass INPUT: This setting allows any PIC programmed with value 17 to be used to bypass the Key Locker ignition input and the alarm sensor inputs while armed if it is being used with a factory Remote Start or added to another device. This input needs to see
(-) on the input to use it properly. SV 18 - (-) AUX 1 Trigger INPUT: This setting allows any PIC programmed with value 18 to be used to activate AUX1 output (timing output based on feature 4-01) with a Pulsed or latched ground/negative source. SV 19 - (-) AUX 2 Trigger INPUT: This setting allows any PIC programmed with value 19 to be used to activate AUX2 output (timing output based on feature 4-02) with a Pulsed or latched ground/negative source.
**There are several benefits to using the PIC inputs:
Example 1: 4 N/C door inputs would be available for Manual transmission scenario without requiring a module, wire cutting, resistors, diodes, or relays Example 2: 4 individual (-) door inputs could be connected (with no diodes) eliminating the need for diodes to isolate the door pins from each other when connecting multiple door pins to 1 door input on the Key Locker Example 3: Allow for a N/C hood pin or Trunk pin input that doesnt require a module, wire cutting, diodes, resistors, or relays Example 4: will make the Key Locker an install more efficient by allowing for unused inputs to be reprogrammed for other functional inputs 19 Option Programming How to Program Options There are two ways to set options on the Key Locker control modules. You can use the FT-OP500 or most Firstech remotes. The remotes include 4 or 5 button 1 and 2 Way remotes. Option Programming Using the FT-OP500 The OP500 can be used to change anything in the Option Tables. It is required to change settings in the Special Option Group. STEP 1: Make sure system is unlocked/disarmed. Connect the antenna cable to the 4 or 6 pin port on the top of the OP500. Once connected, the OP500 will power up as long as CN1 on the control module is connected properly. STEP 2: Use the left or right arrow keys on the OP500 to select option. Use the up or down arrow buttons to select the option setting. 1 is the default setting, 2, 3, and 4 are the optional settings. Special Option Group 1: Change the timed output of Auxiliary 1 and 2. STEP 3: Hold the W (Write) button for 3 seconds. This finalize option changes to the control module. Wait until OP500 displays Success before disconnecting. To reset the options, hold the R (Reset) button and W (Write) buttons for 3 seconds. Then hold the W button for 3 seconds. Option Programming Using Compatible Remotes Using a remote is a timed process so review this section before beginning. Options cannot be programmed with 1 button remotes. IMPORTANT: Special Option Groups cannot be programmed with remotes OP500 must be used. STEP 1: Select the option you wish to program. Use the correct remote table below:
How to Program Options With 2 Way Remotes with Separate Lock and Unlock Buttons n r o h r o f t i a W h c a e n e e w t e b p a t h g u o r h T l l o r c S r o f t i a W
(
u n e M n e e w t e b h s a l f
) p a t h c a e i g n d n o p s e r r o c Option Menu 1 Lock + Unlock for 3 seconds then Lock +
Unlock for 3 seconds Tap Key Button r o f t i a W
/
r o d n a h s a l f t h g i l i g n k r a p g n i t c e e s l e r o f e b n r o h n o i t p o 20 1 n o i t p O t c e 2 n o i t p O t c e 3 n o i t p O t c e 4 n o i t p O t c e l e S l e S Tap Lock Button Tap Unlock Button l e S Hold Trunk Button for l e S Tap Start Button Option Menu 2 Lock + Unlock for 3 seconds then Lock +
Key for 3 seconds Tap Key Button Option Menu 3 Lock + Key for 3 seconds then Lock +
Unlock for 3 seconds Tap Key Button Tap Lock Button Tap Lock Button Tap Unlock Button Tap Unlock Button 3 seconds Hold Trunk Button for 3 seconds Hold Trunk Button for 3 seconds Tap Start Button Tap Start Button n r o h r o f t i a W h c a e n e e w t e b p a t Option Menu 1 Lock + Unlock for 3 seconds then Lock +
Unlock for 3 seconds Option Menu 2 Lock + Unlock for 3 seconds then Lock +
Key for 3 seconds Option Menu 3 Lock + Key for 3 seconds then Lock +
Unlock for 3 seconds How to Program Options With 1 Way 4 Button Remotes h g u o r h T l l o r c S r o f t i a W
(
u n e M n e e w t e b h s a l f
) p a t h c a e Hold Trunk +
Key for 3 seconds Hold Trunk +
Key for 3 seconds Hold Trunk +
Key for 3 seconds
/
r o d n a h s a l f t h g i l i i g n k r a p g n d n o p s e r r o c r o f t i a W n o i t p o g n i t c e e s l e r o f e b n r o h 1 n o i t p O t c e 2 n o i t p O t c e 3 n o i t p O t c e 4 n o i t p O t c e l e S l e S l e S l e S Tap Lock Button Tap Lock Button Tap Lock Button Tap Unlock Button Tap Unlock Button Tap Unlock Button Tap Key Button Tap Key Button Tap Key Button Hold Trunk and Start for 3 seconds Hold Trunk and Start for 3 seconds Hold Trunk and Start for 3 seconds STEP 2: Scroll through menu waiting for 1 parking light flash and/or horn per line. STEP 3: Once finished scrolling through menu, wait for the parking lights and/or horn to confirm the option number. i.e. option 2-04 will flash and/or horn 4 times. Select your option using the Lock, Unlock, Trunk, or Start buttons. Resetting to Factory Defaults: To reset the options in a particular menu, enter the menu using your remote. To reset options with a 2 Way remote tap the Trunk button 3 three times. To reset options with a 1 Way remote tap the Start button 3 times. Wait for parking lights to flash and/or horn between each tap. After the third tap, the menu will reset back to default. This must be done for each option menu that must be reset. 21 Regulatory warning statement 1 USA - FCC FCC ID: VA5MCI500-LF125 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WARNING: Changes or modifications not expressly approved by the manufacturer (or party responsible) for compliance could void the users authority to operate the equipment. 2 CANADA IC IC: 7087A-MCI500LF125 This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1)this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Cet quipement doit tre install et utilis avec un minimum de 20 cm entre le radiateur et votre corps. 22
1 | Request for confidentiality | Cover Letter(s) | 109.75 KiB |
CONFIDENTIALITY REQUEST Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 2019.07.11 TO WHOM IT MAY CONCERN Pursuant to Paragraphs 0.457 and 0.459 of the Commissions Rules (47 C.F.R.) and Section 552(b)(4) of the Freedom of Information Act, SEGI LIMITED requests confidentiality for the following products:
FCC ID Number Product Title/Model VA5MCI500-LF125 Key Locker / FT-KL1 The following exhibits contain trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our product. This material is not customarily available to the general public and we request that it be withheld from public inspection. We request that the following information submitted be held permanent confidential treatment. Permanent Confidential Request
Schematics
- Block diagram
- Part List
- Operational description
- Part Location We request that the following information submitted be held short-term confidential treatment for 180 days. Short- term Confidential Request Internal photo
If you have any questions, please feel free to contact me at the address shown below. Best regards, Name: Young il Chang Title: President Company name: SEGI LIMITED Unit J2, 4/F, Block 1, Kinho Industrial Building, 14-24 Au Pui Wan Street, Shatin, New Territories HONGKONG, China E-MAIL : Segihk@gmail.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-07-16 | 0.125 ~ 0.125 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-07-16
|
||||
1 | Applicant's complete, legal business name |
SEGI LIMITED
|
||||
1 | FCC Registration Number (FRN) |
0007994122
|
||||
1 | Physical Address |
Unit J2, 4/F, Block 1, Kinho Industrial Building
|
||||
1 |
HONGKONG, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
L******@ul.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
VA5
|
||||
1 | Equipment Product Code |
MCI500-LF125
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
Y****** C****
|
||||
1 | Telephone Number |
(852)********
|
||||
1 | Fax Number |
(852)********
|
||||
1 |
s******@gmail.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 01/12/2020 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | FT-KEY LOCKER FOR CAR | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
UL Korea, Ltd.
|
||||
1 | Name |
c****** k********
|
||||
1 | Telephone Number |
82313********
|
||||
1 | Fax Number |
+82-3********
|
||||
1 |
k******@ul.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC