Stratosfy Beacon-I Stratosfy Beacon-I FCC ID : 2A3CA-STSFYBTI01 | IC : 27758-STSFYBTI01 User Manual 2500 Solandt Road, Suite 210, Ottawa, ON K2K 3G5 For more information, contact hello@stratosfy.io Website : www.stratosfy.io Version 1.0.0 Stratosfy Beacon-I User Manual Stratosfy Beacon-I is a wireless communication device that transmits Bluetooth identity messages, Summary The role of Stratosfy Beacon-I, as part of Stratosfy Workforce Management solutions, is to guarantee activities are carried out at precise locations by either registering workforce presence or unlocking location-based task lists when workers are within the device's communication range. Technology Highlights Proprietary technology Bluetooth 5 ready multi-protocol radio-based device Location precision down to 6 ft (2 m) Supports iBeacon and Stratosfy Telemetry (proprietary) packets concurrently Fully manageable devices via Stratosfys Mobile Applications Applications Stratosfy Beacon-I devices are typically meant to be installed at different interior areas of a location, such as lobbies, elevators, washrooms, meeting rooms, maintenance rooms. Stratosfy Beacon-I devices are not waterproof devices and are not meant to be installed in outdoor or exterior areas of a building/location. If your application needs outdoor service tracking please consider using Stratosfy Beacon-IO devices. Clock In Task started Task finished Clock Out How it works Stratosfy Beacon-I devices the Stratosfys mobile application used by the workforce to certify they are in precise predefined locations within a property while performing their duties. interface with The Stratosfys mobile app can detect Stratosfy Beacon-I devices when within the communications range. The app then reports the presence of the service professional and the service activities performed by the service professional to Stratosfy's cloud, along with precise and reliable location data and the timestamps automated collected during the interaction between the Stratosfy Beacon-I device and the smartphone. 2500 Solandt Road, Suite 210, Ottawa, ON K2K 3G5 For more information, contact hello@stratosfy.io Website : www.stratosfy.io Technical Specifications Model Number : STSFY-BT-I01 Number of Channels 3 Primary, 37 Secondary 0dBm (default power upon shipping), Programmable -40dBm to +8dBm RF Specifications Standard Protocol Frequency band Output power Modulation Antenna / Gain Mode of Operation Data Rates Features Memory Physical Mounting Method Housing Material Color Weight Battery Type Bluetooth 5 2.4GHz GFSK Chip antenna, 1.1 dBi half-duplex 1 Mbit/s 1 MB Flash ABS Plastic White 38 grams BLE Application Supported iBeacon, Stratosfy Telemetry Processor Type 32-bit ARM Cortex-M4F @ 64MHz Dimensions in mm (Length x Width x Height) 76 x 76 x 24 Wall Mounted with 3M Double-Sided Adhesive (included) 3V / 950mAh CR2477 Lifetime (depending on utilization) 18-24 months expected, dependent upon environmental operating conditions, device configuration, communication frequency Chemical and Mechanical Resistance Water Not Waterproof, IP61 Rating Withstands Exposure To UV Resistant, Impact Resistant Thermal Storage Operating Temperature 32F to 140F (0C to 60C) 32F to 86F (0C to +30C) 2500 Solandt Road, Suite 210, Ottawa, ON K2K 3G5 For more information, contact hello@stratosfy.io Website : www.stratosfy.io Other Standards Box Size Warranty Accessories FCC ID: 2A3CA-STSFYBTI01 IC: 27758-STSFYBTI01 10 pcs. 1 year Replacement CR2477 batteries - 3V / 950mAh Velcro tape/3M tape - 3M Velcro hook and loop capacity coin cell CR2477 batteries dual lock tape 1 inch squares 2500 Solandt Road, Suite 210, Ottawa, ON K2K 3G5 For more information, contact hello@stratosfy.io Website : www.stratosfy.io This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FCC statements IC Statements This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interfrences et (2) cet appareil doit accepter toute interfrence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. Health Canada RF Exposure Warning Statement This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Information can be obtained at http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-eng.php French version Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme d installation de cet appareil doit s assurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Les informations peuvent tre obtenues:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-eng.php Designed in Canada 2500 Solandt Road, Suite 210, Ottawa, ON K2K 3G5 For more information, contact hello@stratosfy.io Website : www.stratosfy.io