all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 1.04 MiB | February 21 2023 | |||
1 |
|
Internal Photos | Internal Photos | 762.50 KiB | February 21 2023 | |||
1 |
|
External Photos | External Photos | 341.21 KiB | February 21 2023 | |||
1 |
|
ID Label/Location Info | ID Label/Location Info | 191.25 KiB | February 21 2023 | |||
1 |
|
Agent Letter A for Service of Process FCC Attestation Statements Kiwa signed | Attestation Statements | 967.96 KiB | February 21 2023 | |||
1 |
|
AgentLetter A forServiceofProcess FCC AttestationStatements filled in | Attestation Statements | 985.17 KiB | February 21 2023 | |||
1 | Block Diagram | Block Diagram | February 21 2023 | confidential | ||||
1 |
|
Covered List Attestation FCC ApplicationLetter | Attestation Statements | 906.25 KiB | February 21 2023 | |||
1 | Operational Description | Operational Description | February 21 2023 | confidential | ||||
1 |
|
P000207337 001 v2.00 | Test Report | 1.13 MiB | February 21 2023 | |||
1 |
|
P000207337 002 v2.00 | Test Report | 625.56 KiB | February 21 2023 | |||
1 |
|
P000207337 003 v2.00 | RF Exposure Info | 389.37 KiB | February 21 2023 | |||
1 | Schematics | Schematics | February 21 2023 | confidential | ||||
1 |
|
Test Setup Photos | Test Setup Photos | 1.47 MiB | February 21 2023 | |||
1 |
|
confidentiality | Cover Letter(s) | 939.76 KiB | February 21 2023 |
1 | Users Manual | Users Manual | 1.04 MiB | February 21 2023 |
USER MANUAL REF 92-1300-0201-EN-7-0 REV 7 Last update: 2023-01-31 USER MANUAL APEX TABLE OF CONTENTS 1 SERVICE AND SUPPORT About this manual Contact information TMSi Warranty information Additional accessories Abbreviations 2 SAFETY INFORMATION Explanation of markings Limitations of use Safety measures and warnings Precautionary measures Disclosure of residual risk Information for lays 3 PRODUCT OVERVIEW Product Intended use Product views User interface Connections Triggering Device labels 4 INSTRUCTIONS FOR USE Power Apex Connect accessories Data connections Software Wearability APEX in an ME system PERFORM A MEASUREMENT Perform Stationary Measurement Perform Portable Measurement using Bluetooth Perform Card recordings Impedance Measurement Status Events OPERATIONAL PRINCIPLES APEX Unipolar input channels Tips for obtaining optimal quality data 5 6 7 MAINTENANCE Servicing and Updates Cleaning instructions Disposal instructions 8 9 ELECTROMAGNETIC GUIDANCE Degradation of performance Electromagnetic emission Electromagnetic immunity TECHNICAL SPECIFICATIONS 3 3 3 3 4 4 5 5 6 6 7 8 8 9 9 9 11 13 15 17 17 18 18 18 19 19 20 21 22 22 22 23 24 24 26 26 26 27 28 28 28 28 29 29 29 30 34 Page 2 of 38 USER MANUAL APEX 1 SERVICE AND SUPPORT About this manual This manual is intended for the user of the APEX (electro-)physiological amplifier which is also referred to as APEX, product or APEX product throughout this manual. It contains general operating instructions, precautionary measures, maintenance instructions and information for use of the product. Read this manual carefully and familiarise yourself with the various controls and accessories before starting to use the product. Contact information TMSi TMSi Support can be reached via email (support@tmsi.com) or via the website:
www.tmsi.com/support. Please provide as much information as possible, including serial numbers of the used products. This will help to support you in the best way possible. TMSi Support can be contacted in one of the following languages: Dutch or English. Manufacturer Contact Information Zutphenstraat 57 7575 EJ Oldenzaal The Netherlands Warranty information Twente Medical Systems International B.V. support@tmsi.com www.tmsi.com The product is warranted against failure of materials and workmanship for a period of one year from the date of delivery. Repairs can only be performed by the manufacturer or by TMSi authorised personnel. Warranty will terminate automatically by removal or alteration of identification labels on the product or its parts. In case seals on the enclosure are broken or removed, warranty is voided and TMSi can no longer guarantee continued safety or correct operation of the product. The warranty does not cover the following:
Failure resulting from misuse, accident, modification, unsuitable physical or operating environment, or improper maintenance. Wear and tear caused by regular and normal usage and ageing of rechargeable batteries. Failure caused by a product for which TMSi is not responsible. Damage resulting from use of non-approved accessories. Interrupted or erroneous operation of wired or wireless data transmission. Any technical or other support provided for a product under warranty, such as assistance with how-to questions and those regarding device set-up and installation, is provided without warranty. Page 3 of 38 USER MANUAL APEX Additional accessories In case you want to order additional accessories such as cables or sensors, please contact sales@tmsi.com for consultation and a detailed quotation. The product is intended to be used with approved headcaps only; the latest version of compatible accessories can be found on the TMSi website www.tmsi.com. Abbreviations Abbreviation AC BF BT CE DC Alternating Current Body Floating Bluetooth Conformit Europenne Direct Current EEG Electro-encephalography (Brain activity) EM, EMC Electro-magnetic, Electro-Magnetic Compatibility EMG EOG EU IT ME PC REF RF SN SAR TMSi UNI USB Electromyography (Muscle activity) Electro-oculography (Standing potential of the eye between front and back) European Union Information Technology Medical Equipment Personal Computer Reference Radio Frequency Serial Number Specific Absorption Rate Twente Medical Systems International B.V. Unipolar Universal Serial Bus Page 4 of 38 USER MANUAL APEX 2 SAFETY INFORMATION This section contains general warnings, explanation of markings, limitations of use, safety measures and precautionary measures important for safe use of the product. Explanation of markings This section explains the various markings and symbols used with the product. Warning: read important safety information Caution Consult instructions for use Refer to instructions for use (for USB-C connector function, chapter 4.6) Type BF applied part CE-certified, see declaration of conformity Identification of the manufacturer Date of manufacture (YYYY or YYYY-MM-DD) Ingress protection rating (where N1 and N2 are one digit each) TMSi reference number TMSi serial number Contains transmitter module Contains radio module for which the Technical Regulations Conformity Certification has been granted Special EU instructions for disposal are applicable to a product on which this symbol is placed. The Maintenance section of this manual contains information on how to dispose of this product, see chapter 7.3 Wireless sensors status indicator; see chapter 3.4 Cap connection status indicator; see chapter 3.4 PC connection status indicator; see chapter 3.4 Recording status indicator; see chapter 3.4 Power status indicator; see chapter 3.4 Power button icon; see chapter 3.4 Marker button icon; see chapter 3.4 Page 5 of 38 USER MANUAL APEX Recording button icon; see chapter 3.4 Limitations of use There are no known contra-indications to the use of the APEX product. For further information refer to chapters 2.3, 2.4 and 3.2. The design of this product did explicitly not account for potential applications, uses or environments as listed below and therefore these aspects were excluded from full risk assessment. In order to prevent any associated risks, the following limitations apply to the product:
Direct diagnosis. This product is not intended for a medical purpose. This includes, but is not limited to, the following:
- Monitoring of vital physiologic processes.
Critical applications. Life-supporting applications. Determination of electro-cerebral inactivity or silence. This product is not defibrillator-proof. This product is not intended for use in oxygen rich environments. This product is not intended for use in environments with flammable mixtures of anesthetics or agents and air, oxygen or nitrous oxide. This product is not intended for use in environments with strong magnetic fields. This product is not intended for use in environments with ionizing radiation. This product is not compatible with HF surgical equipment. This product is not intended for use on altitudes higher than 3 000 m above sea level, unless it is used in an environment where the air pressure is maintained within the range
(700 to 1 060) hPa. This product is not to be used in the presence of Magnetic Resonance Imaging (MRI) devices. NOTE While the product can be used to measure encephalic (brain) signals, it is NOT intended to be used, alone or in combination with other devices or software, for diagnostic purposes as an electroencephalograph (to produce an electroencephalogram). Safety measures and warnings Some risks associated with the intended use of the product cannot be eliminated in the product design. To avoid consequential residual risks, the following measures and warnings must be followed up for safe usage of the product. Only use accessories explicitly approved by TMSi to avoid the risk of electric shock. APEX is intended to receive its power from other electrical equipment in an ME System if not powered from the internal battery. The electrical safety is dependent on this other equipment. Refer to chapter 4.6 for further details. To avoid the risk of electric shock do not connect APEX to equipment that is not compliant with either IEC 60601, IEC 60950 or IEC 62368. Do not touch pins of disengaged connector plugs or sockets to avoid the risk of electric shock. Page 6 of 38 USER MANUAL APEX Do not use APEX together with cautery or electro-coagulation equipment on the same subject to avoid damage to the product. To avoid damage to the product do not use or store it near sources with particle radiation or elevated levels of electrical, magnetic or electro-magnetic fields. To avoid damage and reciprocal interference, only connect TMSi approved accessories and equipment to APEX. Do not use APEX together with magnetic resonance imaging equipment on the same subject to avoid reciprocal interference. Do not tamper with any part of APEX. To maintain safety, no modifications are allowed. Use of APEX adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, APEX and the other equipment should be observed to verify that they are operating normally. Use of accessories, transducers and cables other than those specified or provided by the manufacturer of APEX could result in increased electromagnetic emissions or decreased electromagnetic immunity of APEX and result in improper operation. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the APEX including its cables. Otherwise, APEX performance degradation could result. Conductive parts of electrodes and associated connectors should not contact other conductive parts, including earth. APEX is intended to be operated close to the human body and must comply with the Specific Absorption Rate (SAR) for body worn equipment to ensure compliance with RF exposure requirements set for the USA and Canada. When using APEX while wearing it on the body, maintain a distance of 10mm between APEX and the body. This can for instance be accomplished by using the APEX cradle with a 10 mm thick adhesive foam pad, which must be free of metallic components, mounted to the backside of the cradle. For use in the EU, there is no such requirement. To further comply with FCC and Industry Canada RF radiation exposure limits for general population, no transmitter or transmitter antenna must be co-located within 20 cm from the APEX. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Precautionary measures Taking the measures listed below should ensure proper operation and result in minimal undesired consequences and optimum benefit of using the product. Make sure batteries are sufficiently charged before wireless use of APEX. If necessary, connect an external power bank for charging. To prolong battery life, store APEX with preferably 40 % charged batteries and at a temperature in the range (-20 to 20) C. To avoid signal disturbance, keep APEX away from sources of strong electric, magnetic and electromagnetic radiation. To avoid loss of data, use USB communication for data transport and control. Page 7 of 38 USER MANUAL APEX Route cables for a comfortable wear and freedom of movement for the subject;
properly secure any excess cable, for example with some tape or Velcro. Prevent prolonged physical contact with metal connector parts as they may contain nickel. If necessary, tape them off using for example a bandage. If any part of APEX appears obviously malfunctioning or damaged, refrain from further using it and contact the manufacturer for repair and check of the device. When using APEX in combination with a laptop that is connected to external equipment
(monitor, ethernet, etc), please ensure that the laptop is grounded in order to avoid possible signal interference. When using APEX in combination with a laptop/PC or charger, make sure that the product is not positioned in such a way that it is difficult to operate the disconnection device. Disclosure of residual risk The intended and foreseeable use of the APEX product bears an acceptable risk. Residual risks are disclosed in chapter 2.3. Information for lays In case of subject use, the user of the product should instruct the subject on the following topics:
There are no contra-indications on the use. Dos and donts regarding use and usage environments. Specifically:
a. Keep the product clean and dry. b. Do not enter areas and environments where access is restricted. c. Keep distance from professional and amateur transmission antennas. d. When interacting with children or pets, be careful about pulling at cables. Which indicators, if any, must be monitored, how often, and how to react on specific status indications. When to press the Event marker button. How batteries have to be recharged, if their running out is expected. Contact the researcher when an unexpected situation or problem occurs. Page 8 of 38 USER MANUAL APEX 3 PRODUCT OVERVIEW Product The APEX product consists of the following components:
APEX Recorder: Electro-physiological amplifier. Accompanying documentation: Quick start guide, User Manual and certificates. TMSi APEX Device Driver. TMSi BT Dongle. The product is delivered with the following items to increase the ease of use: a suitcase, USB-C to USB-A cable, the APEX Cradle, some subject cabling and the TMSi Python Interface including a compiled application that provides a Graphical User Interface. The product is intended to be used with approved headcaps; the latest version of compatible accessories can be found on the TMSi website www.tmsi.com. Please refer to the instructions for use of those accessories, if applicable. Intended use Intended use The product is intended for acquisition of human electroencephalographic (EEG) in chapter 9 signals within Furthermore, the product is designed to log external trigger events. limitations as specified the products technical The product is not intended for a medical purpose (diagnostic, monitoring or treatment). Subject population The product is intended to be used by research professionals in a laboratory environment. APEX is also intended to be used for out-of-lab measurements. For this use case, the research professional configures the product, after which it can be handed to the subject. Data can be retrieved afterwards from the onboard memory. There are no restrictions on the subject population for which the product can be used. The product can be used on subjects regardless of age, gender or other criteria. Subject interface and operating principle The product can be worn on the body during wireless measurement setups in which case its enclosure outside is an accessible part. Contact between the subject and products subject input(s) is made by using accessories such as headcaps, in combination with gel or saline water. The product amplifies and stores signal data picked up via electrode leads or sensors that are connected to a single subject; no data interpretation is performed. Page 9 of 38 USER MANUAL APEX Applied part The product has a single Type BF applied part. It consists of the front-side sockets
(pins and shield) on the product enclosure that are marked with an applied part symbol, because these parts of the device connect galvanically to the EEG accessories. User population The product is intended to be used by, or under supervision of, a physician or research professional. The user/supervisor must have knowledge of current good practice in physiological measurement applications. User interface The different user interfaces of the product are:
The user interface of the APEX. The API offers a method to interact with the device from a PC. The application softwares user interface provides the various functionalities. The user interface of the APEX consists of an Event marker button, a Recording button, a Power button and status indicators. All status indicators are explained in chapter 3.4. The product can be controlled via the user interface of the application software running on a computer. The application software on the PC is used for storage and visualization of the acquired signal data. Use environment and conditions of use The product is intended for use on humans in a professional research laboratory environment, within environmental limits as specified in chapter 9. The product can be used as both a stationary device, as well as a portable device. Usage in environments with restricted access due to ionizing radiation and/or strong magnetic fields is excluded, as well as usage in situations referred to in chapter 2.2. The product is not intended for use in a life supporting system. The product is designed for continuous operation and is reusable without requiring any level of sterility or reprocessing. No special handling or pre-treatment is required other than connecting subject accessories between subject and APEX. APEX is also suitable for out-of-lab usage. Setting up card recordings is explained in chapter 5.3. After being instructed how to deal with the device, the subject can be sent out for a while and during that time the APEX autonomously carries out the measurement as configured. Refer to chapter 2.6 for the instructions for lays. Only use the product with the supplied parts and accessories. In case other parts or accessories are required, contact TMSi Support (support@tmsi.com) for information. Expected service life The expected service life of the device is 5 years. If the product is intended to be used after its expected service life, contact TMSi to have the product inspected before continued use. Page 10 of 38 USER MANUAL APEX The product requires no regular servicing or maintenance and no modification by users is allowed, but it may be cleaned as described in chapter 7. Repairs and modifications can only be performed by the manufacturer. The expected charging cycle life of the internal batteries for 70% remaining capacity, is 500 cycles. Batteries can only be replaced by the manufacturer. Please contact TMSi Support
(support@tmsi.com) if the batteries need to be replaced. Essential performance Under normal conditions the product ensures:
All data of a measurement session becomes available. This means that the product makes all data acquired through the product promptly available as digital data, either via streaming or through retrieval of card recording(s). However, disturbances such as mains power glitches and interference in wireless transmission may cause transient loss of streamed signal data. Input dynamic range and differential offset voltage. Input noise. Accuracy of amplitude range and sample rate. Frequency response. Common mode rejection. For information regarding performance under abnormal conditions refer to chapter 8. Refer to chapter 9 for the corresponding signal characteristics described above. Product views Top View
1. Description Physical user interface. See chapter 3.4 for more information on the LED indicators and the button markings. Page 11 of 38 USER MANUAL APEX Front and Side View Description USB-C connector. Used for charging and communication with the PC. Trigger connector.
1. 2. Bottom View
1. Description Device label. Contains SN of device. Page 12 of 38 USER MANUAL APEX Back and side view
1. 2. Description PGND connector. CAP connector. User interface Connections Type Function USB connector Gives the possibility to connect a power supply to the product or configure data transmission to be active over USB. Trigger connector Enables the user to connect an external device that generates digital trigger events. The connector supports 4 bits. Subject connections Type Function Patient Ground (PGND) lead Lead that can be connected to the subject in combination with a wristband or electrode. EEG cap (CAP) Accessory to interface the product with the subject. Typically, a headcap with either 24 or 32 channels. Page 13 of 38 USER MANUAL APEX Buttons Type Power Event marker Recording Status Indicators Function Switches the device on or off if the device is not sampling. Holding this button for 8 seconds triggers a device reset. Can be pressed by the subject or operator to log an event. Also, serves as a user confirm button to allow the pairing between APEX and the BT Dongle. Starts and stops recording on internal memory if the configuration allows a manual start/stop of the card recording. Can only be used when product is not opened in application software. Indicator Function and states Wireless Bluetooth
(BT) Sensors Reserved for future use OFF: No information available on the connection quality of the headcap. GREEN (solid): All headcap channels are within acceptable quality criteria. Headcap ORANGE (solid): Reference channel(s) that cross(es) a user-
configured warning threshold. ORANGE (blinking @ 2 Hz): All channels are disconnected, only overflow values are measured. OFF: No active connection to the PC. GREEN (solid): Active connection to the PC over USB interface available. BLUE (blinking @ 1 Hz): Waiting for pairing confirm to Dongle (that can be given by pressing the marker button). BLUE (solid): Active connection to the PC over BT interface available. ORANGE (blinking @ 2 Hz): Lost connection to the PC over BT interface. PC Connection Page 14 of 38 USER MANUAL APEX Indicator Function and states Recording OFF: There is no ongoing recording. BLUE (solid): Impedance mode is active. GREEN (solid): Sampling mode is active. GREEN (blinking @ 4 Hz): Recording button press, to stop sampling mode, is registered (as long as the button is pressed). ORANGE (solid): Card is almost full. In current configuration, less than 120 minutes of data can be stored. Or, more than 80% of the available number of recordings is stored on the device. In sampling mode, the display of this state is alternated every 4 seconds. ORANGE (blinking @ 2 Hz): Card is full. OFF: Device is in Off state. GREEN (solid): Device is in On state. When connected to external power supply, battery is full. GREEN (blinking @ 0.5 Hz): Battery is charging. Power GREEN (blinking @ 4 Hz): Power button press, to power down device, is registered (as long as the button is pressed). ORANGE (solid): Battery low (< 20% charge left). ORANGE (blinking @ 2 Hz): Battery very low (< 10% charge left). The various ORANGE LED states indicate possible warnings and error messages. Please take care when encountering one of these messages and act accordingly to troubleshoot:
"Headcap warning state: Review signal quality and assess whether this is acceptable. If not, pay attention to preparation of the measurement setup. PC connection warning state: Ensure device is not positioned too far away from PC with BT Dongle. Recording warning state: Download data from card and remove files afterwards. Power warning state: Charge the device. When APEX (User Interface) seems unresponsive to user actions, please perform a device reset such as indicated in the Power button description. Connections PGND input The Patient Ground must be connected to keep the amplifier in range. The Patient Ground connection can be made using a separate lead connected to the PGND input. For various accessories, the Patient Ground connection is also available in the CAP multi-connector. Consult the instructions for use of your accessories to check the presence of the PGND lead in the multi-connector. Page 15 of 38 USER MANUAL APEX CAP inputs The CAP multi-connector includes 24 or 32 unipolar channels to connect an EEG accessory. Wireless sensors (future use) In the future, wireless BT sensors can be integrated in the APEX measurement setup. Page 16 of 38 USER MANUAL APEX Triggering The trigger interface is accessible via the Trigger connector on the top-left side of APEX. It allows to acquire up to 4 digital input signals on the TRIGGER channel of APEX. Aside from logging events in the data stream, it is also possible to receive synchronisation events from external hardware. The trigger input is low-voltage TTL compatible and electrically isolated from the subject. Refer to chapter 9 for detailed information regarding input signals. The trigger channel employs negative logic for digital inputs, meaning that a high-voltage trigger input signal is registered as a low trigger value. Passive button presses are registered on the data stream as a high trigger value. Hence, when using a digital trigger generated, it is recommended to use a high-voltage TTL pulse as base condition, whilst using a low-voltage TTL pulse as trigger event condition. Contact support@tmsi.com for details concerning the Trigger connector. Device labels Recorder and device The device label can be found on the It contains general bottom of APEX. product information, in light text on black background specific information, black text on light background, such as Serial Number (next to SN), Reference number (next to REF) and device model. Please note that the depicted device specific information is an impression of the actual information that is found on the label. The device label also contains general product information. Please refer to chapter 2.1 for information about the meaning of all mentioned symbols. BT Dongle The BT Dongles device label consists of two parts. A black part that is imprinted on the containing housing, product general information, and a grey part that contains the device specific information, such as Serial Number (SN), Reference Number (REF) and Device Model. Page 17 of 38 USER MANUAL APEX 4 INSTRUCTIONS FOR USE Power Apex APEX can be powered by holding the Power button for a short time (1 s) or by connecting APEX via USB to a PC. APEX contains rechargeable batteries that cannot be removed from the device. When the product has been idle for more than ten minutes, it will automatically power off. The user also has the possibility to power off the product manually, by holding the power button for 1.5 s. Both conditions are only applicable when APEX is not connected via USB. Battery low indication When the battery charge is lower than a certain level (20% charge left), the Power indicator in the status indicator window becomes orange. When the battery charge is below 10%, the status indicator blinks orange to indicate that it is time to charge the product. The batteries of APEX are charged via the USB-C port. During data acquisition, APEX is not to be charged by using a charger connected to a mains power outlet. If you do wish to charge APEX during data acquisition, please use a portable power supply, such as a commercially available, certified power bank. Battery life A fully charged APEX has a battery life of approximately 2 hours. Connect accessories There are three connectors for accessories: the PGND connector, the CAP connector and the Trigger connector. The CAP multi-connector uses a Push-Pull mechanism to prevent it from getting detached inadvertently. To make a connection, observe the alignment symbols (red dot) and gently push the plug into the socket of the APEX device. To disconnect, take hold of the plug at its moving sleeve, the part closest to the socket, and gently pull the plug out. Do NOT pull at the accessory wire or at the wire end of the plug. The trigger connector fits only in one orientation, which can be seen by checking both connectors. Page 18 of 38 USER MANUAL APEX Data connections Refer to chapter 9 for used protocols, requirements and settings as applicable.
1. 2. 3. 4. Description APEX Data acquisition PC Wired interface (USB) to send commands and receive data. Wireless interface (BT) to send commands and receive data using the BT Dongle. The APEX product (1) can be connected to a PC (2) via a USB cable (3) and via a wireless BT interface, together with a Dongle (4). Both connections are used for control of the device and transfer of data to the PC where it can be stored for further processing. It is also used for sending commands from application software to APEX to control the device (start/stop, configuration updates etc.). Software System requirements Computer requirements Supported Operating systems Windows 10 (64 bit, x64-based) Available ports USB-A port (2.0 or higher) Driver installation Windows:
latest version of The https://www.tmsi.com/support/. Follow the installers instructions accordingly. the device driver can be downloaded from Page 19 of 38 USER MANUAL APEX Application Software Different types of application software are provided with APEX. APEX User Application The APEX User Application provides a Graphical User Interface to configure and control APEX in an intuitive manner. All device-related functionality is embedded in this application. Refer to the documentation provided with the application software for more information. TMSi Python Interface (Windows) TMSi has developed an language to
(www.python.org) that supports APEX. The interface can be downloaded free of charge on the TMSi website (www.tmsi.com/support) or directly from GitLab
(https://gitlab.com/tmsi/tmsi-python-interface/). the Python programming interface The TMSi Python Interface can be used to configure APEX and stream data to your PC or process the data online in Python. The set of supported features may grow over time. Refer to the documentation provided with the Python interface for more information. Wearability Secure APEX to the subject APEX can be worn by a subject by placing APEX in a dedicated cradle, that supports APEX to be worn close to the body. The backside of the cradle allows for the positioning of one or two straps, so that APEX can be worn on multiple places on the body. See the figure below for the positioning of APEX in the cradle. Page 20 of 38 USER MANUAL APEX APEX in an ME system In case APEX is connected to other electrical equipment such as a charger or a personal computer, APEX is considered to be part of a ME system. The electrical safety depends on this other equipment as stated in the IEC 60601-1 requirements for basic safety and essential performance. Please note the following aspects when using APEX in a ME system:
to If APEX is connected to a computer, the computer and the monitor should be powered from an IEC 60601-1 certified separating transformer. A network the PC, should also be connected with a cable, connected separating/isolator device. This is especially true if the computer is to be placed inside the patient environment. When the computer is placed outside the patient environment, IEC 60601-1 separating devices should be used in order to prevent an excessive leakage current originating from the USB connector shield. Do not connect an additional multiple socket-outlet or an extension cable to the separating transformer. If the computer is a laptop, an IEC 60601-1 certified power adapter for powering the laptop can be used as an alternative to the separating transformer. The internal batteries of APEX can be charged from the USB port of a computer. For fast charging, it is advised to connect APEX to a charging USB port. APEX regulates the charging current according to the available USB bus power. Although it is possible to charge APEX with a dedicated IEC 60601-1 certified USB charger adapter, this should not be done while doing a
(wireless data) measurement because of the possibility of increased mains signal interference. Page 21 of 38 USER MANUAL APEX 5 PERFORM A MEASUREMENT APEX supports a variety of usage scenarios:
Streaming data in stationary use (chapter 5.1). Previewing data in portable setting via wireless connection (chapter 5.2). Card recording without data streaming (chapter 5.3). Perform Stationary Measurement In a stationary measurement the data acquisition PC and measurement device are at a fixed place and do not move throughout the session. APEX rests on its rubber feet. Advantages Maximum data throughput. Most reliable data transmission. Simultaneous charging during use. Disadvantages Limited freedom of movement for subject. When a USB cable is connected, a connection to the device can always be opened over the USB interface if no BT connection is active. Perform Portable Measurement using Bluetooth In the portable measurement setup, APEX is not connected to a PC. The portable setup uses Bluetooth for wireless data transmission to the BT Dongle, that is inserted into the PC. The wireless setup is optimal for usage scenarios where freedom of movement is an important requirement, whilst the researcher may still monitor the incoming data. Please note that successful wireless data transmission can never be guaranteed. The amount of transmitted data is reduced by downsampling the data to half the selected sampling frequency. After completing a measurement, the full recordings
(at the original sampling rate) can be retrieved from the on-board memory. Factors that influence wireless transmission are:
Other wireless networks (or RF devices such as smartphones, tablets). Electrical equipment (especially consider microwave ovens) in the vicinity of the APEX. The line of sight between APEX and BT Dongle. Metals and human beings tend to reflect or absorb some of the wireless signals. Page 22 of 38 USER MANUAL APEX Pairing of BT Dongle and APEX The BT Dongle acts as an access point for APEX. The Dongle and APEX need to be paired by exchanging Bluetooth addresses. Application software provides the method to do so, together with a pairing confirm using the Event marker button. To do so, APEX BT interface needs to be enabled. After that, the BT Dongle can be used to search for available APEX devices and may start a pairing procedure when it finds an unpaired device. Data logging Data is always logged on APEXs on-board memory in wireless recordings, making it available for download after a recording. Perform Card recordings In card recording setups, APEX is used as a data logger without the function of data streaming. Typically, this is a use scenario where it is not necessary to process or monitor the incoming data during a recording. The data is logged and can be downloaded from the on-board memory afterwards. Measurement Configuration A card recording can be tailored to your needs via the application software interface. The latest used device configuration is used for the recording. Start/stop using the Recording button The button on APEX marked with a Recording icon can be used to start and stop a card recording. Press and hold the button for 0.1 seconds to start recording. Press and hold for 1.5 seconds again to stop the recording. After powering the device, the Recording button can be used after approximately 5 seconds. The Recording button cant be used when there is an active connection between APEX and a PC. Start/stop using recording time In some use scenarios, the recording should start and stop at a specific moment in time. The start and stop recording times can be configured via the application software interface. The time of APEX can be synchronised to the time of the PC when APEX is connected to a PC. The device will start automatically when the start recording time is reached, even when it was powered down. You can always access, retrieve and, when necessary, modify the configuration when you connect APEX via USB to the PC. A recording can be forced to stop by holding the Recording button for eight seconds. Downloading measurement data from APEX After the card recording is finished, the data can be retrieved via application software. The recordings can be downloaded and stored on the PC for further analysis. Depending on the configuration and length of the card recording, downloading all data may take a few minutes. In the meantime, the product cannot be used for other Page 23 of 38 USER MANUAL APEX measurements. APEX should be connected to a PC via a USB cable. Up to 50 card recordings can be present on the internal memory. Impedance Measurement APEX can be switched to impedance mode. In impedance mode the user can measure the electrode contact quality of all channels, including that of the Patient Ground electrode. The impedance mode is activated via the application software interface. The impedance value ranges from 0 k to 1000 k and is an indication of electrode contact quality, where lower values indicate better electrode contact. If the impedance measurement indicates 1000 k as value, there is no contact between skin and the electrode or the impedance is larger than 1000 k. When the PGND electrode is not connected, all channels display a value of 1000 k. Please note that if youre using a custom reference (other than all channels), that you prepare at least one of the reference channels before continuing with other channels. APEX can also perform an impedance measurement in parallel to an active data measurement (live impedance). It does so at the same sampling frequency as the data is sampled with. Furthermore, the Cap status indicator allows for checking the real-time impedance value against a user-configurable threshold so that a warning can also be seen when APEX is not used in combination with application software. The impedance limit may be set between 10 and 100 k. This limit is only checked for channels in the reference set, as poor connection quality in these channels may result in decreased signal quality in all other channels. Please note that the live impedance values are indicative for the quality during a measurement; the values are recorded at a different impedance frequency measurement, resulting in lower values for the live impedance measurement. the conventional than If electrodes do not make good contact, effects that may appear are increase of noise, mains interference (50/60 Hz) or impedance values that toggle around the edge of connection/disconnection. Status Events There are three status channels, two cycling status channels that display relevant device information, and one more general-purpose status channel that contains less frequent changing device information. The metadata of the cycling status channel
(CYCL_IDX) shows which information is available at the checked sample. The channel STATUS can record several events. These events may be user triggered or triggered by the device itself. The events are used to provide information about what happened with the device during recordings. The trigger input data is also stored in this channel. The following status events are available. Status Event Origin Bit # Meaning Marker event User 0 0 = No marker event 1 = Event marker button pressed Page 24 of 38 USER MANUAL APEX Status Event Origin Bit # Meaning Trigger event
(#1) Trigger Trigger event
(#2) Trigger Trigger event
(#3) Trigger Trigger event
(#4) Trigger 1 2 3 4 0 = Trigger event registered on bit 1. 1 = No trigger event registered on bit 1. 0 = Trigger event registered on bit 2. 1 = No trigger event registered on bit 2. 0 = Trigger event registered on bit 3. 1 = No trigger event registered on bit 3. 0 = Trigger event registered on bit 4. 1 = No trigger event registered on bit 4. User 5 Average Reference removal 0 = Reference removal is not enabled. 1 = Reference removal is enabled. 6 ... 14 Reserved for future use. Battery low Device 15 0 = Battery not low. 1 = Battery low (needs charging). The bits in column Bit # are numbered 0 to 15, for the least to most significant bits respectively. Depending on the application software used, they may show to be numbered 1 to 16 respectively. Event marker Button The Event marker button on the device can be used to set a Marker event in the Trigger channel. This Marker event is sampled synchronously to the other data. Typical use of this button is to mark a specific event during a card recording, so that this event can be detected afterwards. Trigger input APEX four trigger bits information are stored on the devices STATUS channel. The trigger inputs are binary inputs that are stored sample synchronous to the recorded EEG data, using negative logic as described in chapter 3.6 and outlined in the table above. Battery low APEX runs on internal batteries. When the battery charge is low, APEX logs an event. At this point, APEX should be connected to an external power supply. When the batteries run empty, APEX will close any running data acquisition session and power down. Page 25 of 38 USER MANUAL APEX 6 OPERATIONAL PRINCIPLES APEX APEX is an amplifier for EEG measurements designed for optimal signal quality. The APEX amplifier is characterised by low input noise, high input impedance and high common mode rejection. It is a true DC reference amplifier with high resolution. It uses active signal shielding to minimise electrode cable capacitance and thereby minimises cable movement artefacts and sensitivity interference
(50/60 Hz). to mains APEX is an amplifier specifically developed with EEG applications in mind; it offers both wireless and wired setups, at a sampling frequency of 1000 or 1024 Hz. Furthermore, a 4-bits trigger interface is available, so that events can be logged and studies on event-related potentials can be performed with ease. For a full list of
(technical) specifications, please refer to chapter 9. The unipolar channels of APEX are configured as an Average Reference amplifier, where all channels are included in the reference. The user is allowed to configure which channels are used as reference channels. Application software installed on the computer controls the APEX measurement functions. Unipolar input channels The input stage for measuring unipolar electrophysiological signals is configured as an Average Reference amplifier. All signals are amplified against the average of all connected unipolar inputs. Inputs that are not connected to an electrode are automatically switched off. These channels will show an overflow value. Reference The device is always configured as an average reference amplifier. However, when only a single channel is selected to make up the reference, the configuration is essentially a common reference amplifier. Another advantage of selecting your own reference channels is that you may decide to exclude channels that are prone to introduce artefacts, such as eye blinks on pre-frontal electrodes, from your reference signal. This allows for a versatile measurement setup. Active signal shielding All electrode cables are shielded with the electrode signal itself (active shielding). The active shielding ensures that disturbances such as cable movement artefacts and mains interference (50/60 Hz) are reduced to a minimum. There are no notch filters built into the device. Page 26 of 38 USER MANUAL APEX Tips for obtaining optimal quality data Placement of device Mains interference (50/60 Hz) is coming from external sources. This can be many things. It is a common mistake to state that battery powered devices are not susceptible to mains interference and devices powered from mains are. Mains interference can get into your measurement system via multiple ways, for example from other electrical equipment close by. Optimal placement of systems will increase the quality of the acquired data. Patient Ground connection TMSi recommends to use a saline wetted wristband, or to clean/prepare the skin as good as possible for optimal skin contact when using electrode patches as Patient Ground electrode. Preferably, the Patient Ground electrode is not too close (within
~5cm) to the measurement electrodes. Higher Patient Ground electrode impedance may cause more mains interference in all measurement electrodes. Electrode materials APEX is a DC-coupled amplifier with a high input range of +/-150 mV. This is more than sufficient for common measurement setups. The skin-electrode interface acts as a battery which causes a DC-shift in the signal of several millivolts up to a few hundred. If all electrodes, including Patient Ground, are made of the same material, this will not be a problem at all. If materials are mixed (for example gold electrodes or platinum electrodes are used in combination with Ag/AgCl electrodes), the DC shift can cause out-of-range channels. Different electrode materials have different DC characteristics. Some materials may drift a lot, whereas others are fairly stable over time. TMSi recommends Ag/AgCl, as it is known to be a very DC-stable material and is used in most of the commercially available electrodes for contacting intact skin. Electrode movement artefacts When cables pull on the electrode, this is visible in the data as a DC-shift, because of the change in skin-electrode interface. This can be prevented by making a strain relief loop in the cabling. If for some reason the cable is pulled, the strain relief prevents that the cable also pulls on the electrode, causing artefacts. Cable movement in itself is not a problem thanks to APEXs active shielding technology. Re-referencing/Artefacts If during a measurement an electrode is causing artefacts in the data it may be necessary to exclude this electrode from the measurement data. In Average Reference mode APEX measures its signals against the average of all configured electrodes. This means that if an electrode becomes disconnected, this electrode is immediately taken out of the average calculation. Re-referencing is needed when a channel needs to be removed from the measurement set completely. Page 27 of 38 USER MANUAL APEX 7 MAINTENANCE Servicing and Updates The product does not contain user serviceable parts. Maintenance is limited to cleaning at user discretion. Repairs can only be performed by the manufacturer, contact support@tmsi.com in case the product needs to be repaired. TMSi Support staff will determine whether a repair is required and possible. The product does not require regular servicing or re-calibration during its expected service life. Bug fixes or improvements to the firmware may become available for download from the website (www.tmsi.com). Such updates can be performed by the user. Follow the instructions accompanied with the update package carefully. Not complying with these instructions may cause the device to become unusable. Cleaning instructions Before cleaning, make sure the product is switched off and not in contact with a subject. Use only tap water, with a mild detergent if necessary, applied through a soft damp cloth. Do not spill fluids or submerge the product in liquids. Do not use sharp tools or aggressive chemicals for cleaning or disinfecting. The product surface can be disinfected with disinfection wipes based on 70% isopropyl alcohol. Other disinfectants may damage the product. Never use chlorine-based disinfection products. Do not sterilise the product. Disposal instructions Environmental protection Special EU instructions for disposal are applicable to a product on which this symbol is placed. These instructions apply to all parts of the product. When the product has reached End of Life, it must not be disposed of with other waste. Instead, it is the users responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can dispose of your waste equipment for recycling, please contact your local city office, your household waste disposal service, or TMSi. Page 28 of 38 USER MANUAL APEX 8 ELECTROMAGNETIC GUIDANCE Degradation of performance Electromagnetic disturbances, such as electrostatic discharge, mains supply overvoltage spikes and mains interruptions may cause the following types of degradation of performance:
Noticeable artefacts on signals. These should be discarded because they are clearly non-physiological signal traits. Transient interruptions of signal data communication; in extreme cases, cessation of data communication. Data does not appear on screen, but signal acquisition continues and signal data is recorded on the devices on-
board memory. As a result, the APEX product may need to be reset (recycle power). Basic safety is not affected by these phenomena. To prevent electrostatic discharges, relocate the measurement to an environment with anti-static floor and furniture and/or do not unnecessarily touch product parts. Further guidance can be found in the tables on the following pages. Portable and mobile RF communications equipment can affect the performance of the APEX product by:
Disturbing data communication within the product. This may cause loss of measurement data for real-time processing or display on the PC. The data can be retrieved from the on-board memory. Increasing noise level on signals, large offset shifts or causing signal distortion in extreme cases. Basic safety is not affected by these phenomena. To minimize their interference, keep portable and mobile RF communications equipment at sufficient distance from the product. The product needs special precautions regarding EMC and must be installed and put into service according to the EMC information outlined on the next pages. Electromagnetic emission Guidance and manufacturers declaration electromagnetic emissions The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment guidance RF emissions EN 55011 Group 1 The product uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions EN 55011 Class B APEX is suitable for use in all establishments, including domestic establishments and those directly Page 29 of 38 USER MANUAL APEX Harmonic emissions IEC 61000-3-2 Voltage fluctuations / flicker emissions IEC 61000-3-3 Class B Complies connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Electromagnetic immunity Guidance and manufacturers declaration electromagnetic immunity The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity test IEC 60601-1-2 test level Electrostatic discharge
(ESD) IEC 61000-4-2 8 kV contact 15 kV air Complian ce level 8 kV 15 kV Radiated RF EM fields IEC 61000-4-3 10 V/m
(80 to 2 700) MHz 80 % AM at 1 kHz 10 V/m Electromagnetic environment guidance Degradation of performance may occur:
Electrostatic discharges may result in air sparks at connectors coincident with signal loss. Sometimes a measurement restart is required. For further information refer to chapter 8.1. Floors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Degradation of performance may occur:
Electromagnetic radiation may distort and disturb acquired signals. At some frequencies the live communication link may be interrupted and sometimes a measurement restart is required. For further information refer to chapter 8.1. Page 30 of 38 USER MANUAL APEX Guidance and manufacturers declaration electromagnetic immunity The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity test IEC 60601-1-2 test level Proximity fields from RF wireless communication s equipment IEC 61000-4-3 27 V/m At 385 MHz, 1.8 W, 18 Hz pulse modulation 28 V/m At 450 MHz, 2 W, 1 kHz sine FM modulation with 5 kHz deviation 9 V/m At 710 MHz, 745 MHz and 780 MHz, 0.2 W, 217 Hz pulse modulation 28 V/m At 810 MHz, 870 MHz and 930 MHz, 2 W, 18 Hz pulse modulation 28 V/m At 1 720 MHz, 1 845 MHz and 1 970 MHz, 2 W, 217 Hz pulse modulation 28 V/m At 2 450 MHz, 2 W, 217 Hz pulse modulation 9 V/m At 5 240 MHz, 5 500 MHz and 5 785 MHz, 0.2 W, 217 Hz pulse modulation Electrical fast transients /
burst IEC 61000-4-4 2 kV 100 kHz repetition frequency for power supply lines1 kV for input/output lines Surges IEC 61000-4-5 1 kV Line-to-line 2 kV Line-to-ground Complian ce level 27 V/m 28 V/m 9 V/m 28 V/m 28 V/m 28 V/m 9 V/m 2 kV NA 1 kV NA Electromagnetic environment guidance Degradation of performance may occur:
Electromagnetic radiation may distort and disturb acquired signals. At some frequencies the live communication link may be interrupted. For further information refer to chapter 8.1. Portable and mobile RF communications equipment should be used no closer to any part of the product, including cables, than 0.3 m. Degradation of performance may occur:
Electrical transient pulses on AC mains may distort and disturb acquired signals. For further information refer to chapter 8.1. Mains power quality should be that of a typical commercial or hospital environment. Degradation of performance may occur: During surges transient signal interruptions may occur. For further information refer to chapter 8.1. Mains power quality should be that of a typical commercial or hospital environment. Page 31 of 38 USER MANUAL APEX Guidance and manufacturers declaration electromagnetic immunity The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity test IEC 60601-1-2 test level Complian ce level 3 V 6 V Electromagnetic environment guidance Degradation of performance may occur: High level conducted disturbances on AC mains may cause data communication loss, on other connections including subject connections they may cause transient signal interruptions. For further information refer to chapter 8.1. 3 V 1
(0.15 to 80) MHz 80 % AM at 1 kHz 6 V 1 in ISM and amateur radio bands within (0.15 to 80) MHz 80 % AM at 1 kHz 30 A/m 50 Hz or 60 Hz N.A. 4 The product is not intended for environments with restricted access due to strong magnetic fields. 2; cycle 0 % UT At 0, 45, 90, 135, 180, 225, 270 and 315 0 % UT Mains power quality should be that of a typical commercial or hospital environment. 0 % UT 2; 1 cycle 0 % UT and 70 % UT Single phase: at 0 2; 25/30 3 cycles 0 % UT 2; 250/300 3 cycles 0 % UT The operation of the device is not interrupted because it is powered from the internal battery in case of a power interruption. As specified in ISO 7637-
2 N.A. 5 Conducted disturbances induced by RF fields IEC 61000-4-6 Rated power frequency magnetic fields IEC 61000-4-8 Voltage dips IEC 61000-4-11 Voltage interruptions IEC 61000-4-11 Electrical transient conduction along supply lines ISO 7637-2 Notes:
1. 2. 3. 4. 5. This is the R.M.S. level, before modulation is applied. UT is the A.C. mains voltage prior to application of the test level. E.g. 10/12 means 10 periods at 50 Hz or 12 periods at 60 Hz. Applies only to devices with magnetically sensitive components or circuitry. Applies only to devices intended to be powered from 12/24 V road vehicle power systems. Page 32 of 38 USER MANUAL APEX Compliance Information This device complies with part 15 of the FCC Rules and to RSS of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation Canada ICES-003 compliance statement:
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada. FCC class B Device Notice Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to Increase the separation between the equipment and receiver. which the receiver is connected. Consult the dealer or an experienced radio / TV technician for help. Page 33 of 38 USER MANUAL APEX 9 TECHNICAL SPECIFICATIONS Use the REF number on the device label to identify the device configuration. General Specifications Model REF: 95-1300-0200 APEX REF: 95-1305-0200 BT Dongle Amplifier Dongle REF Size (device only) Weight Power consumption See device label Recorder:
Dongle:
Recorder:
Dongle:
Recorder:
150 x 75 x 30 mm 70 x 25 x 10 mm 240g 16g
< 2 W on battery power
< 10 W when charging On-board storage 32 GB, non-removable Regulatory Specifications Power source Internal batteries or power supplied by PC or by using a certified USB charger. Mode of operation Continuous operation Electric shock protection Applied parts: Type BF Applied parts Refer to chapter 3.2. Accessible parts Refer to chapter 3.2. Ingress protection IP22 (APEX) Protection against particulate matter with 12.5 mm diameter and against ingress of dripping water when 15 tilted Page 34 of 38 USER MANUAL APEX Battery Battery Lithium Polymer, 3.7V, 1320 mAh, non-removable Power Saving 10 minutes (idle, no connection to PC) Communication Recorder to PC Bluetooth Band Range Power 2.4 GHz 10 m 8 dBm Bandwidth Maximum 1 Mbit/s under ideal circumstances Modulation GFSK Standard 5.2 USB Bandwidth Maximum 480 Mbit/s Standard 2.0 Cable Type C to Type A connector (default option) or Type C to Type C connector. Length < 3 m BT Dongle Bluetooth Band Range Power 2.4 GHz 10 m 8 dBm Bandwidth Maximum 1 Mbit/s under ideal circumstances Modulation GFSK Standard 5.2 Transportation Conditions Temperature
-20 C to +60 C Humidity Pressure 15 % to 85 %, non-condensing 600 hPa to 1 100 hPa Storage Conditions Temperature 0 C to +40 C Humidity Pressure 15 % to 85 %, non-condensing 600 hPa to 1 100 hPa Page 35 of 38 USER MANUAL APEX Usage Conditions Temperature
+5 C to +40 C Humidity 15 % to 85 %, non-
condensing Pressure 700 hPa to 1 060 hPa CAP Channel Specifications Number of channels RMS noise
(0.1 to 100) Hz Input Range
(Differential Mode) Input Range
(Common Mode) 32 or 24 (depending on firmware version)
< 1 Vrms
-150 mV to +150 mV (@ 0 V common)
-2 V to +2 V (@ 0 V differential) Resolution (bits) 24 bits Resolution
(voltage)
< 20 nV Accuracy 2 %
Input impedance
> 2 G, < 1 pF Common Mode Rejection Ratio
>90 dB (@ 50/60 Hz), inputs referred to PGND Amplifier concept Average Reference amplifier, with selectable channels to set reference Shielding Individual signal shielding Supported Sampling Rates Analogue bandwidth 1024 / 1000 Hz DC to 350 Hz Impedance Mode Separate mode, including Patient Ground impedance measurement Range 0 k to 999 k, special values are:
1000 k overflow, or the channel impedance is 1000 k Accuracy 10 % of reading + 1 k Resolution 1 k Page 36 of 38 USER MANUAL APEX Synchronisation Specifications Number of inputs 4 on Recorder (TRIGGER input), Electrical Voltage range Low level High level
[V]
[V]
[V]
Current @ High
[mA]
Current @ Low
[mA]
Trigger input 0 to 3.3 2.0 0.8
-0.1 to 0.1(a)
-0.1 to 0.1(a) Notes:
(a) The input current will typically be close to 0 mA. Synchronicity Trigger input Wired
[samples]
1 Channel Overview Name Connection Remarks CAP 01 to CAP CAP 01 to CAP 24 for 24-channel variant. CAP 32 PGND PGND and CAP Channel output only available in impedance mode TRIGGER TRIGGER See chapter 5.5 CYCL_IDX Internal See chapter 5.5 CYCL_ST1 Internal See chapter 5.5 CYCL_ST2 Internal See chapter 5.5 STATUS Internal See chapter 5.5 COUNTER Internal Page 37 of 38 USER MANUAL APEX Copyright 2023 TMSi. All rights reserved. www.tmsi.com Page 38 of 38
1 | Agent Letter A for Service of Process FCC Attestation Statements Kiwa signed | Attestation Statements | 967.96 KiB | February 21 2023 |
Twente Medical Systems International BV. &
Zutphenstraat 57 info@tmsi.com IBAN: NL87 ABNA 0449 9184 59 BIC: ABNA NL 2A | mM Koy |
7575 EJ Oldenzaal -+31541534603 VAT: NLO09447040B01 CoC: 20056730 Haman Elketoprysiciogy The Netherlands www.tmsi.com U.S. Agent Designation for Service of Process
(Applicant and U.S. Agent are Separate Parties) TO:
Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification Section 2.911(d)(7) Information Designated U.S. Agent
|Company name: =i Cortech Solutions, Inc. Contact person name: Lloyd Smith Street address: 1409 Audubon Blvd, Suite BI ZIP/City/State 28403 / Wilmington / NC Telephone number: 910-362-1143 ext 202 Email address:
Signature:
Date:
bruary 11, 2023 E This letter is to confirm that we (the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant
|Company name: __| TMSi BV Grantee Code: 2A8DA Contact person name: Sake Kroondijk Street address: Zutphenstraat 57 ZIP/City/State 7575 EJ Oldenzaal NL Telephone number: +31 (0)541216643 Email address: sake. kroondijk@tmsi.com Signature: is , {
Date: A F ebruary 14, 2023 Weve got your signal
1 | AgentLetter A forServiceofProcess FCC AttestationStatements filled in | Attestation Statements | 985.17 KiB | February 21 2023 |
Twente Medical Systems International BV. &
Zutphenstraat 57 info@tmsi.com IBAN: NL87 ABNA 0449 9184 59 BIC: ABNA NL 2A | mM = |
7575 EJ Oldenzaal = +31541534603 - VAT: NLO09447040B01 CoC: 20056730 Himan Eleetrophumialogy The Netherlands www.tmsi.com U.S. Agent Designation for Service of Process
(Applicant and U.S. Agent are Separate Parties) TO:
Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification Section 2.911(d)(7) Information Signature:
Date:
ebruary 16, 2023 This letter is to confirm that we (the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant
[Company name: _| TMSiBV Grantee Code: 2A8DA Contact person name: Sake Kroondijk Street address: Zutphenstraat 57 ZIP/City/State/Countr 7575 EJ Oldenzaal NL Telephone number: +31 (0)541216643 Email address: sake.kroondijk@tmsi.com Signature: 7 Date:
Weve got your signal
1 | Covered List Attestation FCC ApplicationLetter | Attestation Statements | 906.25 KiB | February 21 2023 |
Twente Medical Systems International BV. Zutphenstraat 57 info@tmsi.com IBAN: NL87 ABNA 0449 9184 59 BIC: ABNA NL 2A I mM = |
7575 EJ Oldenzaal = +31541534603 - VAT: NLO09447040B01 CoC: 20056730 Honan Electroph@sisiogy The Netherlands www.tmsi.com Certification Application Attestation Statements TMSi BV Zutphenstraat 57 7575 EJ Oldenzaal NL Subject: FCC ID: 2A8DA-APEX01 To Whom It May Concern:
Statement for 47 CFR section 2.911(d)(5)(i TMSi BV certifies that as of the date of the application the equipment for which authorization is sought is not covered equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not covered equipment. Additional Explanation: <N/A>
Statement for 47 CFR section 2.911(d)(5 TMSi BV (the applicant) certifies that, as of the date of the filing of this application, the applicant 0 - is /&- is not ) identified on the Covered List as an entity producing covered equipment. Date: February 16, 2023 City: Oldenzaal Name : Sake Kroondijk Function: Hardware Engineer Telephone number: +31 (0)541216643 Email address: sake.kroondijk@tmsi.com Signature:
1_ The Commissions Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commissions website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes covered equipment. https:/Avww.fcc.gov/supplychain/coveredilist .
(2): For FCC it must be the Grantee Code owner or the authorized agent.
(3): double click on the appropriate box and select checked then OK Weve got your signal
1 | confidentiality | Cover Letter(s) | 939.76 KiB | February 21 2023 |
FCC, Request for non-disclosure Date: 08-Oct-2021 RF_501, Issue 9 Page 1 of 1 Company Name: TMSi BV Address: Zutphenstraat 57 City: 7575 EJ Enschede Country: NL To: Telefication B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2A8DA-APEX01 Reference number: ######
Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application:
[xX] Bill(s) of Material [X] Block Diagrams
[X] Operational Description [X] Schematic Diagrams [_] Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commissions policy, in order to comply with the marketing regulations in 47 CFR 2.803 and the importation rules in 47 CFR 2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below):
L_] Internal Photos [_] Users Manual L] Test Set-up Photos L_] External Photos Justification:
Date: 10/01/2023 Name and signature of applicant: Sake Kroondijk Notes:
1) A document or type of document can only have ONE type of confidentiality!
2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)!
The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this!
5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2023-02-21 | JAB - Part 15 Class B Digital Device | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2023-02-21
|
||||
1 | Applicant's complete, legal business name |
TMSi BV
|
||||
1 | FCC Registration Number (FRN) |
0032771073
|
||||
1 | Physical Address |
Zutphenstraat 57
|
||||
1 |
Oldenzaal, N/A
|
|||||
1 |
Netherlands
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@telefication.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2A8DA
|
||||
1 | Equipment Product Code |
APEX01
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S****** K******
|
||||
1 | Telephone Number |
+31(0********
|
||||
1 | Fax Number |
--********
|
||||
1 |
s******@tmsi.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
TMSi BV
|
||||
1 | Name |
S**** K******
|
||||
1 | Physical Address |
Zutphenstraat 57
|
||||
1 |
Oldenzaal
|
|||||
1 |
Netherlands
|
|||||
1 | Telephone Number |
31(0)********
|
||||
1 |
s******@tmsi.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
TMSi BV
|
||||
1 | Name |
P****** O********
|
||||
1 | Physical Address |
Zutphenstraat 57
|
||||
1 |
Oldenzaal
|
|||||
1 |
Netherlands
|
|||||
1 | Telephone Number |
31(0)********
|
||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | JAB - Part 15 Class B Digital Device | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Apex | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Kiwa Nederland B.V.
|
||||
1 | Name |
W******** J********
|
||||
1 | Telephone Number |
+31 8********
|
||||
1 |
d******@kiwa.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC