all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 |
|
User manual | Users Manual | 2.51 MiB | ||||
1 2 3 | Cover Letter(s) | / January 06 2016 | ||||||
1 2 3 | Cover Letter(s) | / January 06 2016 | ||||||
1 2 3 | Cover Letter(s) | / January 06 2016 | ||||||
1 2 3 | RF Exposure Info | / January 06 2016 | ||||||
1 2 3 | Cover Letter(s) | / January 06 2016 | ||||||
1 2 3 | Cover Letter(s) | / January 06 2016 | ||||||
1 2 3 | Test Report | / January 06 2016 | ||||||
1 2 3 | Test Report | / January 06 2016 | ||||||
1 2 3 | Test Setup Photos | |||||||
1 2 3 | Test Setup Photos | |||||||
1 2 3 |
|
15B DoC | Cover Letter(s) | 134.16 KiB | ||||
1 2 3 |
|
External photo | External Photos | 568.99 KiB | ||||
1 2 3 |
|
Internal photo | Internal Photos | 574.21 KiB | ||||
1 2 3 |
|
Label info | ID Label/Location Info | 507.56 KiB | ||||
1 2 3 |
|
MPE | RF Exposure Info | 471.62 KiB | ||||
1 2 3 |
|
Power of Attorney Letter | Cover Letter(s) | 61.68 KiB | ||||
1 2 3 |
|
RF report | Test Report | 1.61 MiB | ||||
1 2 3 |
|
WIFI declaration | Cover Letter(s) | 218.25 KiB |
1 2 3 | User manual | Users Manual | 2.51 MiB |
Introduction Thank you for purchasing the Ubiquiti Networks UniFiAP. This Quick Start Guide is designed to guide you through installation and includes warranty terms. Package Contents UniFi AP AC Lite Mounting Bracket Ceiling Backing Plate Flat Head Screws
(M3x50, Qty. 4) Keps Nuts
(M3, Qty. 4) Screws
(M2.9x20, Qty. 4) Screw Anchors
(M3x20, Qty. 4) 802.11ac Dual Radio Access Point Model: UAP-AC-LITE Gigabit PoE (24V, 0.5A) with Mounting Bracket Power Cord Quick Start Guide Installation Requirements CAT5/6 cable Phillips screwdriver Drill and drill bit (6 mm for wall-mounting or 3 mm for ceiling-mounting) Optional: Drywall or keyhole saw (to cut 18 mm hole for Ethernet cable feed) TERMS OF USE: All Ethernet cabling runs must use CAT5 (or above). It is the customers responsibility to follow local country regulations, including operation within legal frequency channels, output power, indoor cabling requirements, and Dynamic Frequency Selection
(DFS) requirements. 802.11ac Dual Radio Access Point Model: UAP-AC-LITE System Requirements Microsoft Windows 7/8, MacOSX, or Linux Java Runtime Environment 1.6 (or above) Web Browser: Mozilla Firefox, Google Chrome, or Microsoft Internet Explorer 8 (or above) UniFi Controller software v4.6 or higher (available at:
downloads.ubnt.com/unifi) Network Topology Requirements A DHCP-enabled network (for the AP to obtain an IP address as well as for the wireless clients after deployment) A management station running the UniFi Controller software, located either on-site and connected to the same Layer-2 network, or off-site in a cloud or NOC UAP-AC-Lite UAP-PRO REFRESH RATE 2 minutes www WAN LAN WLAN VOIP www WAN IP DNS XXX.XXX.XXX.XXX GATEWAY XXX.XXX.XXX.XXX ACTIVE CLIENTS 192 DOWN UP 0 0 LAN 0 162 0 0 0 SWITCHES USERS GUESTS DOWN UP WLAN VOIP APS USERS GUESTS DOWN UP 2 30 0 0 0 PHONES EXTENSION CALLS IN CALLS OUT 4 0 3 6 CURRENT SITE Default DASHBOARD Network Health MAP DEVICES CLIENTS CALLS STATISTICS INSIGHTS SETTINGS UAP-AC Outdoor 1G UniFi Switch On-Site Management Station or REFRESH RATE 2 minutes WLAN VOIP www WAN LAN www WAN IP DNS XXX.XXX.XXX.XXX GATEWAY XXX.XXX.XXX.XXX ACTIVE CLIENTS 192 DOWN UP 0 0 LAN 0 162 0 0 0 SWITCHES USERS GUESTS DOWN UP WLAN VOIP APS USERS GUESTS DOWN UP 2 30 0 0 0 PHONES EXTENSION CALLS IN CALLS OUT 4 0 3 6 CURRENT SITE Default DASHBOARD Network Health MAP DEVICES CLIENTS CALLS STATISTICS INSIGHTS SETTINGS O(cid:31)-Site Cloud/NOC LAN WAN UniFi Security Gateway Internet Sample Network Diagram All UniFi devices support off-site management controllers. For setup details, see the User Guide on the website:
documentation.ubnt.com/unifi Hardware Overview LED Ports Locking Notch LED Color White Status Factory default, waiting to be integrated. Flashing White Initializing. Alternating White/Blue Blue Quickly Flashing Blue Device is busy; do not touch or unplug it. This usually indicates that a process such as a firmware upgrade is taking place. Indicates the device has been successfully integrated into a network and is working properly. This is used to locate an AP. When you click Locate in the UniFi Controller software, the AP will flash. It will also display the location of the AP on the map. Steady Blue with occasional flashing Indicates the device is in an isolated state
(all WLANs are brought down until an uplink is found). Reset Button Main Port Cable Feed Locking Notch The Locking Notch will be used with the Mounting Bracket to help secure the UniFi AP. (This is described further in the Mounting Bracket section.) Main This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server. Power can be provided by the Gigabit PoE Adapter (included) or Ubiquiti Networks UniFi Switch. Reset The Reset button serves two functions for the UniFi AP:
Restart Press and release the Reset button quickly. Restore to Factory Default Settings Press and hold the Reset button for more than five seconds. Cable Feed Use the Cable Feed slot to feed the Ethernet cable along the mounting surface. Mounting Bracket Locking Tab Mounting Bracket Hardware Installation The UniFi AP can be mounted on the wall or ceiling. Perform the steps for the appropriate installation:
Wall Mount 1. Position the Mounting Bracket at the desired location on the wall with the arrow pointing up. 2. Use a pencil to mark the four mounting holes. Use a 6 mm drill bit to drill the mounting holes. Arrow Locking Tab During installation, the Locking Tab on the Mounting Bracket moves from the Initial Position to the Final Position, where the Locking Tab fits securely into the Locking Notch on the UniFi AP to help prevent theft. Initial Position Final Position 3. If your Ethernet cable feeds through the wall, then cut or drill a circle approximately 18 mm in diameter. Then feed the CAT5/6 cable through the hole. 25 mm Note: 25 mm is the distance from the center of the bottom mounting hole to the center of the cable hole. 4. Insert the Screw Anchors into the 6 mm holes. Secure the Mounting Bracket to the wall by inserting the Screws into the anchors. 6. Align the arrow on the UniFi AP with the arrow on the Locking Tab of the Mounting Bracket. Ceiling Mount 1. Remove the ceiling tile. 2. Place the Ceiling Backing Plate in the center of the ceiling tile. Mark the four mounting screw holes. 5. Insert the Flat Head Screws through the Mounting Bracket, ceiling tile, and Ceiling Backing Plate. Fasten the screws using the Keps Nuts. Then feed the Ethernet cable through the 18 mm hole. 6. Connect the Ethernet cable to the Main port. 8. Ensure that the UniFi AP is firmly seated on the Mounting Bracket. Turn the UniFi AP clockwise until it locks into place and the Locking Tab fits securely into the Locking Notch. Connecting to the PoE Adapter 1. Connect the other end of the Ethernet cable from the UniFi AP to the Ethernet port labeled POE on the Gigabit PoEAdapter. Locking Tab Arrow 5. Connect the Ethernet cable to the Main port. If the feed is along the mounting surface, feed the cable through the Cable Feed of the UniFi AP. 7. Ensure that the UniFi AP is firmly seated on the Mounting Bracket. Turn the UniFi AP clockwise until it locks into place and the Locking Tab fits securely into the Locking Notch. 3. Mark a hole approximately 18 mm in diameter for the Ethernet cable feed. 7. Align the arrow on the UniFi AP with the arrow on the Locking Tab of the Mounting Bracket. Cable Feed 25 mm Note: 25 mm is the distance from the center of the bottom mounting hole to the center of the cable hole. 4. Use a 3 mm drill bit to drill the screw holes, and cut or drill the hole for the Ethernet cable feed. Locking Tab Arrow 9. Set the ceiling tile back into place. Powering the UniFi AP The UniFi AP can be powered directly by a UniFi Switch or with the included Gigabit PoE Adapter. Connecting to a UniFi Switch Connect the other end of the Ethernet cable from the UniFi AP directly to a PoE port on the UniFi Switch. 2. Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the adapter. 3. Connect the Power Cord to the power port on the adapter. Connect the other end of the Power Cord to a power outlet. UniFi Switch Power Connection Diagram
*640-00180-02*
640-00180-02 1 3 5 7 9 11 13 15 17 19 21 222 4 6 8 10 12 14 16 18 20 22 24SPF1SPF2 Mounting the PoE Adapter (Optional) 1. Slide the PoE Mounting Bracket down to remove it from the Gigabit PoE Adapter. 2. Place the PoE Mounting Bracket at the desired location and mark the two holes. Pre-drill the holes if necessary, and then secure the bracket using two fasteners (not included). Software Installation Download and install the latest version of the UniFi Controller software at: downloads.ubnt.com/unifi Launch the software and follow the on-screen instructions. Step-by-step instructions are available in the User Guide located on our website: documentation.ubnt.com/unifi After you have installed the software and run the UniFi Installation Wizard, a login screen will appear for the UniFi Controller management interface. Enter the Admin Name and Password that you created and click Login. 3. Align the slots of the Gigabit PoE Adapter with the tabs of the PoE Mounting Bracket, and then slide the adapterdown. You can manage your wireless network and view network statistics using the UniFi Controller management interface. For information on configuring and using the UniFi Controller software, refer to the User Guide. Specifications Dimensions Weight UniFi AP AC Lite 154.5 x 154.5 x 30.15 mm
(6.08 x 6.08 x 1.19") 175 g (266 g with Mounting Kits) 6.17 oz (9.38 oz with Mounting Kits) Networking Interface
(1) 10/100/1000 Ethernet Port Buttons Antennas Wi-Fi Standards Power Method
(1) Reset to Defaults
(2) Dual-Band Antennas, 3 dBi Each 802.11 a/b/g/n/ac Passive PoE
(Pairs 4, 5+; 7, 8 Return) Power Supply 24V, 0.5A Gigabit PoE Adapter (Included) Max. Power Consumption Max. TX Power 2.4 GHz 5 GHz BSSID Wireless Security Certifications Mounting Operating Temperature Operating Humidity 6.5W 20 dBm 20 dBm Up to Four per Radio WEP, WPA-PSK, WPA-Enterprise
(WPA/WPA2, TKIP/AES) CE, FCC, IC Wall/Ceiling (Kits Included)
-10 to 70 C (14 to 158 F) 5 to 95% Noncondensing This radio transmitter (FCC: SWX-UAPACL) has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna Information: Dual-band antenna, Gain: 3 dBi Industry Canada CAN ICES-3(B)/NMB-3(B) To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. This radio transmitter (IC: 6545A-UAPACL) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna Information: Dual-band antenna, Gain: 3 dBi CAN ICES-3(B)/NMB-3(B) Pour rduire le risque dinterfrence aux autres utilisateurs, le type dantenne et son gain doivent tre choisies de faon que la puissance isotrope rayonne quivalente (PIRE) ne dpasse pas ce qui est ncessaire pour une communication russie. Cet appareil est conforme la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes:
1. Cet appareil ne peut pas provoquer dinterfrences et 2. Cet appareil doit accepter toute interfrence, y compris les interfrences qui peuvent causer un mauvais fonctionnement du dispositif. Les utilisateurs devraient galement noter que radars haute puissants sont allous comme principaux utilisateurs (cest--dire les utilisateurs de priorit) des bandes 5250-5350 MHz et 5650 5850 MHz et que ces radars pourraient causer des interfrences ou dommages aux dispositifs LAN. Cet metteur radio (IC: 6545A-UAPACL) a t approuve par Industrie Canada pour lexploitation avec lantenne types numrs ci-dessous avec le gain maximal admissible et requis limpdance de lantenne pour chaque type dantenne indiqu. Types dantenne non inclus dans cette liste, ayant un gain suprieur au gain maximal indiqu pour ce type, sont strictement interdits pour une utilisation avec cet appareil. Immdiatement suite la remarque, le fabricant doit fournir une liste de tous les types dantenne approuv pour une utilisation avec lmetteur, ce qui indique le gain maximal dantenne permis (en dBi) et requis dimpdance pour chacun. Informations dantenne: Antenne bi-bande, Gain: 3 dBi RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter, except as listed for this products certification. Les antennes utilises pour ce transmetteur doivent tre install en considrant une distance de sparation de toute personnes dau moins 20 cm et ne doivent pas tre localis ou utilis en conflit avec tout autre antenne ou transmetteur. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Alert Sign (!) Follows CE Marking Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking. RoHS/WEEE Compliance Statement English European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. Deutsch Die Europische Richtlinie 2002/96/EC verlangt, dass technische Ausrstung, die direkt am Gert und/oder an der Verpackung mit diesem Symbol versehen ist, nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt von regulrem Haushaltmll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gert und andere elektrische und elektronische Gerte ber die dafr zustndigen und von der Regierung oder rtlichen Behrden dazu bestimmten Sammelstellen zu entsorgen. Ordnungsgemes Entsorgen und Recyceln trgt dazu bei, potentielle negative Folgen fr Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgerte bentigen, wenden Sie sich bitte an die rtlichen Behrden oder stdtischen Entsorgungsdienste oder an den Hndler, bei dem Sie das Produkt erworben haben. Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturers label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. Espaol La Directiva 2002/96/CE de la UE exige que los equipos que lleven este smbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El smbolo indica que el producto en cuestin debe separarse de los residuos domsticos convencionales con vistas a su eliminacin. Es responsabilidad suya desechar este y cualesquiera otros aparatos elctricos y electrnicos a travs de los puntos de recogida que ponen a su disposicin el gobierno y las autoridades locales. Al desechar y reciclar correctamente estos aparatos estar contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas. Si desea obtener informacin ms detallada sobre la eliminacin segura de su aparato usado, consulte a las autoridades locales, al servicio de recogida y eliminacin de residuos de su zona o pregunte en la tienda donde adquiri el producto. Franais La directive europenne 2002/96/CE exige que lquipement sur lequel est appos ce symbole sur le produit et/ou son emballage ne soit pas jet avec les autres ordures mnagres. Ce symbole indique que le produit doit tre limin dans un circuit distinct de celui pour les dchets des mnages. Il est de votre responsabilit de jeter ce matriel ainsi que tout autre matriel lectrique ou lectronique par les moyens de collecte indiqus par le gouvernement et les pouvoirs publics des collectivits territoriales. Llimination et le recyclage en bonne et due forme ont pour but de lutter contre limpact nfaste potentiel de ce type de produits sur lenvironnement et la sant publique. Pour plus dinformations sur le mode dlimination de votre ancien quipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des dchets, ou lendroit o vous avez achet le produit. Italiano La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sullimballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. responsabilit del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per lambiente e per la salute dellessere umano. Per ricevere informazioni pi dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto. Limited Warranty UBIQUITI NETWORKS, Inc (UBIQUITI NETWORKS) warrants that the product(s) furnished hereunder (the Product(s)) shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation. UBIQUITI NETWORKS sole and exclusive obligation and liability under the foregoing warranty shall be for UBIQUITI NETWORKS, at its discretion, to repair or replace any Product that fails to conform to the above warranty during the above warranty period. The expense of removal and reinstallation of any Product is not included in this warranty. The warranty period of any repaired or replaced Product shall not extend beyond its original term. Warranty Conditions The above warranty does not apply if the Product:
(I) has been modified and/or altered, or an addition made thereto, except by Ubiquiti Networks, or Ubiquiti Networks authorized representatives, or as approved by Ubiquiti Networks in writing;
has been painted, rebranded or physically modified in any way;
has been damaged due to errors or defects in cabling;
has been subjected to misuse, abuse, negligence, abnormal physical, electromagnetic or electrical stress, including lightning strikes, or accident;
has been damaged or impaired as a result of using third party firmware;
has no original Ubiquiti MAC label, or is missing any other original Ubiquiti label(s); or has not been received by Ubiquiti within 30 days of issuance of the RMA.
(II)
(III)
(IV)
(V)
(VI)
(VII) In addition, the above warranty shall apply only if: the product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation; all Ethernet cabling runs use CAT5 (or above), and for outdoor installations, shielded Ethernet cabling is used, and for indoor installations, indoor cabling requirements are followed. Returns No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS during the warranty period, and the Products being received at UBIQUITI NETWORKS facility freight prepaid in accordance with the RMA process of UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned freight collect or subject to disposal. Information on the RMA process and obtaining an RMA number can be found at: www.ubnt.com/support/warranty. Declaration of Conformity esky
[Czech]
Dansk
[Danish]
Nederlands
[Dutch]
English Eesti
[Estonian]
Suomi
[Finnish]
Franais
[French]
Deutsch
[German]
[Greek]
Magyar
[Hungarian]
slenska
[Icelandic]
Italiano
[Italian]
Latviski
[Latvian]
UBIQUITI NETWORKS tmto prohlauje, e toto UBIQUITI NETWORKS zazen, je ve shod se zkladnmi poadavky a dalmi pslunmi ustanovenmi smrnice 1999/5/ES. Hermed, UBIQUITI NETWORKS, erklrer at denne UBIQUITI NETWORKS enhed, er i overensstemmelse med de vsentlige krav og vrige relevante krav i direktiv 1999/5/EF. Hierbij verklaart UBIQUITI NETWORKS, dat deze UBIQUITI NETWORKS apparaat, in overeenstemming is met de essentile eisen en de andere relevante bepalingen van richtlijn 1999/5/EC. Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI NETWORKS device, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Kesolevaga UBIQUITI NETWORKS kinnitab, et antud UBIQUITI NETWORKS seade, on vastavus olulistele nuetele ja teistele asjakohastele stetele direktiivi 1999/5/E. Tten UBIQUITI NETWORKS vakuuttaa, ett tm UBIQUITI NETWORKS laite, on yhdenmukainen olennaisten vaatimusten ja muiden sit koskevien direktiivin 1999/5/EY. Par la prsente UBIQUITI NETWORKS dclare que lappareil UBIQUITI NETWORKS, est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Hiermit erklrt UBIQUITI NETWORKS, dass sich dieses UBIQUITI NETWORKS Gert, in bereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet.
, UBIQUITI NETWORKS, UBIQUITI NETWORKS, 1995/5/. Ezennel UBIQUITI NETWORKS kijelenti, hogy ez a UBIQUITI NETWORKS kszlk megfelel az alapvet kvetelmnyeknek s ms vonatkoz 1999/5/EK irnyelv rendelkezseit. Hr, UBIQUITI NETWORKS, v yfir a etta UBIQUITI NETWORKS tki er samrmi vi grunnkrfur og nnur vieigandi kvi tilskipun 1999/5/EC. Con la presente, UBIQUITI NETWORKS, dichiara che questo dispositivo UBIQUITI NETWORKS, conforme ai requisiti essenziali ed alle altre disposizioni pertinenti della direttiva 1999/5/CE. Ar o, UBIQUITI NETWORKS, deklar, ka UBIQUITI NETWORKS ierce, ir saska ar btiskajm prasbm un citiem attiecgiem noteikumiem Direktv 1999/5/EK. Lietuvikai
[Lithuanian]
UBIQUITI NETWORKS deklaruoja, kad is UBIQUITI NETWORKS renginys atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Disclaimer EXCEPT FOR ANY EXPRESS WARRANTIES PROVIDED HEREIN, UBIQUITI NETWORKS, ITS AFFILIATES, AND ITS AND THEIR THIRD PARTY DATA, SERVICE, SOFTWARE AND HARDWARE PROVIDERS HEREBY DISCLAIM AND MAKE NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, REPRESENTATIONS, GUARANTEES, OR WARRANTIES OF MERCHANTABILITY, ACCURACY, QUALITY OF SERVICE OR RESULTS, AVAILABILITY, SATISFACTORY QUALITY, LACK OF VIRUSES, QUIET ENJOYMENT, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING, USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES. BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NETWORKS NOR ITS THIRD PARTY PROVIDERS CONTROL BUYERS EQUIPMENT OR THE TRANSFER OF DATA OVER COMMUNICATIONS FACILITIES, INCLUDING THE INTERNET, AND THAT THE PRODUCTS AND SERVICES MAY BE SUBJECT TO LIMITATIONS, INTERRUPTIONS, DELAYS, CANCELLATIONS AND OTHER PROBLEMS INHERENT IN THE USE OF COMMUNICATIONS FACILITIES. UBIQUITI NETWORKS, ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS, DELAYS, CANCELLATIONS, DELIVERY FAILURES, DATA LOSS, CONTENT CORRUPTION, PACKET LOSS, OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING. In addition, UBIQUITI NETWORKS does not warrant that the operation of the Products will be error-free or that operation will be uninterrupted. In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance, including coverage, buyers selection of products (including the Products) for buyers application and/or failure of products (including the Products) to meet government or regulatory requirements. Limitation of Liability EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN NO EVENT WILL UBIQUITI OR ITS SUBSIDIARIES, AFFILIATES OR SUPPLIERS BE LIABLE FOR DIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES
(INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS), ARISING OUT OF THE USE, INABILITY TO USE, OR THE RESULTS OF USE OF THE PRODUCT, WHETHER BASED IN WARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY, AND WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Malti
[Maltese]
Norsk
[Norwegian]
Slovensky
[Slovak]
Svenska
[Swedish]
Espaol
[Spanish]
Polski
[Polish]
Portugus
[Portuguese]
Romn
[Romanian]
Hawnhekk, UBIQUITI NETWORKS, tiddikjara li dan il-mezz UBIQUITI NETWORKS huwa konformi mar-rekwiiti essenzjali u dispoizzjonijiet rilevanti orajn ta Direttiva 1999/5/EC. Herved UBIQUITI NETWORKS, erklrer at denne UBIQUITI NETWORKS enheten, er i samsvar med de grunnleggende kravene og andre relevante bestemmelser i direktiv 1999/5/EF. Tmto UBIQUITI NETWORKS, prehlasuje, e toto UBIQUITI NETWORKS zariadenie, je v slade so zkladnmi poiadavkami a almi relevantnmi ustanoveniami smernice 1999/5/ES. Hrmed UBIQUITI NETWORKS, intygar att denna UBIQUITI NETWORKS enhet r i verensstmmelse med de vsentliga egenskapskrav och vriga relevanta bestmmelser som framgr av direktiv 1999/5/EG. Por medio de la presente UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS, cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Niniejszym, Ubiquiti Networks, owiadcza, e urzdzenie UBIQUITI NETWORKS, jest zgodny z zasadniczymi wymaganiami oraz pozostaymi stosownymi postanowieniami Dyrektywy 1999/5/EC. UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS, est conforme com os requisitos essenciais e outras disposies da Directiva 1999/5/CE. Prin prezenta, UBIQUITI NETWORKS declar c acest dispozitiv UBIQUITI NETWORKS este n conformitate cu cerinele eseniale i alte prevederi relevante ale Directivei 1999/5/CE. Online Resources Support support.ubnt.com Community community.ubnt.com Downloads downloads.ubnt.com Note Some countries, states and provinces do not allow exclusions of implied warranties or conditions, so the above exclusion may not apply to you. You may have other rights that vary from country to country, state to state, or province to province. Some countries, states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages, so the above limitation may not apply to you. EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW, THESE WARRANTY TERMS DO NOT EXCLUDE, RESTRICT OR MODIFY, AND ARE IN ADDITION TO, THE MANDATORY STATUTORY RIGHTS APPLICABLE TO THE LICENSE OF ANY SOFTWARE (EMBEDDED IN THE PRODUCT) TO YOU. The United Nations Convention on Contracts for the International Sale of Goods shall not apply to any transactions regarding the sale of the Products. Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to Increase the separation between the equipment and receiver. which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 2015 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, the Ubiquiti U logo, the Ubiquiti beam logo, and UnIFi are trademarks or registered trademarks of Ubiquiti Networks, Inc. in the United States and in other countries. All other trademarks are the property of their respective owners. AI052115
1 2 3 | 15B DoC | Cover Letter(s) | 134.16 KiB |
Attestation for FCC Declaration of Conformity Brand: UBIQUITI Model Number: UAP-AC-LITE Date: 2015/07/30 FCC ID: SWX-UAPACL Please be notified that we, Ubiquiti Networks, Inc. ,would like to declare that the composite portion categorized as computer peripheral has been authorized under the FCC Declaration of Conformity procedures. Testing in regards to this report was done by A Test Lab Techno Corp., located in No.140-1 Changan Str., Bade City Taoyuan County Taiwan, which has been accredited in accordance to all of the requirements of 47 CFR 2.948 (d) and (e) of the FCC rules and KDB349827. Sincerely, Signature :
Clients Name: Michael Taylor / Compliance Manager Company Name: Ubiquiti Networks, Inc. Address: 2580 Orchard Parkway, San Jose, California, United States 95131 TEL: 408-942-3084 FAX: 408-904-5255 MAIL: compliance@ubnt.com
1 2 3 | External photo | External Photos | 568.99 KiB |
External Photos Model Number: UAP-AC-LITE FCC ID: SWX-UAPACL 1 of 9 EUT Photo 1 ) WLAN ANT. EUT Photo 2 ) 2 of 9 EUT Photo 3 ) EUT Photo 4 ) 3 of 9 EUT Photo 5 ) EUT Photo 6 ) 4 of 9 EUT Photo 7 ) EUT Photo 8 ) 5 of 9 EUT Photo 9 ) EUT Photo 10 ) 6 of 9 EUT Photo 11 ) EUT Photo 12 ) 7 of 9 EUT Photo 13 ) EUT Photo 14 ) 8 of 9 EUT Photo 15 ) 9 of 9
1 2 3 | Internal photo | Internal Photos | 574.21 KiB |
Internal Photos Model Number: UAP-AC-LITE FCC ID: SWX-UAPACL 1 of 5 EUT Photo 1 ) EUT Photo 2 ) 2 of 5 EUT Photo 3 ) EUT Photo 4 ) 3 of 5 EUT Photo 5 ) EUT Photo 6 ) 4 of 5 EUT Photo 7 ) EUT Photo 8 ) 5 of 5
1 2 3 | MPE | RF Exposure Info | 471.62 KiB |
A Test Lab Techno Corp. Changan LabNo. 140 -1, Changan Street, Bade City, Taoyuan County, Taiwan R.O.C. Tel886-3-271-0188 / Fax886-3-271-0190 MPE Report Test Report No. Applicant Manufacturer Product Type Trade Name Model Number Date of Received Test Period Date of Issued Test Specification Location of Test Lab. Chang-an Lab. 1506FS15-02 Ubiquiti Networks,Inc. Ubiquiti Networks,Inc. Access Point UBIQUITI UAP-AC-LITE Apr. 08, 2015 Jun. 22 ~ Jun. 24, 2015 Aug. 12, 2015 47 CFR 2.1091 47 CFR 1.1310 ANSI / IEEE Std.C95.1-1992 1. The test operations have to be performed with cautious behavior, the test results are as attached. 2. The test results are under chamber environment of A Test Lab Techno Corp. A Test Lab Techno Corp. does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples. 3. The measurement report has to be written approval of A Test Lab Techno Corp. It may only be reproduced or published in full. This report shall not be reproduced except in full, without the written approval of A Test Lab Techno Corp. 4. This document may be altered or revised by A Test Lab Techno. Corp. personnel only, and shall be noted in the revision section of the document. Approved By Tested By
(Bill Hu)
(Sky Chou) 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 1 of 9 Contents 1. Description of Equipment under Test (EUT) .................................................................... 3 2. Human Exposure Assessment ........................................................................................ 4 3. RF Output Power ............................................................................................................ 5 4. Test Result ...................................................................................................................... 8 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 2 of 9 1. Description of Equipment under Test (EUT) Applicant Applicant Address Manufacturer Manufacturer Address Product Type Trade Name Model Number FCC ID Frequency Range Ubiquiti Networks,Inc. 2580 Orchard Parkway,San Jose,California,United States,95131 Ubiquiti Networks,Inc. 2580 Orchard Parkway,San Jose,California,United States,95131 Access Point UBIQUITI UAP-AC-LITE SWX-UAPACL Mode Frequency Range IEEE 802.11b / IEEE 802.11g IEEE 802.11n (2.4GHz) 20MHz IEEE 802.11n (2.4GHz) 40MHz IEEE 802.11a IEEE 802.11n (5GHz) 20MHz IEEE 802.11n (5GHz) 40MHz IEEE 802.11ac 80MHz IEEE 802.11b :
IEEE 802.11g :
IEEE 802.11n (2.4GHz) 20MHz :
IEEE 802.11n (2.4GHz) 40MHz :
IEEE 802.11a (Band I) :
IEEE 802.11a (Band III) :
IEEE 802.11n (5GHz) 20MHz (Band I) :
IEEE 802.11n (5GHz) 20MHz (Band III) :
IEEE 802.11n (5GHz) 40MHz (Band I) :
IEEE 802.11n (5GHz) 40MHz (Band III) :
IEEE 802.11ac 80MHz (Band I) :
IEEE 802.11ac 80MHz (Band III) :
2.4GHz: 3 dBi 5GHz: 3 dBi Dual band antenna 1.04 W/m2
-10 ~ +70C Transmit Power
(conducted power) Antenna Specification Antenna Designation RF Evaluation Temperature Range The above equipment was tested by A Test Lab Techno Corp. For compliance with the requirements set forth in 47 CFR 2.1091 & 47 CFR 1.1310. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties 2412 2462 MHz 2412 2462 MHz 2422 2452 MHz 5180 5240 MHz (Band I) 5745 5825 MHz (Band III) 5180 5240 MHz (Band I) 5745 5825 MHz (Band III) 5190 5230 MHz (Band I) 5755 5795 MHz (Band III) 5210 MHz (Band I) 5775 MHz (Band III) 0.057 W 17.58 dBm 0.041 W 16.17 dBm 0.042 W 16.25 dBm 0.036 W 15.62 dBm 0.080 W 19.01 dBm 0.166 W 22.19 dBm 0.080 W 19.01 dBm 0.166 W 22.21 dBm 0.090 W 19.56 dBm 0.118 W 20.72 dBm 0.081 W 19.10 dBm 0.079 W 18.95 dBm 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 3 of 9 2. Human Exposure Assessment Due to the design and installation of this product, it is not possible to conduct SAR evaluation. This is because client either manufactures or supplies the antenna(s) that will be used in the installation of this product. Therefore, this product will be evaluated as a mobile device per 47 CFR 1.1310 titled Radiofrequency radiation exposure limits, generally referred to as MPE limits. In 47 CFR 2.1091, paragraph (b) defines a mobile device as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 cm is normally maintained between the transmitters radiating structure(s) and the body of the user or nearby persons. This product is intended to be installed into a vehicle such that the unit is physically secured at one location. In the installation guide supplied with the product, Client has made the following statement: IMPORTANT: To meet the FCCs RF Exposure Guidelines, the antenna should be installed so there is at least 20 cm of separation between the body of the user and nearby persons and the antenna. Based on the installation of the transceiver and the antenna, the transmitters radiating structure is more than 20 cm from the user. Thus, this product is a mobile device as defined in section 2.1091 paragraph (b). Exposure evaluation S
=
PG 4 R 2 Where S: power density P: power input to the antenna G: power gain of the antenna in the direction of interest relative to an isotropic radiator. R: distance to the center of radiation of the antenna. 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 4 of 9 3. RF Output Power Band Data Rate CH Frequency
(MHz) Average Power
(dBm) ANT-0 ANT-1 ANT-0+1 IEEE 802.11b IEEE 802.11g IEEE 802.11n 20MHz
(2.4 GHz) IEEE 802.11n 40MHz
(2.4 GHz) 1 M 2 M 5.5 M 11 M 6 M 9 M 12 M 18 M 24 M 36 M 48 M 54 M 13 M 26 M 39 M 52 M 78 M 104 M 117 M 130 M 27 M 54 M 81 M 108 M 162 M 216 M 243 M 270 M 1 6 11 6 6 6 1 6 11 6 6 6 6 6 6 6 1 6 11 6 6 6 6 6 6 6 3 6 9 6 6 6 6 6 6 6 2412.0 2437.0 2462.0 2437.0 2437.0 2437.0 2412.0 2437.0 2462.0 2437.0 2437.0 2437.0 2437.0 2437.0 2437.0 2437.0 2412.0 2437.0 2462.0 2437.0 2437.0 2437.0 2437.0 2437.0 2437.0 2437.0 2422.0 2437.0 2452.0 2437.0 2437.0 2437.0 2437.0 2437.0 2437.0 2437.0 14.32 14.08 14.40 13.97 13.98 14.06 12.52 13.11 13.16 12.99 13.06 13.08 12.85 12.82 12.93 13.10 12.67 12.99 12.70 12.91 12.86 12.69 12.13 12.17 12.20 12.24 12.11 12.37 12.06 12.14 12.21 11.10 11.45 11.16 11.01 10.80 14.81 14.65 13.96 14.17 14.05 14.03 12.57 13.18 13.15 13.17 13.15 13.13 12.92 13.05 12.89 13.16 12.95 13.47 13.42 13.43 13.46 13.22 12.98 12.84 12.87 12.75 12.31 12.83 12.58 12.73 12.74 12.71 12.06 11.81 11.77 11.49 17.58 17.38 17.20 17.08 17.03 17.06 15.56 16.16 16.17 16.09 16.12 16.12 15.90 15.95 15.92 16.14 15.82 16.25 16.09 16.19 16.18 15.97 15.59 15.53 15.56 15.51 15.22 15.62 15.34 15.46 15.49 14.99 14.78 14.51 14.42 14.17 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 5 of 9 Band Date Rate CH Frequency
(MHz) IEEE 802.11a IEEE 802.11a
(5GHz) 20MHz 6 M 54 M 26 M 260 M 36 40 44 48 149 153 157 161 165 36 40 44 48 149 153 157 161 165 36 40 44 48 149 153 157 161 165 36 40 44 48 149 153 157 161 165 5180.0 5200.0 5220.0 5240.0 5745.0 5765.0 5785.0 5805.0 5825.0 5180.0 5200.0 5220.0 5240.0 5745.0 5765.0 5785.0 5805.0 5825.0 5180.0 5200.0 5220.0 5240.0 5745.0 5765.0 5785.0 5805.0 5825.0 5180.0 5200.0 5220.0 5240.0 5745.0 5765.0 5785.0 5805.0 5825.0 Average Conducted power ANT-0 15.72 15.61 15.48 15.79 17.97 18.05 18.21 17.78 17.83 15.68 15.59 15.32 15.73 17.88 18.01 18.08 17.46 17.59 15.74 15.71 15.61 15.67 17.86 18.15 18.24 18.00 18.02 15.62 15.63 15.47 15.52 17.81 18.03 18.19 17.78 17.97
(dBm) ANT-1 16.15 16.18 16.25 16.20 19.48 19.63 19.97 19.65 19.66 16.13 16.07 16.18 16.09 19.33 19.55 19.72 19.38 19.58 16.07 16.17 16.24 16.30 19.80 19.67 19.99 19.80 19.69 15.75 15.71 15.88 16.12 19.61 19.55 19.78 19.68 19.52 ANT-0+1 18.95 18.91 18.89 19.01 21.80 21.92 22.19 21.83 21.85 18.92 18.85 18.78 18.92 21.68 21.86 21.99 21.54 21.71 18.92 18.96 18.95 19.01 21.95 21.99 22.21 22.00 21.95 18.70 18.68 18.69 18.84 21.81 21.87 22.07 21.84 21.82 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 6 of 9 Band Date Rate CH Frequency
(MHz) IEEE 802.11a
(5GHz) 40MHz IEEE 802.11ac 80MHz 54 M 540 M 58.6 M 780 M 38 46 151 159 38 46 151 159 42 155 42 155 5190.0 5230.0 5755.0 5795.0 5190.0 5230.0 5755.0 5795.0 5210.0 5775.0 5210.0 5775.0 Average Conducted power ANT-0 16.29 16.31 16.74 16.66 15.72 15.93 16.22 16.39 16.06 15.12 15.60 14.98
(dBm) ANT-1 16.48 16.77 18.21 18.55 15.53 16.48 17.83 18.29 16.12 16.63 15.93 16.41 ANT-0+1 19.40 19.56 20.55 20.72 18.64 19.22 20.11 20.45 19.10 18.95 18.78 18.76 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 7 of 9 4. Test Result Band Data Rate Frequency
(MHz) Limit
(mw) Distance
[R]
(cm) IEEE 802.11b 1M IEEE 802.11g 6M IEEE 802.11n
(2.4GHz) 20MHz IEEE 802.11n
(2.4GHz) 40MHz 13M 27M IEEE 802.11a 6M IEEE 802.11n
(5GHz) 20MHz 26M IEEE 802.11n
(5GHz) 40MHz 54M 2412 2437 2462 2412 2437 2462 2412 2437 2462 2422 2437 2452 5180 5200 5220 5240 5745 5765 5785 5805 5825 5180 5200 5220 5240 5745 5765 5785 5805 5825 5190 5230 5755 5795 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Max tune-up Power
(upper limit)
[P] (dBm) 18 18 18 17 17 17 17 17 17 16 16 16 20 20 20 20 23 23 23 23 23 20 20 20 20 23 23 23 23 23 20 20 22 22 ANT Gain
(dBi) Numeric Gain
[G] (dBi) Duty Cycle 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Note: The Numeric Gain calculated by 10^(ant. Gain(dBi) /10).
[P] x [G]
with Duty cycle
[TP]
(mW) 126.19 126.19 126.19 100.24 100.24 100.24 100.24 100.24 100.24 79.62 79.62 79.62 200.00 200.00 200.00 200.00 399.05 399.05 399.05 399.05 399.05 200.00 200.00 200.00 200.00 399.05 399.05 399.05 399.05 399.05 200.00 200.00 316.98 316.98 Power Density
[S]
(mw)/cm^2 0.025 0.025 0.025 0.020 0.020 0.020 0.020 0.020 0.020 0.016 0.016 0.016 0.040 0.040 0.040 0.040 0.079 0.079 0.079 0.079 0.079 0.040 0.040 0.040 0.040 0.079 0.079 0.079 0.079 0.079 0.040 0.040 0.063 0.063 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 8 of 9 Band Data Rate Frequency
(MHz) Limit
(mw) Distance
[R]
(cm) Max tune-up Power
(upper limit)
[P] (dBm) ANT Gain
(dBi) Numeric Gain
[G] (dBi) Duty Cycle IEEE 802.11ac 80MHz 58.6M 5210 5775 1 1 20 20 21 20 3 3 2 2 1 1 Note: The Numeric Gain calculated by 10^(ant. Gain(dBi) /10). Simultaneous Transmitting:
Simultaneous MPE = 2.4GHz MPE+5GHz MPE = 0.025+0.079=0.104 mw/cm^2
[P] x [G]
with Duty cycle
[TP]
(mW) 251.79 200.00 Power Density
[S]
(mw)/cm^2 0.050 0.040 2015 A Test Lab Techno Corp. Report Number: 1506FS15-02Page 9 of 9
1 2 3 | Power of Attorney Letter | Cover Letter(s) | 61.68 KiB |
Tel: 408-526-1188 Fax: 408-526-1088 Email: TCB@siemic.com 775 Montague Expressway Milpitas, CA 95035 Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Initial Release (obsolete) Revised wording (obsolete) Updated company template (obsolete) Updated letter information (obsolete) Added FCC ID field (current) Revision History To 1.0 2.0 3.0 4.0 5.0 From 1.0 1.0 2.0 3.0 4.0 Approved Date Nov-14-2006 Sept25-2007 Jan-31-2012 May-23-2014 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 Date : 2015/07/30 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Ubiquiti Networks, Inc. hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s):
Product description: Access Point Model Number: UAP AC LITE FCC ID: SWX-UAPACL Sincerely, Signature :
Clients Name: Michael Taylor / Compliance Manager Company Name: Ubiquiti Networks, Inc. Address: 2580 Orchard Parkway, San Jose, California, United States 95131 TEL: 408-942-3084 FAX: 408-904-5255 MAIL: compliance@ubnt.com SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0
1 2 3 | RF report | Test Report | 1.61 MiB |
FCC 47 CFR PART 15 SUBPART C RF Test Report Applicant Ubiquiti Networks,Inc. Applicant Address 2580 Orchard Parkway,San Jose,California,United States,95131 Product Type Access Point Trade Name UBIQUITI Model Number UAP-AC-LITE Applicable Standard FCC 47 CFR PART 15 SUBPART C: Oct., 2014 Receive Date Apr. 08, 2015 ANSI C63.10:2013 Test Period Jun. 02 ~ 26, 2015 Issue Date Aug. 04, 2015 Issue by A Test Lab Techno Corp. No. 140-1, Changan Street, Bade City, Taoyuan County 334, Taiwan R.O.C. Tel+886-3-2710188 / Fax+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Note: This report shall not be reproduced except in full, without the written approval of A Test Lab Techno Corp. This document may be altered or revised by A Test Lab Techno Corp. personnel only, and shall be noted in the revision section of the document. The client should not use it to claim product endorsement by TAF, or any government agencies. The test results in the report only apply to the tested sample. Report Number: 1506FR271 of 88 A Test Lab Techno Corp. Rev. 00 Revision History Issue Date Aug. 04, 2015 Initial Issue Revisions Revised By Report Number: 1506FR272 of 88 A Test Lab Techno Corp. Applicant Address Applicant Product Type Trade Name Model Number FCC ID Verification of Compliance Issued Date: 08/04/2015
: Ubiquiti Networks,Inc.
: 2580 Orchard Parkway,San Jose,California,United States,95131
: Access Point
: UBIQUITI
: UAP-AC-LITE
: SWX-UAPACL EUT Rated Voltage
: DC 24V, 0.5A Test Voltage Applicable Standard
: 120 Vac / 60 Hz
: FCC 47 CFR PART 15 SUBPART C: Oct., 2014 ANSI C63.10:2013 Test Result Performing Lab.
: Complied
: A Test Lab Techno Corp. No. 140-1, Changan Street, Bade City, Taoyuan County 334, Taiwan R.O.C. Tel+886-3-2710188 / Fax+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 http://www.atl-lab.com.tw/e-index.htm A Test Lab Techno Corp. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by A Test Lab Techno Corp. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Approved By Reviewed By
(Manager)
(Fly Lu)
(Testing Engineer)
(Eric Ou Yang) Report Number: 1506FR273 of 88 A Test Lab Techno Corp. TABLE OF CONTENTS 1 General Information....................................................................................................................................... 6 2 EUT Description ............................................................................................................................................. 7 3 Test Methodology .......................................................................................................................................... 8 3.1. Mode of Operation.................................................................................................................................. 8 3.2. EUT Exercise Software ........................................................................................................................ 12 3.3. Configuration of Test System Details ................................................................................................... 13 3.4. Test Site Environment .......................................................................................................................... 14 4 Conducted Emission Measurement ........................................................................................................... 15 4.1. Limit ...................................................................................................................................................... 15 4.2. Test Instruments ................................................................................................................................... 15 4.3. Test Setup............................................................................................................................................. 15 4.4. Test Procedure ..................................................................................................................................... 16 4.5. Test Result............................................................................................................................................ 17 5 Radiated Emission Measurement............................................................................................................... 19 5.1. Limit ...................................................................................................................................................... 19 5.2. Test Instruments ................................................................................................................................... 19 5.3. Setup .................................................................................................................................................... 20 5.4. Test Procedure ..................................................................................................................................... 22 5.5. Test Result............................................................................................................................................ 24 6 Maximum Conducted Output Power Measurement.................................................................................. 32 6.1. Limit ...................................................................................................................................................... 32 6.2. Test Setup............................................................................................................................................. 32 6.3. Test Instruments ................................................................................................................................... 32 6.4. Test Procedure ..................................................................................................................................... 32 6.5. Test Result............................................................................................................................................ 33 7 6dB RF Bandwidth Measurement............................................................................................................... 37 7.1. Limit ...................................................................................................................................................... 37 7.2. Test Setup............................................................................................................................................. 37 7.3. Test Instruments ................................................................................................................................... 37 7.4. Test Procedure ..................................................................................................................................... 37 7.5. Test Result............................................................................................................................................ 38 7.6. Test Graphs .......................................................................................................................................... 39 8 Maximum Power Density Measurement .................................................................................................... 47 8.1. Limit ...................................................................................................................................................... 47 8.2. Test Setup............................................................................................................................................. 47 8.3. Test Instruments ................................................................................................................................... 47 8.4. Test Procedure ..................................................................................................................................... 47 8.5. Test Result............................................................................................................................................ 48 8.6. Test Graphs .......................................................................................................................................... 49 Report Number: 1506FR274 of 88 A Test Lab Techno Corp. 9 Out of Band Conducted Emissions Measurement ................................................................................... 57 9.1. Limit ...................................................................................................................................................... 57 9.2. Test Setup............................................................................................................................................. 57 9.3. Test Instruments ................................................................................................................................... 57 9.4. Test Procedure ..................................................................................................................................... 57 9.5. Test Graphs .......................................................................................................................................... 58 10 Band Edges Measurement .......................................................................................................................... 82 10.1. Limit ...................................................................................................................................................... 82 10.2. Test Setup............................................................................................................................................. 82 10.3. Test Instruments ................................................................................................................................... 82 10.4. Test Procedure ..................................................................................................................................... 83 10.5. Test Result............................................................................................................................................ 84 11 Antenna Measurement................................................................................................................................. 88 11.1. Limit ...................................................................................................................................................... 88 11.2. Antenna Connector Construction ......................................................................................................... 88 Report Number: 1506FR275 of 88 A Test Lab Techno Corp. 1 General Information 1.1 Summary of Test Result Standard 15.247 15.207
-----
Standard 15.247 15.247(d) 15.247(b)(3) 15.247(a)(2) 15.247(e) 15.247(d) 15.247(d) 15.203 Item Result Remark AC Power Conducted Emission 99 % Occupied Bandwidth PASS PASS
-----
-----
Item Result Remark Transmitter Radiated Emissions PASS Max. Output Power 6dB RF Bandwidth Power Spectral Density Out of Band Conducted Spurious Emission Band Edge Measurement Antenna Requirement PASS PASS PASS PASS PASS PASS
-----
-----
-----
-----
-----
-----
-----
The test results of this report relate only to the tested sample(s) identified in this report. Manufacturer or whom it may concern should recognize the pass or fail of the test result. 1.2 Measurement Uncertainty Test Item Conducted Emission Frequency Range 9kHz ~ 30MHz 30MHz ~ 1000MHz Radiated Emission 1000MHz ~ 18000MHz 18000MHz ~ 40000MHz Horizontal Vertical Horizontal Vertical Horizontal Vertical Uncertainty (dB) 2.02 3.98 3.62 3.11 3.07 3.66 3.54 Report Number: 1506FR276 of 88 A Test Lab Techno Corp. 2 EUT Description Applicant Ubiquiti Networks,Inc. Applicant Address 2580 Orchard Parkway,San Jose,California,United States,95131 Manufacturer Ubiquiti Networks,Inc. Manufacturer Address 2580 Orchard Parkway,San Jose,California,United States,95131 Product Type Trade Name Model Number FCC ID Operate Band Frequency Range Modulation Type Channel Numbers Antenna Delivery Antenna Type Antenna Gain RF Output Power Access Point UBIQUITI UAP-AC-LITE SWX-UAPACL IEEE 802.11b / 802.11g / 802.11n 2.4GHz 20MHz & 40MHz IEEE 802.11b / 802.11g / 802.11n 2.4GHz 20MHz: 2412 ~ 2462 MHz IEEE 802.11n 2.4GHz 40MHz: 2422 ~ 2452 MHz IEEE 802.11b:DSSS IEEE 802.11g:DSSS + OFDM IEEE 802.11n 2.4GHz 20MHz: OFDM IEEE 802.11n 2.4GHz 40MHz: OFDM IEEE 802.11b / 802.11g / 802.11n 2.4GHz 20MHz: 11ch IEEE 802.11n 2.4GHz 40MHz: 9ch 2TX + 2RX Dual band antenna 3 dBi IEEE 802.11b: 0.110 W /20.43 dBm IEEE 802.11g: 0.080 W / 19.04 dBm IEEE 802.11n 2.4GHz 20MHz: 0.082 W / 19.13 dBm IEEE 802.11n 2.4GHz 40MHz: 0.071 W / 18.50 dBm Report Number: 1506FR277 of 88 A Test Lab Techno Corp. 3 Test Methodology 3.1. Mode of Operation Decision of Test ATL has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as:
Test Mode Mode 1: Normal operation mode Mode 2: IEEE 802.11b link mode Mode 3: IEEE 802.11g link mode Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode Software used to control the EUT for staying in continuous transmitting mode was programmed. After verification, all tests were carried out with the worst case test modes as shown below except radiated spurious emission below 1GHz and power line conducted emissions below 30MHz, which worst case was in normal link mode only. Test Mode ANT-0 ANT-1 ANT-0+1 Mode 2: IEEE 802.11b link mode Mode 3: IEEE 802.11g link mode Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode V V V V V V V V V V V V Test Mode Antenna Delivery Test Channel Data Rate Mode 2: IEEE 802.11b link mode Mode 3: IEEE 802.11g link mode Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode 2TX / 2RX 2TX / 2RX 2TX / 2RX 2TX / 2RX 1, 6, 11 1, 6, 11 1, 6, 11 3, 6, 9 1 6 13 27 Duty cycle Test Mode Frequency
(MHz) on time
(ms) Mode 2: IEEE 802.11b link mode Mode 3: IEEE 802.11g link mode Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode 2412.0 2412.0 2412.0 2422.0 12.180 2.055 0.980 0.500 on+off time
(ms) 12.230 2.090 1.010 0.525 Duty cycle
(%) 0.996 0.983 0.970 0.952 Duty Factor
(dB) 0.018 0.073 0.131 0.212 1/T Minimum VBW
(kHz) 0.010 0.010 1.020 2.000 Report Number: 1506FR278 of 88 A Test Lab Techno Corp. Duty Cycle Graphs Mode 2: IEEE 802.11b link mode On time On+off time Report Number: 1506FR279 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g Mode On time On+off time Report Number: 1506FR2710 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz Mode On time On+off time Report Number: 1506FR2711 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz Mode On time On+off time 3.2. EUT Exercise Software 1. Setup the EUT shown on 3.3. 2. Turn on the power of all equipment. 3. Turn Wi-Fi function link to Notebook 4. EUT run test program. Report Number: 1506FR2712 of 88 A Test Lab Techno Corp. 3.3. Configuration of Test System Details Notebook PoE Adapter EUT EUT PoE Adapter Notebook AC Input AC Input Remote Site Conducted Emissions Radiated Emissions Report Number: 1506FR2713 of 88 A Test Lab Techno Corp. 3.4. Test Site Environment Items Required (IEC 60068-1) Temperature (C) Humidity (%RH) Barometric pressure (mbar) 15-35 25-75 860-1060 Actual 26 60 950 Report Number: 1506FR2714 of 88 A Test Lab Techno Corp. 4 Conducted Emission Measurement 4.1. Limit Frequency (MHz) 0.15 - 0.5 0.50 - 5.0 5.0 - 30.0 4.2. Test Instruments Quasi-peak 66 to 56 56 60 Average 56 to 46 46 50 Describe Manufacturer Model Number Serial Number Cal. Date Remark Test Receiver LISN LISN RF Cable Test Site R&S R&S R&S EMCI ATL ESCI ENV216 ENV216 RG 214/U TE02 100367 101040 101041 TE-02 TE02 06/12/2014 03/10/2015 03/06/2015 06/30/2014
(1)
(1)
(1)
(1) N.C.R.
-----
Remark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request. 4.3. Test Setup Report Number: 1506FR2715 of 88 A Test Lab Techno Corp. 4.4. Test Procedure The power line conducted emission measurements were performed in a shielded enclosure. The EUT was assembled on a wooden table which is 80 centimeters high, was placed 40 centimeters from the back wall and at least 1 meter from the sidewall. Power was fed to the EUT from the public utility power grid through a line filter and EMCO Model 3162/2 SH Line Impedance Stabilization Networks (LISN). The LISN housing, measuring instrumentation case, ground plane, etc., were electrically bonded together at the same RF potential. The Spectrum analyzer was connected to the AC line through an isolation transformer. The 50-ohm output of the LISN was connected to the spectrum analyzer directly. Conducted emission levels were in the CISPR quasi-peak detection mode. The analyzer's 6 dB bandwidth was set to 9 KHz. No post-detector video filter was used. The spectrum was scanned from 150 KHz to 30 MHz. The physical arrangement of the test system and associated cabling was varied (within the scope of arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in amplitude and frequency. All spurious emission frequencies were observed. The highest emission amplitudes relative to the appropriate limit were measured and have been recorded in paragraph 4.1. Report Number: 1506FR2716 of 88 A Test Lab Techno Corp. 4.5. Test Result Standard:
Test item:
FCC Part 15C Conducted Emission Model Number:
UAP-AC-LITE Mode:
Description:
Mode 1 Line:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
L1 AC 120V/60Hz 26()/60%RH 06/08/2015 Eric Ou Yang No. Frequency
(MHz) 0.1660 0.1940 0.5260 1.9140 2.6140 3.7740 1 2 3 4 5 6 QP reading
(dBuV) 41.00 36.74 31.42 21.41 20.09 19.66 AVG reading
(dBuV) 26.00 19.81 22.96 14.43 11.21 9.08 Correction factor
(dB) 9.64 9.64 9.65 9.76 9.78 9.83 QP result
(dBuV) 50.64 AVG result
(dBuV) 35.64 QP limit
(dBuV) 65.16 AVG limit
(dBuV) 55.16 QP margin
(dB)
-14.52 AVG margin
(dB)
-19.52 46.38 29.45 63.86 53.86
-17.48
-24.41 41.07 32.61 56.00 46.00
-14.93
-13.39 31.17 24.19 56.00 46.00
-24.83
-21.81 29.87 20.99 56.00 46.00
-26.13
-25.01 29.49 18.91 56.00 46.00
-26.51
-27.09 Note: 1. Result (dBuV) = Correction factor (dB) + Reading(dBuV). 2. Correction factor (dB) = Cable loss (dB) + L.I.S.N. factor (dB). Remark Pass Pass Pass Pass Pass Pass Report Number: 1506FR2717 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Conducted Emission Model Number:
UAP-AC-LITE Mode:
Description:
Mode 1 Line:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
N AC 120V/60Hz 26()/60%RH 06/08/2015 Eric Ou Yang No. Frequency
(MHz) 0.1660 0.2100 0.5020 0.6300 0.8860 2.3620 1 2 3 4 5 6 QP reading
(dBuV) 41.05 30.89 30.08 20.51 19.53 22.26 AVG reading
(dBuV) 27.20 11.00 21.71 5.77 9.06 12.16 Correction factor
(dB) 9.62 9.62 9.64 9.64 9.66 9.72 QP result
(dBuV) 50.67 AVG result
(dBuV) 36.82 QP limit
(dBuV) 65.16 AVG limit
(dBuV) 55.16 QP margin
(dB)
-14.49 AVG margin
(dB)
-18.34 40.51 20.62 63.21 53.21
-22.70
-32.59 39.72 31.35 56.00 46.00
-16.28
-14.65 30.15 15.41 56.00 46.00
-25.85
-30.59 29.19 18.72 56.00 46.00
-26.81
-27.28 31.98 21.88 56.00 46.00
-24.02
-24.12 Note: 1. Result (dBuV) = Correction factor (dB) + Reading(dBuV). 2. Correction factor (dB) = Cable loss (dB) + L.I.S.N. factor (dB). Remark Pass Pass Pass Pass Pass Pass Report Number: 1506FR2718 of 88 A Test Lab Techno Corp. 5 Radiated Emission Measurement 5.1. Limit According to 15.209(a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table:
Field Strength
(V/m at meter) 2400 / F (kHz) Measurement Distance 0.009 0.490 Frequency
(meters)
(MHz) 300 0.490 1.705 1.705 30.0 30 - 88 88-216 216-960 Above 960 24000 / F (kHz) 30 100**
150**
200**
500 30 30 3 3 3 3
** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241. 5.2. Test Instruments Equipment Manufacturer Model Number Serial Number Cal. Date Remark 3 Meter Chamber RF Pre-selector Spectrum Analyzer Pre Amplifier Pre Amplifier Broadband Antenna
(30MHz~1GHz) Horn Antenna
(1~18GHz) Horn Antenna
(18~40GHz) Loop Antenna Microwave Cable Microwave Cable Test Site Agilent Agilent Agilent Agilent SCHWARZBECK MESS-ELEKTRONIK SCHWARZBECK MESS-ELEKTRONIK SCHWARZBECK MESS-ELEKTRONIK COM-POWER CORPORATION EMCI EMCI ATL N9039A E4446A 8449B 8447D MY46520256 01/06/2015 MY46180578 01/06/2015 3008A02237 02/24/2015 2944A10961 02/24/2015 VULB9163 9163-270 07/22/2014 BBHA9120D 9120D-550 06/12/2015 BBHA9170 9170-320 07/02/2014 AL-130 121014 02/02/2015 EMC-104-SM-S M-14000 EMC104-SM-S M-600 TE01 140202 02/24/2015 140301 888001 02/24/2015 08/28/2014 Remark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request.
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1) Report Number: 1506FR2719 of 88 A Test Lab Techno Corp. 5.3. Setup 9kHz ~ 30MHz 3m EUT Turntable 0.8m 1m Reference ground plane Below 1GHz Loop antenna Spectrum /
Receiver Report Number: 1506FR2720 of 88 A Test Lab Techno Corp. Above 1GHz Report Number: 1506FR2721 of 88 A Test Lab Techno Corp. 5.4. Test Procedure Final radiation measurements were made on a three-meter, Semi Anechoic Chamber. The EUT system was placed on a nonconductive turntable which is 1.5 meters height, top surface 1.0 x 1.5 meter. The spectrum was examined from 250 MHz to 2.5 GHz in order to cover the whole spectrum below 10th harmonic which could generate from the EUT. During the test, EUT was set to transmit continuously & Measurements spectrum range from 9 kHz to 26.5 GHz is investigated. For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection measurements or 120 kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1 GHz the resolution bandwidth is set to 1 MHz, and then the video bandwidth is set to 1 MHz for peak measurements and 10 Hz for average measurements when Duty cycle >98% / 1/T for average measurements when Duty cycle <98%. A nonconductive material surrounded the EUT to supporting the EUT for standing on tree orthogonal planes. At each condition, the EUT was rotated 360 degrees, and the antenna was raised and lowered from one to four meters to find the maximum emission levels. Measurements were taken using both horizontal and vertical antenna polarization. SCHWARZBECK MESS-ELEKTRONIK Biconilog Antenna (mode VULB9163) at 3 Meter and the SCHWARZBECK Double Ridged Guide Antenna (model BBHA9120D&9170) was used in frequencies 1 26.5 GHz at a distance of 1 meter. All test results were extrapolated to equivalent signal at 3 meters utilizing an inverse linear distance extrapolation Factor (20dB/decade). For testing above 1GHz, the emission level of the EUT in peak mode was 20dB lower than average limit (that means the emission level in peak mode also complies with the limit in average mode), then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in average mode again and reported. Appropriate preamplifiers were used for improving sensitivity and precautions were taken to avoid overloading or desensitizing the spectrum analyzer. No post detector video filters were used in the test. The spectrum analyzers 6 dB bandwidth was set to 1 MHz, and the analyzer was operated in the peak detection mode, for frequencies both below and up 1 GHz. The average levels were obtained by subtracting the duty cycle correction factor from the peak readings. The following procedures were used to convert the emission levels measured in decibels referenced to 1 microvolt
(dBuV) into field intensity in micro volts pre meter (uV/m). The actual field intensity in decibels referenced to 1 microvolt in to field intensity in micro colts per meter (dBuV/m). Report Number: 1506FR2722 of 88 A Test Lab Techno Corp. The actual field is intensity in referenced to 1 microvolt per meter (dBuV/m) is determined by algebraically adding the measured reading in dBuV, the antenna factor (dB), and cable loss (dB) and Subtracting the gain of preamplifier
(dB) is auto calculate in spectrum analyzer.
(1) Amplitude (dBuV/m) = FI (dBuV) +AF (dBuV) +CL (dBuV)-Gain (dB) FI= Reading of the field intensity. AF= Antenna factor. CL= Cable loss. P.S Amplitude is auto calculate in spectrum analyzer.
(2) Actual Amplitude (dBuV/m) = Amplitude (dBuV)-Dis(dB) The FCC specified emission limits were calculated according the EUT operating frequency and by following linear interpolation equations:
(a) For fundamental frequency : Transmitter Output < +30dBm
(b) For spurious frequency : Spurious emission limits = fundamental emission limit /10 Data of measurement within this frequency range without mark in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. Report Number: 1506FR2723 of 88 A Test Lab Techno Corp. 5.5. Test Result Below 1GHz Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Mode:
Frequency
(MHz) 173.5000 350.0000 462.5000 605.0000 750.0000 872.0000 121.0000 286.5000 355.0000 465.0000 667.0000 826.0000 Mode 1 Reading
(dBuV) 39.22 Correct Factor
(dB/m)
-11.87 41.41 29.91 25.56 27.76 27.42 40.88 30.83 30.29 27.77 29.15 25.68
-8.48
-6.07
-3.09
-0.26 1.92
-14.11
-9.79
-8.37
-6.04
-2.17 0.89 Date:
Test By:
Limit
(dBuV/m) Result
(dBuV/m) 27.35 32.93 23.84 22.47 27.50 29.34 26.77 21.04 21.92 21.73 26.98 26.57 43.50 46.00 46.00 46.00 46.00 46.00 43.50 46.00 46.00 46.00 46.00 46.00 Margin
(dB)
-16.15
-13.07
-22.16
-23.53
-18.50
-16.66
-16.73
-24.96
-24.08
-24.27
-19.02
-19.43 06/02/2015 Eric Ou Yang Remark Ant.Polar. QP QP QP QP QP QP QP QP QP QP QP QP H / V H H H H H H V V V V V V Note: No emission found between lowest internal used/generated frequency to 30MHz (9kHz~30MHz). Report Number: 1506FR2724 of 88 A Test Lab Techno Corp. Above 1GHz Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3198.000 4605.000 6670.000 3177.000 4605.000 6705.000 Mode 2 2412MHz Reading
(dBuV) 37.46 Correct Factor
(dB/m) 6.75 33.69 35.10 37.70 34.01 34.24 9.92 12.76 6.68 9.92 12.78 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-29.79
-30.39
-26.14
-29.62
-30.07
-26.98 3m AC 120V/60Hz 26()/60%RH 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Result
(dBuV/m) 44.21 43.61 47.86 44.38 43.93 47.02 Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3177.000 4577.000 6677.000 3177.000 4598.000 6691.000 Mode 2 2437MHz Reading
(dBuV) 38.37 Correct Factor
(dB/m) 6.68 33.38 33.72 37.62 33.84 34.83 9.87 12.75 6.68 9.91 12.78 Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-28.95
-30.75
-27.53
-29.70
-30.25
-26.39 Result
(dBuV/m) 45.05 43.25 46.47 44.30 43.75 47.61 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2725 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3163.000 4591.000 6691.000 3205.000 4605.000 6691.000 Mode 2 2462MHz Reading
(dBuV) 37.19 Correct Factor
(dB/m) 6.64 34.14 34.26 38.07 33.74 33.95 9.90 12.78 6.77 9.92 12.78 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-30.17
-29.96
-26.96
-29.16
-30.34
-27.27 3m AC 120V/60Hz 26()/60%RH 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Result
(dBuV/m) 43.83 44.04 47.04 44.84 43.66 46.73 Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3205.000 4591.000 6705.000 3191.000 4570.000 6698.000 Mode 3 2412MHz Reading
(dBuV) 36.83 Correct Factor
(dB/m) 6.77 34.68 33.92 37.96 33.57 33.87 9.90 12.78 6.72 9.87 12.77 Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-30.40
-29.42
-27.30
-29.32
-30.56
-27.36 Result
(dBuV/m) 43.60 44.58 46.70 44.68 43.44 46.64 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2726 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3177.000 4577.000 6649.000 3191.000 4591.000 6677.000 Mode 3 2437MHz Reading
(dBuV) 37.55 Correct Factor
(dB/m) 6.68 34.75 33.78 36.93 34.76 33.93 9.87 12.74 6.72 9.90 12.75 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-29.77
-29.38
-27.48
-30.35
-29.34
-27.32 3m AC 120V/60Hz 26()/60%RH 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Result
(dBuV/m) 44.23 44.62 46.52 43.65 44.66 46.68 Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3170.000 4577.000 6691.000 3170.000 4577.000 6677.000 Mode 3 2462MHz Reading
(dBuV) 37.85 Correct Factor
(dB/m) 6.65 35.23 33.04 38.18 34.52 33.35 9.87 12.78 6.65 9.87 12.75 Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-29.50
-28.90
-28.18
-29.17
-29.61
-27.90 Result
(dBuV/m) 44.50 45.10 45.82 44.83 44.39 46.10 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2727 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3163.000 4563.000 6698.000 3170.000 4577.000 6677.000 Mode 4 2412MHz Reading
(dBuV) 37.85 Correct Factor
(dB/m) 6.64 33.01 33.59 37.57 33.39 34.08 9.86 12.77 6.65 9.87 12.75 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-29.51
-31.13
-27.64
-29.78
-30.74
-27.17 3m AC 120V/60Hz 26()/60%RH 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Result
(dBuV/m) 44.49 42.87 46.36 44.22 43.26 46.83 Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3170.000 4549.000 6691.000 3177.000 4570.000 6677.000 Mode 4 2437MHz Reading
(dBuV) 37.30 Correct Factor
(dB/m) 6.65 32.99 33.29 38.30 33.82 33.92 9.83 12.78 6.68 9.87 12.75 Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-30.05
-31.18
-27.93
-29.02
-30.31
-27.33 Result
(dBuV/m) 43.95 42.82 46.07 44.98 43.69 46.67 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2728 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3177.000 4577.000 6698.000 3177.000 4591.000 6705.000 Mode 4 2462MHz Reading
(dBuV) 36.34 Correct Factor
(dB/m) 6.68 33.95 33.44 37.05 33.83 33.10 9.87 12.77 6.68 9.90 12.78 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-30.98
-30.18
-27.79
-30.27
-30.27
-28.12 3m AC 120V/60Hz 26()/60%RH 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Result
(dBuV/m) 43.02 43.82 46.21 43.73 43.73 45.88 Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3149.000 4542.000 6663.000 3163.000 4570.000 6663.000 Mode 5 2422MHz Reading
(dBuV) 37.59 Correct Factor
(dB/m) 6.60 33.74 34.14 36.60 33.86 34.08 9.83 12.75 6.64 9.87 12.75 Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-29.81
-30.43
-27.11
-30.76
-30.27
-27.17 Result
(dBuV/m) 44.19 43.57 46.89 43.24 43.73 46.83 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2729 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3170.000 4577.000 6677.000 3198.000 4626.000 6670.000 Mode 5 2437MHz Reading
(dBuV) 36.75 Correct Factor
(dB/m) 6.65 34.11 33.76 38.35 33.97 33.82 9.87 12.75 6.75 9.95 12.76 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-30.60
-30.02
-27.49
-28.90
-30.08
-27.42 3m AC 120V/60Hz 26()/60%RH 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Result
(dBuV/m) 43.40 43.98 46.51 45.10 43.92 46.58 Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency:
Frequency
(MHz) 3170.000 4570.000 6663.000 3170.000 4605.000 6663.000 Mode 5 2452MHz Reading
(dBuV) 36.61 Correct Factor
(dB/m) 6.65 33.65 33.89 37.82 33.28 34.01 9.87 12.75 6.65 9.92 12.75 Test Distance:
3m Power:
Temp.()/Hum.(%RH):
AC 120V/60Hz 26()/60%RH Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-30.74
-30.48
-27.36
-29.53
-30.80
-27.24 Result
(dBuV/m) 43.26 43.52 46.64 44.47 43.20 46.76 06/19/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2730 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Mode:
Frequency
(MHz) 2841.000 4563.000 7671.000 2841.000 4542.000 7657.000 2.4GHz+5GHz Simultaneous Transmitting Reading
(dBuV) 35.65 Correct Factor
(dB/m) 5.70 31.83 32.01 34.60 31.22 31.35 9.86 13.30 5.70 9.83 13.28 Result
(dBuV/m) 41.35 41.69 45.31 40.30 41.05 44.63 Test Distance:
Power:
Temp.()/Hum.(%RH):
Date:
Test By:
Limit
(dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Margin
(dB)
-32.65
-32.31
-28.69
-33.70
-32.95
-29.37 3m AC 120V/60Hz 26()/60%RH 06/26/2015 Eric Ou Yang Remark Ant.Polar. peak peak peak peak peak peak H / V H H H V V V Report Number: 1506FR2731 of 88 A Test Lab Techno Corp. 6 Maximum Conducted Output Power Measurement 6.1. Limit For systems using digital modulation in the 2400-2483.5MHz, the limit for maximum output power is 30dBm. 6.2. Test Setup EUT Power Sensor Power Meter 6.3. Test Instruments Equipment Manufacturer Model Number Serial Number Cal. Date Remark Power Sensor Power Meter Test Site Anritsu Anritsu ATL MA2411B ML2495A TE05 1126022 1135009 TE05 08/21/2014 08/21/2014 N.C.R.
(1)
(1)
-----
Remark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request. 6.4. Test Procedure The tests below are run with the EUTs transmitter set at high power in TX mode. The EUT is needed to force selection of output power level and channel number. While testing, EUT was set to transmit continuously. Remove the Subjective devices antenna and connect the RF output port to power sensor. The maximum output power shall not exceed 1 watt. Use a direct connection between the antenna port of transmitter and the power sensor, for prevent the power sensor input attenuation 40-50 dB. Set the RBW Bandwidth of the emission or use a channel power meter mode. For antennas with gains of 6 dBi or less, maximum allowed transmitter output is 1 watt (+30 dBm). For antennas with gains greater than 6 dBi, transmitter output level must be decreased by an amount equal to (GAIN - 6)/3 dBm. The antenna port of the EUT was connected to the input of a power sensor. Power was read directly and cable loss correction was added to the reading to obtain power at the EUT antenna terminals. Report Number: 1506FR2732 of 88 A Test Lab Techno Corp. 6.5. Test Result Model Number UAP-AC-LITE Test Item Test Mode Date of Test Maximum Conducted Output Power Mode 2: IEEE 802.11b link mode 06/02/2015 Test Site TE05 Frequency
(MHz) 2412 2437 2462 2437 2437 2437 Data Rate 1M
(dBm) 14.32 14.08 14.40 2M 13.97 5.5M 13.98 11M 14.06 Frequency
(MHz) Data Rate 2412 2437 2462 2437 2437 2437 1M 2M 5.5M 11M Average Power Peak Power ANT-0 ANT-1 ANT-0 ANT-1
(W)
(dBm) 0.027 14.81 0.026 14.65 0.028 13.96 0.025 14.17 0.025 14.05 0.025 14.03 Average Power ANT-0+1
(W) 0.030 0.029 0.025 0.026 0.025 0.025
(dBm) 17.15 16.94 17.21 16.83 16.85 16.90
(W) 0.052 0.049 0.053 0.048 0.048 0.049
(dBm) 17.68 17.52 16.75 17.10 16.98 16.94
(W) 0.059 0.056 0.047 0.051 0.050 0.049 Peak Power ANT-0+1
(dBm) 17.58 17.38 17.20 17.08 17.03 17.06
(W) 0.057 0.055 0.052 0.051 0.050 0.051
(dBm) 20.43 20.25 20.00 19.98 19.93 19.93
(W) 0.110 0.106 0.100 0.099 0.098 0.098 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30 Report Number: 1506FR2733 of 88 A Test Lab Techno Corp. Model Number UAP-AC-LITE Test Item Test Mode Date of Test Maximum Conducted Output Power Mode 3: IEEE 802.11g link mode 06/02/2015 Test Site TE05 Frequency
(MHz) Data Rate 2412 2437 2462 2437 2437 2437 2437 2437 2437 2437 6M 9M 12M 18M 24M 36M 48M 54M Frequency
(MHz) Data Rate 2412 2437 2462 2437 2437 2437 2437 2437 2437 2437 6M 9M 12M 18M 24M 36M 48M 54M Average Power Peak Power ANT-0 ANT-1 ANT-0 ANT-1
(dBm)
(W) 12.52 0.018 13.11 0.020 13.16 0.021 12.99 0.020 13.06 0.020 13.08 0.020 12.85 0.019 12.82 0.019 12.93 0.020 13.10 0.020
(dBm) 12.57 13.18 13.15 13.17 13.15 13.13 12.92 13.05 12.89 13.16 Average Power ANT-0+1
(W) 0.018 0.021 0.021 0.021 0.021 0.021 0.020 0.020 0.019 0.021
(dBm) 15.55 16.10 16.13 16.00 16.04 16.05 15.87 15.81 15.95 16.08
(W) 0.036 0.041 0.041 0.040 0.040 0.040 0.039 0.038 0.039 0.041
(dBm)
(W) 15.31 0.034 15.95 0.039 15.91 0.039 15.94 0.039 15.91 0.039 15.88 0.039 15.68 0.037 15.77 0.038 15.64 0.037 15.92 0.039 Peak Power ANT-0+1
(dBm) 15.56 16.16 16.17 16.09 16.12 16.12 15.90 15.95 15.92 16.14
(W) 0.036 0.041 0.041 0.041 0.041 0.041 0.039 0.039 0.039 0.041
(dBm) 18.44 19.04 19.03 18.98 18.99 18.98 18.79 18.80 18.81 19.01
(W) 0.070 0.080 0.080 0.079 0.079 0.079 0.076 0.076 0.076 0.080 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30 Report Number: 1506FR2734 of 88 A Test Lab Techno Corp. Model Number UAP-AC-LITE Test Item Test Mode Date of Test Maximum Conducted Output Power Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode 06/02/2015 Test Site TE05 Average Power Peak Power ANT-0 ANT-1 ANT-0 ANT-1 Frequency
(MHz) 2412 2437 2462 2437 2437 2437 2437 2437 2437 2437 Data Rate 13M
(dBm)
(W) 12.67 0.018 12.99 0.020 12.70 0.019 12.91 0.020 26M 12.86 0.019 39M 12.69 0.019 52M 78M 12.13 0.016 104M 12.17 0.016 117M 12.20 0.017 130M 12.24 0.017
(dBm) 12.95 13.47 13.42 13.43 13.46 13.22 12.98 12.84 12.87 12.75 Average Power
(W) 0.020 0.022 0.022 0.022 0.022 0.021 0.020 0.019 0.019 0.019
(dBm) 15.68 15.99 15.73 15.92 15.88 15.72 15.17 15.21 15.27 15.32
(W) 0.037 0.040 0.037 0.039 0.039 0.037 0.033 0.033 0.034 0.034
(dBm)
(W) 15.70 0.037 16.25 0.042 16.17 0.041 16.19 0.042 16.24 0.042 16.00 0.040 15.72 0.037 15.56 0.036 15.61 0.036 15.51 0.036 Peak Power ANT-0+1 Frequency
(MHz) Data Rate 2412 2437 2462 2437 2437 2437 2437 2437 2437 2437 13M 26M 39M 52M 78M 104M 117M 130M ANT-0+1
(dBm) 15.82 16.25 16.09 16.19 16.18 15.97 15.59 15.53 15.56 15.51
(W) 0.038 0.042 0.041 0.042 0.042 0.040 0.036 0.036 0.036 0.036
(dBm) 18.70 19.13 18.97 19.07 19.07 18.87 18.46 18.40 18.45 18.43
(W) 0.074 0.082 0.079 0.081 0.081 0.077 0.070 0.069 0.070 0.070 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30 Report Number: 1506FR2735 of 88 A Test Lab Techno Corp. Model Number UAP-AC-LITE Test Item Test Mode Date of Test Maximum Conducted Output Power Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode 06/02/2015 Test Site TE05 Average Power Peak Power ANT-0 ANT-1 ANT-0 ANT-1 Frequency
(MHz) 2422 2437 2452 2437 2437 2437 2437 2437 2437 2437 Data Rate 27M
(dBm)
(W) 12.11 0.016 12.37 0.017 12.06 0.016 12.14 0.016 54M 81M 12.21 0.017 108M 11.10 0.013 162M 11.45 0.014 216M 11.16 0.013 243M 11.01 0.013 270M 10.80 0.012
(dBm) 12.31 12.83 12.58 12.73 12.74 12.71 12.06 11.81 11.77 11.49 Average Power
(W) 0.017 0.019 0.018 0.019 0.019 0.019 0.016 0.015 0.015 0.014
(dBm) 15.14 15.42 15.07 15.19 15.28 14.23 14.56 14.31 14.11 13.86
(W) 0.033 0.035 0.032 0.033 0.034 0.026 0.029 0.027 0.026 0.024
(dBm)
(W) 15.12 0.033 15.55 0.036 15.35 0.034 15.48 0.035 15.49 0.035 15.45 0.035 14.91 0.031 14.78 0.030 14.71 0.030 14.44 0.028 Peak Power ANT-0+1 Frequency
(MHz) Data Rate 2422 2437 2452 2437 2437 2437 2437 2437 2437 2437 27M 54M 81M 108M 162M 216M 243M 270M ANT-0+1
(dBm) 15.22 15.62 15.34 15.46 15.49 14.99 14.78 14.51 14.42 14.17
(W) 0.033 0.036 0.034 0.035 0.035 0.032 0.030 0.028 0.028 0.026
(dBm) 18.14 18.50 18.22 18.35 18.40 17.89 17.75 17.56 17.43 17.17
(W) 0.065 0.071 0.066 0.068 0.069 0.062 0.060 0.057 0.055 0.052 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30 Limit
(dBm)
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30
< 30 Report Number: 1506FR2736 of 88 A Test Lab Techno Corp. 7 6dB RF Bandwidth Measurement 7.1. Limit 6dB RF Bandwidth: Systems using digital modulation techniques may operate in the 24002483.5 MHz bands. The minimum 6 dB band-width shall be at least 500 kHz. 7.2. Test Setup Spectrum Analyzer RF Cable EUT 7.3. Test Instruments Equipment Manufacturer Model Number Serial Number Cal. Date Remark Spectrum Analyzer Test Site Agilent ATL E4445A MY45300744 12/16/2014 TE05 TE05 N.C.R.
(1)
-----
dRemark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request. 7.4. Test Procedure The EUT tested to DTS test procedure of KDB558074D01 for compliance to FCC 47CFR 15.247 requirements. 6dB RF Bandwidth: The antenna port of the EUT was connected to the input of a spectrum analyzer. Analyzer RES RBW was set to 100 kHz. For each RF output channel investigated, the spectrum analyzer center frequency was set to the channel carrier. A peak output reading was taken, a DISPLAY line was drawn 6 dB lower than peak level. The 6 dB bandwidth was determined from where the channel output spectrum intersected the display line. The test was performed at 3 channels (Channel low, middle, high) 99 % Occupied Bandwidth: The transmitter shall be operated at its maximum carrier power measured under normal test conditions. The video bandwidth shall be set to 3 times the resolution bandwidth. Video averaging is not permitted. Where practical, a sampling detector shall be used since a peak or, peak hold, may produce a wider bandwidth than actual. The trace data points are recovered and are directly summed in linear terms. The recovered amplitude data points, beginning at the lowest frequency, are placed in a running sum until 0.5% of the total is reached and that frequency recorded. The process is repeated for the highest frequency data points. This frequency is recorded. Report Number: 1506FR2737 of 88 A Test Lab Techno Corp. 7.5. Test Result Model Number Test Item Test Mode Date of Test Test Mode Mode 2 Mode 3 Mode 4 Mode 5 UAP-AC-LITE 6dB RF Bandwidth Mode 2: IEEE 802.11b link mode Mode 3: IEEE 802.11g link mode Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode 06/15/2015 Frequency Measurement
(MHz) 2412 2437 2462 2412 2437 2462 2412 2437 2462 2422 2437 2452
(kHz) 7115 6580 6620 15073 15139 15125 15127 15137 15094 35012 31312 32548 Test Site TE05 Limit
(kHz)
> 500
> 500
> 500
> 500
> 500
> 500
> 500
> 500
> 500
> 500
> 500
> 500 Report Number: 1506FR2738 of 88 A Test Lab Techno Corp. 7.6. Test Graphs Mode 2: IEEE 802.11b link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2739 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2740 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2741 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-0 2422 2437 2452 Report Number: 1506FR2742 of 88 A Test Lab Techno Corp. Mode 2: IEEE 802.11b link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2743 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2744 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2745 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-1 2422 2437 2452 Report Number: 1506FR2746 of 88 A Test Lab Techno Corp. 8 Maximum Power Density Measurement 8.1. Limit For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. 8.2. Test Setup Spectrum Analyzer EUT RF Cable 8.3. Test Instruments Equipment Manufacturer Model Number Serial Number Cal. Date Remark Spectrum Analyzer Test Site Agilent ATL E4445A MY45300744 12/16/2014 TE05 TE05 N.C.R.
(1)
-----
Remark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request. 8.4. Test Procedure The EUT tested to DTS test procedure of KDB558074D01 for compliance to FCC 47CFR 15.247 requirements. 1. Set analyzer center frequency to DTS channel center frequency. 2. Set the span to 1.5 times the DTS bandwidth. 3. Set the RBW to: 3 kHz RBW 100 kHz. 4. Set the VBW 3 RBW. 5. Detector = peak. 6. Sweep time = auto couple. 7. Trace mode = max hold. 8. Allow trace to fully stabilize. 9. Use the peak marker function to determine the maximum amplitude level within the RBW. 10. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. Report Number: 1506FR2747 of 88 A Test Lab Techno Corp. 8.5. Test Result Model Number Test Item Test Mode Date of Test UAP-AC-LITE Maximum Power Density Mode 2: IEEE 802.11b link mode Mode 3: IEEE 802.11g link mode Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode 06/15/2015 Measurement
(dBm/3KHz) Test Mode Frequency
(MHz) Mode 2 Mode 3 Mode 4 Mode 5 2412 2437 2462 2412 2437 2462 2412 2437 2462 2422 2437 2452 ANT-0
-7.957
-7.259
-7.766
-11.240
-10.060
-10.280
-11.530
-11.060
-11.330
-15.050
-15.450
-14.610 Test Site TE05 ANT-1
-7.008
-7.797
-7.057
-10.710
-10.620
-11.460
-11.350
-11.280
-11.540
-14.180
-13.100
-13.270 Limit
(dBm/3KHz)
< 8
< 8
< 8
< 8
< 8
< 8
< 8
< 8
< 8
< 8
< 8
< 8 Report Number: 1506FR2748 of 88 A Test Lab Techno Corp. 8.6. Test Graphs Mode 2: IEEE 802.11b link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2749 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2750 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2751 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-0 2422 2437 2452 Report Number: 1506FR2752 of 88 A Test Lab Techno Corp. Mode 2: IEEE 802.11b link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2753 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2754 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2755 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-1 2422 2437 2452 Report Number: 1506FR2756 of 88 A Test Lab Techno Corp. 9 Out of Band Conducted Emissions Measurement 9.1. Limit In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power 9.2. Test Setup Spectrum Analyzer EUT RF Cable 9.3. Test Instruments Equipment Manufacturer Model Number Serial Number Cal. Date Remark Spectrum Analyzer Spectrum Analyzer Test Site Agilent Agilent ATL E4445A E4408B TE05 MY45300744 12/16/2014 MY45107753 07/24/2014 TE05 N.C.R.
(2)
(1)
-----
Remark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request. 9.4. Test Procedure In any 100 kHz bandwidth outside the EUT pass band, the RF power produced by the modulation products of the spreading sequence, the information sequence, and the carrier frequency shall be at least 20 dB below that of the maximum in-band 100 kHz emission, antenna output of the EUT was coupled directly to spectrum analyzer; if an external attenuator and/or cable was used, these losses are compensated for with the analyzer OFFSET function. All other types of emissions from the EUT shall meet the general limits for radiated frequencies outside the pass band. The test was performed at 3 channels. Report Number: 1506FR2757 of 88 A Test Lab Techno Corp. 9.5. Test Graphs Reference level Mode 2: IEEE 802.11b link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2758 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2759 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2760 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-0 2422 2437 2452 Report Number: 1506FR2761 of 88 A Test Lab Techno Corp. Mode 2: IEEE 802.11b link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2762 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2763 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2764 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-1 2422 2437 2452 Report Number: 1506FR2765 of 88 A Test Lab Techno Corp. Out of Band Conducted Emissions Mode 2: IEEE 802.11b link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2766 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2767 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-0 2412 2437 2462 Report Number: 1506FR2768 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-0 2422 2437 2452 Report Number: 1506FR2769 of 88 A Test Lab Techno Corp. Mode 2: IEEE 802.11b link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2770 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2771 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-1 2412 2437 2462 Report Number: 1506FR2772 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-1 2422 2437 2452 Report Number: 1506FR2773 of 88 A Test Lab Techno Corp. Conducted Band Edge Mode 2: IEEE 802.11b link mode_ANT-0 2412 2462 Report Number: 1506FR2774 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-0 2412 2462 Report Number: 1506FR2775 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-0 2412 2462 Report Number: 1506FR2776 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-0 2422 2452 Report Number: 1506FR2777 of 88 A Test Lab Techno Corp. Mode 2: IEEE 802.11b link mode_ANT-1 2412 2462 Report Number: 1506FR2778 of 88 A Test Lab Techno Corp. Mode 3: IEEE 802.11g link mode_ANT-1 2412 2462 Report Number: 1506FR2779 of 88 A Test Lab Techno Corp. Mode 4: IEEE 802.11n 2.4GHz 20MHz link mode_ANT-1 2412 2462 Report Number: 1506FR2780 of 88 A Test Lab Techno Corp. Mode 5: IEEE 802.11n 2.4GHz 40MHz link mode_ANT-1 2422 2452 Report Number: 1506FR2781 of 88 A Test Lab Techno Corp. 10 Band Edges Measurement 10.1. Limit In any 100 kHz bandwidth outside the intentional radiation frequency band, the radio frequency power shall be at least 20 dB below the highest level of the radiated power. In addition, radiated emissions which fall in the restricted bands must also comply with the radiated emission limits. 10.2. Test Setup EUT 3m Spectrum Analyzer 4m RF Cable Preamplifier 10.3. Test Instruments Equipment Manufacturer Model Number Serial Number Cal. Date Remark 3 Meter Chamber RF Pre-selector Spectrum Analyzer Pre Amplifier Pre Amplifier Horn Antenna
(1~18GHz) Microwave Cable Microwave Cable Test Site Agilent Agilent Agilent Agilent SCHWARZBECK MESS-ELEKTRONIK EMCI EMCI ATL N9039A E4446A 8449B 8447D MY46520256 01/06/2015 MY46180578 01/06/2015 3008A02237 02/24/2015 2944A10961 02/24/2015 BBHA9120D 9120D-550 06/12/2015 EMC-104-SM-S M-14000 EMC104-SM-S M-600 TE01 140202 02/24/2015 140301 888001 02/24/2015 08/28/2014 Remark: (1) Calibration period 1 year. (2) Calibration period 2 years. (3) Calibration period 3 years. Note: N.C.R. = No Calibration Request.
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1) Report Number: 1506FR2782 of 88 A Test Lab Techno Corp. 10.4. Test Procedure The EUT tested to DTS test procedure of KDB558074D01 for compliance to FCC 47CFR 15.247 requirements. The emissions on the harmonics frequencies, the limits, and the margin of compliance are presented. These tests were made when the transmitter was in full radiated power. The additional test was performed to show compliance with the requirement at the band-edge frequency 2483.5 MHz and up to 2500 MHz and at 2390.0 MHz. The transmitter was configured with the worst case antenna and setup to transmit at the highest channel. Then the field strength was measured at 2483.5 MHz. The transmitter was then configured with the worst case antenna and setup to transmit at the lowest channel. Then the field strength was measured at 2390.0 MHz. These tests were performed at 4 different bit rates. For measurements the resolution bandwidth is set to 1 MHz, and then the video bandwidth is set to 1 MHz for peak measurements and 10 Hz for average measurements when Duty cycle >98% / 1/T for average measurements when Duty cycle <98%. Report Number: 1506FR2783 of 88 A Test Lab Techno Corp. 10.5. Test Result Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2372.040 2372.040 2390.000 2390.000 2373.580 2373.580 2390.000 2390.000 Mode 2 2412 MHz Reading
(dBuV) 60.87 Correct Factor
(dB/m)
-1.80 Result
(dBuV/m) 59.07 46.92 54.05 42.95 63.13 51.62 55.59 47.50
-1.80
-1.73
-1.73
-1.79
-1.79
-1.73
-1.73 45.12 52.32 41.22 61.34 49.83 53.86 45.77 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-14.93
-8.88
-21.68
-12.78
-12.66
-4.17
-20.14
-8.23 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2483.500 2483.500 2484.640 2484.640 2483.500 2483.500 2484.360 2484.360 Mode 2 2462 MHz Reading
(dBuV) 53.64 Correct Factor
(dB/m)
-1.39 Result
(dBuV/m) 52.25 45.70 55.59 45.64 56.96 46.06 59.56 45.68
-1.39
-1.39
-1.39
-1.39
-1.39
-1.39
-1.39 44.31 54.20 44.25 55.57 44.67 58.17 44.29 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-21.75
-9.69
-19.80
-9.75
-18.43
-9.33
-15.83
-9.71 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Report Number: 1506FR2784 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2369.730 2369.730 2390.000 2390.000 2369.180 2369.180 2390.000 2390.000 Mode 3 2412 MHz Reading
(dBuV) 63.54 Correct Factor
(dB/m)
-1.80 Result
(dBuV/m) 61.74 49.61 63.61 45.84 65.28 53.37 64.33 50.43
-1.80
-1.73
-1.73
-1.80
-1.80
-1.73
-1.73 47.81 61.88 44.11 63.48 51.57 62.60 48.70 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-12.26
-6.19
-12.12
-9.89
-10.52
-2.43
-11.40
-5.30 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2483.500 2483.500 2485.000 2485.000 2483.500 2483.500 2484.560 2484.560 Mode 3 2462 MHz Reading
(dBuV) 64.78 Correct Factor
(dB/m)
-1.39 Result
(dBuV/m) 63.39 44.76 72.28 44.60 69.57 47.93 73.64 47.41
-1.39
-1.39
-1.39
-1.39
-1.39
-1.39
-1.39 43.37 70.89 43.21 68.18 46.54 72.25 46.02 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-10.61
-10.63
-3.11
-10.79
-5.82
-7.46
-1.75
-7.98 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Report Number: 1506FR2785 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2367.970 2367.970 2390.000 2390.000 2369.840 2369.840 2390.000 2390.000 Mode 4 2412 MHz Reading
(dBuV) 61.62 Correct Factor
(dB/m)
-1.81 Result
(dBuV/m) 59.81 48.74 60.63 45.28 64.09 52.00 67.45 48.90
-1.81
-1.73
-1.73
-1.80
-1.80
-1.73
-1.73 46.93 58.90 43.55 62.29 50.20 65.72 47.17 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-14.19
-7.07
-15.10
-10.45
-11.71
-3.80
-8.28
-6.83 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2369.840 2369.840 2390.000 2390.000 2369.840 2369.840 2390.000 2390.000 Mode 4 2462 MHz Reading
(dBuV) 64.09 Correct Factor
(dB/m)
-1.80 Result
(dBuV/m) 62.29 52.00 67.45 48.90 64.09 52.00 67.45 48.90
-1.80
-1.73
-1.73
-1.80
-1.80
-1.73
-1.73 50.20 65.72 47.17 62.29 50.20 65.72 47.17 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-11.71
-3.80
-8.28
-6.83
-11.71
-3.80
-8.28
-6.83 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Report Number: 1506FR2786 of 88 A Test Lab Techno Corp. Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2388.240 2388.240 2390.000 2390.000 2388.360 2388.360 2390.000 2390.000 Mode 5 2422 MHz Reading
(dBuV) 66.44 Correct Factor
(dB/m)
-1.74 Result
(dBuV/m) 64.70 45.06 66.59 45.67 69.22 49.39 67.37 49.52
-1.74
-1.73
-1.73
-1.74
-1.74
-1.73
-1.73 43.32 64.86 43.94 67.48 47.65 65.64 47.79 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-9.30
-10.68
-9.14
-10.06
-6.52
-6.35
-8.36
-6.21 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Standard:
Test item:
FCC Part 15C Radiated Emission Model Number:
UAP-AC-LITE Test Distance:
Power:
Temp.()/Hum.(%RH):
Mode:
Frequency:
Frequency
(MHz) 2483.500 2483.500 2484.000 2484.000 2483.500 2483.500 2484.050 2484.050 Mode 5 2452 MHz Reading
(dBuV) 60.44 Correct Factor
(dB/m)
-0.06 Result
(dBuV/m) 60.38 46.85 64.81 46.79 67.80 49.91 69.56 49.77
-0.06
-0.06
-0.06
-0.06
-0.06
-0.06
-0.06 46.79 64.75 46.73 67.74 49.85 69.50 49.71 Date:
Test By:
Limit
(dBuV/m) 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 Margin
(dB)
-13.62
-7.21
-9.25
-7.27
-6.26
-4.15
-4.50
-4.29 3m AC 120V/60Hz 26()/60%RH 06/20/2015 Eric Ou Yang Remark Ant.Polar. peak AVG peak AVG peak AVG peak AVG H / V H H H H V V V V Report Number: 1506FR2787 of 88 A Test Lab Techno Corp. 11 Antenna Measurement 11.1. Limit For intentional device, according to 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And According to 15.247 (b), if transmitting antennas of directional gain greater than 6 dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi. 11.2. Antenna Connector Construction The antenna used in this product is Dual band antenna. And the maximum Gain of this antenna is only 3 dBi. Report Number: 1506FR2788 of 88 A Test Lab Techno Corp.
1 2 3 | WIFI declaration | Cover Letter(s) | 218.25 KiB |
WIFI Channel 12 & 13 Declaration Letter To whom it may concern :
We have declared below featured for FCC equipment authorization in regard to 802.11b/g/n channel 12 &
13 operating capability for FCC ID : SWX-UAPACL Product hardware does not have the capability to operate on channel 12 & 13 Product hardware has the capability to operate on channel 12 & 13. However , these 2 channels will be disabled via software and user will not able to enable these 2 channels Product hardware has the capability to operate on channel 12 & 13. And meeting KDB 594280 D01 requirement. Pls explain detail here. _________________ Others Pls explain detail here. Please check Company Name: Ubiquiti Networks, Inc. Address : 2580 Orchard Parkway, San Jose, California United States, 95131 Name : Michael Taylor / Compliance Manager Signature :
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-06-01 | 5745 ~ 5825 | NII - Unlicensed National Information Infrastructure TX | Class II Permissive Change |
2 | 2015-08-13 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
3 | 5745 ~ 5825 | NII - Unlicensed National Information Infrastructure TX |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 | Effective |
2016-06-01
|
||||
1 2 3 |
2015-08-13
|
|||||
1 2 3 | Applicant's complete, legal business name |
Ubiquiti Inc.
|
||||
1 2 3 | FCC Registration Number (FRN) |
0012268215
|
||||
1 2 3 | Physical Address |
685 Third Avenue
|
||||
1 2 3 |
685 Third Avenue, 27th Floor
|
|||||
1 2 3 |
New York, NY
|
|||||
1 2 3 |
United States
|
|||||
app s | TCB Information | |||||
1 2 3 | TCB Application Email Address |
t******@siemic.com
|
||||
1 2 3 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 3 | Grantee Code |
SWX
|
||||
1 2 3 | Equipment Product Code |
UAPACL
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 | Name |
M******** F****
|
||||
1 2 3 | Title |
Compliance Manager
|
||||
1 2 3 | Telephone Number |
408-9********
|
||||
1 2 3 | Fax Number |
408-9********
|
||||
1 2 3 |
c******@ubnt.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 07/16/2016 | ||||
1 2 3 | 09/27/2015 | |||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 | Equipment Class | NII - Unlicensed National Information Infrastructure TX | ||||
1 2 3 | DTS - Digital Transmission System | |||||
1 2 3 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Access Point | ||||
1 2 3 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | Yes | ||||
1 2 3 | No | |||||
1 2 3 | Modular Equipment Type | Does not apply | ||||
1 2 3 | Purpose / Application is for | Class II Permissive Change | ||||
1 2 3 | Original Equipment | |||||
1 2 3 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 | Grant Comments | CIIPC to add DFS band. Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 2x2 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. | ||||
1 2 3 | Power listed is the maximum combined conducted output power. Device is 2x2 MIMO contains 20 and 40 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures | |||||
1 2 3 | Power listed is the maximum combined conducted output power. Device is approved per 15.407(a)(1)(ii) as Indoor access point. 5150-5250MHz is restricted for indoor use only. Device is 2x2 MIMO contains 20/ 40/ 80 MHz signal bandwidth. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures | |||||
1 2 3 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 | Firm Name |
A Test Lab Techno Corp.
|
||||
1 2 3 | Name |
J******** L********
|
||||
1 2 3 | Telephone Number |
886-3********
|
||||
1 2 3 | Fax Number |
886-3********
|
||||
1 2 3 |
J******@atl-lab.com.tw
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15E | 38 CC MO | 5180 | 5240 | 0.09 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15E | 38 CC MO ND | 5260 | 5320 | 0.15 | |||||||||||||||||||||||||||||||||||
1 | 3 | 15E | 38 CC MO ND | 5500 | 5700 | 0.19 | |||||||||||||||||||||||||||||||||||
1 | 4 | 15E | 38 CC MO | 5745 | 5825 | 0.166 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC MO | 2412.00000000 | 2462.00000000 | 0.1100000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15E | 38 CC MO | 5180 | 5240 | 0.09 | |||||||||||||||||||||||||||||||||||
3 | 2 | 15E | 38 CC MO | 5745 | 5825 | 0.166 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC