all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Revised User Manual | Users Manual | 5.64 MiB | May 03 2015 / April 08 2015 | |||
1 |
|
Internal Photos | Internal Photos | 5.07 MiB | May 02 2015 / April 08 2015 | |||
1 |
|
External Photos | External Photos | 2.64 MiB | May 02 2015 / April 08 2015 | |||
1 |
|
Label and Location | ID Label/Location Info | 51.62 KiB | May 02 2015 / June 03 2015 | |||
1 | RF Exposure Info | May 02 2015 / June 03 2015 | ||||||
1 | RF Exposure Info | May 02 2015 / June 03 2015 | ||||||
1 |
|
Confidentiality Request Letter | Cover Letter(s) | 164.67 KiB | May 02 2015 / June 03 2015 | |||
1 | RF Exposure Info | May 02 2015 / June 03 2015 | ||||||
1 | RF Exposure Info | May 02 2015 / June 03 2015 | ||||||
1 | Test Report | May 03 2015 / June 03 2015 | ||||||
1 | Test Report | May 03 2015 / June 03 2015 | ||||||
1 | Test Report | May 03 2015 / June 03 2015 | ||||||
1 | Test Setup Photos | May 02 2015 / April 08 2015 |
1 | Revised User Manual | Users Manual | 5.64 MiB | May 03 2015 / April 08 2015 |
LINK GPS MGMT DATA 5 GHz Carrier Backhaul Radio Model: AF-5X DATAMGMTGPSLINK Introduction Introduction Thank you for purchasing the Ubiquiti Networks airFiber 5 GHz Carrier Backhaul Radio. This Quick Start Guide is designed to guide you through the installation, show you how to access the airFiber Configuration Interface, and explain how to set up an airFiber link. This Quick Start Guide also includes the warranty terms, and is for use with airFiber X, model AF-5X. Package Contents airFiber AF-5X GPS Antenna External GPS Antenna Metal Strap Mount Cable Ties
(Qty. 2) Gigabit PoE Adapter with Mounting Bracket
(24V, 1A) LINK GPS MGMT DATA 5 GHz Carrier Backhaul Radio Model: AF-5X Power Cord Quick Start Guide TERMS OF USE: Ubiquiti radio devices must be professionally installed. Shielded Ethernet cable and earth grounding must be used as conditions of product warranty. TOUGHCable is designed for outdoor installations. It is the customers responsibility to follow local country regulations, including operation within legal frequency channels, output power, and Dynamic Frequency Selection (DFS) requirements. 1 DATAMGMTGPSLINK Hardware Overview Connects to External GPS Antenna Chain 0: Connects to
+45 on airFiber Antenna Chain 1: Connects to
-45 on airFiber Antenna LED Panel Port Cover 2 airFiber AF-5X Quick Start Guide Ports Hardware Overview Management Port Reset Button Data Port Management Port 10/100 Mbps, secured Ethernet port for configuration. In-Band Management is enabled by default in the airFiber Configuration Interface. When In-Band Management is disabled, the MGMT port is the only port that can monitor, configure, and/or update firmware. Reset Button To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is already poweredon. Data Port Gigabit PoE port for handling all user traffic and powering the device. 3 LEDs Signal LEDs Signal 4 LED will light blue when on. Signal 3 LED will light green when on. Signal 2 LED will light yellow when on. Signal 1 LED will light red when on. Bootup to airOS When powering on, the Power, GPS, Link, and Signal 1-4 LEDs light on. Once the CPU code takes over, the GPS, Link, and Signal 1-3 LEDs turn off. Signal 4 LED remains on to indicate the boot sequence is underway. Initializing airFiber Software When the airFiber application begins to boot under airOS, the Signal 4 LED goes from solidly on to a 2.5 Hz flash. This continues until the airFiber AF-5X is fully booted. Signal Level Once fully booted, the Signal 1-4 LEDs act as a bar graph showing how close the airFiber AF-5X is to ideal aiming. This is auto-scaled based on the link range, the antenna gains, and the configured TX power of the remote airFiber AF-5X. Each Signal LED has three possible states: On, Flashing, and Off. All Signal LEDs would be solidly on in an ideal link. If the link has a 1 dB loss, the Signal4 LED will flash; a 2 dB loss and the Signal 4 LED will turn off. The full bar graph LED states are shown below. 0 1 1 1 1 dB loss 4
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
-11
-12
-13 F 1 1 1 0 1 1 1 0 F 1 1 0 0 1 1 0 0 F 1 0 0 F 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 F 0 0 0 F 0 0 0 F 0 0 0 0 0 = Off, 1 = On, F = Flashing airFiber AF-5X Quick Start Guide Hardware Overview Additional LEDs LED State Off Status RF Off Short Flash*
Syncing LINK Normal Flash*
Beaconing Long Flash*
Registering On Off Operational No GPS Synchronization GPS Normal Flash*
Non-Operational (Weak Signal) On Off On Operational (Strong Signal) No Ethernet Link Ethernet Link Established Random Flashing Ethernet Activity Off On No Ethernet Link Ethernet Link Established Random Flashing Ethernet Activity Off On No Power Powered On MGMT DATA
* Short Flash (1:3 on/off cycle) Normal Flash (1:1 on/off cycle) Long Flash (3:1 on/off cycle) 5 Installation Requirements The airFiber AF-5X radio operates only with an airFiber antenna or a retrofitted RocketDish antenna. Available airFiber antenna models:
AF-5G23-S45 AF-5G30-S45 AF-5G34-S45 Available retrofit accessory for RocketDish (RD-5G30/RD-5G34):
AF-5G-OMT-S45 Other Requirements Clear line of sight between airFiber radios Clear view of the sky for proper GPS operation Vertical mounting orientation Mounting point:
At least 1 m below the highest point on the structure For tower installations, at least 3 m below the top of thetower Ground wires min. 10 AWG (5 mm2) and max. length: 1m. Asa safety precaution, ground the airFiber radio to grounded masts, poles, towers, or grounding bars. WARNING: Failure to properly ground your airFiber radio will void your warranty.
(Recommended) 2 Outdoor Gigabit PoE surge protectors Note: For guidelines about grounding and lightning protection, follow your local electrical regulatory codes. Outdoor, shielded Category 6 (or above) cabling and shielded RJ-45 connectors are required for all wired Ethernet connections. 6 airFiber AF-5X Quick Start Guide Installation Overview Installation Overview We recommend that you configure your paired airFiber AF-
5X radios before site installation. Below is an overview of the installation with specific details in the following instructions:
Connect Power over Ethernet to the DATA port, and connect an Ethernet cable between your computer and the MGMTport. Configure the device settings in the airFiber Configuration Interface. Install a ground wire and mount the airFiber AF-5X to an airFiber compatible antenna. At the installation site, install the dish antenna (see the antenna's Quick Start Guide for installation instructions). Secure the ground wire and mount the GPS antenna. Establish and optimize the RF link. Connecting Power over Ethernet 1. Lift the release latch on the bottom of the airFiber AF-5X and slide the Port Cover off. 7 2. Connect an Ethernet cable to the DATA port. 3. Connect the Ethernet cable from the DATA port to the Ethernet port labeled POE on the Gigabit PoE Adapter. 4. Connect the Power Cord to the power port on the Gigabit PoE Adapter. Connect the other end of the Power Cord to a powersource. 8 airFiber AF-5X Quick Start Guide airFiber Configuration airFiber Configuration The instructions in this section explain how to access the airFiber Configuration Interface and configure the following settings:
Wireless Mode Configure one airFiber AF-5X as the Master and the other as the Slave. Frequency Setting The operating Frequency must be the same on both the Master and the Slave. 1. Connect an Ethernet cable from your computer to the MGMT port on the airFiber AF-5X. 2. Configure the Ethernet adapter on your computer with a static IP address on the 192.168.1.x subnet. 3. Launch your web browser. Type http://192.168.1.20 in the address field and press enter (PC) or return (Mac). 9 4. The login screen will appear. Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Login. Note: U.S. product versions are locked to the U.S. Country Code to ensure compliance with FCC regulations. 5. The Main tab will appear. Click the Tools drop-down and select Link Calculator. This tool will guide you on how to best minimize bandwidth and power/interference issues. 6. Enter the requirements of your link, and then click Calculate. Adjust the values as needed to get the optimal result, and then write down the settings needed for your configuration. 7. Click the Wireless tab. 10 airFiber AF-5X Quick Start Guide airFiber Configuration 8. Configure the Basic Wireless Settings:
a. For one airFiber AF-5X, select Master as the Wireless Mode. For the other airFiber AF-5X, keep the default,Slave. b. Enter a name in the Link Name field. This should be the same on both the Master and the Slave. c. If needed, change the Channel Bandwidth, (Master) Duty Cycle, Output Power and/or Maximum Modulation Rate settings. 9. Configure the Frequency Setting. The selected Frequency must be the same on both airFiber radios. 10. Configure the Wireless Security:
a. Select the AES Key Type, HEX or ASCII. b. For the Key field:
- HEX Enter 16 bytes (eight, 16-bit HEX values: 0-9, A-F, or a-f). You can omit zeroes and use colons, similar to the IPv6 format. Note: The airFiber Configuration Interface supports IPv6 formats excluding dotted quad and "::"
(double-colon) notation.
- ASCII Enter a combination of alphanumeric characters (0-9, A-Z, or a-z). 11. Click Change and then click Apply. 11 12. In-Band Management is enabled by default, so each airFiber radio must have a unique IP Address. ( If the airFiber radios use the same IP Address, then you may lose access to the airFiber radios via the DATA ports.) Click the Network tab. a. For the Management IP Address option:
- DHCP Keep the default, DHCP, to use DHCP reservation on your router to assign a unique IP Address.
- Static Change the IP Address, Netmask, and other settings to make them compatible with your network. b. Click Change and then click Apply. Repeat the instructions in the airFiber Configuration section on your other airFiber AF-5X. After you have configured the airFiber radios, disconnect them and move them to your installation site. 12 airFiber AF-5X Quick Start Guide Hardware Installation Hardware Installation Install a Ground Wire 1. Remove the nut from the Ground Bonding Point located on the back of the airFiber AF-5X. Ground Bonding Point 2. Attach a ground wire (min. 8 AWG or 10 mm2) to the lug and replace the nut to secure the wire. 3. At the installation site, secure the other end of the ground wire to a grounded mast, pole, tower, or grounding bar. WARNING: Failure to properly ground your airFiberAF-5X will void your warranty. Note: The ground wire should be as short as possible and no longer than one meter in length. 13 Mount to an Antenna The airFiber AF-5X can be mounted to an airFiber antenna or a retrofitted RocketDish. The airFiber Antenna (AF-5G30-S45) is shown in the following steps:
1. Attach the airFiber AF-5X to the Mounting Bracket. a. Align the mounting tabs on the back of the airFiber AF-5X with the Mounting Bracket. b. Slide the airFiber AF-5X down to lock it into place. 14 airFiber AF-5X Quick Start Guide Hardware Installation 2. Attach the RF Cables from the antenna feed to the RF connectors on the airFiber AF-5X in this combination: +45 to Chain 0 and -45 to Chain 1. 3. Attach the External GPS Antenna to the RF connector labeled GPS. Then place the magnetic External GPS Antenna on the bracket (this is temporary; you will mount the External GPS Antenna on the GPS Antenna Mount at the site). 15 4. Attach the protective shroud. a. Align the hash mark on the top of the shroud with the notch on the dish antenna. b. Rotate the shroud clockwise until it locks into place. 16 airFiber AF-5X Quick Start Guide Hardware Installation Mount the External GPS Antenna Locate a mounting point that has a clear view to the sky, and is above and as far away as possible from the airFiber AF-5X. 1. Attach the GPS Antenna Mount to the pole using the metal strap, or attach it to a wall using the appropriate fasteners
(notincluded). 2. Place the External GPS Antenna on the mount. 3. Secure the cable of the External GPS Antenna to the mount with a Cable Tie. 17 Connecting Power over Ethernet 1. Lift the release latch on the bottom of the airFiber AF-5X and slide the Port Cover off. 2. Connect an outdoor, shielded Ethernet cable to the DATA port. 18 airFiber AF-5X Quick Start Guide 3. Connect the other end of the cable from the DATA port to the Ethernet port labeled POE on the Gigabit PoE Adapter. Hardware Installation 4. Connect an Ethernet cable from your network to the Ethernet port labeled LAN on the Gigabit PoE Adapter. 5. Connect the Power Cord to the power port on the Gigabit PoE Adapter. Connect the other end of the Power Cord to a power source. 19 Mount the PoE Adapter (Optional) 1. Remove the Mounting Bracket from the adapter by sliding the bracket downward. 2. Place the Mounting Bracket at the desired location and mark the holes for the fasteners. Pre-drill the holes if necessary, then secure the bracket to wall using two fasteners (not included). 3. Attach the Gigabit PoE Adapter to the bracket by aligning the four slots and tabs, and then slide the adapter downward. 20 airFiber AF-5X Quick Start Guide Hardware Installation Surge Protection For added protection, install two surge suppressors, such as the Ubiquiti Ethernet Surge Protector, model ETH-SP, at the end of each link. Install the first surge protector within one meter of the airFiber DATA port, and install the second surge protector at the ingress point of the location housing the wired network equipment. GPS Antenna AF-5X Mounted on AF-5G30-S45 m 1
. x a M Ground to Pole, Tower, or Grounding Block:
Max. 1 m from AF-5X ETH-SP ETH-SP EdgeRouter Gigabit PoE Adapter Power Source 21 Alignment Tips To accurately align the airFiber radios for best performance, you MUST align only one end of the link at a time. You may need to use additional hardware to compensate for issues such as the improper orientation of a mounting pole or significant elevation differences between airFiber radios. Establishing a Link Adjust the positions of the Master and the Slave to establish a link. The following guide features the airFiber antenna, AF-5G30-S45:
Note: The Master must be aimed first at the Slave because the Slave does not transmit any RF signal until it detects transmissions from the Master. 1. Master Visually aim the Master at the Slave. To adjust the Master's position:
a. Loosen the four pole clamp nuts, and rotate the airFiber antenna on the pole to align the azimuth. 22 airFiber AF-5X Quick Start Guide b. Loosen the six elevation bolts, and use the hex nut on the elevation rod to adjust the elevation. Alignment Note: Do NOT make simultaneous adjustments on the Master and Slave. 2. Slave Visually aim the Slave at the Master. To adjust the Slave's position:
a. Loosen the four pole clamp nuts, and rotate the airFiber antenna on the pole to align the azimuth. b. Loosen the six elevation bolts, and use the hex nut on the elevation rod to adjust the elevation. 3. Check to see if a link is established. Ensure that the LINK LED is solidly lit green and the Signal LEDs of the Slave are displaying signal levels. 23 4. Slave Aim the Slave at the Master to achieve the strongest signal level on the Master. Note: Refer to the Signal Level table on page 4 for details on the signal values. Note: Maximum signal strength can best be achieved by iteratively sweeping through both azimuth and elevation. 5. Master Aim the Master at the Slave to achieve the strongest signal level on the Slave. 6. Repeat steps 4 and 5 until you achieve an optimal link, with all four Signal LEDs solidly lit. This ensures the best possible data rate between the airFiber radios. 7. Lock the alignment on both airFiber antennas by tightening all the nuts and bolts. 8. Observe the Signal LEDs of each airFiber radio to ensure that the values remain constant while tightening the nuts and bolts. If any LED value changes during the locking process, loosen the nuts and bolts, finalize the alignment of each airFiber antenna again, and retighten the nuts and bolts. Refer to the airFiber AF-5X User Guide for details on the airFiber Configuration Interface. 24 airFiber AF-5X Quick Start Guide Installer Compliance Responsibility Installer Compliance Responsibility Devices must be professionally installed and it is the professional installers responsibility to make sure the device is operated within local country regulatory requirements. The Output Power, Antenna Gain, Cable Loss, and Frequency fields are provided to the professional installer to assist in meeting regulatory requirements. 25 Specifications Dimensions Weight RF Connectors GPS Antenna Max. Conducted TX Power Power Supply Power Method Mounting Certifications Operating Temperature Networking Interface Data Port Management Port System Maximum Throughput Encryption OS Wireless Modes Radio Operating Frequency Frequency Accuracy Channel Bandwidth 26 airFiber AF-5X 224 x 82 x 48 mm (8.82 x 3.23 x 1.89") 0.35 kg (0.77 lb)
(2) RP-SMA Weatherproof (CH0, CH1)
(1) SMA Weatherproof (GPS) External, Magnetic Base 26 dBm
(Depending on Regulatory Region) 24V, 1A PoE Gigabit Adapter (Included) Passive Power over Ethernet Rocket Mount Compatible GPS Pole Mount (Included) FCC Part 15.407 CE EN 302502 v1.2.1, EN 301 893 v1.7.1
-40 to 55 C (-40 to 131 F)
(1) 10/100/1000 Ethernet Port
(1) 10/100 Ethernet Port 500 Mbps 128-bit AES airOS F Master/Slave 5150-5925 MHz
(Depends on Regulatory Region) 2.5 ppm without GPS Synchronization 0.2 ppm with GPS Synchronization 10 MHz, 20 MHz, 30 MHz, 40 MHz, 50 MHz Selectable airFiber AF-5X Quick Start Guide Electrical Safety Information Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturers label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. 27 Limited Warranty UBIQUITI NETWORKS, Inc (UBIQUITI NETWORKS) warrants that the product(s) furnished hereunder (the Product(s)) shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation. UBIQUITI NETWORKS sole and exclusive obligation and liability under the foregoing warranty shall be for UBIQUITI NETWORKS, at its discretion, to repair or replace any Product that fails to conform to the above warranty during the above warranty period. The expense of removal and reinstallation of any Product is not included in this warranty. The warranty period of any repaired or replaced Product shall not extend beyond its original term. Warranty Conditions The above warranty does not apply if the Product:
(I) has been modified and/or altered, or an addition made thereto, except by Ubiquiti Networks, or Ubiquiti Networks authorized representatives, or as approved by Ubiquiti Networks in writing;
(II) has been painted, rebranded or physically modified in any way;
(III) has been damaged due to errors or defects in cabling;
(IV) has been subjected to misuse, abuse, negligence, abnormal physical, electromagnetic or electrical stress, including lightning strikes, or accident;
(V) has been damaged or impaired as a result of using third party firmware;
(VI) has no original Ubiquiti MAC label, or is missing any other original Ubiquiti label(s); or
(VII) has not been received by Ubiquiti within 30 days of issuance of the RMA. In addition, the above warranty shall apply only if: the product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation; all Ethernet cabling runs use CAT5 (or above), and for outdoor installations, shielded Ethernet cabling is used, and for indoor installations, indoor cabling requirements are followed. WARNING: Failure to properly ground your airFiber AF-
5X will void your warranty. (Please follow the instructions on page 12 for installation of the ground wires.) Returns No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS during the warranty period, and the Products being received at UBIQUITI NETWORKS facility freight prepaid in accordance with the RMA process of UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned freight collect or subject to disposal. Information on the RMA process and obtaining an RMA number can be found at: www.ubnt.com/support/warranty. 28 airFiber AF-5X Quick Start Guide Limited Warranty Disclaimer EXCEPT FOR ANY EXPRESS WARRANTIES PROVIDED HEREIN, UBIQUITI NETWORKS, ITS AFFILIATES, AND ITS AND THEIR THIRD PARTY Data, SERVICE, SOFTWARE AND HARDWARE PROVIDERS HEREBY DISCLAIM AND MAKE NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, REPRESENTATIONS, GUARANTEES, OR WARRANTIES OF MERCHANTABILITY, ACCURACY, QUALITY OF SERVICE OR RESULTS, AVAILABILITY, SATISFACTORY QUALITY, LACK OF VIRUSES, QUIET ENJOYMENT, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT AND ANY WARRANTIES ARISING FROM ANY COURSE OF DEALING, USAGE OR TRADE PRACTICE IN CONNECTION WITH SUCH PRODUCTS AND SERVICES. BUYER ACKNOWLEDGES THAT NEITHER UBIQUITI NETWORKS NOR ITS THIRD PARTY PROVIDERS CONTROL BUYERS EQUIPMENT OR THE TRANSFER OF Data OVER COMMUNICATIONS FACILITIES, INCLUDING THE INTERNET, AND THAT THE PRODUCTS AND SERVICES MAY BE SUBJECT TO LIMITATIONS, INTERRUPTIONS, DELAYS, CANCELLATIONS AND OTHER PROBLEMS INHERENT IN THE USE OF COMMUNICATIONS FACILITIES. UBIQUITI NETWORKS, ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS, DELAYS, CANCELLATIONS, DELIVERY FAILURES, Data LOSS, CONTENT CORRUPTION, PACKET LOSS, OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING. In addition, UBIQUITI NETWORKS does not warrant that the operation of the Products will be error-free or that operation will be uninterrupted. In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance, including coverage, buyers selection of products (including the Products) for buyers application and/or failure of products (including the Products) to meet government or regulatory requirements. Limitation of Liability EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN NO EVENT WILL UBIQUITI OR ITS SUBSIDIARIES, AFFILIATES OR SUPPLIERS BE LIABLE FOR DIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES
(INCLUDING LOST PROFIT, LOST Data, OR DOWNTIME COSTS), ARISING OUT OF THE USE, INABILITY TO USE, OR THE RESULTS OF USE OF THE PRODUCT, WHETHER BASED IN WARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY, AND WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Note Some countries, states and provinces do not allow exclusions of implied warranties or conditions, so the above exclusion may not apply to you. You may have other rights that vary from country to country, state to state, or province to province. Some countries, states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages, so the above limitation may not apply to you. EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW, THESE WARRANTY TERMS DO NOT EXCLUDE, RESTRICT OR MODIFY, AND ARE IN ADDITION TO, THE MANDATORY STATUTORY RIGHTS APPLICABLE TO THE LICENSE OF ANY SOFTWARE (EMBEDDED IN THE PRODUCT) TO YOU. The United Nations Convention on Contracts for the International Sale of Goods shall not apply to any transactions regarding the sale of the Products. 29 Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to Increase the separation between the equipment and receiver. which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This radio transmitter (FCC: SWX-AF5X) has been approved by FCC to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Dish model: AF-5G23-S45, gain: 23dBi, type: Parabolic Dish model(s): AF-5G30-S45/RD-5G30(w/ AF-5G-OMT), gain: 30dBi, type: Parabolic Dish model(s): AF-5G34-S45/RD-5G34(w/ AF-5G-OMT), gain: 34dBi, type: Parabolic DFS Regulatory Regions Operation in DFS regulatory regions requires an antenna with minimum gain of 23 dBi. 30 airFiber AF-5X Quick Start Guide Compliance Industry Canada CAN ICES-3(B)/NMB-3(B) To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that permitted for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. This radio transmitter (IC: 6545A- AF5X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Dish model: AF-5G23-S45, gain: 23dBi, type: Parabolic Dish model(s): AF-5G30-S45/RD-5G30(w/ AF-5G-OMT), gain: 30dBi, type: Parabolic Dish model(s): AF-5G34-S45/RD-5G34(w/ AF-5G-OMT), gain: 34dBi, type: Parabolic DFS Regulatory Regions Operation in DFS regulatory regions requires an antenna with minimum gain of 23 dBi. CAN ICES-3(B)/NMB-3(B) Pour rduire le risque dinterfrence aux autres utilisateurs, le type dantenne et son gain doivent tre choisies de faon que la puissance isotrope rayonne quivalente (PIRE) ne dpasse pas ce qui est ncessaire pour une communication russie. Cet appareil est conforme la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes:
1. Cet appareil ne peut pas provoquer dinterfrences et 2. Cet appareil doit accepter toute interfrence, y compris les interfrences qui peuvent causer un mauvais fonctionnement du dispositif. 31 Les utilisateurs devraient galement noter que radars haute puissants sont allous comme principaux utilisateurs (cest--dire les utilisateurs de priorit) des bandes 5250-5350 MHz et 5650 5850 MHz et que ces radars pourraient causer des interfrences ou dommages aux dispositifs LAN. Cet metteur radio (IC: IC: 6545A-AF5X) a t approuve par Industrie Canada pour lexploitation avec lantenne types numrs ci-dessous avec le gain maximal admissible et requis limpdance de lantenne pour chaque type dantenne indiqu. Types dantenne non inclus dans cette liste, ayant un gain suprieur au gain maximal indiqu pour ce type, sont strictement interdits pour une utilisation avec cet appareil. Immdiatement suite la remarque, le fabricant doit fournir une liste de tous les types dantenne approuv pour une utilisation avec lmetteur, ce qui indique le gain maximal dantenne permis (en dBi) et requis dimpdance pour chacun. Parabolique modle: AF-5G23-S45, gain: 23dBi, type: Parabolique Parabolique modle(s): AF-5G30-S45/RD-5G30(w/ AF-5G-OMT), gain: 30dBi, type: Parabolique Parabolique modle(s): AF-5G34-S45/RD-5G34(w/ AF-5G-OMT), gain: 34dBi, type: Parabolique Rgions Rglementaires DFS Opration dans les rgions rglementaires DFS ncessite une antenne avec un gain minimum de 23 dBi. RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 126 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter. Les antennes utilises pour ce transmetteur doivent tre install en considrant une distance de sparation de toute personnes dau moins 126cm et ne doivent pas tre localis ou utilis en conflit avec tout autre antenne ou transmetteur. Australia and New Zealand Warning: This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Alert Sign (!) Follows CE Marking Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking. 32 airFiber AF-5X Quick Start Guide RoHS/WEEE Compliance Statement Compliance English European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. Deutsch Die Europische Richtlinie 2002/96/EC verlangt, dass technische Ausrstung, die direkt am Gert und/oder an der Verpackung mit diesem Symbol versehen ist, nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt von regulrem Haushaltmll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gert und andere elektrische und elektronische Gerte ber die dafr zustndigen und von der Regierung oder rtlichen Behrden dazu bestimmten Sammelstellen zu entsorgen. Ordnungsgemes Entsorgen und Recyceln trgt dazu bei, potentielle negative Folgen fr Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgerte bentigen, wenden Sie sich bitte an die rtlichen Behrden oder stdtischen Entsorgungsdienste oder an den Hndler, bei dem Sie das Produkt erworben haben. Espaol La Directiva 2002/96/CE de la UE exige que los equipos que lleven este smbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El smbolo indica que el producto en cuestin debe separarse de los residuos domsticos convencionales con vistas a su eliminacin. Es responsabilidad suya desechar este y cualesquiera otros aparatos elctricos y electrnicos a travs de los puntos de recogida que ponen a su disposicin el gobierno y las autoridades locales. Al desechar y reciclar correctamente estos aparatos estar contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas. Si desea obtener informacin ms detallada sobre la eliminacin segura de su aparato usado, consulte a las autoridades locales, al servicio de recogida y eliminacin de residuos de su zona o pregunte en la tienda donde adquiri el producto. 33 Franais La directive europenne 2002/96/CE exige que lquipement sur lequel est appos ce symbole sur le produit et/ou son emballage ne soit pas jet avec les autres ordures mnagres. Ce symbole indique que le produit doit tre limin dans un circuit distinct de celui pour les dchets des mnages. Il est de votre responsabilit de jeter ce matriel ainsi que tout autre matriel lectrique ou lectronique par les moyens de collecte indiqus par le gouvernement et les pouvoirs publics des collectivits territoriales. Llimination et le recyclage en bonne et due forme ont pour but de lutter contre limpact nfaste potentiel de ce type de produits sur lenvironnement et la sant publique. Pour plus dinformations sur le mode dlimination de votre ancien quipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des dchets, ou lendroit o vous avez achet le produit. Italiano La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sullimballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. responsabilit del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per lambiente e per la salute dellessere umano. Per ricevere informazioni pi dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto. 34 airFiber AF-5X Quick Start Guide Declaration of Conformity Declaration of Conformity esky
[Czech]
Dansk
[Danish]
Nederlands
[Dutch]
English Eesti
[Estonian]
Suomi
[Finnish]
Franais
[French]
Deutsch
[German]
[Greek]
Magyar
[Hungarian]
slenska
[Icelandic]
UBIQUITI NETWORKS tmto prohla uje, e tento UBIQUITI NETWORKS device, je ve shod se zkladnmi po adavky a dal mi p slu n mi ustanovenmi sm rnice 1999/5/ES. Undertegnede UBIQUITI NETWORKS erklrer herved, at flgende udstyr UBIQUITI NETWORKS device, overholder de vsentlige krav og vrige relevante krav i direktiv 1999/5/EF. Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI NETWORKS device, in overeenstemming is met de essentile eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Bij deze verklaart UBIQUITI NETWORKS dat deze UBIQUITI NETWORKS device, voldoet aan de essentile eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC. Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI NETWORKS device, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Kesolevaga kinnitab UBIQUITI NETWORKS seadme UBIQUITI NETWORKS device, vastavust direktiivi 1999/5/E phinuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele stetele. UBIQUITI NETWORKS vakuuttaa tten ett UBIQUITI NETWORKS device, tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen. Par la prsente UBIQUITI NETWORKS dclare que lappareil UBIQUITI NETWORKS, device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Hiermit erklrt UBIQUITI NETWORKS, dass sich dieses UBIQUITI NETWORKS Gert in bereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. (BMWi) UBIQUITI NETWORKS UBIQUITI NETWORKS device, 1995/5/. Alulrott, UBIQUITI NETWORKS nyilatkozom, hogy a UBIQUITI NETWORKS device, megfelel a vonatkoz alapvet kvetelmnyeknek s az 1999/5/EC irnyelv egyb elrsainak. Hr me l sir UBIQUITI NETWORKS yfir v a UBIQUITI NETWORKS device, er samrmi vi grunnkrfur og a rar krfur, sem ger ar eru tilskipun 1999/5/EC. 35 Italiano
[Italian]
Latviski
[Latvian]
Lietuvikai
[Lithuanian]
Malti
[Maltese]
Norsk
[Norwegian]
Slovensky
[Slovak]
Svenska
[Swedish]
Espaol
[Spanish]
Polski
[Polish]
Portugus
[Portuguese]
Romn
[Romanian]
Con la presente UBIQUITI NETWORKS dichiara che questo UBIQUITI NETWORKS device, conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Ar o UBIQUITI NETWORKS deklar, ka UBIQUITI NETWORKS ierce, atbilst Direktvas 1999/5/EK btiskajm prasbm un citiem ar to saisttajiem noteikumiem. UBIQUITI NETWORKS deklaruoja, kad is UBIQUITI NETWORKS renginys atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Hawnhekk, UBIQUITI NETWORKS, jiddikjara li dan UBIQUITI NETWORKS device, jikkonforma mal- ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid-Dirrettiva 1999/5/EC. UBIQUITI NETWORKS erklrer herved at utstyret UBIQUITI NETWORKS device, er i samsvar med de grunnleggende krav og vrige relevante krav i direktiv 1999/5/EF. UBIQUITI NETWORKS t mto vyhlasuje, e UBIQUITI NETWORKS device, sp a zkladn po iadavky a v etky prslu n ustanovenia Smernice 1999/5/ES. Hrmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device, str I verensstmmelse med de vsentliga egenskapskrav och vriga relevanta bestmmelser som framgr av direktiv 1999/5/EG. Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device, cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Niniejszym, firma UBIQUITI NETWORKS o wiadcza, e produkt serii UBIQUITI NETWORKS device, spenia zasadnicze wymagania i inne istotne postanowienia Dyrektywy 1999/5/EC. UBIQUITI NETWORKS declara que este UBIQUITI NETWORKS device, est conforme com os requisitos essenciais e outras disposies da Directiva 1999/5/CE. Prin prezenta, UBIQUITI NETWORKS declar c acest dispozitiv UBIQUITI NETWORKS este n conformitate cu cerinele eseniale i alte prevederi relevante ale Directivei 1999/5/CE. 36 PH020315 airFiber AF-5X Quick Start Guide w w w . u b n t . c o m support.ubnt.com Support Community community.ubnt.com Downloads downloads.ubnt.com 2015 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, UbiquitiNetworks, the UbiquitiU logo, the Ubiquiti beam logo, airFiber, airOS, RocketDish, TOUGHCable, and xRT are trademarks or registered trademarks of UbiquitiNetworks,Inc. in the United States and inother countries. All other trademarks are the property of their respective owners.
*640-00158-01*
640-00158-01
1 | Confidentiality Request Letter | Cover Letter(s) | 164.67 KiB | May 02 2015 / June 03 2015 |
In reference to the application under FCC ID: SWX-AF5X, and pursuant to Sections 0.457(d)1(ii) and 0.459 of the Commissions Rules, Ubiquiti Networks hereby requests permanent confidential treatment of the accompanying information as outlined below:
Date:2015/1/12 MET Laboratories, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230-3453 RE: Request for Confidentiality Block Diagram Schematics Theory of Operation Parts List & Placement/BOM Software Security Description Antenna Specifications External Photos Internal Photos Test Setup Photos User Manual Sincerely, Ubiquiti Networks, Inc. Compliance Contact The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to Ubiquiti Networks and provide unjustified benefits to its competitors. In addition to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commissions policy, in order to comply with the marketing regulations in 47 CFR 2.803 and the important rules in 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short term confidentiality on the following attachments until 180 days from grant date. It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Ubiquiti Networks understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. 2580 Orchard Parkway San Jose, CA 95131 www.ubnt.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-03-06 | 5730 ~ 5845 | NII - Unlicensed National Information Infrastructure TX | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2015-03-06
|
||||
1 | Applicant's complete, legal business name |
Ubiquiti Inc.
|
||||
1 | FCC Registration Number (FRN) |
0012268215
|
||||
1 | Physical Address |
685 Third Avenue
|
||||
1 |
685 Third Avenue, 27th Floor
|
|||||
1 |
New York
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@metlabs.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
SWX
|
||||
1 | Equipment Product Code |
AF5X
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M****** F****
|
||||
1 | Title |
Compliance Manager
|
||||
1 | Telephone Number |
408-9********
|
||||
1 | Fax Number |
408-9********
|
||||
1 |
c******@ubnt.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 08/04/2015 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | Yes | ||||
1 | Equipment Class | NII - Unlicensed National Information Infrastructure TX | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Digital Transmission System | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | Yes | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power output listed is aggregate conducted. Device operates with specific antennas in a Point-to-Point, 2 x 2 MIMO configuration as described in this filing. This device supports 10 MHZ, 20 MHz, 30 MHz, 40 MHz, and 50 MHz BW modes. The antenna(s) used with this transmitter must be professionally installed and provide a minimum of 118cm separation from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Eurofins MET Laboratories, Inc.
|
||||
1 | Name |
J**** F****
|
||||
1 | Telephone Number |
41094********
|
||||
1 | Fax Number |
41035********
|
||||
1 |
j******@metlabs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15E | 38 MO | 5160 | 5245 | 0.057 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15E | 38 CC | 5255 | 5342 | 0.005 | |||||||||||||||||||||||||||||||||||
1 | 3 | 15E | 38 CC | 5475 | 5720 | 0.005 | |||||||||||||||||||||||||||||||||||
1 | 4 | 15E | 38 CC | 5730 | 5845 | 0.771 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC