all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User guide | Users Manual | 1.90 MiB | January 20 2022 / January 24 2022 | |||
1 |
|
Internal photos | Internal Photos | 1.69 MiB | January 20 2022 / January 24 2022 | |||
1 |
|
External photos | External Photos | 1.52 MiB | January 20 2022 / January 24 2022 | |||
1 |
|
label and location | ID Label/Location Info | 1.35 MiB | January 20 2022 / January 24 2022 | |||
1 |
|
Authorisation letter | Cover Letter(s) | 173.23 KiB | January 20 2022 / January 24 2022 | |||
1 | Block diagram | Block Diagram | January 20 2022 | confidential | ||||
1 | BoM1 | Parts List/Tune Up Info | January 20 2022 | confidential | ||||
1 | BoM2 | Parts List/Tune Up Info | January 20 2022 | confidential | ||||
1 | BoM3 | Parts List/Tune Up Info | January 20 2022 | confidential | ||||
1 |
|
Confidentiality request | Cover Letter(s) | 242.12 KiB | January 20 2022 / January 24 2022 | |||
1 |
|
Model similarity | Cover Letter(s) | 179.92 KiB | January 20 2022 / January 24 2022 | |||
1 | Operating description | Operational Description | January 20 2022 | confidential | ||||
1 | PCB layout | Schematics | January 20 2022 | confidential | ||||
1 |
|
RF exposure report | RF Exposure Info | 82.22 KiB | January 20 2022 / January 24 2022 | |||
1 | Schematics1 | Schematics | January 20 2022 | confidential | ||||
1 | Schematics2 | Schematics | January 20 2022 | confidential | ||||
1 | Schematics3 | Schematics | January 20 2022 | confidential | ||||
1 |
|
Test report | Test Report | 2.28 MiB | January 20 2022 / January 24 2022 | |||
1 |
|
Test setup photos | Test Report | 550.19 KiB | January 20 2022 / January 24 2022 |
1 | User guide | Users Manual | 1.90 MiB | January 20 2022 / January 24 2022 |
Table of Contents Copyright and Declaration.................... 1 Preface ................................... 5 Symbols................................... 6 Warnings and Precautions ................... 7 1. Instrument Introduction ................... 11 1.1 Instrument Features................. 11 1.2 Intended Use....................... 13 1.3 Contraindication .................... 14 1.4 Specifications ...................... 14 1.5 Structure and Principle .............. 17 1.6 Appearance and Components ........ 19 2. Installation.............................. 23 2.1 Action upon delivery................. 23 2.2 Instructions for use.................. 23 2.3 Installing the battery................. 28 2.4 Connect printer ..................... 29 2.5 Loading Thermal Print Paper ......... 30 3. Usage Precautions ...................... 33 3.1 Sample Usage Precautions .......... 33 3.2 Reagent Strips Usage Precautions .... 35 3.3 Instrument Usage Precautions ........ 36 4. The Instrument Use Procedures ........... 39 4.1 Shut-down procedure ............... 39 4.2 Routine Measurement ............... 40 5. Instrument Checkup ..................... 47 5.1 Checkup .......................... 47 5.2 Checkup Operate ................... 48 6. Function Introduction..................... 50 6.1 Function Introduction of Printer ....... 50 6.2 Test Function....................... 50 6.3 Introduction of Testing Result ......... 51 6.4 Reviewing Results .................. 53 6.5 Setting ............................ 54 6.6 How to connect mobile APP .......... 55 6.7 Mobile APP introduction ............. 57 7. Maintenance ............................ 59 7.1 Precautions ........................ 59 7.2 General cleaning ................... 59 7.3 Cleaning the strip tray (Daily) ......... 59 8. Storage and Handling .................... 61 8.1 Handling .......................... 61 8.2 Storage ........................... 61 9. Troubleshooting ......................... 62 Appendix ................................. 65 Copyright and Declaration Copyright URIT Medical Electronic Co., Ltd. All contents in this manual were strictly compiled according to related laws and regulations in China, as well as the specific condition of UC-32A urine analyzer, covering all the updated information before printing. URIT is fully responsible for the revision and explanation of the manual, and reserves the right to renovate the relevant contents without separate notification. Some of the demonstration pictures are for reference and subject to real object if any differences. All the information included is protected by copyright. No part of this document may be reproduced, stored or transmitted in any form or by any means unless written authorization by URIT. All instructions must be followed strictly in operation. In no event should URIT be responsible for failures, errors and other liabilities resulting from users 1 noncompliance with the procedures and precautions outlined herein. Limitation of Liability URIT warrants to the original purchaser that this instrument will be free from defects in materials and workmanship for a period of one year from the later of the date of original purchase or installation. URIT assumes no liability in the following situations even during the period of warranty. 1. Failure due to abuse the instrument or neglect the maintenance. 2. Use reagents and accessories other than manufactured or recommended by URIT. 3. Failure due to operate not under the instructions described in the manual. 4. Replace accessories not specified by URIT, or after maintenance or repair by a service agent not approved or authorized by URIT. 2 NOTE:
URIT makes no warranties, either expresses or implied, as to product quality, performance, and value as a commodity or applicability for any particular purpose. Technical service and troubleshooting are provided by URIT. If the instrument has malfunction, please contact the agency authorized by URIT. CAUTION:
THE INSTRUMENT IS FOR PROFESSIONAL AND PRESCRIPTION USE ONLY. URIT Medical Electronic Co., Ltd. Address: No.D-07 Information Industry District, High-Tech Zone, Guilin, Guangxi 541004, P.R.China Tel: +86(773)2288586 Fax: +86(773)2288560 3 Web: www.urit.com Email: service@uritest.com Supplied by: URIT Medical Electronic Co., Ltd. VERSION: 12/2020 4 Preface This operating manual describes in detail the installation, structure, operation and maintenance of UC-32A urine analyzer (Hereinafter we simple call the UC-32A urine analyzer as Instrument). Please carefully read through this manual before using the instrument and follow the instructions presented in the manual to perform measurements. Caution This instrument uses urine as sample, which may carry pathogenic microbes that can cause infectious disease. Please wear protective gloves to prevent exposure to pathogenic microbes during operation or maintenance. If the sample is in contact with the skin, please clean it in time. The instrument operator must read the manual carefully before operating instrument. 5 Symbols Consult instructions for use Protect from heat and radioactive sources Electrical and electronic products recycling symbol Environment-Friendly Use Period Authorized representative in European Community Class equipment direct-current
(DC) Caution Biological risks Manufacturer Serial number Keep dry Use-by date
Positive pole -
6 Date of manufacture In Vitro Diagnostic medical device Negative pole Warnings and Precautions n The instrument power supply is 5V DC or two AA alkaline batteries, please pay attention to the battery polarity when installing the battery. n Only the accompanying AC adapter is allowed. n Remove the battery from the instrument when the battery is used up or the instrument is not used for a long time. n Replace the waste batteries please in accordance with the relevant local laws and regulations properly handled. n Install the instrument in a ventilated room where temperature is maintained between 15~30 and humidity is less than 80%. n When the instrument is moved to a different environment, leave it for one hour until it returns to the room 7 temperature before measurement. n Leave at least 10 cm space to the front side of the instrument. n Use only the URIT reagent strips and carefully read through the package inserts of the reagent strips. n Do not use attachments that are not provided or recommended by the manufacturer. n Turn off the power switch and unplug the power cord immediately if the instrument gives off odor or smoke, otherwise it will cause fire, electric shock or injury. If this happens, please contact the after-sale service department. n Do not expose the instrument to corrosive and flammable gas, direct sunlight or wind. n The instrument should be placed on a level, stable and vibration-free worktable. 8 n Do not place in the storage of chemicals or near items that produce corrosive gases and electromagnetic interference. n Do not repair or rebuild the instrument by yourself, in order to avoid damage to the instrument or injury. n Keep the instrument away from magnetic sources or devices that generate electromagnetic wave. n Keep the instrument away from liquids, dust and physical shocks or impacts. n After the instrument is abandoned, it should be handled in accordance with the regulations on Recycling and disposal of waste Electrical and Electronic products. n When preparing and testing samples, please be careful. If the samples contact with skin carelessly, please wash them in time. n Used samples, test strips, strip trays, 9 protective gloves, etc., should be handled in accordance with the relevant local regulations. n The result tested by the instrument can only be applied to screening some related diseases in the group according to the detection results of human urine. It cant be used directly as evidence for diagnosing diseases. 10 1. Instrument Introduction 1.1 Instrument Features Compact and portable The instrument weighs 190g (battery-free) and only has the size of a palm, making it easy to carry Simple operation Insert the strip tray into the tray conveyor and the instrument will test automatically. The test results are displayed on display screen, and it can also be sent to external devices through the Bluetooth or USB interface. Color display screen The color display screen makes the display information richer and the abnormal detection results easier to recognize. Corrective features 1) Eliminate the effect of chromaturia by using the color correction test pad. 11 2) Correct specific gravity based on pH readings. Convenient daily maintenance Strip tray can be easily detached for daily cleaning. Using LED as light source, so you do not need to replace sense light. Automatic identification of reagent strip type The instrument can automatically identify the type of the reagent strip and is more intelligent. Auto update of memory Up to 1200 samples can be stored in memory. You can query or via Bluetooth interface send test results to an external device. When results exceed 1200, the oldest will be deleted automatically and record the new data. Separation-Type Printer (Optional) Separation-Type Printer, automatic printing test results after testing. Normal work without external power supply The instrument have two AA alkaline batteries , it can continuously test 300 samples 12 Accuracy of the reagent strip for urine analysis No more than one order of magnitude of difference between the test result and the corresponding reference value, and no reverse difference shall occur. A positive reference solution shall not produce a negative result, and a negative reference solution shall not produce a positive result. 1.2 Intended Use The instrument can be used in combination with urine reagent strips for semi-quantitative or qualitative detection of biochemical components in urine samples, which can provide reference for clinical examination and diagnosis. The items that can be detected are Urobilinogen (URO), Bilirubin
(BIL), Ketone (KET), Blood (BLD), Protein (PRO), Nitrite (NIT), Leukocyte (LEU), Glucose (GLU), Specific Gravity (SG), pH, Microalbumin (MA), Creatinine (CR), Vitamin C (VC) and Calcium (Ca). The instrument applies to medical institutions for 13 the urine test. The instrument is for professional, in vitro diagnostic use (
). The result tested by the instrument can only be applied to screening some related diseases in the group according to the detection results of human urine. It cant be used directly as evidence for diagnosing diseases. 1.3 Contraindication None. 1.4 Specifications 1.4.1 Performance of the instrument n Reagent Strips: HC-2U, HC-3U, HC-4U, HC-6U, HC-ACR, HC-4K, HC-5K, HC-6K, HC-1S, HC-3S, HC-4S, HC-6S, HC-1D, HC-2D, HC-4D, HC-6D, HC-8T, HC-10T, HC-10TA, HC-12TA, HC-14TA. n Analytes: Leukocyte (LEU), Ketone (KET), Nitrite (NIT), Urobilinogen (URO), Bilirubin
(BIL), Protein
(PRO), Glucose
(GLU), Specific Gravity (SG), Blood (BLD), pH, 14 n n n n n n n Creatinine
(CR), Microalbumin
(MA), Vitamin C (VC) and Calcium (Ca). Measuring Principle:Reflectance photometry. Measurement Wavelength: 470 nm, 550 nm, 620 nm, 720 nm. Sample Supply Method: Manual dipping. Throughput: 501 s/test. Measuring Mode:
Automatic single measuring mode. n Display: Color display screen, which can display operational information of the instrument and test results, etc. Memory: Up to 1200 samples. Specific gravity Correction: Automatically corrected based on pH readings. n Chromaturia Correction:
Automatically corrected by color correction test pad. n Data Output: Test results can be transmitted to external devices via Bluetooth or USB interface. 15 n Operating Condition: Temperature: 5~40;
Humidity: 80%. (Optimum use temperature:
23~28) n Measuring Condition:
Temperature: 15~30;
Humidity: 80% (Recommended). n Dimension:
130 mm 70 mm 29 mm (LWH). Weight: 190 g (No battery). Power Supply: Two AA alkaline batteries or 5 V 3 A. The adapter: Input: 100 V-240 V, 50/60Hz. Operating frequency: 2.402-2.480GHz. Maximum transmitting power: 4dBm Environment-Friendly Use Period: 4 years. 1.4.2 Performance of the printer Printer: Thermal line printer. Printer Paper: Thermal paper. Dimension:
110 mm 80 mm 38 mm (LWH). 16 n n n n n n n n n n n n n Weight: 180 g (without thermal paper). Operating Voltage: 5 V
. Power Supply: Printer: 5 V 3 A. The adapter: Input: 100 V-240 V, 50/60Hz. Power Consumption: 13.5 W. Environment-Friendly Use Period: 10 years. 1.5 Structure and Principle The instrument is basically composed of optical-electronic sensor system, mechanism and I/V converter, etc. Instrument structure as shown in figure 1.1. 17 Figure 1.1 The optical-electronic sensor system consists of a light source and a light receptor. The light from the light source falls on the reagent pads on the strip. The absorbance and reflectance vary with the color development of reagent pad, i.e. The degree of color development is proportional to the concentration of analyte in urine: if the color of reagent pad is darker, more light is absorbed and less light is reflected, vice versa. 18 The reflected light is transmitted into the Optical-electronic sensor system where the optical signals are transformed into electric signals. Then the electric signals are transformed by I/V convert then processed by CPU. Finally, test results are displayed on color display. 1.6 Appearance and Components Instrument (figure 1.2) Figure 1.2 19 Printer (figure 1.3) No. Items Function 1 USB interface voltage is 5 V DC. a. For charging. Charging b. For transmitting data. Displays operational 2 Display screen information, test results, Figure 1.3 etc. 20 4 Battery cover can be placed when 3 Key panel 5 6 7 8 9 Tray conveyor Strip tray Printer cover Printer USB interface The Printer indicator light Used for operating instruments. The first button on the left is the start key. Press 3 seconds to start the instrument. Two AA alkaline batteries turned on. Used to place the strip tray. strip. Used to place the reagent Open this cover to load a roll of printer paper. Connect the power. The green LED light on means that the printer is working. 21 Long press for 3 seconds to start-up. After start-up press this key into paper skip status. When turned on, long press for 3 seconds to shutdown. The printer will be re-start after you push down this key. 10 The printer power switch 11 The printer reset key 22 2. Installation 2.1 Action upon delivery Please check the instrument and accessories as below steps after receiving the carton:
1) Carefully unpack the shipping carton and take out the instrument and accessories. 2) Check the contents for quantity and visible signs of damage according to the accompanying Packing List. 3) Please notify your local distributor immediately if any damage or loss exists. 2.2 Instructions for use NOTE 1 It is the manufacturers responsibility to provide equipment electromagnetic compatibility information to the customer or user. NOTE 2 It is the users responsibility to ensure that a compatible electromagnetic environment for 23 the equipment can be maintained in order that the device will perform as intended. Caution self-testing:
1. Instructions for IVD medical equipment for a) Use of this instrument in a dry environment, especially if synthetic materials are present
(synthetic clothing, carpets etc.) may cause damaging electrostatic discharges that may cause erroneous results. b) Do not use this instrument in close proximity to sources of strong electromagnetic radiation, as these may interfere with the proper 2. Instructions for IVD medical equipment for operation. professional use:
a) The IVD medical equipment complies with the emission and immunity requirements of IEC 61326-1 and IEC 61326-2-6. 24 b) This equipment has been designed and tested to CISPR 11 Class A. In a domestic environment it may cause radio interference, in which case, you may need to take measures to mitigate the interference. c) The electromagnetic environment should be evaluated prior to operation of the device. d) Do not use this device in close proximity to sources of strong electromagnetic radiation
(e.g. unshielded intentional RF sources), as these can interfere with the proper operation. Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 25 operation. Caution NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 26 one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver
--Consult the dealer or an experienced radio/TV is connected. technician for help. CAUTION: To comply with the limits of the Class B digital device, pursuant to Part 15 of the FCC Rules, this device is to comply with Class B limits. All peripherals must be shielded and grounded. Operation with non-certified peripherals or non-shielded cables my result in interference to radio or reception. MODIFICATION: Any changes or modifications not expressly approved by the grantee of this device could void the users authority to operate the device. 27 Caution Hereby, URIT Medical Electronic Co., Ltd., declares that this UC-32A urine analyzer is in compliance with the essential requirements and other relevant provisions of RE Directive 2014/53/EU. A copy of the full DoC is attached. 2.3 Installing the battery Caution 1. When installing the battery, pay attention to the correct installation of the battery according to the battery polarity labeled in the battery bin 2. The instrument power supply is two AA of the instrument. alkaline batteries. 3. Remove the battery from the instrument 28 when the battery is used up or the instrument is not used for a long time. 4. Replace the waste batteries please in accordance with the relevant local laws and regulations properly handled. 1) Open the battery cover of the instrument. 2) Install two AA alkaline batteries in the instrument battery bin. 3) Cover the battery cover. 4) Press the start-up key to start the instrument, the instrument can start the work, indicating that the battery installation is correct. 2.4 Connect printer 1) Connect one end of the USB cable to the adapter (the adapter is connected to the power supply), one end to the USB interface of the printer, and one end to instrument, as shown in figure 2.1. The printer must be connected to power supply when in use. 2)Connect the instrument and printer via Bluetooth. 29 Figure 2.1 2.5 Loading Thermal Print Paper Printer cover Print paper storage area Paper exit Rubber roller Figure 2.2 1) Open the printer cover in the direction of upward, as shown in figure 2.2. 2) Use your fingers slight lift the printer rubber roller 30 toward your direction, and then upward remove the printer rubber roller. 3) Load the paper roll, put the printer rubber roller upward the printer clip, then use your fingers downward slightly push it into clip. 4) Please make the paper roll extends from the printer paper exit and put it into printing paper roll storage area, then closed the printer cover. Caution 1. Pay attention to the positive and negative of thermal printing paper. Print characters display only in the front of the paper roll, if installed backwards, the characters will not be printed. 2. Please leave enough length of print paper when install in order to make the paper roll extends from the print paper exit. 3. Please timely supply the print paper when it runs out. 4. Before load the print paper, please be sure to 31 check the print paper whether dry, if the print paper is moisture, then need to be changed in order to avoid the print paper jam. 5. Please reinstall if appears print paper jam situation. 32 3. Usage Precautions 3.1 Sample Usage Precautions 1) Be careful to take samples. Urine samples may carry pathogenic microbes that can cause infectious diseases. Take the utmost care when handling urine. Wear protective gloves to avoid exposure to urine samples. 2) Use fresh urine samples (Collect within one Samples must be measured within one hour, otherwise, keep them in refrigerator to avoid hour). deterioration. 3) Samples should be restored to the ambient temperature of the test Allow the refrigerated samples to return to the room temperature before testing, otherwise, the test results may be on the low side. Samples just collected should be returned to the room 33 temperature before testing, otherwise, the test results may be higher. 4) Mix each sample well before measurement. Do not centrifugal separation. If centrifugal separation is carried out, some components in the urine sample will precipitate, and some test items will not get accurate test 5) Sample volume should be enough to entirely soak all reagent pads on the strip. You cant do the normal test if there are no enough 6) Directly use the collected sample. Do not add preservative, disinfectant or detergent 7) Keep samples away from direct sunlight. Samples via direct sunlight goes bad and affect test 8) Sample containing Vitamin C can affect test results. samples. to samples. results. results. 34 When test the sample which contains Vitamin C may lead the occult blood and glucose readings may be lower than the actual value. 9) Drug-administered urine and visual hematuria can affect test results. Drug-administered urine and visual hematuria can affect test results and may not get the accurate test results. 3.2 Reagent Strips Usage Precautions 1) Please use the special reagent strips. Use only the URIT reagent strips and carefully read through the package inserts of the reagent strips. 2) Please confirm before use. Check the expiration date of reagent strips before use. Do not use the expired strips or strips that have discolored pads even if they are within the 3) Reagent strips should be prepared before the expiration date. test. Only take out the required number of reagent strips 35 from bottle before measuring samples, and cap the bottle immediately. Exposing the reagent strips to air for a long time will deteriorate the compositions of the reagent strips. strips. 4) Do not touch the reagent pads on the reagent Do not touch the reagent pads on the reagent strips. Doing so may affect test results. 5) Please keep desiccant. Do not discard the desiccant in the reagent strip bottle before using up all reagent strips. Otherwise the reagent strip may go bad because absorb the moisture in the air. 3.3 Instrument Usage Precautions 1) The instrument should be used on a clean, flat and stable horizontal platform and avoid direct sunlight, strong magnetic field interference and splash. 2) The instrument should avoid prolonged exposure to excessive humidity and high 36 temperatures. It should be used in a room of appropriate size, preferably air conditioning, temperature and humidity in accordance with the technical requirements of the instrument. To ensure the accuracy of the test results, please keep the temperature and humidity of workshop consistent with the environmental conditions required by the urine strip used. Caution The accuracy of the test results cannot be guaranteed if the instruments operating environment fails to meet the requirements of the urine reagent strip used. 3) The instrument should avoid being close to the sun, oven, heat source, radioactive source, etc., avoid excessive dust erosion, and avoid placing it on a vibrating table or refrigerator, and do not place the instrument in explosive air. 37 4) Observe the battery power of the instrument during use. Caution 1. If you continue to do the tests during the low power situation, in that case it cant guarantee the accuracy of the test results. 2. Please do not wait for the battery to run out of charge before charging, otherwise it will affect battery life. Please through observe the battery icon which in the instrument display screen to confirm the battery power. When the instrument indicates that the battery is low, please charge it in time. 38 4. The Instrument Use Procedures 4.1 Shut-down procedure 1) Turning on the power Keep pressing the Start key for 3 seconds to turn on the power. The instrument display screen lights up to display the welcome interface, the system self-test, the tray conveyor extends from the front of the instrument. The functions of each icon of the instrument are as follows:
Project 08:12:59 Function Display the system time of the instrument. Indicate that the instrument Bluetooth is connected to external devices. Indicate that the instrument is connected to an external power supply. Display the current status of battery. 39 Indicate that the item is in a state of waiting to be tested. Indicate that test results are normal. Indicate that the test results are not within the normal range. 2) Turning off the power Keep pressing the Start key for 3 seconds to turn off the power. The tray conveyor will retract inside the instrument and the display will be turned off. Caution The instrument will automatically turn off if it is inactive for five consecutive minutes. 4.2 Routine Measurement 4.2.1 Precautions Please read the following matters carefully and prepare samples to do the tests. 40 Biological risks 1. Put on protective gloves to avoid exposure to pathogenic microbes. 2. Dispose of used samples, reagent strips and gloves according to local regulations. Caution 1. The instrument should be placed on a level, stable and vibration-free worktable. 2. Do not touch the tray conveyor when it is moving. 3. Verify that the use environment is compliant with the requirements when testing. 4. Do not move or vibrate the instrument during measurement. Otherwise, erroneous test result will occur, or reagent strip may be blocked inside the instrument. 4.2.2 Preparing samples Please collect sufficient urine samples.:
41 Figure 4.1 Caution Caution The sample volume must be enough to soak all pads entirely on the reagent strip. Do not centrifugal separation, otherwise will cause haemocyte precipitation and make some items can't get accurate test results. 4.2.3 Preparing reagent strips Please refer to the package insert of reagent strips for specific information about how to handle reagent strips. 42 Caution Do not use the reagent strip that has exceeded the service life, or the reagent strip that has not expired but the reagent changes color, otherwise, the accurate test results cannot be obtained. 4.2.4 Measuring samples After you prepare the samples and reagent strips, please soaking the reagent strips with samples and then do the tests. The soaking time should use seconds as unit, so you should read the following steps completely to understand the operation steps. Caution To avoid hindering the movement of tray conveyor, leave at least 10 cm space to the front side of the instrument. 1) Verify that the instrument is in the main 43 interface and prepare the reagent strips and 2) Prepare some blotting papers at hand for Used for remove the excess samples from the samples for use. later use. reagent strips. Caution 3) Soak the reagent strip in the sample. 1. Be sure to make sure all the reagent strips are soaked in the sample. If the reagent block was not fully soaked, some of the items could not get the accurate test results. 2. The reagent strip should be soaked for approximately 2 seconds. If the immersion time is too short, the reagent strip can not be fully colored. On the contrary, too long time will cause the reagent component to flow out, thus the accurate detection results can not be obtained. 44 4) Remove the reagent strip from the sample, gently touch the edge of the reagent strip and suck out the excess urine. 5) Place the reagent strip on the strip tray. When placing, it is important to ensure that the reagent strip is fully placed in tray groove, and that the reagent strip has one side of the reagent block 6) Insert the strip tray into the tray conveyor of the instrument, and the instrument will test facing up. automatically. Note that the handle end of the reagent strip should be on the outside of the instrument, and make sure that the end of the strip tray touches the deepest slot of the tray conveyor. Caution 1. The handle end of the reagent strip should be guaranteed to be on the outside of the instrument. If the reagent strip is in the wrong direction, the instrument will prompt for error. 45 2. Be sure to place the strip tray on the tray conveyor correctly. Incorrect position of strip tray will affect the accuracy of test results. 7) Test result will be displayed after the strip tray re-move to the front of the instrument. The results will be transmitted to external devices via the Bluetooth interface if connected. 8) Take out the test tray. 4.2.5 When the measurement is completed 1) The used urine reagent strips, absorbent paper and other wastes should be discarded after detection.. 2) Clean the strip tray. Biological risks Dispose of the waste in accordance with the relevant local regulations. 46 5. Instrument Checkup 5.1 Checkup There are two check strips that come with the instrument. Use either one to check the performance of the instrument and compare the obtained results with the range printed on the check strip container. If the obtained results fall outside the range, use another check strip to repeat the test. If you continue to get out-of-range results, the instrument may not be working properly. Do not use the instrument. Please contact your local dealer. We suggest you do the checkup or quality control
(You can purchase the quality control material from URIT), if the following situations appear:
Use new urine reagent strip. Instrument replacing operators. Have doubt for the test results. 47 Caution 1. The check strip only used for daily check. 2. Please do not soak the check strip into any liquid. 3. Please keep the check strip clean. 4. Compare the obtained results with the range printed on the check strip container. If the obtained results inside the range that means the instrument can be normal use; if not please check the check strip is all right or not. 5. The range printed on the check strip container can only be used as the basis for judging instruments are in good condition, not as a reference for clinical diagnosis. 5.2 Checkup Operate 1) Insert the strip tray into the tray conveyor of the instrument. Note that the handle end of the reagent strip should be on the outside of the instrument, and make sure that the end of the strip tray touches 48 the deepest slot of the tray conveyor. Then the instrument will test automatically. Caution 1. The handle end of the reagent strip should be guaranteed to be on the outside of the instrument. If the reagent strip is in the wrong direction, the instrument will prompt for the error. 2. Be sure to place the reagent strip on the strip holder correctly. Incorrect position of reagent strip will affect the accuracy of test results. 2) Take back the check strip when the test finished. 49 6. Function Introduction 6.1 Function Introduction of Printer The instrument and printer can be connected to the Bluetooth interface. The will show in the instrument status bar when the instrument is open printer function and the printer has been successfully connected to the instrument. 6.2 Test Function Click the second button on the right at the main interface to select the range for automatic identification of reagent strip type. If testing 14TA reagent strip, please select [14TA], otherwise, please select [Auto]. Insert the strip tray into the tray conveyor at the main interface and the instrument will test automatically. After the instrument completes the test, the results will be displayed in semi-quantitative form and output. 50 Caution The result tested by the instrument can only be applied to screening some related diseases in the group according to the detection results of human urine. It cant be used directly as evidence for diagnosing diseases. 6.3 Introduction of Testing Result 1) The test results are as shown in figure 6.1. 3 1 2 Figure 6.1 51 No. Items Content Measurement 1 number 2 Test results The sequence number of the current sample test results. Test items and results.
(The system will display the corresponding test items based on the type of reagent strip detected.) The test results are represented by a semi-quantitative symbol.
(See Appendix for a comparison table between semi-quantitative symbols and concentration values.) The test item is preceded by
, which indicates that the result is within the normal range. 52 The test item is preceded by
, which indicates that the result is not within the normal range. The date and time of the current test results. 3 Date and Time 2) Output test result. A. The results will be transmitted to external devices via the Bluetooth interface if connected. B. If the instrument is successfully connected to the printer, the test results will be printed. C. Connect the computer through USB and export the test results to Lis software. 6.4 Reviewing Results Click the second button on the left at the main interface to enter the review interface. The review interface will display the instrument store test results. The function of each button is as follows:
53 Key Function Return to main Interface. View previous result. View the next result. For transmitting data. 6.5 Setting Please clickSettingkey under the standby screen into setting menu which has following functions:
1) QR code: Scan the QR code and connect to the mobile APP. 2) Unit: You can choose the unit is Char, SI, Conv, Char+Si or Char+Conv. 3) Ratio: ACR ratio is available. 4 Time: You can set the system time. 5 Bluetooth:You can choose the Bluetooth 54 connection mode is printer mode or phone mode. If you need to connect to the mobile APP, please switch to phone mode. If the printer mode is selected, press [Con] key will connect the printer and press
[Discon] key will disconnect the Bluetooth device. 6 Language: Sets the system language. 7 Delete Data: Clear all data. 8 Update firmware: After clicking this button, a dialog box appears on the screen, which displays connect USB cable to device and PC.Copy firmware,Press [Yes]. When firmware is copied to the instrument, press [Yes], and the instrument program will be automatically upgraded. 6.6 How to connect mobile APP 1) Mobile phone with Android system:
A. Turn on Bluetooth. Mobile phones with Android version 6 and above need to be authorized with WeChat location information, while mobile phones with Android version 10 and above need to turn on 55 the system switch of geographical location. B. Download WeChat APP --
register WeChat account -- Search "UC32" -- enter app interface. C. Click search or scan to search instrument or scan the QR code of urine analyzer setting interface to directly connect the instrument and app. D. Click "synchronize data" in app data center interface to synchronize data. 2) Mobile phone with iOS system:
A. Turn on Bluetooth. When the iPhone connects to the instrument for the first time, it is necessary to set the bluetooth access on WeChat APP. B. Download WeChat APP --
register WeChat account -- Search "UC32" -- enter app interface. C. Connect by searching the instrument name.. D. Click "synchronize data" in app data center interface to synchronize data. 56 6.7 Mobile APP introduction The mobile app is divided into three modules:
Device Management, Health Assessment and Data Center. As shown in figure 6.2. Figure 6.2 57 1) Device Management Manage the connected devices in the Device Management interface. 2) Health Assessment The latest comprehensive health assessment is displayed in the Health Assessment interface. 3) Data Center In the data center, you can synchronize all the test results data on the urine analyzer, and you can also switch the account number. 58 7. Maintenance 7.1 Precautions Biological risks 1. To avoid exposure to pathogenic microbes, put on protective gloves during maintenance. 2. Dispose of used reagent strips, fabric, and protective gloves according to local regulations. 7.2 General cleaning Keep the instrument clean and dust-free. If cleaning is needed, clean the instrument surface with clean paper or gauze dipped with medical alcohol.. Any oil, ester, silica gel and lubricant are not advisable for use on the instrument. 7.3 Cleaning the strip tray (Daily) During measurements, urine may adhere to the 59 strip tray which will contaminate the reagent strip. So, it is necessary to wash the strip tray each day when all measurements are completed. 1Turn on the power and wait for self-check of the 2) Please remove the strip tray from the tray instrument. conveyor. 3Clean the strip tray. Clean the strip tray by using mild detergent, and wash the adhered urine off with running water. Use soft fabric to dry the strip tray. 4Put the strip tray on the tray conveyor. 60 8. Storage and Handling UC-32A is a precise instrument. Transport it with utmost care and avoid moisture, sunlight and Transportation Condition:-20~55, RH 95%, 8.1 Handling collision. 75 kPa~106 kPa 8.2 Storage The packed instrument should be stored in a ventilated room. Do not store the instrument with toxicant, injurant and corrosive. Storage Condition: -20~55, RH 95%, 75 kPa~106 kPa 61 9. Troubleshooting Fault message will display on the display if there is something wrong with the instrument. Please refer to the following. If you still can not resolve the problem, please contact your dealers or after-sales service unit immediately. Caution 1. If an fault message appears, clear the error and retest the sample using a new reagent strip. Correct results may not be yielded if the soaking-time of reagent strip is too long. 2. Any serious adverse event involving the device shall be reported to the manufacturer and the competent authority of the member country where the user or patient is located. 62 Troubleshooting Table Trouble Possible Handling Method Code Cause T-1 T-2 T-3 Test Sensor instrument. If still Error unable to resolve, Please check to see if the strip tray is falling off. Restart the please contact the after-sales service unit. Strip Motor Check if the strip tray Error is installed correctly. Strip Type Error T-4 No strip Please confirm that you are using the URIT brand HC series urine reagent strip. Place a reagent strip on the strip tray. 63 64 Appendix The instrument test results and the density contrast compare table 65
1 | label and location | ID Label/Location Info | 1.35 MiB | January 20 2022 / January 24 2022 |
RIT ay HN 48mm FCC statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and
(2)This device must accept any interference received, including interference that may cause undesired operation. 36mm Importer:
1 | Authorisation letter | Cover Letter(s) | 173.23 KiB | January 20 2022 / January 24 2022 |
Company name:URIT Medical Electronic Co., Ltd. Address:No.D-07 Information Industry District, High-Tech Zone, Guilin, Guangxi 541004, P.R.China Date (2021-06-09) TUV SUD BABT UNLIMITED Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Dear Sir or Madam, We, URIT Medical Electronic Co., Ltd. Address:No.D-07 Information Industry District, High-Tech Zone, Guilin, Guangxi 541004, P.R.China, hereby authorize Kevin Ouyang TUV SUD China Senior Project Engineer / EMC Department 5F, Communication Building, 163 Pingyun Rd, Huangpu Ave. West Guangzhou, P.R.China 020-38170584) to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Models: UC-32A, UC-32B, UC-32A Vet, UC-32B Vet FCC ID: 2AZS3UYUC32AB This authorization period is for one year. Sincerely, Company Officer:Ma dejia Ma dejin Telephone Number:+86 18877380717 Email: abc1085@163.com
1 | Confidentiality request | Cover Letter(s) | 242.12 KiB | January 20 2022 / January 24 2022 |
Company name:URIT Medical Electronic Co., Ltd. Address:No.D-07 Information Industry District, High-Tech Zone, Guilin, Guangxi 541004, P.R.China Date (2021-06-09) TUV SUD BABT UNLIMITED Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom Confidentiality Request Models: UC-32A, UC-32B, UC-32A Vet, UC-32B Vet FCC ID: 2AZS3UYUC32AB Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission's Rules, URIT Medical Electronic Co., Ltd. Adaress:No.D-07 Information Industry District, High-Tech Zone, Guilin, Guangxi 541004, P.R.China, hereby requests permanent confidential treatment of information accompanying this application as outlined below:
Schematics Bill of Materials/Parts List Block Diagrams Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer:Ma dejia M a dejia Telephone Number:+86 18877380717 Email:abc1085@163.com
1 | Model similarity | Cover Letter(s) | 179.92 KiB | January 20 2022 / January 24 2022 |
Company name:URIT Medical Electronic Co., Ltd. Address:No.D-07 Information Industry District, High-Tech Zone, Guilin, Guangxi 541004, P.R.China Seem Model difference declaration Date (2021-06-09) TUV SUD BABT UNLIMITED Octagon House, Segensworth North, Fareham, Hampshire, PO15 5RL, United Kingdom We,
(URIT Medical Electronic Co., Ltd. Address:No.D-07 Information Industry District, High-
PR.China), Tech Zone, Guilin, Guangxi 541004, Here declare Product: Urine analyzer Model: UC-32A, UC-32B, UC-32A Vet, UC-32B Vet FCC ID: 2AZS3UYUC32AB The two models UC-32A, UC-32A Vet are identical in circuit design, PCB layout and components used but only different in model name. The two models UC-32B, UC-32B Vet are identical in circuit design, PCB layout and components used but only different in model name. The two models UC-32A, UC-32B are identical in circuit design, PCB layout but different in model name and components used. All models used same Bluetooth module. The difference between UC-32A and UC-32B in PCBA is that UC-32B has lithium battery charging management circuit and soft reset circuit, while UC-32A does not. In addition, UC-32A uses entity keys and UC-32B uses touch keys. Sincerely, Company Officer:Ma dejia Ma dojia. Telephone Number:+86 18877380717 Email:abc1085@163.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-01-24 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-01-24
|
||||
1 | Applicant's complete, legal business name |
URIT Medical Electronic Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0030869630
|
||||
1 | Physical Address |
No.D-07 Information Industry District
|
||||
1 |
GuiLin Guangxi, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@tuv-sud.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AZS3
|
||||
1 | Equipment Product Code |
UYUC32AB
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M**** d****
|
||||
1 | Telephone Number |
+8618********
|
||||
1 | Fax Number |
+86 7********
|
||||
1 |
a******@163.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Urine analyzer with Bluetooth function | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power is conducted. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV SUD Cert & Testing (China) Co., Ltd.
|
||||
1 | Name |
H******** Z****
|
||||
1 | Telephone Number |
86 75********
|
||||
1 |
h******@tuv-sud.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0011600 |