STD COP caster Specication Applicant Manufacturer
:
:
Zhuhai Rocateq Technology Company Ltd D,3rd Floor 1# Factory 8,Chuang Xin Liu Road,Xiangzhou District,Zhuhai,Guangdong,519085,P.R.China Zhuhai Rocateq Technology Company Ltd D,3rd Floor 1# Factory 8,Chuang Xin Liu Road,Xiangzhou District,Zhuhai,Guangdong,519085,P.R.China
: Rocateq
: Caster STD&OCS COP
: Caster STD COP, Caster OCS COP Trade Mark EUT M/N FCC Statement:
This equipment has been tested and f ound to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasona ble protection against harmful interference in a residential installation. This equipment generates, uses an d can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that inte rference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be dete rmined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet which the receiver is connected. Consult the dealer or an experien ced radio/TV technician for help. This device complies with part 15 of th e FCC Rules. Operation is subject to the following two conditions: (1) Th interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modi f cations to this device not explicitly approved by manufacturer could void your authority to operate this equipment. on a circuit different from that to is device may not cause harmful 1 1 Subject Matter and Scope This standard species the Rocateq COP shopping caster production, technical requirements, test methods, inspection rules, marking, packaging and storage. 2 Reference Standard ANSI / ASQ Z1.4-2003 each inspection Sampling and sample forms (for continuous batch of checks) GB / T 14688-93 industrial casters 3 Term, Code 31 Casters Having a wheel mounted on the eccentr icity of the stent, the stent can be rotated around the geometrical axis vertical line (see FIG. 1) 2 32 Screw Casters Mounting structure for the casters of the screw (see Figure 1) The distance between c asters steerin g axis and the axes of rotation of the wheels (see 33 Eccentric distance E Figure 1) 34 Brackets The part for install the wheel and can be rotated in the meantime. 4 Main dimensions and loading capacity d 1 D H E L Fig 2 loading capacity W (Kg) mm 38.5 M12 65 152 125 Table 3 32 5 Technical conditions 5.1 Appearance Quality All Metal parts of the surface should use effective methods to prevent corrosion. All the parts should not affect the use. 5.2 Assembly quality 5.2.1 All rotating parts (wheels, brackets) should be exible rotation, no jams, abno rmal noise or inattentive. 5.2.2 Wheel and tire assembly rm, does not rotate with the wheel axle. 5.2.3 Reliable performance brakes. 3 NO
. 1 2 3 4 5 6 7 5.3 Main dimensions casters in accordance with Table 3. 5.4 Electrical parameters ITEM Parameters Normal temperature Voltage 3V 10%
Environmental Testing
-2060 3V 10%
5%
50%
50%
20%
10%
150mA 50uA when locked locked 30uA 150mA Standby current Locked operation current Unlcoked operation current Current receiving signal at state Distance receiving MRU Receiving frequency Emitter Frequency 317.95MHZ~318.15MHZ Emitter distance Emitter Power 8.13KHZ 25cm by
>10m(open)
>- 50dB 8 9 10 Test conditions 5.4.1 Environmental temperature -20~60, 5.4.2 Voltage3V 10%;
5.4.3 Accessories: MRU, EET, COT, COP Alarm 5.4.4 Test Methods A: Lock & Unlock function test:
1. Power: Connect a 3V battery, the motor is rotating until it detects the switch, the motor stops. 2. Lock: At the unlocked state, the lock signal is received, the motor rotates, locking the wheel, the wheel lock time is less than 3 seconds. 3. Unlock: At the locked state, received unlock signal, the motor rotates, unlocking the wheel, the wheel unlock time is less than 3 seconds. 4. When locked, the steady current motor 150mA 5. When unlocked, the steady current of motor 150mA B: Wheel PUSH OUT system function test:
B-1. At unlocked state, receive entrance signal emitted entrance (into the supermarket). a. within 30S, the wheel doesn't receive checkout signal (not across the cashier), and then receives entrance signal. The wheels will not lock, nor drive alarm. the wheel returns to the initial state. 4 b. after 30S, the wheel doesn't receive checkout signal (not across the cashier
), and then receives entrance signal. The wheel will lock, drive alarm. the wheel goes to the Locked state c. the wheel receives checkout signal (across the cashier), and then receives entrance signal. The wheels will not lock, nor drive alarm. the wheel returns to the initial state. B-2 wheel locked state. If the w heel is locked outside the supermarket control to unlock the wheels return to the initial state.
, by Unlock button on the remote 5.5 waterproof test The ba ttery compartment and the controller into the water 30 minutes, the water depth 20cm, conrm that the battery box and the controller does not have water in it. 5.6 running performance Under the test conditions specied in 6.1, on a test machine runni ng 30,000 times across the obstacle, should meet the following requirements:
a. tire without cracking, spalling and excessive wear;
b. casters has no normal damage or affect the use of permanent deformation;
c. Bearing normal rotation, free of loose and jam. 5.7 tire wear In the case of the wheel lock, the implementation of 100M, reduce the amount of wheel diameter of 2.0 mm 5.8 braking performance When the wheels lock, single damper rotational torque 22kgf.cm ~ 35kgf.cm. 5.9 salt spray test Dependent on manufacturers testing. 6. Test Method 6.1 Test conditions 6.1.1 Ambient temperature 20 10 , bearing 65kg 6.1.2 Table: horizontal, rigid 6.1.3 Walking obstacles. Single 6.2 waterproof test The battery compartment and the controller into the water (water depth 20cm), 30 minutes standing time, conrm that the battery box and the controller does not water 6.3 running performance test Under the test conditions specied in 6.1, on a test machine running across obstacles 30,000 times 6.4 braking performance test Press the LOCK button on the remote control wheels are locked, face control box, the wheel can be rotated in a clockwise direction, the inverse Clockwise difcult. Test each damper rotational torque, the torque requirement 22kgf.cm F 35kgf.cm, use self-test system tools. 6.5 tire wear test 5 Wheel locked state implemented in the cement pavement 100 meters, the wheel diameter reduction amount 2.0mm 7. Inspection Rules 7.1.1 factory inspection content see 5.1-5.4 7.1.2 factory inspection batch inspection according to the provisions of ANSI /
ASQZ1.4-2003 . 7.2 Type inspection 7.2.1 casters have one of the following conditions, type inspection should be carried out:
a .new products or old products to the plant trial stereotypes identication;
b. product design, process, material signicant changes;
c. shut down and restarted when more than eight months;
d. normal continuous production of products, once a year.;
e. State Administration of Quality Supervision bodies type inspection requirements. Content 7.2.2 Type inspection see 5.5-5.9 bar. 7.2.3 Type test in any one of the caster any project failed, we should redouble the same batch of product sampling, review of the project failed. Recheck qualied, this batch of qualied products, if any re-examination of when a project failed, the batch of product failure. Substandard products, improved or repaired after resubmit the test. 7.3 Acceptance Ordering party according to the factory acceptance test items of products, such as the quality of dispute occurred, both supply and demand of the product supply agreement review. 8. Logo, packaging and storage 8.1 ag, the ag should include trademark 8.2 Packaging Each factory should be properly packed casters 8.3 Storage Casters (including b oxed caster) shall be in a well -ventilated, relative humidity less than 80%, non-corrosive gases stored in the warehouse, storage period of 12 months. 6