app
s
|
Applicant Information
|
|
various
|
Effective |
2024-01-02
|
various
|
2023-12-28
|
various
|
2023-03-10
|
various
|
2023-02-23
|
various
|
2022-12-29
|
various
|
2022-03-04
|
various
|
2022-01-11
|
various
|
Applicant's complete, legal business name |
HP Inc.
|
various
|
FCC Registration Number (FRN) |
0025126541
|
various
|
0008035131
|
various
|
Physical Address |
3390 East Harmony Road
|
various
|
Fort Collins, CO
|
various
|
Fort Collins, Colorado 80528
|
various
|
United States
|
|
app
s
|
TCB Information
|
various
|
TCB Application Email Address |
K******@sporton-usa.com
|
various
|
t******@timcoengr.com
|
various
|
c******@telefication.com
|
various
|
TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
|
app
s
|
FCC ID
|
various
|
Grantee Code |
B94
|
various
|
Equipment Product Code |
MT7922A22MB
|
|
app
s
|
Person at the applicant's address to receive grant or for contact
|
various
|
Name |
R******** P******** T********
|
various
|
Title |
US Canada Technical Regulations
|
various
|
Telephone Number |
970-8********
|
various
|
Fax Number |
000-0********
|
various
|
E-mail |
r******@hp.com
|
|
app
s
|
Technical Contact
|
various
|
Firm Name |
Bureau Veritas Consumer Products Services (H.K.)
|
various
|
Name |
K******** L********
|
various
|
Physical Address |
E-2,no.1,Li Hsin 1st Road, Hsinchu Science Park
|
various
|
Taiwan
|
various
|
Telephone Number |
+8863********
|
various
|
Fax Number |
88633********
|
various
|
E-mail |
k******@bureauveritas.com
|
|
app
s
|
Non Technical Contact
|
various
|
Firm Name |
Bureau Veritas Consumer Products Services (H.K.)
|
various
|
Name |
A**** W******
|
various
|
Physical Address |
No. 70, Wenming Rd., Guishan Dist., Taoyuan City
|
various
|
Taiwan
|
various
|
Telephone Number |
+8863********
|
various
|
E-mail |
a******@bureauveritas.com
|
|
app
s
|
Confidentiality (long or short term)
|
various |
Does this application include a request for confidentiality for any portion(s) of the data
contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes |
various | Long-Term Confidentiality
Does this application include a request for confidentiality for any portion(s) of the data
contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes |
various | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 06/30/2024 |
various | 06/26/2024 |
various | 09/06/2023 |
various | 08/01/2023 |
various | 06/27/2023 |
various | 08/31/2022 |
various | 07/10/2022 |
|
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
|
|
|
app
s
|
Cognitive Radio & Software Defined Radio, Class, etc
|
various |
Is this application for software defined/cognitive radio authorization? | No |
various | Equipment Class | NII - Unlicensed National Information Infrastructure TX |
various | 6XD - 15E 6 GHz Low Power Indoor Client |
various | DTS - Digital Transmission System |
various | DSS - Part 15 Spread Spectrum Transmitter |
various | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 2TX 11ax (WiFi6E) BW160 + BT/BLE Combo Card |
various | 2TX 11ax (WIFI6E) BW160+BT/BLE Combo Card |
various | 2TX 11ax (WiFi6E) BW160+BT/BLE Combo Card |
various | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | Yes |
various | No |
various | Modular Equipment Type | Does not apply |
various | Single Modular Approval |
various | Purpose / Application is for | Class II Permissive Change |
various | Class II permissive change or modification of presently authorized equipment |
various | Change in Identification |
various | Composite Equipment: Is the equipment in this application a composite device subject to an
additional equipment authorization? | Yes |
various | Related Equipment: Is the equipment in this application part of a system
that operates with, or is marketed with, another device that requires an equipment authorization? | No |
various | Grant Comments | Output power listed is conducted, except for U-NII 4 which is EIRP. Single Modular Approval for portable/mobile configurations. SAR has been evaluated at 5 mm. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators, or end-users if marketed directly to end-users, with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, 40, 80 and 160 MHz modes.
Class II Permissive Change: Enables U-NII Band 4 via software update.
Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C173. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.44 W/kg and 0.55 W/kg, respectively. |
various | Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.
Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C173. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.33 W/kg and 0.63 W/kg, respectively. |
various | Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C173. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.31 W/kg and 0.31 W/kg, respectively.
C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. |
various | Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C173. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.11 W/kg and 0.63 W/kg, respectively.
C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. |
various | Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.
Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C175. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.40 W/kg and 0.78 W/kg, respectively. |
various | Output power listed is conducted, except for U-NII 4 which is EIRP. Single Modular Approval for portable/mobile configurations. SAR has been evaluated at 5 mm. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators, or end-users if marketed directly to end-users, with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, 40, 80 and 160 MHz modes.
Class II Permissive Change: Enables U-NII Band 4 via software update.
Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C175. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.47 W/kg and 0.56 W/kg, respectively. |
various | Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C175. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.38 W/kg and 0.38 W/kg, respectively.
C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. |
various | Class II Permissive Change: Enables portable use when integrated into the HP Convertible PC, TPN-C175. The highest reported SAR for body and simultaneous transmission exposure conditions are 0.10 W/kg and 0.78 W/kg, respectively.
C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. |
various | Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.
RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 0.68 W/kg, respectively.
Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C166. The highest reported SAR use on the body, simultaneous transmission and power density exposure conditions are 0.27 W/kg, 0.64 W/kg and 6.60 W/m2, respectively. |
various | Output power listed is conducted, except for U-NII 4 which is EIRP. Single Modular Approval for portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.03 W/kg, respectively. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators, or end-users if marketed directly to end-users, with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, 40, 80 and 160 MHz modes.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C166. The highest reported SAR use on the body, simultaneous transmission and power density exposure conditions are 0.96 W/kg and 1.44 W/kg, respectively. |
various | This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.65 W/kg and 0.74 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.29 W/kg and 0.55 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.77 W/kg, respectively.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C166. The highest reported SAR use on the body and simultaneous transmission exposure conditions are 0.62 W/kg and 1.31 W/kg, respectively. |
various | This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 1.03 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 0.60 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.43 W/kg and 1.19 W/kg, respectively.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C166. The highest reported SAR use on the body and simultaneous transmission exposure conditions are 0.19 W/kg and 1.31 W/kg, respectively. |
various | C2PC: Adding a portable host: Notebook Computer (Brand: HP, Model: HSN-I54C).
The SAR data in this filing is applicable to demonstrate compliance for body operating condition and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm.
The highest reported SAR value for body condition and simultaneous transmission use conditions are 0.48 W/kg and 0.48 W/kg.
C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.65 W/kg and 0.74 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.29 W/kg and 0.55 W/kg, respectively. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.77 W/kg, respectively. |
various | C2PC: Adding a portable host: Notebook Computer (Brand: HP, Model: HSN-I54C). The SAR data in this filing is applicable to demonstrate compliance for body operating condition and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. The highest reported SAR value for body condition and simultaneous transmission use conditions are <0.10 W/kg and 0.13 W/kg.
Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 0.68 W/kg, respectively. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths. |
various | C2PC: Adding a portable host: Notebook Computer (Brand: HP, Model: HSN-I54C).
The SAR data in this filing is applicable to demonstrate compliance for body operating condition and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm.
The highest reported SAR value for body condition and simultaneous transmission use conditions are 0.82 W/kg and 0.94 W/kg.
Output power listed is conducted, except for U-NII 4 which is EIRP. Single Modular Approval for portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.03 W/kg, respectively. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators, or end-users if marketed directly to end-users, with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, 40, 80 and 160 MHz modes.
Class II Permissive Change: Enables U-NII Band 4 via software update. |
various | C2PC: Adding a portable host: Notebook Computer (Brand: HP, Model: HSN-I54C).
The SAR data in this filing is applicable to demonstrate compliance for body operating condition and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm.
The highest reported SAR value for body condition and simultaneous transmission use conditions are 0.12 W/kg and 0.94 W/kg.
C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 1.03 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 0.60 W/kg, respectively. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.43 W/kg and 1.19 W/kg, respectively. |
various | Output power listed is conducted, except for U-NII 4 which is EIRP. Single Modular Approval for portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.03 W/kg, respectively. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators, or end-users if marketed directly to end-users, with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, 40, 80 and 160 MHz modes.
Class II Permissive Change: Enables U-NII Band 4 via software update. |
various | This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.03 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.60 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.19 W/kg, respectively.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C158. The highest reported SAR for use at the body and simultaneous transmission exposure conditions are 0.69 W/kg and 1.43 W/kg, respectively. |
various | This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.65 W/kg and 0.74 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.29 W/kg and 0.55 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.77 W/kg, respectively.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C158. The highest reported SAR for use at the body and simultaneous transmission exposure conditions are 0.54 W/kg and 1.09 W/kg, respectively. |
various | Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.
RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 0.68 W/kg, respectively.
Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C158. The highest reported SAR use on the body and simultaneous transmission exposure conditions are 0.13 W/kg and 0.43 W/kg, respectively |
various | This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 1.03 W/kg, respectively. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 0.60 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.43 W/kg and 1.19 W/kg, respectively.
Class II Permissive Change: Enables portable operation when integrated into the HP portable computer, model TPN-C158. The highest reported SAR for use at the body and simultaneous transmission exposure conditions are 0.19 W/kg and 1.43 W/kg, respectively. |
various | Output power listed is conducted. This module is approved in portable/mobile configurations with Antennas as described in the filling. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.
RF exposure compliance. Power Density and SAR testing was performed to demonstrate RF exposure compliance. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 0.68 W/kg, respectively.
Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. Device operation is intended for indoor use only. This device has 20/40/80/160 MHz bandwidths. |
various | C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.77 W/kg and 1.03 W/kg, respectively.
Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80/160 MHz bandwidths.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.60 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.76 W/kg and 1.19 W/kg, respectively. |
various | C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.65 W/kg and 0.74 W/kg, respectively.
Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidths.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.29 W/kg and 0.55 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.34 W/kg and 0.77 W/kg, respectively. |
various | C2PC : Adding the dipole antennas as described in the filling and updating WiFi 6E band. This module is approved in portable/mobile configurations. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 1.03 W/kg, respectively.
Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 5 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.26 W/kg and 0.60 W/kg, respectively.
The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 8 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.43 W/kg and 1.19 W/kg, respectively. |
various | Is there an equipment authorization waiver associated with this application? | No |
various | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No |
|
app
s
|
Test Firm Name and Contact Information
|
various
|
Firm Name |
SPORTON International Inc.
|
various
|
SGS Taiwan Ltd. Central RF Lab
|
various
|
Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch
|
various
|
Name |
A****** C********
|
various
|
R******** W********
|
various
|
E**** L******
|
various
|
Telephone Number |
+886-******** Extension:
|
various
|
+886-******** Extension:
|
various
|
+886-********
|
various
|
Fax Number |
+886-********
|
various
|
+886-********
|
various
|
+886-********
|
various
|
E-mail |
a******@sporton.com.tw
|
various
|
r******@sgs.com
|
various
|
e******@bureauveritas.com
|
|