submitted | available | document details (if available) | source link |
---|---|---|---|
December 02 2013 | December 02 2013 | untitled Brad Marshall Adobe PDF Library 10.0 |
various | Uses Manual | Users Manual | 145.36 KiB | December 02 2013 |
TK/TKD/TKQ Quick Start Getting to Know Your TK/TKD/TKQ Tracking System TK Controls Overview Select/Log: Press to take a depth and log the locate point. Down Arrow: Press to scroll down in menu. Also use to decrement values in settings. Up Arrow: Press to scroll up in menu. Also use to increment values in settings. Menu/On/OFF: Press to enter and exit menus. Press once to turn unit on. Press and hold to turn unit off. Screen Item Descriptions 1. Signal Strength: Signal strength is shown by bars at top of display and in numeric display. 2. Roll Position: Roll angle graphically by pointer on numerically by the time. 3. Pitch: Direction and amount of pitch up and down displayed in the units selected in the set up. 4. Depth: Displays the distance from the tracker to the beacon. This value is displayed in the units selected in the set up. is displayed the clock and 5. Tracker Battery Status: Indicates the level of the batteries currently installed in the tracker. 6. Time: Displays current time in 24 hour clock format. 7. Telemetry Radio: Tower indicates radio is on and numeric value indicates the channel. 8. Bluetooth Status: Indicates that Bluetooth is enabled and is currently in use with another device. 9. Beacon Battery Status/Beacon Type: Indicates the status of the battery level in the beacon. Text below indicates the type of beacon currently set in the tracker. 10. Communication Quality Graph: Indicates the quality of signal required for good communication. Full graph indicates excellent signal quality, while one bar indicates poor quality as it relates to communication. 11. Beacon Temperature: Indicates the status of the temperature graphically and numerically according to the units setting in the menu. 12. Bubble Level: Indicates the plumb and level of the tracker. The more level the unit the more accurate the depth measurement. 13. Gain Status: This bar indicates the amount of gain set in the tracker to get the signal currently displayed. TK Menus Press the Menu key to enter menus. Scroll through menu selections with arrow keys. Press Menu key again to go back to previous menu or exit menus mode. Drill-To/Walkover: Toggles unit between walkover and drill-to modes. Beacon: Handles beacon calibration, frequency settings, roll and pitch calibration, beacon information, and the bore-path analyzer. Wireless: Handles the settings for telemetry radio, channel settings, Bluetooth, tracker control, and tracker control codes. Settings: Set up for language, units, backlight, clock, volume, and auto-power settings. Logging: Settings for auto-log, creating new log, log manager, deletion of logs, and deletion of last pipe. System: Access to functions such as information about the tracker, diagnostics and software updates. Startup Tips Installing The Batteries TK/TKD/TKQ Use four C-cell alkaline or NiMH batteries in tracker. To install 1. Remove battery caps. 2. Remove batteries. 3. Insert batteries as shown. 4. Install battery caps. 5. Check operation. The unit will not come on if a battery is installed backwards. FCCID: ITQ-TK IC: 3598A-TK IMPORTANT: See Operators Manual for detailed safety and operating instructions. P/N 790-XXXXA TK/TKD/TKQ Quick Start Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourraient annuler l'autorit de l'utilisateur utiliser cet quipement. RF Exposure Statement In order to comply with RF exposure requirements during normal operation, this device must be held in front of the body horizontally. The antenna must be vertical in line with the body with at least 8 (20 cm) separation distance from the body. This equipment has been tested for RF exposure according to FCC rules for body-worn equipment. The equipment must be operated in accordance with manufacturer expectations to insure RF exposure compliance. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Information can be obtained at http://www.hc-sc.gc.ca/ewh-sem/pubs/radiation/radio_guide-lignes_direct-eng.php Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme d installation de cet appareil doit s assurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Les informations peuvent tre obtenues:
http://www.hc-sc.gc.ca/ewhsemt/pubs/radiation/radio_ guide-lignes_direct-eng.php FCCID: ITQ-TK IC: 3598A-TK IMPORTANT: See Operators Manual for detailed safety and operating instructions. P/N 790-XXXXA
This product uses the FCC Data API but is not endorsed or certified by the FCC