submitted | available | document details (if available) | source link |
---|---|---|---|
January 10 2019 | April 10 2019 |
various | User Manual | Users Manual | 1.17 MiB | January 10 2019 / April 10 2019 |
IDENTEC SOLUTIONS i-B350L -CC HARDWARE USER MANUAL i-B350L -CC Hardware User Manual | 20. September 2019 Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without the prior written authorization from IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, suitability for a particular purpose and accuracy. IDENTEC SOLUTIONS shall not under any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks IDENTEC SOLUTIONS, Intelligent Long Range, ILR and the stylized i are registered trademarks. i-PORT and Visibility Delivered. are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS. Issue 3.0 / September 2019 (MOM) Subject to alteration without prior notice. Copyright 2019 IDENTEC SOLUTIONS AG Printed in Austria Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 2 i-B350L -CC Hardware User Manual | 20. September 2019 Radio Frequency Compliance Statement IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices:
MODEL:
Region/Country Organization EUROPE:
USA:
CANADA:
EU FCC Industry Canada i-B350L CC Marking CE FCC ID: OO4-ILR-IB350LCC 3538A-IB350LS The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or unauthorized changes to approved products, may void the compliance of these products and result in the loss of the user(s) authority to operate the equipment. European Notification According R&TTE Directive This equipment complies to Art. 6.4 of R&TTE Directive (2014/35/EU, 2014/30/EU, 99/5/EC [expires on June, 12th 2016] and 2014/53/EU [valid from June, 13th 2016]). It is tested for compliance with the following standards: EN 300 220-1, ETSI EN 300 220-2, ETSI EN 301 489-1, ETSI EN 301 489-3, EN 60950-1:2006 + A11:2009 + A1:2010 +
A12:2011 USA Notification This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION TO USERS Changes or modifications not expressly approved by the party responsible for compliance could void the user`s authority to operate the equipment. Class B: (Section 15.105) FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/ TV technician for help. (Section 15.21) CAUTION: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. Canada Certification This device complies with Industry Canadas license exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 3 i-B350L -CC Hardware User Manual | 20. September 2019 WARNING - This product should be installed by personnel trained in installation of equipment in industrial environments and meet the representative countrys National Electrical Code. Electrostatic Discharge This product contains components that are sensitive to electrostatic discharges. Please observe the special instructions for their protection. Incorrect handling can damage the unit and cause the invalidation of the warranty. Minimum safety precautions against electrostatic discharge:
Establish earth contact before you touch the unit. (For example, touch the earthing screw on the unit.) Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit. Avoid unnecessary contact with the unit connectors and assemblies inside the unit. Only open the unit if the operational settings (as described in the manual) expressly requires it. Use antistatic tools for the setting of the unit. (Warning: Do not touch life-threatening voltages with these tools). Do not store unit and components without protective packaging. Remove unit and components from the packaging only prior to installation. These notes are not sufficient to guarantee complete protection from electrostatic discharges! We recommend the use of suitable protective equipment. IDENTEC SOLUTIONS does not accept the return of products where the regulations concerning the ESD precautions and protective packaging materials were not followed. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 4 i-B350L -CC Hardware User Manual | 20. September 2019 Safety Instructions The system described in this manual is for exclusive operation of trained employees. Only qualified personnel that have knowledge of the potential dangers involved should perform the installation, settings, maintenance and repair of the units used. Operational Safety The correct and safe use of these systems assumes that operating and service personnel follow the safety measures described in the manual alongside the generally acceptable safety procedures. If there is a possibility that safe operations cannot be guaranteed, the system must be switched off, secured against accidental use and the service unit responsible immediately informed. Safety Documents The i-B350L CC was designed, tested and supplied in perfect condition according to document IEC/EN 60950-1 Safety Requirements. Condensate / Change of Temperature To avoid condensation in the system, the unit must be allowed to slowly adjust itself to warmer temperatures after removal from cold and cool environments. Connections / Power Supply The supply circuits must comply with the conditions set out for the SELV circuits (see EN 60950-1). During maintenance damage could occur if printed circuit boards or cables are connected or disconnected whilst the power supply is still on. Therefore, only work on the connection and the components when they are not live. Battery Inside All system tags contain a battery; therefore, the following warning should be heeded:
WARNING - Fire, explosion and burn hazard risk of explosion if battery is replaced by an incorrect type. Do not recharge, short circuit, crush, disassemble, heat above 100 C (212 F). Do not incinerate, or expose contents to water Spare Parts We recommend that only personnel, original products, spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation, service and repair. IDENTEC SOLUTIONS does not accept any responsibility for materials used, work carried out or possible consequences from unauthorized third party vendors. Glossary SELV Safety Extra Low Voltage Protective measure against dangerous body currents. Protective first voltage, circuit not floating. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 5 i-B350L -CC Hardware User Manual | 20. September 2019 Contents 1. Preface .................................................................................................................................................................... 7 2. Introduction .............................................................................................................................................................. 8 2.1 General Information ......................................................................................................................................... 8 2.2 System Components Tags............................................................................................................................ 8 2.3 System Components Readers .................................................................................................................... 9 2.4 System ComponentsAntennas ................................................................................................................... 10 3. Configuration of the Tag ........................................................................................................................................ 11 3.1 General .......................................................................................................................................................... 11 3.2 Ping Rate ....................................................................................................................................................... 11 3.3 Bursts when passing a Position marker ......................................................................................................... 12 3.4 Limitations of the User Data Field .................................................................................................................. 12 3.5 Information of Burst Settling ........................................................................................................................... 12 4. Troubleshooting ..................................................................................................................................................... 14 5. Maintenance .......................................................................................................................................................... 14 5.1 Returns ........................................................................................................................................................... 14 6. Technical Specifications ........................................................................................................................................ 15 Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 6 i-B350L -CC Hardware User Manual | 20. September 2019 1. Preface This installation manual must be read carefully prior to starting the installation. The described installation works assuming that installation materials like cables, antennas and any mechanical parts are available. This document is the hardware description of the i-B350L CC. This document is intended only for mechanical and electrical installation of these central units. IDENTEC SOLUTIONS reserves the right to make changes and updates to the content contained herein. It is the users responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures. Updates will be provided upon request. The information in this document may be subjected to changes without prior notice. Check whether delivery is complete and for any damages. If the delivery is not complete or damaged immediately inform the carrier. The dispatch and service organization of IDENTEC SOLUTIONS should also be informed to facilitate the repair or exchange of the system. Product Contents (deliverables):
-
i-B350L CC tag Associated Documents SDK Online Help i-SHARE Manual Specific reader manuals Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 7 i-B350L -CC Hardware User Manual | 20. September 2019 2. Introduction 2.1 General Information The ILR i-B350L CC active RFID broadcast tag transmits data over 500 meters in predetermined intervals. The credit card holder housing provides mounting possibilities for an ID card and is ideally suited for personnel safety applications. The i-B350L CC active RFID tag is ideally suited for industrial applications such as tracking, tracing and identification of assets and facility wide access and area control. Using advanced UHF radio frequency technology, the i-B350L CC tag transmits data up to 500 meters (1600 feet) to portable or fixed readers. With ultra-low power consumption and a configurable ping rate, the i-B350L CC tag can operate maintenance-free up to eight years. In combination with IDENTECs i-Mark RFID tag exciter, the i-B350L CC provides accurate localization for gates, zones, and lanes. The credit card housing is designed to be worn by personnel via necklace or in a pocket and provides mounting possibilities for an ID card. 2.2 System Components Tags The i-B350 series of tags are a state-of-the-art generation of active RFID tags. The tags provide highly accurate, real-time data collection without human intervention in wireless applications such as:
identification tracking and tracing localization and Measurements monitoring. Using advanced UHF radio frequency technology, i-B350L CC tags transmit and receive data at distances of up to 30 meters (100 feet) from a handheld device or up to 500 meters (1,640 feet) from a fixed reader. i-B350L CC The i-B350L CC tag includes a card holder for an ID card. The i-B350L CC tag operates in the 850 928 MHz UHF band. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 8 i-B350L -CC Hardware User Manual | 20. September 2019 System Components Readers 2.3 i-PORT M352 UHF i-PORT BT USB The i-PORT M352 UHF is used as a reader in Identecs system. It can be connected to the host PC software via several different interfaces (RS422, Ethernet, Power-over-Ethernet). It communicates with the ILR Tags wirelessly up to a distance of up to 500 meters. The battery powered mobile reader with Bluetooth and USB interface communicates with a wide spectrum of handheld devices and tablet computers. It is ideally suited for mobile applications such as laydown yards and personnel safety. With its integrated Bluetooth interface, the mobile reader can commu-
nicate with a wide range of mobile devices independent of platform or operating system. The compact and robust housing with internal antenna is designed to be mounted onto a handheld device or a tablet computer. The small form factor also allows users to carry the reader in a pocket. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 9 i-B350L -CC Hardware User Manual | 20. September 2019 2.4 System ComponentsAntennas Only approved antennas should be used. Other antennas not provided by IDENTEC SOLUTIONS may void permit of use and violate compliance regulations. Omnidirectional sub-1GHz Antenna Dimensions Half-wave Dipole Antenna Ordering number:
- 289070 Half-wave Dipole Antenna SMA i-CTA868 MHz (CTA 868/2/DR/SM/S2) Orientation Diagrams Elevation Azimuth Vertical Polarization Horizontal Polarization Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 10 i-B350L -CC Hardware User Manual | 20. September 2019 3. Configuration of the Tag 3.1 General The i-B350L CC is configured using the i-PROG M350L programming device. Important Note Do not open the housing! Configuration is done using the built-in air interface of the i-B350L CC. In addition to the Broadcast mode the i-B350L CC offers the following special functions that can be configured:
Bursts on entering a marker field can be configured independent from regular Pings Marker technology Bursts triggered by the push button can be configured independent from regular Pings Tools Needed PC running on MS Windows with the SensorSMART Tool software Connected to an i-PROG M350L to configure the tags Overview on the Configuration Software Select Ping Rate and Ping Message Content in the block Broadcast Select Burst behavior on entering a marker field in the block Marker 3.2 Ping Rate Note: This setting can be found in the ILR Tag Configuration software tool in the edit block Broadcast Broadcast Interval: 0 = no broadcast messages are sent, value > 0 = Broadcast interval in seconds. This can be set in steps of 0.5 sec, from 0.5 to 300 seconds. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 11 i-B350L -CC Hardware User Manual | 20. September 2019 Broadcast Message Options: The options in this field depend on the capabilities of the tag. User Data Length: Configure the number of Bytes from the User Data that is sent with a broadcast message. The number starts from Byte 0 (zero). Please pay attention to the limits of the User Data Length described at the end of this chapter. 3.3 Bursts when passing a Position marker Note: This setting can be found in the ILR Tag Configuration software tool in the edit block Marker Number of Bursts (New Loop): 0 = no bursts, max. 15 bursts Time between Bursts (Marker): This sets a timeslot inside which the tag sends out as single burst. This gives a random delay between every single burst message to avoid collisions with tags that are triggered by the same source to burst. Possible settings are 40, 100, 200, 300, 400, 500, 600, and 700 ms. Please read the details in the following subchapter Information on Burst Settings. Marker Message Options: Entering a marker field triggers a burst. This parameter determines the contents of the burst messages. 3.4 Limitations of the User Data Field The total length of the broadcast message (burst or ping) is limited to 50 Bytes. So depending on the broadcast message options, these are the allowed number of bytes for the user data:
User Data only => max. 50 Bytes of user data Marker | User Data => max. 38 Bytes of user data 3.5 Information of Burst Settling The parameter Time between Bursts (Marker) is not simply a delay time. It is in fact a timeslot. In this timeslot the tag chooses a random moment to do a single burst. This avoids that bursts collide with other tags, that are simultaneously triggered by the same marker loop. These timeslots are repeated until all bursts are sent. With very few tags the factory setting of 40 ms is sufficient. In case there is the possibility that dozens of tags are triggered to burst at once, this value can be increased. This brings the tradeoff of a longer overall time until all bursts are sent. E.g. with a slot width (Time between Bursts) of 700 ms and 8 bursts, the amount of time for all bursts is 5.6 seconds. Example This example shows 3 tags (A, B, C) that are simultaneously triggered by a marker loop (LF marker) and are configured to burst 3 times. The timeslot (Time between Bursts) is set to the default of 40 ms. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 12 i-B350L -CC Hardware User Manual | 20. September 2019 The last row shows how the random use of the timeslot avoids collision between the tags. Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 13 i-B350L -CC Hardware User Manual | 20. September 2019 4. Troubleshooting This chapter covers how faults can be recognized and rectified. There are potentially four main problem sources:
The user control system, including task requirements, communication cables, peripheral units with possible object recognition switches. The SensorSMART platform including peripheral units and their cables, also potential object recognition switches. The environment including large objects between antenna and ILR Tags, electrical disturbance sources, intervention by persons, etc. The quality of task requirements/available communication time etc. The information about system performance is contained in the relevant datasheets. including alignment between antenna, data, ratio of technical design, the When planning the total system, not overlook the problem sources and Fault finding procedures on system level should be included in the host system. How this could look in detail depends on the relevant system concept and very likely varies from one system to another. A Brief Checklist Are all housings intact?
Are all cables intact?
Are all connectors intact?
Are all connectors securely fastened?
Are all screws still tight?
Is there a sudden malfunction at a specific unit?
5. Maintenance When installed correctly the system will operate virtually maintenance free for many years. However, in the event maintenance is required, only trained and authorized personnel are permitted to perform the updates, changes and necessary maintenance. Regular Cleaning of the Surface Remove dust with a brush or compressed air. If the device has come in contact with greasy or oily substances use a soft cloth moistened with a mild rinsing agent. Do not use cleaning products containing chemical additives. Precautionary Maintenance A regular check of the system is recommended. Unstable connections could lead to damage and malfunctions of the system and should therefore be repaired as soon as possible. The firmware is stored in a FLASH memory and can be updated if needed. 5.1 Returns Parts or main components returned for repair or exchange must be handled with great care. All returns should include an error description and a short application overview and be sent to the local distributor or to:
IDENTEC SOLUTIONS AG Service Department Millennium Park 2 6890 Lustenau AUSTRIA Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 14 i-B350L -CC Hardware User Manual | 20. September 2019 6. Technical Specifications Communication - ILR350 technology Operation Mode Read Range Compatibility Operating Frequency Transmit Power Communication - Marker Operation Mode Read Range Compatibility Operating Frequency Data Identification Code Configuration Device Ping Rate Number of bursts Broadcast User Data Electrical Power Source Battery Monitoring Environmental Conditions Operating Temperature Humidity Shock:
Vibrations Standard/Certification Europe North America Mechanical Data Dimensions Enclosure Material Enclosure Rating Order Code i-B350L CC UHF Broadcast communication up to 500 m 1 i-PORT M350, i-PORT M352, i-PORT BT USB, iPOINT UHF ISM Band: 868 MHz (EU) or 920 MHz (NA)2
<1mW Receives Marker ID and transmits marker information via Broadcast
(350 telegrams) up to 5m (16ft)*
i-MARK S350, iPOINT 125 kHz 48-bit fixed ID i-PROG M350L Configurable from 0.5 to 300 seconds insteps of 0.5 seconds Configurable from 0 to 15 Up to 50 Bytes Lithium Battery (non-replaceable) Yes
-30C to +70C (-22F to +158 F) 10% to 95% relative humidity @ 30C EN 60068-2-32: Multiple drops to concrete from 1m (3ft), 5 times EN 60068-2-29: 50G on all 3 axis, 3 times per axis EN 60068-2-64: noise 5 to 1000Hz, 90 minutes per axis EN 60068-2-6: 5G, 20 sin wave cycles per axis, 5-500Hz CE (EN 300 220-1,-2,-3; EN 301 489-1,-3; EN 62368-1, EN 60950 FCC Part 15 (US); IC RSS210 104,5 x 58,4 x 12,0 mm (4.1 x 2.3 x 0.47 inches) Plastic (Luran S) light grey IP 52 455361 1 The communication range depends on environmental conditions and national regulation limits 2 Other country frequencies are available, please contact IDENTEC SOLUTIONS Copyright 2019 IDENTEC SOLUTIONS. All rights reserved. 15
This product uses the FCC Data API but is not endorsed or certified by the FCC